Image not available
Illustrative purposes only
6300-1000-0000
LCD COUNTER
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: TRUMETER
- Product type: Counters
- Digit Height: 8mm
- Panel Cutout Width: 45.5mm
- Supply Voltage Max: 30VDC
- Supply Voltage Min: 3VDC
- Panel Cutout Height: 22.6mm
- No. of Digits / Alpha: 8
- Operating Temperature Max: 60°C
- Operating Temperature Min: -20°C
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 41.19 € |
| Current stock | 10+ |
| Lead time | 30 days |
| | **Model 63** **Electronic** **LCD Hour Meter** ## **Description** The Model 63 Electronic Hour Meter with 8 LCD digits brings more features to the user than ever before. Models are available that are simple Hour Meters, while other models can bring together enough features to control a signifi cant process. A long list of features includes a programmable output, an external electronic reset, a front panel reset enable, and programmable alert or preset capability. In addition, the unit can be confi gured to operate from an external DC power supply or an internal 15+ year lithium battery. An EEPROM is available with the externally powered units to retain last data when power goes down. The front end of the Model 63 Hour Meter utilizes a high-contrast, refl ective, 8-digit LCD with 0.32 inch [8mm] digits and seven icons, while at the back end Dry Contact, Low Voltage DC, and High Voltage DC and AC Inputs are available. The Model 63 family is designed with a rugged plastic housing that is qualifi ed to NEMA 4/4X when properly installed in a panel using an optional gasket. In addition, the unit is compliant with CE EMC standards to EN61326:2001 for industrial applications, the unit is recognized by UL for U.S. and Canadian safety standards, and it is compliant to European RoHS and WEEE standards. ## **Features** • Refl ective LCD Display with 8 large (8mm) digits • Choice of four Hour Meter types • Hour Meter • Minute Meter • Seconds Meter • Dual hour Meter • Twin Hour Meter • Choice of I/O compliment that includes • One or two inputs • Switch Input (No voltage) • Low DC Voltage (3-30VDC) • High Voltage (20-300VAC or 10-300VDC) • Control Inputs • External Electronic Reset • Front Panel Reset Enable • Discrete Output • Open-Drain MOSFET • Choice of external power (with EEPROM) or internal 15+ year battery • Optional Front Panel Programming for fl exible Redi-Alert or Preset Hour Meter functionality • Optional Redi-Alert Functions • 3 Redi-Alerts are available with Front Panel Programming option • 4 Redi-Alerts are available with Factory Programming • Optional Preset Hour Meter Mode • Available with Front Panel Programming option or with Factory Programming • NEMA 4/4X, 12, and IP66 rated • EMC Compliant to EN61326:2001 for industrial environments • CE compliant, UL and cUL recognized • European WEEE & RoHS Compliant ## **Capabilities** ## **Hour Meter Operation** Any of four different counting methods may be specifi ed. These counting methods are factory set. Hour Meter: The Hour Meter displays hours in a resolution of hours and tenths. A front panel programmable unit or a factory programmed unit can be programmed to display a resolution of 0.01 hours. Minute Meter: The Minute Meter displays minutes to a displayed resolution of 0.1 minutes. Seconds Meter: The Seconds Meter displays seconds to a displayed resolution of 0.1 seconds. Dual Hour Meter: The Dual Hour Meter measures the time that Input A is at a high level in two accumulated times. One of the times can be reset, while the other cannot. The displayed times can be swapped on the display be pressing and releasing the SEL switch. The Dual Hour Meter is only available with the front panel programming option. Twin Hour Meter: The Twin Hour Meter behaves as two Hour Meters in one package. One Hour Meter is enabled by Input A and the second is en abled by Input B. The displayed Hour Meters can be swapped by pressing and releasing the SEL switch. The Twin Hour Meter is only available with the front panel programming option. ## **I/O Functions** The I/O functions can be mixed and matched to maximize the functionality of the Hour Meter. There are three types of inputs that the Hour Meter can accept. The interfaces for each are factory set. The inputs can be - Switch – open circuit or switch closure - Low Voltage DC – Low input is less than 1VDC and High Input is 3 – 30VDC. **www.redingtoncounters.com** **13** **Electronic** **LCD Hour Meter** **Model 63** • High Voltage DC or AC – Low is less than 3VDC or 3VAC. A High Input is either 10 – 300VDC or 20-300VAC. For the Switch and Low Voltage DC Hour Meters, there are six screw terminals for all of the I/O. For the High Voltage Hour Meters, there are four screw terminals for the I/O. The combinations of the I/O and power supply are factory set. Enable Inputs: The enable inputs are those inputs that enable the accumulation of time. Remote Reset: When the remote reset is at a high level, the Hour Meter will reset. Front Panel Reset Enable: The Hour Meter will reset when the Front Panel Reset Enable is at a high level, and the Front Panel Reset Switch is pressed. The Hour Meter will not reset when the Front Panel Reset Enable is at a low level and the Front Panel Reset Switch is pressed. Output: The output is an open-drain MOSFET. The output is used when operating in the Preset Mode, and it can be optionally used when using Redi-Alerts. ## **Preset Function** Each Hour Meter may be placed in a preset operating mode. This mode can be programmed through the front panel for those units that have the front panel programming option. It may also be factory programmed. IT IS NOT RECOMMENDED THAT THE PRESET FUNCTION BE USED AT THE SAME TIME THAT ALERTS ARE ENABLED. Basically, a preset Hour Meter is an Hour Meter that times to a preset value and then turns on an output device. At some point, the output device is turned off, the Hour Meter is reset, and the process begins again. There are two things to determine. One is when and how to turn off the output device, and the second is when and how to reset the Hour Meter. The preset Hour Meters can be set up for either automatic reset or external (front panel or remote) reset. The outputs can be turned off by either time out or external reset. In addition to the output, an icon can be turned on when the output is turned on for a visual indication of the preset condition. ## **Alert Functions** The Model 63 Hour Meter can be programmed to operate as a maintenance device in which alerts notify the user of certain maintenance actions to be taken after accumulation of a predefined time. When the accumulated time equals the predefined alert value, an icon is illuminated on the display. When the alert is reset, the icon is turned off, but the accumulated time is not reset. There are two types of alerts. The first is a break-in alert. A break-in alert only occurs once at the start of unit operation. The second type of alert is recurring. A recurring alert occurs continuously at a predefined period. When tied to a break-in alert, the recurring alert will not begin its count until the break-in alert has occurred. The intervals for the recurring alert can be performed as start-to-start or end-to-start. A start-to-start interval count starts when the last alert is turned on. The end-to-start interval count starts when the last alert is turned off. The Model 63 Hour Meter can support three alerts using front panel programming and four alerts when factory programmed. IT IS NOT RECOMMEDED THAT THE PRESET FUNCTION BE USED AT THE SAME TIME THAT ALERTS ARE ENABLED. In both cases, Alert #1 is a break-in alert that is tied to Alert #2, which is recurring. Alert #3 is recurring, and Alert #4 can be factory set as either break-in or recurring. If Alert #4 is break-in, then it is tied to Alert #3. The Model 63 Hour Meter can be programmed to be latched or kept on for a predetermined time. When latched, an external reset is required to turn off the alert. Each alert can also force the output on when the alert is on. ## **Front Panel** The liquid crystal display is reflective with dark characters on a light background. There are 8 digits on the display. The standard display contains seven icons which can be assigned as desired to either alerts or a preset. Model 63 Hour Meters with the front panel programming option are capable of being programmed for either alerts or the preset function. There are two front panel switches. To begin programming, the two switches are pressed simultaneously. The programming menu must be completed in its entirety to return to normal operation. The switch functions are described as follows: SEL: During normal operation, the displayed Hour Meters will be swapped when the SEL switch is pressed and released. During programming, this switch is used to select options. RST: During normal operation, the RST switch is used for front panel reset. During programming, the RST switch is used to enter an option. ## **Resets** Unless using alerts, a reset returns the display to zero. If using alerts, the reset turns an alert off. There are three different reset configurations available: Non-Reset: The Hour Meter can never be reset. A non-reset unit also has no front panel programming option. Remote Reset: A model with Remote reset has a dedicated terminal for performing the reset function. The unit resets when the remote reset signal is at a high level. When the reset signal is at a low level, accumulating time can occur. Manual Reset: Manual reset occurs when the RST switch on the front of the Hour Meter is pressed. Accumulating time resumes upon release of the RST switch. The exception to this operation is in the Dual Hour Meter case; the non-resettable Hour Meter can not be reset. Note: Some Hour Meters are equipped with a Manual Reset Enable Input. In this case, the Manual Reset Enable Input must be high for the RST switch to be functional. **www.redingtoncounters.com** **14** aD ~~MO~~ **Model 63 Electronic LCD Hour Meter** ## **Sp** **Display:** Figures: 8 LCD digits 0.32” [8mm] high Annunciators Icon: A choice of 7 Icons 0.08” [2mm] high **Reset:** Remote, manual & non-reset. Manual reset enable is available on some models **Speed:** Low speed: 0-40 counts per second (min. 12.5ms-on, 12.5ms-off High speed: 0-500 counts per second (min. 1.0 ms-on, 1.0 ms-off **Inputs:** Switch (no voltage) DC Voltage: Absolute voltage range: -0.5 VDC, minimum to 30.0VDC, maximum VIH: 3.0 VDC, maximum VIL: 1.0 VDC, minimum High Voltage AC/DC: Absolute Maximum voltage: 300VAC/VDC VIH: 10VDC/20 VAC, max. VIL: 3VDC/3 VAC, minimum **Power:** Internally powered models: Self powered (+15yrs lithium battery) Externally Powered models: 5-28 VDC , externally supplied Absolute Maximum external power: 30.0 VDC **Output:** Format: Open-Drain MOSFET with Source connected to Common (see note 3) Maximum Withstanding voltage: 30VDC, reference to Common Maximum Load current: 0.1Amp **EEPROM:** (When installed) 40 years Maximum data writes: 100,000 **Battery Life:** 15 years + **Mounting:** Panel with clip **Terminations:** Terminal block **Weight:** 2 oz. [57g] **Environmental:** Temp. (Storage & Operating): -4˚F to + 140˚F [-20˚C to +60˚C] Humidity: 0 to 95% RH, non-condensing **Vibration:** Operating: 10 to 55 Hz, 0.01” [0.25mm] double amplitude Non-operating: 10 to 55 Hz, 0.03” [0.75mm] double amplitude **Shock:** Operating: 10G’s Non-operating: 30G’s **Dielectric:** 1000 VAC 50/60Hz for 1 minute **Accuracy:** 100% (provided signal meets stated parameters) **EMC Compliance:** EN61326:1997 with A1: 1998 & A2:2001 for industrial environments **Enclosure:** NEMA 4/4X, 12, & IP66 compliance (from the front) when properly mounted using the optional gasket **Approvals:** CE compliant, UL & cUL recognized **Environmental Compliance:** Compliant to the European WEEE & RoHS ## **Notes** 1. When interfacing the Model 63 with a Solid State Relay or AC Sensor, the leakage current needs to be considered. Contact the factory or see the application note at www.redingtoncounters.com for further information. 2. The Absolute Voltage Range and the Absolute Maximum Voltage are the voltages at which operation beyond the specified limits may result in damage to the unit. 3. Operates like open-collector NPN. Care should be taken when interfacing to this input since there is no current limiting protection. ## **Dimensions** **==> picture [461 x 244] intentionally omitted <==** **----- Start of picture text -----**<br> 1.76 [44.7]<br>1.86 [47.3]<br>1.50 [38.0]<br>2.00 [50.8]<br>ee<br>Oe 1.31 [33.4] -_<br>.87 [22.1] .97 [24.7]<br>+ AA<br>.31 [8.0]<br>1.10 [27.9]<br>cea ome |<br>.02 [0.5]<br>.48 [12.1] .16 [4.0]<br>Panel Cutout: 1.79” [45.5mm] x 0.89” [22.6mm]<br>Recommended Panel Thickness: 0.875” [22.2mm]<br>SERVICE OIL AIR FILTER MUFFLER<br>CHANGE OIL FILTER LAMP<br>**----- End of picture text -----**<br> ## **Available Icons** **www.redingtoncounters.com** **15** |||**REDINGTON MODEL 63**<br>**PART NUMBER MATRIX**|**REDINGTON MODEL 63**<br>**PART NUMBER MATRIX**|**REDINGTON MODEL 63**<br>**PART NUMBER MATRIX**|**REDINGTON MODEL 63**<br>**PART NUMBER MATRIX**|**REDINGTON MODEL 63**<br>**PART NUMBER MATRIX**|| |---|---|---|---|---|---|---|---| |**Function/**||**Input**|||**Reset**||**Stock**| |**Application**||**3-30VDC**|**10-30VDC or 20-300VAC**|**Switch**|**Remote**|**Manual***|**Part Numbers****| |**Totalizer** (8 fig.)|40/500 cps|||�|�||**6300-0000-0000**| |||||�||�|**6300-0500-0000**| |||�|||�||**6300-1000-0000**| |||�||||�|**6300-1500-0000**| ||||�||�||**6301-2000-0000**| ||||�|||�|**6300-2500-0000**| |**Hour Meter**(8 fig.)|**Hours**|||�|�||**6320-0000-0000**| |||||�||�|**6320-0500-0000**| |||�|||�||**6320-1000-0000**| |||�||||�|**6320-1500-0000**| ||||�||�||**6320-2000-0000**| ||||�|||�|**6320-2500-0000**| ||**Minutes**|||�|�||**6321-0000-0000**| |||||�||�|**6321-0500-0000**| |||�|||�||**6321-1000-0000**| |||�||||�|**6321-1500-0000**| ||||�||�||**6321-2000-0000**| ||||�|||�|**6321-2500-0000**| ||**Seconds**|||�|�||**6322-0000-0000**| |||||�||�|**6322-0500-0000**| |||�|||�||**6322-1000-0000**| |||�||||�|**6322-1500-0000**| ||||�||�||**6322-2000-0000**| ||||�|||�|**6322-2500-0000**| |**Tach.**|(4 fig.)|||�|||**6330-0000-0000**| |||�|||||**6330-1000-0000**| ||||�||||**6330-2000-0000**| |�<br>�<br>�|**_All Stock Part Numbers are:_**<br>_Panel Mount (1.79" x .89")_<br>_Self-Powered (15yr lithium battery)_<br>_Terminal Block Termination_||||_alert features, outputs, etc._<br>**_**This product can be customized_**<br>**_to meet any application._**<br>_Contact Redington for optional_|||
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →