- Manufacturer: SIEMENS
- Product type:
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 363.66 € |
| Current stock | 10+ |
| Lead time | 30 days |
**5TT5200** **Data sheet** EMERGENCY OFF relay T55 230V 10A Overall depth 55 mm ||EMERGENCY OFF relay T55 230V 10A Overall depth 55 mm| |---|---| |**Model**<br>~~ees~~|| |**product brand name**<br>~~ees~~|SENTRON<br>~~ees~~| |**product category**|basic device| |**product designation**|EMERGENCY-OFF relay| |**design of theproduct**|Mountingdepth 55 mm| |**design of input feedback input**|Yes| |**design of input start input**|Yes| |**General technical data**<br>~~ees~~|| |**amplitude of deflection for vibration test according to IEC**<br>**60068-2-6 up to 55 Hz**<br>~~ees~~|0.35 mm<br>~~ees~~| |**operating range factor of control voltage_1**|0.8| |electrical endurance (operating cycles) of the contacts at 2 A at<br>AC-15 at 230 V|100 000| |**category according to EN 954-1**|4| |**determinants for climatic applicability according to IEC**<br>**60068-1**|0/55/04| |**performance level(PL) according to EN ISO 13849-1**|Level e| |**operating frequency maximum**|600 1/h| |**recovery time**|500 ms| |**Voltage**<br>~~ees~~|| |**SIL Claim Limit(subsystem) according to EN 62061**<br>~~ees~~|3<br>~~ees~~| |surge voltage resistance between contacts of the relay<br>operatingmechanism|4 kV| |**Breaking Capacity**<br>~~ees~~|| |**switching capacity voltage of the contacts**<br>~~ees~~|~~ees~~| |● as NC contact at DC-13|24 V| |● as NO contact at DC-13|24 V| |**switching capacity current of the contacts**|| |● as NC contact at AC-15|2 A| |● as NC contact at DC-13|4 A| |● as NO contact at AC-15|3 A| |● as NO contact at DC-13|4 A| |● as CO contact at AC-1|5 A| |**Dissipation**<br>~~ae~~|| |**power loss[V·A]**<br>~~ae~~|~~ae~~| |● of magnet coil in relayoperatingmechanism|3.5 VA| |● of the contact in relayoperatingmechanism|0.8 VA| |**Main circuit**<br>~~ees~~|| |operatingfrequencyrated value<br>~~ees~~|50 Hz<br>~~ees~~| |**Control current**<br>~~eee~~|| Subject to change without notice © Copyright Siemens 5TT5200 Page 1/4 6/4/2026 **==> picture [511 x 611] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |type of voltage of the control supply voltage|AC| |control voltage at connecting terminal Y1 at AC/DC|24 V| |control supply voltage at AC| |● rated value|230 V| |● at 50 Hz rated value minimum|184 V| |● at 50 Hz rated value maximum|253 V| |● at 60 Hz rated value minimum|184 V| |● at 60 Hz rated value maximum|253 V| |ee|control current at connecting terminal Y1 at DC|45 mA| |operating range factor of control voltage_2|1.1| |Suitability| |suitability for use safety switch|Yes| |suitability for use magnetically operated switch monitoring|No| |suitability for use proximity switch monitoring|No| |suitability for use EMERGENCY-OFF circuit monitoring|Yes| |suitability for use opto-electronic protection device|No| |monitoring| |suitability for use position switch monitoring|Yes| |SSS|suitability for use tactile sensor monitoring|No| |suitability for use valve monitoring|No| |Product function| |product function muting function|No| |||Number| |number of terminals with cross-head screw|1| |number of outputs as contact-affected switching element|4| |safety-related instantaneous contact| |||Connections| |type of connectable conductor cross-sections|2 × 2.5 mm² (rigid max.); 1 × 0.5 mm² (flexible, with end sleeve min.)| |type of electrical connection|screw terminal| |● plug-in socket|No| |||Mechanical Design| |height|90 mm| |width|71 mm| |width of opening of the contacts|1 mm| |depth|55 mm| |fastening method rail mounting|Yes| |required spacing between contacts of the relay operating|3 mm| |mechanism| |ee| |Net Weight|295 g| |Environmental conditions| |ambient temperature during operation| |● minimum|0 °C| |● maximum|50 °C| |ee|Approvals Certificates| |Environment|General Product Approval| |Environmental Con-|Environmental Con-|TUEV|Confirmation| |firmations|firmations| |—|——|FAME| **----- End of picture text -----**<br> ## **other** Confirmation **Further information** ~~OO—CSC“‘CNC;CéiésCs~~ 5TT5200 Subject to change without notice Page 2/4 6/4/2026 © Copyright Siemens Subject to change without notice © Copyright Siemens ## **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/lowvoltage/catalogs **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=5TT5200 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/5TT5200 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)** https://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=5TT5200 **CAx-Online-Generator** https://www.siemens.com/cax **Tender specifications** https://www.siemens.com/specifications **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **==> picture [370 x 206] intentionally omitted <==** **----- Start of picture text -----**<br> 60,1<br>71,6 54,8<br>89,9<br>**----- End of picture text -----**<br> **last modified:** 5/26/2025 Subject to change without notice © Copyright Siemens 5TT5200 Page 3/4 6/4/2026 Subject to change without notice © Copyright Siemens 5TT5200 Page 4/4 6/4/2026
Updated at March 31, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →