Image not available
Illustrative purposes only
61/BM2030
Circuit Breaker, Starbreaker B Curve Series, 240 V, 20 A, 2 Pole
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CRABTREE
- Product type:
- SVHC: To Be Advised
- No. of Poles: 2 Pole
- Product Range: Starbreaker B Curve Series
- Current Rating: 20A
- Overload Current: -
- Insulation Voltage: -
- Voltage Rating VAC: 240V
- Voltage Rating VDC: -
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 37.9 € |
| Current stock | 10+ |
| Lead time | 30 days |
## Miniature ## RCBOs & MCBs (for domestic household premises & similar installations) Starbreaker Devices ## **CRABTREE MINIATURE RCBOs** A range of Starbreaker plug in, MCB sized RCBOs for use in domestic household premises and similar installations. Starbreaker miniature RCBOs bring higher levels of safety to an electrical installation and its users because they include switched neutral as standard and bring cost savings by reducing installation and testing times. ## **Safer installations means safer homes** Starbreaker Miniature RCBOs with switched neutral built in as standard will fully isolate a faulty or damaged circuit by disconnecting live and neutral conductors. Using Starbreaker Miniature RCBOs will guarantee that healthy circuits remain in service and that only a faulty circuit is switched off. This avoids danger and prevents inconvenience in the event of a ***** fault (as required by regulation 314.1) . Miniature RCBOs take up less space in the consumer unit and so provide more wiring space for the installer, making the installation process easier and quicker. Starbreaker RCBOs go one step further, they have switched neutral built in as standard, live and neutral conductors do not have to be disconnected for insulation resistance testing. This saves time and money, particularly for responsible landlords who regularly test installations during occupancy voids. **ACTUAL SIZE** *** BS 7671 IET Wiring Regulations** ## Starbreaker miniature RCBOs & circuit breakers MINIATURE RCBO (MCB sized 1 module with switched neutral) MINIATURE CIRCUIT BREAKERS (6kA) |CURRENT RCD|CURRENT| |---|---| |B CURVE C CURVE RATING RATING POLES MODULES|B CURVE C CURVE RATING POLES MODULES| |61/BM0630 61/CM0630 6A 30mA 2 1|61/B06 61/C06 6A 1 1| |61/BM1030 61/CM1030 10A 30mA 2 1|61/B10 61/C10 10A 1 1| |61/BM1630 61/CM1630 16A 30mA 2 1|61/B16 61/C16 16A 1 1| |61/BM2030 61/CM2030 20A 30mA 2 1|61/B20 61/C20 20A 1 1| |61/BM2530 - 25A 30mA 2 1|61/B32 61/C32 32A 1 1| |61/BM3230 61/CM3230 32A 30mA 2 1|61/B40 61/C40 40A 1 1| |61/BM4030 61/CM4030 40A 30mA 2 1|61/B50 61/C50 50A 1 1| • Type A - Pure AC and pulsating DC sensitivity Starbreaker miniature RCBOs and circuit breakers for use in the Consumer Units as shown below **• Miniature RCBO for maximum wiring space** **• Quicker & easier to install** - **Saves time & money on testing, no need to disconnect circuit cables** - **Switched neutral built in as standard, fully isolates faults** - **Guarantees healthy circuits remain in service** - **Instant guaranteed plug in connections** - **Fully insulated busbar with permanent shields** **==> picture [483 x 517] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |a|MODEL|RCBO MCB| |Product brand name Starbreaker Starbreaker| |Product designation RCD operated circuit breaker Miniature circuit breaker| |GENERAL TECHNICAL DATA| |Number of poles 2 1| |Number of poles / Note 1P+N 1P| |Number of poles / with protection 1 1| |Tripping characteristics class B or C B or C| |RCD type A -| |Mechanical service life (switching cycles) / typical 10,000 -| |Overvoltage category III 3| |a|PRODUCT FUNCTION| |Product function / neutral conductor switching Yes N/A| |VOLTAGE| |Surge current resistance / at (8/20) µs 1kA N/A| |SUPPLY VOLTAGE| |• at AC / rated value 240V 250V| |• for testing equipment / minimum 195V -| |Supply voltage frequency / rated value 50Hz 50Hz| |PROTECTION CLASS| |Protection class IP IP20 IP20| |Energy limiting class 3 3| |a|SWITCHING CAPACITY CURRENT| |• acc. to EN 60898 / rated value 6kA 6kA| |a|DISSIPATION| |Power loss (W)| |• for rated value of the current / at AC / in hot operating state / per pole 1.5W 2.6W| |• maximum 2.6W 2.6W| |a|ELECTRICITY| |Tripping residual current / rated value 30mA N/A| |Rated current in / IEC, DIN/VDE / at 40 cel 9.4A 15.08A| |Current / at AC / rated value 6A - 40A 6A - 50A| |CONNECTIONS| |Connectable conductor cross-section / stranded| |• minimum 0.75mm|[2 ]|0.75mm|[2]| |• maximum 16mm|[2 ]|25mm|[2]| |Connectable conductor cross-section| |• solid - minimum 0.75mm|[2 ]|0.75mm|[2]| |• solid - maximum 16mm2 25mm2| |• finely stranded / with core end processing - minimum 0.75mm2|0.75mm2| |a|TIGHTENING TORQUE / WITH SCREW-TYPE TERMINALS| |Load terminal| |• minimum 1.2Nm|2.3Nm| |• maximum 2.0Nm|3.0Nm| |a|MECHANICAL DESIGN| |Height x Width x Depth 90mm x 18mm x 77mm 90mm x 18mm x 77mm| |Mounting|position Any Any| |Installation depth 70mm 70mm| |Number of width units 1 1| |Net weight 130g - 168g 116g - 156g| |ENVIRONMENTAL CONDITIONS| |Degree of pollution 2 2| |Influence of the surrounding temperature Maximum 95% humidity Maximum 95% humidity| |Ambient Temperature| |• minimum -25ºC -25ºC| |• maximum 55ºC 45ºC| |• during storage / minimum -40ºC -40ºC| |• during storage / maximum 75ºC 75ºC| **----- End of picture text -----**<br> ## ELECTRIUM SALES LIMITED A SIEMENS COMPANY Commercial Centre, Lakeside Plaza, Walkmill Lane, Bridgtown, Cannock WS11 0XE. eMail: info@electrium.co.uk Web: www.electrium.co.uk UK SALESTelephone: 01543 455010 Facsimile: 01543 455011 eMail: crabtree.sales@electrium.co.uk TECHNICALTelephone: 01543 438310 Facsimile: 01543 438311 eMail: crabtree.technical@electrium.co.uk EXPORT SALESTelephone: +44 1543 455049 Facsimile: +44 1543 455048 eMail: export@electrium.co.uk DUBAI OFFICE Telephone: +971 4 3660687 Facsimile: +971 4 3660676 eMail: btlv.sales.ae@siemens.com Although every effort has been made to ensure accuracy in the compilation of the technical detail within this publication, specifications and performance data are constantly changing. Latest details can be obtained from Crabtree. Publication No. B2380 10/17 Printed in England. @ElectriumNews or download the APP
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →