562113
P.BE-MPA-ELEKTRONIK-EN DESCRIPTION
- Manufacturer: FESTO
- Product type: Controller Accessories
- SVHC: No SVHC (25-Jun-2020)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 57.36 € |
| Current stock | 10+ |
| Lead time | 30 days |
# **Valve terminals MPA-F** -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features ## **Reliable** ## **Versatile** ## **Innovative** ## **Easy to mount** ~~e~~ Manifold blocks, tubing connec ~~e~~ Modular system offering a range of Sturdy and durable metal Tested and ready to install unit tions and exhausts designed for configuration options components Lower selection, ordering, installa optimum flow rates e Expandable up to 128 solenoid – Valves tion and commissioning costs e Tubing diameters: coils – Manifold blocks e Secure mounting on wall or H-rail – Conversions and extensions – Seals Further manifold blocks can be as - Working ports up to 10 mm – Seals Further manifold blocks can be as e Fast troubleshooting thanks to LEDs sembled using just two screws and on the valves and diagnostics via sturdy separating seals on metal Conversions and extensions possible at a later date Fast troubleshooting thanks to LEDs on the valves and diagnostics via fieldbus - Supply ports up to 16 mm - ee MPAF2 flow rates up to 900 l/min Selectable pilot air supply Selectable pilot air supply Integration of innovative function modules possible - e Valve terminal with multi-pin plug e and fieldbus connections and separator plates Extensive operating voltage range - control block Manual pressure regulators, - 25% rotatable pressure gauges Easy to service through replaceable Dream team: fieldbus valve ee - terminal suitable for CPX electrical e Pressure sensors integrated valves and electronics modules on the valve terminal Manual override either non-detent e Manual override either non-detent - peripherals. This means: - Forward-looking internal com munication system for controlling the valves and CPX modules Additional air supply via additional ing, detenting or secured against unauthorised activation (covered) Durable, thanks to tried and tested spool valves - e pressure zones using supply plates - e Wide range of pressures e Durable, thanks to tried and tested - –0.9 … 10 bar - Diagnostics down to the individual valve Large, durable and comprehensive labelling system Wide range of valve functions - ee - Valves can be actuated with or without (standard) isolated electrical circuits > **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 2 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features Reduced downtimes: Two-colour LED diagnostics on-site Width 10 mm and 20 mm Pneumatic interface to CPX with optional integrated pressure sensor Simple electrical connections – Multi-pin plug connection – Fieldbus connection - Control block CPX diagnostic interface for hand held devices (channel-oriented diag nostics down to the individual valve) Quick mounting: Directly using screws or on an H-rail, automatic earthing Safe: **==> picture [73 x 53] intentionally omitted <==** **==> picture [242 x 234] intentionally omitted <==** **----- Start of picture text -----**<br> Reliable operation:<br>Manual override: non-detenting/detenting or covered<br>Flexible:<br>–<br>64 valve positions/128 solenoid coils (FB)<br>–<br>24 valve positions/24 solenoid coils (MP)<br>Functional:<br>Sturdy metal thread or pre-assembled<br>QS fittings<br>Modular:<br>Supply plates facilitate the creation<br>of multiple pressure zones as well as<br>numerous additional exhaust and<br>supply ports<br>Wide range of valve functions<br>**----- End of picture text -----**<br> Operating voltage connection 25%, outputs and valves can be disconnected separately ## **Equipment options** Valve functions - 5/2-way valve, single solenoid - 5/2-way valve, double solenoid - 2x 3/2-way valve, normally open - � 2x 3/2-way valve, normally closed - 2x 3/2-way valve, 1x normally open, 1x normally closed - 5/3-way valve, mid-position pressurised - 5/3-way valve, mid-position closed - 5/3-way valve, mid-position exhausted - 2x 2/2-way valve, 1x normally closed, 1x normally closed, reversible - 2x 2/2-way valve, normally closed - 1x 3/2-way valve, normally closed, external compressed air supply - 1x 3/2-way valve, normally open, external compressed air supply - Manual pressure regulators - All valves have the same compact dimensions with an overall length of 107 mm and a width of 10.5 mm or 21 mm. A height of 55 mm makes them a perfect match for the electrical peripherals CPX. - Pressure sensors can be integrated Special features ## **Multi-pin plug terminal** - Max. 24 valve positions/ max. 24 solenoid coils - Parallel modular valve linking via circuit boards - Electronics module with integrated holding current reduction - Any compressed air supply ## **Fieldbus terminal/control block** - Max. 64 valve positions/ max. 128 solenoid coils - Internal CPX bus system for valve actuation - Module for electrical valve actuation, with or without isolated electrical circuits - Any compressed air supply - Creating pressure zones - Electrical module with extended diagnostics - Short circuit detection - Open load detection - – Condition counter ## **Combinable** - MPAF1 flow rates of up to 360 l/min - MPAF2 flow rates of up to 900 l/min - MPAF1 and MPAF2 can be combined on one valve terminal - Creating pressure zones Electrical supply plate - Increases the maximum number of valve positions possible to 64, with max. 128 solenoid coils - Creation of isolated, individually disconnectable electrical circuits (voltage zones) - Greater economy thanks to the higher number of valves/solenoid coils per valve terminal - Greater safety through individual disconnection of valve groups, for example for EMERGENCY-STOP functions Note -H- The electrical supply plate is available with either an M18 or 7/8” connection. � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 3 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features **==> picture [488 x 435] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |Valve terminal configurator|Online via:|� www.festo.com| |The appropriate MPA-F valve terminal|The valve terminals are fully|The valve terminal MPA-F is ordered| |can be chosen quickly and easily|assembled according to your order|using the order code.| |using the online catalogue. This in|specification and are individually| |cludes an easy-to-use valve terminal|tested. This reduces assembly and|Ordering system for MPA-F| |configurator. This makes it much|installation time to a minimum.|� Internet: mpaf| |easier to find the right product.|Ordering system for CPX| |� Internet: cpx| |Multi-pin plug connection| |The signal flow from the controller to|The valve terminal can be equipped|Versions| |the valve terminal takes place via a|with max. 24 solenoid coils. This|�|Sub-D connection| |pre-assembled or self-assembled|corresponds to 4 to 24 MPA1 or 2 to|�|Pre-assembled multi-pin cable| |multi-wire cable to the multi-pin plug|24 MPA2 valves, or a combination of|�|Multi-pin cable for self-assembly| |connection, which substantially|both.| |reduces installation time.| |Fieldbus connection via the CPX system| |An integrated fieldbus node manages|Valve terminals with fieldbus inter|Versions| |communication with a higher-order|faces can be configured with up to|�|PROFIBUS DP| |PLC. This enables a space-saving|16 manifold blocks. In conjunction|�|INTERBUS| |pneumatic and electronic solution.|with MPAF1 and 8 solenoid coils per|�|DeviceNet| |manifold block, up to 128 solenoid|�|CANopen| |coils can thus be actuated. An MPAF2|�|CC-Link| |with 4 solenoid coils per manifold|�|EtherNet/IP| |block can actuate 64 solenoid coils.|�|PROFINET| |�|POWERLINK| |�|EtherCAT| |�|Sercos III| |�|Front End Controller Remote| |�|Front End Controller| |Remote I/O| |�|Modbus/TCP| |�|CPX terminal| |� Internet: cpx| **----- End of picture text -----**<br> ## **Control block connection via the CPX system** **==> picture [43 x 33] intentionally omitted <==** Controllers integrated in the Festo valve terminals enable the construc tion of stand-alone control units to IP65, without control cabinets. Using the slave operation mode, these valve terminals can be used for intelli gent pre-processing and are therefore ideal modules for designs using decentralised intelligence. In the master operation mode, valve terminal groups can be designed with many options and functions, which can autonomously control a medium sized machine/system. � CPX terminal � Internet: cpx � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 4 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features ## **CP string extension** **==> picture [66 x 63] intentionally omitted <==** The optional string extension enables additional valve terminals and I/O modules to be connected to the fieldbus node of the CPX terminal. Different input and output modules as well as valve terminals can be connected. The maximum length of the CP string extension is 10 metres, which means that the extension modules can be mounted directly on-site. All of the required electrical signals are trans mitted via the CP cable, which in turn means that no further installation is needed on the extension module. The CP string interface offers: - 32 input signals - 32 output signals for output modules 24 V DC or solenoid coils - Logic and sensor supply for the input modules - Load voltage supply for the valve terminals - Logic supply for the output modules � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 5 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Peripherals overview ## **Modular pneumatic components** The modular design of the MPA-F facilitates maximum flexibility right from the planning stage and offers maximum ease of servicing during operation. The system consists of manifold blocks and valves. The manifold blocks are screwed together and thus form the support system for the valves. **==> picture [118 x 60] intentionally omitted <==** They contain the connection ducts for supplying compressed air to and vent ing from the valve terminal as well as the working lines for the pneumatic drives for each valve. **==> picture [112 x 81] intentionally omitted <==** Each manifold block is connected to the next using three screws. Individual terminal sections can be isolated and further manifold blocks inserted by loosening these screws. This ensures that the valve terminal can be rapidly and reliably extended. **==> picture [54 x 65] intentionally omitted <==** ## **Modular electrical peripherals** The manner in which the valves are Serial linking facilitates the following: actuated differs according to whether � Transmission of switching you are using a multi-pin terminal or information fieldbus terminal. � High valve density The MPA-F with CPX interface is based � Compact design on the internal bus system of the CPX � Position-based diagnostics and uses this serial communication system for all solenoid coils and a range of electrical input and output functions. ## MPA-F with electrical peripherals CPX **==> picture [81 x 58] intentionally omitted <==** - Separate voltage supply for valves � CPX-FEC as autonomous controller - � Flexible conversion without address with access via Ethernet and web shifting server - � Transmission of status, parameter and diagnostic data � Internet: cpx Modularity with electrical peripherals CPX **==> picture [39 x 40] intentionally omitted <==** � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 6 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Peripherals overview ## **Valve terminal pneumatics** - The manifold blocks are either � Valve positions for two solenoid � Valve positions for one solenoid prepared for: coils can be equipped with any coil can only be equipped with � 2 or 4 valves with one solenoid coil valve or a blanking plate. valves of this type (e.g. 5/2-way � 2 or 4 valves with two solenoid valve, single solenoid). - 2 or 4 valves with two solenoid coils **==> picture [478 x 427] intentionally omitted <==** **----- Start of picture text -----**<br> aC aD<br>aB<br>aJ<br>aE<br>9<br>8<br>aA<br>5<br>4<br>3<br>6<br>7<br>aF<br>aG<br>2<br>aF<br>aH<br>aI<br>1 aF<br>bJ<br>bA<br>bB<br>bC<br>bD aF<br>**----- End of picture text -----**<br> � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 7 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Peripherals overview |**Valve terminal pneumatics**||| |---|---|---| |Designation|Brief description|�**Page/Internet**| |1<br>Electronics module|For connectingMPA1 or MPA2 valves|53| |2<br>Regulatorplate|Width 10 mm|51| |3<br>Solenoid valve|Width 10 mm|50| |4<br>Cover cap for manual override|Conversion from detenting/non-detenting to non-detenting or covered|–| |5<br>Blanking plate|For unused valveposition (vacantposition), width 10 mm|54| |6<br>Verticalpressure shut-offplate|The relevant solenoid valve can be switched to unpowered and changed duringoperation|51| |7<br>Electrical interlinkingmodule|For fieldbus connection|53| |8<br>Exhaust plate|For ducted exhaust air (port 3/5 combined)|54| |9<br>Exhaustplate|For ducted exhaust air (port 3/5 separate)|54| |aJ<br>Flatplate silencer|–|55| |aA<br>Mountingbracket|Optional for valve terminal mounting|53| |aB<br>Regulatorplate|Size 20 mm|51| |aC<br>Solenoid valve|Size 20 mm|50| |aD<br>Blanking plate|For unused valveposition (vacantposition), width 20 mm|54| |aE<br>H-rail mounting|–|53| |aF<br>Fittings|–|54| |aG<br>Right-hand end plate|–|52| |aH<br>Manifold block|For two valve locations, width 20 mm|52| |aI<br>Separatingseal|For manifold block|54| |bJ<br>Supply plate|–|54| |bA<br>Pressure sensor|–|52| |bB<br>Electrical supply plate|For additional power supply for large valve terminals (only with fieldbus)|52| |bC<br>Electrical interlinkingmodule|For multi-pinplugconnection|53| |bD<br>Manifold block|For four valve locations, width 10 mm|50| � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 8 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Peripherals overview ## **Valve terminal with multi-pin plug connection** - Order code: MPA-F valve terminals with multi-pin � 33P-… for the pneumatic plug connection can be expanded by components up to 24 solenoid coils. - 33E-… for the electrical components - The multi-pin plug connection is de signed as a removable 25-pin Sub-D connection to IP65. The cable can be selected when ordering: - 2.5 m - 5 m - 10 m - Each can be used for max. 8 or 24 valves. **==> picture [342 x 360] intentionally omitted <==** **----- Start of picture text -----**<br> 1 2 3 4<br>6 5<br>**----- End of picture text -----**<br> |Designation|Brief description|�**Page/Internet**| |---|---|---| |1<br>Inscription labels|Large, for multi-pinplugconnection|–| |2<br>Flatplate silencer|Forpneumatic interface|55| |3<br>Exhaust plate|For ducted exhaust air (port 3/5 separate)|54| |4<br>Exhaustplate|For ducted exhaust air (port 3/5 combined)|54| |5<br>Electrical interface|For multi-pinplug|52| |6<br>Multi-pinplugconnection|With multi-pin cable|53| � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 9 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Peripherals overview - **Valve terminal with fieldbus connection, control block (electrical peripherals CPX)** - Order code: Valve terminals with fieldbus inter Each valve position can be equipped � Digital inputs/outputs � 33P-… for the pneumatic faces can be configured with up to with any valve or a blanking plate for � Analogue inputs/outputs components 16 manifold blocks. In conjunction future extensions. The rules for CPX � Parameterisation of inputs and - � 50E-… for the electrical with MPAF1 and 8 solenoid coils per apply to the equipment that can be outputs components manifold block, up to 128 solenoid used in combination with the � Integrated convenient diagnostic coils can thus be actuated. An MPAF2 electrical peripherals CPX. system with 4 solenoid coils per manifold � Preventive maintenance concepts block can actuate 64 solenoid coils. 3 - 2 - 1 - 6 4 - 5 |Designation<br>Bri|Designation<br>Bri|ef description|�**Page/Internet**| |---|---|---|---| |1|Exhaustplate<br>For|ducted exhaust air (port 5/3 combined)|54| |2|Exhaust plate<br>For|ducted exhaust air (port 5/3 separate)|54| |3|Flatplate silencer<br>For|pneumatic interface|55| |4|Endplate<br>Pne|umatic interface for CPX modules|52| |5|Electrical interface<br>CPX|module|–| |6|Inscription label<br>Lar|ge, for endplate|–| � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 10 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components ## **Sub-base valve** MPA-F offers a comprehensive range of valve functions. All valves are equipped with patented sealing sys tem which facilitates efficient sealing, a broad pressure range and long service life. They have a pneumatic pilot control for optimising perform ance. Air is supplied by means of pilot air supply. Sub-base valves can be quickly replaced since the tubing connectors remain on the manifold block. This design is also particularly flat. Irrespective of the valve function there are sub-base valves with one solenoid coil (single solenoid) or with two sole noid coils (double solenoid or two single solenoid valves in one housing). ## **Constructional design** Valve replacement Extension The valves are attached to the metal replaced. The mechanical sturdiness Blanking plates can be replaced by manifold block using two screws, of the manifold block guarantees valves at a later date. The dimensions, which means that they can be easily excellent long-term sealing. mounting points and existing pneu matic installations remain unchanged during this process. The valve code (M, MS, MU, J, N, NS, NU, K, KS, KU, H, HS, HU, B, G, E, X, W, D, DS, I) is located on the front of the valve beneath the manual override. |**/2-way valve**|**/2-way valve**||| |---|---|---|---| |ode<br>Circu|it symbol|Width|Description| |||[mm]|| |||10,<br>20|�Single solenoid<br>�Pneumatic spring return<br>�Reversible<br>�Operating pressure –0,9…+10 bar| |S||10,<br>20|�Single solenoid<br>�Mechanical spring return<br>�Reversible<br>�Operating pressure –0,9…+8 bar| |U||10|�Single solenoid<br>�Polymer poppet valve<br>�Mechanical spring return<br>�Reversible<br>�Operating pressure –0,9…+10 bar| |||10,<br>20|�Double solenoid<br>�Reversible<br>�Operating pressure –0,9…+10 bar| � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 11 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components |**2x 3/2-way valve**|**2x 3/2-way valve**|||| |---|---|---|---|---| |Code|Circuit symbol||Width|Description| ||||[mm]|| |N|||10,<br>20|�Single solenoid<br>�Normally open<br>�Pneumatic spring return<br>�Operating pressure 3 … 10 bar| |NS|||10,<br>20|�Single solenoid<br>�Normally open<br>�Mechanical spring return<br>�Reverse operation<br>�Operating pressure –0.9 … +8 bar| |NU|||10|<br>�Single solenoid<br>�Polymer poppet valve<br>�Normally open<br>�Mechanical spring return<br>�Reverse operation<br>�Operating pressure –0.9 … +10 bar| |K|||10,<br>20|�Single solenoid<br>�Normally closed<br>�Pneumatic spring return<br>�Operating pressure 3 … 10 bar| |KS|||10,<br>20|�Single solenoid<br>�Normally closed<br>�Mechanical spring return<br>�Reverse operation<br>�Operating pressure –0.9 … +8 bar| |KU|||10|�Single solenoid<br>�Polymer poppet valve<br>�Normally closed<br>�Mechanical spring return<br>�Reverse operation<br>�Operating pressure –0.9 … +10 bar| |H|||10,<br>20|�Single solenoid<br>�Normal position<br>– 1x closed<br>– 1x open<br>�Pneumatic spring return<br>�Operating pressure 3 … 10 bar| |HS|||10,<br>20|�Single solenoid<br>�Normal position<br>– 1x closed<br>– 1x open<br>�Mechanical spring return<br>�Reverse operation<br>�Operating pressure –0.9 … +8 bar| |HU|||10|�Single solenoid<br>�Polymer poppet valve<br>�Normal position<br>– 1x closed<br>– 1x open<br>�Mechanical spring return<br>�Reverse operation<br>�Operating pressure –0.9 … +10 bar| � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 12 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components |**5/3-way valve**|||| |---|---|---|---| |Code|Circuit symbol|Width|Description| |||[mm]|| |B||10,<br>20|�Mid-position pressurised1)<br>�Mechanical spring return<br>�Reverse operation<br>�Operating pressure –0.9 … +10 bar| |G||10,<br>20|�Mid-position closed1)<br>�Mechanical spring return<br>�Reverse operation<br>�Operating pressure –0.9 … +10 bar| |E||10,<br>20|�Mid-position exhausted1)<br>�Mechanical spring return<br>�Reverse operation<br>�Operating pressure –0.9 … +10 bar| - 1) If neither solenoid coil is energised, the valve moves to its mid-position by means of spring force. If both coils are energised at the same time, the valve remains in the previously assumed switching position. |**3/2-way valve**||||| |---|---|---|---|---| |Code|Circuit symbol||Width|Description| ||||[mm]|| |W|||10,<br>20|�Single solenoid<br>�Normally open<br>�External compressed air supply<br>�Pneumatic spring return<br>�Reverse operation<br>�Operating pressure –0.9 … +10 bar<br>Compressed air (–0.9 … +10 bar) supplied at working port 2<br>can be switched with both internal and external pilot air supply.| |X|||10,<br>20|�Single solenoid<br>�Normally closed<br>�External compressed air supply<br>�Pneumatic spring return<br>�Reverse operation<br>�Operating pressure –0.9 … +10 bar<br>Compressed air (–0.9 … +10 bar) supplied at working port 4<br>can be switched with both internal and external pilot air supply.| � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 13 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components |**2x 2/2-way valve**|**2x 2/2-way valve**|**2x 2/2-way valve**||||||| |---|---|---|---|---|---|---|---|---| |Code|Circuit symbol||||||Width|Description| ||||||||[mm]|| |D|||||||10,<br>20|�Single solenoid<br>�Normally closed<br>�Pneumatic spring return<br>�Operating pressure 3 … 10 bar| |||||||||| |||||||||| |||||||||| |||||||||| |||||||||| |||||||||| |DS|||||||10,<br>20|�Single solenoid<br>�Normally closed<br>�Mechanical spring return<br>�Reverse operation<br>�Operating pressure –0.9 … +8 bar| |||||||||| |||||||||| |||||||||| |||||||||| |I|||||||10,<br>20|�Single solenoid<br>�1x normally closed<br>�1x normally closed, reverse operation<br>�Pneumatic spring return<br>�Operating pressure 3 … 10 bar<br>�Vacuum atport 3/5 only| |||||||||| |||||||||| |||||||||| |||||||||| Note -H- A filter must be installed upstream of valves operated in vacuum mode. This prevents any foreign matter in the intake air getting into the valve (e.g. when operating a suction cup). � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 14 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components ## **Vertical stacking** **==> picture [51 x 79] intentionally omitted <==** Additional function units can be ad ded to each valve position between the sub-base and the valve. These units are known as vertical functioning or control of an individual stacking modules and enable special valve position. ## Pressure regulator plate An adjustable pressure regulator can be installed between the sub-base and the valve in order to control the force of the triggered actuator. This pressure regulator maintains an Standard version: essentially constant output pressure � For supply pressure up to 6 bar or (secondary side) independent of up to 10 bar pressure fluctuations (primary side) � Without pressure gauge (optional) and air consumption. � Regulator knob with 3 positions (locked, reference position, free running) ## Vertical pressure shut-off plate for MPA1 The vertical pressure shut-off plate can be used to hot swap individual valves without switching off the overall air supply. It allows the working pressure for the individual valve to be switched off manually via the actuating element. � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 15 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components **==> picture [488 x 280] intentionally omitted <==** **----- Start of picture text -----**<br> Vertical stacking<br>Vertical stacking components, MPA1 Vertical stacking components, MPA2<br>1<br>1<br>2<br>2<br>3<br>3<br>4<br>5<br>**----- End of picture text -----**<br> - 1 Valve VMPA1 - 2 Valve VMPA1, mounting screws replaced by long version (included in the scope of delivery of the regulator plate) - 1 Valve VMPA2 - 2 Regulator plate VMPA2 - 3 Manifold sub-base - 3 Vertical pressure shut-off plate VMPA1-HS - 4 Regulator plate VMPA1 - 5 Manifold sub-base � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 16 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components ## **Vertical stacking** Mode of operation of pressure regulator plate (P regulator) for port 1; code: PA, PF This pressure regulator regulates the During venting, the exhaust flow in pressure upstream of the valve in the valve is from duct 2 to duct 3 and duct 1. Ducts 2 and 4 thus have the from duct 4 to duct 5. same regulated pressure. - Advantages Application examples - � The pressure regulator is not � The pressure regulator can always � An equal working pressure is � A lower working pressure affected by venting, since the be adjusted and read, since the required at working ports 2 and 4. (e.g. 3 bar) than the operating pres pressure is regulated upstream pressure from the valve terminal is sure present on the valve terminal of the valve. always present. (e.g. 8 bar) is required. Mode of operation of the pressure regulator plate (B regulator) for port 2; code: PC, PH This pressure regulator regulates the pressure in duct 2 after the pressure medium flows through the valve. During venting, the exhaust flow in the valve is from duct 2 to duct 3 via the pressure regulator. Restrictions The pressure regulator can only be ad is switched to 2 and exhaust flow is justed in switched state (e.g. the valve from 4 to 5). Application example Reduced pressure at port 2. Operating pressure at port 4. � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 17 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components ## **Vertical stacking** Mode of operation of the pressure regulator plate (A regulator) for port 4; code: PB, PK This pressure regulator regulates the pressure in duct 4 after the pressure medium flows through the valve. During venting, the exhaust flow in the valve is from duct 4 to duct 5 via the pressure regulator. Restrictions Application example The pressure regulator can only be ad is switched to 4 and exhaust flow is Reduced pressure at port 4. Operating justed in switched state (e.g. the valve from 2 to 3). pressure at port 2. Mode of operation of the pressure regulator plate (B regulator, reversible) for port 2, reversible; code: PL, PN The reversible B regulator splits the During venting, the exhaust flow in supply air in duct 1 and regulates the the valve is from duct 2 to duct 1 and pressure upstream of the valve in duct it is reversed into the manifold block 3 (the unregulated pressure from duct via the intermediate plate to duct 3. 1 is in duct 5). The regulated air is then supplied to duct 2. The valve is thus operated in reversible mode. Application examples - When instead of the operating pres � When fast venting is required. sure of the valve terminal, a differ � When the pressure regulator must ent pressure is required in duct 2. always be adjustable. Note -HReversible pressure regulator plates that can be operated in reversible may only be combined with valves mode. ## Advantages - Advantages Restrictions - � Fast cycle times. � Operating pressure is always � 2x 3/2-way valves (code N, K, H) are � 50% higher exhaust flow rate, as air present at the pressure regulator, as not used, as pressure is present at is not exhausted via the pressure the pressure is regulated upstream ports 3 and 5. regulator. The load on the pressure of the valve, i.e. the regulator can regulator is also reduced. always be adjusted. - No quick exhaust valves are required. � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 18 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components ## **Vertical stacking** Mode of operation of the pressure regulator plate (A regulator, reversible) for port 4, reversible; code: PK, PM The reversible A regulator splits the working air in duct 1 and supplies the pressure upstream of the valve into duct 5 (the unregulated pressure from duct 1 is in duct 3). The regulated air is then supplied to duct 4. The valve is thus operated in reversible mode. During venting, the exhaust flow in the valve is from duct 4 to duct 1 and it is reversed into the manifold block via the intermediate plate to duct 5. ## Application examples - When instead of the operating pres � When fast venting is required. sure of the valve terminal, a differ � When the pressure regulator must ent pressure is required in duct 4. always be adjustable. Note -HReversible pressure regulator plates that can be operated in reversible may only be combined with valves mode. ## Advantages - Fast cycle times. � Operating pressure is always - � 50% higher exhaust flow rate, as air present at the pressure regulator, as is not exhausted via the pressure the pressure is regulated upstream regulator. The load on the pressure of the valve, i.e. the regulator can regulator is also reduced. always be adjusted. ## Restrictions - 2x 3/2-way valves (code N, K, H) cannot be used, as pressure is present at ports 3 and 5. - No quick exhaust valves are required. � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 19 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components |**Vertical stacking – P**|**ressure regulator plate**|||||| |---|---|---|---|---|---|---| |Code||Type|Width|Supply pressure||Description| ||||[mm]|6 bar|10 bar|| |Pressure regulatorplate forport 1 (P regulator)||||||| |PA<br>PF||VMPA1-B8-R1-M5-10<br>VMPA1-B8-R1C2-C-10<br>VMPA2-B8-R1C2-C-10|10<br>10<br>20|–|�|Regulates the operating pressure in duct 1<br>upstream of the directional control valve| |||VMPA1-B8-R1-M5-06<br>VMPA1-B8-R1C2-C-06<br>VMPA2-B8-R1C2-C-06|10<br>10<br>20|�|–|| |||||||| |Pressure regulatorplate forport 2 (B regulator)||||||| |PC<br>PH||VMPA1-B8-R2-M5-10<br>VMPA1-B8-R2C2-C-10<br>VMPA2-B8-R2C2-C-10|10<br>10<br>20|–|�|Regulates the operating pressure in duct 2<br>downstream of the directional control valve| |||VMPA1-B8-R2-M5-06<br>VMPA1-B8-R2C2-C-06<br>VMPA2-B8-R2C2-C-06|10<br>10<br>20|�|–|| |||||||| |Pressure regulatorplate forport 4 (A regulator)||||||| |PB<br>PG||VMPA1-B8-R3-M5-10<br>VMPA1-B8-R3C2-C-10<br>VMPA2-B8-R3C2-C-10|10<br>10<br>20|–|�|Regulates the operating pressure in duct 4<br>downstream of the directional control valve| |||VMPA1-B8-R3-M5-06<br>VMPA1-B8-R3C2-C-06<br>VMPA2-B8-R3C2-C-06|10<br>10<br>20|�|–|| |||||||| |Pressure regulatorplate forport 2, reversible (B regulator)||||||| |PL<br>PN||VMPA2-B8-R6C2-C-10|20|–|�|Reversible pressure regulator to port 2| |||VMPA2-B8-R6C2-C-06|20|�|–|| |||||||| |Pressure regulatorplate forport 4, reversible (A regulator)||||||| |PK<br>PM||VMPA2-B8-R7C2-C-10|20|–|�|Reversible pressure regulator to port 4| |||VMPA2-B8-R7C2-C-06|20|�|–|| � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 20 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components ## **Blanking plate** Plate without valve function for Valves and blanking plates are reserving valve positions on a valve attached to the manifold block using terminal. two screws. |**tion**||| |---|---|---| |Circuit symbol|Width|Description| ||[mm]|| |–|10<br>20|For valve terminal only:<br>Blanking plate for vacant valveposition| ## **Compressed air supply and venting** Pneumatic interface The valve terminal MPA-F can be supplied with air at one or more points. The duct and supply cross sections of the MPA-F are extremely effectively sized. Additional supply plates are not generally required. The main supply to the valve ter minal is located on the pneumatic interface, which links the electrical and the pneumatic parts. Additional provision is made for a number of supply plates. Venting is either via flat plate silencers or common ports for ducted exhaust. These vents are located on the pneumatic interface as well as on the supply plates. The exhaust air is always vented via port 82/84 on the right-hand end plate. Supply plate Pneumatic interface with integrated pressure sensor The pneumatic interface is available in a version with integrated pressure sensor for duct 1. The display shows the numerical value for the monitored pressure. The LEDs “psi” and “bar” indicate the pressure value unit. Three further LEDs indicate whether the applied pressure exceeds, conforms to or falls below the setpoint value. You can parameterise the pressure sensor via the PLC or the handheld device (CPX-MMI) from Festo. � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 21 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components ## **Compressed air supply and venting** Work air supply **Power supply module with exhaust plate** Exhaust duct 3 and duct 5 separate Exhaust duct 3/5 common **Pneumatic interface with left-hand end plate** with venting via flat plate silencer, duct 3/5 common The valve terminal MPA-F can be supplied with pressure at one or more points. This is a reliable way of ensuring that all functional compo nents will always offer good performance, even with large-scale extensions. The valve terminal is supplied via the left-hand end plate or power supply modules. Exhaust port 3/5 is either vented via silencers or ports for ducted exhaust air on the power supply modules and on the left-hand end plate. ## Pilot air supply The port for the pilot air supply (port 12/14) is always on the righthand end plate. The ports differ for the following types of pilot air supply: - Internal - External ## **Internal pilot air supply** Internal pilot air supply can be selected if the required working pressure is between 3 and 8 bar. This is done by setting the pilot air supply in the right-hand end plate to this operating mode via a selector switch. The pilot air is branched from port 1 using an internal connection. Port 12/14 must be sealed using a blanking plug. ## **External pilot air supply** If the supply pressure is less than 3 bar or greater than 8 bar, you must operate your MPA-F valve terminal with external pilot air supply. This is done by feeding the pilot air supply via port 12/14 on the righthand end plate. Port 12/14 is equipped with fittings for this pur pose. The selector switch must be set to the appropriate operating mode. Note -H- If a gradual pressure build-up is required in the system by means of a soft-start valve, then external pilot air should be selected whereby the pilot pressure is already applied at the point of switch-on. ## Right-hand end plate with selector switch ## **Internal pilot air supply** ## **External pilot air supply** For end plates with selector switch, the outgoing direction of the ports is to the front of the valve terminal. This means that all of the ports on the terminal can be combined in one outgoing direction. can be set to two different pilot air supply versions. End plates with selector switch set at the factory for: - Internal pilot air supply - External pilot air supply A special feature of the right-hand end plate is the selector switch that � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 22 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components |**Right-hand end plate**|**Right-hand end plate**|**Right-hand end plate**|**Right-hand end plate**|**Right-hand end plate**|| |---|---|---|---|---|---| |Code<br>Type of co|mpressed air supplyandpilot air supply||||Description| |Endplate with select|or switch, internalpilot air supply||||| |S, V, Y|||||Internal pilot air supply<br>�Pilot air supply is branched internally from port 1<br>�Ports 1 and 12/14 are internally connected<br>�Port 12/14 is sealed with a blanking plug<br>�Pilot exhaust air via port 82/84| ||||||| |Endplate with select|or switch, externalpilot air supply||||| |T, X, Z|||||External pilot air supply<br>�Pilot air supply is connected at port 12/14<br>�Pilot exhaust air via port 82/84| ||||||| |**Pneumatic interface**|**with left-hand end plate**||||| |Code<br>Pneumati<br>Graphical|c interface design variants||||Notes| ||symbol|Type|||| |M||VMPAF-FB-EPL<br>VMPAF-FB-EPLM|||�Pneumatic interface for CPX plastic interlinking module<br>�Pneumatic interface for CPX metal interlinking module| |MIPE||VMPAF-FB-EPL-PS<br>VMPAF-FB-EPLM-PS|||�Pneumatic interface for CPX plastic interlinking module, with integrated pres<br>sure sensor for duct 1<br>�Pneumatic interface for CPX metal interlinking module, with integrated pressure<br>sensor for duct 1| |M||VMPAF-MPM-EPL|||�Pneumatic interface for multi-pin plug connection| � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 23 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components |**Pneumatic supply plate (power supply**|**module)**||| |---|---|---|---| |The ducts and supply cross sections of|The pilot exhaust port 82/84 is|Depending on your order, the exhaust|If a separating seal (S, T or R) is| |the MPA-F are extremely effectively|always vented via the right-hand end|ducts are either ducted or vented via|selected directly to the right or left of| |sized. Additional supply plates are not|plate.|the flat plate silencer.|the supply plate, then the code| |generally required.|Supply plates contain the ports:|The supply plate is configured using|letter V or W identifies the position of| |Supply plates can be configured at|�Compressed air supply (1)|the code letter U if no directly adjoin|the left-hand or right-hand separating| |any point upstream or downstream of|�Exhaust air (3/5)|ing separating seal is required.|seal. The code for the separating seal| |manifold blocks for the creation of|||(S, T or R) is placed in front of the code| |pressure zones.|||for the supply plate (V or W).| |**Pneumatic supply plat**|**e (power supply module)**|**e (power supply module)**|| |---|---|---|---| |Code1)<br>Graphical s|ymbol|Type|Notes| |U||VMPAF-SP-P|Supply plate without separating seal<br>(no R, S or T selected)| |V||VMPAF-SP-P|Supply plate with separating seal on left,<br>if R, S or T selected| |W||VMPAF-SP-P|Supply plate with separating seal on right,<br>if R, S or T selected| - 1) The supply plate is equipped with silencer or exhaust plate depending on the code for the air supply S, T, V, X. � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 24 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Electrical components ## **Electrical supply plate** Additional electrical supply plates can **MPA-F with CPX** be used for larger terminals. Electrical supply plates can be This enables up to 64 valve configured at any point upstream positions/128 solenoid coils to or downstream of manifold blocks. be supplied. Note -HPlease note that only electrical modules with isolated electrical circuits are permissible to the right of the electrical supply plate. The electrical supply plate must not be installed directly to the left of a pneumatic supply plate (type VMPA-FB-SP-P). |**Electrical supply plate**|**Electrical supply plate**||| |---|---|---|---| |Code<br>Graphical|symbol|Type|Notes| |L||VMPA-FB-SP-V|Electrical supply plate with M18 plug connection, 3-pin| |||VMPA-FB-SP-7/8-V-5POL|Electrical supply plate with 7/8” plug connection, 5-pin| |||VMPA-FB-SP-7/8-V-4POL|Electrical supply plate with 7/8” plug connection, 4-pin| |**Pin allocation for power supply**|**Pin allocation for power supply**||| |---|---|---|---| |||Pin|Allocation| |Pin allocation for M18|||| |||2|24 V DC valves| |||3|0 VDC| |||4|FE| ||||| |Pin allocation for 7/8”, 5-pin|||| |||1|0 V DC valves| |||2|n.c.| |||3|FE (leading)| |||4|n.c.| |||5|24 V DC valves| ||||| |Pin allocation for 7/8”, 4-pin|||| |||A|n.c.| |||B|24 V DC valves| |||C|FE| |||D|0 V DC valves (leading)| � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 25 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components **Creating pressure zones and separating exhaust air with separating seals** MPA-F offers a number of options for Compressed air is supplied and Separating seals are integrated creating pressure zones if different vented via a supply plate. ex-works as per your order. working pressures are required. The position of the supply plates and Separating seals can be distinguished Depending on the electrical interface, separating seals can be freely se through their coding, even when the up to 16 pressure zones are possible. lected with the valve terminal MPA-F. valve terminal is assembled. Pressure zones are created by isolat ing the internal supply ducts between the manifold blocks using an appropriate separating seal. **Creating pressure zones** Code Separating seal Notes Pictorial examples Coding – No duct separation VMPAF-DP T Duct 1 separated VMPAF-DP-P S Duct 1 and 3/5 separated VMPAF-DP-PRS R Duct 3/5 separated VMPAF-DP-RS � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 26 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components ## **Creating pressure zones with duct separation in the manifold block** A pressure zone is created here by iso Compressed air is supplied and lating the internal supply ducts using vented via a supply plate. a separator that is firmly integrated in the manifold block (code I). Manifold blocks with firmly integrated duct separation can be distinguished by their coding, even when the valve terminal is assembled. ## **Creating pressure zones** |**Creating pressure zones**|**Creating pressure zones**|**Creating pressure zones**|**Creating pressure zones**|**Creating pressure zones**|**Creating pressure zones**|**Creating pressure zones**| |---|---|---|---|---|---|---| |Code|Manifold block with duct separation for operating with flat plate sil||||encer or with ducted exhaust air<br>Note<br>Coding|s| ||Pictorial examples|||||| |I|||||Duct|1 separated| |||||||| |||||||| Note -HThe duct separation cannot be � With width 10 mm between valves subsequently removed and is inte 2 and 3 grated in the centre of the manifold � With width 20 mm between valves block: 1 and 2 ## **Examples: Creating pressure zones** Manifold block with pressure zone separation in duct 1 Another way of creating pressure Zone 1 Zone 2 zones is to use manifold blocks with pressure zone separation. The diagram opposite shows the version with pressure zone separation in duct 1. **==> picture [33 x 50] intentionally omitted <==** � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 27 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components **Examples: Compressed air supply and pilot air supply** Internal pilot air supply, flat plate silencer Air supply to the valve terminal: Optional code S separating seal The diagram opposite shows an example of the configuration and con nection of the air supply with internal pilot air supply. Port 12/14 on the right-hand end plate is sealed with a blanking plug. The selector switch on the right-hand end plate must also be set accordingly. The exhaust port 3/5 is vented via the flat plate silencer. The pilot exhaust port 82/84 is always vented via the right-hand end plate. Separating seals can be used optionally to create pressure zones. External pilot air supply, flat plate silencer Air supply to the valve terminal: Optional code T separating seal The diagram opposite shows an example of the configuration and con nection of the compressed air supply with external pilot air supply. The external pilot air supply is fed to port 12/14 via the right-hand end plate. The selector switch on the right-hand end plate must also be set accord ingly. The exhaust port 3/5 is vented via the flat plate silencer. The pilot exhaust port 82/84 is always vented via the right-hand end plate. Separat ing seals can be used optionally to create pressure zones. **==> picture [37 x 56] intentionally omitted <==** **==> picture [37 x 57] intentionally omitted <==** � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 28 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components **Examples: Compressed air supply and pilot air supply** Internal pilot air supply, ducted exhaust air Air supply to the valve terminal: Optional code V or Y separating seal The diagram opposite shows an example of the configuration and con nection of the compressed air supply with internal pilot air supply. Port 12/14 on the right-hand end plate is sealed with a blanking plug. The selector switch on the right-hand end plate must also be set accordingly. The exhaust port 3/5 is vented via the corresponding ports. The pilot ex haust port 82/84 is always vented via the right-hand end plate. Separating seals can be used optionally to create pressure zones. **==> picture [37 x 57] intentionally omitted <==** External pilot air supply, ducted exhaust air Air supply to the valve terminal: code X or Z The diagram opposite shows an example of the configuration and con nection of the compressed air supply with external pilot air supply. The external pilot air supply is fed to port 12/14 via the right-hand end plate. The selector switch on the right-hand end plate must also be set accord ingly. The exhaust port 3/5 is vented via the corresponding ports. The pilot exhaust port 82/84 is always vented via the right-hand end plate. Separat ing seals can be used optionally to create pressure zones. Optional separating seal **==> picture [37 x 86] intentionally omitted <==** � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 29 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components ## **Manifold block** MPA-F is based on a modular system consisting of manifold blocks and valves. The manifold blocks are screwed together and thus form the support system for the valves. They contain the connection ducts for supplying compressed air to and vent ing from the valve terminal as well as the working lines for the pneumatic actuators for each valve. Each manifold block is connected to the next using two screws. Individual terminal sections can be isolated and further manifold blocks inserted by loosening these screws. This ensures that the valve terminal can be rapidly and reliably extended. ## **Manifold block versions** |Code<br>Graphica|l symbol|Type|Width|Number of valve positions<br>(solenoid coils)|Notes| |---|---|---|---|---|---| ||||[mm]||| |Manifold block for m|ulti-pinplug/fieldbus connection||||| |A, C1)<br>AI, CI1)||VMPAF-AP-4-1|10|4 (8)|Working ports (2, 4)<br>on the manifold block<br>�Connection sizes: MPAF1:<br>M7, QS4, QS6<br>�Code I: Separation in duct 1<br>in the manifold block| |||VMPAF-AP-4-1-T1|||| |B, D1)<br>BI, DI1)||VMPAF-AP-2-2|20|2 (4)|Working ports (2, 4)<br>on the manifold block<br>�Connection sizes MPAF2:<br>G¼, QS8, QS10<br>�Code I: Separation in duct 1<br>in the manifold block| |||VMPAF-AP-2-2-TO|||| 1) Only possible with multi-pin plug connection � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 30 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components ## **Pressure sensor** 1 4 2 3 1 Red LED: Pressure exceeded 2 Green LED: Pressure conforms to 3 Red LED: Pressure fallen below 4 Red LED: Common error display The pressure sensor indicates The pressure in the exhaust ducts whether the applied pressure ex (3/5) and the process pressure ceeds, conforms to or falls below the (external) can also be measured. setpoint value using three LEDs. An Pressure measurement in the additional LED indicates common er exhaust ducts is used for monitoring rors (limit exceeded or fallen below). the operating pressure during The limits for pressure monitoring reversible operation (supply to 3/5). are set by means of parameter set tings. You can parameterise the pressure sensor plate via the PLC or the handheld device (CPX-MMI-1) from Festo. |**Pressure sensor versi**|**ons**||| |---|---|---|---| |Code<br>Graphical|symbol|Type|Use| |PE<br>PF<br>PG||**VMPAF-FB-PS-1**|Monitoring the operating pressure in duct 1| |||**VMPAF-FB-PS-3/5**|Monitoring the pressure in exhaust ducts 3 and 5<br>(pressure monitoring for reversible valve terminal)| |||**VMPAF-FB-PS-P1**|Monitoring an external process pressure| |**Left-hand end plate with**|**Left-hand end plate with**|**integrated pressure**|**integrated pressure**|**integrated pressure**|**integrated pressure**|**sensor**|||| |---|---|---|---|---|---|---|---|---|---| |1||||||5|1|Red LED: Upper limit exceeded|The left-hand end plate with| |2|||||||2|Green LED: Pressure in nominal|pneumatic interface can be equipped| |3||||||6|3|range<br> Display|with an integrated pressure sensor.<br>The pressure sensor measures the| |4||||||7|4 <br>5|Red LED: Limit not reached<br> Red LED: Common error display|operating pressure in duct 1. The<br>measured value is displayed numeri| The left-hand end plate with pneumatic interface can be equipped with an integrated pressure sensor. The pressure sensor measures the operating pressure in duct 1. The measured value is displayed numeri cally and sent to the master controller via the CPX bus node by means of serial linking. - 5 Red LED: Common error display - 6 Yellow LED: Value in display shown in bar - 7 Yellow LED: Value in display shown in psi **==> picture [42 x 83] intentionally omitted <==** - This ensures that the system part in question is always operated above a required minimum pressure, but not in the range of excess pressures, which can impair operation. � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 31 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components |**Electrical interface versions**|**Electrical interface versions**||||| |---|---|---|---|---|---| |Code<br>Gra|phical symbol|Type|Width|Number of valve posi<br>tions (solenoid coils)|Notes| ||||[mm}||| |Electronics mo|dule for multi-pinplug||||| |A, B, C, D||VMPA1-MPM-EMM-8<br>VMPA1-MPM-EMM-4|10|4 (8)<br>4 (4)|Each solenoid coil must be assigned to<br>a specific pin of the multi-pin plug in<br>order for the valve to be actuated. Re<br>gardless of the blanking plates or<br>valves used, valve positions occupy<br>�1 address for actuation of 1 coil<br>�2 addresses for actuation of 2 coils| |||VMPA2-MPM-EMM-4<br>VMPA2-MPM-EMM-2|20|2 (4)<br>2 (2)|| ||||||| |Electronics mo|dule for fieldbus with standard diagnostics||||| |A, B, AH,<br>BH||VMPA…-FB-EMS-…<br>VMPA…-FB-EMG-…|10|4 (8)|The electronics module contains the<br>serial communication system and<br>facilitates:<br>�Transmission of switching<br>information<br>�Actuation of up to 8 solenoid coils<br>�Position-based diagnostics<br>�Separate voltage supply for valves<br>�Transmission of status, parameter<br>and diagnostic data<br>There are different versions:<br>�Without isolated electrical circuit<br>(VMPA…-FB-EMS-…)<br>�With isolated electrical circuit<br>(VMPA…-FB-EMG-…)<br>Diagnostic function:<br>�Error: Load voltage of the valves| |||VMPA…-FB-EMS-…<br>VMPA…-FB-EMG-…|20|2 (4)|| ||||||| |Electronics mo|dule for fieldbus with extended diagnostic function||||| |A, B, AH,<br>BH<br>with: D2||VMPA…-FB-EMS-…-D2<br>VMPA…-FB-EMG-…-D2|10|4 (8)|The electronics module with extended<br>diagnostic function contains the same<br>functions as the electronics module<br>with standard diagnostics.<br>The diagnostic function, however,<br>has been extended:<br>�Error: Load voltage of the valves<br>�Error: Wire break (open load)<br>�Error: Short circuit in load voltage of<br>valves<br>�Message: Condition monitoring| |||VMPA…-FB-EMS-…-D2<br>VMPA…-FB-EMG-…-D2|20|2 (4)|| ||||||| |-H-<br>Note<br>�Multi-pin plug with modular<br>linking<br>�Manifold blocks MPAF1<br>and MPAF2 can be combined<br>as required<br>�Positive or negative switching<br>actuation is possible<br>(mixed operation is not permitted)<br>�Double solenoid valves cannot be<br>mounted on single solenoid<br>electronics modules<br>|||||�Single solenoid valves can be<br>mounted on double solenoid<br>electronics modules| � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 32 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Pneumatic components |**Ports for supply and ex**|**haust**|||||| |---|---|---|---|---|---|---| |Code||Connection|Designation|Plug connector,<br>large|Plug connector,<br>small|**Code D**<br>Thread for<br>supply| |S||Internal pilot air supply, silencer||||| |||1<br>Supply air/<br>vacuum supply|Push-in fitting|QS-G½-16<br>–|QS-G½-12<br>QS-1/2-1/2-I-U-M|G½| |||3/5<br>Exhaust air|Flat plate silencer|–|–|–| |||12/14<br>Pilot air supply|–|–|–|–| |||82/84<br>Pilot exhaust air|Push-in fitting|QS-G¼-10-I<br>QS-1/4-3/8-I-U-M|QS-G¼-8-I<br>QS-1/4-5/16-I-U-M|G¼| ||||Silencer|–|–|G¼| |||||||| |T||External pilot air supply, silencer||||| |||1<br>Supply air/<br>vacuum supply|Push-in fitting|QS-G½-16<br>–|QS-G½-12<br>QS-1/2-1/2-I-U-M|G½| |||3/5<br>Exhaust air|Flat plate silencer|–|–|–| |||12/14<br>Pilot air supply|Push-in fitting|QS-G¼-10-I<br>QS-1/4-3/8-I-U-M|QS-G¼-8-I<br>QS-1/4-5/16-I-U-M|G¼| |||82/84<br>Pilot exhaust air|Push-in fitting|QS-G¼-10-I<br>QS-1/4-3/8-I-U-M|QS-G¼-8-I<br>QS-1/4-5/16-I-U-M|G¼| ||||Silencer|–|–|G¼| |||||||| |V, Y<br>X, Z||Internal pilot air supply, ducted exhaust air||||| |||1<br>Supply air/<br>vacuum supply|Push-in fitting|QS-G½-16<br>–|QS-G½-12<br>QS-1/2-1/2-I-U-M|G½| |||3/5<br>Exhaust air|Push-in fitting|QS-G½-16<br>–|QS-G½-12<br>QS-1/2-1/2-I-U-M|G½| |||12/14<br>Pilot air supply|–|–|–|–| |||82/84<br>Pilot exhaust air|Push-in fitting|QS-G¼-10-I<br>QS-1/4-3/8-I-U-M|QS-G¼-8-I<br>QS-1/4-5/16-I-U-M|G¼| |||||||| |||External pilot air supply, ducted exhaust air||||| |||1<br>Supply air/<br>vacuum supply|Push-in fitting|QS-G½-16<br>–|QS-G½-12<br>QS-1/2-1/2-I-U-M|G½| |||3/5<br>Exhaust air|Push-in fitting|QS-G½-16<br>–|QS-G½-12<br>QS-1/2-1/2-I-U-M|G½| |||12/14<br>Pilot air supply|Push-in fitting|QS-G¼-10-I<br>QS-1/4-3/8-I-U-M|QS-G¼-8-I<br>QS-1/4-5/16-I-U-M|G¼| |||82/84<br>Pilot exhaust air|Push-in fitting|QS-G¼-10-I<br>QS-1/4-3/8-I-U-M|QS-G¼-8-I<br>QS-1/4-5/16-I-U-M|G¼| ||||Silencer|–|–|G¼| � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 33 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Assembly ## **Valve terminal assembly** Sturdy terminal mounting thanks to: � Four through-holes for wall � Additional mounting brackets mounting � H-rail mounting Wall mounting – Multi-pin plug connection **==> picture [121 x 69] intentionally omitted <==** Wall mounting – Fieldbus connection H-rail mounting **A B** Note -HWhen wall-mounting MPA-F valve prevent damage to the valve terminals with more than 4 manifold terminal. The mounting brackets can blocks, use additional mounting be mounted on the pneumatic supply brackets of the type VMPA-BG-RW to plates. The MPA-F valve terminal is screwed Optional mounting brackets are also onto the mounting surface using four available. M6 screws. The mounting holes are on the pneumatic interface and on the right-hand end plate. The MPA-F valve terminal is screwed The pneumatic interface also provides onto the mounting surface using six further mounting holes as well as M6 screws. The mounting holes are on optional mounting brackets. the left-hand end plate (CPX) and on the right-hand end plate (MPA-F). For H-rail mounting of the valve terminal you will need the following MPA-F mounting kit: The MPA-F valve terminal is attached to the H-rail (see arrow A). The valve terminal MPA-F is then swivelled onto the H-rail and secured in place with the clamping compo nents (see arrow B). - With multi-pin plug: CPA-BG-NRH - With fieldbus: VMPAF-FB-BG-NRH - This enables mounting of the valve terminal on a H-rail to EN 60715. � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 34 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Display and operation ## **Display and operation** Each solenoid coil is allocated an LED that indicates its signal status. ## **Manual override** that indicates its signal status. The manual override (MO) enables � Indicator 12 shows the signal the valve to be actuated when not status of the coil for output 2 electrically activated or energised. � Indicator 14 shows the signal The valve is switched by pushing the status of the coil for output 4 manual override. The set switching status can also be locked by turning the manual override (code R or as accessory). Alternatives: - A cover (code N or as accessory) can be fitted over the manual override to prevent it from being locked. The manual override can then only be activated by pushing it. - A cover (code V) can be fitted over the manual override to prevent it from being accidentally activated. ## Pneumatic connection and control elements **==> picture [178 x 421] intentionally omitted <==** **----- Start of picture text -----**<br> 1 2 3<br>6 5<br>Electrical connection and display components for fieldbus<br>5 6<br>4<br>3<br>2<br>1<br>**----- End of picture text -----**<br> **==> picture [64 x 99] intentionally omitted <==** **----- Start of picture text -----**<br> 6 5 4<br>**----- End of picture text -----**<br> Electrical connection and display components for fieldbus - 1 Flat plate silencer for exhaust port 3/5 - 2 Manual override (for each pilot solenoid coil, non-detenting or non-detenting/detenting) - 3 Adjusting knob for optional pressure regulator plate - 4 Working ports 2 and 4, for each valve position - 5 Supply port 1 - 6 Pressure gauge (optional) - 1 Power supply connection - 2 Earthing screw - 3 Fieldbus connection - (bus-specific) - 4 Service interface for handheld unit, etc. - 5 Pneumatic interface with optional integrated pressure sensor - 6 Diagnostic LEDs for valves Note -HA manually actuated valve (manual override) cannot be reset electri cally. Conversely, an electrically actuated valve cannot be reset using the mechanical manual override. � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 35 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Display and operation ## **Manual override (MO)** MO with automatic return (non-detenting) MO set via turning (detenting) **==> picture [316 x 123] intentionally omitted <==** **----- Start of picture text -----**<br> 1 Press in the stem of the MO with<br>1 2 1 2<br>a pin or screwdriver.<br>Pilot valve switches and actuates<br>the main valve.<br>2 Remove the pin or screwdriver.<br>Spring force pushes the stem of<br>the MO back.<br>Pilot valve returns to the initial<br>position and so too the single<br>solenoid main valve (not with<br>double solenoid valve code J).<br>**----- End of picture text -----**<br> - 1 Press in the stem of the MO with a pin or screwdriver until the valve switches and then turn the stem clockwise by 90° until the stop is reached. Valve remains switched. - 2 Turn the stem anti-clockwise by 90° until the stop is reached and then remove the pin or screwdriver. Spring force pushes the stem of the MO back. Valve returns to initial position (not with double solenoid valve code J). ## **Identification system** **==> picture [210 x 294] intentionally omitted <==** **----- Start of picture text -----**<br> Inscription panel<br>approx. 20 x 45 mm<br>Inscription label<br>holder<br>VMPAF-ST1<br>VMPAF-ST1T<br>Retainer<br>VMPAF-STH<br>Inscription panel<br>approx. 20 x 45 mm<br>Retainer<br>VMPAF-STH<br>Inscription label<br>holder<br>VMPAF-ST1<br>VMPAF-ST1T<br>**----- End of picture text -----**<br> An inscription label holder VMPAF-ST1 (Part No. 546 228, code T in the order code, for holding paper labels) or VMPAF-ST1T (Part No. 544 422, for holding IBS-9x20 inscription labels) can be mounted on each manifold rail for labelling the valves. Large inscription labels (20 x 45 mm) can be attached to the pneumatic in terface as an alternative or in addition to the smaller labels. Inscription label holders can be ap plied on different sides using circular clips in order to identify pneumatic threaded connectors, solenoid coils or manual override tools, for example. � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 36 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Electrical components ## **Electrical power as a result of current reduction** Power management **Individual valve** Valves can also be used on individual � Detachable electronics module with sub-bases for actuators further away integrated holding current from the valve terminal. reduction Each MPA solenoid coil is protected with a spark arresting protective circuit as well as against polarity reversal. All valve types are additionally equipped with integrated current reduction. - Electrical M8 connection, 4-pin with screw connection MPA valves are supplied with operat ing voltage in the range 18 … 30 V (24 V +/–25%). This high tolerance is made possible through integrated control electronics and offers addi tional security, e.g. if the operating voltage drops. Note -H- Further information can be found on: � VMPA1 ## **Electrical multi-pin plug connection** this means that 24 valves, each with a single solenoid coil, can be addressed. The following multi-pin plug connec pins up to 24 are left free. Pin 25 is this means that 24 valves, each with tion is offered for the valve terminal reserved for the neutral conductor. a single solenoid coil, can be MPA-F: The valves are switched by means of addressed. � Sub-D multi-pin plug connection positive or negative logic (PNP or With 12 or fewer valve positions, (25-pin) NPN). Mixed operation is not 2 solenoid coils per valve can be ad permitted. dressed. With 12 or more valve posi Pins 1 … 24 are used for addresses Each pin on the multi-pin plug can tions, the number of available valve 1 … 24 in order. actuate exactly one valve solenoid positions for valves with two solenoid If fewer than 24 addresses are used coil. If the maximum configurable coils decreases. for the valve terminal, the remaining number of valve positions is 24, Note -H- If a single solenoid valve is as sembled on a double solenoid valve position, the second address is also occupied and cannot be used. - **CPX fieldbus connection** - All functions and features of the elec � The valves and electrical outputs � The valves are supplied and trical peripherals CPX are permitted in are supplied via the operating disconnected separately -HNote connection with the CPX interface. voltage connection CPX via a separate valve connection Further information can be found This means: on the CPX (code V) on: � Internet: cpx - Guidelines on addressing for valves/solenoid coils - � The maximum possible number of – Manifold rail MPAF1 for 4 double � The numbering of the addresses � If single solenoid valves are addresses with a multi-pin plug solenoid valves: 8 goes from left to right in ascending mounted on manifold blocks for connection is 24 – Manifold rail MPAF2 for 2 single consecutive order. The following double solenoid valves, the address - � Each manifold block/electronics solenoid valves: 2 applies to the individual valve of coil 12 and the assigned pin will module occupies a defined number – Manifold rail MPAF2 for 2 double positions: address x for coil 14 and remain unused of addresses/pins: solenoid valves: 4 address x+1 for coil 12 – Manifold rail MPAF1 for 4 single solenoid valves: 4 � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 37 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Electrical components **Pin allocation – Sub-D socket, cable** |**Pin allocation – Sub-D socket, cable**|**Pin allocation – Sub-D socket, cable**|**Pin allocation – Sub-D socket, cable**|**Pin allocation – Sub-D socket, cable**|**Pin allocation – Sub-D socket, cable**|**Pin allocation – Sub-D socket, cable**|**Pin allocation – Sub-D socket, cable**|**Pin allocation – Sub-D socket, cable**| |---|---|---|---|---|---|---|---| ||Pin|Address/coil|Wire colour2)||Pin|Address/coil|Wire colour2)| ||1<br>2<br>3<br>4<br>5<br>6<br>7<br>8<br>9<br>10<br>11<br>12<br>13<br>14<br>15<br>16|0<br>1<br>2<br>3<br>4<br>5<br>6<br>7|WH<br>GN<br>YE<br>GY<br>PK<br>BU<br>RD<br>VT||17<br>18<br>19<br>20<br>21<br>22<br>23<br>24|16<br>17<br>18<br>19<br>20<br>21<br>22<br>23|WH PK<br>PK BN<br>WH BU<br>BN BU<br>WH RD<br>BN RD<br>WH BK<br>BN| |||8<br>9<br>10<br>11<br>12<br>13<br>14<br>15|GY PK<br>RD BU<br>WH GN<br>BN GN<br>WH YE<br>YE BN<br>WH GY<br>GY BN||25|0 V1)|BK| ||||||||| ||||||-H-<br>Note<br>The drawing shows a view on the Sub-D socket on<br>the multi-pin cable VMPA-KMS1-….||| - 1) 0 V for positive switching control signals; connect 24 V for negative switching control signals; mixed operation is not permitted. - 2) To IEC 757 |**Dimensions**|**Dimensions**||||Download CAD data �**www.festo.com**|Download CAD data �**www.festo.com**|Download CAD data �**www.festo.com**|Download CAD data �**www.festo.com**|Download CAD data �**www.festo.com**|Download CAD data �**www.festo.com**|Download CAD data �**www.festo.com**|Download CAD data �**www.festo.com**| |---|---|---|---|---|---|---|---|---|---|---|---|---| |Connecting cab||les||||||||||| ||||||1 Cable connector with clamping<br>range 6 … 12 mm<br>The wire colours refer to the following<br>pre-assembled multi-pin cables from<br>Festo:<br>�VMPA-KMS1-8-… Valve terminal for<br>up to 4 valve positions (8 coils)<br>�VMPA-KMS1-24-… Valve terminal|||||||| |||||||||||||| ||||||with 8 … 24 valve positions|||||||| |||||||||||||| |||||||||||||| |||||||||||||| |||||||||||||| |Type||||L1||||L2|B1|H1|H2|H3| |VMPA-KMS-H||||107.3||||26|37.6|28|20|13.8| |Type|Sheath|Length|Wire x mm2|D|Part No.| |---|---|---|---|---|---| |||[m]||[mm]|| |VMPA-KMS1-8-2.5|PVC|2.5|10 x 0.34|6.9|**533195**| |VMPA-KMS2-8-2.5-PUR|PUR|2.5|10 x 0.25|8.3|**533504**| |VMPA-KMS1-8-5|PVC|5|10 x 0.34|6.9|**533196**| |VMPA-KMS2-8-5-PUR|PUR|5|10 x 0.25|8.3|**533505**| |VMPA-KMS1-8-10|PVC|10|10 x 0.34|6.9|**533197**| |VMPA-KMS2-8-10-PUR|PUR|10|10 x 0.25|8.3|**533506**| |VMPA-KMS1-24-2.5|PVC|2.5|25 x 0.34|11.4|**533192**| |VMPA-KMS2-24-2.5-PUR|PUR|2.5|25 x 0.25|11.2|**533501**| |VMPA-KMS1-24-5|PVC|5|25 x 0.34|11.4|**533193**| |VMPA-KMS2-24-5-PUR|PUR|5|25 x 0.25|11.2|**533502**| |VMPA-KMS1-24-10|PVC|10|25 x 0.34|11.4|**533194**| |VMPA-KMS2-24-10-PUR|PUR|10|25 x 0.25|11.2|**533503**| |VMPA-KMS-H|Cover for self-assembly||||**533198**| � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 38 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Key features – Electrical components ## **Instructions for use** ## System equipment Operate system equipment with unlu bricated compressed air if possible. Festo valves and cylinders are de signed so that, if used as designated, they will not require additional lu brication and will still achieve a long service life. The quality of compressed air down stream from the compressor must correspond to that of unlubricated compressed air. If possible, do not operate all of your system equipment with lubricated compressed air. The lubricators should, where possible, always be installed directly upstream of the actuator used. Unsuitable additional oil and an ex cessive oil content in the compressed air reduce the service life of the valve terminal. Use Festo special oil OFSW-33 or the alternatives listed in the Festo catalogue (as specified in DIN 51524 HLP32; basic oil viscosity 32 CST at 40 °C). ## Bio-oils When using bio-oils (oils which are based on synthetic or native ester, e.g. rapeseed oil methyl ester), the maximum residual oil content of 0.1 mg/m[3] must not be exceeded (see ISO 8573-1 Class 2). ## Mineral oils When using mineral oils (e.g. HLP oils to DIN 51524, parts 1 through 3) or similar oils based on poly-alphaolefins (PAO), the maximum residual oil content of 5 mg/m[3] must not be exceeded (see ISO 8573-1 Class 4). A higher residual oil content irrespec tive of the compressor oil cannot be permitted, as the basic lubricant would be flushed out over time. � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 39 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Technical data -MFlow rate MPAF1: Up to 360 l/min MPAF2: Up to 900 l/min -KValve width MPAF1: 10 mm MPAF2: 20 mm -PVoltage 24 V DC |**General technical data**<br>Type<br>MPAF-MPM-VI<br>MPAF-FB-VI|**General technical data**<br>Type<br>MPAF-MPM-VI<br>MPAF-FB-VI|**General technical data**<br>Type<br>MPAF-MPM-VI<br>MPAF-FB-VI| |---|---|---| |Valve terminal design|Modular, valve sizes can be mixed|| |Electrical actuation|Multi-pinplug|Fieldbus| |Actuation type|Electric|| |Nominal voltage<br>[V DC]|24|| |Operatingvoltage range<br>[V DC]|18 … 30|| |Max. no of valvepositions|24|64| |Max. no. ofpressure zones|7|17| |Valve size<br>[mm]|10, 20|| |Pilot air supply|Internal or external|| |Lubrication|Life-time lubrication, PWIS-free (free ofpaint-wettingimpairment substances)|| |Type of mounting|Wall mounting|| ||On H-rail to EN 60715|| |Mounting position|Any|| ||Horizontal only (H-rail)|| |Manual override|Non-detenting, detenting, blocked|| |Protection class to EN 60529|IP65 (for all types of signal transmission in assembled state)|| |||| |Pneumatic connections||| |Pneumatic connection|Via manifold block|| |Supply port<br>1|QS-G½-12, QS-G½-16, QS-1/2-1/2-I-U-M|| |Exhaustport<br>3/5|Via flatplate silencer or exhaustplate|| |Working ports<br>2/4|Dependent on the connection type selected<br>MPAF1: QSM-M7-6-I, QSM-M7-4-I, QSM-M7-3/16-I-U-M, QSM-M7-1/4-I-U-M<br>MPAF2: QS-G¼-8-I, QSG¼-10-I, QS-1/4-5/16-I-U-M, QS-1/4-3/8-I-U-M|| |Pilot airport<br>12/14|QS-G¼-8-I, QS-G¼-10-I, QS-1/4-5/16-I-U-M, QS-1/4-3/8-I-U-M|| |Pilot exhaust airport<br>82/84|QS-G¼-8-I, QS-G¼-10-I, QS-1/4-5/16-I-U-MI, QS-1/4-3/8-I-U-M|| |Pressure compensation port|With ducted exhaust air: via port 82/84<br>With flat plate silencer: venting to atmosphere|| Note -HNote possible restrictions for the IP protection class > ATEX conformity declaration **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 40 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Technical data |**Operating and environmental conditions**|**Operating and environmental conditions**||| |---|---|---|---| |Operatingmedium||Compressed air accordingto ISO 8573-1:2010 [7:4:4]|| |Note on operating/pilot medium||Lubricated operationpossible (in which case lubricated operation will always be required)|| |Operating pressure<br>[bar]||–0.9 … +10|| |Pilotpressure<br>[bar]||3 … 8|| |Ambient temperature<br>[°C]||–5 … +50|| |Temperature of medium<br>[°C]||–5 … +50|| |Storage temperature1)<br>[°C]||–20 … +40|| |Relative air humidityat 40 °C<br>[%]||90|| |1)<br>Long-term storage|||| |**Certifications1)**|||| |Type|**MPAF-MPM-VI**<br>**(multi-pin plug interface)**||**MPAF-FB-VI**<br>**(fieldbus interface)**| |Part number|**544398**||**544397**| |ATEX categoryforgas|II 3 G||| |Explosion ignition protection type<br>for gas|Ex nA IIC T4 X Gc||| |ATEX temperature rating<br>[°C]|–5 ≤ Ta ≤ +50||| |CE marking<br>(see declaration of conformity)|To EU EMC Directive2)||| ||To EU Explosion Protection Directive (ATEX)||–| - 1) Interface versions that are not listed do not have any of the listed certifications - 2) For information about the applicability of the component see the manufacturer’s EC declaration of conformity at: www.festo.com/sp � Certificates. If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary. � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 41 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Technical data **Pilot pressure p2 as a function of working pressure p1 with external pilot air supply** For valves with code: M, J, B, G, E, W, X For valves with code: N, K, H, D, I - 1 Operating range for valves with external pilot air supply - 1 Operating range for valves with external pilot air supply **Pilot pressure p2 as a function of working pressure p1 for valves with mechanical spring return** For valves in width 10 mm with code: MS, NS, KS, HS, DS For valves in width 20 mm with code: MS, NS, KS, HS, DS For valves in width 10 mm with code: MU, NU, KU, HU **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 42 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Technical data **Flow rate qn as a function of output pressure p2 with pressure regulator plates (width 20 mm) (P regulator plate) for port 1** **==> picture [89 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> (B regulator plates) for port 2<br>**----- End of picture text -----**<br> Supply pressure 10 bar, set regulator pressure 6 bar **==> picture [83 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Supply pressure 10 bar,<br>set regulator pressure 6 bar<br>**----- End of picture text -----**<br> **Flow rate qn as a function of output pressure p2 with pressure regulator plates (width 20 mm) (A regulator plates) for ports 4** **==> picture [212 x 169] intentionally omitted <==** **----- Start of picture text -----**<br> (B regulator plates, rev.) for ports 3, reversible<br>Supply pressure 10 bar,<br>set regulator pressure 6 bar<br>**----- End of picture text -----**<br> Supply pressure 10 bar, set regulator pressure 6 bar **Flow rate qn as a function of output pressure p2 with pressure regulator plates (width 20 mm) (A regulator plates, rev.) for ports 5, reversible** Supply pressure 10 bar, set regulator pressure 6 bar � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 43 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Technical data |**Technical data – Valves in width 10 mm**|**Technical data – Valves in width 10 mm**||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---| |Code||M|J|N|K|H|B|G|E|X|W|D|I| |Switching times|On<br>[ms]|10|10|10|10|10|10|10|10|10|10|10|10| ||Off<br>[ms]|20|–|20|20|20|35|35|35|20|20|20|20| ||Change<br>over<br>[ms]|–|15|–|–|–|15|–|15|–|–|–|–| |Operating pressure|[bar]|–0.9 … +10||3 … 10|||–0.9 … +10|||||3 … 10|| |Standard nominal flow rate<br>[l/min]||360|360|300|230|300|300|320|240|255|255|230|260| |Design||Piston spool valve|||||||||||| |Max. tightening torque of valve<br>mounting<br>[Nm]||0.25|||||||||||| |Materials||Die-cast aluminium|||||||||||| |Product weight<br>[g]||49|56|56|56|56|56|56|56|49|49|56|56| |**Technical data – Valves in width 10 mm**|**Technical data – Valves in width 10 mm**|||||||||| |---|---|---|---|---|---|---|---|---|---|---| |Code||MS|NS|KS<br>|HS|DS|MU|NU|KU|HU| |Switching times|On<br>[ms]|10|14|14<br>|14|14|10|8|8|8| ||Off<br>[ms]|27|16|16<br>|16|16|12|8|10|10| ||Change<br>over<br>[ms]|–|–|–<br>|–|–|–|–|–|–| |Operating pressure|[bar]|–0.9 … +8|||||–0.9 … +10|||| |Standard nominal flow rate<br>[l/min]||360|300|230<br>|300|230|190|190|160|190| |Design||Piston spool valve|||||Poppet valve with spring return|||| |Max. tightening torque of valve<br>mounting<br>[Nm]||0.25||||||||| |Materials||Die-cast aluminium|||||Reinforced PPA|||| |Product weight<br>[g]||56|56|56<br>|56|56|35|42|42|42| |**Technical data – Valves in width 20 mm**|**Technical data – Valves in width 20 mm**|||||||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |Code||M|J|N|K|H|B|G|E|X|W|D|I|MS|NS|KS|HS|DS| |Switching times|On<br>[ms]|15|9|8|8|8|11|10|11|13|13|7|7|8|12|12|12|12| ||Off<br>[ms]|28|–|28|28|28|46|40|47|22|22|25|25|36|25|25|25|25| ||Change<br>over<br>[ms]|–|22|–|–|–|23|21|23|–|–|–|–|–|–|–|–|–| |Operating pressure|[bar]|–0.9 … +10||3 … 10|||–0.9 … +10|||||3 … 10||–0.9 … +8||||| |Standard nominal flow rate<br>[l/min]||670|670|550|500|550|510|610|590|470|470|650|650|670|550|500|550|650| |Design||Piston spool||valve||||||||||||||| |Max. tightening torque of valve<br>mounting<br>[Nm]||0.65||||||||||||||||| |Materials||Die-cast aluminium||||||||||||||||| |Product weight<br>[g]||100||||||||||||||||| � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 44 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Technical data ## **Electrical data** |**Electrical data**|**Electrical data**|**Electrical data**| |---|---|---| |MPA-F with electronics module VMPA…-FB… (CPX terminal, CPI interface)||| |Voltage supplyfor electronics (VEL/SEN)||| |Nominal voltage<br>[V DC]|24|| |Operatingvoltage range<br>[V DC]|18 … 30|| |Max. intrinsic current consumption per electronics<br>module at 24 V (regardless of the switching status of<br>the valves)<br>[mA]|20|| |||| |Load voltage supplyof valves (VvAL)||| |Nominal voltage<br>[V DC]|24|| |Operating voltage range<br>[V DC]|18 … 30|| |||| |Max. intrinsic current consumptionper electronics module at 24 V (regardless of the switchingstatus of the valves)||| |VMPA1-FB-EMS-8 or VMPA2-FB-EMS-4<br>Without separate circuit<br>(max. signal line length 10 m)<br>[mA]|8|| |VMPA1-FB-EMG-8 or VMPA2-FB-EMG-4<br>With separate circuit<br>[mA]|25|| |||| |Diagnostic message on undervoltage VvALLoad voltage<br>outside function range<br>[V]|17.5 … 15.5|| |||| |Protection class to EN 60529|IP65 (for all types of signal transmission in assembled state)|| |||| |Maximum current consumption per solenoid coil at<br>nominal voltage|MPA1|MPA2| |Nominalpick-upcurrent<br>[mA]|58|99| |Nominal current with current reduction<br>[mA]|9|18| |Time until current reduction<br>[ms]|24|24| |||| |Calculation example||| |Current consumption with two solenoid coils MPAF2<br>switched in parallel and one electronics module<br>without separate circuit<br>[mA]|IEl/SEN= 20|| |Nominalpick-upcurrent<br>[mA]|IVAL =8 + 2 x 90 = 188|| |Nominal current with current reduction<br>[mA]|IVAL =8 + 2 x 18 = 44|| ## **Electrical data** |**Electrical data**|**Electrical data**|**Electrical data**| |---|---|---| |MPAF with electronics module VMPA…-MPM (multi-pinplug)||| |Voltage supply||| |Nominal voltage<br>[V DC]|24|| |Operatingvoltage range<br>[V DC]|18 … 30|| |Residual ripple<br>[Vss]|4|| |||| |Current consumption at Sub-D multi-pin plug connection per<br>solenoid coil at nominal voltage|MPA1|MPA2| |Nominalpick-upcurrent<br>[mA]|80|100| |Nominal current with current reduction<br>[mA]|25|20| |Time until current reduction<br>[ms]|25|50| � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 45 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Technical data |**Data on vibration and shock1)3) to DIN/EC68**|**Data on vibration and shock1)3) to DIN/EC68**| |---|---| |Vibration|Tested according to DIN/IEC68 / EN60068 parts 2 … 6<br>With horizontal H-rail mounting: severity level 1<br>With wall mounting2)| |Shock|Tested according to DIN/IEC68 / EN60068 parts 2 … 27<br>With horizontal H-rail mounting: severity level 1<br>With wall mounting2)| |Continuous shock|Tested according to DIN/IEC68 / EN 60068 parts 2 … 29<br>With wall and H-rail mounting: severity level 1| - 1) See the CPX System manual for information on vibration and shock for the CPX terminal. - 2) Valve terminal MPA-F with CPX terminal or multi-pin plug connection and a pneumatic part not longer than 300 mm without additional fastenings: severity level 2 - A pneumatic part longer than 300 mm with additional fastenings (wall brackets) every 250 mm: severity level 2 - 3) See table below for explanations of the severity levels. |**Test conditions**|||| |---|---|---|---| |Severitylevel|Vibration|Shock|Continuous shock| |1|0.15 mm travel at 10 … 58 Hz,<br>2 g acceleration at 58 … 150 Hz|±15 g at 11 ms duration,<br>5 shocks per direction|±15 g at 6 ms duration,<br>1,000 shocks per direction| |2|0.35 mm travel at 10 … 60 Hz,<br>5 g acceleration at 60 … 150 Hz|±30 g at 11 ms duration,<br>5 shocks per direction|–| |Continuous shock resistance|To DIN/IEC 68/EN 60068,parts 2-29: +/–15gat 6 ms, 1,000 cycles||| � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 46 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Technical data |**Materials**|| |---|---| |Manifold block|Die-cast aluminium| |Seals|NBR, elastomer| |Supply plate|Die-cast aluminium| |Right-hand endplate|Die-cast aluminium| |Left-hand pneumatic interface|Die-cast aluminium, PA| |Exhaustplate|Die-cast aluminium, wrought aluminium alloy| |Flatplate silencer|PE| |Electrical supply plate|Housing: Die-cast aluminium<br>End cap: Reinforced PA| |Electronics module|PA| |Electrical interlinkingmodule|Bronze/PBT| |Regulatorplate|Control section, housing: PA; Seals: NBR| |Note on materials|RoHS-compliant| |**Product weight**||| |---|---|---| |Approx. weight [g]|MPA1|MPA2| |Sub-base1)|375|345| |Per vacantposition L|24|44| |Right-hand end plate1)|270|| |Endplate VMPAL-EPL-IPO32|170|| |CPX module (complete)|210|| |CPX left-hand endplate|80|| |Left-hand pneumatic interface1)multiple connector<br>plate with exhaust plate/flat plate silencer|730|| |Pneumatic supply plate1)with exhaust plate/flat plate<br>silencer|430|| |Electrical supply plate1)|370|| |Pressure sensor|370|| |Regulatorplate|70|180| |QSM-M7-¼-I-U-M<br>QSM-M7-4-I, QSM-M7-Ã-I-U-M<br>QSM-M7-6-I<br>QS-¼-Ä-I-U-M<br>QS-¼-Å-I-U-M<br>QS-G¼-8-I<br>QS-G¼-10-I<br>QS-½-½-I-U-M<br>QS-G½-12<br>QS-G½-16|4<br>6<br>6<br>14<br>21<br>22<br>22<br>45<br>46<br>53|| 1) Via accessories � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 47 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Technical data |**mensions**||||||Download CAD data �**www.festo.com**|Download CAD data �**www.festo.com**|Download CAD data �**www.festo.com**|Download CAD data �**www.festo.com**|Download CAD data �**www.festo.com**| |---|---|---|---|---|---|---|---|---|---|---| |ve terminal with|multi-pin plug connection|||||||||| |||||||||||| |||||||||||| |||||||||||| |||||||||||| |||||||||||| |||||||||||| |||||||||||| |||||||||||| |||||||||||| |Solenoid valve<br> Solenoid valve<br> Manual overri|MPA1<br>MPA2<br>de<br>4 Pilot<br>air<br>5 Work<br>6 H-rai|air supply, pilot exhaust<br>ing ports<br>l<br>7 H-rail mounting<br>8 Mounting holes<br>9 Multi-pin plug connection||||||||| |||||||||||| |e<br>B1|B2<br>B3|B4<br>B6<br>B8|B9||B10|B11|B13||B14|| |A-F (MP)<br>17|5.1<br>133.3<br>134.7|107.3<br>65<br>26|27.4||23.5|17|7.5||6.6|| |||||||||||| |e<br>L1|L21)<br>L3<br>L|4<br>L5<br>L6<br>L7|L8|L9<br>L||10<br>L11||L12||L13| |A-F (MP)<br>86|.6<br>n x 47.6<br>38.5<br>3|4.6<br>22.3<br>31<br>21|20.4|8.4<br>||7.5<br>6.6||4||1.5| |||||||||||| |e<br>H1|H2<br>H3|H4<br>H5<br>H6<br>|H7|H8<br>H9||H10||H11||H12| |A-F (MP)<br>15|2<br>109<br>67.5|53.8<br>29.6<br>33.1<br>|25.6|29.9<br>10.2||10.1||8.2||1.3| - 1) n = number of sub-bases (with MPA1, width 10 mm, max. 4 valve positions on sub-base; with MPA2, width 20 mm, max. 2 valve positions on sub-base) � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 48 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Technical data |**Dimensions**|**Dimensions**|||||Download CAD data �**www.festo.com**|Download CAD data �**www.festo.com**|Download CAD data �**www.festo.com**|Download CAD data �**www.festo.com**| |---|---|---|---|---|---|---|---|---|---| |Valve terminal with fiel||dbus connection|||||||| ||||||||||| ||||||||||| ||||||||||| ||||||||||| ||||||||||| ||||||||||| ||||||||||| ||||||||||| |1 <br>2 <br>3 <br>4|Solenoid valve MP<br> Solenoid valve MP<br> Manual override<br> Pilot air supply, pi<br>air|A1<br>A2<br>lot exhaust<br>5 Working ports<br>6 H-rail<br>7 H-rail mounting|8 Mounting holes<br>9 Pneumatic interface MPAF<br>aJ CPX module||||aA Earthing screw<br>aB Electrical supply plate||| ||||||||||| |Type|B1|B2<br>B3<br>B4<br>B6<br>B7|B8<br>B9<br>B10<br>B11||B12|B13|B14|B15<br>D1|D2| |MPA-F (FB)<br>178||149.3<br>135<br>107.3<br>65<br>66.3|26<br>18.9<br>23.5<br>17||27.7|7.5|6.6|4.4<br>M6|M4| ||||||||||| |Type<br>L1||L21)<br>L3<br>L4<br>L5<br>L6|L7<br>L8<br>L9|L10<br>L||11|L12<br>L|13<br>L14|L15| |MPA-F (FB)<br>86.1||n x 47.6<br>38.5<br>34.6<br>80.1<br>70.|5<br>50.1<br>31<br>23.7|22.5<br>2||2|21<br>1|6<br>10.5|8.4| ||||||||||| |Type<br>L16||L17<br>L18<br>H1<br>H2<br>H3|H4<br>H5<br>H6|H7<br>H||8|H9<br>H|10<br>H11|H12| |MPA-F (FB)<br>4||1.5<br>1<br>152<br>109<br>67.5|53.8<br>29.6<br>33.1|25.6<br>2||9.9|10.2<br>1|0.1<br>8.2|1.3| - 1) n = number of sub-bases (with MPA1, width 10 mm, max. 4 valve positions on sub-base; with MPA2, width 20 mm, max. 2 valve positions on sub-base) � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 49 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Accessories |**Ordering data**|**Ordering data**|**Ordering data**|**Ordering data**|**Ordering data**|**Ordering data**||| |---|---|---|---|---|---|---|---| |||||Code|Valve function|Width<br>[mm]|Part No.<br>Type| |Individual solenoid valve|||||||| |||||5/2-way valve|||| |||||M|Single solenoid|10|**533342**<br>**VMPA1-M1H-M-PI**| |||||||20|**8022034**<br>**VMPA2-M1BH-M-PI**| |||||MS|Single solenoid, mechanical spring return|10|**571334**<br>**VMPA1-M1H-MS-PI**| |||||||20|**571333**<br>**VMPA2-M1H-MS-PI**| |||||MU|Polymer poppet valve,<br>single solenoid, mechanical spring return|10|**553113**<br>**VMPA1-M1H-MU-PI**| |||||J|Double solenoid|10|**533343**<br>**VMPA1-M1H-J-PI**| |||||||20|**8022035**<br>**VMPA2-M1BH-J-PI**| |||||2x 3/2-way valve|||| |||||N|Normally open|10|**533348**<br>**VMPA1-M1H-N-PI**| |||||||20|**537958**<br>**VMPA2-M1H-N-PI**| |||||NS|Normally open, mechanical spring return|10|**556839**<br>**VMPA1-M1H-NS-PI**| |||||||20|**568655**<br>**VMPA2-M1H-NS-PI**| |||||NU|Polymer poppet valve,<br>normally open, mechanical spring return|10|**553111**<br>**VMPA1-M1H-NU-PI**| |||||K|Normally closed|10|**533347**<br>**VMPA1-M1H-K-PI**| |||||||20|**537957**<br>**VMPA2-M1H-K-PI**| |||||KS|Normally closed,<br>mechanical spring return|10|**556838**<br>**VMPA1-M1H-KS-PI**| |||||||20|**568656**<br>**VMPA2-M1H-KS-PI**| |||||KU|Polymer poppet valve, normally closed,<br>mechanical spring return|10|**553110**<br>**VMPA1-M1H-KU-PI**| |||||H|1x normally open,<br>1x normally closed|10|**533349**<br>**VMPA1-M1H-H-PI**| |||||||20|**537959**<br>**VMPA2-M1H-H-PI**| |||||HS|1x normally open,<br>1x normally closed,<br>mechanical spring return|10|**556840**<br>**VMPA1-M1H-HS-PI**| |||||||20|**568658**<br>**VMPA2-M1H-HS-PI**| |||||HU|Polymer poppet valve,<br>1x normally open,<br>1x normally closed,<br>mechanical spring return|10|**553112**<br>**VMPA1-M1H-HU-PI**| |||||5/3-way valve|||| |||||B|Mid-position pressurised|10|**533344**<br>**VMPA1-M1H-B-PI**| |||||||20|**8022036**<br>**VMPA2-M1BH-B-PI**| |||||G|Mid-position closed|10|**533345**<br>**VMPA1-M1H-G-PI**| |||||||20|**8022037**<br>**VMPA2-M1BH-G-PI**| |||||E|Mid-position exhausted|10|**533346**<br>**VMPA1-M1H-E-PI**| |||||||20|**8022038**<br>**VMPA2-M1BH-E-PI**| |||||3/2-way valve|||| |||||W|Normally open,<br>external compressed air supply|10|**540050**<br>**VMPA1-M1H-W-PI**| |||||||20|**8022040**<br>**VMPA2-M1BH-W-PI**| |||||X|Normally closed,<br>external compressed air supply|10|**534415**<br>**VMPA1-M1H-X-PI**| |||||||20|**8022039**<br>**VMPA2-M1BH-X-PI**| |||||2x 2/2-way valve|||| |||||D|Normally closed|10|**533350**<br>**VMPA1-M1H-D-PI**| |||||||20|**537960**<br>**VMPA2-M1H-D-PI**| |||||DS|Normally closed,<br>mechanical spring return|10|**556841**<br>**VMPA1-M1H-DS-PI**| |||||||20|**568657**<br>**VMPA2-M1H-DS-PI**| |||||I|1x normally closed,<br>1x normally closed, reversible|10|**543605**<br>**VMPA1-M1H-I-PI**| |||||||20|**543703**<br>**VMPA2-M1H-I-PI**| � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 50 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Accessories ## **Ordering data** |**ng data**|**ng data**|**ng data**|**ng data**|**ng data**|**ng data**|**ng data**| |---|---|---|---|---|---|---| ||Code|Description||Pressure regulation<br>range<br>[bar]|Part No.|Type| |torplate||||||| ||PF|MPA1, M5 interface, fixed|Port 1|0.5 … 5|**564911**|**VMPA1-B8-R1-M5-06**| ||PA|||0.5 … 8.5|**564908**|**VMPA1-B8-R1-M5-10**| ||PH||Port 2|2 … 5|**564912**|**VMPA1-B8-R2-M5-06**| ||PC|||2 … 8.5|**564909**|**VMPA1-B8-R2-M5-10**| ||PG||Port 4|2 … 5|**564913**|**VMPA1-B8-R3-M5-06**| ||PB|||2 … 8.5|**564910**|**VMPA1-B8-R3-M5-10**| ||PF|MPA1, M5 interface, rotatable|Port 1|0.5 … 5|**549052**|**VMPA1-B8-R1C2-C-06**| ||PA|||0.5 … 8.5|**543339**|**VMPA1-B8-R1C2-C-10**| ||PH||Port 2|2 … 5|**549053**|**VMPA1-B8-R2C2-C-06**| ||PC|||2 … 8.5|**543340**|**VMPA1-B8-R2C2-C-10**| ||PG||Port 4|2 … 5|**549054**|**VMPA1-B8-R3C2-C-06**| ||PB|||2 … 8.5|**543341**|**VMPA1-B8-R3C2-C-10**| ||PF|MPA2, 10 mm cartridge fitting|Port 1|0.5 … 5|**549055**|**VMPA2-B8-R1C2-C-06**| ||PA|||0.5 … 8.5|**543342**|**VMPA2-B8-R1C2-C-10**| ||PH||Port 2|2 … 5|**549056**|**VMPA2-B8-R2C2-C-06**| ||PC|||2 … 8.5|**543343**|**VMPA2-B8-R2C2-C-10**| ||PG||Port 4|2 … 5|**549057**|**VMPA2-B8-R3C2-C-06**| ||PB|||2 … 8.5|**543344**|**VMPA2-B8-R3C2-C-10**| ||PN|MPA2, reversible, 10 mm cartridge<br>fitting|Port 2|0.5 … 5|**549113**|**VMPA2-B8-R6C2-C-06**| ||PL|||0.5 … 8.5|**543347**|**VMPA2-B8-R6C2-C-10**| ||PM||Port 4|0.5 … 5|**549114**|**VMPA2-B8-R7C2-C-06**| ||PK|||0.5 … 8.5|**543348**|**VMPA2-B8-R7C2-C-10**| |||||||| |lpressure shut-offplate||||||| ||PS|MPA1, port 1 and 12/14, operating pressure 3.0 … 8.0 bar|||**567805**|**VMPA1-HS**| |||||||| |regauge for regulatorplate||||||| ||VE|MPA1, with thread M5, rotatable|Display unit<br>bar|0.5 … 8.5|**132340**|**MA-15-10-M5**| ||VD||Display unit<br>psi|0.5 … 8.5|**132341**|**MA-15-145-M5-PSI**| ||T|MPA2, 10 mm cartridge fitting<br>connection|Display unit<br>bar/psi|0.5 … 8.5|**543487**|**PAGN-26-16-P10**| |||||0.5 … 5|**543488**|**PAGN-26-10-P10**| |||||||| |ed adapter||||||| ||–|For MPA2 regulator, 10 mm cartridge fitting connection to thread G1/8|||**565811**|**QSP-10-G1/8**| |||||||| |turn valve||||||| ||–|For MPA1 with thread M5, fixed|||**153291**|**QSK-M5-4**| � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 51 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Accessories |**ng data**|**ng data**|**ng data**||| |---|---|---|---|---| |ation|||Width<br>[mm]|Part No.<br>Type| |se – Without electrical interlinkingmodule||||| ||For multi-pin plug/fieldbus|Four valve positions|10|**544402**<br>**VMPAF-AP-4-1**| |||Two valve positions|20|**544403**<br>**VMPAF-AP-2-2**| ||For multi-pin plug/fieldbus, duct 1 closed|Four valve positions|10|**547504**<br>**VMPAF-AP-4-1-T1**| |||Two valve positions|20|**547505**<br>**VMPAF-AP-2-2-T0**| |||||| |se – Incl. electrical interlinkingmodule and electronics module||||| ||For fieldbus|Four valve positions|10|**547492**<br>**VMPAF-AP-4-1-EMS-8**| |||Two valve positions|20|**547493**<br>**VMPAF-AP-2-1-EMS-4**| ||For multi-pin plug|Eight solenoid coils<br>|10|**547494**<br>**VMPAF-AP-4-1-EMM-8**<br>| |||Four solenoid coils|20|**547495**<br>**VMPAF-AP-2-1-EMM-4**| |||Four solenoid coils|10|**547496**<br>**VMPAF-AP-4-1-EMM-4**| |||Two solenoid coils|20|**547497**<br>**VMPAF-AP-2-1-EMM-2**| |||||| |and endplate||||| ||Right-hand end plate, with selector switch for operation with internal or<br>supply||external pilot air|**544401**<br>**VMPAF-FB-EPR**| |||||| |al interface for multi-pin plug connection||||| ||Without exhaust plate, without flat plate silencer|||**544400**<br>**VMPAF-MPM-EPL**| |||||| |atic interface for CPXplastic interlinkingmodule||||| ||Without exhaust plate, without flat plate silencer|||**544399**<br>**VMPAF-FB-EPL**| ||Without exhaust plate, without flat plate silencer, with integrated pressure sensor for duct 1|||**547491**<br>**VMPAF-FB-EPL-PS**| |||||| |atic interface for CPX metal interlinkingmodule||||| ||Without exhaust plate, without flat plate silencer|||**552279**<br>**VMPAF-FB-EPLM**| ||Without exhaust plate, without flat plate silencer, with integrated pressure sensor for duct 1|||**552280**<br>**VMPAF-FB-EPLM-PS**| |||||| |al supply plate||||| ||Plug connection M18, 3-pin|||**545349**<br>**VMPAF-FB-SP-V**| ||Plug connection 7/8†, 5-pin|||**545351**<br>**VMPAF-FB-SP-7/8-V-5POL**| ||Plug connection 7/8†, 4-pin|||**545350**<br>**VMPAF-FB-SP-7/8-V-4POL**| |||||| |re sensor||||| ||For monitoring the operating pressure in duct 1|||**545352**<br>**VMPAF-FB-PS-1**| ||For monitoring the pressure in exhaust ducts 3 and 5|||**545353**<br>**VMPAF-FB-PS-3/5**| ||For monitoring an external process pressure|||**545354**<br>**VMPAF-FB-PS-P1**| � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 52 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Accessories |**g data**|||||| |---|---|---|---|---|---| |ation|||Width<br>[mm]|Part No.|Type| |nics module|For fieldbus connection||||| ||Without separate circuit|4 coils|20|**537983**|**VMPA2-FB-EMS-4**| |||8 coils|10|**533360**|**VMPA1-FB-EMS-8**| ||With separate circuit|4 coils|20|**537984**|**VMPA2-FB-EMG-4**| |||8 coils|10|**533361**|**VMPA1-FB-EMG-8**| ||For fieldbus connection with extended diagnostic function||||| ||Without separate circuit|4 coils|20|**543332**|**VMPA2-FB-EMS-D2-4**| |||8 coils|10|**543331**|**VMPA1-FB-EMS-D2-8**| ||With separate circuit|4 coils|20|**543334**|**VMPA2-FB-EMG-D2-4**| |||8 coils|10|**543333**|**VMPA1-FB-EMG-D2-8**| ||For multi-pin plug connection||||| ||Modular (MPM)|2 coils|20|**537985**|**VMPA2-MPM-EMM-2**| |||4 coils|20|**537986**|**VMPA2-MPM-EMM-4**| |||4 coils|10|**537987**|**VMPA1-MPM-EMM-4**| |||8 coils|10|**537988**|**VMPA1-MPM-EMM-8**| ||||||| |al interlinking|module for multi-pinplugconnection||||| ||For a sub-base|2 coils<br>|20<br>|**544413**<br>|**VMPAF-MPM-EV-AP-2**<br>| |||4 coils|10<br>20|**544414**|**VMPAF-MPM-EV-AP-4**| |||8 coils|10|**544515**|**VMPAF-MPM-EV-AP-8**| ||For a pneumatic supply plate VMPAF-FB-SP-P (power supply module)|||**544416**|**VMPAF-MPM-EV-SP**| ||||||| |al interlinking|module for fieldbus connection||||| ||For a sub-base|||**544417**|**VMPAF-FB-EV-AP**| ||For pneumatic supply plate|||**544418**|**VMPAF-FB-EV-SP-P**| ||For electrical supply plate or pressure sensor|||**544419**|**VMPAF-FB-EV-SP-E**| ||||||| |inplugconnection, electrical|||||| ||Cover without connecting cable for self-assembly|||**533198**|**VMPA-KMS-H**| ||PVC connecting cable for 8 solenoid coils|2.5 m||**533195**|**VMPA-KMS1-8-2,5**| |||5 m||**533196**|**VMPA-KMS1-8-5**| |||10 m||**533197**|**VMPA-KMS1-8-10**| ||PVC connecting cable for 24 solenoid coils|2.5 m||**533192**|**VMPA-KMS1-24-2,5**| |||5 m||**533193**|**VMPA-KMS1-24-5**| |||10 m||**533194**|**VMPA-KMS1-24-10**| ||PUR connecting cable for 8 solenoid coils,<br>suitable for energy chains|2.5 m||**533504**|**VMPA-KMS2-8-2,5-PUR**| |||5 m||**533505**|**VMPA-KMS2-8-5-PUR**| |||10 m||**533506**|**VMPA-KMS2-8-10-PUR**| ||PUR connecting cable for 24 solenoid coils,<br>suitable for energy chains|2.5 m||**533501**|**VMPA-KMS2-24-2,5-PUR**| |||5 m||**533502**|**VMPA-KMS2-24-5-PUR**| |||10 m||**533503**|**VMPA-KMS2-24-10-PUR**| ||||||| |ng|||||| ||For H-rail, MPAF with fieldbus|||**560798**|**VMPAF-FB-BG-NRH**| ||For H-rail, MPAF with multi-pin plug connection|||**526032**|**CPX-CPA-BG-NRH**| ||Mounting bracket|||**544420**|**VMPAF-BG-RW**| � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 53 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Accessories |**g data**|||| |---|---|---|---| |ation|||Part No.<br>Type| ||||| ||Blanking plate for valve position1)||**533351**<br>**VMPA1-RP**| ||||**537962**<br>**VMPA2-RP**| ||Cover for manual override, non-detenting (10 pieces)||**540897**<br>**VMPA-HBT-B**| ||Cover for manual override, covered (10 pieces)||**540898**<br>**VMPA-HBV-B**| ||||| |tingseals for manifold block|||| ||Separating seal|No duct separation|**544406**<br>**VMPAF-DP**| |||Duct 1 separated|**544407**<br>**VMPAF-DP-P**| |||Duct 3/5 separated|**544408**<br>**VMPAF-DP-RS**| |||Duct 1 and 3/5 separated|**544409**<br>**VMPAF-DP-PRS**| ||||| |tplate|||| ||For left-hand end plate or power supply module, for ducted exhaust air, ducts 3/5 common||**544411**<br>**VMPAF-AP-1**| ||For left-hand end plate or power supply module, for ducted exhaust air, duct 3 and duct 5<br>separated||**544412**<br>**VMPAF-AP-2**| ||||| |upplymodule|||| ||Without silencer, without exhaust plate||**544404**<br>**VMPAF-SP-P**| ||||| |g plug|||| ||Thread M7<br>(10 pieces)||**174309**<br>**B-M7**| ||Thread G¼<br>(10 pieces)||**3569**<br>**B-**¼| ||Thread G½<br>(10 pieces)||**3571**<br>**B-**½| - 1) A self-adhesive label is supplied. � **Internet: www.festo.com/catalogue/...** Subject to change – 2016/09 54 -U- **Type discontinued Available up until 2019** ## **Valve terminals MPA-F** Accessories |**ring data**|**ring data**||| |---|---|---|---| |gnation|||Part No.<br>Type| |-in fittingfor manifold block,pneumatic interface, supply plate|||| ||Connecting thread M7 for tubing O.D.|4 mm (10 pieces)|**153319**<br>**QSM-M7-4-I**| |||3/16" (1 piece)|**183739**<br>**QSM-M7-3/16-I-U-M**| |||6 mm (10 pieces)|**153321**<br>**QSM-M7-6-I**| |||1/4" (50 pieces)|**183740**<br>**QSM-M7-1/4-I-U-M**| ||Connecting thread G¼for tubing O.D.|8 mm (10 pieces)|**186110**<br>**QS-G**¼**-8-I**| |||5/16" (1 piece)|**183743**<br>**QS-1/4-5/16-I-U-M**| |||10 mm (10 pieces)|**186112**<br>**QS-G**¼**-10-I**| |||3/8" (1 piece)|**183744**<br>**QS-1/4-3/8-I-U-M**| ||Connecting thread G½for tubing O.D.|12 mm (1 piece)|**186104**<br>**QS-G1/2-12**| |||1/2" (1 piece)|**183748**<br>**QS-1/2-1/2-I-U-M**| |||16 mm (1 piece)|**186105**<br>**QS-G1/2-16**| ||||| |cer|||| ||Flat plate silencer for left-hand end plate or power supply module||**544410**<br>**VMPAF-APU**| ||Silencer, connecting thread G¼||**165004**<br>**UC-**¼| ||||| |iption label holder|||| ||Retainer for inscription label holder, 10 pieces||**544421**<br>**VMPAF-STH**| ||Inscription label holder for manifold block, for IBS, 10 pieces||**544422**<br>**VMPAF-ST1**| ||Inscription label holder for manifold block, transparent, for paper foil label, 10 pieces||**546228**<br>**VMPAF-ST1T**| ||||| |iption label|||| ||Inscription label 9 x 20, 20 labels in frames||**18182**<br>**IBS-9x20**| ||||| |ual|||| ||MPA-F pneumatic components|German|**547525**<br>**P.BE-MPAF-DE**| |||English|**547526**<br>**P.BE-MPAF-EN**| |||French|**547528**<br>**P.BE-MPAF-FR**| |||Spanish|**547527**<br>**P.BE-MPAF-ES**| |||Italian|**547529**<br>**P.BE-MPAF-IT**| |||Swedish|**547530**<br>**P.BE-MPAF-SV**| ||MPA electronic components<br>(pneumatic modules, pressure sensors, proportional<br>pressure regulators, etc.)|German|**562112**<br>**P.BE-MPA-Elektronik-DE**| |||English|**562113**<br>**P.BE-MPA-Elektronik-EN**| |||French|**562115**<br>**P.BE-MPA-Elektronik-FR**| |||Spanish|**562114**<br>**P.BE-MPA-Elektronik-ES**| |||Italian|**562116**<br>**P.BE-MPA-Elektronik-IT**| � **Internet: www.festo.com/catalogue/...** 2016/09 – Subject to change 55
Updated at June 9, 2026
Festo is a globally recognized leader in industrial automation, renowned for its innovative pneumatic and electrical control and drive technologies. As an engineering-driven company, Festo provides robust, high-quality components designed to optimize both factory and process automation systems across a wide range of demanding industries. A cornerstone of their automation expertise is a comprehensive portfolio of precision sensory technology. The core of this offering is focused on advanced pressure sensors and transducers. These vital components are engineered to deliver highly accurate fluid and gas measurements, ensuring reliable monitoring, system safety, and optimal efficiency in complex industrial environments. Complementing their fluid control solutions, Festo also manufactures a dependable selection of proximity sensors and proximity switches. Built for durability and precise object detection, these sensors provide the essential positional feedback required to maintain seamless and automated operational workflows.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.