555480
P.BE-CPX-CMPX-SYS-EN DESCRIPTION
- Manufacturer: FESTO
- Product type: Controller Accessories
- SVHC: No SVHC (25-Jun-2020)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 109.87 € |
| Current stock | 10+ |
| Lead time | 30 days |
# **Modular electrical terminal CPX**
Terminal CPX
## Key features
- **Key features** Installation concept Electrics Mounting
- • Choice of several valve terminals for • High operating voltage tolerance • Wall or H-rail mounting, also on modifferent applications: (±25%) bile units – MPA-S • Choice of M12x1, M18, 7/8" or AIDA • Conversions/extensions are possi– MPA-L push-pull connection for power supble at any time, individual linking – VTSA/VTSA-F/VTSA-F-CB ply with CPX metal design
- • Economical from the smallest con• Open to all fieldbus protocols and • Modular system offering a range of figuration up to the maximum numEthernet configuration options ber of modules • Optional function and technology • Fully assembled and tested unit
- • Up to 9 electrical input/output modmodules for preprocessing • Reduced costs for selection, orderules plus bus node and pneumatic • IT services and TCP/IP such as reing, assembly and commissioning interface/electronics modules for mote maintenance, remote diagnosthanks to the central CPX terminal valves tics, web server, SMS and e-mail • Choice of pneumatic components
- • Extensive range of functions and alert for optimised control chain
- Mounting Operation
- • Wall or H-rail mounting, also on mobile units
- Fast troubleshooting thanks to an extensive selection of LEDs (some of which are multi-coloured) on the bus node and on all I/O modules
- Supports module and channel-oriented diagnostics
- Modular system offering a range of configuration options
- Fieldbus/Ethernet remote diagnostics
- Innovative diagnostic support with integrated web server/web monitor or maintenance tool with USB adapter for PC
- Reduced costs for selection, ordering, assembly and commissioning thanks to the central CPX terminal
- Optimised commissioning thanks to parameterisable functions
- Extensive range of functions and connection options for the electrical modules
- Digital inputs and outputs, 4-/8/16-way, optionally available with individual channel diagnostics
- Decentralised, subordinate CPI installation system improves cycle times by up to 30%
- Reliable servicing with connection blocks and modules that are quick to replace without changing the wiring
- Choice of connection technology for technically and economically optimised connections
- Safe and convenient earthing thanks to earthing plate
- Analogue inputs and outputs, 2-way/4-way, optionally with HART protocol
- Can be used as a dedicated remote I/O module
- Pressure inputs
- Temperature inputs
- Controllers for pneumatic and electric axes
- IP65 and IP67 or IP20
Subject to change – 2023/10
2
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Key features
## **Pneumatic variants of the CPX terminal**
The electrical terminal CPX is a modular peripheral system for valve terminals.
With valve terminal – decentralised
With valve terminal VTSA – centralised
The system is specifically designed so that the valve terminal can be adapted to suit a wide range of different applications.
The modular system design lets you configure the number of valves, inputs and additional outputs to suit the application.
**==> picture [125 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
With valve terminal MPA-S – centralised<br>**----- End of picture text -----**<br>
In metal design with valve terminal VTSA – centralised
2023/10 – Subject to change
3
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Key features
**Variants of the CPX terminal controller (with bus node, without preprocessing)** Bus node
Different bus nodes are used for integration in the control systems of various manufacturers.
Integration in universal networks based on Ethernet opens up new possibilities. Faster data transmission, real-time capability and above all additional IT services such as file transfer, web server, web monitor as integrated website in the CPX terminal, text message/e-mail alerts, etc. open up a wide range of synergies.
The CPX terminal can therefore be operated on over 90% of the most commonly used fieldbus systems:
- PROFIBUS DP
- PROFINET
- DeviceNet
These include standardised and uni-
- CANopen
- CC-Link
- versal communication technology
**==> picture [192 x 87] intentionally omitted <==**
**----- Start of picture text -----**<br>
Bus node<br>1<br>2<br>**----- End of picture text -----**<br>
- [1] Higher-order controller (PLC)
- Communication with the higher-order controller via fieldbus
- [2] Fieldbus
- No preprocessing
- Fieldbus protocol dependent on CPX bus node used
- More than 90 I/Os, depending on bus node used
The following protocols are supported:
across all areas, including operating level, management level and field level in the production environment, with protection to IP65, IP67.
- EtherNet/IP
- Modbus/TCP
- PROFINET
- POWERLINK
- EtherCAT
- Sercos III
Industrial Ethernet bus node
**==> picture [56 x 129] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>2<br>-<br>3<br>a |<br>**----- End of picture text -----**<br>
- [1] Higher-order controller (PLC)
- Connection to a higher-order controller directly via EtherNet/IP, Modbus/TCP, POWERLINK, EtherCAT or PROFINET
- [2] Fieldbus
- [3] IT services:
- Web
- Email
- No preprocessing
- Monitoring via Ethernet and web applications
- Data transmission
- More than 300 I/Os
- **Note** H- Every electrical interface can be combined with an appropriate number of I/O modules and/or pneumatic components, depending on its address capacity.
Likewise, every pneumatic variant of the CPX terminal can be operated with every electrical interface variant.
Subject to change – 2023/10
d **Internet: www.festo.com/catalogue/...**
4
Terminal CPX
## Key features
## **Variants of the CPX terminal controller (with preprocessing in the control block)** Control block
The optional front end controllers CPXAccess via Modbus/TCP and EasyIP is Commissioning, programming, and diCEC enable simultaneous access via also possible. agnostics using the Festo software tool Ethernet, in parallel with a bus node, FST with hardware configurator. as well as stand-alone preprocessing. With control block in stand-alone mode With control block in Festo EasyIP mode 1 ~~" 1 L~~ L] ~~L~~ | eee ES ~~2~~
- [1] CODESYS/FST
- Decentralised controller with direct [1] Industrial Ethernet machine mounting [2] IT services:
- Downloading programs via Ethernet (or via the programming interface)
- Web
- Email
- Supports full expansion of all CPX peripherals
- Data transmission
- More than 300 I/Os
Can be successfully used in the follow applications:
- Fast preprocessing of the CPX peripherals in the control block
- Exchange of any data between the control blocks via EasyIP
- Remote diagnostics
- No higher-order controller is required
- More than 300 I/Os per CPX control block
- Stand-alone individual workstations
- Interlinked, stand-alone sub-systems
- Automation using IT technology
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
5
Terminal CPX
## Key features
**Variants of the CPX terminal controller (with preprocessing in the control block)** With control block as remote controller on Ethernet
Remote controller via Ethernet as the
preprocessing unit for decentralised,
stand-alone sub-systems using IT technology.
With control block as remote controller on the fieldbus
Fieldbus remote controller (combination with bus nodes for PROFIBUS DP, PROFINET, CANopen, DeviceNet, CCLink, POWERLINK, Sercos III or EtherCAT) as the preprocessing unit for decentralised, stand-alone subsystems.
**==> picture [369 x 176] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 1<br>2 a [ 7 2 a<br>3 : :<br>LS 3 4<br>IP QU —<br>**----- End of picture text -----**<br>
- [1] Higher-order controller (PLC)
- [2] Industrial Ethernet
- [3] IT services:
- Web
- Email
- Data transmission
- Connection to a higher-order controller via Ethernet, no further bus node is required
- Monitoring via Ethernet and web applications
- Preprocessing of the CPX peripherals by CPX control block
- More than 300 I/Os
- [1] Higher-order controller (PLC)
- [2] Fieldbus
- [3] Industrial Ethernet
- [4] IT services:
- Web
- Email
- Data transmission
- Fast preprocessing of the CPX peripherals in the control block
- Communication with the higher-order controller via fieldbus
- Optional additional monitoring via Ethernet and web applications
- Downloading programs via programming interface
- More than 300 I/Os, bus node is only used for communication with the higher-order PLC
- Option of two bus nodes for redundant communication configuration
Subject to change – 2023/10
6
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features
**Variants of the CPX terminal controller (with preprocessing in the control block)** With control block as CANopen fieldbus master
**==> picture [213 x 195] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>2<br>3<br>4<br>**----- End of picture text -----**<br>
- [1] Higher-order controller (PLC)
- [2] Industrial Ethernet
- [3] IT services:
- Web
- Email
- Data transmission
- [4] Fieldbus (CANopen)
## Features:
- Connection to a higher-order controller via Ethernet, no further bus node is required
- Monitoring via Ethernet
- Preprocessing of the CPX peripherals by CPX control block
- More than 300 I/Os
- Up to 128 stations with repeater technology on CANopen
## Operating modes:
- Remote controller on Ethernet
- Control block in Festo EasyIP mode
**==> picture [250 x 91] intentionally omitted <==**
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
7
Terminal CPX
## Key features
**Connection of inputs and outputs to the CPX terminal** Digital and analogue CPX I/O modules
## Electrical connection
The connection technology for sensors and additional actuators offers a wide range of digital and analogue input and output modules and is freely selectable – as appropriate to your standard or the application. Plastic or metal connection blocks can be combined as required:
- Metal version – M12-5POL
- Plastic version:
- M12-5POL
- M12-5-PIN with quick lock and metal thread
- M12-8POL
- M8-3POL
- M8-4POL
- Sub-D
- CageClamp[®] (with cover also to IP65, IP67)
- Screw/spring-loaded terminal
**==> picture [67 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
With CPX-CP interface<br>**----- End of picture text -----**<br>
- Up to 4 strings per CP interface possible.
- Up to 4 subordinate CP modules can be combined in one string.
- Up to 32 I/Os can be connected per string.
- Modules with M8, M12 and terminal connection
- Several CP interface modules can be combined in one CPX terminal (depending on the controller used).
- Combination of centralised CPX I/O modules and decentrally mounted I/O modules of the installation system CPI.
Combined centralised and decentralised electrical connection (valve terminal with CP interface/output module)
- Scalable to different requirements within a system
- One control interface in the system, reduces installation complexity with closely and widely spaced actuators
- Enables an optimum electrical and pneumatic control chain
Subject to change – 2023/10
8
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Key features
## **Connection of inputs and outputs to the CPX terminal**
With CPX-CTEL interface
- Up to 4 devices with individual elecSeveral CPX CTEL masters can be comtronic protection per CPX CTEL masbined on one CPX terminal (depending ter on the controller used).
- • Max. 64 inputs/64 outputs per Combination of central CPX I/O modI-Port interface ules and decentrally mounted I/O
- • The maximum length of a string is modules with I-Port interface. 20 m.
**==> picture [63 x 33] intentionally omitted <==**
**----- Start of picture text -----**<br>
: 224522208)<br>29%. 52 2260u<br>SS. eee<br>: as<br>12/14 82/84<br>11 3/5<br>1<br>3G 3G 3G 3G 5J 5J 5J 5J<br>**----- End of picture text -----**<br>
- Input modules with 16 digital inputs (connection technology M8 3-pin and M12 5-pin)
- Valve terminals with I-Port interface (up to 48 solenoid coils, different valve functions)
With CPX-CTEL-2 interface
- Up to 2 IO-Link devices with individSeveral CPX-CTEL-2 interfaces can be ual electronic protection per CPXcombined on one CPX terminal (deCTEL-2 interface pending on the controller used).
- • Max. 16-byte inputs/16-byte outCombination of central CPX I/O modputs per IO-Link device ules and decentrally mounted I/O
- • The maximum length of a string is modules with IO-Link interface. 20 m.
2023/10 – Subject to change
9
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Key features
## **Connection of inputs and outputs to the CPX terminal**
Electric drives with axis interface CPX-CM-HPP
- Max. 4 individual electric axes pos• Standardised communication with • The control component is independsible per CPX-CM-HPP the drives via the Festo Handling ent of the bus node used
- • No programming required and Positioning Profile (FHPP)
- Pneumatic drives with CPX-CMAX/CMPX
## CPX-CMAX
- Position and force control, directly actuated or selected from one of 64 configurable positioning sets
- The configurable record sequencing function enables simple functional sequences to be realised
- Auto identification detects every station with its device data on the controller
- Control of a brake or clamping unit via the proportional directional control valve VPWP
- Up to 7 modules (max. 7 axes) can be operated in parallel and independently of each other
- Commissioning via the Festo configuration software FCT or via fieldbus
## CPX-CMPX
- Fast travel between the mechanical end stops of the cylinder, stopping gently and without impact in the end position
- Fast commissioning via control panel, fieldbus or handheld terminal
- Improved downtime control
- Control of a brake or clamping unit via the proportional directional control valve VPWP
- Max. 9 end-position controllers can be actuated depending on the fieldbus
- All system data can be read and written via the fieldbus, including the mid-positions, for example:
Subject to change – 2023/10
10
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features
## **Ordering**
The CPX terminal with valve terminal is fully assembled according to your order specifications and individually tested. The finished valve terminal consists of the electrical peripherals including the desired actuation and the selected components of the VTSA (ISO), VTSA-F, VTSA-F-CB, MPA-S or MPA-L modules. The CPX terminal with valve terminal is ordered using two separate order codes.
One order code defines the electrical peripherals type CPX, while the other specifies the pneumatic components of the valve terminal.
The electrical peripherals type CPX can also be configured without a valve terminal and can be used on a fieldbus. To order this, only the order code for the electrical peripherals is required.
The order lists for the pneumatic components can be found at a Internet: vtsa (Valve terminal VTSA) a Internet: vtsa-f (Valve terminal VTSA-F) a Internet: vtsa-f-cb (Valve terminal VTSA-F-CB) a Internet: mpa-s (Valve terminal MPA-S) a Internet: mpa-l (Valve terminal MPA-L)
The order lists for the CP/CPI components can be found at a Internet: cpi (Installation system CPI)
The order lists for the CTEU/CTEL components can be found at a Internet: cteu (I-Port interface/IO-Link)
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
11
Terminal CPX
## Peripherals overview
|Designation<br>[1]<br>Earthingcomponent|Type<br>CPX-EPFE-EV|Description<br>aPage/Internet<br>For right/left endplate<br>52|Page/Internet|
|---|---|---|---|
|[2]<br>End plate|CPX-EP|• Mounting holes for wall mounting<br>• Functional earth connection<br>• Special earthing plate for safe and easy connection to the machine bed or H-rail<br>• Externalpower supplyfor the entire system<br>52||
|[3]<br>Busknoten<br>Control block<br>Gateway|CPX-FB<br>CPX-M-FB|• Fieldbus/Industrial Ethernet connection using various types of connection technology<br>• Setting fieldbus parameters via DIL switch<br>• Display of fieldbus and peripheral equipment status via LED<br>• PROFINET to AIDA standard in metal housing, fast start-up<br>72||
||CPX-CEC|• Preprocessing, stand-alone controller or remote unit CPX-CEC<br>• Connection via Ethernet TCP/IP or Sub-D programming interface<br>• Setting operating modes via DIL switch and program selection via rotary switch<br>• CPX-CMXproducts for controllingaxes<br>65||
||CPX-IOT|• Separate CPX combination<br>• Data gathering for connected components<br>• Secure data transfer to a central storage location (MQTT broker)<br>58||
|[4]<br>Plastic interlinking block<br>Interlinking block, metal|CPX-GE|• Internal linking of the power supply and serial communication<br>• External power supply for the entire system or for outputs or valves<br>• Connection accessories for M18, 7/8"<br>• Linkingwith tie rods<br>51||
||CPX-M-GE|• Internal linking of the power supply and serial communication<br>• External power supply for the entire system or for outputs<br>• Transmission of the power supply<br>• Connection accessories for M12x1, 7/8" or AIDA push-pull<br>• Individual linking with M6 screws, individually expandable<br>51||
Subject to change – 2023/10
12
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Peripherals overview
**==> picture [523 x 615] intentionally omitted <==**
**----- Start of picture text -----**<br>
Designation Type Description a Page/Internet<br>[5] Electronics module CPX-4DE Input module with 4 digital inputs, positive logic (PNP) 145<br>CPX-8DE Input module with 8 digital inputs, positive logic (PNP)<br>CPX-8DE-D Input module with 8 digital inputs, positive logic (PNP), enhanced diagnostic function<br>CPX-8NDE Input module with 8 digital inputs, negative logic (NPN)<br>CPX-P-8DE-N NAMUR input module with 8 digital inputs 150<br>CPX-F8DE-P PROFIsafe input module with 8 digital inputs 154<br>CPX-16DE Input module with 16 digital inputs, internal electronic fuse per module 160<br>CPX-M-16DE-D Input module with 16 digital inputs, internal electronic fuse per channel pair, for CPX in<br>metal<br>CPX-4DA Output module with 4 digital outputs, 1 A per channel 166<br>CPX-8DA Output module with 8 digital outputs, 0.5 A per channel<br>CPX-8DA-H Output module with 8 digital outputs, 2.1 A per channel pair<br>CPX-8DE-8DA Input/output module with 8 digital inputs and 8 digital outputs 172<br>CPX-2ZE2DA Counter module with 2 digital inputs and 2 digital outputs 177<br>CPX-4AE-4AA-H HART input/output module with 4 analogue input/outputs 181<br>CPX-2AE-U-I Input module with 2 analogue current and/or voltage inputs 186<br>CPX-4AE-U-I Input module with 4 analogue current and/or voltage inputs<br>CPX-4AE-I Input module with 4 analogue current inputs<br>CPX-4AE-T Input module for temperature inputs 193<br>CPX-4AE-TC Input module for temperature inputs with cold junction compensation 197<br>CPX-2AA-U-I Output module with 2 analogue current or voltage outputs 201<br>CPX-FVDA-P2 PROFIsafe shut-off module for shutting off the supply voltage for valves, with two digital 205<br>outputs<br>[6] Plastic connection block CPX-AB • Choice of 8 connection technology variants –<br>• Degree of protection IP65, IP67 or IP20<br>• Can be combined with the electronics modules<br>• Connection accessories for M8/M12/Sub-D<br>• M8/M12/Sub-D, etc. connecting cables<br>• Modular system for M8/M12 connecting cables<br>[7] Connection block including electronics CPX-L • Spring-loaded terminal –<br>module and interlinking block • Degree of protection IP20<br>• Digital input module with 16 inputs<br>• Digital I/O module with 8 inputs and 8 outputs<br>• Plastic connection block<br>[8] Analogue electronics module for CPX-4AE-P • Pneumatic connection QS-4 191<br>pressure inputs • Degree of protection IP 65, IP67<br>• 4 analogue pressure inputs (0 ... 10 bar, –1 ... +1 bar)<br>[9] CP interface CPX-CP • Interfaces for decentralised installation systems, thus optimising the pneumatic 117<br>CTEL interface CPX-CTEL control chains (short tubes/short cycle times) 122<br>• Actuation for I/O modules and valve terminals<br>• Power supply and bus interface via the same cable<br>• M9, M12 connection technology<br>• Degree of protection IP 65, IP67<br>[10] Metal connection block CPX-M-AB • Can be combined with the electronics modules –<br>• Connection technology M12x1, 5-pin<br>• Degree of protection IP 65, IP67<br>• Connection accessories for M12<br>• Connecting cable M12,<br>• Modular system for choice of connecting cables M12<br>[11] Pneumatic interface VTSA VABA-S6 • Control of valve terminal VTSA/VTSA-F/VTSA-F-CB 236<br>• Control of pressure sensors<br>[12] Pneumatic interface MPA-S VMPA-FB • Control of valve terminal MPA-S 231<br>• Control of pressure sensors<br>• Control of proportional pressure regulators<br>[13] Pneumatic interface MPA-L VMPAL-EPL-CPX Control of valve terminal MPA-L 234<br>[14] Web monitor – • Website integrated in the CPX terminal –<br>• Dynamic status indication<br>• Online diagnostics and SMS/e-mail alert<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
13
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Peripherals overview
**==> picture [461 x 572] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|Individual overview of modules|
|Bus node|a|Page 72|
|Bus node for|• PROFINET|
|• PROFIBUS DP|• POWERLINK|
|• DeviceNet|• EtherCAT|
|• CANopen|• Sercos III|
|• CC-Link|
|2|22>|
|• EtherNet/IP|
|A|
|Control block|a|Page 65|
|CPX-CEC|
|• Programming with CODESYS|
|• Ethernet interface|
|• Modbus/TCP|
|• EasyIP|
|• CANopen master|
|ee|
|Gateway|a|Page 58|
|CPX-IOT|
|• Continuous transfer of operating|
|RS|data from connected Festo compo-|
|nents to a central storage location|
|iN|
|(user-specific MQTT broker)|
|• Ethernet interface|
|Ay|
|ai|ff|
|E|ww|
|CP interface|a|Page 117|
|Interface CPX-CP|
|• 4 CP strings|
|• Max. 4 modules per string|
|• 32 inputs/32 outputs per string|
|nN|
|• CPI functionality|
|Dj Ext|
|WS|
|CTEL interface|a|Page 122|Electrical interface CPX-CTEL-2|a|Page 128|
|CPX-CTEL interface|CPX-CTEL-2 interface|
|• CTEL master|can|• Master for IO-Link|
|• Max. 4 devices with individual elec-|=|
|Se|tronic protection|=|tronic protection|
|• Max. 64 inputs/64 outputs per|Zi|
|I-Port interface|
|<P|
**----- End of picture text -----**<br>
- Max. 2 devices with individual electronic protection
- Process data length of the inputs and outputs is limited to 16 bytes for inputs and 16 bytes for outputs per port
- The maximum length of a string is 20 m
- The maximum length of a string is 20 m
Subject to change – 2023/10
d **Internet: www.festo.com/catalogue/...**
14
Terminal CPX
## Peripherals overview
## **Individual overview of modules**
Modules for actuating electric drive units
a Page 133
## CPX-CM-HPP
- Axis interface
- CAN bus for up to 4 individual electric axes
Modules for controlling pneumatic drive units
## CPX-CMAX
## CPX-CMPX
- End-position controller
- Axis controller
- Fast travel between the mechanical end stops of the cylinder
- Position and force control
- 64 configurable positioning records
- Auto-identification
- Smooth travel into the end position
- Control of a brake or clamping unit • Improved downtime control via the proportional directional con• Control of a brake via the proportrol valve VPWP tional directional control valve VPWP
## a Page 136
## CPX-CMIX
- Measuring module
- CAN input (Festo specification) for measuring signal
- Recording the absolute position values or speed values of the connected drive
## Plastic connection block
Direct machine mounting Protected fitting space (degree of protection IP65, IP67) (degree of protection IP20)
- Spring-loaded terminal
- M8-3POL
- M8-4POL
## Shielding concept
- Optional screening plate for connection blocks with M12 connection technology
- M12-5POL
- M12-5POL quick lock, shielded with metal thread
- M12-8POL
- Sub-D
- Spring-loaded terminal with cover
## Metal connection block
Direct machine mounting (degree of protection IP65, IP67) • M12-5POL
Connection block including electronics module and interlinking block
Installation in the control cabinet (degree of protection IP20)
- Plastic connection block
- Spring-loaded terminal
- Digital input module with 16 inputs
- Digital I/O module with 8 inputs and 8 outputs
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
15
Terminal CPX
## Peripherals overview
## **Individual overview of modules**
Connection block for NAMUR sensors and HART input/output module
- Direct machine mounting Protected fitting space (connection block to IP65) (connection block to IP20) • M12-4POL • Screw terminal • Spring-loaded terminal
Digital electronics module for inputs/outputs
- Digital electronics module for inputs/outputs a Page 145 Digital inputs Digital outputs Multi I/O modules • 4 digital inputs • 4 digital outputs (1 A per channel, • 8 digital inputs and 8 digital out• 8 digital inputs NPN individual channel diagnostics) puts
- 4 SG fc D • 8 digital inputs PNP • 8 digital outputs (0.5 A per channel, • 2 digital inputs (counter channels, • 8 digital inputs PNP with individual individual channel diagnostics) connection to various encoders) and channel diagnostics • 8 digital outputs (2.1 A/50 W lamp 2 digital outputs (directly controlled
- See • 16 digital inputs load per channel pair, individual by the input values) • 16 digital inputs with individual channel diagnostics) channel diagnostics
- Digital electronics module for NAMUR sensors a Page 150 Digital inputs • 8 digital inputs for NAMUR sensors
- h ph > or wired mechanical contacts <a Analogue electronics module for inputs/outputs a Page 186 Analogue inputs Analogue temperature inputs Analogue outputs • 2 analogue inputs (0 ... 10 V DC, • 4 analogue inputs for temperature • 2 analogue outputs (0 ... 10 V DC, 0 ... 20 mA, 4 ... 20 mA) measurement (Pt100, Pt200, 0 ... 20 mA, 4 ... 20 mA)
- • 4 analogue inputs (1 ... 5 V, Pt500, Pt1000, Ni100, Ni120, • 4 analogue outputs with HART pro-
- eo 0 ... 10 V, –5 ... +5 V, –10 ... +10 V, Ni500, Ni1000) tocol 0 ... 20 mA, 4 ... 20 mA, • 4 analogue inputs for temperature –20 ... +20 mA) measurement (thermocouple and
- • 4 analogue inputs with HART protoPT1000 sensor for cold-junction col compensation)
- PROFIsafe input module a Page 154 PROFIsafe shut-off module a Page 205 Digital inputs Digital outputs
- Soo • 8 digital inputs pense fe • 2 digital outputs • 11 function modes • Supply voltage for valves can be • 5 independent clock outputs shut off
Subject to change – 2023/10
16
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Peripherals overview
## **Individual overview of modules**
Analogue electronics module for pressure inputs
a Page 191
## Analogue inputs
- 4 analogue pressure inputs (0 ... 10 bar, –1 ... +1 bar)
Plastic interlinking block – Interlinking using tie rods
## System linking
- Different voltages for supplying the modules
- Serial communication between the modules
- System supply
- M18, 4-pin
- 7/8" 4-pin or 5-pin
Metal interlinking block – Individual linking
## System linking
- Different voltages for supplying the modules
- Serial communication between the modules
System supply
- 7/8" 4-pin or 5-pin
- M12x1, L-coded, 5-pin
- AIDA push-pull
## a Page 214
In addition to system linking, power supply for the
Power supply for the
- Valves (16 A per supply)
- Electronics plus sensors (16 A)
- Valves plus actuators (16 A)
Expandability
- Can be expanded using an interlinking block with tie rod CPX-ZA-1-E
- a Page 215
## Additional supply
In addition to system linking, power supply for the
- Actuators (16 A per supply)
In addition to system linking, power Power supply for the supply for the
- Valves (16 A per supply)
- Electronics plus sensors (16 A)
- Valves plus actuators (16 A)
## System forwarding
In addition to system linking, transmission of power supply from the
## Additional supply
- Electronics plus sensors (16 A)
In addition to system linking, power supply for the
- Valves plus actuators (16 A) to a further CPX terminal or another consuming device.
- Actuators (16 A per supply)
## Expandability
- Can be expanded as required by up to 10 interlinking blocks
## - **Note** - **Note** H- H-
Plastic interlinking blocks (tie rods) and metal interlinking blocks (individual linked) cannot be combined due to their different interlinking systems.
The 7/8" supply is subject to the following restrictions due to the available accessories:
- 5-pin 8 A • 4-pin 10 A
## - **Note** H-
Appropriate interlinking blocks (CPX-...-VL) must be used in ATEX environments as per the certification ( a page 49). The maximum supply is limited to 8 A for these modules.
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
17
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Peripherals overview
## **Individual overview of modules**
Pneumatic interface MPA-S a Page 231 Valve terminal
- MPA1 (360 l/min)
- MPA14 (550 l/min)
- MPA2 (700 l/min)
- Up to 128 solenoid coils
- Up to 16 modules can be configured
- For CPX plastic design
- For CPX metal design
- Actuation of pressure sensors
- Pneumatic interface MPA-L a Page 234 Valve terminal • MPA1 (360 l/min)
**==> picture [103 x 93] intentionally omitted <==**
- MPA14 (670 l/min)
- MPA2 (870 l/min)
- Up to 32 solenoid coils • For CPX plastic design
- Proportional pressure regulators
- Pressure sensors
- Proportional pressure regulators
## Pneumatic interface VTSA/VTSA-F
**==> picture [117 x 127] intentionally omitted <==**
a Page 236 Valve terminal (valve flow rate according to width)
- 18 mm (700 l/min)
- 26 mm (1350 l/min)
- 42 mm (1300 l/min)
- 52 mm (2900 l/min)
- 65 mm (4000 l/min)
- Max. 32 valve positions/max. 32 solenoid coils
- For CPX plastic design
- For CPX metal design
## Pneumatic interface VTSA-F-CB
**==> picture [117 x 127] intentionally omitted <==**
## a Page 238
Valve terminal (valve flow rate according to width)
- 18 mm (700 l/min)
- 26 mm (1350 l/min)
- 42 mm (1300 l/min)
- 52 mm (2900 l/min)
- Max. 24 valve positions/max. 24 solenoid coils
- For CPX plastic design
- For CPX metal design
## Pneumatic interface VTSA-F-CB
**==> picture [117 x 147] intentionally omitted <==**
## a Page 238
Valve terminal (valve flow rate according to width)
- 18 mm (700 l/min)
- 26 mm (1350 l/min)
- 42 mm (1300 l/min)
- 52 mm (2900 l/min)
- Max. 24 valve positions/max. 24 solenoid coils
- For CPX metal design
- With 3 voltage zones within the valve terminal that can be securely shut down via fieldbus
• With 2 voltage zones within the valve terminal that can be securely shut down via fieldbus and one power supply for external consuming devices that can be securely shut down via fieldbus
## Pneumatic interface VTSA-F-CB
**==> picture [117 x 127] intentionally omitted <==**
## a Page 238
Valve terminal (valve flow rate according to width)
- 18 mm (700 l/min)
- 26 mm (1350 l/min)
- 42 mm (1300 l/min)
- 52 mm (2900 l/min)
- Max. 24 valve positions/max. 24 solenoid coils
- For CPX plastic design
- For CPX metal design
- 3 external voltage supplies for voltage zones within the valve terminal that can be shut down individually
Subject to change – 2023/10
18
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Peripherals overview
## **Individual overview of modules**
End plate for plastic/metal design
End plate with extension
**==> picture [31 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
End plate<br>**----- End of picture text -----**<br>
- Left-hand
- Right-hand (for using the CPX terminal without valves)
## a Page 212
## End plate
- Left-hand
- Right-hand
- Enables the CPX terminal to be separated into two interconnected units (series)
- Simplifies control cabinet installation
End plate with system supply
a Page 210 End plate
- Left-hand
- For plastic design
- Different voltages for supplying the CPX terminal
Earthing plate (for end plate for plastic design)
## Earthing plate
- For safe and easy connection to the machine bed or H-rail, suitable for right-hand and left-hand end plate
- Assembly and earthing in a single processing step, which means:
- 50% time saving
- No additional material required
- For plastic or metal design
## **General basic data and guidelines**
Max. 11 modules in total:
- Address capacity max. 512 inputs and 512 outputs, depending on bus node or control block
- One bus node and/or one control block, freely positionable
- Up to 9 additional input/output • One interlinking block with system modules, supply freely positionable • Multiple interlinking blocks with ad-
- • An additional pneumatic interface ditional supplies always positioned as the last modAlways positioned to the right of the ule on the right-hand side interlinking block with system sup– For VTSA, VTSA-F: ply
- With just a few exceptions, the connection blocks can be freely combined with the electronics modules for inputs/outputs, either in metal or plastic design ( a table below)
- Fixed operating range, set using DIL switch
- For VTSA-F-CB: Fixed operating range
- For MPA-S:
- 16 MPA modules can be configured
- The electronics modules for inputs/ outputs can be combined with various interlinking blocks
- For MPA-L:
Fixed operating range, set using rotary switch
- Plastic interlinking blocks (tie rods) and metal interlinking blocks (individual linked) cannot be combined due to their different interlinking systems.
2023/10 – Subject to change
19
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Peripherals overview
## **Combinations of connection blocks and digital input modules**
**==> picture [524 x 210] intentionally omitted <==**
**----- Start of picture text -----**<br>
Digital electronics modules<br>CPX-4DE CPX-8DE CPX-8DE-D CPX-8NDE CPX-P-8DE-N CPX-F8DE-P<br>Connection blocks, plastic design<br>CPX-AB-8-M8-3POL h h h h – –<br>CPX-AB-8-M8X2-4POL – – – – – –<br>CPX-P-AB-4XM12-4POL – – – – h –<br>CPX-AB-4-M12x2-5POL h h h h – –<br>CPX-AB-4-M12x2-5POL-R h h h h – –<br>CPX-AB-8-M12X2-5POL – – – – – –<br>CPX-AB-4-M12-8POL – – – – – –<br>CPX-AB-8-KL-4POL h h h h – h<br>CPX-P-AB-2XKL-8POL – – – – h –<br>CPX-AB-1-SUB-BU-25POL h h h h – –<br>CPX-AB-ID-P – – – – – h<br>Connection blocks, metal design<br>CPX-M-AB-4-M12X2-5POL h h h h – h<br>CPX-M-AB-4-M12X2-5POL-T – – – – – h<br>CPX-M-AB-8-M12X2-5POL – – – – – –<br>**----- End of picture text -----**<br>
## **Combinations of connection blocks and digital input modules**
**==> picture [524 x 206] intentionally omitted <==**
**----- Start of picture text -----**<br>
Digital electronics modules<br>CPX-16DE CPX-L-16DE CPX-M-16DE-D<br>Connection blocks, plastic design<br>CPX-AB-8-M8-3POL – – –<br>CPX-AB-8-M8X2-4POL h – –<br>CPX-P-AB-4XM12-4POL – – –<br>CPX-AB-4-M12x2-5POL – – –<br>CPX-AB-4-M12x2-5POL-R – – –<br>CPX-AB-8-M12X2-5POL – – h<br>CPX-AB-4-M12-8POL – – –<br>CPX-AB-8-KL-4POL h – –<br>CPX-P-AB-2XKL-8POL – – –<br>CPX-AB-1-SUB-BU-25POL h – –<br>CPX-AB-ID-P – – –<br>Connection blocks, metal design<br>CPX-M-AB-4-M12X2-5POL – – –<br>CPX-M-AB-4-M12X2-5POL-T – – –<br>CPX-M-AB-8-M12X2-5POL – – h<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
20
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Peripherals overview
## **Combinations of connection blocks and digital output modules or multi I/O modules**
**==> picture [523 x 209] intentionally omitted <==**
**----- Start of picture text -----**<br>
Digital electronics modules<br>CPX-4DA CPX-8DA CPX-8DA-H CPX-8DE-8DA CPX-L-8DE-8DA CPX-2ZE2DA CPX-FVDA-P2<br>Connection blocks, plastic design<br>CPX-AB-8-M8-3POL h h – – – – –<br>CPX-AB-8-M8X2-4POL h h h – – – –<br>CPX-P-AB-4XM12-4POL – – – – – – –<br>CPX-AB-4-M12x2-5POL h h – – – – –<br>CPX-AB-4-M12x2-5POL-R h h h – – – –<br>CPX-AB-8-M12X2-5POL – – – – – – –<br>CPX-AB-4-M12-8POL – – – h – – –<br>CPX-AB-8-KL-4POL h h h h – – h<br>CPX-P-AB-2XKL-8POL – – – – – – –<br>CPX-AB-1-SUB-BU-25POL h h h h – – –<br>CPX-AB-ID-P – – – – – – –<br>Connection blocks, metal design<br>CPX-M-AB-4-M12X2-5POL h h h – – – h<br>CPX-M-AB-4-M12X2-5POL-T – – – – – – –<br>CPX-M-AB-8-M12X2-5POL – – – – – – –<br>**----- End of picture text -----**<br>
**==> picture [523 x 218] intentionally omitted <==**
**----- Start of picture text -----**<br>
Combinations of connection blocks and analogue electronics modules for inputs/outputs<br>Analogue electronics modules<br>CPX-4AE-4AA-H CPX-2AE-U-I CPX-4AE-U-I CPX-4AE-I CPX-2AA-U-I CPX-4AE-P CPX-4AE-T CPX-4AE-TC<br>Connection blocks, plastic design<br>CPX-AB-8-M8-3POL – – – – – – – –<br>CPX-AB-8-M8X2-4POL – – – – – – – –<br>CPX-P-AB-4XM12-4POL h – – – – – – –<br>CPX-AB-4-M12x2-5POL – h h h h – h h<br>CPX-AB-4-M12x2-5POL-R – h h h h – h h<br>CPX-AB-8-M12X2-5POL – – – – – – – –<br>CPX-AB-4-M12-8POL – – – – – – – –<br>CPX-AB-8-KL-4POL – h h h h – h h<br>CPX-P-AB-2XKL-8POL h – – – – – – –<br>CPX-AB-1-SUB-BU-25POL – h h h h – – –<br>CPX-AB-ID-P – – – – – – – –<br>Connection blocks, metal design<br>CPX-M-AB-4-M12X2-5POL – h h h h – h h<br>CPX-M-AB-4-M12X2-5POL-T – – – – – – – –<br>CPX-M-AB-8-M12X2-5POL – – – – – – – –<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
21
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features – Electrical components
## **Electrical connection – Connection block**
CPX-AB-8-M8-3POL with connection socket M8, 3-pin
**==> picture [172 x 149] intentionally omitted <==**
**----- Start of picture text -----**<br>
2<br>1<br>3<br>**----- End of picture text -----**<br>
- Compact for pre-assembled individual connection
- 8 sockets
- 3-pin design for connecting one channel per socket
## - **Note** H-
Festo delivers pre-assembled M8/ M12 connecting cables (NEBU modular system) on request:
- Tailored to the application
- Perfectly fitting
- Easy to install
|Combination of connection block and electrical connection technology|Combination of connection block and electrical connection technology|Combination of connection block and electrical connection technology|||
|---|---|---|---|---|
|Connection block<br>[1] CPX-AB-8-M8-3POL|Connection technology<br>Socket M8, 3-pin||Plug/connecting cable<br>[2] SEA-GS-M8|Connection technology<br>Solder lugs|
||||[2] SEA-3GS-M8-S|Screw terminals|
||||[3] NEBU-...-M8G3<br>(modular system for choice of connecting cables)|Socket, M8, 3-pin|
|||||Socket, M8, 4-pin|
|||||Socket, M12, 5-pin|
|||||Open cable end|
Subject to change – 2023/10
22
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features – Electrical components
## **Electrical connection – Connection block**
CPX-AB-8-M8X2-4POL with connection socket M8, 4-pin
**==> picture [371 x 170] intentionally omitted <==**
**----- Start of picture text -----**<br>
• Compact for pre-assembled individ-<br>ual connection<br>• 8 sockets<br>• 4-pin design for connection of<br>2 channels per socket<br>4<br>3<br>1<br>6<br>5<br>2<br>**----- End of picture text -----**<br>
- Compact for pre-assembled individual connection
**==> picture [523 x 260] intentionally omitted <==**
**----- Start of picture text -----**<br>
Combination of connection block and electrical connection technology<br>Connection block Connection Plug/connecting cable Connection technology Plug/connecting cable Connection technology<br>technology<br>[1] CPX-AB-8-M8X2-4POL Socket, M8, [2] NEBU-...-M8G4 Socket, M8, 3-pin – –<br>4-pin (modular system for choice of connecting Socket M8, 4-pin – –<br>cables) Socket, M12, 5-pin – –<br>Open cable end – –<br>[3] NEDY-L2R1-V1-M8G3-N-M8G4 1x plug M8, 4-pin [6] SEA-GS-M8 Solder lugs<br>(T-adapter) to [6] SEA-3GS-M8-S Screw terminals<br>2x socket, M8, 3-pin [5] NEBU-...-M8G3 Socket, M8, 3-pin<br>(modular system for choice of Socket, M8, 4-pin<br>connecting cables) Socket, M12, 5-pin<br>Open cable end<br>[4]NEDY-... 2x socket, M8, 3-pin – –<br>(modular system for all types of sensor/ 2x socket, M8, 4-pin – –<br>actuator distributor) 2x socket, M12, 5-pin – –<br>2x socket, type A – –<br>2x socket, type B – –<br>2x socket, type C – –<br>2x socket, plug pattern H – –<br>2x socket, plug pattern ZB – –<br>2x socket, plug pattern ZC – –<br>– –<br>2x open cable end<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
23
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Key features – Electrical components
## **Electrical connection – Connection block**
CPX-AB-4-M12x2-5POL and CPX-AB-4-M12x2-5PPOL-R with connection socket M12, 5-pin
**==> picture [242 x 217] intentionally omitted <==**
**----- Start of picture text -----**<br>
2<br>| UP<br>2 3<br>1a OS |<br>A RS 4) A E><br>1<br>4<br>5 a .e-<br>6<br>7<br>**----- End of picture text -----**<br>
- Suitable for self-assembly and sturdy with 2 channels per connection
- 4 sockets
- 5-pin design per connection
- Version ...-R with quick lock technology and metal thread for shielding
- With two channels per connection, the corresponding input signals can be easily connected via a T-adapter and conventional cables with M8 connection.
Subject to change – 2023/10
24
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features – Electrical components
**==> picture [523 x 453] intentionally omitted <==**
**----- Start of picture text -----**<br>
Combination of connection block and electrical connection technology<br>Connection block Connection Plug/connecting cable Connection technology Plug/connecting cable Connection technology<br>technology<br>[1] Socket, M12, [2] SEA-GS-7 Screw terminals – –<br>CPX-AB-4-M12x2-5POL 5-pin [2] SEA-4GS-7-2.5 Screw terminals – –<br>CPX-AB-4-M12x2-5POL-R [2] SEA-GS-9 Screw terminals – –<br>[2] SEA-M12-5GS-PG7 Screw terminals – –<br>[2] SEA-GS-11-DUO Screw terminals, for two – –<br>cables<br>[2] SEA-5GS-11-DUO Screw terminals, for two – –<br>cables<br>[3] NEBU-...-M12G5 Socket, M8, 4-pin – –<br>(modular system for choice of connecting Socket, M12, 5-pin – –<br>cables) Open cable end – –<br>[4] NEDY-... 2x socket, M8, 3-pin – –<br>(modular system for all types of sensor/ 2x socket, M8, 4-pin – –<br>actuator distributor) 2x socket, M12, 5-pin – –<br>2x socket, type A – –<br>2x socket, type B – –<br>2x socket, type C – –<br>2x socket, plug pattern H – –<br>2x socket, plug pattern ZB – –<br>2x socket, plug pattern ZC – –<br>2x open cable end – –<br>[5] NEDY-L2R1-V1-M8G3-N-M12G4 Plug M12, 4-pin [6] SEA-GS-M8 Solder lugs<br>(T-adapter) to [6] SEA-3GS-M8-S Screw terminals<br>2x socket, M8, 3-pin [7] NEBU-...-M8G3 Socket, M8, 3-pin<br>(modular system for choice of Socket, M8, 4-pin<br>connecting cables) Socket, M12, 5-pin<br>Open cable end<br>[5] NEDY-L2R1-V1-M12G5-N-M12G4 Plug M12, 4-pin [6] SEA-GS-7 Screw terminals<br>(T-adapter) to [6] SEA-4GS-7-2.5 Screw terminals<br>2x socket M12, 5-pin [6] SEA-GS-9 Screw terminals<br>[6] SEA-M12-5GS-PG7 Screw terminals<br>[6] SEA-GS-11-DUO Screw terminals, for two<br>cables<br>[6] SEA-5GS-11-DUO Screw terminals, for two<br>cables<br>[7] NEBU-...-M12G5 Socket, M8, 4-pin<br>(modular system for choice of Socket, M12, 5-pin<br>connecting cables) Open cable end<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
25
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Key features – Electrical components
## **Electrical connection – Connection block (metal design)**
CPX-M-AB-4-M12X2-5POL and CPX-M-AB-4-M12X2-5POL-T with connection socket M12, 5-pin
- Suitable for self-assembly and sturdy with 2 channels per connection
- 4 sockets
**==> picture [212 x 197] intentionally omitted <==**
**----- Start of picture text -----**<br>
2<br>x ;<br>a) ~@ 3<br>Bw’<br>4<br>2 | . “es<br>1<br>5<br>6<br>7<br>**----- End of picture text -----**<br>
- 5-pin design per connection
- With two channels per connection, the corresponding input signals can be easily connected via a T-adapter and conventional cables with M8 connection.
## CPX-M-AB-8-M12X2-5POL and CPX-AB-8-M12X2-5POL with connection socket M12, 5-pin
- Suitable for self-assembly and sturdy with 2 channels per connection
- 8 sockets
**==> picture [212 x 197] intentionally omitted <==**
**----- Start of picture text -----**<br>
2<br>2 L<br>Gal | 3<br>@ —&<br>4<br>1<br>5<br>6<br>7<br>**----- End of picture text -----**<br>
- 5-pin design per socket
- With two channels per connection, the corresponding input signals can be easily connected via a T-adapter and conventional connecting cables with M8 connection.
- **Note** H- Max. 4 T-adapters (NEDY) can be mounted on a connection block.
Subject to change – 2023/10
26
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features – Electrical components
**==> picture [523 x 454] intentionally omitted <==**
**----- Start of picture text -----**<br>
Combination of connection block and electrical connection technology<br>Connection block Connection Plug/connecting cable Connection technology Plug/connecting cable Connection technology<br>technology<br>[1] Socket, M12, [2] SEA-GS-7 Screw terminals – –<br>CPX-M-AB-4-M12X2-5POL 5-pin [2] SEA-4GS-7-2.5 Screw terminals – –<br>CPX-M-AB-4-M12X2-5POL-T [2] SEA-GS-9 Screw terminals – –<br>CPX-M-AB-8-M12X2-5POL [2] SEA-M12-5GS-PG7 Screw terminals – –<br>CPX-AB-8-M12X2-5POL [2] SEA-GS-11-DUO Screw terminals, for two – –<br>cables<br>[2] SEA-5GS-11-DUO Screw terminals, for two – –<br>cables<br>[3] NEBU-...-M12G5 Socket, M8, 4-pin – –<br>(modular system for choice of connecting Socket, M12, 5-pin – –<br>cables) Open cable end – –<br>[4] NEDY-... 2x socket, M8, 3-pin – –<br>(modular system for all types of sensor/ 2x socket, M8, 4-pin – –<br>actuator distributor) 2x socket, M12, 5-pin – –<br>2x socket, type A – –<br>2x socket, type B – –<br>2x socket, type C – –<br>2x socket, plug pattern H – –<br>2x socket, plug pattern ZB – –<br>2x socket, plug pattern ZC – –<br>2x open cable end – –<br>[5] NEDY-L2R1-V1-M8G3-N-M12G4 Plug M12, 4-pin [6] SEA-GS-M8 Solder lugs<br>(T-adapter) to [6] SEA-3GS-M8-S Screw terminals<br>2x socket, M8, 3-pin [7] NEBU-...-M8G3 Socket, M8, 3-pin<br>(modular system for choice of Socket, M8, 4-pin<br>connecting cables) Socket, M12, 5-pin<br>Open cable end<br>[5] NEDY-L2R1-V1-M12G5-N-M12G4 Plug M12, 4-pin [6] SEA-GS-7 Screw terminals<br>(T-adapter) to [6] SEA-4GS-7-2.5 Screw terminals<br>2x socket M12, 5-pin [6] SEA-GS-9 Screw terminals<br>[6] SEA-M12-5GS-PG7 Screw terminals<br>[6] SEA-GS-11-DUO Screw terminals, for two<br>cables<br>[6] SEA-5GS-11-DUO Screw terminals, for two<br>cables<br>[7] NEBU-...-M12G5 Socket, M8, 4-pin<br>(modular system for choice of Socket, M12, 5-pin<br>connecting cables) Open cable end<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
27
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features – Electrical components
**Electrical connection – Connection block with M12, 4-pin connection** CPX-P-AB-4XM12-4POL
**==> picture [363 x 132] intentionally omitted <==**
**----- Start of picture text -----**<br>
• Suitable for self-assembly and<br>sturdy<br>• 4 sockets<br>• 4-pin design per connection<br>3<br>2<br>1<br>**----- End of picture text -----**<br>
- Suitable for self-assembly and sturdy
|Combination of connection block and electrical connection technology|Combination of connection block and electrical connection technology|Combination of connection block and electrical connection technology|||
|---|---|---|---|---|
|Connection block<br>[1] CPX-P-AB-4XM12-4POL|Connection technology<br>Socket, M12, 4-pin||Plug/connecting cable<br>[2] SEA-GS-HAR-4POL|Connection technology<br>Insulation displacement connector|
||||[2] SEA-4GS-7-2.5|Screw terminal|
||||[2] SEA-GS-7|Screw terminal|
||||[2] SEA-GS-9|Screw terminal|
||||[3] NEDY-...<br>(modular system for all types of sensor/actuator<br>distributor)|2x open cable end|
**Electrical connection – Connection block with clamping connector** CPX-P-AB-2XKL-8POL
**==> picture [524 x 221] intentionally omitted <==**
**----- Start of picture text -----**<br>
• Quick connection technology for use<br>in control cabinets<br>• Spring-loaded terminals or screw<br>terminals<br>• Wire cross sections 0.2 ... 2.5 mm [2]<br>2<br>1<br>3<br>Combination of connection block and electrical connection technology<br>Connection block Connection technology Plug/connecting cable Connection technology<br>[1] CPX-P-AB-2XKL-8POL Plug, 8-pin [2] NECU-L3G8-C1 Spring-loaded terminals<br>[3] NECU-L3G8-C2 Screw terminals<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
28
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features – Electrical components
## **Electrical connection – Connection block**
CPX-AB-4-M12-8POL with connection socket M12, 8-pin
**==> picture [35 x 36] intentionally omitted <==**
**==> picture [140 x 91] intentionally omitted <==**
**----- Start of picture text -----**<br>
2<br>1<br>**----- End of picture text -----**<br>
- Connection to cylinder/valve combinations with max. 3 inputs and 2 outputs
- 4 sockets
- 8-pin design per socket
|Combination of connection block and electrical connection technology|Combination of connection block and electrical connection technology|Combination of connection block and electrical connection technology|||
|---|---|---|---|---|
|Connection block|Connection technology||Plug/connecting cable|Connection technology|
|[1] CPX-AB-4-M12-8POL|Socket, M12, 8-pin||[2] KM12-8GD8GS-2-PU (pre-assembled connecting<br>cable)|Socket, M12, 8-pin|
||||||
CPX-AB-8-KL-4POL, CPX-2ZE2DA with spring-loaded terminal connection
**==> picture [50 x 47] intentionally omitted <==**
**==> picture [196 x 101] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>2<br>**----- End of picture text -----**<br>
- Quick connection technology for use • Optional cover with fittings for IP65, in control cabinets IP67 connection
- 8 through-holes M9
- 32 spring-loaded terminals
- 4 spring-loaded terminals per chan– 1 through-hole M16 nel
- Blanking plug
- Wire cross-sections 0.05 ... 1.5 mm[2] – For I/O distributors, control desks or individual sensors/actuators
|Combination of connection block and electrical connection technology|Combination of connection block and electrical connection technology|Combination of connection block and electrical connection technology|Combination of connection block and electrical connection technology|Combination of connection block and electrical connection technology|
|---|---|---|---|---|
|Connection block<br>[1]<br>CPX-AB-8-KL-4POL<br>CPX-2ZE2DA|Connection technology<br>Spring-loaded terminals, 32-pin||Plug/connecting cable<br>[2] AK-8KL (cover)|Connection technology<br>–|
2023/10 – Subject to change
29
d **Internet: www.festo.com/catalogue/...**
**==> picture [596 x 40] intentionally omitted <==**
## Terminal CPX
## Key features – Electrical components
## **Electrical connection – Connection block**
CPX-AB-1-SUB-BU-25POL with Sub-D connection, 25-pin
- Multi-pin connection for I/O distributor or control desk
**==> picture [524 x 204] intentionally omitted <==**
**----- Start of picture text -----**<br>
Multi-pin connection for I/O distrib-<br>utor or control desk<br>• One socket<br>• 25-pin design<br>2<br>1<br>Combination of connection block and electrical connection technology<br>Connection block Connection technology Plug/connecting cable Connection technology<br>[1] CPX-AB-1-SUB-BU-25POL Sub-D socket, 25-pin [2] SD-SUB-D-ST25 Crimp contacts<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
30
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features – Mounting
## **Hood**
Description
The CPX hood CAFC is a space- and cost-saving alternative to a control cabinet.
It is designed as an extruded aluminium profile and is installed on a mounting plate.
The valve terminal (CPX with MPA-S or MPA-L) is well protected and is quick to install without the need for complex cabinet through feed for connecting cables and tubing.
## a Page 248
The rail and the two mounting brackets are mounted on a base plate. The hood is attached to the retaining rail and secured with two screws. There is also a stand-by position (latching of the hood in the open position).
The hood is locked using two side screws (which meet the requirements for a special lock in compliance with ATEX).
The CPX hood can be ordered online using the valve terminal configurator.
## Advantages of the CPX hood
- Impact protection (min. 7 J) for the modules underneath in combination with a suitable mounting plate provided by the user
- Protection against electrostatic discharge by using electrically conductive materials and the option of connecting an earth wire
- Protection against disconnection of live plugs (by securing the hood with at least one special fastener to EN 60079-0, 9.2 and 20)
- UV protection for the CPX and MPA modules underneath
- **Note** H- The CPX hood has no influence on the ATEX classification of the valve terminal or of the CPX terminal.
## Points to note when using the CPX hood
- Only in combination with valve ter• No MPA vertical stacking minal MPA-S and MPA-L • Use of larger fittings (for tubing O.D.
- • No bus nodes with push-pull con12 mm and larger) only possible nection (CPX-M-FB45) with the angled design
- • CPX power supply via angled plugs, • Ducted exhaust air only with elbow no T plugs, no push-pull connector
- • Electrical supply plate/additional • The permissible ambient temperasupply only possible with angled ture range of the valve terminal is plug reduced by 5°C.
- The CPX hood has no influence on The CPX hood does not protect the IP degree of protection of the against the effects of the weather in valve terminal or of the CPX terminal. installations that are not in enclosed spaces.
2023/10 – Subject to change
31
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features – Mounting
## **Hood**
Mounting
Procedure:
**==> picture [346 x 236] intentionally omitted <==**
**----- Start of picture text -----**<br>
3<br>4<br>2<br>5<br>6<br>1<br>**----- End of picture text -----**<br>
- Assemble the rail and mounting bracket included in the mounting kit
- Attach the earthing cable
- Assemble the hood (if applicable, screw together several hood sections and attach the side covers)
- Attach and secure the hood
- [1] Side cover
- [2] Earthing cable
- [3] Hood section
- [4] Slot nut with screws, for joining the hood sections
- [5] Rail
- [6] Mounting bracket
## Technical data
Weight:
- Ambient temperature –5 ... +50°C
- RoHS-compliant
- Hood: approx. 500 g per 100 mm of length
- Mounting rail: approx. 550 g per 1000 mm of length
- Side pieces: approx. 500 g per side
## **Plug coding**
**==> picture [110 x 169] intentionally omitted <==**
The connection block CPX-P-AB-2XKL8POL and the sockets NECU-L3G8 can be matched to one another using the coding elements CPX-P-KDS-AB-2XKL.
This reduces the possibility of the
socket being plugged back into an incorrect slot after being disconnected from the CPX terminal (connection safeguard).
Subject to change – 2023/10
32
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features – Mounting
## **Extension**
Functional principle
The extension enables the CPX terminal to be separated into or configured as two interconnected units (series). The two parts are controlled by a common bus node or control block. A comprehensive CPX terminal can fit into limited installation spaces more easily as two more compact units.
Applications:
- Installation in a control cabinet on two levels, one beneath the other
- Installation in two separate control cabinets
- Installation of part of the CPX terminal inside and part outside the control cabinet
- Spatial separation of electrics and pneumatics
## Performance limits
- A maximum of 10 CPX modules can The number of CPX modules and sole• the address space made available • their address requirement be installed in the first row noid coils is also limited by: by the control block/bus node • their current consumption
- • A maximum of 8 CPX modules and a pneumatic interface can be installed in the second row
- Optimisation
- The maximum possible performance or • The control block/bus node is in• The connecting cable between the • An interlinking block with additional maximum number of modules can only stalled in the first row, on the far first and second row is max. 2 m supply for valves is situated in the be achieved if the following conditions right, on an interlinking block with long second row are observed: system supply Configuration rules
- The extension limits the power supply If the 3 m connecting cable is used, When positioning output modules in • Install an interlinking block with adfor the sensors and electronics for the the following restrictions apply: the second row, a corresponding power ditional supply for outputs in the CPX terminal as a whole as follows: • There can only be one CPX module supply in the second row is required: second row to the left of the first • First row max. 6 A in the second row output module
- Second row max. 2 A • An additional supply for valves is re• First and second row together, max. quired in order to connect a valve 6 A terminal
2023/10 – Subject to change
33
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features – Mounting
## **Extension – Permissible CPX modules**
**==> picture [524 x 295] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type First row Second row<br>Control blocks CPX-CEC Permissible, at least one control block or bus Not permissible<br>node required<br>Bus node CPX-FB Permissible, at least one control block or bus Not permissible<br>CPX-M-FB node required<br>Gateway CPX-IOT Not permissible Not permissible<br>Technology modules CPX-CP Permissible Not permissible<br>CPX-CTEL<br>CPX-CTEL-2<br>CPX-CM-HPP<br>CPX-CMAX<br>CPX-CMPX<br>CPX-CMIX<br>Input/output modules CPX Permissible Permissible<br>PROFIsafe shut-off module CPX-FVDA-P2 Not permissible Not permissible<br>Interlinking block/end plate with system supply CPX-EPL-EV-S Permissible, at least one interlinking block/end Not permissible<br>CPX-GE-EV-S plate with system supply required<br>CPX-M-GE-EV-S<br>Interlinking block with additional supply CPX-GE-EV-Z Permissible Permissible<br>CPX-M-GE-EV-Z<br>CPX-GE-EV-V<br>Interlinking block without power supply CPX-GE-EV Permissible Permissible<br>CPX-M-GE-EV<br>Interlinking block with system forwarding CPX-M-GE-EV-W Not permissible Not permissible<br>Pneumatic interface VMPA-FB Not permissible Permissible<br>VMPAL-EPL-CPX Not permissible Permissible<br>VABA-S6-1 Not permissible Permissible<br>VABA-S6-1...CB Not permissible Not permissible<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
34
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features – Mounting
## **Extension – Maximum number of CPX modules/solenoid coils**
**==> picture [523 x 326] intentionally omitted <==**
**----- Start of picture text -----**<br>
Special features of the design First row Second row<br>CPX terminal with valve terminal<br>Connecting cable 3 m 10 CPX modules Valve terminal MPA-S with:<br>• Pneumatic interface for CPX metal interlinking module<br>• Electrical supply plate VMPA-FB-SP directly after the pneumatic interface<br>• Electronics modules with galvanic isolation<br>• 128 solenoid coils (64 valve positions)<br>Valve terminal VTSA/VTSA-F with:<br>• 1 CPX module with interlinking block with additional supply for valves<br>• 32 solenoid coils (32 valve positions)<br>CPX terminal without valve terminal<br>• Control block/bus node not in position on the far right of the first row 10 CPX modules • 2 ... 5 CPX modules, depending on the control block/bus node used<br>• Control block/bus node in position on the far right of the first row 10 CPX modules • 4 ... 8 CPX modules, depending on the control block/bus node used<br>CPX terminal with valve terminal MPA-S<br>– 10 CPX modules • 2 ... 5 CPX modules and connection blocks MPA-S, depending on the control<br>block/bus node used<br>• Electrical supply plates VMPA-FB-SP 10 CPX modules • 2 ... 5 CPX modules, depending on the control block/bus node used<br>• Electronics modules with galvanic isolation • Up to 128 solenoid coils (64 valve positions)<br>• Control block/bus node in position on the far right of the first row 10 CPX modules • 4 ... 5 CPX modules and connection blocks MPA-S, depending on the control<br>• CPX-FB11 or CPX-CEC not possible block/bus node used<br>• CPX-FB13 or CPX-FB36 10 CPX modules • 8 CPX modules and connection blocks MPA-S<br>• Control block/bus node in position on the far right of the first row<br>• Interlinking block with system supply in position on the far right of the first row<br>• CPX-FB13 or CPX-FB36 10 CPX modules • 8 CPX modules and connection blocks MPA-S<br>• Control block/bus node in position on the far right of the first row<br>• Interlinking block with additional supply for valves in position on the far right<br>of the first row<br>• CPX-FB13 or CPX-FB36 10 CPX modules • 8 CPX modules and connection blocks MPA-S<br>• Control block/bus node in position on the far right of the first row<br>• Interlinking block with additional supply for valves in second row<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
35
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features – Mounting
## **Extension – Maximum number of CPX modules/solenoid coils**
**==> picture [524 x 146] intentionally omitted <==**
**----- Start of picture text -----**<br>
Special features of the design First row Second row<br>CPX terminal with valve terminal MPA-L<br>– 10 CPX modules • 2 CPX modules (at least one CPX module required)<br>• 16 solenoid coils (valve widths 10 mm and 14 mm) or 8 solenoid coils (valve<br>width 20 mm)<br>• Interlinking block with additional supply for valves in second row 10 CPX modules • 2 CPX modules (at least one CPX module required)<br>• 32 solenoid coils (32 valve positions)<br>CPX terminal with valve terminal VTSA/VTSA-F<br>– 10 CPX modules • 2 CPX modules<br>• 12 solenoid coils (valve widths 18 mm, 26 mm and 42 mm) or 6 solenoid coils<br>(valve widths 52 mm and 65 mm)<br>• Interlinking block with additional supply for valves in second row 10 CPX modules • 2 CPX modules<br>• 32 solenoid coils (32 valve positions)<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
36
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features – Mounting
## **Mounting options**
Valve terminals with CPX terminal support different mounting options for direct machine mounting with a high degree of protection and control cabinet installation.
H-rail mounting
**==> picture [86 x 141] intentionally omitted <==**
**==> picture [12 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
A<br>**----- End of picture text -----**<br>
**==> picture [12 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>**----- End of picture text -----**<br>
The H-rail mounting is part of the rear profile of the CPX interlinking blocks. The CPX terminal can be attached to the H-rail using the H-rail mounting kit. The CPX terminal is first hooked onto the H-rail (see arrow [A]),
then swivelled onto the H-rail and secured in place with the clamping element (see arrow [B]).
The optional earthing plate enables a connection to be established to the machine potential/earth in one easy step.
The following mounting kit is needed for H-rail mounting:
• CPX-CPA-BG-NRH
This facilitates mounting of the CPX terminal on H-rails to EN 60715. An additional mounting kit may be required for combination with valve terminals.
## Wall mounting
**==> picture [254 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
3 2 2<br>1 1 1<br>1<br>3<br>1 1<br>**----- End of picture text -----**<br>
The end plates of the CPX terminal, the valve terminal and the pneumatic interface include mounting holes [1] for wall mounting. Additional mountings [2] for the CPX terminal are available for longer valve terminals. These mountings differ depending on the design of the CPX terminal (plastic or metal).
In the case of 4 and more interlinking blocks, additional wall mountings must be used every 100 ...150 mm:
- Type CPX-M-BG-RW (metal design). These wall mountings are screwed in at the top on the CPX module.
- Type CPX-BG-RW (plastic design). These wall mountings are hooked in at the top and bottom between the CPX modules.
2023/10 – Subject to change
37
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Key features – Mounting
## **CPX terminal in plastic design**
Additional mountings
For longer valve terminals, there are additional mounting components for the CPX terminal that can be fitted between two modules.
## - **Note** H-
For CPX terminals with 4 or more interlinking blocks,
you need additional mounting components of type CPX-BG-RW every 100 or 150 mm. These are supplied pre-assembled.
## Interlinking with tie rods
**==> picture [132 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>2<br>Nea [SO] 3<br>**----- End of picture text -----**<br>
The mechanical connection between the CPX modules is created using special tie rods [2]. The entire unit can be assembled using two screws in the end plates.
The tie rod ensures that the unit has a high mechanical load-bearing capacity and is therefore the mechanical “backbone” of the CPX terminal.
The open design allows interlinking blocks [1] to be replaced when already mounted.
With the tie rod extension kit [3] an extra module can be added to the CPX terminal.
## **CPX terminal in metal design**
Additional mountings
For longer valve terminals, there are additional mounting brackets for the CPX terminal that can be screwed onto the interlinking blocks.
The mounting bracket CPX-M-BG-VT-2X enables a CPX terminal with valve terminal VTSA/VTSA-F/VTSA-F-CB to be mounted on a support system.
## - **Note** H-
In the case of CPX terminals with 4 or more interlinking blocks, additional mounting brackets of the type CPX-MBG-RW must be used every 100 or 150 mm. These are supplied pre-assembled.
Linking with screws
The CPX modules are mechanically connected using an angled fitting. The CPX terminal can thus be expanded at any time.
Subject to change – 2023/10
38
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features – Power supply
## **Power supply concept**
General
**==> picture [487 x 162] intentionally omitted <==**
**==> picture [243 x 94] intentionally omitted <==**
**==> picture [428 x 123] intentionally omitted <==**
The use of decentralised devices on the fieldbus – particularly with a high degree of protection for direct machine mounting – demands a flexible power supply concept.
A valve terminal with CPX is, in principle, supplied with all voltages via a single connection.
A distinction is made between the supSelectable connection technology: ply for • M18
- 7/8“
- Electronics plus sensors
- Valves plus actuators in this case.
- M12x1
• AIDA push-pull
## Interlinking blocks
Interlinking blocks represent the backbone of the CPX terminal with all supply lines. They provide the power supply for the modules used on them as well as their bus connections.
Many applications require the CPX terminal to be separated into voltage zones. This applies in particular to the separate disconnection of solenoid coils and outputs.
The interlinking blocks provide either an easy-to-install central power supply for the entire CPX terminal or galvanically isolated, all-pin disconnectable potential groups/voltage segments.
2023/10 – Subject to change
39
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Key features – Power supply
## **Interlinking blocks**
With system supply
Plastic design
- CPX-GE-EV-S
- CPX-GE-EV-S-7/8-4POL
- CPX-GE-EV-S-7/8-5POL
Metal design
- CPX-M-GE-EV-S-7/8-CIP-4P
- CPX-M-GE-EV-S-7/8-5POL
- CPX-M-GE-EV-S-M12-5POL
- CPX-M-GE-EV-S-PP-5POL
## Connection technology
- M18, 4-pin
- 7/8" 4-pin
- 7/8" 5-pin
Connection technology
- 7/8" 4-pin
- 7/8" 5-pin
- M12x1, L-coded, 5-pin
- AIDA push-pull, 5-pin
Power supply
- For CPX terminal modules and connected sensors
- For valves that are connected to the CPX terminal via a pneumatic interface
- For actuators that are connected to the output modules of the CPX terminal
Without power supply
Plastic design
–
–
- CPX-GE-EV
Metal design
- CPX-M-GE-EV –
• CPX-M-GE-EV-FVO
With additional supply for outputs
Plastic design Connection technology
- M18, 4-pin
- CPX-GE-EV-Z
- CPX-GE-EV-Z-7/8-4POL • 7/8" 4-pin • CPX-GE-EV-Z-7/8-5POL • 7/8" 5-pin Metal design Connection technology
Power supply
- For actuators that are connected to output modules of the CPX terminal
- CPX-M-GE-EV-Z-7/8-5POL • 7/8" 5-pin
- CPX-M-GE-EV-Z-PP-5POL
- AIDA push-pull, 5-pin
With additional supply for valves
- **Note** H- For 7/8":
- Commercially available accessories are often limited to max. 8 A
Plastic design
- CPX-GE-EV-V
- CPX-GE-EV-V-7/8-4POL
## - **Note** H-
The valve terminal MPA-S has either a 7/8" 5-pin, 7/8" 4-pin, 3-pin M18 or 5-pin AIDA push-pull power supply for one or more valve voltage zones. Galvanically isolated, all-pin disconnectable with voltage monitoring in the following MPA module.
## Connection technology
- M18, 4-pin
- 7/8" 4-pin
## - **Note** H-
Suitable versions of the interlinking blocks with M18 and 7/8", 5-pin connection are available (CPX-GE-EV...-VL and CPX-M-GE-EV-...-VL) for use in ATEX environments as per certification ( a page 49). The maximum current supply for these interlinking blocks is 8 A.
Power supply
- For valves that are connected to the CPX terminal via a pneumatic interface
Subject to change – 2023/10
40
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features – Power supply
## **Interlinking blocks**
With system forwarding
**==> picture [49 x 120] intentionally omitted <==**
- Metal design Connection technology • CPX-M-GE-EV-W-M12-5POL • M12x1, L-coded, 5-pin
Voltage transmission
- For a further CPX terminal
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
41
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features – Diagnostics
## **Diagnostics**
System performance
**==> picture [257 x 112] intentionally omitted <==**
**----- Start of picture text -----**<br>
3 4 5<br>1<br>2 6<br>**----- End of picture text -----**<br>
Detailed diagnostic functions are The CPX terminal supports on-the-spot needed in order to quickly locate the diagnostics via a row of LEDs. This is causes of errors in the electrical instalseparate from the connection area and lation and therefore reduce downtimes therefore provides good visual access in production plants. to status and diagnostic information. A basic distinction is made between on-the-spot diagnostics using LEDs or a diagnostic interface and diagnostics using a bus interface.
- [1] Diagnostics via bus interface
- [2] Undervoltage monitoring
- [3] Diagnostic overview LED – Fieldbus status
- CPX status
- [4] Status and diagnostic LED for module and I/O channels
- [5] Module and channel-specific diagnostics
Module and channel-specific diagnostics are supported, for example:
- Undervoltage detection for outputs and valves
- Short circuit detection for sensors, outputs and valves
- Open-load detection for a missing solenoid coil
- Storage of the last 40 causes of errors with error start and error end
- [6] Valve-specific diagnostic module and solenoid coils
- [7] MPA pressure sensor – integrated solution on the fieldbus
- Pre-assembled for channels 1, 3, 5 and external pressures
The diagnostic messages can be read out via the bus interface in the higher-order controller and visualised for the central recording and evaluation of error causes. This is done using the individual fieldbus-specific channels. CPX-CECs also offer the option of access via the integrated Ethernet interface (remote maintenance via PC/web applications).
Overview of LEDs on the bus node ~~1~~ [1] Fieldbus-specific LEDs [2] CPX-specific LEDs On each bus node, a maximum of 4 A further 4 CPX-specific LEDs provide fieldbus-specific LEDs display the fieldnon-fieldbus-specific information 2 bus communication status of the CPX about the status of the CPX terminal, terminal with the higher-order for example: controller. – Power system – Power load – System fault – Modify parameters Input/output module status and diagnostic LEDs
|||||~~1~~|||~~2~~|~~2~~|||~~3~~||[1] Status LEDs for the inputs and|[2] Channel-oriented diagnostic LEDs|[3] Group diagnostic LEDs|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||||||||||outputs|Depending on the module design, an-|An LED displays the group diagnostics|
||||||||||||||Each input and output channel is as-|other diagnostic LED is available for|for each module|
|||**0**|**4**|||**0**<br>**4**|||||||signed a status LED.|each I/O channel||
||**1**<br>**2**<br>**3**<br>**8**<br>**DI**||**5**<br>**6**<br>**7**|||**1**<br>**2**<br>**3**<br>**5**<br>**6**<br>**7**|||||**8**<br>**DO**|||||
|||||||||||||||||
Subject to change – 2023/10
42
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Key features – Diagnostics
**==> picture [384 x 133] intentionally omitted <==**
**----- Start of picture text -----**<br>
Diagnostics<br>Display on a PC<br>[1] CPX terminal with valve terminal<br>3 [2] Adapter diagnostic interface to<br>USB<br>[3] Laptop/portable device with USB<br>2<br>interface and installed FMT<br>software<br>– Fault location and type<br>1 eARWR » – Without programming<br>– Storing the configuration<br>**----- End of picture text -----**<br>
- Preparing screenshots
**==> picture [85 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Data gathering via gateway<br>**----- End of picture text -----**<br>
**==> picture [455 x 240] intentionally omitted <==**
**----- Start of picture text -----**<br>
5<br>7<br>9<br>1<br>a CS 4<br>3<br>8 10<br>6<br>L A 3 SS<br>3<br>PS a<br>2<br>se i ne Ol a l<br>*s Se | |e oe le I a ><br>> J lL Pea<br>ZB ° e y<br>ne Oh age aa<br>4<br>**----- End of picture text -----**<br>
- [1] PLC to machine/system controller [3] Festo components with bus con(no direct internet connection) nection with serial linking
- [6] Internet connection
- [7] Customer firewall or other security precautions
- [2] Bus system from the controller to [4] Components from which the CPXprecautions the system parts (e.g. PROFINET) IOT is collecting and transferring [8] Transferring data to a central data storage location (MQTT broker)
- [5] Gateway CPX-IOT using secure protocols
- [9] Central storage location (user-specific MQTT broker) provided by Festo
- [10] Simple decentralised evaluation of data using adapted programs (apps) for the components that are being monitored
2023/10 – Subject to change
43
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features – Parameterisation
## **Parameterisation**
Changes to the application are often required during commissioning. The parameterisable characteristics of the CPX modules mean that functions can be very easily changed using configuration software. This reduces the number of modules needed and, consequently, the amount of storage space required.
It is therefore possible, for example, to reduce the input debounce time for an input module – normally 3 ms – to 0.1 ms on a "fast" input module for faster processes, or to set the response of a valve following a fieldbus interruption.
Depending on the modules used, parameterisation can be carried out via the following interfaces:
- Ethernet
- Fieldbus
- Control block direct interface (programming interface)
**==> picture [230 x 119] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>2<br>**----- End of picture text -----**<br>
- [1] Input debounce time 3 ms
- [2] Input debounce time 0.1 ms
Subject to change – 2023/10
d **Internet: www.festo.com/catalogue/...**
44
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features – Addressing
## **Addressing**
The various CPX modules occupy a different number of I/O addresses within the CPX system. The maximum address space for bus nodes depends on the performance of the fieldbus systems.
Maximum system configuration:
- 1 bus node or control block
- 9 I/O modules
• 1 pneumatic interface (e.g. pneumatic interface MPA-S with up to 16 MPA connection blocks)
The maximum system configuration - **Note** can be limited in individual cases by H- exceeding the address space. Please refer to the detailed description of the configuration/addressing rules in the technical data for CPX bus nodes.
## **Overview – Address space for CPX bus node and control block**
**==> picture [523 x 185] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protocol Max. total Max. digital Max. analogue<br>Inputs Outputs Inputs Outputs Inputs Outputs<br>CPX-CEC • CODESYS Level 2 512 bits 512 bits 512 DI 512 DO 32 AI 18 AO<br>• TCP/IP<br>• Easy IP<br>• Modbus TCP<br>CPX-FB11 DeviceNet 512 bits 512 bits 512 DI 512 DO 32 AI 18 AO<br>CPX-FB13 PROFIBUS 512 bits 512 bits 512 DI 512 DO 32 AI 18 AO<br>CPX-FB14 CANopen 256 bits 256 bits 64 DI (+ 64 DI) 64 DO (+ 64 DO) 8 AI (+ 8 AI) 8 AO (+ 8 AO)<br>CPX-FB23-24 CC-Link 512 bits 512 bits 512 DI 512 DO 32 AI 18 AO<br>CPX-FB36 EtherNet/IP 512 bits 512 bits 512 DI 512 DO 32 AI 18 AO<br>CPX-FB37 EtherCAT 512 bits 512 bits 512 DI 512 DO 32 AI 18 AO<br>CPX-FB39 Sercos III 512 bits 512 bits 512 DI 512 DO 32 AI 18 AO<br>CPX-FB40 POWERLINK 512 bits 512 bits 512 DI 512 DO 32 AI 18 AO<br>CPX-FB43 PROFINET RT 512 bits 512 bits 512 DI 512 DO 32 AI 18 AO<br>CPX-M-FB44 PROFINET RT 512 bits 512 bits 512 DI 512 DO 32 AI 18 AO<br>CPX-M-FB45 PROFINET RT 512 bits 512 bits 512 DI 512 DO 32 AI 18 AO<br>**----- End of picture text -----**<br>
## - **Note** H-
The bandwidth of the bus nodes can be restricted by the choice of module and the maximum number of modules.
## **Example – CPX-FB43 (PROFINET RT)**
**==> picture [523 x 71] intentionally omitted <==**
**----- Start of picture text -----**<br>
Digital inputs Digital outputs Remarks<br>1x CPX-CM-HPP 256 256 • The address space is occupied by 7 CPX I/O modules<br>2x CPX-2ZE2DA 192 192 plus pneumatic interface<br>4x CPX-16DE 64 – • No additional modules can be configured<br>8x VMPA1 – 64<br>Allocated address space 512 512<br>**----- End of picture text -----**<br>
DI = Digital inputs (1 bit) DO = Digital outputs (1 bit) AO = Analogue outputs (16 bits) AI = Analogue inputs (16 bits)
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
45
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Key features – Addressing
## **Overview – Allocated addresses for CPX modules**
**==> picture [524 x 607] intentionally omitted <==**
**----- Start of picture text -----**<br>
Inputs [bit] Outputs [bit]<br>CPX-CP-4-FB 16, 32, 48, 64, 80, 96, 128 [1)] 16, 32, 48, 64, 80, 96, 128 [1)]<br>CPX-CTEL-4-M12-5POL 0, 64, 128, 192, 256 [1)] 0, 64, 128, 192, 256 [1)]<br>CPX-CTEL-2-M12-5POL-LK 64, 128, 192, 256 [1)] 64, 128, 192, 256 [1)]<br>CPX-CM-HPP 256 256<br>CPX-CMAX-C1-1 64 64<br>CPX-CMPX-C-1-H1 48 48<br>CPX-CMIX-M1-1 48 48<br>CPX-4DE 4 –<br>CPX-8DE 8 –<br>CPX-8DE-D 8 –<br>CPX-8NDE 8 –<br>CPX-P-8DE-N 16 8<br>CPX-P-8DE-N 80 16<br>(inputs configured as counter)<br>CPX-F8DE-P 48 56<br>CPX-16DE 16 –<br>CPX-M-16DE-D 16 –<br>CPX-L-16DE-16-KL-3POL 16 –<br>CPX-4DA – 4<br>CPX-8DA – 8<br>CPX-8DA-H – 8<br>CPX-8DE-8DA 8 8<br>CPX-L-8DE-8DA-16-KL-3POL 8 8<br>CPX-2ZE2DA 96 96<br>CPX-4AE-4AA-H 0, 16, 32, 48, 64, 128, 144, 160, 176, 192 [1)] 0, 16, 32, 48, 64 [1)]<br>CPX-2AE-U-I 2 x 16 –<br>CPX-4AE-U-I 4 x 16 –<br>CPX-4AE-I 4 x 16 –<br>CPX-4AE-P-B2 4 x 16 –<br>CPX-4AE-P-D10 4 x 16 –<br>CPX-4AE-T 4 x 16 –<br>CPX-4AE-TC 4 x 16 –<br>CPX-2AA-U-I – 2 x 16<br>CPX-FVDA-P2 48 48<br>VMPA1-FB-EMS-8 – 8<br>VMPA1-FB-EMG-8 – 8<br>VMPA2-FB-EMS-4 – 4<br>VMPA2-FB-EMG-4 – 4<br>VMPA1-FB-EMS-D2-8 – 8<br>VMPA1-FB-EMG-D2-8 – 8<br>VMPA2-FB-EMS-D2-4 – 4<br>VMPA2-FB-EMG-D2-4 – 4<br>VMPA-FB-PS-1 16 –<br>VMPA-FB-PS-3/5 16 –<br>VMPA-FB-PS-P1 16 –<br>VMPA-FB-EMG-P1 16 16<br>VMPAL-EPL-CPX – 4, 8, 16, 24, 32 [1)]<br>VABA-S6-1-X1 – 8, 16, 24, 32 [1)]<br>VABA-S6-1-X2 – 8, 16, 24, 32 [1)]<br>VABA-S6-1-X2-D 8, 16, 24, 32 [1)] 8, 16, 24, 32 [1)]<br>VABA-S6-1-X1-CB – 8, 16, 24 [1)]<br>VABA-S6-1-X2-CB – 8, 16, 24 [1)]<br>VABA-S6-1-X2-F1-CB – 8, 16, 24 [1)]<br>VABA-S6-1-X2-F2-CB – 8, 16, 24 [1)]<br>VABA-S6-1-X1-3V-CB – 8, 16, 24 [1)]<br>VABA-S6-1-X2-3V-CB – 8, 16, 24 [1)]<br>**----- End of picture text -----**<br>
- 1) Dependent on the DIL switch setting on the module
Subject to change – 2023/10
46
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet
-KModule width 50 mm
## **Example**
## - **Note** H-
The data given here apply to the CPX system. If components that conform to lower values are used in the system, the specification for the entire system is reduced to the values for those components.
Degree of protection IP65/IP67 applies only to the fully assembled system with fitted plugs or covers (which must also conform to IP65/IP67).
If components with a lower degree of protection are used, the protection level of the entire system is reduced to the degree of protection of the component with the lowest degree of protection, for example CageClamp connection block with degree of protection IP20 or MPA pneumatics with degree of protection IP65.
## **General technical data**
|to lower values are used in the sys-<br>tem, the specification for the entire<br>system is reduced to the values for<br>those components.<br>nent with the lowest degree of protec-<br>tion, for example CageClamp connec-<br>tion block with degree of protection<br>IP20 or MPA pneumatics with degree of<br>protection IP65.|to lower values are used in the sys-<br>tem, the specification for the entire<br>system is reduced to the values for<br>those components.<br>nent with the lowest degree of protec-<br>tion, for example CageClamp connec-<br>tion block with degree of protection<br>IP20 or MPA pneumatics with degree of<br>protection IP65.|
|---|---|
|**General technical data**<br>Module no.<br>197330<br>Max. number of modules1)<br>Control block<br>1<br>Bus node<br>1<br>I/O modules/CP interface/CTEL interface/electri-<br>cal interface CPX-CTEL-2/multi-axis interface<br>9<br>Pneumatic interface<br>1||
||1|
||9|
||1|
|Max. address capacity<br>Inputs<br>[byte]<br>Outputs<br>[byte]|64|
||64|
|Internal cycle time<br>[ms]|<1|
|Configuration support|Fieldbus-specific|
|LED displays<br>Bus node/control block/gateway<br>I/O modules<br>Pneumatic interface|Up to 4 LEDs, bus-specific<br>4 LEDs, CPX-specific<br>• PS = Power system<br>• PL = Power load<br>• SF = System fault<br>• M = Modify parameter/forcingactive|
||Min. one centralised diagnostic LED<br>Channel-oriented status and diagnostic LED, dependingon module|
||One centralised diagnostic LED<br>Valve status LED on valve|
|Diagnostics|• Channel and module-oriented diagnostics for inputs/outputs and valves<br>• Detection of module undervoltage for the different potential values<br>• Storage of the last 40 errors with timestamp (acyclic access)|
1) A maximum of 11 modules in total can be combined (e.g. 1 control block + 9 I/O modules + 1 pneumatic interface, or 1 control block + 1 bus node + 8 I/O modules + 1 pneumatic interface)
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
47
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet
## **General technical data**
**==> picture [524 x 441] intentionally omitted <==**
**----- Start of picture text -----**<br>
Module no. 197330<br>Parameterisation Module-specific and entire system, for example:<br>• Diagnostic behaviour<br>• Condition monitoring<br>• Profile of inputs<br>• Fail-safe response of outputs and valves<br>Commissioning support Forcing of inputs and outputs<br>Degree of protection to EN 60529 IP65, IP67<br>Nominal operating voltage [V DC] 24<br>Operating voltage range [V DC] 18 ... 30<br>Power supply Interlinking block with system supply<br>Electronics plus sensors<br>Actuators plus valves [A] 16 (8/10 with 7/8" supply, 5-pin/4-pin)<br>[A] 16 (8/10 with 7/8" supply, 5-pin/4-pin)<br>Additional supply<br>Actuators [A] 16 (8/10 with 7/8" supply, 5-pin/4-pin)<br>Additional supply for valves [A] 16 (10 with 7/8" supply, 4-pin)<br>Current consumption Depending on system configuration<br>Mains buffering (bus electronics only) [ms] 10<br>Power supply connection M18, 4-pin<br>7/8" 5-pin<br>7/8" 4-pin<br>AIDA push-pull, 5-pin<br>Fuse concept Per module with electronic fuses<br>Tests Vibration test to DIN IEC 68 • With wall mounting: Severity level 2<br>• With H-rail mounting: Severity level 1<br>Shock test to DIN IEC 68 • With wall mounting: Severity level 2<br>• With H-rail mounting: Severity level 1<br>PWIS conformity VDMA24364-B2-L<br>Immunity to interference EN 61000-6-2 (industry)<br>Emitted interference EN 61000-6-4 (industry)<br>Isolation test for galvanically isolated circuits to IEC 1131 Part 2 [V DC] 500<br>Galvanic isolation of electrical voltages [V DC] 80<br>Protection against direct and indirect contact PELV<br>Materials End plates: Die-cast aluminium<br>Grid dimension [mm] 50<br>Operating and environmental conditions<br>Module no. 197330<br>Ambient temperature [°C] –5 ... +50<br>Storage temperature [°C] –20 ... +70<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
48
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet
## **Certifications and approvals – Maximum values**
**==> picture [523 x 165] intentionally omitted <==**
**----- Start of picture text -----**<br>
Module no. 197330<br>ATEX category gas II 3G<br>Type of ignition protection for gas Ex nA IIC T4 X Gc<br>Explosion-proof ambient temperature [°C] –5 ≤ Ta ≤ +50<br>CE marking (see declaration of conformity) [2)] To EU Explosion Protection Directive (ATEX)<br>To EU EMC Directive [1)]<br>To EU RoHS Directive<br>UKCA marking (see declaration of conformity) [2)] To UK EX instructions<br>To UK instructions for EMC<br>To UK RoHS instructions<br>KC mark KC EMC<br>Degree of protection to EN 60529 IP65, IP67<br>Certification c UL us - Recognized (OL)<br>RCM<br>Explosion protection certification outside the EU EPL Gc (Ru)<br>**----- End of picture text -----**<br>
1) For information about the area of use, see the EC declaration of conformity at: www.festo.com/catalogue/... d Support/Downloads.
If the devices are subject to usage restrictions in residential, commercial or light-industrial environments, further measures for the reduction of the emitted interference may be necessary.
2) Additional information at: www.festo.com/catalogue/... d Support/Downloads.
## - **Note** H-
The values indicated represent the maximum performance limits that can be achieved with the fully assembled product. Depending on the individual components used, the val-
ue actually achieved for the overall product may be lower. You can select e.g. the individual components required to achieve the ATEX category by choosing the corre-
sponding features in the online product configurator: a Internet:cpx
2023/10 – Subject to change
49
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet
**==> picture [524 x 639] intentionally omitted <==**
**----- Start of picture text -----**<br>
Weights [g]<br>Control block CEC 155 CP interface CP 139<br>CEC...V3 135 CTEL interface CTEL 110<br>Bus node – – Electrical interface CTEL-2 110<br>FB11 120 Axis interface CM-HPP 140<br>FB13 115 Axis controller CMAX 140<br>FB14 115 End-position controller CMPX 140<br>– – Measuring module CMIX 140<br>FB23-24 115 Plastic connection block 8-way, M8 3-pin 62<br>– – 8-way, M8 4-pin 65<br>– – 4-way, M12 5-pin 60<br>– – 4-way, M12 5-pin, quick lock, shielded with 87<br>FB36 125 metal thread<br>FB37 125 8-way, M12 5-pin 76<br>FB39 125 4-way, M12 8-pin 65<br>FB40 125 Spring-loaded terminal, 32-pin 75<br>FB43 185 Sub-D 25-pin 72<br>FB44 280 8-way, DIL switch 57<br>FB45 280<br>Gateway IOT 130 Connection block for NAMUR 4-way, M12 4-pin 120<br>I/O module 4 digital outputs 42 and HART module Clamping connector 8-pin 100<br>4 digital inputs 39 Metal connection block 4-way, M12 5-pin 112<br>8 digital inputs 39 4-way, M12 5-pin, pulsed sensor supply 110<br>8 digital inputs, positive logic (PNP), 45 8-way, M12 5-pin 152<br>enhanced diagnostic function<br>8 digital inputs, negative logic (NPN) 40 Plastic interlinking block Without power supply 108<br>System supply 125<br>8 digital inputs to NAMUR 100 Interlinking block, metal Without power supply 169<br>16 digital inputs, internal electronic fuse per 41 System supply, 7/8" 4-pin 228<br>module System supply, 7/8" 5-pin 187<br>16 digital inputs, internal electronic fuse per 46 System supply, M12x1 279<br>channel pair, for CPX in metal System supply, push-pull 279<br>System forwarding, M12x1 279<br>16 digital inputs, for CPX in plastic, including 167 Tie rods 1-way 41<br>interlinking block and connection block with 2-way 71<br>spring-loaded terminals 3-way 97<br>4-way 127<br>8 digital inputs, 8 digital outputs 48 5-way 156<br>8 digital inputs, 8 digital outputs, for CPX in 171 6-way 173<br>plastic, including interlinking block and con- 7-way 199<br>nection block with spring-loaded terminals 8-way 247<br>9-way 274<br>8 digital outputs, power supply 0.5 A per 49 10-way 301<br>channel End plate for plastic design Left-hand 110<br>8 digital outputs, power supply 2.1 A per 48 Left-hand, with system supply 145<br>channel pair Right-hand 110<br>2 analogue current or voltage inputs 48 End plate for metal design Left-hand 113<br>Right-hand 113<br>4 analogue current inputs 47 End plate with extension Left-hand 190<br>2 analogue current or voltage outputs 49 Right-hand 175<br>Pneumatic interface MPA-S 238.4<br>4 analogue inputs/outputs, HART 77.4 VTSA/VTSA-F 590<br>2 or 4 analogue temperature inputs 47 VTSA-F-CB without voltage zones 560<br>4 analogue temperature inputs, with 2-wire 46 VTSA-F-CB with safe voltage zones 734<br>connection for a PT1000 sensor for cold junc- VTSA-F-CB with safe voltage zones and power 754<br>tion compensation supply for external consuming devices<br>4 analogue pressure inputs 115<br>PROFIsafe Shut-off module 50<br>Input module 46 VTSA-F-CB with external power supply 580<br>Counter module 2ZE2DA 130<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
50
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet
**==> picture [523 x 590] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data – Accessories<br>Designation Part no. Type<br>Mounting<br>Attachment for wall mounting (for long valve terminals, 10 pieces), design for plastic manifold 529040 CPX-BG-RW-10x<br>sub-bases<br>Attachment for wall mounting, version for metal 2 mounting brackets, 4 screws 550217 CPX-M-BG-RW-2X<br>manifold sub-bases 1 mounting bracket, 2 screws 2721419 CPX-M-BG-VT-2X<br>Mounting for H-rail CPX without pneumatic components 526032 CPX-CPA-BG-NRH<br>CPX-VTSA<br>CPX-VTSA-F<br>CPX-MPA<br>Tie rod<br>Tie rod CPX Extension, 1 module 525418 CPX-ZA-1-E<br>1-module 195718 CPX-ZA-1<br>2-module 195720 CPX-ZA-2<br>3-module 195722 CPX-ZA-3<br>4-module 195724 CPX-ZA-4<br>5-module 195726 CPX-ZA-5<br>6-module 195728 CPX-ZA-6<br>7-module 195730 CPX-ZA-7<br>8-module 195732 CPX-ZA-8<br>9-module 195734 CPX-ZA-9<br>10-module 195736 CPX-ZA-10<br>Plastic interlinking block<br>Without power supply – 195742 CPX-GE-EV<br>With system supply M18 195746 CPX-GE-EV-S<br>M18, for ATEX environment 8022170 CPX-GE-EV-S-VL<br>7/8" – 4-pin 541248 CPX-GE-EV-S-7/8-4POL<br>7/8" – 5-pin 541244 CPX-GE-EV-S-7/8-5POL<br>7/8" – 5-pin, for ATEX environment 8022172 CPX-GE-EV-S-7/8-5POL-VL<br>With additional supply for outputs M18 195744 CPX-GE-EV-Z<br>M18, for ATEX environment 8022166 CPX-GE-EV-Z-VL<br>7/8" – 4-pin 541250 CPX-GE-EV-Z-7/8-4POL<br>7/8" – 5-pin 541246 CPX-GE-EV-Z-7/8-5POL<br>7/8" – 5-pin, for ATEX environment 8022173 CPX-GE-EV-Z-7/8-5POL-VL<br>With additional supply for valves M18 533577 CPX-GE-EV-V<br>M18, for ATEX environment 8022171 CPX-GE-EV-V-VL<br>7/8" – 4-pin 541252 CPX-GE-EV-V-7/8-4POL<br>Interlinking block, metal<br>Without power supply – 550206 CPX-M-GE-EV<br>For CPX-FVDA-P2 only 567806 CPX-M-GE-EV-FVO<br>With system supply 7/8" – 4-pin 568956 CPX-M-GE-EV-S-7/8-CIP-4P<br>7/8" – 5-pin 550208 CPX-M-GE-EV-S-7/8-5POL<br>7/8" – 5-pin, for ATEX environment 8022165 CPX-M-GE-EV-S-7/8-5POL-VL<br>M12x1, L-coded, 5-pin 8098392 CPX-M-GE-EV-S-M12-5POL<br>Push-pull – 5-pin 563057 CPX-M-GE-EV-S-PP-5POL<br>With additional supply for outputs 7/8" – 5-pin 550210 CPX-M-GE-EV-Z-7/8-5POL<br>7/8" – 5-pin, for ATEX environment 8022158 CPX-M-GE-EV-Z-7/8-5POL-VL<br>Push-pull – 5-pin 563058 CPX-M-GE-EV-Z-PP-5POL<br>With system forwarding M12x1, L-coded, 5-pin 8098391 CPX-M-GE-EV-W-M12-5POL<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
51
Terminal CPX
## Data sheet
## **Ordering data – Accessories**
|**Ordering data – Accessories**<br>Designation<br>Part no.<br>Type<br>gaccessories<br>~~Cn~~<br>~~_———————EE~~|**Ordering data – Accessories**<br>Designation<br>Part no.<br>Type<br>gaccessories<br>~~Cn~~<br>~~_———————EE~~|**Ordering data – Accessories**<br>Designation<br>Part no.<br>Type<br>gaccessories<br>~~Cn~~<br>~~_———————EE~~|**Ordering data – Accessories**<br>Designation<br>Part no.<br>Type<br>gaccessories<br>~~Cn~~<br>~~_———————EE~~|
|---|---|---|---|
|Screws for mounting the bus node/connection block on the plas-<br>tic interlinkingblock<br>Screws for mounting the bus node/connection block on the met-<br>al interlinking block<br>~~Cn~~<br>~~_———————EE~~<br>~~ee~~|Bus node/metal connection block<br>~~Cn~~<br>~~_———————EE~~|**550218**<br>~~Cn~~<br>~~_———————EE~~<br>~~ee~~|**CPX-DPT-30X32-S-4X**<br>~~Cn~~<br>~~_———————EE~~<br>~~ee~~|
||Bus node/plastic connection block<br>~~_———————EE~~<br>~~ee~~|**550219**<br>~~_———————EE~~<br>~~ee~~<br>~~ee~~|**CPX-M-M3x22-4x**<br>~~_———————EE~~<br>~~ee~~<br>~~ee~~|
||Bus node/metal connection block<br>~~_———————EE~~<br>~~ee~~|**550216**<br>~~_———————EE~~<br>~~ee~~<br>~~ee~~|**CPX-M-M3x22-S-4x**<br>~~_———————EE~~<br>~~ee~~<br>~~ee~~|
|~~_———————EE~~<br>~~ee~~<br>~~ee~~||||
|lates forplastic design<br>~~ee~~<br>~~ee~~||||
|Left-hand end plate<br>~~SF~~|–<br>~~SF~~|**195716**<br>~~SF~~|**CPX-EPL-EV**<br>~~SF~~|
||With system supply<br>~~SF~~|**576315**<br>~~SF~~|**CPX-EPL-EV-S**<br>~~SF~~|
||With extension<br>~~SF~~<br>~~ee~~|**576314**<br>~~SF~~|**CPX-EPL-EV-X**<br>~~SF~~<br>~~ee~~|
|Right-hand end plate<br>~~SF~~<br>~~es~~|–<br>~~SF~~<br>~~es~~<br>~~ee~~|**195714**<br>~~SF~~<br>~~es~~|**CPX-EPR-EV**<br>~~SF~~<br>~~es~~<br>~~ee~~|
||With extension<br>~~es~~<br>~~ee~~|**576313**<br>~~es~~|**CPX-EPR-EV-X**<br>~~es~~<br>~~ee~~|
|Earthing component for right-hand/left-hand end plate<br>~~es~~|5 pieces<br>~~es~~<br>~~ee~~|**538892**<br>~~es~~|**CPX-EPFE-EV**<br>~~es~~<br>~~ee~~|
|||||
|lates for metal design<br>~~CT~~<br>~~esesee~~<br>~~2~~||||
|Left-hand end plate<br>~~es~~<br>~~2~~<br>~~—~~<br>~~f~~|–<br>~~ee~~<br>~~es~~<br>~~es~~|**550212**<br>~~ee~~<br>~~es~~<br>~~es~~|**CPX-M-EPL-EV**<br>~~ee~~<br>~~es~~<br>~~ee~~|
||With extension<br>~~es~~<br>~~es~~<br>~~a~~<br>~~f~~|**576317**<br>~~es~~<br>~~es~~<br>~~a~~<br>|**CPX-M-EPL-EV-X**<br>~~es~~<br>~~ee~~<br>~~a~~<br>|
|Right-hand end plate<br>~~es~~<br>~~2~~<br>~~—~~<br>~~f~~|–<br>~~es~~<br>~~es ~~<br>~~a~~<br>~~f~~|**550214**<br>~~es~~<br> ~~es ~~<br>~~a~~<br>|**CPX-M-EPR-EV**<br>~~es~~<br> ~~ee~~<br>~~a~~<br>|
||With extension<br>~~a~~<br>~~fff.~~|**576316**<br>~~a~~<br>~~ff.~~|**CPX-M-EPR-EV-X**<br>~~a~~<br>~~ff.~~|
|~~a~~<br>~~—~~<br>~~f~~||||
|pply<br>~~a~~<br>~~—~~<br>~~f~~<br>Se~~a~~<br>~~eeee~~<br>~~ee~~||||
|Plug socket for mains connection M18x1, straight,<br>4-pin<br>Plug socket for mains connection M18x1, angled,<br>4-pin<br>Se ~~a~~<br>~~Oe~~|For 1.5 mm2<br>~~ee~~<br>~~Oe~~<br>~~ee~~|**18493**<br>~~ee~~<br>~~Oe~~<br>~~ee~~|**NTSD-GD-9**<br>~~Oe~~|
||For 2.5 mm2<br>~~ee~~<br>~~Oe~~<br>~~ee~~|**18526**<br>~~ee~~<br>~~Oe~~<br>~~ee~~|**NTSD-GD-13.5**<br>~~Oe~~|
||For 1.5 mm2<br>~~ee ~~<br>~~Oe~~<br>~~ee~~|**18527**<br> ~~ee~~<br>~~Oe~~<br>~~ee~~|**NTSD-WD-9**<br>~~Oe~~|
||For 2.5 mm2<br>~~Oe~~<br>~~ee~~|**533119**<br>~~Oe~~<br>~~ee~~|**NTSD-WD-11**<br>~~Oe~~|
|Plugsocket for mains connection 7/8", straight, 5-pin<br>Plug socket for mains connection 7/8", straight, 4-pin<br>~~Oe~~<br>~~SP~~<br>~~-~~<br>~~ew|~~<br>~~|~~|0.25 ... 2.0 mm2<br>~~Oe~~<br>~~ee~~<br>~~SP~~|**543107**<br>~~Oe~~<br>~~ee~~<br>~~SP~~|**NECU-G78G5-C2**<br>~~Oe~~<br>~~SP~~|
||0.25 ... 2.0 mm2<br>~~Oe~~<br>~~ee~~<br>~~SP~~|**543108**<br>~~Oe~~<br>~~ee~~<br>~~SP~~|**NECU-G78G4-C2**<br>~~Oe~~<br>~~SP~~|
|Plug socket for mains connection 7/8", angled, 5-pin – open ca-<br>ble end, 5-wire<br>~~-~~<br>~~ew|~~<br>~~|~~<br>~~EA~~~~**a**~~|2 m<br>~~**a**~~|**573855**<br>~~**a**~~|**NEBU-G78W5-K-2-N-LE5**<br>~~**a**~~|
|Power supplysocket M12x1, L-coded, straight<br>Power supply plug M12x1, L-coded, straight<br>~~-~~<br>~~ew |~~<br>~~|~~<br>~~EA~~~~**a**~~|5-pin<br>~~**a**~~|**8166793**<br>~~**a**~~|**NECL-L12G5-C2-Q10**<br>~~**a**~~|
||5-pin<br>~~**a**~~|**8166791**<br>~~**a**~~|**NECL-S-L12G5-C2-Q10**<br>~~**a**~~|
|Power supplysocket M12x1, L-coded, angled<br>Power supply plug M12x1, L-coded, angled<br>~~EA~~~~**a**~~<br>~~Bo~~<br>~~0~~<br>~~ee~~|5-pin<br>~~**a**~~<br>~~Bo~~|**8166794**<br>~~**a**~~<br>~~Bo~~|**NECL-L12W5-C2-Q10**<br>~~**a**~~<br>~~PT~~<br>~~Bo~~|
||5-pin<br>~~**a**~~<br>~~Bo~~<br>~~ee~~|**8166792**<br>~~**a**~~<br>~~Bo~~<br>~~ee~~|**NECL-S-L12W5-C2-Q10**<br>~~**a**~~<br>~~Bo~~<br>~~ee~~|
|Push-pull power supply socket, plug pattern PP, fulfils require-<br>ments to AIDA<br>~~0~~<br>~~ee~~<br>ge<br>|~~[|i~~|5-pin<br>~~ee~~<br>~~[|i~~|**5195383**<br>~~ee~~<br>~~[|i~~|**NECU-M-PPG5PP-C1-PN**<br>~~ee~~<br>~~[|i~~|
|Straight plug, spring-loaded terminal, for left-hand end plate<br>with system supply<br>~~0~~<br>~~ee~~<br>ge<br>|~~[|i~~|7-pin<br>~~ee~~<br>~~[|i~~|**576319**<br>~~ee~~<br>~~[|i~~|**NECU-L3G7-C1**<br>~~ee~~<br>~~[|i~~|
Subject to change – 2023/10
52
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet
**==> picture [523 x 347] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data – Accessories<br>Designation Part no. Type<br>Inscription labels<br>Inscription labels 6x10 mm, 64 pieces, in frame 18576 IBS-6x10<br>Hood<br>Mounting rail for attaching the hood 1000 mm 572256 CAFC-X1-S<br>Mounting kit for CPX hood 572257 CAFC-X1-BE<br>Hood section for CPX terminal including mounting attachments 200 mm 572258 CAFC-X1-GAL-200<br>for connecting several hood sections in series. 300 mm 572259 CAFC-X1-GAL-300<br>User documentation<br>CPX system manual German 526445 P.BE-CPX-SYS-DE<br>English 526446 P.BE-CPX-SYS-EN<br>Spanish 526447 P.BE-CPX-SYS-ES<br>French 526448 P.BE-CPX-SYS-FR<br>Italian 526449 P.BE-CPX-SYS-IT<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
53
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet
## **User documentation – General information**
Comprehensive user documentation is vital for the fast and reliable use of fieldbus components.
The manuals provided by Festo contain step-by-step instructions for using the CPX terminal:
1. Installation
2. Commissioning and parameterisation
3. Diagnostics
Application-oriented explanations are provided for integrating the CPX terminal in the programming and configuration software of the various controller manufacturers.
Use the order code to select the language you want.
The manuals for the configuration you have ordered are supplied automatically.
**==> picture [60 x 55] intentionally omitted <==**
The documents can be downloaded quickly and easily from the Festo website a www.festo.com.
|**Overview – User documentation**<br>Type<br>Title<br>Description|**Overview – User documentation**<br>Type<br>Title<br>Description|**Overview – User documentation**<br>Type<br>Title<br>Description|
|---|---|---|
|**Pneumatics**|||
|P.BE-VTSA-44-...|Valve terminals with VTSA and VTSA-F pneu-<br>matics|Instructions on assembly, installation, commissioning and diagnostics of the VTSA and<br>VTSA-Fpneumatic components.|
|P.BE-MPA-...|Valve terminals with MPA-S pneumatics|Instructions on assembly, installation, commissioning and diagnostics of the MPA-S pneu-<br>matic components.|
|MPAL-VI-...|Valve terminal|Instructions on assembly, installation, commissioning and diagnostics of the MPA-L pneu-<br>matic components.|
Subject to change – 2023/10
d **Internet: www.festo.com/catalogue/...**
54
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet
## **Overview – User documentation**
**==> picture [523 x 408] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type Title Description<br>Electronics<br>P.BE-CPX-SYS-... System description, installation and commis- Overview of the design, components and mode of operation of the CPX terminal; installa-<br>sioning tion and commissioning instructions as well as basic principles of parameterisation.<br>CPX-FVDA-P2-... PROFIsafe shut-off module Connection technology and assembly, installation and commissioning instructions for the<br>PROFIsafe shut-off module of the type CPX-FVDA-P2.<br>P.BE-CPX-EA-... CPX-EA modules, digital Connection technology and assembly, installation and commissioning instructions for digi-<br>tal input and output modules of type CPX-... as well as the VTSA/VTSA-F and MPA-S/L pneu-<br>matic interface.<br>P.BE-CPX-P-EA-... Input module CPX-P-8DE-N Connection technology and assembly, installation and commissioning instructions for the<br>digital input module for NAMUR sensors of type CPX-P-8DE-N.<br>CPX-F8DE-P-... Input module CPX-F8DE-N Connection technology and assembly, installation and commissioning instructions for the<br>PROFIsafe input module of type CPX-F8DE-P.<br>P.BE-CPX-2ZE2DA-... I/O-module CPX-2ZE2DA Connection technology and assembly, installation and commissioning instructions for<br>counter modules of type CPX-2ZE2DA.<br>P.BE-CPX-AX-... CPX-EA modules, analogue Connection technology and assembly, installation and commissioning instructions for ana-<br>logue input and output modules of type CPX-...<br>as well as pressure sensors and proportional pressure regulators.<br>P.BE-CPX-CP... CPX CP interface Instructions on assembly, installation, commissioning and diagnostics of the CP interface.<br>P.BE-CPX-CTEL... CPX CTEL interface Instructions on assembly, installation, commissioning and diagnostics of the CPX CTEL<br>master.<br>P.BE-CPX-CTEL-LK... Electrical interface CPX-CTEL-2 Instructions on assembly, installation, commissioning and diagnostics for the CPX electri-<br>cal interface for IO-Link.<br>CPX-CM-HPP... CPX axis interface Instructions on assembly, installation, commissioning and diagnostics of the CPX axis in-<br>terface (CM-HPP).<br>P.BE-CPX-CMAX-SYS... CPX axis controller Instructions on assembly, installation, commissioning and diagnostics of the CPX axis con-<br>troller (CMAX).<br>P.BE-CPX-CMAX-CONTROL... CPX axis controller Information on control, diagnostics and parameterisation of the axis controller via the<br>fieldbus.<br>P.BE-CPX-CMPX-SYS... CPX end-position controller Instructions on assembly, installation, commissioning and diagnostics of the CPX end-po-<br>sition controller (CMPX).<br>P.BE-CPX-CMIX... CPX measuring module Instructions on assembly, installation, commissioning and diagnostics of the CPX measur-<br>ing module (CMIX).<br>P.BE-CPX-FB... CPX bus node Instructions on assembly, installation, commissioning and diagnostics of the relevant bus<br>CPX-... node.<br>CPX-(M)-FB33_35/43_45... CPX bus node for PROFINET Instructions on assembly, installation, commissioning and diagnostics of the relevant bus<br>node.<br>P.BE-CPX-CEC... CPX CODESYS controller (control block) Instructions on assembly, installation, commissioning and diagnostics of the relevant con-<br>trol block.<br>**----- End of picture text -----**<br>
## **User documentation – GSD, EDS, ...**
Device description files and icons are used to explain the integration of the CPX terminal in the configuration software of the various controller manufacturers.
These can be downloaded quickly and easily from www.festo.com.
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
55
Terminal CPX
## Data sheet – CPX Maintenance Tool
## **Function**
The CPX Maintenance Tool (CPX-FMT) combines service software with a connecting adapter. The service software is a tool for the design, parameterisation and online diagnostics of the CPX terminal.
- Adapters
• Software on CD-ROM
The USB-to-M12 adapter features built-in galvanic isolation (between CPX and PC) and enables a PC to be connected to the diagnostic interface of the CPX terminal.
## **Application**
Only from Festo
The CPX-FMT software enables access to CPX valve terminals via Ethernet with the bus nodes EtherNet/IP (FB 36), Sercos III (FB 39) and PROFINET (FB 33, FB 34, FB 35, FB 41, FB 45). The bus nodes or control blocks can be connected directly to a PC via a USB adapter from Festo. Diagnostic data such as the error trace or module diagnostics can be read out and parameters can be modified in plain text.
The data can be used directly on a PC. There is an option, for example, to send screenshots of a configuration or the current error trace directly via e-mail. In addition, CPX configurations can also be saved and archived directly as a CPX-FMT project. Undocumented changes can subsequently be identified using the online/offline comparison function.
On-site tests such as the actuation of valves or the emulation of sensor feedback (in both cases called "forcing"), for example, can be carried out without an existing controller infrastructure.
It must be noted that with the CPX-FMT, only local parameters on the CPX valve terminal can be changed and saved. The configuration of the networks or controller software cannot be influenced.
## **General technical data**
|**General technical data**<br>Type<br>NEFC-M12G5-0.3-U1G5<br>System requirements<br>PC<br>IBM-compatible<br>Drive<br>CD-ROM<br>Interfaces<br>USBport (specification USB 1.1 or higher)<br>Operatingsystem<br>Microsoft Windows 2000 or XP|**General technical data**<br>Type<br>NEFC-M12G5-0.3-U1G5<br>System requirements<br>PC<br>IBM-compatible<br>Drive<br>CD-ROM<br>Interfaces<br>USBport (specification USB 1.1 or higher)<br>Operatingsystem<br>Microsoft Windows 2000 or XP|
|---|---|
||CD-ROM|
||USBport (specification USB 1.1 or higher)|
||Microsoft Windows 2000 or XP|
|Function range|• Configuration and parameterisation<br>• Reading out of system, module, channel diagnostics and error trace<br>• Saving of the configuration as a project<br>• Integration ofplug-ins/links to self-executing programs|
|Scope of delivery|• Adapter, M12, 5-pin to mini USB socket<br>• CD-ROM with installationprogram|
|Type of mounting|Screw-in|
|Electrical connection|PlugM12x1, 5-pin|
|Adapter cable composition|4 x 0.34 mm2|
|Cable length<br>[m]|0.3|
|Degree ofprotection to EN 60529|IP20|
|CE marking(see declaration of conformity)1)|To EU RoHS Directive|
|UKCA marking(see declaration of conformity)1)|To UK RoHS instructions|
|Ambient temperature<br>[°C]|–5 ... +50|
|Material<br>Housing<br>Cable sheath<br>Pin contact|ABS|
||PUR|
||Gold-plated brass|
|Note on materials|RoHS-compliant|
|PWIS conformity|VDMA24364-B2-L|
- 1) Additional information: www.festo.com/catalogue/... d Support/Downloads.
Subject to change – 2023/10
56
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – CPX Maintenance Tool
**==> picture [524 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions Download CAD data a www.festo.com<br>[1] Mini B 5P USB port<br>[2] Plug M12x1, 5-pin<br>Ordering data<br>Designation Part no. Type<br>CPX Maintenance Tool (CPX-FMT), software and USB-to-M12 adapter 547432 NEFC-M12G5-0.3-U1G5<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
57
Terminal CPX
## Data sheet – CPX-IOT gateway
- Industrial Ethernet
- TCP/IP
- OPC UA
- Web interface
- Gateway for continuous transfer of operating data from connected Festo components to a central storage location (MQTT broker).
- Comprehensive status information for the gateway is displayed using 7 specific LEDs.
The gateway can only be used as a combination with end plates and an interlinking block; no additional CPX modules are possible.
## **Application**
## Data collection
The CPX-IOT gateway gathers information and transfers it to a central storage location (user-specific MQTT broker).
The transfer takes place using secure protocols. The customer can only connect to the internet via a firewall. The extent of the data gathered and transferred is determined by the evaluation software (app).
Advantages:
- The central controller of the machine or system does not require an internet connection
- Operating data are available outside the system
## Prerequisites
- Connected components must have corresponding evaluation software (app)
- Internet connection
- Components to be monitored have an Industrial Ethernet interface
- MQTT broker
Information that can be evaluated (depending on the software):
- (Energy) consumption monitoring
- Preventive maintenance
- Visualisation of overall equipment effectiveness
- Identification data
- Diagnostic data
- Parameter data
- Operating status data
Interfaces
Onward communication between the gateway and the central storage location (MQTT broker) is via an Industrial Ethernet interface with M12x1 plug, D-coded to IEC 947-5-2.
The operating mode of the gateway is set using a rotary switch. This enables simple interruption of this network connection on site.
Communication with the components Both connections have auto-negotiabeing monitored is also via an Industrition and crossover detection as factory al Ethernet interface with M12x1 plug, settings. D-coded to IEC 947-5-2.
Subject to change – 2023/10
58
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – CPX-IOT gateway
## **Design**
**==> picture [455 x 235] intentionally omitted <==**
**----- Start of picture text -----**<br>
5 |<br>7<br>9<br>1 2<br>va 3<br>8 10<br>6 L E<br>3<br> in LES |<br>KN # PTE<br>3<br>2<br>te Se giv? ae<br>°<br>SC<br>4<br>**----- End of picture text -----**<br>
- [1] PLC to machine/system controller [3] Festo components with bus con(no direct internet connection) nection with serial linking
- nection with serial linking
- [2] Bus system from the controller to [4] Components from which the CPXthe system parts (e.g. PROFINET) IOT is collecting and transferring data
- [5] Gateway CPX-IOT
- [6] Internet connection
- [9] Central storage location (user-specific MQTT broker) provided by Festo
- [7] Customer firewall or other security precautions
- [8] Transferring data to a central stor[10] Simple decentralised evaluation age location (MQTT broker) using of data using adapted programs secure protocols (apps) for the components that are being monitored
2023/10 – Subject to change
59
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – CPX-IOT gateway
**==> picture [524 x 567] intentionally omitted <==**
**----- Start of picture text -----**<br>
General technical data<br>Type CPX-IOT<br>Fieldbus interface Protocol Ethernet<br>OPC UA<br>Function Bus connection to Ethernet-based Festo devices<br>Connection type Socket<br>Connection technology M12x1, D-coded to EN 61076-2-101<br>Number of pins/wires 4<br>Galvanic isolation Yes<br>Transmission rate [Mbps] 100<br>Ethernet interface Protocol TCP/IP<br>Function Connection to MQTT broker<br>Connection type Socket<br>Connection technology M12x1, D-coded to EN 61076-2-101<br>Number of pins/wires 4<br>Transmission rate [Mbps] 10<br>[Mbps] 100<br>CPU data Dual core 533 MHz<br>256 MB RAM<br>Configuration support Integrated web server<br>Diagnostics via LED Modify<br>Module location<br>Network status<br>Network status port 1<br>Network status port 2<br>Power supply, electronics/sensors<br>Power supply load<br>System error<br>Connection to the cloud<br>Control elements Rotary switch for setting operating mode<br>DIL switch for resetting to delivery status<br>IP address setting DHCP<br>Static via web server<br>Technical data – Electrics<br>Nominal operating voltage DC for electronics/sensors [V DC] 24<br>Permissible voltage fluctuations for electronic system/sensors [%] ±25<br>Power failure buffering [ms] 10<br>Intrinsic current consumption at nominal operating voltage for electronic system/ [mA] Typically 80<br>sensors<br>Protection against direct and indirect contact PELV<br>Technical data – Mechanical components<br>Type of mounting With H-rail<br>Product weight [g] 130<br>Grid dimension [mm] 50<br>Dimensions W x L x H [mm] 50 x 107 x 50<br>Materials<br>Housing PA<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
60
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – CPX-IOT gateway
**==> picture [523 x 102] intentionally omitted <==**
**----- Start of picture text -----**<br>
Operating and environmental conditions<br>Ambient temperature [°C] – 5... +50<br>Storage temperature [°C] – 20... +70<br>Relative humidity [%] 95<br>Non-condensing<br>Corrosion resistance class CRC [1)] 0<br>CE marking (see declaration of conformity) [3)] To EU EMC Directive [2)]<br>Degree of protection IP65<br>IP67<br>**----- End of picture text -----**<br>
- 1) Additional information: www.festo.com/x/topic/kbk
- 2) For information about the area of use, see the EC declaration of conformity at: www.festo.com/catalogue/... d Support/Downloads.
- If the devices are subject to usage restrictions in residential, commercial or light-industrial environments, further measures for the reduction of the emitted interference may be necessary.
- 3) Additional information: www.festo.com/catalogue/... d Support/Downloads.
|**Safety characteristics**<br>Shock resistance<br>Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27|**Safety characteristics**<br>Shock resistance<br>Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27|
|---|---|
|Vibration resistance|Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6|
**==> picture [523 x 153] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection and display components<br>[1] Network-specific LED displays<br>[2] Gateway-specific LED displays<br>1 2<br>[3] Connection to MQTT broker<br>(M12x1 socket, 4-pin, D-coded)<br>[4] Transparent switch cover<br>3<br>[5] Bus connection to Ethernet-based<br>4 Festo devices (M12x1 socket,<br>4-pin, D-coded)<br>5<br>**----- End of picture text -----**<br>
## **Pin allocation for MQTT broker connection and bus connection to Ethernet-based Festo devices**
**==> picture [523 x 90] intentionally omitted <==**
**----- Start of picture text -----**<br>
Terminal allocation Pin Signal Designation<br>M12x1 socket, D-coded<br>1 TD+ Transmitted data+<br>2 RD+ Received data+<br>3 TD- Transmitted data-<br>4 RD- Received data-<br>Housing Shielding Connected to functional earth (FE) via RC link<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
61
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – CPX-IOT gateway
**==> picture [524 x 411] intentionally omitted <==**
**----- Start of picture text -----**<br>
Combinations of interlinking blocks and gateway<br>Interlinking blocks Part no. Gateway<br>CPX-IOT<br>CPX-GE-EV-S 195746 h<br>CPX-GE-EV-S-VL 8022170 –<br>CPX-GE-EV-S-7/8-4POL 541248 –<br>CPX-GE-EV-S-7/8-5POL 541244 h<br>CPX-GE-EV-S-7/8-5POL-VL 8022172 –<br>CPX-M-GE-EV-S-7/8-CIP-4P 568956 –<br>CPX-M-GE-EV-S-7/8-5POL 550208 –<br>CPX-M-GE-EV-S-7/8-5POL-VL 8022165 –<br>CPX-M-GE-EV-S-PP-5POL 563057 –<br>CPX-GE-EV 195742 h<br>CPX-M-GE-EV 550206 –<br>CPX-M-GE-EV-FVO 567806 –<br>CPX-GE-EV-Z 195744 –<br>CPX-GE-EV-Z-VL 8022166 –<br>CPX-GE-EV-Z-7/8-4POL 541250 –<br>CPX-GE-EV-Z-7/8-5POL 541246 –<br>CPX-GE-EV-Z-7/8-5POL-VL 8022173 –<br>CPX-M-GE-EV-Z-7/8-5POL 550210 –<br>CPX-M-GE-EV-Z-7/8-5POL-VL 8022158 –<br>CPX-M-GE-EV-S-M12-5POL 8098392 –<br>CPX-M-GE-EV-Z-PP-5POL 563058 –<br>CPX-GE-EV-V 533577 –<br>CPX-GE-EV-V-VL 8022171 –<br>CPX-GE-EV-V-7/8-4POL 541252 –<br>CPX-M-GE-EV-W-M12-5POL 8098391 –<br>Combinations of end plates and gateway<br>End plates Part no. Gateway<br>CPX-IOT<br>CPX-EPL-EV 195716 h<br>CPX-EPL-EV-S 576315 h<br>CPX-EPL-EV-X 576314 –<br>CPX-EPR-EV 195714 h<br>CPX-EPR-EV-X 576313 –<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
62
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – CPX-IOT gateway
**==> picture [523 x 563] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>Gateway<br>8069773 CPX-IOT<br>Bus connection<br>Connecting cable, Straight plug, M12x1, 0.5 m 8040446 NEBC-D12G4-ES-0.5-S-D12G4-ET<br>straight plug, M12x1, 4-pin, D-coded 1 m 8040447 NEBC-D12G4-ES-1-S-D12G4-ET<br>4-pin, D-coded 3 m 8040448 NEBC-D12G4-ES-3-S-D12G4-ET<br>5 m 8040449 NEBC-D12G4-ES-5-S-D12G4-ET<br>10 m 8040450 NEBC-D12G4-ES-10-S-D12G4-ET<br>Straight plug, RJ45, 8-pin 1 m 8040451 NEBC-D12G4-ES-1-S-R3G4-ET<br>3 m 8040452 NEBC-D12G4-ES-3-S-R3G4-ET<br>5 m 8040453 NEBC-D12G4-ES-5-S-R3G4-ET<br>10 m 8040454 NEBC-D12G4-ES-10-S-R3G4-ET<br>Open end, 4-wire 5 m 8040456 NEBC-LE4-ES-5-D12G4-ET<br>Cover cap for sealing unused bus connections (10 pieces) 165592 ISK-M12<br>Tie rod<br>Tie rod CPX Tie rod CPX 1-module 195718 CPX-ZA-1<br>Interlinking block<br>Without power supply – 195742 CPX-GE-EV<br>With system supply M18 195746 CPX-GE-EV-S<br>7/8" – 5-pin 541244 CPX-GE-EV-S-7/8-5POL<br>End plates<br>Left-hand end plate Without supply 195716 CPX-EPL-EV<br>With system supply 576315 CPX-EPL-EV-S<br>Right-hand end plate – 195714 CPX-EPR-EV<br>Earthing component for right-hand/left-hand end plate 5 pieces 538892 CPX-EPFE-EV<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
63
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – CPX-IOT gateway
**==> picture [524 x 404] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>Power supply<br>Plug socket for mains connection M18x1, Straight For 1.5 mm [2] 18493 NTSD-GD-9<br>4-pin For 2.5 mm [2] 18526 NTSD-GD-13.5<br>Angled For 1.5 mm [2] 18527 NTSD-WD-9<br>For 2.5 mm [2] 533119 NTSD-WD-11<br>Plug socket for mains connection 7/8", straight, 5-pin 0.25 ... 2.0 mm [2] 543107 NECU-G78G5-C2<br>Plug socket for mains connection 7/8", angled, 5-pin – open cable end, 5-wire 2 m 573855 NEBU-G78W5-K-2-N-LE5<br>Straight plug, spring-loaded terminal, for left-hand end plate with system supply 7-pin 576319 NECU-L3G7-C1<br>Cover<br>Inspection cover, transparent 533334 AK-SUB-9/15-B<br>Mounting<br>Mounting for H-rail 526032 CPX-CPA-BG-NRH<br>Inscription labels<br>Inscription labels 6x10 mm, 64 pieces, in frame 18576 IBS-6x10<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
64
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – CODESYS controller
**==> picture [521 x 398] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|• Industrial Ethernet|The CODESYS controller is a modern|
|• TCP/IP|control system for CPX terminals that|
|at ae|
|• EasyIP|enables programming with CODESYS to|cc|
|• Web interface|IEC 61131-3.|.|=|
|• Email|The power supply to and communica-|
|• Data transfer|tion with other modules takes place via|
|the interlinking block.|
|In addition to network connections,|
|LEDs are also provided for the bus sta-|
|tus, operating status of the PLC and|
|CPX peripherals information, as are|
|switching elements and a diagnostic|
|interface for CPX-FMT.|
|Application|
|Bus connection|Communication protocols|Operating modes|
|The CPX-CEC is a remote controller that|At the same time, it is possible to op-|• Fieldbus via CPX bus nodes|• Stand-alone|
|can be connected to a higher-order PLC|erate the CPX-CEC as a compact stand-|• Modbus/TCP|• Remote controller, fieldbus|
|via the bus nodes of the CPX terminal|alone controller directly on the ma-|• EasyIP|• Remote controller, Ethernet|
|or via Ethernet.|chine.|
|Setting options|
|The CPX-CEC has the following interfac-|• For the CPX-FMT|The operating mode and fieldbus pro-|The integrated web server offers a con-|
|es for monitoring, programming and|• Ethernet interface for IT applications|tocol are set using the DIL switch on|venient means of querying data saved|
|commissioning:|• Remote diagnostics|the CPX-CEC.|in the CPX-CEC.|
|Features|
|• Easy control of valve terminal config-|• Activation of decentralised installa-|• Connection to all fieldbuses as a re-|• Early warnings and visualisation op-|
|urations with MPA, VTSA|tion systems on the basis of CPI con-|mote controller and for preprocess-|tions|
|• Diagnostics with flexible monitoring|trol of applications in proportional|ing|• Servo-pneumatic applications|
|options for pressure, flow rate, cyl-|pneumatics|• Control of electric actuators as indi-|
|inder operating time, air consump-|• AS-Interface control via gateway|vidual axes via CANopen (CPX-CEC-|
|tion|C1/-M1)|
**----- End of picture text -----**<br>
2023/10 – Subject to change
65
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – CODESYS controller
**==> picture [524 x 596] intentionally omitted <==**
**----- Start of picture text -----**<br>
General technical data<br>Protocol CODESYS Level 2<br>EasyIP<br>Modbus TCP<br>TCP/IP<br>Processing time Approx. 200 μs/1 k instructions<br>Programming software CODESYS provided by Festo<br>Programming language To IEC 61131-3<br>Sequential function chart (SFC)<br>Instruction list (IL)<br>Function chart (FCH), additional continuous function chart (CFC)<br>Ladder diagram (LD)<br>Structured text (ST)<br>Programming Operating language German, English<br>Support for file handling Yes<br>Device-specific diagnostics Diagnostic memory<br>Channel and module-oriented diagnostics<br>Undervoltage/short-circuit modules<br>LED displays Bus-specific TP: Link/traffic<br>Product-specific RUN: PLC status<br>STOP: PLC status<br>ERR: PLC runtime error<br>PS: Electronics supply, sensor supply<br>PL: Load supply<br>SF: System fault<br>M: Modify/forcing active<br>IP address setting DHCP<br>Via CODESYS<br>Via MMI<br>Function blocks CPX diagnostic status, copy CPX diagnostic trace, read CPX module diagnostics, and more<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 55<br>Materials<br>Housing PA-reinforced<br>PC<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Operating and environmental conditions<br>Ambient temperature [°C] –5 ... +50<br>Storage temperature [°C] –20 ... +70<br>Relative humidity [%] 95, non-condensing<br>Corrosion resistance class CRC [1)] 2<br>1) Additional information: www.festo.com/x/topic/kbk<br>Electrical data<br>Nominal operating voltage [V DC] 24<br>Load voltage Nominal operating voltage [V DC] 24<br>With pneumatics type VTSA [V DC] 21.6 ... 26.4<br>With pneumatics type MPA [V DC] 18 ... 30<br>Without pneumatics [V DC] 18 ... 30<br>Power failure buffering [ms] 10<br>Intrinsic current consumption at nominal operating voltage [mA] Typically 85<br>Degree of protection to EN 60529 IP65, IP67<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
66
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – CODESYS controller
## **Technical data**
**==> picture [523 x 547] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type CPX-CEC-C1 CPX-CEC-C1-V3 CPX-CEC-M1-V3<br>Additional functions Motion functions for electric drives SoftMotion functions for<br>electric drives<br>CPU data Flash [MB] 32 32 32<br>RAM [MB] 32 256 256<br>Processor [MHz] 400 800 800<br>Control interface CAN bus CAN bus CAN bus<br>Parameterisation CODESYS V2.3 CODESYS V3 CODESYS V3<br>Configuration support CODESYS V2.3 CODESYS V3 CODESYS V3<br>Program memory, user program [MB] 4 16 16<br>Flags CODESYS variable concept<br>Remanent data [kB] 30 28 28<br>Global data memory [MB] 8 – –<br>Control elements DIL switch for CAN termination<br>Rotary switch for RUN/STOP<br>Total number of axes 31 127 31<br>Ethernet Number 1<br>Connection technology RJ45 socket, 8-pin<br>Data transmission speed [Mbps] 10/100<br>Supported protocols TCP/IP, EasyIP, Modbus TCP<br>Fieldbus interface Number 1<br>Connection technology Sub-D plug, 9-pin<br>Data transmission speed, can be set [kbps] 125, 250, 500, 800, 1000 125, 250, 500, 800, 1000 125, 250, 500, 800, 1000<br>via software<br>Supported protocols CAN bus<br>Galvanic isolation Yes<br>Technical data<br>Type CPX-CEC CPX-CEC-S1-V3<br>CPU data Flash [MB] 32 32<br>RAM [MB] 32 256<br>Processor [MHz] 400 800<br>Parameterisation CODESYS V2.3 CODESYS V3<br>Configuration support CODESYS V2.3 CODESYS V3<br>Additional functions Diagnostic functions<br>RS232 communication function<br>Program memory, user program [MB] 4 16<br>Flags CODESYS variable concept CODESYS variable concept<br>Remanent data [kB] 30 28<br>Global data memory [MB] 8 –<br>Control elements Rotary switch for RUN/STOP<br>Ethernet Number 1<br>Connection technology RJ45 socket, 8-pin<br>Data transmission speed [Mbps] 10/100<br>Supported protocols TCP/IP, EasyIP, Modbus TCP<br>Data interface Number 1<br>Connection technology Sub-D socket, 9-pin<br>Data transmission speed [kbps] 9.6 ... 230.4<br>Supported protocols RS232 interface<br>Max. cable length [m] – 30<br>Galvanic isolation Yes<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
67
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – CODESYS controller
## **Connection and display elements CPX-CEC-C1/-M1**
- [1] CPX-FMT connection
**==> picture [69 x 69] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>2<br>3<br>**----- End of picture text -----**<br>
**==> picture [69 x 83] intentionally omitted <==**
**----- Start of picture text -----**<br>
4<br>5<br>6<br>**----- End of picture text -----**<br>
**==> picture [39 x 51] intentionally omitted <==**
- [2] DIL switch
- [3] Fieldbus interface (Sub-D plug, 9-pin)
- [4] Status LEDs, bus-specific and product-specific
- [5] RUN/STOP rotary switch
- [6] Ethernet interface (RJ45 socket,
- 8-pin)
## **Pin allocation – CPX-CEC-C1/-M1**
**==> picture [524 x 245] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pin Signal Meaning<br>Fieldbus interface, Sub-D plug<br>1 n.c. Not connected<br>2 CAN_L CAN low<br>3 CAN_GND CAN ground<br>4 n.c. Not connected<br>5 CAN_SHLD Connection to functional earth FE<br>6 CAN_GND CAN ground (optional) [1)]<br>7 CAN_H CAN high<br>8 n.c. Not connected<br>9 n.c. Not connected<br>Housing Shielding Plug housing must be connected to FE<br>Ethernet interface, RJ45 plug<br>1 TD+ Transmitted data+<br>2 TD- Transmitted data-<br>3 RD+ Received data+<br>4 n.c. Not connected<br>5 n.c. Not connected<br>6 RD- Received data-<br>7 n.c. Not connected<br>8 n.c. Not connected<br>Housing Shielding Shielding<br>**----- End of picture text -----**<br>
- 1) If a servo drive is connected to an external power supply, CAN ground (optional), pin 6, cannot be used on the CPX-CEC-C1/-M1.
Subject to change – 2023/10
68
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – CODESYS controller
## **Connection and display elements CPX-CEC/CPX-CEC-S1-V3**
- [1] CPX-FMT connection
**==> picture [69 x 69] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>2<br>3<br>**----- End of picture text -----**<br>
**==> picture [69 x 83] intentionally omitted <==**
**----- Start of picture text -----**<br>
4<br>5<br>6<br>**----- End of picture text -----**<br>
- [2] DIL switch
- [3] RS232 interface (Sub-D socket, 9-pin)
- [4] Status LEDs, bus-specific and product-specific
- [5] RUN/STOP rotary switch
- [6] Ethernet interface (RJ45 socket, 8-pin)
## **Pin allocation – CPX-CEC/CPX-CEC-S1-V3**
**==> picture [523 x 245] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pin Signal Meaning<br>RS 232 interface, Sub-D socket<br>1 n.c. Not connected<br>2 RxD Received data<br>3 TxD Transmitted data<br>4 n.c. Not connected<br>5 GND Data reference potential<br>6 n.c. Not connected<br>7 n.c. Not connected<br>8 n.c. Not connected<br>9 n.c. Not connected<br>Shielding Shielding Connection to functional earth<br>Ethernet interface, RJ45 plug<br>1 TD+ Transmitted data+<br>2 TD- Transmitted data-<br>3 RD+ Received data+<br>4 n.c. Not connected<br>5 n.c. Not connected<br>6 RD- Received data-<br>7 n.c. Not connected<br>8 n.c. Not connected<br>Housing Shielding Shielding<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
69
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – CODESYS controller
**==> picture [524 x 519] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>Control block<br>Motion functions for electric drives CODESYS V2.3 155 g 567347 CPX-CEC-C1<br>CODESYS V3 135 g 3473128 CPX-CEC-C1-V3<br>SoftMotion functions for electric drives CODESYS V3 135 g 3472765 CPX-CEC-M1-V3<br>RS232 communication function CODESYS V2.3 155 g 567346 CPX-CEC<br>CODESYS V3 135 g 3472425 CPX-CEC-S1-V3<br>Fieldbus interface<br>Sub-D plug, 9-pin, for CANopen 532219 FBS-SUB-9-BU-2x5POL-B<br>Micro style bus connection, 2xM12 for DeviceNet/CANopen 525632 FBA-2-M12-5POL<br>Socket for micro style connection, M12 18324 FBSD-GD-9-5POL<br>Plug for micro style connection, M12 175380 FBS-M12-5GS-PG9<br>Open style bus connection for 5-pin terminal strip for DeviceNet/CANopen 525634 FBA-1-SL-5POL<br>Terminal strip for open style connection, 5-pin 525635 FBSD-KL-2x5POL<br>Ethernet interface<br>RJ45 plug Degree of protection IP 65, IP67 534494 FBS-RJ45-8-GS<br>Cover for RJ45 connection Degree of protection IP 65, IP67 534496 AK-RJ45<br>Straight plug, RJ45, 8-pin Straight plug, M12x1, Degree of protec- 1 m 8040451 NEBC-D12G4-ES-1-S-R3G4-ET<br>4-pin, D-coded tion IP20 3 m 8040452 NEBC-D12G4-ES-3-S-R3G4-ET<br>5 m 8040453 NEBC-D12G4-ES-5-S-R3G4-ET<br>10 m 8040454 NEBC-D12G4-ES-10-S-R3G4-ET<br>Straight plug, RJ45, 8-pin Straight plug, RJ45, Degree of protec- 1 m 8040455 NEBC-R3G4-ES-1-S-R3G4-ET<br>8-pin tion IP20<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
70
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – CODESYS controller
**==> picture [523 x 188] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>Covers and attachments<br>Inspection cover, transparent, for Sub-D connection 533334 AK-SUB-9/15-B<br>Inscription label holder for connection block 536593 CPX-ST-1<br>User documentation<br>Manual for control block CPX-CEC German 569121 P.BE-CPX-CEC-DE<br>English 569122 P.BE-CPX-CEC-EN<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
71
Terminal CPX
## Data sheet – DeviceNet bus node
Bus node for handling communication between the electrical terminal CPX and a DeviceNet network. The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules.
The status of the CPX terminal is displayed as a common message via 4 CPX-specific LEDs. The fieldbus communication status is displayed via the three DeviceNet-specific LEDs.
## **Application**
## Bus connection
The bus connection can be selected when ordering, either micro style as 2xM12 round plugs or open style as a terminal strip with IP20 protection.
Both connection types have the function of an integrated T-distributor with incoming and outgoing bus line.
## DeviceNet implementation
The CPX-FB11 operates with the Predefined Master/Slave Connection Set as a Group 2 Only Server. The polled I/O, change of state or cyclic method is used for the transmission of cyclic I/O data. The type of transmission can be selected in the network configuration.
The device diagnostics for all bus nodes CPX-FB11 is effectively gathered via strobed I/O and displayed in the input table of the controller. In addition to cyclic data transmission, acyclic communication is supported through explicit messaging, which enables detailed device diagnostics and parameterisation.
A comprehensive EDS file supports the display of acyclic data. It is also possible to display system information and assign parameters while the controller is running via the user program or the configuration software.
An example of this is access to the integrated diagnostic memory function, i.e. storage of the last 40 errors with timestamp, module, channel and error type.
With its address capacity of 64 byte inputs and 64 byte outputs, the CPXFB11 supports any configuration of I/O modules, including pneumatic interface.
## Points to note in connection with CPX-CEC
When a bus node is combined with a control block (CPX-CEC, in the fieldbus remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX control block.
In this case, the bus node only provides the communication interface to the PLC. Communication between the control block and CPX bus node takes place by interlinking the CPX modules and takes
up the following address capacity in the CPX system: • 8 byte outputs • 8 byte inputs The following address capacity remains in the control block or CPX system for activating the peripherals:
• 56 byte inputs • 56 byte outputs
72 d **Internet: www.festo.com/catalogue/...** Subject to change – 2023/10
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – DeviceNet bus node
## **General technical data**
**==> picture [523 x 376] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type CPX-FB11<br>Fieldbus interface Either<br>• Micro style bus connection: 2xM12 with degree of protection IP65, IP67<br>• Open style bus connection: 5-pin terminal strip, IP20<br>Baud rate [kbps] 125, 250, 500<br>Addressing range 0 ... 63<br>Set using DIL switch<br>Product Type Communication adapter (12 dec.)<br>Code 4554 dec.<br>Types of communication Polled I/O, change of state/cyclic, strobed I/O and explicit messaging<br>Configuration support EDS file and bitmaps<br>Max. address capacity Inputs [byte] 64<br>Outputs [byte] 64<br>LED displays (bus-specific) MS = Module status<br>NS = Network status<br>IO = I/O status<br>Device-specific diagnostics Module and channel-oriented diagnostics via manufacturer-specific diagnostic object<br>Parameterisation • Module and system parameterisation via configuration interface in plain text (EDS)<br>• Online in run or program mode<br>Additional functions • Storage of the last 40 errors with timestamp (access via EDS)<br>• 8-bit system status in image table for inputs<br>• 2-byte inputs and 2-byte outputs, system diagnostics in process image<br>Control elements DIL switch<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Power failure buffering [ms] 10<br>Current consumption [mA] Typically 200<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Materials Reinforced PA, PC<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 120<br>**----- End of picture text -----**<br>
## - **Note** H-
Please observe the general limits and guidelines for the system when configuring the electrical modules.
2023/10 – Subject to change
73
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – DeviceNet bus node
## **Connection and display components**
**==> picture [166 x 133] intentionally omitted <==**
**----- Start of picture text -----**<br>
MS PS<br>NS PL<br>1 IO SF 2<br>M<br>4 3<br>**----- End of picture text -----**<br>
- [1] Bus-specific LEDs [2] CPX-specific status LEDs [3] Selectable fieldbus interface – Micro style – Open style
- [4] DIL switch cover
**==> picture [524 x 423] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pin allocation for the DeviceNet interface<br>Terminal allocation Pin Signal-specific wire Signal Designation<br>colour [1)]<br>Sub-D plug<br>1 – n.c. Not connected<br>2 Blue CAN_L Received/transmitted data low<br>3 Black 0 V bus 0 V CAN interface<br>4 – n.c. Not connected<br>5 Bare Shielding Connection to housing<br>6 – n.c. Not connected<br>7 White CAN_H Received/transmitted data high<br>8 – n.c. Not connected<br>9 Red 24 V DC bus 24 V DC supply CAN interface<br>Micro style bus connection (M12), incoming/outgoing<br>Incoming 1 Bare Shielding Connection to housing<br>2 Red 24 V DC bus 24 V DC supply CAN interface<br>3 Black 0 V bus 0 V CAN interface<br>4 White CAN_H Received/transmitted data high<br>5 Blue CAN_L Received/transmitted data low<br>Outgoing 1 Bare Shielding Connection to housing<br>2 Red 24 V DC bus 24 V DC supply CAN interface<br>3 Black 0 V bus 0 V CAN interface<br>4 White CAN_H Received/transmitted data high<br>5 Blue CAN_L Received/transmitted data low<br>Open style bus connection<br>1 Black 0 V bus 0 V CAN interface<br>2 Blue CAN_L Received/transmitted data low<br>3 Bare Shielding Connection to housing<br>1 2 3 4 5 4 White CAN_H Received/transmitted data high<br>5 Red 24 V DC bus 24 V DC supply CAN interface<br>7/8" bus connection<br>1 Black Shielding Connection to housing<br>2 Blue 24 V DC 24 V DC supply CAN interface<br>3 Bare 0 V 0 V CAN interface<br>4 White CAN_H Received/transmitted data high<br>5 Red CAN_L Received/transmitted data low<br>**----- End of picture text -----**<br>
- 1) Typical of DeviceNet connecting cables
Subject to change – 2023/10
d **Internet: www.festo.com/catalogue/...**
74
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – DeviceNet bus node
**==> picture [525 x 584] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>Bus node<br>DeviceNet bus node 526172 CPX-FB11<br>Bus connection<br>Sub-D plug 532219 FBS-SUB-9-BU-2x5POL-B<br>Connection block, 9-pin Sub-D socket, 5-pin 7/8" plug 571052 CPX-AB-1-7/8-DN<br>Micro style bus connection, 2xM12 525632 FBA-2-M12-5POL<br>Socket for micro style connection, M12 18324 FBSD-GD-9-5POL<br>Plug for micro style connection, M12 175380 FBS-M12-5GS-PG9<br>Open style bus connection for 5-pin terminal strip 525634 FBA-1-SL-5POL<br>Terminal strip for open style connection, 5-pin 525635 FBSD-KL-2x5POL<br>Inspection cover, transparent 533334 AK-SUB-9/15-B<br>Inscription label holder for connection block 536593 CPX-ST-1<br>5-pin M12 to mini USB socket adapter and controller software 547432 NEFC-M12G5-0.3-U1G5<br>User documentation<br>User documentation for bus node CPX-FB11 German 526421 P.BE-CPX-FB11-DE<br>English 526422 P.BE-CPX-FB11-EN<br>Spanish 526423 P.BE-CPX-FB11-ES<br>French 526424 P.BE-CPX-FB11-FR<br>Italian 526425 P.BE-CPX-FB11-IT<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
75
Terminal CPX
## Data sheet – PROFIBUS bus node
Bus node for handling communication between the electrical terminal CPX and a higher-order master via PROFIBUS DP. The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules. The status of the CPX terminal is displayed as a common message via 4 CPX-specific LEDs. The fieldbus communication status is displayed via the PROFIBUS-specific error LED.
## **Application**
## Bus connection
The bus connection is established via The bus connector plug (with degree of a 9-pin Sub-D socket with a typical protection IP65/IP67 from Festo or dePROFIBUS allocation (to EN 50170). gree of protection IP20 from other manufacturers) facilitates the connection of an incoming and an outgoing bus cable.
An active bus terminal can be connected using the DIL switch integrated in the plug.
The Sub-D interface is designed for controlling network components with a fibre-optic cable connection.
## PROFIBUS DP implementation
The CPX-FB13 supports the PROFIBUS In addition to DPV0, acyclic communiDP protocol to EN 50170 Volume 2 for cation to the advanced specification cyclic I/O exchange, parameterisation DPV1 is supported. DPV1 provides acyand diagnostic functions (DPV0). clic access to advanced system information and allows parameterisation while the controller is running via the user program.
An example of this is access to the integrated diagnostic memory function, i.e. storage of the last 40 errors with timestamp, module, channel and error type.
With its address capacity of 64 byte inputs and 64 byte outputs, the CPXFB13 supports any configuration of I/O modules, including pneumatic interface.
## Points to note in connection with CPX-CEC
When a bus node is combined with a control block (CPX-CEC, in the fieldbus remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX control block.
In this case, the bus node only provides the communication interface to the PLC. Communication between the control block and CPX bus node takes place by interlinking the CPX modules and takes up the following address capacity in the CPX system:
## • 8 byte outputs
• 8 byte inputs
The following address capacity re-
mains in the control block or CPX system for activating the peripherals:
- 56 byte inputs
- 56 byte outputs
Subject to change – 2023/10
76
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – PROFIBUS bus node
## **General technical data**
**==> picture [523 x 352] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type CPX-FB13<br>Fieldbus interface Sub-D socket, 9-pin (EN 50170)<br>Galvanically isolated 5 V<br>Baud rate [Mbps] 0.0096 ... 12<br>Addressing range 1 ... 125<br>Set using DIL switch<br>Product family 4: Valves<br>ID number 0x059E<br>Types of communication DPV0: Cyclic communication<br>DPV1: Acyclic communication<br>Configuration support GSD file and bitmaps<br>Max. address capacity Inputs [byte] 64<br>Outputs [byte] 64<br>LED displays (bus-specific) BF: Bus fault<br>Device-specific diagnostics Identifier and channel-oriented diagnostics to EN 50170 (PROFIBUS standard)<br>Parameterisation • Start-up parameterisation via configuration interface in plain text (GSD)<br>• Acyclic parameterisation via DPV1<br>Additional functions • Storage of the last 40 errors with timestamp (access via DPV1)<br>• 8-bit system status in image table for inputs<br>• 2-byte inputs and 2-byte outputs, system diagnostics in process image<br>Control elements DIL switch<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Power failure buffering [ms] 10<br>Current consumption [mA] Typically 200<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Materials Reinforced PA, PC<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 115<br>**----- End of picture text -----**<br>
## - **Note** H-
Please observe the general limits and guidelines for the system when configuring the electrical modules.
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
77
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – PROFIBUS bus node
## **Connection and display components**
**==> picture [341 x 135] intentionally omitted <==**
**----- Start of picture text -----**<br>
[1] Bus status LEDs/bus fault<br>�� �<br>�� [2] CPX-specific status LEDs<br>1 ���� 2 [3] Fieldbus interface (Sub-D socket, 9-pin)<br>[4] DIL switch cover<br>4 3<br>**----- End of picture text -----**<br>
## **Pin allocation for PROFIBUS DP interface**
**==> picture [524 x 287] intentionally omitted <==**
**----- Start of picture text -----**<br>
Terminal allocation Pin Signal Designation<br>Sub-D socket<br>1 n.c. Not connected<br>2 n.c. Not connected<br>3 RxD/TxD-P Received/transmitted data P<br>4 CNTR-P [1)] Repeater control signal<br>5 DGND Data reference potential (M5V)<br>6 VP Supply voltage (P5V)<br>7 n.c. Not connected<br>8 RxD/TxD-N Received/transmitted data N<br>9 n.c. Not connected<br>Housing Shielding Connection to housing<br>Bus connection M12 adapter (B-coded)<br>Incoming 1 n.c. Not connected<br>2 RxD/TxD-N Received/transmitted data N<br>3 n.c. Not connected<br>4 RxD/TxD-P Received/transmitted data P<br>5 and Shielding Connection to FE (functional earth)<br>M12<br>Outgoing 1 VP Supply voltage (P5V)<br>2 RxD/TxD-N Received/transmitted data N<br>3 DGND Data reference potential (M5V)<br>4 RxD/TxD-P Received/transmitted data P<br>5 and Shielding Connection to FE (functional earth)<br>M12<br>**----- End of picture text -----**<br>
1) The repeater control signal CNTR-P is realised as a TTL signal.
Subject to change – 2023/10
78
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – PROFIBUS bus node
**==> picture [523 x 483] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>Bus node<br>PROFIBUS bus node 195740 CPX-FB13<br>Bus connection<br>Sub-D plug, straight, with terminating resistor and programming interface 574589 NECU-S1W9-C2-APB<br>Sub-D plug, straight 532216 FBS-SUB-9-GS-DP-B<br>Sub-D plug, angled 533780 FBS-SUB-9-WS-PB-K<br>Bus connection M12 adapter (B-coded) 533118 FBA-2-M12-5POL-RK<br>Connection block M12 adapter (B-coded) 541519 CPX-AB-2-M12-RK-DP<br>5-pin M12x1 straight socket, 1067905 NECU-M-B12G5-C2-PB<br>for self-assembly of a connecting cable compatible with FBA-2-M12-5POL-RK and CPX-AB-2-M12-RK-DP<br>Plug M12x1, 5-pin, straight, 1066354 NECU-M-S-B12G5-C2-PB<br>for self-assembly of a connecting cable compatible with FBA-2-M12-5POL-RK and CPX-AB-2-M12-RK-DP<br>Terminating resistor, M12, B-coded for PROFIBUS 1072128 CACR-S-B12G5-220-PB<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
79
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – PROFIBUS bus node
## **Ordering data**
**==> picture [524 x 233] intentionally omitted <==**
**----- Start of picture text -----**<br>
Designation Part no. Type<br>Bus connection<br>Inspection cover, transparent 533334 AK-SUB-9/15-B<br>Inscription label holder for connection block M12 536593 CPX-ST-1<br>5-pin M12 to mini USB socket adapter and controller software 547432 NEFC-M12G5-0.3-U1G5<br>User documentation<br>User documentation for bus node CPX-FB13 German 526427 P.BE-CPX-FB13-DE<br>English 526428 P.BE-CPX-FB13-EN<br>Spanish 526429 P.BE-CPX-FB13-ES<br>French 526430 P.BE-CPX-FB13-FR<br>Italian 526431 P.BE-CPX-FB13-IT<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
80
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – CANopen bus node
Bus node for handling communication between the electrical terminal CPX and a CANopen network master or CANopen network. The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules.
The status of the CPX terminal is displayed as a common message via 4 CPX-specific LEDs. The different CANopen statuses and the fieldbus communication status are visualised via 3 additional LEDs. **Application** Bus connection The bus connection is established via The bus connector plug (with degree of There are 4 contacts available for the a 9-pin Sub-D plug (pin) as per the CAN protection IP65/IP67 from Festo or de4 wires (CAN_L, CAN_H, 24 V, 0 V) of in Automation (CiA) specification gree of protection IP20 from other the incoming and outgoing bus cables DS 102 with additional 24 V CAN manufacturers) facilitates the connecrespectively. transceiver supply (option as per tion of an incoming and an outgoing DS 102). bus cable. CANopen implementation The CPX-FB14 supports the CANopen Enhanced system information can also With its address capacity, the CPX8 analogue input channels and 8 anaprotocol in accordance with the specifibe accessed via SDO communication. FB14 supports a large number of I/O logue output channels can be adcations DS 301 V4.01 and DS 401 SDO communication also facilitates module configurations, including dressed via PDO 2 and 3. Status and V2.0. parameterisation before network startpneumatic interface. diagnostic information can be evaluatImplementation is based on the CiA up or while the controller is running via By default, 8 byte digital inputs and 8 ed via PDO 4. Predefined Connection Set. the user program. byte digital outputs can be addressed Additional 8 byte digital inputs and There are 4 PDOs available for fast I/O An example of this is access to the invia PDO 1. outputs as well as 8 analogue input data exchange. tegrated diagnostic memory function, and output channels can be addressed i.e. storage of the last 40 errors with via mapping. timestamp, module, channel and error type. Points to note in connection with CPX-CEC When a bus node is combined with a In this case, the bus node only proup the following address capacity in • 56 byte inputs control block (CPX-CEC, in the fieldbus vides the communication interface to the CPX system: • 56 byte outputs remote controller operating mode), the the PLC. • 8 byte outputs connected I/Os and/or valves, sensors Communication between the control • 8 byte inputs and actuators are controlled via the block and CPX bus node takes place by The following address capacity reCPX control block. interlinking the CPX modules and takes mains in the control block or CPX system for activating the peripherals:
2023/10 – Subject to change
81
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – CANopen bus node
## **General technical data**
**==> picture [524 x 437] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type CPX-FB14<br>Fieldbus interface Sub-D plug, 9-pin (to DS 102)<br>Bus interface galvanically isolated via optocoupler 24 V supply for CAN interface via bus<br>Baud rate [kbps] 125, 250, 500 and 1000 can be set via DIL switch<br>Addressing range Node ID 1 ... 127<br>Set using DIL switch<br>Product family Digital inputs and outputs<br>Communication profile DS 301, V4.01<br>Device profile DS 401, V2.0<br>Number PDO 4 Tx/4 Rx<br>SDO 1 server SDO<br>Configuration support EDS file and bitmaps<br>Max. address capacity Inputs [byte] 16 digital, 16 analogue channels<br>Outputs [byte] 16 digital, 16 analogue channels<br>LED displays (bus-specific) MS = Module status<br>NS = Network status<br>IO = I/O status<br>Device-specific diagnostics Via emergency message<br>Object 1001, 1002 and 1003<br>Parameterisation Via SDO<br>Additional functions • Storage of the last 40 errors with timestamp (access via SDO)<br>• 8-bit system status via transmit PDO 4 (default)<br>• 2-byte inputs and 2-byte outputs, system diagnostics via PDO 4<br>• Minimum boot-up<br>• Variable PDO mapping<br>• Emergency message<br>• Node guarding<br>• Heart beat<br>Control elements DIL switch<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Power failure buffering [ms] 10<br>Current consumption [mA] Typically 200<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Materials Reinforced PA, PC<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 115<br>**----- End of picture text -----**<br>
## - **Note** H-
Please observe the general limits and guidelines for the system when configuring the electrical modules.
Subject to change – 2023/10
82
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – CANopen bus node
## **Connection and display components**
|||||2|
|---|---|---|---|---|
|||||3|
||||||
||||||
||||||
||||||
[1] Bus-specific LEDs [2] CPX-specific status LEDs [3] Fieldbus interface (Sub-D plug, 9-pin) [4] DIL switch cover
**==> picture [523 x 348] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pin allocation of the CANopen interface<br>Terminal allocation Pin Signal Designation<br>Sub-D plug<br>1 n.c. Not connected<br>2 CAN_L Received/transmitted data low<br>3 CAN_GND 0 V CAN interface<br>4 n.c. Not connected<br>5 CAN_SHLD Optional shielded connection<br>6 GND Ground [1)]<br>7 CAN_H Received/transmitted data high<br>8 n.c. Not connected<br>9 CAN_V+ 24 V DC supply CAN interface<br>Housing Shielding Connection to FE (functional earth)<br>Micro style bus connection (M12)<br>Incoming 1 Shielding Connection to FE (functional earth)<br>2 CAN_V+ 24 V DC supply CAN interface<br>3 CAN_GND 0 V CAN interface<br>4 CAN_H Received/transmitted data high<br>5 CAN_L Received/transmitted data low<br>Outgoing 1 Shielding Connection to FE (functional earth)<br>2 CAN_V+ 24 V DC supply CAN interface<br>3 CAN_GND 0 V CAN interface<br>4 CAN_H Received/transmitted data high<br>5 CAN_L Received/transmitted data low<br>Open style bus connection<br>1 CAN_GND 0 V CAN interface<br>2 CAN_L Received/transmitted data low<br>3 Shielding Connection to FE (functional earth)<br>1 2 3 4 5 4 CAN_H Received/transmitted data high<br>5 CAN_V+ 24 V DC supply CAN interface<br>**----- End of picture text -----**<br>
1) Connected internally via Pin 3
2023/10 – Subject to change
83
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – CANopen bus node
**==> picture [524 x 687] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>Bus node<br>CANopen bus node 526174 CPX-FB14<br>Bus connection<br>Sub-D socket for CANopen with terminating resistor and programming interface 574588 NECU-S1W9-C2-ACO<br>Sub-D socket 532219 FBS-SUB-9-BU-2x5POL-B<br>Sub-D socket, angled 533783 FBS-SUB-9-WS-CO-K<br>Connection block, 9-pin Sub-D socket, 5-pin 7/8" plug 571052 CPX-AB-1-7/8-DN<br>Micro style bus connection, 2xM12, 5-pin 525632 FBA-2-M12-5POL<br>Fieldbus socket for micro style connection, M12, 5-pin 18324 FBSD-GD-9-5POL<br>Plug for micro style connection, M12, 5-pin 175380 FBS-M12-5GS-PG9<br>Open style bus connection 525634 FBA-1-SL-5POL<br>Terminal strip for open style connection, 5-pin 525635 FBSD-KL-2x5POL<br>Inspection cover, transparent 533334 AK-SUB-9/15-B<br>Inscription label holder for connection block 536593 CPX-ST-1<br>5-pin M12 to mini USB socket adapter and controller software 547432 NEFC-M12G5-0.3-U1G5<br>User documentation<br>User documentation for bus node CPX-FB14 German 526409 P.BE-CPX-FB14-DE<br>English 526410 P.BE-CPX-FB14-EN<br>Spanish 526411 P.BE-CPX-FB14-ES<br>French 526412 P.BE-CPX-FB14-FR<br>Italian 526413 P.BE-CPX-FB14-IT<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
84
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – CC-Link bus node
Bus node for handling communication between the electrical terminal CPX and a higher-order master for Control & Communication-Link (CC-Link) from Mitsubishi.
The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules.
The status of the CPX terminal is displayed as a common message via 4 CPX-specific LEDs. The fieldbus communication status is displayed via 4 CC-Link-specific LEDs.
## **Application**
Bus connection
The bus connection can be selected when ordering and is established via a screw terminal with degree of protection IP20, a Sub-D plug with degree of
protection IP65/IP67 from Festo or degree of protection IP20 from other manufacturers.
Both connection types have the function of an integrated T-distributor and thus support the connection of an incoming and outgoing bus cable.
## CC-Link implementation
The CPX bus node CPX-FB23-24 optionally supports the CC-Link versions 2.0 (as function module F24) and 1.1 (as function module F23). These designations are also found in the system diagram for the CPX Maintenance Tool (CPX-FMT) from Festo.
Function module F24 corresponds to CC-Link version 2.0 and supports a maximum of four stations per slave, up to an address capacity of 64 bytes of digital I/O and 64 bytes of analogue I/O in each case. It is possible to optimise the configuration of the addressing in terms of either cycle time or station.
Function module F23 corresponds to CC-Link version 1.1 and supports a maximum of four stations per slave, up to an address capacity of 32 bytes of digital I/O and 14 bytes of analogue I/O in each case.
The function module and option are set using the DIL switch on the CPX bus node.
## Points to note in connection with CPX-CEC
When a bus node is combined with a control block (CPX-CEC, in the fieldbus remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX control block.
In this case, the bus node only provides the communication interface to the PLC.
Communication between the control block and CPX bus node takes place by interlinking the CPX modules and takes
up the following address capacity in • 56 byte inputs the CPX system: • 56 byte outputs
• 8 byte outputs
• 8 byte inputs The following address capacity remains in the control block or CPX system for activating the peripherals:
2023/10 – Subject to change
85
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – CC-Link bus node
## **General technical data**
**==> picture [524 x 439] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type CPX-FB23-24<br>Fieldbus interface Either<br>• Sub-D socket, 9-pin<br>• Sub-D plug, for self-assembly<br>• Screw terminal strip, IP20<br>Baud rate [kbps] 156 ... 10000<br>Protocol CC-Link<br>Max. address capacity, inputs FB23 RWr [byte] 32<br>Rx [byte] 14<br>FB24 RWr [byte] 64<br>Rx [byte] 64<br>Max. address volume for outputs FB23 RWw [byte] 32<br>Ry [byte] 14<br>FB24 RWw [byte] 64<br>Ry [byte] 64<br>LED displays (bus-specific) RUN = Communication status<br>ERROR = Communication error<br>SD = Send data<br>RD = Receive data<br>Device-specific diagnostics • Diagnostic memory<br>• Channel and module-oriented diagnostics<br>• Undervoltage of modules<br>Parameterisation • Diagnostic behaviour<br>• Fail-safe response<br>• Forcing of channels<br>• Signal setup<br>• System parameters<br>Additional functions • System status can be displayed using process data<br>• Additional diagnostic interface for operator units<br>Control elements DIL switch<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Current consumption [mA] Typically 200<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Materials Reinforced PA, PC<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 115<br>**----- End of picture text -----**<br>
## - **Note** H-
Please observe the general limits and guidelines for the system when configuring the electrical modules.
Subject to change – 2023/10
86
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – CC-Link bus node
## **Connection and display components**
**==> picture [166 x 134] intentionally omitted <==**
**----- Start of picture text -----**<br>
RUN PS<br>PL<br>1 SD SF 2<br>RD M<br>4 3<br>**----- End of picture text -----**<br>
[1] Bus-specific status LEDs
- [2] CPX-specific status LEDs
- [3] Fieldbus interface (Sub-D socket, 9-pin)
- [4] DIL switch cover
## **Pin allocation for the CC-Link interface**
**==> picture [523 x 211] intentionally omitted <==**
**----- Start of picture text -----**<br>
Terminal allocation Pin Signal Designation<br>Sub-D socket<br>1 n.c. Not connected<br>2 DA Data A<br>3 DG Data reference potential<br>4 n.c. Not connected<br>5 FE [1)] Functional earth<br>6 n.c. Not connected<br>7 DB Data B<br>8 n.c. Not connected<br>9 n.c. Not connected<br>Screw terminal bus connection<br>1 FG Functional earth/housing<br>2 SLD Shielding<br>3 DG Data reference potential<br>4 DB Data B<br>5 DA Data A<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
87
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – CC-Link bus node
**==> picture [524 x 367] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>Bus node<br>CC-Link bus node 526176 CPX-FB23-24<br>Bus connection<br>Sub-D plug 532220 FBS-SUB-9-GS-2x4POL-B<br>Inspection cover, transparent 533334 AK-SUB-9/15-B<br>Inscription label holder for connection block 536593 CPX-ST-1<br>5-pin M12 to mini USB socket adapter and controller software 547432 NEFC-M12G5-0.3-U1G5<br>User documentation<br>User documentation for bus node CPX-FB23-24 German 526403 P.BE-CPX-FB23-24-DE<br>English 526404 P.BE-CPX-FB23-24-EN<br>Chinese 8026069 P.BE-CPX-FB23-24-ZH<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
88
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – PROFINET bus node, M12, D-coded
Bus node for operating the CPX valve terminal on PROFINET.
The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules.
The status of the CPX terminal is displayed as a common message via 4 CPX-specific LEDs. The fieldbus communication status is displayed via three bus-specific LEDs.
## **Application**
## Bus connection
The bus connection is established via two M12 sockets, D-coded to IEC 61076-2-101 with degree of protection IP65, IP67.
Both connections are equivalent 100BaseTX Ethernet ports with integrated auto MDI functionality (crossover and patch cables can be used) that are brought together via an internal switch.
- Maximum segment length 100 m • Transmission rate 100 Mbps
## PROFINET implementation
The bus nodes support the PROFINET protocol on the basis of the Ethernet standard and TCP/IP technology to IEEE802.3. This guarantees a data exchange with a high data transmission rate, for example I/O data from sensors, actuators or robot controllers, PLCs or process equipment. In addition, non-real-time critical information such as diagnostic
information, configuration information, etc. can be transferred. The Ethernet bandwidth is sufficient to transfer both data types (real-time and non-realtime) in parallel.
The bus node features LEDs for bus
status and CPX peripheral information as well as switch elements and a diagnostic interface. PROFINET provides the user with access to all peripherals, diagnostic data and parameter data of the CPX valve terminal. The bus node can be used as a remote I/O or remote controller. All information relevant to the CPX can be read out and, depend-
ent on the function, changed via CPX-FMT.
## Points to note in connection with CPX-CEC
When a bus node is combined with a control block (CPX-CEC, in the fieldbus remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX control block.
In this case, the bus node only provides the communication interface to the PLC.
Communication between the control block and CPX bus node takes place by interlinking the CPX modules and takes
up the following address capacity in • 56 byte inputs the CPX system: • 56 byte outputs
- 8 byte outputs
• 8 byte inputs The following address capacity remains in the control block or CPX system for activating the peripherals:
2023/10 – Subject to change
89
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – PROFINET bus node, M12, D-coded
**==> picture [524 x 557] intentionally omitted <==**
**----- Start of picture text -----**<br>
General technical data<br>Type CPX-FB43<br>Fieldbus interface 2x socket, M12, 4-pin, D-coded<br>Baud rate [Mbps] 100<br>Protocol PROFINET RT<br>PROFINET IRT<br>Max. address capacity Inputs [byte] 64<br>Outputs [byte] 64<br>LED displays (bus-specific) M/P = Maintenance/PROFIenergy<br>NF = Network fault<br>TP1 = Network active port 1<br>TP2 = Network active port 2<br>(product-specific) M = Modify, parameterisation<br>PL = Load supply<br>PS = Electronic supply, sensor supply<br>SF = System fault<br>Device-specific diagnostics • Channel and module-oriented diagnostics<br>• Undervoltage of modules<br>• Diagnostic memory<br>Configuration support GSDML file<br>Parameterisation • System parameters<br>• Diagnostic behaviour<br>• Signal setup<br>• Fail-safe response<br>• Forcing of channels<br>Additional functions • Start-up parameterisation in plain text via fieldbus<br>• Fast start-up (FSU)<br>• Channel-oriented diagnostics via fieldbus<br>• Acyclic data access via fieldbus and via Ethernet<br>• System status can be displayed using process data<br>• Additional diagnostic interface for operator unit<br>• I&M<br>• LLDP<br>• MRP<br>• MRPD<br>• MQTT<br>• PROFIsafe<br>• PROFIenergy<br>• S2 system redundancy<br>Control elements • DIL switch<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Current consumption [mA] Typically 70<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] – 5... +50<br>Storage/transport [°C] –20 ... +70<br>Certification RCM<br>Materials Housing Die-cast aluminium<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 185<br>**----- End of picture text -----**<br>
## - **Note** H-
Please observe the general limits and guidelines for the system when configuring the electrical modules.
## - **Note** H-
Always use the correct screws for the interlinking block; this depends on whether the block is made of metal or plastic:
• Self-tapping screws for plastic in• Screws with metric thread for metterlinking blocks al interlinking blocks
Subject to change – 2023/10
90
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
Data sheet – PROFINET bus node, M12, D-coded
## **Connection and display components**
**==> picture [337 x 138] intentionally omitted <==**
**----- Start of picture text -----**<br>
[1] Bus-specific status LEDs<br>[2] CPX-specific status LEDs<br>1 2 [3] Fieldbus interface (M12 socket,<br>4 4-pin, D-coded)<br>[4] Transparent cover for DIL switch<br>3 3<br>**----- End of picture text -----**<br>
**==> picture [523 x 121] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pin allocation for the fieldbus interface<br>Terminal allocation Pin Signal Designation<br>Socket, M12, D-coded<br>1 TD+ Transmitted data+<br>2 RD+ Received data+<br>3 TD- Transmitted data-<br>4 RD- Received data-<br>Housing Shielding<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
91
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – PROFINET bus node, M12, D-coded
**==> picture [524 x 419] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>Bus node<br>PROFINET bus node • I&M 8110369 CPX-FB43<br>• LLDP<br>• MRP<br>• MRPD<br>• PROFIenergy<br>• S2 system redundancy<br>Bus connection<br>Plug M12x1, 4-pin, D-coded 543109 NECU-M-S-D12G4-C2-ET<br>Connecting cable, Straight plug, M12x1, 0.5 m 8040446 NEBC-D12G4-ES-0.5-S-D12G4-ET<br>straight plug, M12x1, 4-pin, D-coded 1 m 8040447 NEBC-D12G4-ES-1-S-D12G4-ET<br>4-pin, D-coded 3 m 8040448 NEBC-D12G4-ES-3-S-D12G4-ET<br>5 m 8040449 NEBC-D12G4-ES-5-S-D12G4-ET<br>10 m 8040450 NEBC-D12G4-ES-10-S-D12G4-ET<br>Straight plug, RJ45, 1 m 8040451 NEBC-D12G4-ES-1-S-R3G4-ET<br>8-pin 3 m 8040452 NEBC-D12G4-ES-3-S-R3G4-ET<br>5 m 8040453 NEBC-D12G4-ES-5-S-R3G4-ET<br>10 m 8040454 NEBC-D12G4-ES-10-S-R3G4-ET<br>Open end, 4-wire 5 m 8040456 NEBC-LE4-ES-5-D12G4-ET<br>Transparent cover for DIL switch 548757 CPX-AK-P<br>Cover cap for sealing unused bus connections (10 pieces) 165592 ISK-M12<br>User documentation<br>Electronics manual, CPX bus node German 548759 CPX-(M)-FB33_35/43_45-DE<br>English 548760 CPX-(M)-FB33_35/43_45-EN<br>Spanish 548761 CPX-(M)-FB33_35/43_45-ES<br>French 548762 CPX-(M)-FB33_35/43_45-FR<br>Italian 548763 CPX-(M)-FB33_35/43_45-IT<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
92
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – PROFINET bus node, push-pull RJ45
Bus node for operating the CPX valve terminal on PROFINET.
The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules.
The status of the CPX terminal is displayed as a common message via 4 CPX-specific LEDs. The fieldbus communication status is displayed via 4 bus-specific LEDs.
## **Application**
## Bus connection
The bus connection is established via two RJ45 push-pull sockets to IEC 61076-3-106 and IEC 60603 with degree of protection IP65, IP67.
Both connections are equivalent 100BaseTX Ethernet ports with integrated auto MDI functionality (crossover and patch cables can be used) that are brought together via an internal switch.
- Maximum segment length 100 m • Transmission rate 100 Mbps
## PROFINET implementation
information, configuration information, etc. can be transferred.
The bus nodes support the PROFINET protocol on the basis of the Ethernet etc. can be transferred. standard and TCP/IP technology to The Ethernet bandwidth is sufficient to IEEE802.3. transfer both data types (real-time and This guarantees a data exchange with non-real-time) in parallel.
This guarantees a data exchange with a high data transmission rate, for example I/O data from sensors, actuators or robot controllers, PLCs or process equipment. In addition, non-real-time critical information such as diagnostic
The bus nodes feature LEDs for bus status and CPX peripheral information as well as switch elements and a diagnostic interface. PROFINET provides the user with access to all peripherals, diagnostic data and parameter data of the CPX valve terminal. The bus node can be used as a remote I/O or remote controller. All information relevant to the CPX can be read out and, depend-
ent on the function, changed via CPX-FMT.
## Points to note in connection with CPX-CEC
When a bus node is combined with a control block (CPX-CEC, in the fieldbus remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX control block.
In this case, the bus node only provides the communication interface to the PLC.
Communication between the control block and CPX bus node takes place by interlinking the CPX modules and takes
up the following address capacity in • 56/48 byte inputs the CPX system: • 56/48 byte outputs • 8/16 byte outputs • 8/16 byte inputs The following address capacity remains in the control block or CPX system for activating the peripherals:
2023/10 – Subject to change
93
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – PROFINET bus node, push-pull RJ45
**==> picture [524 x 556] intentionally omitted <==**
**----- Start of picture text -----**<br>
General technical data<br>Type CPX-M-FB44<br>Fieldbus interface 2x RJ45 push-pull socket, AIDA<br>Baud rate [Mbps] 100<br>Protocol PROFINET RT<br>PROFINET IRT<br>Max. address capacity Inputs [byte] 64<br>Outputs [byte] 64<br>LED displays (bus-specific) M/P = Maintenance/PROFIenergy<br>NF = Network fault<br>TP1 = Network active port 1<br>TP2 = Network active port 2<br>(product-specific) M = Modify, parameterisation<br>PL = Load supply<br>PS = Electronic supply, sensor supply<br>SF = System fault<br>Device-specific diagnostics • Channel and module-oriented diagnostics<br>• Undervoltage of modules<br>• Diagnostic memory<br>Configuration support GSDML file<br>Parameterisation • System parameters<br>• Diagnostic behaviour<br>• Signal setup<br>• Fail-safe response<br>• Forcing of channels<br>Additional functions • Start-up parameterisation in plain text via fieldbus<br>• Fast start-up (FSU)<br>• Channel-oriented diagnostics via fieldbus<br>• Acyclic data access via fieldbus and via Ethernet<br>• System status can be displayed using process data<br>• Additional diagnostic interface for operator unit<br>• I&M<br>• LLDP<br>• MRP<br>• MRPD<br>• MQTT<br>• PROFIsafe<br>• PROFIenergy<br>• S2 system redundancy<br>Control elements • DIL switch<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Intrinsic current consumption at nominal operating voltage [mA] Typically 70<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] – 5... +50<br>Storage/transport [°C] –20 ... +70<br>Certification RCM<br>Housing material Die-cast aluminium<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 80<br>Product weight [g] 280<br>**----- End of picture text -----**<br>
## - **Note** H-
Please observe the general limits and guidelines for the system when configuring the electrical modules.
## - **Note** H-
Always use the correct screws for the • Self-tapping screws for plastic in• Screws with metric thread for metinterlinking block; this depends on terlinking blocks al interlinking blocks whether the block is made of metal or plastic:
Subject to change – 2023/10
94
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – PROFINET bus node, push-pull RJ45
## **Connection and display components**
**==> picture [337 x 138] intentionally omitted <==**
**----- Start of picture text -----**<br>
[1] Bus-specific status LEDs<br>[2] CPX-specific status LEDs<br>1 2 [3] Fieldbus interface (RJ45 socket,<br>4 8-pin)<br>[4] DIL switch<br>3 3<br>**----- End of picture text -----**<br>
## **Pin allocation for the fieldbus interface**
**==> picture [523 x 123] intentionally omitted <==**
**----- Start of picture text -----**<br>
Terminal allocation Pin Signal Designation<br>RJ45 socket<br>1 TD+ Transmitted data+<br>2 TD- Transmitted data-<br>3 RD+ Received data+<br>4 n.c. Not connected<br>5 n.c. Not connected<br>6 RD- Received data-<br>7 n.c. Not connected<br>8 n.c. Not connected<br>Housing Shielding Shielding<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
95
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – PROFINET bus node, push-pull RJ45
**==> picture [524 x 373] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>Bus node<br>PROFINET bus node • I&M 8110370 CPX-M-FB44<br>• LLDP<br>• MRP<br>• MRPD<br>• PROFIenergy<br>• S2 system redundancy<br>Bus connection<br>RJ45 plug, 8-pin, push-pull 552000 FBS-RJ45-PP-GS<br>Cover cap for bus connection 548753 CPX-M-AK-C<br>Cover cap for bus connection 2873540 CPX-M-AK-D<br>Cover for DIL switch 548754 CPX-M-AK-M<br>User documentation<br>Electronics manual, CPX bus node German 548759 CPX-(M)-FB33_35/43_45-DE<br>English 548760 CPX-(M)-FB33_35/43_45-EN<br>Spanish 548761 CPX-(M)-FB33_35/43_45-ES<br>French 548762 CPX-(M)-FB33_35/43_45-FR<br>Italian 548763 CPX-(M)-FB33_35/43_45-IT<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
96
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – PROFINET bus node, push-pull SCRJ
Bus node for operating the CPX valve terminal on PROFINET.
The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules.
The status of the CPX terminal is displayed as a common message via 4 CPX-specific LEDs. The fieldbus communication status is displayed via three bus-specific LEDs.
## **Application** Bus connection
The bus connection is established via SCRJ push-pull sockets to IEC 6175424 (fibre-optic cable, AIDA standard) with degree of protection IP65, IP67.
The connections on the CPX bus node are equivalent 100BaseFX Ethernet ports that are brought together via an internal switch.
Fibre-optic cables made from plastic (POF, 980/1000 μm) are also suitable for transmission.
- Maximum segment length 50 m
- Transmission rate 100 Mbps
- Supports LLDP and SNMP
## PROFINET implementation
The bus nodes support the PROFINET protocol on the basis of the Ethernet standard and TCP/IP technology to IEEE802.3. This guarantees a data exchange with a high data transmission rate, for example I/O data from sensors, actuators or robot controllers, PLCs or process equipment. In addition, non-real-time critical information such as diagnostic
information, configuration information, etc. can be transferred. The Ethernet bandwidth is sufficient to transfer both data types (real-time and non-real-time) in parallel.
The bus node features LEDs for bus CPX can be read out and, dependent status and CPX peripheral information on the function, changed via CPX-FMT. as well as switch elements and a diagnostic interface. PROFINET provides the user with access to all peripheral, diagnostic and parameter data for the CPX valve terminal. The bus node can be used as a remote I/O or remote controller. All information relevant to the
## Points to note in connection with CPX-CEC
When a bus node is combined with a control block (CPX-CEC, in the fieldbus remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX control block.
In this case, the bus node only provides the communication interface to the PLC.
Communication between the control block and CPX bus node takes place by interlinking the CPX modules and takes
up the following address capacity in the CPX system:
- 8/16 byte outputs
- 8/16 byte inputs
The following address capacity remains in the control block or CPX system for activating the peripherals:
- 56/48 byte inputs • 56/48 byte outputs
2023/10 – Subject to change
97
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – PROFINET bus node, push-pull SCRJ
**==> picture [524 x 566] intentionally omitted <==**
**----- Start of picture text -----**<br>
General technical data<br>Type CPX-M-FB45<br>Fieldbus interface 2x SCRJ push-pull socket, AIDA<br>Baud rate [Mbps] 100<br>Protocol PROFINET RT<br>PROFINET IRT<br>Max. address capacity Inputs [byte] 64<br>Outputs [byte] 64<br>LED displays (bus-specific) M/P = Maintenance/PROFIenergy<br>NF = Network fault<br>TP1 = Network active port 1<br>TP2 = Network active port 2<br>(product-specific) M = Modify, parameterisation<br>PL = Load supply<br>PS = Electronic supply, sensor supply<br>SF = System fault<br>Device-specific diagnostics • Channel and module-oriented diagnostics<br>• Undervoltage of modules<br>• Diagnostic memory<br>Configuration support GSDML file<br>Parameterisation • System parameters<br>• Diagnostic behaviour<br>• Signal setup<br>• Fail-safe response<br>• Forcing of channels<br>Additional functions • Start-up parameterisation in plain text via fieldbus<br>• Fast start-up (FSU)<br>• Channel-oriented diagnostics via fieldbus<br>• Acyclic data access via fieldbus and via Ethernet<br>• System status can be displayed using process data<br>• Additional diagnostic interface for operator unit<br>• I&M<br>• LLDP<br>• MRP<br>• MRPD<br>• MQTT<br>• PROFIsafe<br>• PROFIenergy<br>• S2 system redundancy<br>Control elements DIL switch<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Intrinsic current consumption at nominal operating voltage [mA] Typically 145<br>Certification RCM<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] – 5... +50<br>Storage/transport [°C] –20 ... +70<br>Housing material Die-cast aluminium<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 80<br>Product weight [g] 280<br>**----- End of picture text -----**<br>
## - **Note** H-
Please observe the general limits and guidelines for the system when configuring the electrical modules.
## - **Note** H-
Always use the correct screws for the interlinking block; this depends on whether the block is made of metal or plastic:
• Self-tapping screws for plastic in• Screws with metric thread for metterlinking blocks al interlinking blocks
Subject to change – 2023/10
98
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – PROFINET bus node, push-pull SCRJ
## **Connection and display components**
|1|2<br>3<br>[1] Bus-specifc status LEDs<br>[2] CPX-specifc status LEDs<br>[3] Fieldbus interface (SCRJ socket,<br>2-pin)<br>[4] DIL switch|
|---|---|
|4<br>3||
|**Pin allocation for the feldbus interface**<br>Terminal allocation|**Pin allocation for the feldbus interface**<br>Terminal allocation|Pin<br>Signal<br>Designation|Pin<br>Signal<br>Designation|Pin<br>Signal<br>Designation|
|---|---|---|---|---|
|**SCRJ socket**|||||
|||1<br>2|TX|Outgoing|
||||Rx|Incoming|
2023/10 – Subject to change
99
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – PROFINET bus node, push-pull SCRJ
**==> picture [524 x 430] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>Bus node<br>2x SCRJ push-pull socket, AIDA • I&M 8110371 CPX-M-FB45<br>• LLDP<br>• MRP<br>• MRPD<br>• PROFIenergy<br>• S2 system redundancy<br>Bus connection<br>SCRJ plug, 2-pin, push-pull 571017 FBS-SCRJ-PP-GS<br>Cover cap for bus connection 548753 CPX-M-AK-C<br>Cover cap for bus connection 2873540 CPX-M-AK-D<br>Cover for DIL switch 548754 CPX-M-AK-M<br>Screws for attaching an inscription label to the bus node (12 pieces) 550222 CPX-M-M2.5X8-12X<br>5-pin M12 to mini USB socket adapter and controller software 547432 NEFC-M12G5-0.3-U1G5<br>User documentation<br>Electronics manual, CPX bus node German 548759 CPX-(M)-FB33_35/43_45-DE<br>English 548760 CPX-(M)-FB33_35/43_45-EN<br>Spanish 548761 CPX-(M)-FB33_35/43_45-ES<br>French 548762 CPX-(M)-FB33_35/43_45-FR<br>Italian 548763 CPX-(M)-FB33_35/43_45-IT<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
100
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – EtherNet/IP bus node
• Industrial Ethernet Bus node for handling communication • EtherNet/IP between the electrical terminal CPX • Web interface and the Ethernet/IP network. The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules. The status of the CPX terminal is displayed as a common message via 4 CPX-specific LEDs. **Application** Bus connection The bus connection is established via EtherNet/IP is an open bus system an M12 plug, D-coded to IEC 947-5-2 based on the Ethernet standard and with degree of protection IP65, IP67. TCP/IP technology (IEEE802.3). EtherNet/IP implementation The CPX-FB36 supports the two operatrectly controlled by the Ethernet/IP ing modes: remote I/O and remote master (host). controller. In addition to activation via a bus sysIn remote I/O operating mode, all functem, it is possible to use IT technolotions of the CPX valve terminal are digies. An integrated web server enables diagnostic data to be visualised via
## Points to note in connection with CPX-CEC
When a bus node is combined with a In this case, the bus node only procontrol block (CPX-CEC, in the fieldbus vides the communication interface to remote controller operating mode), the the PLC. connected I/Os and/or valves, sensors Communication between the control and actuators are controlled via the block and CPX bus node takes place by CPX control block. interlinking the CPX modules and takes
forms to DIN EN 50173/CAT 5 as an integrated interface.
HTML. Various programs support direct access to the device data from the automation network.
The Ethernet/IP node for CPX supports the transmission technology that conup the following address capacity in • 56 byte inputs the CPX system: • 56 byte outputs • 8 byte outputs
• 8 byte inputs The following address capacity remains in the control block or CPX system for activating the peripherals:
2023/10 – Subject to change
101
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – EtherNet/IP bus node
## **General technical data**
**==> picture [524 x 467] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type CPX-FB36<br>Fieldbus interface 2x M12x1 socket, 4-pin, D-coded<br>Baud rate [Mbps] 10/100<br>Protocol EtherNet/IP<br>Modbus TCP<br>Max. address capacity, inputs [byte] 64<br>Max. address volume for outputs [byte] 64<br>LED displays (bus-specific) MS = Module status<br>NS = network status<br>TP1 = Network active port 1<br>TP2 = Network active port 2<br>Device-specific diagnostics • Module and channel-oriented diagnostics<br>• Undervoltage of modules<br>• Diagnostic memory<br>Configuration support • EDS file<br>• L5K export with CPX-FMT<br>Parameterisation • Diagnostic behaviour<br>• Fail-safe response<br>• Forcing of channels<br>• Idle mode characteristics<br>• Signal setup<br>• System parameters<br>Additional functions • EtherNet/IP Quickconnect<br>• Ring topology (DLR)<br>• Acyclic data access via "Explicit Message" and Ethernet<br>• Integrated switch<br>• IP addressing via DHCP, DIL switch or operator unit<br>• Channel-oriented diagnostics via fieldbus<br>• Start-up parameterisation in plain text via fieldbus<br>• System status can be displayed using process data<br>• Additional diagnostic interface for operator units<br>Control elements DIL switch<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Current consumption at nominal voltage [mA] Typically 100<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] – 5... +50<br>Storage/transport [°C] –20 ... +70<br>Materials PA-reinforced<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 125<br>**----- End of picture text -----**<br>
## - **Note** H-
Please observe the general limits and guidelines for the system when configuring the electrical modules.
Subject to change – 2023/10
102
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – EtherNet/IP bus node
## **Connection and display components**
|1|||2|
|---|---|---|---|
|4|||3|
||||3|
|||||
|||||
- [1] Bus-specific status LEDs [2] CPX-specific status LEDs
- [3] Fieldbus interface (M12 socket, 4-pin, D-coded)
- [4] Transparent DIL switch cover
|**Pin allocation for the feldbus interface**<br>Terminal allocation|Pin<br>Signal<br>Designation|Pin<br>Signal<br>Designation|Pin<br>Signal<br>Designation|
|---|---|---|---|
|**Socket, M12, D-coded**||||
||1<br>2<br>3<br>4<br>Housing|TD+|Transmitted data+|
|||RD+|Received data+|
|||TD-|Transmitted data-|
|||RD-|Received data-|
|||FE|Shielding|
2023/10 – Subject to change
103
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – EtherNet/IP bus node
**==> picture [524 x 482] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>Bus node<br>EtherNet/IP bus node 1912451 CPX-FB36<br>Bus connection<br>Plug M12x1, 4-pin, D-coded 543109 NECU-M-S-D12G4-C2-ET<br>Connecting cable, Straight plug, M12x1, 0.5 m 8040446 NEBC-D12G4-ES-0.5-S-D12G4-ET<br>straight plug, M12x1, 4-pin, D-coded 1 m 8040447 NEBC-D12G4-ES-1-S-D12G4-ET<br>4-pin, D-coded 3 m 8040448 NEBC-D12G4-ES-3-S-D12G4-ET<br>5 m 8040449 NEBC-D12G4-ES-5-S-D12G4-ET<br>10 m 8040450 NEBC-D12G4-ES-10-S-D12G4-ET<br>Straight plug, RJ45, 8-pin 1 m 8040451 NEBC-D12G4-ES-1-S-R3G4-ET<br>3 m 8040452 NEBC-D12G4-ES-3-S-R3G4-ET<br>5 m 8040453 NEBC-D12G4-ES-5-S-R3G4-ET<br>10 m 8040454 NEBC-D12G4-ES-10-S-R3G4-ET<br>Open end, 4-wire 5 m 8040456 NEBC-LE4-ES-5-D12G4-ET<br>Inspection cover, transparent 533334 AK-SUB-9/15-B<br>Inscription label holder for connection block 536593 CPX-ST-1<br>5-pin M12 to mini USB socket adapter and controller software 547432 NEFC-M12G5-0.3-U1G5<br>User documentation<br>User documentation for bus node CPX-FB36 German 8024074 CPX-FB36-DE<br>English 8024075 CPX-FB36-EN<br>Spanish 8024076 CPX-FB36-ES<br>French 8024077 CPX-FB36-FR<br>Italian 8024078 CPX-FB36-IT<br>Chinese 8024079 CPX-FB36-ZH<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
104
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – EtherCAT bus node
Bus node for operating the CPX valve terminal on EtherCAT.
The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules.
The status of the CPX terminal is displayed as a common message via 4 CPX-specific LEDs. The fieldbus communication status is displayed via 4 bus-specific LEDs.
## **Application**
## Bus connection
The bus connection is established via Both connections are equivalent two sockets M12x1, D-coded to 100BaseTX Ethernet ports with inteIEC 61076-2-101 with degree of prograted auto MDI functionality (crossotection IP65, IP67. ver and patch cable can be used) that are brought together via an internal switch.
- Maximum segment length 100 m
- Transmission rate 100 Mbps
## EtherCAT implementation
The CPX-FB37 supports the EtherCAT protocol on the basis of the Ethernet standard and TCP/IP technology to IEEE802.3.
This guarantees a data exchange with a high data transmission rate, for example I/O data from sensors, actuators or robot controllers, PLCs or process equipment. In addition, non-real-time critical information such as diagnostic information, configuration information, etc. can be transferred.
The data bandwidth is sufficient to transfer both data types (real-time and non-real-time) in parallel.
The bus node features LEDs for bus status and CPX peripheral information as well as switch elements and a diagnostic interface. The bus node can be used as a remote I/O or remote controller. All information relevant to the CPX can be read out and, dependent on the function, changed via CPX-FMT. The functions MDP (modular device profile) and CoE (CAN over EtherCAT) enable easy access to parameters and diagnostic data via EtherCAT.
Specific EtherCAT functions:
- CoE (parameters and diagnostics or • DC (distributed clocks), fail-safe mode): all module parametime-synchronised data ters can be set transmission
- FoE (file over EtherCAT) makes it possible to download firmware easily
- EoE (Ethernet over EtherCAT): diagnostic data can be retrieved easily using a browser
- MDP (modular device profile): easy configuration using a module selection box
- Hot Connect, easy replacement of an EtherCAT CPX terminal
## Points to note in connection with CPX-CEC
When a bus node is combined with a control block (CPX-CEC, in the fieldbus remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX control block.
In this case, the bus node only provides the communication interface to the PLC.
Communication between the control block and CPX bus node takes place by interlinking the CPX modules and takes
up the following address capacity in • 56/48 byte inputs the CPX system: • 56/48 byte outputs
- 56/48 byte outputs
- 8/16 byte outputs
- 8/16 byte inputs
The following address capacity remains in the control block or CPX system for activating the peripherals:
2023/10 – Subject to change
105
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – EtherCAT bus node
## **General technical data**
**==> picture [524 x 475] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type CPX-FB37<br>Fieldbus interface 2x M12x1 socket, 4-pin, D-coded<br>Baud rate [Mbps] 100<br>Protocol EtherCAT<br>Max. address capacity Inputs [byte] 64<br>Outputs [byte] 64<br>LED displays Bus-specific Error = Communication error<br>L/A1 = Network active port 1<br>L/A2 = Network active port 2<br>Run = Communication status<br>Product-specific M = Modify, parameterisation<br>PL = Load supply<br>PS = Electronic supply, sensor supply<br>SF = System fault<br>Device-specific diagnostics • Channel and module-oriented diagnostics<br>• Undervoltage of modules<br>• Diagnostic memory<br>Configuration support ESI file<br>Parameterisation • System parameters<br>• Diagnostic behaviour<br>• Signal setup<br>• Fail-safe response<br>• Forcing of channels<br>Additional functions • System status can be displayed using process data<br>• Additional diagnostic interface for operator units<br>• Emergency message<br>• Acyclic data access via fieldbus<br>• Diagnostics object<br>• Compatibility mode with CPX-FB38<br>• Modular device profile (MDP)<br>• Variable PDO mapping<br>Control elements DIL switch<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Current consumption [mA] Typically 100<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] – 5... +50<br>Storage/transport [°C] –20 ... +70<br>Materials Housing PA-reinforced<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 125<br>**----- End of picture text -----**<br>
- **Note** - **Note** H- H- Please observe the general limits Always use the correct screws for the • Self-tapping screws for plastic in• Screws with metric thread for metand guidelines for the system when interlinking block; this depends on terlinking blocks al interlinking blocks configuring the electrical modules. whether the block is made of metal or plastic:
Subject to change – 2023/10
106
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – EtherCAT bus node
## **Connection and display components**
|1|2<br>3<br>4|
|---|---|
|5||
- [1] Bus-specific status LEDs
- [2] CPX-specific status LEDs
- [3] Fieldbus interface, input (socket M12x1, 4-pin, D-coded)
- [4] Fieldbus interface, output (socket M12x1, 4-pin, D-coded)
- [5] DIL switch
|**Pin allocation for the feldbus interface**<br>Terminal allocation|Pin<br>Signal<br>Designation|Pin<br>Signal<br>Designation|Pin<br>Signal<br>Designation|
|---|---|---|---|
|**M12x1 socket, D-coded**||||
||1<br>2<br>3<br>4<br>Housing|TD+|Transmitted data+|
|||RD+|Received data+|
|||TD-|Transmitted data-|
|||RD-|Received data-|
|||FE|Shielding|
2023/10 – Subject to change
107
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – EtherCAT bus node
**==> picture [524 x 502] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>Bus node<br>EtherCAT bus node 2735960 CPX-FB37<br>Bus connection<br>Plug M12x1, 4-pin, D-coded 543109 NECU-M-S-D12G4-C2-ET<br>Connecting cable, Straight plug, M12x1, 0.5 m 8040446 NEBC-D12G4-ES-0.5-S-D12G4-ET<br>straight plug, M12x1, 4-pin, D-coded 1 m 8040447 NEBC-D12G4-ES-1-S-D12G4-ET<br>4-pin, D-coded 3 m 8040448 NEBC-D12G4-ES-3-S-D12G4-ET<br>5 m 8040449 NEBC-D12G4-ES-5-S-D12G4-ET<br>10 m 8040450 NEBC-D12G4-ES-10-S-D12G4-ET<br>Straight plug, RJ45, 8-pin 1 m 8040451 NEBC-D12G4-ES-1-S-R3G4-ET<br>3 m 8040452 NEBC-D12G4-ES-3-S-R3G4-ET<br>5 m 8040453 NEBC-D12G4-ES-5-S-R3G4-ET<br>10 m 8040454 NEBC-D12G4-ES-10-S-R3G4-ET<br>Open end, 4-wire 5 m 8040456 NEBC-LE4-ES-5-D12G4-ET<br>Inspection cover, transparent 533334 AK-SUB-9/15-B<br>Cover cap for sealing unused bus connections (10 pieces) 165592 ISK-M12<br>Inscription label holder for connection block 536593 CPX-ST-1<br>5-pin M12 to mini USB socket adapter and controller software 547432 NEFC-M12G5-0.3-U1G5<br>User documentation<br>Electronics manual, CPX bus node, type CPX-FB37 German 8029674 P.BE-CPX-FB37-DE<br>English 8029675 P.BE-CPX-FB37-EN<br>Spanish 8029676 P.BE-CPX-FB37-ES<br>French 8029677 P.BE-CPX-FB37-FR<br>Italian 8029678 P.BE-CPX-FB37-IT<br>Chinese 8029679 P.BE-CPX-FB37-ZH<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
108
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Sercos III bus node
- Sercos
- Web interface
Bus node for handling communication between the electrical terminal CPX and the Sercos III network. The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules.
The status of the CPX terminal is displayed as a common message via 4 CPX-specific LEDs.
## **Application**
## Bus connection
The bus connection is established via two M12x1 plugs, D-coded to IEC 9475-2 with degree of protection to IP65, IP67. The connections are equipped with automatic detection for the incoming and outgoing connection.
The Sercos III bus node can be used to connect the CPX valve terminal to the standardised Sercos III bus. Sercos III uses the Ethernet standard (IEEE802.3) and TCP/IP technology for communication in an industrial environment.
Industry-compatible Sercos III devices enable data to be exchanged with a higher data transmission rate, such as data from sensors, actuators or controllers.
Non-real-time critical information, such as diagnostics or configuration information, can also be transferred.
## Web servers
In addition to activation via a bus system, it is possible to use IT technologies. An integrated web server enables
diagnostic data to be visualised via HTML. Various programs support direct
access to the device data from the automation network.
## Points to note in connection with CPX-CEC
The CPX-FB39 supports the operating modes remote I/O and remote controller.
In remote I/O operating mode, all functions of the CPX valve terminal are directly controlled by the Sercos controller. When a bus node is combined with a control block (CPX-CEC, in the fieldbus
remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX control block.
In this case, the bus node only provides the communication interface to the PLC. Communication between the control block and CPX bus node takes place by
interlinking the CPX modules and takes • 56/48 byte outputs up the following address capacity in the CPX system:
- 8/16 byte outputs
- 8/16 byte inputs
The following address capacity remains in the control block or CPX system for activating the peripherals: • 56/48 byte inputs
2023/10 – Subject to change
109
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Sercos III bus node
## **General technical data**
**==> picture [524 x 454] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type CPX-FB39<br>Fieldbus interface 2x M12x1 socket, D-coded, 4-pin<br>Baud rate [Mbps] 100 full/half duplex<br>Protocol Sercos III<br>Max. address capacity Inputs [byte] 64<br>Outputs [byte] 64<br>LED displays Bus-specific S = Sercos LED<br>SD = Sercos sub-device LED<br>TP1 = Network active port 1<br>TP2 = Network active port 2<br>Product-specific M = Modify, parameterisation<br>PL = Load supply<br>PS = Electronics supply, sensor supply<br>SF = System fault<br>Device-specific diagnostics • Module and channel-oriented diagnostics<br>• Undervoltage of modules<br>• Diagnostic memory<br>Configuration support SDDML file<br>Parameterisation • Diagnostic behaviour<br>• Fallback output data<br>• Forcing of channels<br>• Signal setup<br>• System parameters<br>Additional functions • Acyclic and cyclic data access via Sercos<br>• IP addressing via Sercos parameters or operator unit<br>• Channel-oriented diagnostics via fieldbus<br>• Start-up parameterisation in plain text via fieldbus<br>• System status can be displayed using process data<br>• Additional diagnostic interface for operator units<br>Control elements DIL switch<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Current consumption at nominal voltage [mA] Typically 100<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] – 5... +50<br>Storage/transport [°C] –20 ... +70<br>Materials PA-reinforced<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 125<br>**----- End of picture text -----**<br>
## - **Note** H-
Please observe the general limits and guidelines for the system when configuring the electrical modules.
Subject to change – 2023/10
110
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Sercos III bus node
## **Connection and display components**
**==> picture [69 x 68] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>2<br>**----- End of picture text -----**<br>
**==> picture [69 x 85] intentionally omitted <==**
**----- Start of picture text -----**<br>
3<br>4<br>4<br>**----- End of picture text -----**<br>
- [1] Service interface for PC with CPX maintenance tool NEFC-M12G5-
- 0.3-U1G5
- [2] Transparent DIL switch cover
- [3] Status LED, bus-specific and CPX-specific
- [4] Fieldbus interface (M12x1 socket,
- 4-pin, D-coded)
## **Pin allocation for the fieldbus interface**
**==> picture [523 x 127] intentionally omitted <==**
**----- Start of picture text -----**<br>
Terminal allocation Pin Signal Designation<br>M12x1 socket, D-coded<br>1 TD+ Transmitted data+<br>2 RD+ Received data+ -H- Note<br>3 TD- Transmitted data- The CPX-FB39 can automatically<br>4 RD- Received data-<br>detect transmitter and receiver ca-<br>Housing FE Shielding<br>bles (auto-MDI/MDI-X auto-crosso-<br>ver).<br>RD and TD signal pairs are auto-<br>matically swapped if required.<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
111
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Sercos III bus node
**==> picture [524 x 502] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>Bus node<br>Ethernet Sercos III bus node 2093101 CPX-FB39<br>Bus connection<br>Plug M12x1, 4-pin, D-coded 543109 NECU-M-S-D12G4-C2-ET<br>Connecting cable, Straight plug, M12x1, 0.5 m 8040446 NEBC-D12G4-ES-0.5-S-D12G4-ET<br>straight plug, M12x1, 4-pin, D-coded 1 m 8040447 NEBC-D12G4-ES-1-S-D12G4-ET<br>4-pin, D-coded 3 m 8040448 NEBC-D12G4-ES-3-S-D12G4-ET<br>5 m 8040449 NEBC-D12G4-ES-5-S-D12G4-ET<br>10 m 8040450 NEBC-D12G4-ES-10-S-D12G4-ET<br>Straight plug, RJ45, 8-pin 1 m 8040451 NEBC-D12G4-ES-1-S-R3G4-ET<br>3 m 8040452 NEBC-D12G4-ES-3-S-R3G4-ET<br>5 m 8040453 NEBC-D12G4-ES-5-S-R3G4-ET<br>10 m 8040454 NEBC-D12G4-ES-10-S-R3G4-ET<br>Open end, 4-wire 5 m 8040456 NEBC-LE4-ES-5-D12G4-ET<br>Inspection cover, transparent 533334 AK-SUB-9/15-B<br>Cover cap for sealing unused bus connections (10 pieces) 165592 ISK-M12<br>Inscription label holder for connection block 536593 CPX-ST-1<br>5-pin M12 to mini USB socket adapter and controller software 547432 NEFC-M12G5-0.3-U1G5<br>User documentation<br>User documentation for bus node CPX-FB39 German 8028632 P.BE-CPX-FB39-DE<br>English 8028633 P.BE-CPX-FB39-EN<br>Spanish 8028634 P.BE-CPX-FB39-ES<br>French 8028635 P.BE-CPX-FB39-FR<br>Italian 8028636 P.BE-CPX-FB39-IT<br>Chinese 8028637 P.BE-CPX-FB39-ZH<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
112
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – POWERLINK bus node
- Ethernet POWERLINK
- Web interface
Bus node for handling communication between the electrical terminal CPX and the Ethernet POWERLINK network. The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules.
The status of the CPX terminal is displayed as a common message via 4 CPX-specific LEDs.
## **Application**
## Bus connection
The bus connection is established via It includes all the key features of an M12x1 plug, D-coded to IEC 947-5standard Ethernet, including internode 2 with degree of protection IP65, IP67. communication, hotplug capability and Ethernet POWERLINK uses the Ethernet free selection of network topology. standards and TCP/IP technology Ethernet POWERLINK fulfils the re(IEEE802.3) for communication in an al-time requirements using a mix of industrial environment and integrates timeslot and polling procedures. In all CANopen mechanisms. other words, defined times are re-
served on the Ethernet cable exclusively for transferring real-time data. Only network participants which have previously been prompted by the controller are able to transmit data during these timeslots.
## Ethernet POWERLINK implementation
The CPX-FB40 supports the two operating modes: remote I/O and remote controller.
In remote I/O operating mode, all functions of the CPX valve terminal are di-
rectly controlled by the Ethernet POWERLINK master (host). In addition to activation via a bus system, it is possible to use IT technologies. An integrated web server enables diagnostic data to be visualised via
HTML. Various programs support direct access to the device data from the automation network.
The Ethernet POWERLINK node for CPX supports the transmission technology
that conforms to DIN EN 50173/CAT 5 as an integrated interface.
## Points to note in connection with CPX-CEC
When a bus node is combined with a control block (CPX-CEC, in the fieldbus remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX control block.
In this case, the bus node only provides the communication interface to the PLC.
Communication between the control block and CPX bus node takes place by interlinking the CPX modules and takes
up the following address capacity in the CPX system: • 8 byte outputs • 8 byte inputs The following address capacity remains in the control block or CPX system for activating the peripherals:
- 56 byte inputs • 56 byte outputs
2023/10 – Subject to change
113
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – POWERLINK bus node
## **General technical data**
**==> picture [524 x 484] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type CPX-FB40<br>Fieldbus interface 2x M12x1 socket, D-coded, 4-pin<br>Baud rate [Mbps] 100<br>Protocol Ethernet PowerLink V2<br>Max. address capacity Inputs [byte] 64<br>Outputs [byte] 64<br>LED displays Bus-specific BE = POWERLINK error<br>BS = POWERLINK status<br>L/A1 = Link/activity port 1<br>L/A2 = Link/activity port 2<br>Product-specific M = Modify, parameterisation<br>PL = Load supply<br>PS = Electronic supply, sensor supply<br>SF = System fault<br>Device-specific diagnostics • Module and channel-oriented diagnostics<br>• Undervoltage of modules<br>• Diagnostic memory<br>Configuration support • XDC file<br>• XDD file<br>Parameterisation • Diagnostic behaviour<br>• Fail-safe response<br>• Forcing of channels<br>• Signal setup<br>• System parameters<br>Additional functions • Acyclic data access via "SDO" and Ethernet<br>• Integrated hub<br>• IP addressing via DHCP, DIL switch or operator unit<br>• Channel-oriented diagnostics via fieldbus<br>• Start-up parameterisation in plain text via fieldbus<br>• System status can be displayed using process data<br>• Additional diagnostic interface for operator units<br>Control elements DIL switch<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Reverse polarity protection For operating voltage<br>Current consumption at nominal voltage [mA] Typically 100<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] – 5... +50<br>Storage/transport [°C] –20 ... +70<br>Materials PA-reinforced<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 125<br>**----- End of picture text -----**<br>
## - **Note** H-
Please observe the general limits and guidelines for the system when configuring the electrical modules.
Subject to change – 2023/10
d **Internet: www.festo.com/catalogue/...**
114
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – POWERLINK bus node
## **Connection and display components**
|1|2<br>3<br>3|
|---|---|
|4||
- [1] Bus-specific status LEDs [2] CPX-specific status LEDs
- [3] Fieldbus interface (M12x1 socket, 4-pin, D-coded)
- [4] Transparent DIL switch cover
|**Pin allocation for the feldbus interface**<br>Terminal allocation|Pin<br>Signal<br>Designation|Pin<br>Signal<br>Designation|Pin<br>Signal<br>Designation|
|---|---|---|---|
|**M12x1 socket, D-coded**||||
||1<br>2<br>3<br>4<br>Housing|TD+|Transmitted data+|
|||RD+|Received data+|
|||TD-|Transmitted data-|
|||RD-|Received data-|
|||FE|Shielding|
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
115
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – POWERLINK bus node
**==> picture [524 x 481] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>Bus node<br>Ethernet POWERLINK bus node 2474896 CPX-FB40<br>Bus connection<br>Plug M12x1, 4-pin, D-coded 543109 NECU-M-S-D12G4-C2-ET<br>Connecting cable, Straight plug, M12x1, 0.5 m 8040446 NEBC-D12G4-ES-0.5-S-D12G4-ET<br>straight plug, M12x1, 4-pin, D-coded 1 m 8040447 NEBC-D12G4-ES-1-S-D12G4-ET<br>4-pin, D-coded 3 m 8040448 NEBC-D12G4-ES-3-S-D12G4-ET<br>5 m 8040449 NEBC-D12G4-ES-5-S-D12G4-ET<br>10 m 8040450 NEBC-D12G4-ES-10-S-D12G4-ET<br>Straight plug, RJ45, 8-pin 1 m 8040451 NEBC-D12G4-ES-1-S-R3G4-ET<br>3 m 8040452 NEBC-D12G4-ES-3-S-R3G4-ET<br>5 m 8040453 NEBC-D12G4-ES-5-S-R3G4-ET<br>10 m 8040454 NEBC-D12G4-ES-10-S-R3G4-ET<br>Open end, 4-wire 5 m 8040456 NEBC-LE4-ES-5-D12G4-ET<br>Inspection cover, transparent 533334 AK-SUB-9/15-B<br>Inscription label holder for connection block 536593 CPX-ST-1<br>5-pin M12 to mini USB socket adapter and controller software 547432 NEFC-M12G5-0.3-U1G5<br>User documentation<br>User documentation for bus node CPX-FB40 German 8028650 P.BE-CPX-FB40-DE<br>English 8028651 P.BE-CPX-FB40-EN<br>Spanish 8028652 P.BE-CPX-FB40-ES<br>French 8028653 P.BE-CPX-FB40-FR<br>Italian 8028654 P.BE-CPX-FB40-IT<br>Chinese 8028655 P.BE-CPX-FB40-ZH<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
116
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Interface for CPI system
The electrical interface CPX-CP establishes the connection to CP modules of the installation system CPI via pre-assembled connecting cables. The I/O data of the connected valve terminals with CP string extension and CP input and output modules are transferred to the connected CPX bus node and thus via fieldbus to the higher-order controller.
This enables modular centralised and compact decentralised concepts to be established with one system.
## **Application**
## CP connection
As well as transmitting the communication data, the max. 4 CP strings of a CPX-CP interface also transmit the power supply to the connected sensors and the load supply to the valves (or outputs). Both circuits are supplied separately with 24 V but using a common reference potential.
The valve terminals with CP string extension (or outputs) are supplied with voltage for the electronics and valves by the interlinking block.
The CP interface allows the following combinations:
- The CP interface allows the following • Decentralised digital inputs and combinations: outputs of the CP installation sys• Centralised analogue and digital intem puts and outputs of the CPX termi• Valve/valve terminals that can be nal connected both centrally and decentrally
## **Configuration example – CP interface with CP modules**
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
117
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Interface for CPI system
## **Implementation**
The CPX-CP interface supports the CPI system:
- Max. 4 individual electronically protected CP strings
- Max. 4 CP modules per string
- Max. 32 inputs/32 outputs per string
- The maximum length of a string is 10 m. If the CP interface is positioned centrally, the CP system can cover an area of 20 m in diameter.
The following CP module variants are available:
- Input modules with 8 or 16 digital inputs (connection technology M8, M12 and CageClamp)
- Output modules with 4 or 8 digital outputs (connection technology M12)
- Valve terminals with CP string extension (up to 32 solenoid coils, different valve functions)
CPI modules support the following functions:
Several CP interface modules can be combined in one CPX terminal, depending on the address capacity of the bus node.
- Module-oriented diagnostics
- Module/channel-oriented parameterisation
Example:
- CPX-FB13 (512 I/O)
- Support of all functions by the CPX-FMT
- CPX-FMT • Max. 4 CP interface modules
- • Module can be positioned anywhere (128 I/O each) possible within the string
- Modules with CPI functionality
## - **Note** H-
When arranging the CP modules it should be taken into consideration that CP input modules without CPI functionality should always be placed at the end of a string.
## **Configuration**
- The following rules apply for a string of • Maximum extension: The configuration of the strings with a CPX-CP interface: • 4 input modules and 4 valve termirespect to the module type and posi• Max. one output module or one nals/output modules without CPI tion of the modules in the string is envalve terminal without CPI functionfunctionality tered by activating the SAVE key in the ality • 16 CP modules with CPI CPX-CP interface and saved there re-
- • Max. one output module without CPI functionality manently. functionality or one valve terminal Saved data are retained even when the with CP string extension CP interface is isolated from the power
- • Any number of CP modules with CPI supply.
- Any number of CP modules with CPI functionality, up to the maximum limit of 4 modules and/or 32 inputs/32 outputs per string
The representation of the CP interface within a CPX terminal and thus at the fieldbus is dependent on the characteristics of the relevant fieldbus system. In addition to input and output addressing, this also applies to the representation of the diagnostics and parameterisation of the CP module and the characteristics of the CPI system.
## - **Note** H-
The remanent saving of configuration data means that changes in the configuration or faulty modules are still displayed even after a voltage failure.
Subject to change – 2023/10
118
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Interface for CPI system
## **General technical data**
**==> picture [523 x 332] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type CPX-CP-4-FB<br>Brief description CP interface<br>Max. number of CP strings 4<br>CP modules per string 4<br>Outputs per string 32<br>Inputs per string 32<br>CP connection Socket M9, 5-pin<br>Baud rate [kbps] 1000<br>Cycle time CP modules without CPI functionality [ms] 4<br>CP modules with CPI functionality [ms] 2<br>LED displays L1 ... 4= Status of the CP string 1 ... 4<br>PS = Electronics supply, sensor supply<br>PL = Load supply<br>RN = Status of the CP system<br>SF = System fault<br>Device-specific diagnostics Via bus node<br>Operating voltage Nominal value [V DC] 24 (reverse polarity protected)<br>Permissible range [V DC] 18 ... 30<br>Power failure buffering [ms] 20<br>Sensor supply voltage [V DC] 24 ±25% coming from bus node<br>Actuator load voltage [V DC] 24 ±10% coming from bus node<br>Current consumption Without CP modules [A] Max. 0.2<br>Per CP string [A] Max. 1.6<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Materials PA<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 45<br>Product weight [g] 139<br>**----- End of picture text -----**<br>
## - **Note** H-
Please observe the general limits and guidelines for the system when configuring the electrical modules.
2023/10 – Subject to change
119
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Interface for CPI system
## **Connection and display components**
**==> picture [344 x 179] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 [1] CP string LEDs<br>[2] SAVE key<br>4 [3] Holders for inscription labels<br>2<br>(IBS 6x10)<br>[4] CPX-specific status LEDs<br>3 5 [5] CP connections for up to 4 strings<br>(0 ... 3)<br>3 5<br>3 5<br>3 5<br>3<br>**----- End of picture text -----**<br>
## **Power supply**
**==> picture [126 x 143] intentionally omitted <==**
The module combines the 0 V potential of the power supply for electronics and sensors with the 0 V potential of the power supply for valves.
If all pins of the valves of a pneumatic interface connected to the right of the CP interface are to be switched off, an appropriate interlinking block with additional supply for valves must be used to the right of the CP interface.
Subject to change – 2023/10
120
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Interface for CPI system
**==> picture [523 x 342] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>CP interface<br>Interface for max. 16 I/O modules and valve terminals of the CPI system 526705 CPX-CP-4-FB<br>Bus connection<br>Cover cap M12 165592 ISK-M12<br>Connecting cable, angled plug, angled socket 0.25 m 540327 KVI-CP-3-WS-WD-0.25<br>0.5 m 540328 KVI-CP-3-WS-WD-0.5<br>2 m 540329 KVI-CP-3-WS-WD-2<br>5 m 540330 KVI-CP-3-WS-WD-5<br>8 m 540331 KVI-CP-3-WS-WD-8<br>Connecting cable, straight plug, straight socket 2 m 540332 KVI-CP-3-GS-GD-2<br>5 m 540333 KVI-CP-3-GS-GD-5<br>8 m 540334 KVI-CP-3-GS-GD-8<br>Inscription label holder for connection block 536593 CPX-ST-1<br>User documentation<br>User documentation for CPX-CP interface German 539293 P.BE-CPX-CP-EN<br>English 539294 P.BE-CPX-CP-EN<br>Spanish 539295 P.BE-CPX-CP-ES<br>French 539296 P.BE-CPX-CP-FR<br>Italian 539297 P.BE-CPX-CP-IT<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
121
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – I-Port interface
**==> picture [60 x 118] intentionally omitted <==**
**----- Start of picture text -----**<br>
Application<br>I-Port interface<br>12/14 82/84<br>11 3/5<br>1<br>3G 3G 3G 3G 5J 5J 5J 5J<br>**----- End of picture text -----**<br>
As well as transmitting the communication data, the I-Port interfaces of a CPX CTEL master also transmit the power supply to the connected sensors and the load supply to the valves (or
The electrical interface CPX CTEL master establishes the connection to modules of the CTEL/CTEU series that have an I-Port interface (device). The I/O data from the connected devices are transmitted to the connected CPX bus node and thus to the higher-order controller via fieldbus. A maximum of 4 devices can be connected to a CPX CTEL master via corresponding M12 interfaces.
outputs). Both circuits are supplied separately with 24 V, using a separate reference potential. The connecting cables with a dual function as signal cable and supply ca-
ble must meet the corresponding increased requirements.
## **Configuration example – CPX CTEL master with CTEL modules**
**==> picture [51 x 29] intentionally omitted <==**
**----- Start of picture text -----**<br>
> & 2225!<br>8. | A<br>3G 3G 3G 3G 5J 5J 5J 5J<br>12/14 82/84<br>11 3/5<br>1<br>**----- End of picture text -----**<br>
The CPX CTEL master provides 4 external I-Port interfaces, each of which can be connected to a device. I-Port is an interface for exchanging serial data for connecting decentralised modules or valve terminals from Festo. The I-Port interface is based on IO-Link and is compatible with it in certain areas. The connection type corresponds to a star topology. In other words, only one module or valve terminal can be connected to each I-Port.
The limitations with respect to IO-Link include:
- Permanently set baud rate of 230.4 kbps
- SIO mode is not supported
- Max. 32 bytes of input data and 32 bytes of output data
- Only one dump of the master commands is used
- Configuration via IODD is not supported.
Subject to change – 2023/10
122
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – I-Port interface
## **Implementation**
The CPX CTEL master from Festo enaThe following device variants are availThe decentralised arrangement of the bles modules with an I-Port interface able: modules and valve terminals with to be connected to a CPX system: • Input modules with 16 digital inI-Port enables them to be mounted • Max. 4 devices with individual elecputs (connection technology M8 close to the cylinders and actuators or tronic protection 3-pin and M12 5-pin) sensors to be controlled. This means • Max. 64 inputs/64 outputs per • Valve terminals with I-Port interface that the compressed air supply lines I-Port interface (up to 48 solenoid coils, different and sensor connecting cables used • The maximum length of a string is valve functions) can be shortened, and it may be possi20 m. ble to use smaller valves, thereby saving costs.
Several CPX CTEL masters can be combined in one CPX terminal, depending on the address capacity of the bus node. Example:
- CPX-FB13 (512 I/O)
- A maximum of 2 CPX CTEL masters is possible (each with 256 I/O)
## **Configuration**
Settings Manual configuration The exact amount of the I/O bytes In the case of manual configuration The process image then always has the made available depends on the re(tool change mode), the volume of insame scope, regardless of the connectquirements of the connected devices puts and outputs in the process image ed devices. or of the correspondingly selected opof the CPX system or of the higher-orThe I/O length specified always applies erating mode. der fieldbus can be defined manually to all four I-Ports (max. 8 bytes per The operating mode or preset configuusing the DIL switches. I-Port).
The exact amount of the I/O bytes made available depends on the requirements of the connected devices or of the correspondingly selected operating mode.
The operating mode or preset configuration of the CPX CTEL master can be specified by the user. Selecting the operating mode and setting the manual configuration takes place via the DIL switches. These DIL switches are not required during continuous operation and are only accessible in the disassembled state.
## Automatic configuration
In the case of automatic configuration, the I/O length for each I-Port is determined individually and this value is used to select the appropriate or next highest configuration preset.
## **Power supply for I-Port devices**
- The CPX-CTEL master provides two sepThe power supply for the devices and arate power supplies for the connected the inputs is provided by the power devices: supply for the electronics and sensors • For operating the device and the inof the CPX terminal. puts connected to it The power supply for the outputs and
- • For the outputs and valves that are valves is provided by the power supply connected to the device for the valves of the CPX terminal.
The interlinking block with additional connected separately without disconsupply ensures a separate supply voltnecting the devices. age for the valves and outputs. This means it is possible to disconnect this supply voltage separately. The valves and outputs of the connected I-Port devices can therefore be dis-
2023/10 – Subject to change
123
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – I-Port interface
## **General technical data**
**==> picture [524 x 433] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type CPX-CTEL-4-M12-5POL<br>Protocol I-Port<br>Max. address capacity Outputs [bit] 256<br>Inputs [bit] 256<br>I-Port connection 4x socket M12, 5-pin, A-coded<br>Number of I-Port interfaces 4<br>Maximum cable length [m] 20<br>Internal cycle time [ms] 1 per 8 bits of user data<br>Galvanic isolation Channel – channel No<br>Channel – internal bus Yes, with intermediate supply<br>LED displays X1 ... 4 = Status of the I-Port interface 1 ... 4<br>PS = Electronic supply<br>PL = Load supply<br>-P- = Module error<br>Diagnostics • Communication error<br>• Module short circuit<br>• Module-oriented diagnostics<br>• Undervoltage<br>Parameterisation • Diagnostic behaviour<br>• Failsafe per channel<br>• Forcing per channel<br>• Idle mode per channel<br>• Module parameters<br>• Tool change mode<br>Additional functions Tool change mode<br>Control elements DIL switch<br>Operating voltage Nominal value [V DC] 24 (reverse polarity protected)<br>Permissible range [V DC] 18 ... 30<br>Power failure buffering [ms] 10<br>Intrinsic current consumption at nominal operating voltage [mA] Typically 65<br>Max. power supply per channel [A] 4x 1.6<br>Max. residual current of outputs per channel [A] 4x 1.6<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Materials Reinforced PA, PC<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 55<br>Product weight [g] 110<br>**----- End of picture text -----**<br>
## - **Note** H-
Please observe the general limits and guidelines for the system when configuring the electrical modules.
Subject to change – 2023/10
124
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – I-Port interface
## **Connection and display components**
**==> picture [336 x 155] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 [1] Status LEDs for I-Port interfaces<br>[2] CPX-specific status LEDs<br>2 [3] Holders for inscription labels<br>(IBS 6x10)<br>[4] I-Port interfaces for up to<br>3 4 devices<br>4<br>3<br>3<br>4<br>3<br>**----- End of picture text -----**<br>
## ~~3~~
## **Combinations of bus nodes/control blocks with interface CPX-CTEL**
**==> picture [523 x 319] intentionally omitted <==**
**----- Start of picture text -----**<br>
Bus node/control block Part no. Interface<br>CPX-CTEL-4-M12-5POL<br>CPX-CEC-C1 567347 h<br>CPX-CEC-C1-V3 3473128 h<br>CPX-CEC-M1-V3 3472765 h<br>CPX-CEC 567346 h<br>CPX-CEC-S1-V3 3472425 h<br>CPX-FB11 526172 h<br>CPX-FB13 195740 h<br>CPX-FB14 526174 h<br>CPX-FB23-24 526176 h<br>CPX-FB36 1912451 h<br>CPX-FB37 2735960 h<br>CPX-FB39 2093101 h<br>CPX-FB40 2474896 h<br>CPX-FB43 8110369 h<br>CPX-M-FB44 8110370 h<br>CPX-M-FB45 8110371 h<br>Pin allocation – I-Port interface<br>Terminal allocation Pin Signal Designation<br>1 24 VSEN 24 V DC supply voltage for electronics and inputs<br>2 24 VVAL 24 V DC load voltage supply for valves and outputs<br>3 0 VSEN 0 V DC supply voltage for electronics and sensors<br>4 C/Q I-Port Communication signal C/Q, data transmission line<br>5 0 VVALVES 0 V DC load voltage supply for valves and outputs<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
125
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – I-Port interface
**==> picture [523 x 304] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions Download CAD data a www.festo.com<br>Type B1 B2 B3 H1 L1<br>CPX-CTEL-4-M12-5POL 108.1 118.9 124.9 55.1 50<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
126
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – I-Port interface
**==> picture [523 x 370] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>CPX-CTEL master<br>Interface for a maximum of 4 I/O modules and valve terminals with I-Port interface (devices) 1577012 CPX-CTEL-4-M12-5POL<br>Bus connection<br>Cover cap M12 165592 ISK-M12<br>Connecting cable M12-M12, 5-pin Cable characteristic: 0.5 m 8003617 NEBU-M12G5-K-0.5-M12W5<br>• Straight socket standard 2 m 8003618 NEBU-M12G5-K-2-M12W5<br>• Angled plug<br>Connecting cable M12-M12, 5-pin Cable characteristic: 0.5 m 570733 NEBU-M12W5-K-0.5-M12W5<br>• Angled socket standard 2 m 570734 NEBU-M12W5-K-2-M12W5<br>• Angled plug<br>Connecting cable M12-M12, 5-pin Cable characteristic: suita- 5 m 574321 NEBU-M12G5-E-5-Q8N-M12G5<br>• Straight socket ble for use with energy 7.5 m 574322 NEBU-M12G5-E-7.5-Q8N-M12G5<br>• Straight plug chains 10 m 574323 NEBU-M12G5-E-10-Q8N-M12G5<br>Inscription label holder for connection block 536593 CPX-ST-1<br>User documentation<br>User documentation CPX CTEL master German 574600 P.BE-CPX-CTEL-DE<br>English 574601 P.BE-CPX-CTEL-EN<br>Spanish 574602 P.BE-CPX-CTEL-ES<br>French 574603 P.BE-CPX-CTEL-FR<br>Italian 574604 P.BE-CPX-CTEL-IT<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
127
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – IO-Link interface
The electrical interface CPX-CTEL-2-... enables the connection of modules with IO-Link interface (IO-Link device) to the CPX terminal. The I/O data from the connected devices are transmitted to the connected CPX bus node and thus to the higher-order controller via fieldbus.
A maximum of two IO-Link devices can be connected to an electrical interface CPX-CTEL-2-... via the corresponding M12 interfaces.
## **Application**
The communication system IO-Link is used to exchange serial data from decentralised function modules (devices) at the field level.
The electrical interface CPX-CTEL-2-... provides two external IO-Link interfac-
es, each of which can be connected to a device.
The connection type corresponds to a star topology, which means that only one device can be connected to each port.
The address space that the module makes available and assigns accordingly in the CPX system can be configured according to various presettings. Selecting the operating mode and setting the manual configuration takes place via the DIL switches.
These DIL switches are not required during continuous operation and are only accessible in the disassembled state.
## Restrictions
The interfaces (ports) of electrical interface CPX-CTEL-2-... support the connection of IO-Link devices with few limitations.
- The process data length of the inputs and outputs is limited to 16 bytes each per port
- The driver strength on the C/Q line • SIO mode is not supported is limited to 250 mA
## Power supply for devices
The electrical interface CPX-CTEL-2-... provides two separate power supplies for the connected devices:
- For operating the device and the inputs connected to it
- For the outputs and valves that are connected to the device
The power supply for the devices and the inputs is provided by the power
supply for the electronics and sensors of the CPX terminal.
The power supply for the outputs and valves is provided by the power supply for the valves of the CPX terminal. The interlinking block with additional supply ensures a separate supply voltage for the valves and outputs. This
means it is possible to disconnect this supply voltage separately.
The valves and outputs of the connected I-Port devices can therefore be disconnected separately without disconnecting the devices.
Subject to change – 2023/10
128
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – IO-Link interface
## **General technical data**
**==> picture [523 x 424] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type CPX-CTEL-2-M12-5POL-LK<br>Protocol IO-Link, master version V 1.0<br>Max. address capacity Outputs [bit] 256<br>Inputs [bit] 256<br>I-Port connection 2x socket M12, 5-pin, A-coded<br>Number of IO-Link interfaces 2<br>Maximum cable length [m] 20<br>Internal cycle time [ms] 1 per 8 bits of user data<br>Galvanic isolation Channel – channel No<br>Channel – internal bus Yes, with intermediate supply<br>LED displays X1 ... 2 = Status of the IO-Link interface 1 ... 2<br>PS = Electronic supply<br>PL = Load supply<br>-P- = Module error<br>Diagnostics • Communication error<br>• Module short circuit<br>• Module-oriented diagnostics<br>• Undervoltage<br>Parameterisation • Diagnostic behaviour<br>• Failsafe per channel<br>• Forcing per channel<br>• Idle mode per channel<br>• Module parameters<br>Additional functions –<br>Control elements DIL switch<br>Operating voltage Nominal value [V DC] 24 (reverse polarity protected)<br>Permissible range [V DC] 18 ... 30<br>Power failure buffering [ms] 10<br>Intrinsic current consumption at nominal operating voltage [mA] Typically 65<br>Max. power supply per channel [A] 2x 1.6<br>Max. residual current of outputs per channel [A] 2x 1.6<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Materials Reinforced PA, PC<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 55<br>Product weight [g] 110<br>**----- End of picture text -----**<br>
## - **Note** H-
Please observe the general limits and guidelines for the system when configuring the electrical modules.
2023/10 – Subject to change
129
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – IO-Link interface
## **Connection and display components**
**==> picture [168 x 176] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>2<br>4 5<br>4 5<br>3<br>**----- End of picture text -----**<br>
- [1] Status LEDs for I-Port interfaces [2] CPX-specific status LEDs [3] Holders for inscription labels (IBS 6x10)
- [4] IO-Link interfaces for up to 2 devices 3 3
- [5] Unused connections 3 3 3 3 3 3 ~~3~~
## **Combinations of bus nodes/control blocks with interface CPX-CTEL-2**
**==> picture [524 x 119] intentionally omitted <==**
**----- Start of picture text -----**<br>
Bus node/control block Part no. Interface<br>CPX-CTEL-2-M12-5POL-LK<br>CPX-CEC-C1-V3 3473128 h<br>CPX-CEC-M1-V3 3472765 h<br>CPX-CEC-S1-V3 3472425 h<br>CPX-FB36 1912451 h<br>CPX-FB39 2093101 h<br>CPX-FB43 8110369 h<br>CPX-M-FB44 8110370 h<br>CPX-M-FB45 8110371 h<br>**----- End of picture text -----**<br>
## **Pin allocation of IO-Link interface**
**==> picture [523 x 92] intentionally omitted <==**
**----- Start of picture text -----**<br>
Terminal allocation Pin Signal Designation<br>1 24 VSEN 24 V DC supply voltage for electronics and inputs<br>2 24 VVAL 24 V DC load voltage supply for valves and outputs<br>3 0 VSEN 0 V DC supply voltage for electronics and sensors<br>4 C/Q I-Port Communication signal C/Q, data transmission line<br>5 0 VVALVES 0 V DC load voltage supply for valves and outputs<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
130
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – IO-Link interface
**==> picture [523 x 303] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions Download CAD data a www.festo.com<br>Type B1 B2 B3 H1 L1<br>CPX-CTEL-2-M12-5POL-LK 108.1 118.9 124.9 55.1 50<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
131
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – IO-Link interface
## **Ordering data**
**==> picture [524 x 370] intentionally omitted <==**
**----- Start of picture text -----**<br>
Designation Part no. Type<br>CPX CTEL master, IO-Link<br>Interface for max. 2 I/O modules and valve terminals with IO-Link interface (devices) 2900543 CPX-CTEL-2-M12-5POL-LK<br>Bus connection<br>Cover cap M12 165592 ISK-M12<br>Connecting cable M12-M12, 5-pin Cable characteristic: 0.5 m 8003617 NEBU-M12G5-K-0.5-M12W5<br>• Straight socket standard 2 m 8003618 NEBU-M12G5-K-2-M12W5<br>• Angled plug<br>Connecting cable M12-M12, 5-pin Cable characteristic: 0.5 m 570733 NEBU-M12W5-K-0.5-M12W5<br>• Angled socket standard 2 m 570734 NEBU-M12W5-K-2-M12W5<br>• Angled plug<br>Connecting cable M12-M12, 5-pin Cable characteristic: suita- 5 m 574321 NEBU-M12G5-E-5-Q8N-M12G5<br>• Straight socket ble for use with energy 7.5 m 574322 NEBU-M12G5-E-7.5-Q8N-M12G5<br>• Straight plug chains 10 m 574323 NEBU-M12G5-E-10-Q8N-M12G5<br>Inscription label holder for connection block 536593 CPX-ST-1<br>User documentation<br>User documentation CPX CTEL master German 8034115 P.BE-CPX-CTEL-LK-DE<br>English 8034116 P.BE-CPX-CTEL-LK-EN<br>Spanish 8034117 P.BE-CPX-CTEL-LK-ES<br>French 8034118 P.BE-CPX-CTEL-LK-FR<br>Italian 8034119 P.BE-CPX-CTEL-LK-IT<br>Swedish 8034120 P.BE-CPX-CTEL-LK-ZH<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
132
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Axis controller for 4 electric axes
The control block CPX-CM-HPP is a • Max. 4 individual electric axes can module in the CPX terminal for conbe controlled via CAN bus trolling electric drives. • No programming required
- No programming required
- The control component is independent • Standardised communication with of the bus node used. the drives via the Festo Handling This means that Festo's electric drive and Positioning Profile (FHPP) technology is compatible with all in• Quick configuration and diagnostics dustrial communication interfaces. via CPX-FMT
The control block does not need to be • Simple, flexible and cost-effective programmed.
## **General technical data**
|This means that Festo's electric drive<br>technology is compatible with all in-<br>dustrial communication interfaces.<br>The control block does not need to be<br>programmed.<br>and Positioning Profile (FHPP)<br>• Quick configuration and diagnostics<br>via CPX-FMT<br>• Simple, flexible and cost-effective|This means that Festo's electric drive<br>technology is compatible with all in-<br>dustrial communication interfaces.<br>The control block does not need to be<br>programmed.<br>and Positioning Profile (FHPP)<br>• Quick configuration and diagnostics<br>via CPX-FMT<br>• Simple, flexible and cost-effective|
|---|---|
|**General technical data**<br>Fieldbus interface<br>1x socket M9, 5-pin||
|Protocol|FHPP|
|Max. address capacityinputs<br>[byte]|32|
|Max. address volume for outputs<br>[byte]|32|
|LED display (product-specific)|Error:<br>Fault|
||PL:<br>Power supply|
|Device-specific diagnostics|Diagnostic memory|
||Channel and module-oriented diagnostics|
||Undervoltage/short circuit of modules|
|Parameterisation|Forcingof channels|
||Systemparameters|
|Configuration support|Operator unit CPX-MMI|
|Total number of axes|4|
|Nominal operatingvoltage<br>[V DC]|24|
|Operatingvoltage range<br>[V DC]|18 ... 30|
|Power failure buffering<br>[ms]|10|
|Intrinsic current consumption at nominal operatingvoltage<br>[mA]|Typically80|
|Degree ofprotection to EN 60529 (withpluginserted)|IP65/IP67|
|Dimensions W x L x H (includinginterlinkingblock)<br>[mm]|50 x 107 x 55|
|Product weight (without interlinkingblock)<br>[g]|140|
|||
|**Materials**||
|Housing|PA-reinforced|
||PC|
|Note on materials|RoHS-compliant|
|PWIS conformity|VDMA24364-B2-L|
2023/10 – Subject to change
133
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Axis controller for 4 electric axes
## **Connection and display components**
**==> picture [524 x 455] intentionally omitted <==**
**----- Start of picture text -----**<br>
[1] 3-digit display<br>3<br>[2] Control interface<br>1 [3] LED display (product-specific)<br>[4] Inscription labels<br>4<br>2<br>4<br>4<br>Pin allocation – Control interface<br>Pin Signal Meaning<br>Socket M9, 5-pin<br>1 n.c. Not connected<br>2 n.c. Not connected<br>3 CAN_GND CAN ground<br>4 CAN_H CAN high<br>5 CAN_L CAN low<br>Housing Shielding Cable shield must be connected to functional earth (FE)<br>Permitted bus nodes/CEC<br>Bus node/CEC Protocol Max. number of CPX-CM-HPP modules<br>CPX-CEC... – 0<br>CPX-FB11 DeviceNet 2<br>CPX-FB13 PROFIBUS 2<br>CPX-FB14 CANopen 1<br>CPX-FB23-24 CC-Link 1 (as function module F23)<br>0 (as function module F24)<br>CPX-FB36 EtherNet/IP 2<br>CPX-FB37 EtherCAT 2<br>CPX-FB39 Sercos III 2<br>CPX-FB40 POWERLINK 2<br>CPX-FB43 PROFINET RT, M12 2<br>CPX-M-FB44 PROFINET RT, RJ45 2<br>CPX-M-FB45 PROFINET RT, SCRJ 2<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
134
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Axis controller for 4 electric axes
**==> picture [523 x 321] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data – Bus connection<br>Designation Part no. Type<br>Control block<br>For actuating up to 4 electric drives via CAN bus 562214 CPX-CM-HPP<br>Connecting cable<br>Connecting cable 2 m 563711 NEBC-M9W5-K-2-N-LE3<br>5 m 563712 NEBC-M9W5-K-5-N-LE3<br>Plug for CAN bus interface; 533783 FBS-SUB-9-WS-CO-K<br>Sub-D, 9-pin, without terminating resistor<br>Inscription labels<br>Inscription label holder for connection block 536593 CPX-ST-1<br>User documentation<br>Manual – Control block CPX-CM-HPP German 568683 CPX-CM-HPP-DE<br>English 568684 CPX-CM-HPP-EN<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
135
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Axis controller for 1 electric axis
The axis controller CPX-CMAX is intended exclusively for use in valve terminals CPX.
|**General technical data**|**General technical data**|
|---|---|
|**Operating voltage**||
|Operatingvoltage range<br>[V DC]|18 ... 30|
|Nominal operatingvoltage<br>[V DC]|24|
|Current consumption at nominal operatingvoltage<br>[mA]|200|
|Fuseprotection (short circuit)|Electronic|
|Power failure buffering<br>[ms]|10|
|||
|**Load voltage**||
|Load voltage range<br>[V DC]|20 ... 30|
|Nominal load voltage<br>[V DC]|24|
|Permissible load current<br>[A]|2.5|
|Fuseprotection (short circuit)|Electronic|
|||
|Number of axis strings|1|
|Axesper string|1|
|Length of connecting cable to axis<br>[m]|š30|
|Max. number of modules|7|
|Display|7-segment display|
|Assigned addresses<br>Outputs<br>[bit]<br>Inputs<br>[bit]|8x8|
||8x8|
|Operating modes|Record mode|
||Direct mode|
|Controller types|Position control|
||Force control|
|Diagnostics|Module-orientated|
||Via local 7-segment display|
|Status indication|Module status|
||Power load|
||Display/Error Axis X|
||MC Axis X|
|||
|**Control interface**||
|Data|CAN bus with Festoprotocol|
||Digital|
|Electrical connection|5-pin|
||M9|
||Socket|
|||
|Materials: Housing|PA-reinforced|
|Note on materials|RoHS-compliant|
|PWIS conformity|VDMA24364-B2-L|
|Product weight<br>[g]|240|
|Dimensions<br>Length<br>[mm]<br>Width<br>[mm]<br>Height<br>[mm]|107|
||50|
||55|
Subject to change – 2023/10
136
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Axis controller for 1 electric axis
**==> picture [523 x 514] intentionally omitted <==**
**----- Start of picture text -----**<br>
Operating and environmental conditions<br>Ambient temperature [°C] –5 ... +50<br>Relative humidity [%] 5 ... 95, non-condensing<br>Degree of protection to IEC 60529 IP65<br>Connection and display components<br>[1] 3-digit display<br>3<br>[2] Control interface<br>1 [3] Status LEDs<br>[4] Inscription labels<br>4<br>2<br>4<br>4<br>Pin allocation – Control interface<br>Pin Signal Designation<br>1 +24 V Nominal operating voltage<br>2 +24 V Load voltage<br>3 0 V Ground<br>4 CAN_H CAN high<br>5 CAN_L CAN low<br>Housing Shielding Cable shielding<br>Permitted bus nodes/CEC<br>Bus node/CEC Protocol Max. number of CMAX modules<br>CPX-CEC... – 8<br>CPX-FB11 DeviceNet [1)] 8<br>CPX-FB13 PROFIBUS [2)] 8<br>CPX-FB14 CANopen 4<br>CPX-FB23-24 CC-Link 4 (as function module F23)<br>8 (as function module F24)<br>CPX-FB36 EtherNet/IP 8<br>CPX-FB37 EtherCAT 8<br>CPX-FB39 Sercos III 8<br>CPX-FB40 POWERLINK 8<br>CPX-FB43 PROFINET RT, M12 8<br>CPX-M-FB44 PROFINET RT, RJ45 8<br>CPX-M-FB45 PROFINET RT, SCRJ 8<br>**----- End of picture text -----**<br>
1) As of revision 20 (R20)
2) As of revision 23 (R23)
2023/10 – Subject to change
137
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Axis controller for 1 electric axis
**==> picture [524 x 417] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Brief description Part no. Type<br>Axis controller<br>Order code in the CPX configurator: T21 548932 CPX-CMAX-C1-1<br>Connecting cables<br>Connecting cable with angled plug and angled socket 0.25 m 540327 KVI-CP-3-WS-WD-0.25<br>0.5 m 540328 KVI-CP-3-WS-WD-0.5<br>2 m 540329 KVI-CP-3-WS-WD-2<br>5 m 540330 KVI-CP-3-WS-WD-5<br>8 m 540331 KVI-CP-3-WS-WD-8<br>Connecting cable with straight plug and straight socket 2 m 540332 KVI-CP-3-GS-GD-2<br>5 m 540333 KVI-CP-3-GS-GD-5<br>8 m 540334 KVI-CP-3-GS-GD-8<br>Connecting component for cabinet through feed 543252 KVI-CP-3-SSD<br>Screws<br>For mounting on the metal interlinking block 550219 CPX-M-M3X22-4X<br>Inscription labels<br>Inscription labels 6x10, in frames 64 pieces 18576 IBS-6x10<br>User documentation<br>Manual – Axis controller CPX-CMAX [1)] German 559750 P.BE-CPX-CMAX-SYS-DE<br>English 559751 P.BE-CPX-CMAX-SYS-EN<br>Spanish 559752 P.BE-CPX-CMAX-SYS-ES<br>French 559753 P.BE-CPX-CMAX-SYS-FR<br>Italian 559754 P.BE-CPX-CMAX-SYS-IT<br>**----- End of picture text -----**<br>
1) User documentation in paper form is not included in the scope of delivery.
Subject to change – 2023/10
138
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – End-position controller
The end-position controller CPX-CMPX is intended exclusively for use in valve terminals CPX.
|**General technical data**|**General technical data**|
|---|---|
|**Operating voltage**||
|Operatingvoltage range<br>[V DC]|18 ... 30|
|Nominal operatingvoltage<br>[V DC]|24|
|Current consumption at nominal operatingvoltage<br>[mA]|80|
|||
|**Load voltage**||
|Load voltage range<br>[V DC]|20 ... 30|
|Nominal load voltage<br>[V DC]|24|
|Permissible load current<br>[A]|2.5|
|||
|Number of axesper module|1|
|Length of connecting cable to axis<br>[m]|š30|
|Max. number of modules|9|
|Display|7-segment display|
|Control elements|3 buttons|
|Assigned addresses<br>Outputs<br>[bit]<br>Inputs<br>[bit]|6x8|
||6x8|
|Diagnostics|Module-orientated|
||Via local 7-segment display|
|Status indication|Module status|
||Power load|
|||
|**Control interface**||
|Data|CAN bus with Festoprotocol|
||Digital|
|Electrical connection|5-pin|
||M9|
||Socket|
|||
|Materials: Housing|PA-reinforced|
|PWIS conformity|VDMA24364-B2-L|
|Product weight<br>[g]|140|
|Dimensions<br>Length<br>[mm]<br>Width<br>[mm]<br>Height<br>[mm]|107|
||50|
||55|
2023/10 – Subject to change
139
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – End-position controller
**==> picture [524 x 60] intentionally omitted <==**
**----- Start of picture text -----**<br>
Operating and environmental conditions<br>Ambient temperature [°C] –5 ... +50<br>Relative humidity [%] 5 ... 95, non-condensing<br>Degree of protection to IEC 60529 IP65<br>CE marking (see declaration of conformity) To EU EMC Directive<br>**----- End of picture text -----**<br>
## **Connection and display components**
[1] 3-digit display 3 [2] Control interface 1 [3] Status LEDs [4] Operating buttons [5] Inscription labels 4 5 2 5 ~~5~~
## **Pin allocation – Control interface**
**==> picture [524 x 254] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pin Signal Designation<br>1 +24 V Nominal operating voltage<br>2 +24 V Load voltage<br>3 0 V Ground<br>4 CAN_H CAN high<br>5 CAN_L CAN low<br>Housing Shielding Cable shielding<br>Permitted bus nodes/CEC<br>Bus node/CEC Protocol Max. no. of CMPX modules<br>CPX-CEC... – 9<br>CPX-FB11 DeviceNet [1)] 9<br>CPX-FB13 PROFIBUS [2)] 9<br>CPX-FB14 CANopen 5<br>CPX-FB23-24 CC-Link 5 (as function module F23)<br>9 (as function module F24)<br>CPX-FB36 EtherNet/IP 9<br>CPX-FB37 EtherCAT 9<br>CPX-FB39 Sercos III 9<br>CPX-FB40 POWERLINK 9<br>CPX-FB43 PROFINET RT, M12 9<br>CPX-M-FB44 PROFINET RT, RJ45 9<br>CPX-M-FB45 PROFINET RT, SCRJ 9<br>**----- End of picture text -----**<br>
1) As of revision 20 (R20)
2) As of revision 23 (R23)
Subject to change – 2023/10
140
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – End-position controller
**==> picture [523 x 417] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Brief description Part no. Type<br>End-position controller<br>Order code in the CPX configurator: T20 548931 CPX-CMPX-C-1-H1<br>Connecting cables<br>Connecting cable with angled plug and angled socket 0.25 m 540327 KVI-CP-3-WS-WD-0.25<br>0.5 m 540328 KVI-CP-3-WS-WD-0.5<br>2 m 540329 KVI-CP-3-WS-WD-2<br>5 m 540330 KVI-CP-3-WS-WD-5<br>8 m 540331 KVI-CP-3-WS-WD-8<br>Connecting cable with straight plug and straight socket 2 m 540332 KVI-CP-3-GS-GD-2<br>5 m 540333 KVI-CP-3-GS-GD-5<br>8 m 540334 KVI-CP-3-GS-GD-8<br>Connecting component for cabinet through feed 543252 KVI-CP-3-SSD<br>Screws<br>For mounting on the metal interlinking block 550219 CPX-M-M3X22-4X<br>Inscription labels<br>Inscription labels 6x10, in frames 64 pieces 18576 IBS-6x10<br>User documentation<br>Manual – End-position controller CPX-CMPX [1)] German 555479 P.BE-CPX-CMPX-SYS-DE<br>English 555480 P.BE-CPX-CMPX-SYS-EN<br>Spanish 555481 P.BE-CPX-CMPX-SYS-ES<br>French 555482 P.BE-CPX-CMPX-SYS-FR<br>Italian 555483 P.BE-CPX-CMPX-SYS-IT<br>**----- End of picture text -----**<br>
1) User documentation in paper form is not included in the scope of delivery.
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
141
Terminal CPX
## Data sheet – Measuring module for displacement encoder
The measuring module CPX-CMIX is intended exclusively for use in valve terminals CPX.
|**General technical data**|**General technical data**|
|---|---|
|**Operating voltage**||
|Operatingvoltage range<br>[V DC]|18 ... 30|
|Nominal operatingvoltage<br>[V DC]|24|
|Current consumption at nominal operatingvoltage<br>[mA]|80|
|Short circuit current rating|Yes|
|Power failure buffering<br>[ms]|10|
|||
|Number of axis strings|1|
|Axesper string|1|
|Length of connecting cable to axis<br>[m]|š30|
|Max. number of modules|9|
|Display|7-segment display|
|Assigned addresses<br>Outputs<br>[bit]<br>Inputs<br>[bit]|6x8|
||6x8|
|Diagnostics|Channel and module-oriented|
||Via local 7-segment display|
||Undervoltage of modules|
||Undervoltage of measuringsystem|
|Status indication|Power load|
||Error|
|||
|**Control interface**||
|Data|CAN bus with Festoprotocol|
||Digital|
|Electrical connection|5-pin|
||M9|
||Socket|
|||
|Materials: Housing|PA-reinforced|
|Note on materials|RoHS-compliant|
|PWIS conformity|VDMA24364-B2-L|
|Product weight<br>[g]|140|
|Dimensions<br>Length<br>[mm]<br>Width<br>[mm]<br>Height<br>[mm]|107|
||50|
||55|
Subject to change – 2023/10
142
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Measuring module for displacement encoder
**==> picture [523 x 60] intentionally omitted <==**
**----- Start of picture text -----**<br>
Operating and environmental conditions<br>Ambient temperature [°C] –5 ... +50<br>Storage temperature [°C] –20 ... +70<br>Relative humidity [%] 5 ... 95, non-condensing<br>Degree of protection to IEC 60529 IP65<br>**----- End of picture text -----**<br>
## **Connection and display components**
**==> picture [523 x 439] intentionally omitted <==**
**----- Start of picture text -----**<br>
[1] 3-digit display<br>3<br>[2] Control interface<br>1 [3] Status LEDs<br>[4] Inscription labels<br>4<br>2<br>4<br>4<br>Pin allocation – Control interface<br>Pin Signal Designation<br>1 +24 V Nominal operating voltage<br>2 +24 V Load voltage<br>3 0 V Ground<br>4 CAN_H CAN high<br>5 CAN_L CAN low<br>Housing Shielding Cable shielding<br>Permitted bus nodes/CEC<br>Bus node/CEC Protocol Max. number of CMIX modules<br>CPX-CEC... – 9<br>CPX-FB11 DeviceNet [1)] 9<br>CPX-FB13 PROFIBUS [2)] 9<br>CPX-FB14 CANopen 5<br>CPX-FB23-24 CC-Link 5 (as function module F23)<br>9 (as function module F24)<br>CPX-FB36 EtherNet/IP 9<br>CPX-FB37 EtherCAT 9<br>CPX-FB39 Sercos III 9<br>CPX-FB40 POWERLINK 9<br>CPX-FB43 PROFINET RT, M12 9<br>CPX-M-FB44 PROFINET RT, RJ45 9<br>CPX-M-FB45 PROFINET RT, SCRJ 9<br>**----- End of picture text -----**<br>
1) As of revision 20 (R20)
2) As of revision 23 (R23)
2023/10 – Subject to change
143
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Measuring module for displacement encoder
**==> picture [524 x 461] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Brief description Part no. Type<br>Measuring module<br>Order code in the CPX configurator: T23 567417 CPX-CMIX-M1-1<br>Connecting cables<br>Connecting cable with angled plug and angled socket 0.25 m 540327 KVI-CP-3-WS-WD-0.25<br>0.5 m 540328 KVI-CP-3-WS-WD-0.5<br>2 m 540329 KVI-CP-3-WS-WD-2<br>5 m 540330 KVI-CP-3-WS-WD-5<br>8 m 540331 KVI-CP-3-WS-WD-8<br>Connecting cable with straight plug and straight socket 2 m 540332 KVI-CP-3-GS-GD-2<br>5 m 540333 KVI-CP-3-GS-GD-5<br>8 m 540334 KVI-CP-3-GS-GD-8<br>Connecting component for cabinet through feed 543252 KVI-CP-3-SSD<br>For displacement encoder MME: 2 m 575898 NEBP-M16W6-K-2-M9W5<br>Connection between displacement encoder MME and measuring module<br>CPX-CMIX<br>Screws<br>For mounting on the metal interlinking block 550219 CPX-M-M3X22-4X<br>Inscription labels<br>Inscription labels 6x10, in frames 64 pieces 18576 IBS-6x10<br>User documentation<br>Manual – Measuring module CPX-CMIX [1)] German 567053 P.BE-CPX-CMIX-DE<br>English 567054 P.BE-CPX-CMIX-EN<br>Spanish 567055 P.BE-CPX-CMIX-ES<br>French 567056 P.BE-CPX-CMIX-FR<br>Italian 567057 P.BE-CPX-CMIX-IT<br>**----- End of picture text -----**<br>
1) User documentation in paper form is not included in the scope of delivery.
Subject to change – 2023/10
d **Internet: www.festo.com/catalogue/...**
144
Terminal CPX
## Data sheet – Input module, digital
## **Area of application**
## **Function**
Digital input modules enable the connection of two-wire and three-wire sensors (proximity switches, inductive or capacitive sensors, etc.).
- Input modules for 24 V DC sensor supply voltage
- PNP or NPN logic
capacitive sensors, etc.). • Supports connection blocks with Depending on the connection block seM12, M8, Sub-D and terminal conlected, the module supports various nection or, connection concepts with different • Module features can be parameternumbers of sockets (single or double ised allocation). • The input module receives the supply voltage for the electronics and the sensors from the interlinking block • Module protection and diagnostics through integrated electronic protection **General technical data** Type CPX-4DE CPX-8DE CPX-8DE-D CPX-8NDE eee Number of inputs 4 8 8 8 Max. residual current of inputs per module [A] 0.7 1 0.7 0.7 ~~——~~ Fuse protection Internal electronic Internal electronic Internal electronic Internal electronic fuse per module fuse per module fuse per channel fuse per module ~~ce~~ Intrinsic current consumption at operating voltage [mA] Typically 15 Operating voltage Nominal value [V DC] 24 Permissible range [V DC] 18 ... 30 ~~a ———~~ Galvanic isolation Channel – channel No Channel – internal bus No ~~a ———————~~ ~~**—** —~~ Switching level Signal 0 [V DC] š 5 › 11 Signal 1 [V DC] ~~—~~ › 11 š 5 ~~ee~~ Input debounce time [ms] 3 (0.1, 10, 20 parameterisable) ~~OO~~ Input characteristic IEC 1131-T2 Switching logic Positive logic (PNP) ~~—~~ Negative logic (NPN) ~~O~~ LED displays ~~O~~ Group diagnostics ~~—~~ 1 1 1 1 Channel diagnostics – – 8 – ~~a~~ Channel status ~~**—**~~ 4 8 8 8 ~~ce~~ Diagnostics Short circuit/overload per channel Parameterisation • Module monitoring • Behaviour after short circuit • Input debounce time • Signal extension time ~~ce~~ Degree of protection to EN 60529 Depending on connection block Temperature range Operation [°C] –5 ... +50 Storage/transport [°C] –20 ... +70 ~~aOO~~ Materials ~~——————— ——~~ Reinforced PA, PC PWIS conformity VDMA24364-B2-L ~~OOee~~ Grid dimension [mm] ~~—~~ 50 ~~— ee~~ Dimensions (including interlinking block and connection block) W x L x H [mm] 50 x 107 x 50 ~~eee~~ Product weight [g] 39 39 45 40 ~~mai~~ 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 145
145
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, digital
**==> picture [524 x 268] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection and display components<br>CPX-4DE CPX-8DE CPX-8DE-D CPX-8NDE<br>1 1 1 3 1<br>2 2 2 2<br>1 1 3 1<br>[1] Status LEDs (green) [2] Error LED (red, module error) [3] Channel-related error LEDs (red) For allocation to inputs<br>a Pin allocation for module<br>Combinations of connection blocks and digital input modules<br>Connection blocks Part no. Digital input modules<br>CPX-4DE CPX-8DE CPX-8DE-D CPX-8NDE<br>CPX-AB-8-M8-3POL 195706 h h h h<br>CPX-AB-4-M12X2-5POL 195704 h h h h<br>CPX-AB-4-M12X2-5POL-R 541254 h h h h<br>CPX-AB-8-KL-4POL 195708 h h h h<br>CPX-AB-1-SUB-BU-25POL 525676 h h h h<br>CPX-M-AB-4-M12X2-5POL 549367 h h h h<br>**----- End of picture text -----**<br>
**==> picture [524 x 332] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pin allocation<br>Connection block inputs CPX-4DE CPX-8DE, CPX-8DE-D and CPX-8NDE<br>CPX-AB-8-M8-3POL<br>X1.1: 24 VSEN X5.1: 24 VSEN X1.1: 24 VSEN x X5.1: 24 VSEN x+4<br>X1.3: 0 VSEN X5.3: 0 VSEN X1.3: 0 VSEN x X5.3: 0 VSEN x+4<br>X1.4: Input x X5.4: Input x+2 X1.4: Input x X5.4: Input x+4<br>X2.1: 24 VSEN X6.1: 24 VSEN X2.1: 24 VSEN x+1 X6.1: 24 VSEN x+5<br>X2.3: 0 VSEN X6.3: 0 VSEN X2.3: 0 VSEN x+1 X6.3: 0 VSEN x+5<br>X2.4: Input x+1 X6.4: Input x+3 X2.4: Input x+1 X6.4: Input x+5<br>X3.1: 24 VSEN X7.1: 24 VSEN X3.1: 24 VSEN x+2 X7.1: 24 VSEN x+6<br>X3.3: 0 VSEN X7.3: 0 VSEN X3.3: 0 VSEN x+2 X7.3: 0 VSEN x+6<br>X3.4: Input x+1 X7.4: Input x+3 X3.4: Input x+2 X7.4: Input x+6<br>X4.1: 24 VSEN X8.1: 24 VSEN X4.1: 24 VSEN x+3 X8.1: 24 VSEN x+7<br>X4.3: 0 VSEN X8.3: 0 VSEN X4.3: 0 VSEN x+3 X8.3: 0 VSEN x+7<br>X4.4: n.c. X8.4: n.c. X4.4: Input x+3 X8.4: Input x+7<br>CPX-AB-4-M12X2-5POL, CPX-AB-4-M12X2-5POL-R [1)] and CPX-M-AB-4-M12X2-5POL<br>X1.1: 24 VSEN X3.1: 24 VSEN X1.1: 24 VSEN x X3.1: 24 VSEN x+4<br>X1.2: Input x+1 X3.2: Input x+3 X1.2: Input x+1 X3.2: Input x+5<br>X1.3: 0 VSEN X3.3: 0 VSEN X1.3: 0 VSEN x X3.3: 0 VSEN x+4<br>X1.4: Input x X3.4: Input x+2 X1.4: Input x X3.4: Input x+4<br>X1.5: FE X3.5: FE X1.5: FE X3.5: FE<br>X2.1: 24 VSEN X4.1: 24 VSEN X2.1: 24 VSEN x+2 X4.1: 24 VSEN x+6<br>X2.2: n.c. X4.2: n.c. X2.2: Input x+3 X4.2: Input x+7<br>X2.3: 0 VSEN X4.3: 0 VSEN X2.3: 0 VSENx+2 X4.3: 0 VSEN x+6<br>X2.4: Input x+1 X4.4: Input x+3 X2.4: Input x+2 X4.4: Input x+6<br>X2.5: FE X4.5: FE X2.5: FE X4.5: FE<br>**----- End of picture text -----**<br>
1) Speedcon quick lock, additional shielding on metal thread
Subject to change – 2023/10
146
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, digital
## **Pin allocation**
**==> picture [523 x 397] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection block inputs CPX-4DE CPX-8DE, CPX-8DE-D and CPX-8NDE<br>CPX-AB-8-KL-4POL<br>X1.0: 24 VSEN X5.0: 24 VSEN X1.0: 24 VSEN x X5.0: 24 VSEN x+4<br>X1 .0 .0 X5<br>.1 .1 X1.1: 0 VSEN X5.1: 0 VSEN X1.1: 0 VSEN x X5.1: 0 VSEN x+4<br>.2.3 .2.3 X1.2: Input x X5.2: Input x+2 X1.2: Input x X5.2: Input x+4<br>.0 .0 X1.3: FE X5.3: FE X1.3: FE X5.3: FE<br>X2 .1.2 .1.2 X6 X2.0: 24 VSEN X6.0: 24 VSEN X2.0: 24 VSEN x+1 X6.0: 24 VSEN x+5<br>.3.0 .3.0 X2.1: 0 VSEN X6.1: 0 VSEN X2.1: 0 VSEN x+1 X6.1: 0 VSEN x+5<br>X3 .1.2 .1.2 X7 X2.2: Input x+1 X6.2: Input x+3 X2.2: Input x+1 X6.2: Input x+5<br>.3 .3 X2.3: FE X6.3: FE X2.3: FE X6.3: FE<br>.0.1 .0.1 X3.0: 24 VSEN X7.0: 24 VSEN X3.0: 24 VSEN x+2 X7.0: 24 VSEN x+6<br>X4 .2.3 .2.3 X8 X3.1: 0 VSEN X7.1: 0 VSEN X3.1: 0 VSEN x+2 X7.1: 0 VSEN x+6<br>X3.2: Input x+1 X7.2: Input x+3 X3.2: Input x+2 X7.2: Input x+6<br>X3.3: FE X7.3: FE X3.3: FE X7.3: FE<br>X4.0: 24 VSEN X8.0: 24 VSEN X4.0: 24 VSEN x+3 X8.0: 24 VSEN x+7<br>X4.1: 0 VSEN X8.1: 0 VSEN X4.1: 0 VSEN x+3 X8.1: 0 VSEN x+7<br>X4.2: n.c. X8.2: n.c. X4.2: Input x+3 X8.2: Input x+7<br>X4.3: FE X8.3: FE X4.3: FE X8.3: FE<br>CPX-AB-1-SUB-BU-25POL<br>1: Input x 14: Input x+2 1: Input x 14: Input x+4<br>2: Input x+1 15: Input x+3 2: Input x+1 15: Input x+5<br>3: Input x+1 16: Input x+3 3: Input x+2 16: Input x+6<br>4: n.c. 17: n.c. 4: Input x+3 17: Input x+7<br>5: 24 VSEN 18: 24 VSEN 5: 24 VSEN x+1 18: 24 VSEN x+4<br>6: 0 VSEN 19: 24 VSEN 6: 0 VSEN x+1 19: 24 VSEN x+5<br>7: 24 VSEN 20: 24 VSEN 7: 24 VSEN x+3 20: 24 VSEN x+6<br>8: 0 VSEN 21: 24 VSEN 8: 0 VSEN x+3 21: 24 VSEN x+7<br>9: 24 VSEN 22: 0 VSEN 9: 24 VSEN x 22: 0 VSEN x+2 u. 3<br>10: 24 VSEN 23: 0 VSEN 10: 24 VSEN x+2 23: 0 VSEN x+2 u. 3<br>11: 0 VSEN 24: 0 VSEN 11: 0 VSEN x 24: 0 VSEN x+2 u. 3<br>12: 0 VSEN 25: FE 12: 0 VSEN x+2 25: FE<br>13: FE Housing: FE 13: FE Housing: FE<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
147
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, digital
## **Ordering data**
**==> picture [524 x 490] intentionally omitted <==**
**----- Start of picture text -----**<br>
Designation Part no. Type<br>Input module, digital<br>4 digital inputs, positive logic (PNP) 195752 CPX-4DE<br>8 digital inputs, positive logic (PNP) 195750 CPX-8DE<br>8 digital inputs, positive logic (PNP), enhanced diagnostic function 541480 CPX-8DE-D<br>8 digital inputs, negative logic (NPN) 543813 CPX-8NDE<br>Connection block<br>Plastic 8x socket M8, 3-pin 195706 CPX-AB-8-M8-3POL<br>4x socket M12, 5-pin 195704 CPX-AB-4-M12X2-5POL<br>4x socket, M12 with quick-lock technology, 5-pin 541254 CPX-AB-4-M12X2-5POL-R<br>Spring-loaded terminal, 32-pin 195708 CPX-AB-8-KL-4POL<br>1x socket, Sub-D, 25-pin 525676 CPX-AB-1-SUB-BU-25POL<br>Metal 4x socket M12, 5-pin 549367 CPX-M-AB-4-M12X2-5POL<br>Distributor<br>Modular system for all types of sensor/actuator distributor – NEDY- ...<br>a Internet: nedy<br>1x plug M12, 4-pin 2x socket M8, 3-pin 8005311 NEDY-L2R1-V1-M8G3-N-M12G4<br>2x socket M12, 5-pin 8005310 NEDY-L2R1-V1-M12G5-N-M12G4<br>Plug<br>Plug M8, 3-pin Solderable 18696 SEA-GS-M8<br>Screw-in 192009 SEA-3GS-M8-S<br>M12, 4-pin, PG7 18666 SEA-GS-7<br>M12, PG7, 4-pin for cable @ 2.5 mm 192008 SEA-4GS-7-2.5<br>M12, 4-pin, PG9 18778 SEA-GS-9<br>M12, 4 pin for 2 cables 18779 SEA-GS-11-DUO<br>M12 for 2 cables, 5-pin 192010 SEA-5GS-11-DUO<br>M12, 5-pin 175487 SEA-M12-5GS-PG7<br>Sub-D plug, 25-pin 527522 SD-SUB-D-ST25<br>Connecting cable<br>Connecting cable M8-M8 0.5 m 541346 NEBU-M8G3-K-0.5-M8G3<br>1.0 m 541347 NEBU-M8G3-K-1-M8G3<br>2.5 m 541348 NEBU-M8G3-K-2.5-M8G3<br>5.0 m 541349 NEBU-M8G3-K-5-M8G3<br>Modular system for a choice of connecting cables – NEBU- ...<br>a Internet: nebu<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
148
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, digital
**==> picture [523 x 226] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>Cover<br>Cover for CPX-AB-8-KL-4POL (IP65, IP67) 538219 AK-8KL<br>• 8 cable through feeds M9<br>• 1 cable through feed for multi-pin plug<br>Fittings kit 538220 VG-K-M9<br>Screening plate<br>Screening plate for M12 connections 526184 CPX-AB-S-4-M12<br>User documentation<br>User documentation German 526439 P.BE-CPX-EA-DE<br>English 526440 P.BE-CPX-EA-EN<br>Spanish 526441 P.BE-CPX-EA-ES<br>French 526442 P.BE-CPX-EA-FR<br>Italian 526443 P.BE-CPX-EA-IT<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
149
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Input module, digital, NAMUR
## **Function**
## **Area of application**
Digital input modules enable the con• Input modules for 24 V DC sensor nection of up to 8 NAMUR sensors (or supply voltage wired mechanical contacts). In addi• Module features can be parametertion, the first 4 channels can alternaised tively be used as counters or for fre• The input module receives the supquency measurement. ply voltage for the electronics and M12 and terminal strip connection the sensors from the interlinking technology can be used. block SS • Module protection and diagnostics through integrated electronic protection in each channel **General technical data** Type CPX-P-8DE-N a Number of inputs 8 Maximum cable length [m] 200 Input debounce time [ms] 3 (0, 10, 20 parameterisable) Fuse protection (short circuit) Internal electronic fuse per channel ~~ee~~ Module current consumption (power supply for electronics) [mA] Typically 75 Nominal operating voltage [V DC] 24 (reverse polarity protected) ~~ee~~ Permissible voltage fluctuations [%] ±25 Power failure buffering [ms] 20 Residual ripple [Vss] 0.4 ~~—~~ Galvanic isolation Channel – channel No Channel – internal bus Yes ~~rs~~ Input characteristics To EN 60947-5-6 ~~eee a~~ Switching level To EN 60947-5-6 LED displays Group diagnostics 1 Channel diagnostics 8 ~~————~~ Channel status 8 Diagnostics Wire break per channel Limit value violation per channel Parameterisation error Overload per channel Parameterisation Data format Input debounce time per channel Input function per channel Replacement value in diagnostic case per channel ~~[—~~ Upper limit value per channel Signal extension time per channel ~~[do~~ Gate time per channel Monitoring of limit values per channel Monitoring of short circuit per channel ~~[+++~~ Monitoring of wire break per channel ~~Y+_— sdoo~~ MonitorinLower limit value g of parametersper channel Upper limit value per channel Counter configuration per channel Control elements DIL switch ~~ooeS[do~~ Additional functions Frequency measurement Counter function ~~a cee~~ Degree of protection to EN 60529 Depending on the connection block ~~=~~ 150 d **Internet: www.festo.com/catalogue/...** Subject to change – 2023/10
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, digital, NAMUR
**==> picture [523 x 174] intentionally omitted <==**
**----- Start of picture text -----**<br>
General technical data<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block and connection block) W x L x H [mm] 50 x 107 x 70<br>Product weight [g] 100<br>Materials<br>Housing PA-reinforced<br>PC<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364 zone III<br>Operating and environmental conditions<br>Ambient temperature [°C] –5 ... +50<br>Storage temperature [°C] –20 ... +70<br>Relative humidity [%] 95, non-condensing<br>**----- End of picture text -----**<br>
## **Connection and display components**
|~~1~~<br>~~3~~|2<br>[1] Status LEDs (green): for allocation<br>to the inputsapin allocation of<br>the module<br>[2] Error LED (red, module error)<br>[3] Channel-related error LEDs (red)|2<br>[1] Status LEDs (green): for allocation<br>to the inputsapin allocation of<br>the module<br>[2] Error LED (red, module error)<br>[3] Channel-related error LEDs (red)|2<br>[1] Status LEDs (green): for allocation<br>to the inputsapin allocation of<br>the module<br>[2] Error LED (red, module error)<br>[3] Channel-related error LEDs (red)|
|---|---|---|---|
||||2|
|||||
|||||
|~~1~~<br>~~3~~||||
## **Combinations of bus nodes/control blocks with digital input module**
**==> picture [523 x 222] intentionally omitted <==**
**----- Start of picture text -----**<br>
Bus node/control block Part no. Digital input module<br>CPX-P-8DE-N<br>CPX-CEC-C1-V3 3473128 h<br>CPX-CEC-M1-V3 3472765 h<br>CPX-CEC-S1-V3 3472425 h<br>CPX-FB11 526172 h<br>CPX-FB13 195740 h<br>CPX-FB14 526174 h<br>CPX-FB36 1912451 h<br>CPX-FB37 2735960 h<br>CPX-FB43 8110369 h<br>CPX-M-FB44 8110370 h<br>CPX-M-FB45 8110371 h<br>Combinations of connection block and digital input module<br>Connection blocks Part no. Digital input module<br>CPX-P-8DE-N<br>CPX-P-AB-4XM12-4POL 565706 h<br>CPX-P-AB-2XKL-8POL 565704 h<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
151
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, digital, NAMUR
## **Pin allocation**
**==> picture [524 x 272] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection block inputs CPX-P-8DE-N<br>CPX-P-AB-4XM12-4POL<br>X1.1: BN+ [0] X3.1: BN+ [4]<br>X1.2: BU– [0] X3.2: BU– [4]<br>X1.3: BN+ [1] X3.3: BN+ [5]<br>X1.4: BU– [1] X3.4: BU– [5]<br>X2.1: BN+ [2] X4.1: BN+ [6]<br>X2.2: BU– [2] X4.2: BU– [6]<br>X2.3: BN+ [3] X4.3: BN+ [7]<br>X2.4: BU– [3] X4.4: BU– [7]<br>CPX-P-AB-2XKL-8POL<br>X1.1: BN+ [0] X2.1: BN+ [4]<br>X1.2: BU– [0] X2.2: BU– [4]<br>X1.3: BN+ [1] X2.3: BN+ [5]<br>X1.4: BU– [1] X2.4: BU– [5]<br>X1.5: BN+ [2] X2.5: BN+ [6]<br>X1.6: BU– [2] X2.6: BU– [6]<br>X1.7: BN+ [3] X2.7: BN+ [7]<br>X1.8: BU– [3] X2.8: BU– [7]<br>**----- End of picture text -----**<br>
**==> picture [524 x 296] intentionally omitted <==**
**----- Start of picture text -----**<br>
Combinations of interlinking block/digital input module<br>Interlinking blocks Part no. Digital input module<br>CPX-P-8DE-N<br>CPX-GE-EV-S 195746 –<br>CPX-GE-EV-S-VL 8022170 –<br>CPX-GE-EV-S-7/8-4POL 541248 –<br>CPX-M-GE-EV-S-7/8-CIP-4P 568956 –<br>CPX-GE-EV-S-7/8-5POL 541244 –<br>CPX-GE-EV-S-7/8-5POL-VL 8022172 –<br>CPX-M-GE-EV-S-7/8-5POL 550208 h<br>CPX-M-GE-EV-S-7/8-5POL-VL 8022165 h<br>CPX-M-GE-EV-S-M12-5POL 8098392 –<br>CPX-M-GE-EV-S-PP-5POL 563057 –<br>CPX-GE-EV 195742 –<br>CPX-M-GE-EV 550206 h<br>CPX-GE-EV-Z 195744 –<br>CPX-GE-EV-Z-VL 8022166 –<br>CPX-GE-EV-Z-7/8-4POL 541250 –<br>CPX-GE-EV-Z-7/8-5POL 541246 –<br>CPX-GE-EV-Z-7/8-5POL-VL 8022173 –<br>CPX-M-GE-EV-Z-7/8-5POL 550210 h<br>CPX-M-GE-EV-Z-7/8-5POL-VL 8022158 h<br>CPX-M-GE-EV-Z-PP-5POL 563058 –<br>CPX-GE-EV-V 533577 –<br>CPX-GE-EV-V-VL 8022171 –<br>CPX-GE-EV-V-7/8-4POL 541252 –<br>CPX-M-GE-EV-W-M12-5POL 8098391 –<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
152
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, digital, NAMUR
**==> picture [524 x 551] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>Input module, digital, NAMUR<br>8 digital inputs 565933 CPX-P-8DE-N<br>Connection block<br>Plastic 4x socket, M12, 4-pin 565706 CPX-P-AB-4XM12-4POL<br>2x plug, 8-pin 565704 CPX-P-AB-2XKL-8POL<br>Plug<br>Socket 8-pin Spring-loaded terminal 565712 NECU-L3G8-C1<br>Screw terminal 565710 NECU-L3G8-C2<br>Plug M12x1, 4-pin, straight, A-coded Screw terminal Connection cross section 192008 SEA-4GS-7-2.5<br>0.14 ... 0.5 mm [2]<br>Nominal conductor cross section 18666 SEA-GS-7<br>0.14 ... 0.75 mm [2]<br>Permissible cable @ 4 ... 6 mm<br>Connection cross section 18778 SEA-GS-9<br>0.75 mm [2]<br>Permissible cable @ 6 ... 8 mm<br>Distributor<br>Modular system for all types of sensor/actuator distributor – NEDY- ...<br>a Internet: nedy<br>Cover<br>Cover cap for closing off unused connections (10 pieces) For M12 connec- 165592 ISK-M12<br>tions<br>Coding element<br>To ensure that a coded socket NECU-L3G8 can only be inserted in the matching For NECU-L3G8 565713 CPX-P-KDS-AB-2XKL<br>coded connection block CPX-P-AB-2XKL (96 of each)<br>User documentation<br>User documentation German 575378 P.BE-CPX-P-EA-DE<br>English 575379 P.BE-CPX-P-EA-EN<br>Spanish 575380 P.BE-CPX-P-EA-ES<br>French 575381 P.BE-CPX-P-EA-FR<br>Italian 575382 P.BE-CPX-P-EA-IT<br>Swedish 575383 P.BE-CPX-P-EA-SV<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
153
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Input module, digital, PROFIsafe
## **Function**
## **Area of application**
The PROFIsafe input module has 8 in• Input module for 24 V DC sensor put channels whose signal status is supply voltage detected for safety reasons, with the • Supports connection blocks with information transmitted to a suitable M12 and terminal connection safety controller using the PROFIsafe • Module features can be parametersafety protocol in combination with the ised appropriate fieldbus (PROFINET or • The input module receives the supPROFIBUS). This function is exclusively ply voltage for the electronics and available for safety controllers using the sensors from the interlinking the PROFIsafe protocol, profile version block 2.4. • Module protection and diagnostics through integrated electronic protection
## **Description**
- Module-based passivation Channel-based passivation
- While channel-based passivation is In the case of channel-based passiva• The input information for unaffected disabled, the input module, in accordtion, when a channel error occurs, the channel pairs does not change ance with PROFIsafe specification, input module switches the input infor• The input module remains integratswitches all information in the input mation of the affected channel pair to ed. image to the safe status, even when 0, depending on the function mode. • The input module indicates the curthere is only one channel error. rent channel error status to the control unit via the input image.
- Applications
- The inputs on the PROFIsafe input The function mode has an influence on There are 5 independent clock outputs The entire input module is designed to module can be combined for multhe evaluation of the input signals, available for safe operation of passive ensure that the input channels provide ti-channel sensor applications. Every and optionally on the generation of sensors; the pulse patterns are used in either secure data or no data at all, two inputs form a channel pair, which clock signals. some operating modes to detect crosseven when an error is present in the is set separately with one of 11 funcovers in the signal paths. system tion modes. Range of applications
- • Use as an input module for a high• Use of multi-channel sensor appli• Connection of various switches and - **Note**
- er-order safety controller. Several incations with up to 8 secure inputs, sensors within the safety chain H- put modules can be used together which can be grouped and are suita• Output of an identifier coded by DIL The safety integrity level, Perforand these monitor mutually indeble for configuration with the help of switch in the connection block mance Level and category for the syspendent sensors 11 different function modes CPX-AB-ID-P tem as a whole correspond to that of the component in the safety chain with the lowest characteristic value.
- Application examples
- • Two-hand control device for starting • Operating mode selector switch with • Light curtain • End-position switch a function four positions • Acknowledge button with request • Protective door with two NO
- • Emergency stop switch for incidents • Rotary indexing table switches
Subject to change – 2023/10
d **Internet: www.festo.com/catalogue/...**
154
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, digital, PROFIsafe
## **General technical data**
**==> picture [523 x 403] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type CPX-F8DE-P<br>Number of inputs 8<br>Safety function Reliable detection and evaluation of input statuses<br>Max. address capacity Inputs [byte] 6<br>Outputs [byte] 7<br>Maximum cable length [m] 200<br>Max. power supply Per module [A] 3<br>Current consumption of module [mA] Typically 35 (power supply for electronics)<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 20.4 ... 28.8<br>Voltage drop per channel [V] 0.6<br>Residual ripple [Vss] 2 within voltage range<br>Galvanic isolation Channel – channel No<br>Input characteristics To IEC 61131-2, type 2<br>Switching logic Inputs PNP (positive switching)<br>Safety integrity level As per EN 62061 Reliable detection and evaluation of input statuses up to SIL CL3<br>As per EN 61508 Reliable detection and evaluation of input statuses up to SIL3<br>Performance Level As per ISO 13849 Reliable detection and evaluation of input statuses up to Cat 4 and PL e<br>Failure rate per hour (PFH) 1.0x 10 [-9]<br>Certificate issuing authority 01/205/5444.01/21<br>LED displays Group diagnostics 1<br>Channel diagnostics 8<br>Channel status 8<br>Failsafe protocol active 1<br>Diagnostics • Short circuit per channel<br>• Undervoltage<br>• Overvoltage<br>• Excessive temperature<br>• Crossover per channel<br>• Wire break per channel<br>• Communication<br>• Process data error<br>• Self-test<br>Control elements DIL switch<br>Degree of protection to EN 60529 Depending on connection block<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block and connection block) W x L x H [mm] 50 x 107 x 55<br>Product weight [g] 46<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
155
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, digital, PROFIsafe
**==> picture [524 x 159] intentionally omitted <==**
**----- Start of picture text -----**<br>
Materials<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Operating and environmental conditions<br>Ambient temperature [°C] –5 ... +50<br>Storage temperature [°C] –20 ... +70<br>CE marking (see declaration of conformity) [1)] To EU Machinery Directive<br>To EU EMC Directive<br>To EU RoHS Directive<br>UKCA marking (see declaration of conformity) [1)] To UK instructions for machines<br>To UK instructions for EMC<br>To UK RoHS instructions<br>Certification c UL us - Recognized (OL)<br>**----- End of picture text -----**<br>
- 1) Additional information at: www.festo.com/catalogue/... d Support/Downloads.
**==> picture [522 x 119] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection and display components<br>CPX-F8DE-P<br>2 [1] Channel-related status LEDs [3] Fail-safe protocol active (green)<br>(green) [4] Error LED (red, module error)<br>4 [2] Channel-related error LEDs (red)<br>1 3<br>**----- End of picture text -----**<br>
|**Combinations of bus nodes/control blocks with PROFIsafe input module**<br>Bus node/control block<br>Part no.<br>PROFIsafe input module<br>CPX-F8DE-P<br>CPX-FB13<br>**195740**<br>h|**Combinations of bus nodes/control blocks with PROFIsafe input module**<br>Bus node/control block<br>Part no.<br>PROFIsafe input module<br>CPX-F8DE-P<br>CPX-FB13<br>**195740**<br>h|**Combinations of bus nodes/control blocks with PROFIsafe input module**<br>Bus node/control block<br>Part no.<br>PROFIsafe input module<br>CPX-F8DE-P<br>CPX-FB13<br>**195740**<br>h|
|---|---|---|
|||CPX-F8DE-P<br>h|
|CPX-FB13|**195740**||
|CPX-FB43|**8110369**|h|
|CPX-M-FB44|**8110370**|h|
|CPX-M-FB45|**8110371**|h|
## - **Note** H-
The PROFIsafe input module CPXF8DE-P can only be integrated as of software release 21 or release 30 (in the case of CPX-FB13).
Subject to change – 2023/10
156
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, digital, PROFIsafe
**==> picture [523 x 607] intentionally omitted <==**
**----- Start of picture text -----**<br>
Combinations of connection blocks and PROFIsafe input module<br>Connection blocks Part no. PROFIsafe input module<br>CPX-F8DE-P<br>CPX-M-AB-4-M12X2-5POL 549367 h<br>CPX-M-AB-4-M12X2-5POL-T 2639560 h<br>CPX-AB-8-KL-4POL 195708 h<br>CPX-AB-ID-P 2639571 h<br>Pin allocation<br>Connection block inputs CPX-F8DE-P<br>CPX-M-AB-4-M12X2-5POL<br>X1.1: 24 VSEN X3.1: 24 VSEN<br>X1.2: Input x+1 X3.2: Input x+5<br>X1.3: 0 VSEN X3.3: 0 VSEN<br>X1.4: Input x X3.4: Input x+4<br>X1.5: FE X3.5: FE<br>X2.1: 24 VSEN X4.1: 24 VSEN<br>X2.2: Input x+3 X4.2: Input x+7<br>X2.3: 0 VSEN X4.3: 0 VSEN<br>X2.4: Input x+2 X4.4: Input x+6<br>X2.5: FE X4.5: FE<br>CPX-M-AB-4-M12X2-5POL-T<br>X1-T.1: 24 VSEN x X3-T.1: 24 VSEN x+4<br>X1-T.2: Input x+1 X3-T.2: Input x+5<br>X1-T.3: 0 VSEN X3-T.3: 0 VSEN<br>X1-T.4: Input x X3-T.4: Input x+4<br>X1-T.5: 24 VSEN x+1 X3-T.5: 24 VSEN x+5<br>X2-T.1: 24 VSEN x+2 X4-T.1: 24 VSEN x+6<br>X2-T.2: Input x+3 X4-T.2: Input x+7<br>X2-T.3: 0 VSEN X4-T.3: 0 VSEN<br>X2-T.4: Input x+2 X4-T.4: Input x+6<br>X2-T.5: 24 VSEN x+3 X4-T.5: 24 VSEN x+7<br>CPX-AB-8-KL-4POL<br>X1.0: 24 VSEN X5.0: 24 VSEN<br>X1 .0 .0 X5<br>.1 .1 X1.1: 0 VSEN X5.1: 0 VSEN<br>.2.3 .2.3 X1.2: Input x X5.2: Input x+4<br>.0 .0 X1.3: FE X5.3: FE<br>X2 .1.2 .1.2 X6 X2.0: 24 VSEN x X6.0: 24 VSEN x+4<br>.3.0 .3.0 X2.1: 24 VSEN x+1 X6.1: 24 VSEN x+5<br>X3 .1.2 .1.2 X7 X2.2: Input x+1 X6.2: Input x+5<br>.3 .3 X2.3: FE X6.3: FE<br>.0.1 .0.1 X3.0: 24 VSEN X7.0: 24 VSEN<br>X4 .2.3 .2.3 X8 X3.1: 0 VSEN X7.1: 0 VSEN<br>X3.2: Input x+2 X7.2: Input x+6<br>X3.3: FE X7.3: FE<br>X4.0: 24 VSEN x+2 X8.0: 24 VSEN x+6<br>X4.1: 24 VSEN x+3 X8.1: 24 VSEN x+7<br>X4.2: Input x+3 X8.2: Input x+7<br>X4.3: FE X8.3: FE<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
157
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, digital, PROFIsafe
## **General technical data**
**==> picture [524 x 113] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type CPX-AB-ID-P<br>Certificate issuing authority 01/205/5444.00/15<br>German Technical Control Board (TÜV) Rh. UK 01/205U/5444.00/22<br>Degree of protection to EN 60529 IP65<br>Housing material PA<br>PC<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Corrosion resistance class CRC [1)] 1<br>Product weight [g] 57<br>**----- End of picture text -----**<br>
1) Additional information: www.festo.com/x/topic/kbk
## **Combinations of interlinking blocks and PROFIsafe input module**
**==> picture [524 x 306] intentionally omitted <==**
**----- Start of picture text -----**<br>
Interlinking blocks Part no. PROFIsafe input module<br>CPX-F8DE-P<br>CPX-GE-EV-S 195746 –<br>CPX-GE-EV-S-VL 8022170 –<br>CPX-GE-EV-S-7/8-4POL 541248 –<br>CPX-GE-EV-S-7/8-5POL 541244 –<br>CPX-GE-EV-S-7/8-5POL-VL 8022172 –<br>CPX-M-GE-EV-S-7/8-CIP-4P 568956 h<br>CPX-M-GE-EV-S-7/8-5POL 550208 h<br>CPX-M-GE-EV-S-7/8-5POL-VL 8022165 h<br>CPX-M-GE-EV-S-M12-5POL 8098392 h<br>CPX-M-GE-EV-S-PP-5POL 563057 h<br>CPX-GE-EV 195742 –<br>CPX-M-GE-EV 550206 h<br>CPX-M-GE-EV-FVO 567806 –<br>CPX-GE-EV-Z 195744 –<br>CPX-GE-EV-Z-VL 8022166 –<br>CPX-GE-EV-Z-7/8-4POL 541250 –<br>CPX-GE-EV-Z-7/8-5POL 541246 –<br>CPX-GE-EV-Z-7/8-5POL-VL 8022173 –<br>CPX-M-GE-EV-Z-7/8-5POL 550210 h<br>CPX-M-GE-EV-Z-7/8-5POL-VL 8022158 h<br>CPX-M-GE-EV-Z-PP-5POL 563058 h<br>CPX-GE-EV-V 533577 –<br>CPX-GE-EV-V-VL 8022171 –<br>CPX-GE-EV-V-7/8-4POL 541252 –<br>CPX-M-GE-EV-W-M12-5POL 8098391 h<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
158
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, digital, PROFIsafe
**==> picture [523 x 484] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Description Part no. Type<br>PROFIsafe input module<br>8 digital inputs, positive logic (PNP), for reliable detection and evaluation of input statuses 2597424 CPX-F8DE-P<br>Connection block<br>Plastic Spring-loaded terminal, 32-pin 195708 CPX-AB-8-KL-4POL<br>8-way DIL switch 2639571 CPX-AB-ID-P<br>Metal 4x socket M12, 5-pin Unpulsed sensor 549367 CPX-M-AB-4-M12X2-5POL<br>supply<br>Pulsed sensor sup- 2639560 CPX-M-AB-4-M12X2-5POL-T<br>ply<br>Distributor<br>Modular system for all types of sensor/actuator distributor – NEDY- ...<br>a Internet: nedy<br>1x plug M12, 4-pin 2x socket M12, 5-pin 8005310 NEDY-L2R1-V1-M12G5-N-M12G4<br>Plug<br>Plug M12, PG7 18666 SEA-GS-7<br>M12, PG7, 4-pin for cable @ 2.5 mm 192008 SEA-4GS-7-2.5<br>M12, PG9 18778 SEA-GS-9<br>M12 for 2 cables 18779 SEA-GS-11-DUO<br>M12 for 2 cables, 5-pin 192010 SEA-5GS-11-DUO<br>M12, 5-pin 175487 SEA-M12-5GS-PG7<br>Connecting cable<br>Modular system for a choice of connecting cables – NEBU- ...<br>a Internet: nebu<br>User documentation<br>User documentation for PROFIsafe input module German 8035496 CPX-F8DE-P-DE<br>English 8035497 CPX-F8DE-P-EN<br>Spanish 8035498 CPX-F8DE-P-ES<br>French 8035499 CPX-F8DE-P-FR<br>Italian 8035500 CPX-F8DE-P-IT<br>Chinese 8035501 CPX-F8DE-P-ZH<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
159
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Input module, digital, 16 inputs
## **Function**
## **Area of application**
Digital input modules enable the con• Input modules for 24 V DC sensor nection of two-wire and three-wire sensupply voltage sors (proximity switches, inductive or • PNP logic capacitive sensors, etc.). • Module features can be parameterDepending on the connection block seised lected, the module supports various • The input module receives the supconnection concepts with different ply voltage for the electronics and numbers of sockets (single or double the sensors from the interlinking allocation). block
- Module protection and diagnostics through integrated electronic protection
## **General technical data**
Type CPX-16DE CPX-M-16DE-D CPX-L-16DE a Number of inputs 16 16 16 ~~RO~~ Max. residual current of inputs per module [A] 1.8 1.8 1.8 Intrinsic current consumption at operating voltage [mA] Typically 15 Typically 34 Typically 15 Fuse protection Internal electronic fuse per Internal electronic fuse per Internal electronic fuse per module channel pair, additional module ~~eeOO~~ Nominal operating voltage [V DC] 24 ~~ee~~ safet24 y fuse ~~ee~~ 24 ~~OO~~ Operating voltage range [V DC] 18 ... 30 18 ... 30 18 ... 30 Galvanic isolation Channel – channel No No No ~~a~~ Channel – internal bus ~~a~~ No No No Switching level Signal 0 [V DC] š 5 š 5 š 5 ~~eH~~ Signal 1 [V DC] ~~es~~ › 11 › 11 › 15 ~~RC~~ Input debounce time [ms] 3 (0.1 ms, 10 ms, 20 ms parameterisable) ~~OG~~ Input characteristic IEC 1131-T2 IEC 1131-T2 IEC 1131-T2, type 01 ~~RO~~ Switching logic Positive logic (PNP) Positive logic (PNP) Positive logic (PNP) LED displays Group diagnostics ~~ee~~ 1 1 1 Channel diagnostics – 16 – ~~a~~ Channel status ~~ee~~ 16 16 16 ~~a~~ Diagnostics Short circuit/overload per channel Parameterisation • Module monitoring • Behaviour after short circuit • Input debounce time • Signal extension time Degree of protection to EN 60529 Depending on connection Depending on connection IP20 ~~ee~~ block block Temperature range Operation [°C] –5 ... +50 –5 ... +50 –5 ... +50 ~~ee~~ Storage/transport [°C] ~~Rs~~ –20 ... +70 –20 ... +70 –20 ... +70 – – ~~HH OG~~ Certification c UL us - Listed (OL) ~~OO~~ Materials Reinforced PA, PC Reinforced PA, PC PA-reinforced ~~OO~~ Note on materials – – RoHS-compliant ~~OO~~ PWIS conformity VDMA24364-B2-L VDMA24364-B2-L VDMA24364-B2-L ~~RC~~ Grid dimension [mm] 50 50 50 ~~OO~~ Dimensions (including interlinking block and connection block) W x L x H [mm] 50 x 107 x 50 50 x 107 x 50 50 x 107 x 41 ~~a~~ Product weight [g] 41 46 167
Subject to change – 2023/10
160
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, digital, 16 inputs
**==> picture [523 x 270] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection and display components<br>CPX-16DE CPX-M-16DE-D<br>1 1 [1] Status LEDs (green): for allocation [1] Common status LEDs (green)/error<br>2<br>to the inputs a pin allocation of LEDs (red) for each input signal<br>2 the module [2] Error LED (red, module error)<br>[2] Error LED (red, module error)<br>1 1<br>1<br>CPX-L-16DE<br>2 [1] Status LEDs (green) for each input<br>signal<br>[2] Error LED (red, module error)<br>1 1<br>**----- End of picture text -----**<br>
**==> picture [258 x 120] intentionally omitted <==**
**----- Start of picture text -----**<br>
CPX-M-16DE-D<br>[1] Common status LEDs (green)/error<br>2<br>LEDs (red) for each input signal<br>[2] Error LED (red, module error)<br>1<br>**----- End of picture text -----**<br>
|**Combinations of connection blocks and digital input modules**<br>Connection blocks<br>Part no.<br>CPX-AB-8-M8X2-4POL<br>**541256**|**Combinations of connection blocks and digital input modules**<br>Connection blocks<br>Part no.<br>CPX-AB-8-M8X2-4POL<br>**541256**|Digital input modules|Digital input modules|Digital input modules|
|---|---|---|---|---|
|||CPX-16DE<br>h|CPX-M-16DE-D<br>–|CPX-L-16DE<br>–|
|CPX-AB-8-M12X2-5POL|**3606900**|–|h|–|
|CPX-AB-8-KL-4POL|**195708**|h|–|–|
|CPX-AB-1-SUB-BU-25POL|**525676**|h|–|–|
|CPX-M-AB-8-M12X2-5POL|**549335**|–|h|–|
2023/10 – Subject to change
161
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, digital, 16 inputs
## **Pin allocation**
**==> picture [524 x 611] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection block inputs CPX-16DE<br>CPX-AB-8-M8x2-4POL<br>X1.1: 24 VSEN X5.1: 24 VSEN<br>X1.2: Input x+1 X5.2: Input x+9<br>X1.3: 0 VSEN X5.3: 0 VSEN<br>X1.4: Input x X5.4: Input x+8<br>X2.1: 24 VSEN X6.1: 24 VSEN<br>X2.2: Input x+3 X6.2: Input x+11<br>X2.3: 0 VSEN X6.3: 0 VSEN<br>X2.4: Input x+2 X6.4: Input x+10<br>X3.1: 24 VSEN X7.1: 24 VSEN<br>X3.2: Input x+5 X7.2: Input x+13<br>X3.3: 0 VSEN X7.3: 0 VSEN<br>X3.4: Input x+4 X7.4: Input x+12<br>X4.1: 24 VSEN X8.1: 24 VSEN<br>X4.2: Input x+7 X8.1: Input x+15<br>X4.3: 0 VSEN X8.3: 0 VSEN<br>X4.4: Input x+6 X8.4: Input x+14<br>CPX-AB-8-KL-4POL<br>X1.0: Input x+8 X5.0: Input x+12<br>X1 .0 .0 X5<br>.1 .1 X1.1: 24 VSEN X5.1: 0 VSEN<br>.2.3 .2.3 X1.2: Input x X5.2: Input x+4<br>.0 .0 X1.3: FE X5.3: FE<br>X2 .1.2 .1.2 X6 X2.0: Input x+9 X6.0: Input x+13<br>.3.0 .3.0 X2.1: 24 VSEN X6.1: 0 VSEN<br>X3 .1.2 .1.2 X7 X2.2: Input x+1 X6.2: Input x+5<br>.3 .3 X2.3: FE X6.3: FE<br>.0.1 .0.1 X3.0: Input x+10 X7.0: Input x+14<br>X4 .2.3 .2.3 X8 X3.1: 24 VSEN X7.1: 0 VSEN<br>X3.2: Input x+2 X7.2: Input x+6<br>X3.3: FE X7.3: FE<br>X4.0: Input x+11 X8.0: Input x+15<br>X4.1: 24 VSEN X8.1: 0 VSEN<br>X4.2: Input x+3 X8.2: Input x+7<br>X4.3: FE X8.3: FE<br>CPX-AB-1-SUB-BU-25POL<br>1: Input x 14: Input x+4<br>2: Input x+1 15: Input x+5<br>3: Input x+2 16: Input x+6<br>4: Input x+3 17: Input x+7<br>5: Input x+9 18: Input x+12<br>6: 24 VSEN 19: Input x+13<br>7: Input x+11 20: Input x+14<br>8: 24 VSEN 21: Input x+15<br>9: Input x+8 22: 0 VSEN<br>10: Input x+10 23: 0 VSEN<br>11: 24 VSEN 24: 0 VSEN<br>12: 24 VSEN 25: FE<br>13: FE Housing: FE<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
162
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, digital, 16 inputs
## **Pin allocation**
**==> picture [523 x 274] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection block inputs CPX-M-16DE-D<br>CPX-M-AB-8-M12X2-5POL and CPX-AB-8-M12X2-5POL<br>X1.1: 24 VSx X5.1: 24 VSx+8<br>X1.2: Input x+1 X5.2: Input x+9<br>X1.3: 0 VSx X5.3: 0 VSx+8<br>X1.4: Input x X5.4: Input x+8<br>X1.5: FE X5.5: FE<br>X2.1: 24 VSx+2 X6.1: 24 VSx+10<br>X2.2: Input x+3 X6.2: Input x+11<br>X2.3: 0 VSx+2 X6.3: 0 VSx+10<br>X2.4: Input x+2 X6.4: Input x+10<br>X2.5: FE X6.5: FE<br>X3.1: 24 VSx+4 X7.1: 24 VSx+12<br>X3.2: Input x+5 X7.2: Input x+13<br>X3.3: 0 VSx+4 X7.3: 0 VSx+12<br>X3.4: Input x+4 X7.4: Input x+12<br>X3.5: FE X7.5: FE<br>X4.1: 24 VSx+6 X8.1: 24 VSx+14<br>X4.2: Input x+7 X8.2: Input x+15<br>X4.3: 0 VSx+6 X8.3: 0 VSx+14<br>X4.4: Input x+6 X8.4: Input x+14<br>X4.5: FE X8.5: FE<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
163
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, digital, 16 inputs
## **Pin allocation**
**==> picture [523 x 321] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection block inputs CPX-L-16DE<br>X1.0: 24 VSEN X9.0: 24 VSEN<br>X1.1: Input x X9.1: Input x+8<br>X1.2: 0 VSEN X9.2: 0 VSEN<br>X2.0: 24 VSEN X10.0: 24 VSEN<br>X2.1: Input x+1 X10.1: Input x+9<br>X2.2: 0 VSEN X10.2: 0 VSEN<br>X3.0: 24 VSEN X11.0: 24 VSEN<br>X3.1: Input x+2 X11.1: Input x+10<br>X3.2: 0 VSEN X11.2: 0 VSEN<br>X4.0: 24 VSEN X12.0: 24 VSEN<br>X4.1: Input x+3 X12.1: Input x+11<br>X4.2: 0 VSEN X12.2: 0 VSEN<br>X5.0: 24 VSEN X13.0: 24 VSEN<br>X5.1: Input x+4 X13.1: Input x+12<br>X5.2: 0 VSEN X13.2: 0 VSEN<br>X6.0: 24 VSEN X14.0: 24 VSEN<br>X6.1: Input x+5 X14.1: Input x+13<br>X6.2: 0 VSEN X14.2: 0 VSEN<br>X7.0: 24 VSEN X15.0: 24 VSEN<br>X7.1: Input x+6 X15.1: Input x+14<br>X7.2: 0 VSEN X15.2: 0 VSEN<br>X8.0: 24 VSEN X16.0: 24 VSEN<br>X8.1: Input x+7 X16.1: Input x+15<br>X8.2: 0 VSEN X16.2: 0 VSEN<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
164
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, digital, 16 inputs
## **Ordering data**
**==> picture [523 x 610] intentionally omitted <==**
**----- Start of picture text -----**<br>
Designation Part no. Type<br>Input module, digital<br>16 digital inputs, internal electronic fuse per module 543815 CPX-16DE<br>16 digital inputs, internal electronic fuse per channel pair, for CPX in metal 550202 CPX-M-16DE-D<br>16 digital inputs, internal electronic fuse per module, for CPX in plastic, including interlinking block 572606 CPX-L-16DE-16-KL-3POL<br>and connection block with spring-loaded terminals<br>Connection block<br>Plastic 8x socket M8, 4-pin 541256 CPX-AB-8-M8X2-4POL<br>8x socket M12, 5-pin 3606900 CPX-AB-8-M12X2-5POL<br>Spring-loaded terminal, 32-pin 195708 CPX-AB-8-KL-4POL<br>1x socket, Sub-D, 25-pin 525676 CPX-AB-1-SUB-BU-25POL<br>Metal 8x socket M12, 5-pin 549335 CPX-M-AB-8-M12X2-5POL<br>Distributor<br>Modular system for all types of sensor/actuator distributor – NEDY- ...<br>a Internet: nedy<br>1x plug M8, 4-pin 2x socket M8, 3-pin 8005312 NEDY-L2R1-V1-M8G3-N-M8G4<br>Plug<br>Plug M8, 3-pin Solderable 18696 SEA-GS-M8<br>Screw-in 192009 SEA-3GS-M8-S<br>Sub-D plug, 25-pin 527522 SD-SUB-D-ST25<br>Connecting cable<br>Connecting cable M8-M8 0.5 m 541346 NEBU-M8G3-K-0.5-M8G3<br>1.0 m 541347 NEBU-M8G3-K-1-M8G3<br>2.5 m 541348 NEBU-M8G3-K-2.5-M8G3<br>5.0 m 541349 NEBU-M8G3-K-5-M8G3<br>Modular system for a choice of connecting cables – NEBU- ...<br>a Internet: nebu<br>Cover<br>Cover for CPX-AB-8-KL-4POL (IP65, IP67) 538219 AK-8KL<br>• 8 cable through feeds M9<br>• 1 cable through feed for multi-pin plug<br>Fittings kit 538220 VG-K-M9<br>User documentation<br>User documentation German 526439 P.BE-CPX-EA-DE<br>English 526440 P.BE-CPX-EA-EN<br>Spanish 526441 P.BE-CPX-EA-ES<br>French 526442 P.BE-CPX-EA-FR<br>Italian 526443 P.BE-CPX-EA-IT<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
165
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Output module, digital
## **Function**
## **Area of application**
Digital outputs control actuators such • Output module for 24 V DC supply as individual valves, hydraulic valves, voltage heating controllers and many more. • PNP logic Separate circuits are created using an • Module features can be parameteradditional supply. Parallel connection ised of the outputs of a module enables • The output module receives the voltconsuming devices to be controlled age supply for the electronics and with up to 4 A. the outputs from the interlinking block
- Module protection and diagnostics through integrated electronic protection in each channel
## **General technical data**
Type CPX-4DA CPX-8DA CPX-8DA-H a Number of outputs 4 8 8 Max. power supply Per module [A] 4 8.4 Per channel [A] 1 (24 W lamp load, 4 chan0.5 (12 W lamp load, 8 2.1 (50 W lamp load), per nels can be connected in channels can be connected channel pair ~~es~~ parallel) ~~ee~~ in parallel) ~~ee ee~~ Fuse protection (short circuit) Internal electronic fuse per channel ~~Ce~~ Module current consumption (power supply for electronics) [mA] Typically 16 Typically 34 Operating voltage Nominal value [V DC] 24 Permissible range [V DC] 18 ... 30 ~~es ei~~ Galvanic isolation Channel – channel No ~~pO,~~ Channel – internal bus Yes, with intermediate supply ~~GO~~ Output characteristic Based on IEC 1131-2 Switching logic Positive logic (PNP) ~~rs~~ LED displays Group diagnostics 1 1 1 Channel diagnostics 4 8 8 ~~a~~ Channel status 4 8 8 Diagnostics • Short circuit/overload, channel x ~~Se~~ • Undervoltage of outputs Parameterisation • Module monitoring • Behaviour after short circuit • Fail-safe channel x • Forcing channel x • Idle mode channel x ~~GO~~ Degree of protection to EN 60529 Depending on connection block Temperature range Operation [°C] –5 ... +50 ~~oO~~ Storage/transport [°C] –20 ... +70 ~~GO~~ Materials Reinforced PA, PC ~~GO~~ PWIS conformity VDMA24364-B2-L ~~GO~~ Grid dimension [mm] 50 Dimensions (including interlinking block and connection block) W x L x H [mm] 50 x 107 x 50 ~~shes~~ Product weight [g] 42 49 48
Subject to change – 2023/10
166
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Output module, digital
|**Connection and display components**|**Connection and display components**|**Connection and display components**|**Connection and display components**||
|---|---|---|---|---|
|CPX-4DA|||CPX-8DA<br>3<br>~~1~~<br>~~1~~<br>~~2~~<br>~~2~~|3<br>[1] Status LEDs (yellow): for alloca-<br>tion to outputsapin allocation<br>of the module<br>[2] Channel-related error LEDs (red)<br>[3] Error LED (red, module error)|
||~~1~~|~~2~~|||
||||||
||||||
**==> picture [523 x 315] intentionally omitted <==**
**----- Start of picture text -----**<br>
Combinations of connection block and digital output module<br>Connection blocks Part no. Digital output module<br>CPX-4DA CPX-8DA CPX-8DA-H<br>CPX-AB-8-M8-3POL 195706 h h –<br>CPX-AB-8-M8X2-4POL 541256 h h h<br>CPX-AB-4-M12X2-5POL 195704 h h –<br>CPX-AB-4-M12X2-5POL-R 541254 h h h<br>CPX-AB-8-KL-4POL 195708 h h h<br>CPX-AB-1-SUB-BU-25POL 525676 h h h<br>CPX-M-AB-4-M12X2-5POL 549367 h h h<br>Pin allocation<br>Connection block outputs CPX-4DA CPX-8DA<br>CPX-AB-8-M8-3POL<br>X1.1: n.c. X5.1: n.c. X1.1: n.c. X5.1: n.c.<br>X1.3: 0 VOUT X5.3: 0 VOUT X1.3: 0 VOUT X5.3: 0 VOUT<br>X1.4: Output x X5.4: Output x+2 X1.4: Output x X5.4: Output x+4<br>X2.1: n.c. X6.1: n.c. X2.1: n.c. X6.1: n.c.<br>X2.3: 0 VOUT X6.3: 0 VOUT X2.3: 0 VOUT X6.3: 0 VOUT<br>X2.4: Output x+1 X6.4: Output x+3 X2.4: Output x+1 X6.4: Output x+5<br>X3.1: n.c. X7.1: n.c. X3.1: n.c. X7.1: n.c.<br>X3.3: 0 VOUT X7.3: 0 VOUT X3.3: 0 VOUT X7.3: 0 VOUT<br>X3.4: Output x+1 X7.4: Output x+3 X3.4: Output x+2 X7.4: Output x+6<br>X4.1: n.c. X8.1: n.c. X4.1: n.c. X8.1: n.c.<br>X4.3: 0 VOUT X8.3: 0 VOUT X4.3: 0 VOUT X8.3: 0 VOUT<br>X4.4: n.c. X8.4: n.c. X4.4: Output x+3 X8.4: Output x+7<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
167
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Output module, digital
## **Pin allocation**
**==> picture [524 x 583] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection block outputs CPX-4DA CPX-8DA and CPX-8DA-H<br>CPX-AB-8-M8X2-4POL<br>X1.1: 0 VOUT X5.1: 0 VOUT X1.1: 0 VOUT X5.1: 0 VOUT<br>X1.2: Output x+1 X5.2: n.c. X1.2: Output x+1 X5.2: n.c.<br>X1.3: 0 VOUT X5.3: 0 VOUT X1.3: 0 VOUT X5.3: 0 VOUT<br>X1.4: Output x X5.4: n.c. X1.4: Output x X5.4: n.c.<br>X2.1: 0 VOUT X6.1: 0 VOUT X2.1: 0 VOUT X6.1: 0 VOUT<br>X2.2: n.c. X6.2: n.c. X2.2: Output x+3 X6.2: n.c.<br>X2.3: 0 VOUT X6.3: 0 VOUT X2.3: 0 VOUT X6.3: 0 VOUT<br>X2.4: Output x+1 X6.4: n.c. X2.4: Output x+2 X6.4: n.c.<br>X3.1: 0 VOUT X7.1: 0 VOUT X3.1: 0 VOUT X7.1: 0 VOUT<br>X3.2: Output x+3 X7.2: n.c. X3.2: Output x+5 X7.2: n.c.<br>X3.3: 0 VOUT X7.3: 0 VOUT X3.3: 0 VOUT X7.3: 0 VOUT<br>X3.4: Output x+2 X7.4: n.c. X3.4: Output x+4 X7.4: n.c.<br>X4.1: 0 VOUT X8.1: 0 VOUT x+1 X4.1: 0 VOUT X8.1: 0 VOUT<br>X4.2: n.c. X8.2: n.c. X4.2: Output x+7 X8.2: n.c.<br>X4.3: 0 VOUT X8.3: 0 VOUT x+3 X4.3: 0 VOUT X8.3: 0 VOUT<br>X4.4: Output x+3 X8.4: n.c. X4.4: Output x+6 X8.4: n.c.<br>CPX-AB-4-M12X2-5POL [1)] and CPX-AB-4-M12X2-5POL-R [2)]<br>X1.1: n.c. X3.1: n.c. X1.1: n.c. X3.1: n.c.<br>X1.2: Output x+1 X3.2: Output x+3 X1.2: Output x+1 X3.2: Output x+5<br>X1.3: 0 VOUT X3.3: 0 VOUT X1.3: 0 VOUT X3.3: 0 VOUT<br>X1.4: Output x X3.4: Output x+2 X1.4: Output x X3.4: Output x+4<br>X1.5: FE X3.5: FE X1.5: FE X3.5: FE<br>X2.1: n.c. X4.1: n.c. X2.1: n.c. X4.1: n.c.<br>X2.2: n.c. X4.2: n.c. X2.2: Output x+3 X4.2: Output x+7<br>X2.3: 0 VOUT X4.3: 0 VOUT X2.3: 0 VOUT X4.3: 0 VOUT<br>X2.4: Output x+1 X4.4: Output x+3 X2.4: Output x+2 X4.4: Output x+6<br>X2.5: FE X4.5: FE X2.5: FE X4.5: FE<br>CPX-AB-8-KL-4POL<br>X1.0: n.c. X5.0: n.c. X1.0: n.c. X5.0: n.c.<br>X1 .0 .0 X5<br>.1 .1 X1.1: 0 VOUT X5.1: 0 VOUT X1.1: 0 VOUT X5.1: 0 VOUT<br>.2.3 .2.3 X1.2: Output x X5.2: Output x+2 X1.2: Output x X5.2: Output x+4<br>.0 .0 X1.3: FE X5.3: FE X1.3: FE X5.3: FE<br>X2 .1.2 .1.2 X6 X2.0: n.c. X6.0: n.c. X2.0: n.c. X6.0: n.c.<br>.3.0 .3.0 X2.1: 0 VOUT X6.1: 0 VOUT X2.1: 0 VOUT X6.1: 0 VOUT<br>X3 .1.2 .1.2 X7 X2.2: Output x+1 X6.2: Output x+3 X2.2: Output x+1 X6.2: Output x+5<br>.3 .3 X2.3: FE X6.3: FE X2.3: FE X6.3: FE<br>.0 .0 X3.0: n.c. X7.0: n.c. X3.0: n.c. X7.0: n.c.<br>.1 .1<br>X4 .2.3 .2.3 X8 X3.1: 0 VOUT X7.1: 0 VOUT X3.1: 0 VOUT X7.1: 0 VOUT<br>X3.2: Output x+1 X7.2: Output x+3 X3.2: Output x+2 X7.2: Output x+6<br>X3.3: FE X7.3: FE X3.3: FE X7.3: FE<br>X4.0: n.c. X8.0: n.c. X4.0: n.c. X8.0: n.c.<br>X4.1: 0 VOUT X8.1: 0 VOUT X4.1: 0 VOUT X8.1: 0 VOUT<br>X4.2: n.c. X8.2: n.c. X4.2: Output x+3 X8.2: Output x+7<br>X4.3: FE X8.3: FE X4.3: FE X8.3: FE<br>**----- End of picture text -----**<br>
- 1) Not suitable for CPX-8DA-H.
- 2) Speedcon quick lock, additional shielding on metal thread
Subject to change – 2023/10
168
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Output module, digital
## **Pin allocation**
**==> picture [523 x 184] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection block outputs CPX-4DA CPX-8DA and CPX-8DA-H<br>CPX-AB-1-SUB-BU-25POL<br>1: Output x 14: Output x+2 1: Output x 14: Output x+4<br>2: Output x+1 15: Output x+3 2: Output x+1 15: Output x+5<br>3: Output x+1 16: Output x+3 3: Output x+2 16: Output x+6<br>4: n.c. 17: n.c. 4: Output x+3 17: Output x+7<br>5: n.c. 18: n.c. 5: n.c. 18: n.c.<br>6: 0 VOUT 19: n.c. 6: 0 VOUT 19: n.c.<br>7: n.c. 20: n.c. 7: n.c. 20: n.c.<br>8: 0 VOUT 21: n.c. 8: 0 VOUT 21: n.c.<br>9: n.c. 22: 0 VOUT 9: n.c. 22: 0 VOUT<br>10: n.c. 23: 0 VOUT 10: n.c. 23: 0 VOUT<br>11: 0 VOUT 24: 0 VOUT 11: 0 VOUT 24: 0 VOUT<br>12: 0 VOUT 25: FE 12: 0 VOUT 25: FE<br>13: FE Housing: FE 13: FE Housing: FE<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
169
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Output module, digital
## **Ordering data**
**==> picture [524 x 503] intentionally omitted <==**
**----- Start of picture text -----**<br>
Designation Part no. Type<br>Output module, digital<br>4 digital outputs, power supply 1 A per channel 195754 CPX-4DA<br>8 digital outputs, power supply 0.5 A per channel 541482 CPX-8DA<br>8 digital outputs, power supply 2.1 A per channel pair 550204 CPX-8DA-H<br>Connection block<br>Plastic 8x socket M8, 3-pin 195706 CPX-AB-8-M8-3POL<br>8x socket M8, 4-pin 541256 CPX-AB-8-M8X2-4POL<br>4x socket M12, 5-pin 195704 CPX-AB-4-M12X2-5POL<br>4x socket, M12 with quick-lock technology, 5-pin 541254 CPX-AB-4-M12X2-5POL-R<br>Spring-loaded terminal, 32-pin 195708 CPX-AB-8-KL-4POL<br>1x socket, Sub-D, 25-pin 525676 CPX-AB-1-SUB-BU-25POL<br>Metal 4x socket M12, 5-pin 549367 CPX-M-AB-4-M12X2-5POL<br>Distributor<br>Modular system for all types of sensor/actuator distributor – NEDY- ...<br>a Internet: nedy<br>1x plug M8, 4-pin 2x socket M8, 3-pin 8005312 NEDY-L2R1-V1-M8G3-N-M8G4<br>1x plug M12, 4-pin 2x socket M8, 3-pin 8005311 NEDY-L2R1-V1-M8G3-N-M12G4<br>2x socket M12, 5-pin 8005310 NEDY-L2R1-V1-M12G5-N-M12G4<br>Plug<br>Plug M8 3-pin Solderable 18696 SEA-GS-M8<br>Screw-in 192009 SEA-3GS-M8-S<br>M12, PG7 18666 SEA-GS-7<br>M12, PG7, 4-pin for cable @ 2.5 mm 192008 SEA-4GS-7-2.5<br>M12, PG9 18778 SEA-GS-9<br>M12 for 2 cables 18779 SEA-GS-11-DUO<br>M12 for 2 cables, 5-pin 192010 SEA-5GS-11-DUO<br>M12, 5-pin 175487 SEA-M12-5GS-PG7<br>Sub-D plug, 25-pin 527522 SD-SUB-D-ST25<br>Connecting cable<br>Connecting cable M8-M8 0.5 m 541346 NEBU-M8G3-K-0.5-M8G3<br>1.0 m 541347 NEBU-M8G3-K-1-M8G3<br>2.5 m 541348 NEBU-M8G3-K-2.5-M8G3<br>5.0 m 541349 NEBU-M8G3-K-5-M8G3<br>Modular system for a choice of connecting cables – NEBU- ...<br>a Internet: nebu<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
170
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Output module, digital
**==> picture [523 x 226] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>Cover<br>Cover for CPX-AB-8-KL-4POL (IP65, IP67) 538219 AK-8KL<br>• 8 cable through feeds M9<br>• 1 cable through feed for multi-pin plug<br>Fittings kit 538220 VG-K-M9<br>Screening plate<br>Screening plate for M12 connections 526184 CPX-AB-S-4-M12<br>User documentation<br>User documentation German 526439 P.BE-CPX-EA-DE<br>English 526440 P.BE-CPX-EA-EN<br>Spanish 526441 P.BE-CPX-EA-ES<br>French 526442 P.BE-CPX-EA-FR<br>Italian 526443 P.BE-CPX-EA-IT<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
171
Terminal CPX
## Data sheet – Input/output module, digital
## **Area of application**
- Digital multi I/O module for 24 V DC supply voltage
- Digital multi I/O module for 24 V DC • The outputs receive the voltage supsupply voltage ply for the electronics and the out-
- • Supports connection blocks with puts from the interlinking block Sub-D, terminal connection and • Module protection and diagnostics M12 connection (8-pin) through integrated electronic fuse
- Module protection and diagnostics through integrated electronic fuse protection for the sensor power supply and integrated electronic fuse protection in each output channel
- As CPX-L with connection via spring-loaded terminals
- Module features can be parameterised
- The inputs receive the voltage supply for the electronics and the sensors from the interlinking block
## **General technical data**
|• Module features can be parameter-<br>ised<br>• The inputs receive the voltage sup-<br>ply for the electronics and the sen-<br>sors from the interlinking block<br>protection in each output channel|• Module features can be parameter-<br>ised<br>• The inputs receive the voltage sup-<br>ply for the electronics and the sen-<br>sors from the interlinking block<br>protection in each output channel|• Module features can be parameter-<br>ised<br>• The inputs receive the voltage sup-<br>ply for the electronics and the sen-<br>sors from the interlinking block<br>protection in each output channel|
|---|---|---|
|**General technical data**<br>Type<br>CPX-8DE-8DA<br>CPX-L-8DE-8DA<br>Number<br>Inputs<br>8<br>8<br>Outputs<br>8<br>8<br>~~Ta~~<br>~~ee~~|||
||8<br>~~Ta~~<br>~~ee~~|8<br>~~Ta~~<br>~~ee~~|
|Max. power supply<br>Per module<br>Sensor supply<br>[A]<br>Outputs<br>[A]<br>~~Ta~~<br>~~to~~|0.7<br>~~Ta~~<br>~~ee~~<br>~~to~~|1.8<br>~~Ta~~<br>~~ee~~<br>~~to~~|
||4<br>~~to~~<br>~~ee~~|2<br>~~to~~<br>~~ee~~|
|Max. power supply per channel<br>[A]|0.5 (12 W lamp load, channels A0 ... A03<br>can be connected inparallel to A4 ... A7)|0.25 (6 W lamp load)|
|Fuseprotection (short circuit)<br>~~RC~~|Internal electronic fuseper channel<br>~~RC~~||
|Intrinsic current consumption at nominal operatingvoltage<br>[mA]<br>~~RC~~<br>~~OO~~|Typically22<br>~~RC~~<br>~~OO~~|Typically15<br>~~RC~~<br>~~OO~~|
|Operating voltage<br>Nominal value<br>[V DC]<br>Permissible range<br>[V DC]<br>~~OO~~<br>~~oo~~|24<br>~~OO~~<br>~~oo~~|24<br>~~OO~~<br>~~oo~~|
||18 ... 30<br>~~oo~~<br>~~ee~~<br>~~TTT~~<br>~~to~~|18 ... 30<br>~~oo~~<br>~~ee~~<br>~~to~~|
|Galvanic isolation, inputs<br>Channel – channel<br>Channel – internal bus<br>~~oo~~<br>~~I~~|No<br>~~oo~~<br>~~I~~<br>~~TTT~~<br>~~to~~|No<br>~~oo~~<br>~~I~~<br>~~to~~|
||No<br>~~I~~<br>~~TTT~~<br>~~to~~<br>~~ee~~|No<br>~~I~~<br>~~to~~<br>~~ee~~|
|Galvanic isolation, outputs<br>Channel – channel<br>Channel – internal bus<br>~~———————~~|No<br>~~TTT~~<br>~~to~~<br>~~———————~~|No<br>~~to~~<br>~~———————~~|
||Yes, with intermediate supply<br>~~———————~~<br>~~a~~|No<br>~~———————~~<br>~~a~~|
|Characteristic curve<br>Inputs<br>Outputs<br>~~————————~~|IEC 1131-T2<br>~~———————~~|IEC 1131-T2, type 01<br>~~———————~~|
||IEC 1131-T2<br>~~———————~~<br>~~Re~~|IEC 1131-T2<br>~~———————~~<br>~~Re~~|
|Switching level, inputs<br>Signal 0<br>[V DC]<br>Signal 1<br>[V DC]<br>~~————————~~|š5<br>~~———————~~<br>~~Re~~|š5<br>~~———————~~<br>~~Re~~|
||›11<br>~~es~~|›15<br>~~es~~|
|Input debounce time<br>[ms]<br>~~RO~~|3 (0.1 ms, 10 ms, 20 msparameterisable)<br>~~RO~~||
|Switchinglogic<br>~~CO~~|Positive logic (PNP)<br>~~CO~~|Positive logic (PNP)<br>~~CO~~|
|LED displays<br>Groupdiagnostics<br>Channel diagnostics<br>Channel status<br>~~ET~~|1<br>~~ET~~|1<br>~~ET~~|
||–<br>~~ET~~<br>~~Re~~|–<br>~~ET~~<br>~~Re~~|
||16<br>~~ET~~<br>~~Re~~<br>~~a~~|16<br>~~ET~~<br>~~Re~~<br>~~a~~|
|Diagnostics<br>~~ET~~|• Short circuit/overload per channel<br>• Undervoltage of outputs<br>~~ET~~<br>~~a~~||
|Parameterisation|• Input debounce time<br>• Failsafe per channel<br>• Forcing per channel<br>• Idle mode per channel<br>• Signal extension time<br>• Module monitoring<br>• Behaviour after short circuit||
|Degree ofprotection to EN 60529<br>~~GO~~|Dependingon connection block<br>~~GO~~|IP20<br>~~GO~~|
|Temperature range<br>Operation<br>[°C]<br>Storage/transport<br>[°C]<br>~~ena~~|–5 ... +50<br>~~a~~|–5 ... +50|
||–20 ... +70<br>~~a~~|–20 ... +70|
|Certification<br>~~a~~<br>~~|~~|–<br>~~a~~<br>~~|~~|c UL - Recognized (OL)<br>~~|~~|
|Materials<br>~~|~~<br>~~Re~~|Reinforced PA, PC<br>~~|~~<br>~~Re~~|PA-reinforced<br>~~|~~<br>~~Re~~|
|Note on materials<br>~~CO~~|–<br>~~CO~~|RoHS-compliant<br>~~CO~~|
|PWIS conformity<br>~~OO~~|VDMA24364-B2-L<br>~~OO~~|VDMA24364-B2-L<br>~~OO~~|
|Grid dimension<br>[mm]<br>~~OO~~|50<br>~~OO~~|50<br>~~OO~~|
|Dimensions (including interlinking block and connection block)<br>W x L x H<br>[mm]|50 x 107 x 50|50 x 107 x 41|
|Product weight<br>[g]<br>~~ee~~|48<br>~~ee~~|171<br>~~ee~~|
Subject to change – 2023/10
172
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input/output module, digital
## **Connection and display components**
**==> picture [523 x 123] intentionally omitted <==**
**----- Start of picture text -----**<br>
CPX-8DE-8DA CPX-L-8DE-8DA<br>1 2 [1] Status LEDs (green): for allocation 2 [1] Status LEDs (green) for each input<br>to the inputs a pin allocation of signal<br>3 the module [2] Error LED (red, module error)<br>8 01 45 01 45 8 [2] Status LEDs (yellow): for alloca-<br>DI 2 6 2 6 DO tion to the inputs a pin alloca-<br>3 7 3 7 tion of the module<br>[3] Error LED (red) (module error)<br>1 2<br>1 1<br>**----- End of picture text -----**<br>
**==> picture [523 x 312] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection block/digital I/O module combinations<br>Connection blocks Part no. Digital I/O module<br>CPX-8DE-8DA CPX-L-8DE-8DA<br>CPX-AB-4-M12-8POL 526178 h –<br>CPX-AB-8-KL-4POL 195708 h –<br>CPX-AB-1-SUB-BU-25POL 525676 h –<br>Pin allocation<br>Connection block inputs/outputs CPX-8DE-8DA<br>CPX-AB-4-M12-8POL<br>X1.1: 24 VSEN X3.1: 24 VSEN<br>X1.2: Input x X3.2: Input x+4<br>X1.3: Input x+1 X3.3: Input x+5<br>X1.4: 0 VSEN X3.4: 0 VSEN<br>X1.5: Output x X3.5: Output x+4<br>X1.6: Output x+1 X3.6: Output x+5<br>X1.7: Input x+4 X3.7: n.c.<br>X1.8: 0 VOUT X3.8: 0 VOUT<br>X2.1: 24 VSEN X4.1: 24 VSEN<br>X2.2: Input x+2 X4.2: Input x+6<br>X2.3: Input x+3 X4.3: Input x+7<br>X2.4: 0 VSEN X4.4: 0 VSEN<br>X2.5: Output x+2 X4.5: Output x+6<br>X2.6: Output x+3 X4.6: Output x+7<br>X2.7: Input x+6 X4.7: n.c.<br>X2.8: 0 VOUT X4.8: 0 VOUT<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
173
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input/output module, digital
## **Pin allocation**
**==> picture [524 x 397] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection block inputs/outputs CPX-8DE-8DA<br>CPX-AB-8-KL-4POL<br>X1.0: 24 VSEN X5.0: Output x+4<br>X1 .0 .0 X5<br>.1 .1 X1.1: 0 VSEN X5.1: 0 VOUT<br>.2.3 .2.3 X1.2: Input x X5.2: Output x<br>.0 .0 X1.3: FE X5.3: FE<br>X2 .1.2 .1.2 X6 X2.0: Input x+4 X6.0: Output x+5<br>.3.0 .3.0 X2.1: Input x+5 X6.1: 0 VOUT<br>X3 .1.2 .1.2 X7 X2.2: Input x+1 X6.2: Output x+1<br>.3 .3 X2.3: FE X6.3: FE<br>.0.1 .0.1 X3.0: 24 VSEN X7.0: Output x+6<br>X4 .2.3 .2.3 X8 X3.1: 0 VSEN X7.1: 0 VOUT<br>X3.2: Input x+2 X7.2: Output x+2<br>X3.3: FE X7.3: FE<br>X4.0: Input x+6 X8.0: Output x+7<br>X4.1: Input x+7 X8.1: 0 VOUT<br>X4.2: Input x+3 X8.2: Output x+3<br>X4.3: FE X8.3: FE<br>CPX-AB-1-SUB-BU-25POL<br>1: Input x 14: Output x<br>2: Input x+1 15: Output x+1<br>3: Input x+2 16: Output x+2<br>4: Input x+3 17: Output x+3<br>5: Input x+4 18: Output x+4<br>6: Input x+5 19: Output x+5<br>7: Input x+6 20: Output x+6<br>8: Input x+7 21: Output x+7<br>9: 24 VSEN 22: 0 VOUT<br>10: 24 VSEN 23: 0 VOUT<br>11: 0 VSEN 24: 0 VOUT<br>12: 0 VSEN 25: FE<br>13: FE Housing: FE<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
d **Internet: www.festo.com/catalogue/...**
174
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input/output module, digital
**==> picture [523 x 410] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pin allocation<br>Connection block inputs CPX-L-8DE-8DA<br>X1.0: 24 VSEN X9.0: 24 VSEN<br>X1.1: Input x X9.1: Output x<br>X1.2: 0 VSEN+out X9.2: 0 VSEN+out<br>X2.0: 24 VSEN X10.0: 24 VSEN<br>X2.1: Input x+1 X10.1: Output x+1<br>X2.2: 0 VSEN+out X10.2: 0 VSEN+out<br>X3.0: 24 VSEN X11.0: 24 VSEN<br>X3.1: Input x+2 X11.1: Output x+2<br>X3.2: 0 VSEN+out X11.2: 0 VSEN+out<br>X4.0: 24 VSEN X12.0: 24 VSEN<br>X4.1: Input x+3 X12.1: Output x+3<br>X4.2: 0 VSEN+out X12.2: 0 VSEN+out<br>X5.0: 24 VSEN X13.0: 24 VSEN<br>X5.1: Input x+4 X13.1: Output x+4<br>X5.2: 0 VSEN+out X13.2: 0 VSEN+out<br>X6.0: 24 VSEN X14.0: 24 VSEN<br>X6.1: Input x+5 X14.1: Output x+5<br>X6.2: 0 VSEN+out X14.2: 0 VSEN+out<br>X7.0: 24 VSEN X15.0: 24 VSEN<br>X7.1: Input x+6 X15.1: Output x+6<br>X7.2: 0 VSEN+out X15.2: 0 VSEN+out<br>X8.0: 24 VSEN X16.0: 24 VS7<br>X8.1: Input x+7 X16.1: Output x+7<br>X8.2: 0 VSEN+out X16.2: 0 VSEN+out<br>Interlinking block CPX-L-8DE-8DA<br>The module combines the 0 V potential of the power supply for elec- If all pins of the outputs of an output module connected to the right<br>tronics and sensors with the 0 V potential of the power supply for of the input/output module are to be switched off, an appropriate in-<br>outputs in the CPX interlinking module. terlinking block with additional supply for outputs must be used to<br>the right of the input/output module.<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
175
**==> picture [596 x 40] intentionally omitted <==**
## Terminal CPX
## Data sheet – Input/output module, digital
**==> picture [524 x 558] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>Input/output module, digital<br>8 digital inputs, 8 digital outputs 526257 CPX-8DE-8DA<br>8 digital inputs, 8 digital outputs, for CPX in plastic, including interlinking block and connection block 572607 CPX-L-8DE-8DA-16-KL-3POL<br>with spring-loaded terminals<br>Connection block<br>Plastic 4x socket M12, 8-pin 526178 CPX-AB-4-M12-8POL<br>Spring-loaded terminal, 32-pin 195708 CPX-AB-8-KL-4POL<br>1x socket, Sub-D, 25-pin 525676 CPX-AB-1-SUB-BU-25POL<br>Plug<br>Sub-D plug, 25-pin 527522 SD-SUB-D-ST25<br>Connecting cable<br>Connecting cable M12 525617 KM12-8GD8GS-2-PU<br>Cover<br>Cover for CPX-AB-8-KL-4POL (IP65, IP67) 538219 AK-8KL<br>• 8 cable through feeds M9<br>• 1 cable through feed for multi-pin plug<br>Fittings kit 538220 VG-K-M9<br>Screening plate<br>Screening plate for M12 connections 526184 CPX-AB-S-4-M12<br>User documentation<br>User documentation German 526439 P.BE-CPX-EA-DE<br>English 526440 P.BE-CPX-EA-EN<br>Spanish 526441 P.BE-CPX-EA-ES<br>French 526442 P.BE-CPX-EA-FR<br>Italian 526443 P.BE-CPX-EA-IT<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
176
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Counter module, digital
## **Function**
## **Area of application**
The counter module has two channels. • Continuous counting Depending on the parameterisation, • One-off counting to count limit these can independently be used as • One-off counting to count limit, counter inputs or as incremental value return to load value encoder inputs or SSI. The counter • Periodic counting module additionally has one output • Measurement of frequencies per channel. The outputs can either be • Measurement of rotational speeds controlled by a counter channel or an • Measurement of duty cycle incremental value encoder channel, • Measurement of position i.e. through an event such as "Compar• Measurement of speed ative value reached". Alternatively, out• Measuring with pulse generators puts can also be controlled via process • Measurement with pulse generators data. and direction encoders
- Measurement with incremental encoders
- Measurement with SSI absolute encoders
## **Description**
Applications
- Recording travel and speed of a con• Systems for filling by weight and volveyor ume
- • Position and speed synchronisation • Monitoring motor speeds of conveyors and pick & place appli• Measuring equipment for determincations ing the position of axis systems (lin-
- • Counting goods e.g. in packaging inear, rotational) stallations
- Controlling fast-switching valves
- Controlling the opening time of a valve
- Activating semiconductor relays
- Temperature monitoring and rotational speed control for drives
- Change of direction in fast drives
- Control of motors with pulse-width modulation (PWM)
## Supported devices
- 5 V incremental encoder, sin• 24 V incremental encoder, sin• 24 V pulse generator with or without • Absolute encoder with SSI interface gle-ended or differential, with two gle-ended, with two 90° phase offdirection level (13 bits to 25 bits) 90° phase offset tracks set tracks • 24 V direct current motors
2023/10 – Subject to change
d **Internet: www.festo.com/catalogue/...**
177
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Counter module, digital
## **General technical data**
**==> picture [524 x 579] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type CPX-2ZE2DA<br>Number Inputs 2<br>Outputs 2<br>Max. power supply Inputs [A] 2<br>Per module Outputs [A] 10<br>Max. power supply per channel [A] 5 (adjustable, 20 W lamp load)<br>Max. cable length [m] 30<br>Fuse protection (short circuit) Internal electronic fuse per channel<br>Intrinsic current consumption at nominal operating voltage [mA] Typically 35<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Galvanic isolation, inputs Channel – channel No<br>Channel – internal bus No<br>Galvanic isolation, outputs Channel – channel No<br>Channel – internal bus Yes, with intermediate supply<br>Characteristic curve Inputs To IEC 1131-2, type 02<br>Outputs IEC 1131-T2<br>Switching level Signal 0 [V DC] š 5<br>Signal 1 [V DC] › 11<br>Input debounce time [μs] 0.1 (0.2 μs, 0.4 μs, 0.8 μs, 1 μs, 2 μs, 4 μs, 8 μs, 10 μs, 50 μs, 100 μs, 500 μs, 1 ms,<br>3 ms, 10 ms, 20 ms parameterisable)<br>Switching logic Inputs Positive logic (PNP)<br>Outputs • Negative logic (NPN)<br>• Positive logic (PNP)<br>• Push-pull driver<br>LED displays Group diagnostics 1<br>Channel diagnostics 2<br>Channel status 10<br>Module diagnostics 2<br>Diagnostics Operating mode-dependent diagnostics<br>Parameterisation • Switch-on/off delay<br>• Frequency output<br>• Speed measurement<br>• Impulse output<br>• Pulse train<br>• Rotational speed measurement<br>• Frequency measurement<br>• Period duration measurement<br>• Motor operating mode<br>• Determine position<br>• Pulse width modulation<br>• One-off counting<br>• Continuous counting<br>• Periodic counting<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Certification UL – Recognized (OL)<br>Information on materials: Housing Plastic<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block and connection block) [mm] 50 x 107 x 50<br>W x L x H<br>Product weight [g] 130<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
178
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Counter module, digital
## **Connection and display components**
## CPX-2ZE2DA
**==> picture [95 x 90] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2<br>3<br>1 2<br>**----- End of picture text -----**<br>
- [1] Status LEDs (green): for allocation to the inputs a pin allocation of the module
- [2] Status LEDs (yellow, red): for allocation to the inputs a pin allocation of the module
- [3] Error LED (red) (module error)
## **Pin allocation**
**==> picture [523 x 226] intentionally omitted <==**
**----- Start of picture text -----**<br>
Inputs/outputs CPX-2ZE2DA<br>Channel 0 Channel 1<br>X1 .0.1 .0.1 X5 X1.0: Input X5.0: Input<br>.2 .2 X1.1: Input X5.1: Input<br>.3 .3<br>.0 .0 X1.2: Input X5.2: Input<br>X2 .1 .1 X6 X1.3: Input X5.3: Input<br>.2 .2<br>.3 .3 X2.0: Input X6.0: Input<br>.0 .0<br>.1 .1 X2.1: Input X6.1: Input<br>X3 .2 .2 X7 X2.2: 5 V DC X6.2: 5 V DC<br>.3 .3<br>.0 .0 X2.3: 0 V X6.3: 0 V<br>.1 .1<br>.2 .2 X3.0: 24 V DC X7.0: 24 V DC<br>X4 .3 .3 X8<br>X3.1: 0 V X7.1: 0 V<br>X3.2: 24 V DC for digital input DI X7.2: 24 V DC for digital input DI<br>X3.3: Digital input DI X7.3: Digital input DI<br>X4.0: 0 V for digital input DI X8.0: 0 V for digital input DI<br>X4.1: Digital output DO X8.1: Digital output DO<br>X4.2: Reference potential for DO X8.2: Reference potential for DO<br>X4.3: FE X8.3: FE<br>**----- End of picture text -----**<br>
## - **Note** H-
The allocation and designation of inputs differs fundamentally depending on which type of encoder is connected. Appropriate allocation diagrams can be found in the user documentation for the counter module.
2023/10 – Subject to change
179
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Counter module, digital
## **Ordering data**
**==> picture [524 x 228] intentionally omitted <==**
**----- Start of picture text -----**<br>
Designation Part no. Type<br>Counter module, digital<br>2 digital inputs, 2 digital outputs 576046 CPX-2ZE2DA<br>Cover<br>Cover for CPX-2ZE2DA (IP65, IP67) 538219 AK-8KL<br>• 8 cable through feeds M9<br>• 1 cable through feed for multi-pin plug<br>Fittings kit 538220 VG-K-M9<br>User documentation<br>User documentation for counter module CPX-2ZE2DA German 8035733 P.BE-CPX-2ZE2DA-DE<br>English 8035734 P.BE-CPX-2ZE2DA-EN<br>Spanish 8035735 P.BE-CPX-2ZE2DA-ES<br>French 8035736 P.BE-CPX-2ZE2DA-FR<br>Italian 8035737 P.BE-CPX-2ZE2DA-IT<br>Chinese 8035738 P.BE-CPX-2ZE2DA-ZH<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
180
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – HART input/output module
## **Function**
The HART input/output module allows the connection of up to 4 sensors or actuators. The corresponding communication channel is made available for sensors or actuators that communicate using the HART protocol. With the HART protocol, a conventional analogue 4 ... 20 mA current signal is modulated by a second frequency-modulated signal.
## **Area of application**
- Multi I/O module for 24 V DC supply voltage
- Supports connection blocks with M12 and terminal connection
- Module features can be parameterised
- The module receives the voltage supply for the electronics, outputs and the sensors from the interlinking block
Each of the 4 connections of the mod• Module protection and diagnostics ule can be configured as inputs or outthrough integrated electronic proputs. tection
## **General technical data**
Type CPX-4AE-4AA-H ~~a~~ Protocol HART ~~a~~ Number of selectable analogue inputs/outputs 4 Type of sensor 0 ... 20 mA 4 ... 20 mA 4 ... 20 mA with HART Operating voltage Nominal value [V DC] 24 ~~————————————————————~~ Permissible range [V DC] 18 ... 30 ~~a~~ Power failure buffering [ms] 10 ~~a~~ Intrinsic current consumption at nominal operating voltage [mA] Typically 170 ~~a~~ Maximum short circuit current [mA] 22 ~~a~~ Maximum open circuit voltage [V] 28.8 ~~a~~ Minimum available sensor voltage 20.7 V DC at 20 mA ~~I~~ Fuse protection (short circuit) Internal electronic fuse per channel ~~a~~ Reverse polarity protection For all electrical connections Galvanic isolation Channel – channel No Channel – internal bus Yes ~~—a~~ Signal range 0 ... 20 mA 4 ... 20 mA 4 ... 20 mA with HART Data format 15 bits + prefix ~~a~~ Scalable to 15 bits ~~a~~ Maximum load [Ω] 750 ~~————— a~~ Maximum input resistance [Ω] 300 ~~a~~ Maximum cable length [m] 500 ~~a~~ Basic error limit at 25°C [%] ±0.1 ~~a~~ Operating error limit related to the ambient temperature range [%] ±0.3 ~~a~~ Repetition accuracy 0.05% at 20°C LED displays Group diagnostics 1 Channel diagnostics 4 ~~a~~ Channel status ~~pT~~ 4 ~~a~~ Control elements DIL switch Diagnostics • Wire break per channel • Limit value violation per channel • Short circuit/overload per channel • Parameterisation error • Overflow/underflow • Limit value violation to NE43 per channel
2023/10 – Subject to change
181
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – HART input/output module
**==> picture [524 x 441] intentionally omitted <==**
**----- Start of picture text -----**<br>
General technical data<br>Parameterisation • Data format<br>• Failsafe per channel<br>• Forcing per channel<br>• Limit value monitoring per channel<br>• Idle mode per channel<br>• Measured value smoothing<br>• Signal range per channel<br>• Monitoring overflow/underflow<br>• Monitoring to NE43, inputs<br>• Monitoring of wire break per channel<br>• Wire break per channel<br>• Limit value violation per channel<br>• Short circuit/overload per channel<br>• Parameterisation error<br>• Overflow/underflow<br>• Limit value violation to NE43 per channel<br>• Number of HART repetitions<br>• Hysteresis for limit values<br>• HART variables (4 pieces)<br>• Behaviour after short circuit/overload<br>Degree of protection to EN 60529 Depending on connection block<br>Technical data – Mechanical components<br>Type of mounting On interlinking block<br>Product weight [g] 77.4<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block and connection block) [mm] 50 x 107 x 70<br>W x L x H<br>Materials<br>Housing Reinforced PA, PC<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Operating and environmental conditions<br>Ambient temperature [°C] –5 ... +50<br>Storage temperature [°C] –20 ... +70<br>Relative humidity [%] 95, non-condensing<br>Corrosion resistance class CRC [1)] 1 (when installed)<br>CE marking (see declaration of conformity) [3)] To EU EMC Directive [2)]<br>**----- End of picture text -----**<br>
- 1) Additional information: www.festo.com/x/topic/kbk
2) For information about the area of use, see the EC declaration of conformity at: www.festo.com/catalogue/... d Support/Downloads.
If the devices are subject to usage restrictions in residential, commercial or light-industrial environments, further measures for the reduction of the emitted interference may be necessary.
- 3) Additional information: www.festo.com/catalogue/... d Support/Downloads.
|**Safety characteristics**<br>Shock resistance<br>Shock test with severitylevel 2 to FN 942017-5 and EN 60068-2-27|**Safety characteristics**<br>Shock resistance<br>Shock test with severitylevel 2 to FN 942017-5 and EN 60068-2-27|
|---|---|
|Vibration resistance|Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6|
Subject to change – 2023/10
182
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – HART input/output module
## **Connection and display components**
## CPX-4EA-4AA-H
~~1 2~~ [1] Status LEDs: [3] Error LED (red) – Inputs (green) (module error) 3 – Outputs (yellow) a Pin allocation for module [2] Error LEDs (red): for allocation to the inputs a pin allocation of the module
~~1~~
## **Combinations of bus nodes/control blocks with HART input/output module**
**==> picture [523 x 290] intentionally omitted <==**
**----- Start of picture text -----**<br>
Bus node/control block Part no. Protocol Can be combined as of HART variables in process Full HART functionality<br>release image only<br>CPX-CEC-C1-V3 3473128 CODESYS Level 2 3.5.12.174 – h<br>CPX-CEC-M1-V3 3472765 CODESYS Level 2 3.5.12.174 – h<br>CPX-CEC-S1-V3 3472425 CODESYS Level 2 3.5.12.174 – h<br>CPX-FB11 526172 DeviceNet 25 h –<br>CPX-FB13 195740 PROFIBUS 34 – h<br>CPX-FB14 526174 CANopen 30 h –<br>CPX-FB36 1912451 EtherNet/IP 15 – h<br>CPX-FB37 2735960 EtherCAT 7 h –<br>CPX-FB43 8110369 PROFINET RT, M12 45 – h<br>CPX-M-FB44 8110370 PROFINET RT, RJ45 45 – h<br>CPX-M-FB45 8110371 PROFINET RT, SCRJ 45 – h<br>Combinations of connection blocks with HART input/output module<br>Connection blocks Part no. HART input/output module<br>CPX-4EA-4AA-H<br>CPX-P-AB-4XM12-4POL 565706 h<br>CPX-P-AB-2XKL-8POL 565704 h<br>Combinations of connection blocks with interlinking block<br>Connection blocks Part no. Plastic interlinking block Metal interlinking block<br>CPX-GE... CPX-M-GE...<br>CPX-P-AB-4XM12-4POL 565706 – h<br>CPX-P-AB-2XKL-8POL 565704 h h<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
183
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – HART input/output module
## **Pin allocation**
**==> picture [524 x 283] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection block inputs/outputs CPX-4AE-4AA-H<br>Inputs Outputs<br>CPX-P-AB-4XM12-4POL<br>X1.1: 24 VSEN x X3.1: 24 VSEN x+2 X1.1: Output I0+ X3.1: Output I2+<br>X1.2: 0 V X3.2: 0 V X1.2: 0 V X3.2: 0 V<br>X1.3: Input x X3.3: Input x+2 X1.3: – X3.3: –<br>X1.4: 0 V X3.4: 0 V X1.4: 0 V X3.4: 0 V<br>X2.1: 24 VSEN x+1 X4.1: 24 VSEN x+3 X2.1: Output I1+ X4.1: Output I3+<br>X2.2: 0 V X4.2: 0 V X2.2: 0 V X4.2: 0 V<br>X2.3: Input x+1 X4.3: Input x+3 X2.3: – X4.3: –<br>X2.4: 0 V X4.4: 0 V X2.4: 0 V X4.4: 0 V<br>CPX-P-AB-2XKL-8POL<br>X1.1: 24 VSEN x X2.1: 24 VSEN x+2 X1.1: Output I0+ X2.1: Output I2+<br>X1.2: 0 V X2.2: 0 V X1.2: 0 V X2.2: 0 V<br>X1.3: Input x X2.3: Input x+2 X1.3: – X2.3: –<br>X1.4: 0 V X2.4: 0 V X1.4: 0 V X2.4: 0 V<br>X1.5: 24 VSEN x+1 X2.5: 24 VSEN x+3 X1.5: Output I1+ X2.5: Output I3+<br>X1.6: 0 V X2.6: 0 V X1.6: 0 V X2.6: 0 V<br>X1.7: Input x+1 X2.7: Input x+3 X1.7: – X2.7: –<br>X1.8: 0 V X2.8: 0 V X1.8: 0 V X2.8: 0 V<br>**----- End of picture text -----**<br>
## - **Note** H-
In the case of mixed operation of inputs and outputs in one module, the connections are first assigned input signals and then output signals, in ascending order.
Subject to change – 2023/10
184
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – HART input/output module
**==> picture [523 x 388] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>HART input/output module<br>4 analogue inputs/outputs 8059847 CPX-4AE-4AA-H<br>Connection block<br>Plastic 4x socket, M12, 4-pin 565706 CPX-P-AB-4XM12-4POL<br>2x plug, 8-pin 565704 CPX-P-AB-2XKL-8POL<br>Plug<br>8-pin socket Spring-loaded ter- Connection cross section 0.2 ... 2.5 mm [2] 565712 NECU-L3G8-C1<br>minal<br>Screw terminal Connection cross section 0.2 ... 2.5 mm [2] 565710 NECU-L3G8-C2<br>Plug M12x1, 4-pin, straight, Screw terminal Connection cross section 0.14 ... 0.5 mm [2] 192008 SEA-4GS-7-2.5<br>A-coded Nominal conductor cross section 18666 SEA-GS-7<br>14 ... 0.75 mm [2]<br>Permissible cable @ 4 ... 6 mm<br>Connection cross section 0.75 mm [2] 18778 SEA-GS-9<br>Permissible cable @ 6 ... 8 mm<br>Cover<br>Cover cap for sealing unused connections M12x1 (10 pieces) 165592 ISK-M12<br>Coding element<br>To ensure that a coded socket NECU-L3G8 can only be inserted in the matching For NECU-L3G8 565713 CPX-P-KDS-AB-2XKL<br>coded connection block CPX-P-AB-2XKL (96 of each)<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
185
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Input module, analogue
## **Function**
Analogue modules control devices with a standardised analogue interface such as pressure switches, temperature, flow rate, filling level, etc. Depending on the connection block selected, the analogue module supports various connection concepts with different numbers of sockets or terminals.
## **Area of application**
- Analogue module for 0 ... 10 V, 0 ... 20 mA or 4 ... 20 mA
- Supports connection blocks with Sub-D, terminal connection and M12 connection
- Analogue module features can be parameterised
- Different data formats available
- Operation with and without galvanic isolation possible
- The analogue module receives the voltage supply for the electronics and the sensors from the interlinking block
- Analogue module protection and diagnostics through integrated electronic fuse protection
## **General technical data**
Type CPX-2AE-U-I CPX-4AE-U-I CPX-4AE-I ~~es~~ Voltage input ~~es~~ Current input Voltage input Current input ~~ee~~ Current input ~~a~~ Number of analogue inputs 2 4 4 ~~a~~ Max. power supply per module [A] 0.7 ~~a~~ Fuse protection Internal electronic fuse ~~a~~ Current consumption from 24 V sensor supply (quiescent current) [mA] Typically 50 ~~a~~ Current consumption from 24 V sensor supply (at full load) [A] Max. 0.7 ~~a~~ Nominal operating voltage for load voltage [V DC] 24 ±2% ~~a~~ Nominal operating voltage [V DC] 24 ~~a~~ Operating voltage range [V DC] 18 ... 30 Signal range (parameterisable for each channel with 0 ... 10 V 0 ... 20 mA 1 ... 5 V 0 ... 20 mA 0 ... 20 mA DIL switch or software) 4 ... 20 mA 0 ... 10 V 4 ... 20 mA 4 ... 20 mA –5 ... +5 V –20 ... +20 mA –10 ... +10 V ~~a~~ Operational error limit [%] ±0.5 – ±0.3 ±0.3 ±0.6 ~~a~~ Basic error limit (at 25°C) [%] ±0.3 – ±0.2 ±0.2 ±0.5 ~~a~~ Repetition accuracy (at 25°C) [%] 0.15 0.15 0.1 0.1 0.15 ~~GO~~ Input resistance 100 kΩ š 100 Ω 100 kΩ š 100 Ω š 100 Ω ~~a~~ Max. permissible input voltage [V DC] 30 – –30 ... +30 – – Max. permissible input current [mA] – 40 – Internally limited 40 ~~es~~ to 60 ~~a~~ Conversion time per channel [ μs] Typically 150 ~~a~~ Cycle time (module) [ms] š 4 š 0.5 š 10 Data format 12 bits + prefix 15 bits + prefix 12 bits + prefix Scalable to 15 bits Scalable to 15 bits Scalable to ~~a~~ 15 bits ~~a~~ Cable length [m] ~~e~~ Max. 30 (shielded) ~~e~~ ~~**e** ee~~
Subject to change – 2023/10
186
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, analogue
## **General technical data**
**==> picture [523 x 343] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type CPX-2AE-U-I CPX-4AE-U-I CPX-4AE-I<br>Galvanic isolation Channel – channel No<br>Channel – internal bus Yes, with external sensor supply<br>LED displays Group diagnostics 1<br>Channel diagnostics Via flashing frequency of 4 Via flashing frequency of<br>group diagnostics group diagnostics<br>Diagnostics Wire break per channel<br>Limit value violation per channel<br>Parameterisation error<br>Short circuit, input signal Overload at input Short circuit, input signal<br>– –<br>Overflow/underflow<br>– –<br>Short circuit in sensor sup-<br>ply<br>Parameterisation Data format<br>Forcing per channel<br>Limit value monitoring per channel<br>Measured value smoothing<br>Signal range per channel<br>Monitoring of wire break per channel<br>Behaviour after short circuit<br>– Behaviour after overload at –<br>input<br>– Sensor supply active –<br>Degree of protection to EN 60529 Depending on connection block<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Materials Reinforced PA, PC<br>Note on materials – RoHS-compliant –<br>PWIS conformity VDMA24364-B2-L VDMA24364-B2-L VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block and connection block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 48 46 47<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
187
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, analogue
**==> picture [522 x 100] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection and display components<br>CPX-2AE-U-I and CPX-4AE-I CPX-4AE-U-I<br>[1] Error LED (red; module error) [1] Error LED (red; module error)<br>1 1<br>[2] Channel-related error LEDs (red)<br>2<br>AI<br>2<br>**----- End of picture text -----**<br>
**==> picture [524 x 482] intentionally omitted <==**
**----- Start of picture text -----**<br>
Combinations of connection blocks and analogue module<br>Connection blocks Part no. Analogue module<br>CPX-2AE-U-I CPX-4AE-U-I CPX-4AE-I<br>CPX-AB-4-M12X2-5POL 195704 h h h<br>CPX-AB-4-M12X2-5POL-R 541254 h h h<br>CPX-AB-8-KL-4POL 195708 h h h<br>CPX-AB-1-SUB-BU-25POL 525676 h h h<br>CPX-M-AB-4-M12X2-5POL 549367 h h h<br>Pin allocation<br>Connection block inputs CPX-2AE-U-I CPX-4AE-U-I CPX-4AE-I<br>CPX-AB-4-M12X2-5POL, CPX-AB-4-M12X2-5POL-R [1)] and CPX-M-AB-4-M12X2-5POL<br>X1.1: 24 VSEN X3.1: 24 VSEN X1.1: 24 VSEN X3.1: 24 VSEN X1.1: 24 VSEN X3.1: 24 VSEN<br>X1.2: Input U0+ X3.2: Input U1+ X1.2: Input 0+ X3.2: Input 2+ X1.2: Input I0+ X3.2: Input I2+<br>X1.3: 0 VSEN X3.3: 0 VSEN X1.3: 0 VSEN X3.3: 0 VSEN X1.3: 0 VSEN X3.3: 0 VSEN<br>X1.4: Input U0– X3.4: Input U1– X1.4: Input 0– X3.4: Input 2– X1.4: Input I0– X3.4: Input I2–<br>X1.5: FE [2)] X3.5: FE [2)] X1.5: FE [2)] X3.5: FE [2)] X1.5: FE [2)] X3.5: FE [2)]<br>X2.1: 24 VSEN X4.1: 24 VSEN X2.1: 24 VSEN X4.1: 24 VSEN X2.1: 24 VSEN X4.1: 24 VSEN<br>X2.2: Input I0+ X4.2: Input I1+ X2.2: Input 1+ X4.2: Input 3+ X2.2: Input I1+ X4.2: Input I3+<br>X2.3: 0 VSEN X4.3: 0 VSEN X2.3: 0 VSEN X4.3: 0 VSEN X2.3: 0 VSEN X4.3: 0 VSEN<br>X2.4: Input I0– X4.4: Input I1– X2.4: Input 1– X4.4: Input 3– X2.4: Input I1– X4.4: Input I3–<br>X2.5: FE [2)] X4.5: FE [2)] X2.5: FE [2)] X4.5: FE [2)] X2.5: FE [2)] X4.5: FE [2)]<br>CPX-AB-8-KL-4POL<br>X1.0: 24 VSEN X5.0: 24 VSEN X1.0: 24 VSEN X5.0: 24 VSEN X1.0: 24 VSEN X5.0: 24 VSEN<br>X1 .0 .0 X5<br>.1 .1 X1.1: 0 VSEN X5.1: 0 VSEN X1.1: 0 VSEN X5.1: 0 VSEN X1.1: 0 VSEN X5.1: 0 VSEN<br>.2.3 .2.3 X1.2: Input U0– X5.2: Input U1– X1.2: Input 0– X5.2: Input 2– X1.2: Input I0– X5.2: Input I2–<br>.0 .0 X1.3: FE X5.3: FE X1.3: FE X5.3: FE X1.3: FE X5.3: FE<br>X2 .1.2 .1.2 X6 X2.0: n.c. X6.0: n.c. X2.0: n.c. X6.0: n.c. X2.0: n.c. X6.0: n.c.<br>.3 .3 X2.1: n.c. X6.1: n.c. X2.1: n.c. X6.1: n.c. X2.1: n.c. X6.1: n.c.<br>.0 .0<br>X3 .1.2 .1.2 X7 X2.2: Input U0+ X6.2: Input U1+ X2.2: Input 0+ X6.2: Input 2+ X2.2: Input I0+ X6.2: Input I2+<br>.3 .3 X2.3: FE X6.3: FE X2.3: FE X6.3: FE X2.3: FE X6.3: FE<br>.0.1 .0.1 X3.0: 24 VSEN X7.0: 24 VSEN X3.0: 24 VSEN X7.0: 24 VSEN X3.0: 24 VSEN X7.0: 24 VSEN<br>X4 .2.3 .2.3 X8 X3.1: 0 VSEN X7.1: 0 VSEN X3.1: 0 VSEN X7.1: 0 VSEN X3.1: 0 VSEN X7.1: 0 VSEN<br>X3.2: Input I0– X7.2: Input I1– X3.2: Input 1– X7.2: Input 3– X3.2: Input I1– X7.2: Input I3–<br>X3.3: FE X7.3: FE X3.3: FE X7.3: FE X3.3: FE X7.3: FE<br>X4.0: n.c. X8.0: n.c. X4.0: n.c. X8.0: n.c. X4.0: n.c. X8.0: n.c.<br>X4.1: n.c. X8.1: n.c. X4.1: n.c. X8.1: n.c. X4.1: n.c. X8.1: n.c.<br>X4.2: Input I0+ X8.2: Input I1+ X4.2: Input 1+ X8.2: Input 3+ X4.2: Input I1+ X8.2: Input I3+<br>X4.3: FE X8.3: FE X4.3: FE X8.3: FE X4.3: FE X8.3: FE<br>**----- End of picture text -----**<br>
- 1) Speedcon quick lock, additional shielding on metal thread
- 2) FE/shield additionally on metal thread
Subject to change – 2023/10
188
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, analogue
## **Pin allocation**
**==> picture [523 x 184] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection block inputs CPX-2AE-U-I CPX-4AE-U-I CPX-4AE-I<br>CPX-AB-1-SUB-BU-25POL<br>1: Input U0– 14: Input U1– 1: Input 0– 14: Input 2– 1: Input I0– 14: Input I2–<br>2: Input U0+ 15: Input U1+ 2: Input 0+ 15: Input 2+ 2: Input I0+ 15: Input I2+<br>3: Input I0– 16: Input I1– 3: Input 1– 16: Input 3– 3: Input I1– 16: Input I3–<br>4: Input I1+ 17: Input I1+ 4: Input 1+ 17: Input 3+ 4: Input I1+ 17: Input I3+<br>5: n.c. 18: 24 VSEN 5: n.c. 18: 24 VSEN 5: n.c. 18: 24 VSEN<br>6: n.c. 19: n.c. 6: n.c. 19: n.c. 6: n.c. 19: n.c.<br>7: n.c. 20: 24 VSEN 7: n.c. 20: 24 VSEN 7: n.c. 20: 24 VSEN<br>8: n.c. 21: n.c. 8: n.c. 21: n.c. 8: n.c. 21: n.c.<br>9: 24 VSEN 22: 0 VSEN 9: 24 VSEN 22: 0 VSEN 9: 24 VSEN 22: 0 VSEN<br>10: 24 VSEN 23: 0 VSEN 10: 24 VSEN 23: 0 VSEN 10: 24 VSEN 23: 0 VSEN<br>11: 0 VSEN 24: 0 VSEN 11: 0 VSEN 24: 0 VSEN 11: 0 VSEN 24: 0 VSEN<br>12: 0 VSEN 25: FE 12: 0 VSEN 25: FE 12: 0 VSEN 25: FE<br>13: Shielding [1)] Housing: FE 13: Shielding [1)] Housing: FE 13: Shielding [1)] Housing: FE<br>**----- End of picture text -----**<br>
1) Connect shield to functional earth FE
2023/10 – Subject to change
189
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, analogue
## **Ordering data**
**==> picture [524 x 461] intentionally omitted <==**
**----- Start of picture text -----**<br>
Part no. Type<br>Input module, analogue<br>2 analogue current or voltage inputs 526168 CPX-2AE-U-I<br>4 analogue current or voltage inputs 573710 CPX-4AE-U-I<br>4 analogue current inputs 541484 CPX-4AE-I<br>Connection block<br>Plastic 4x socket M12, 5-pin 195704 CPX-AB-4-M12X2-5POL<br>4x socket, M12 with quick-lock technology, 5-pin 541254 CPX-AB-4-M12X2-5POL-R<br>Spring-loaded terminal, 32-pin 195708 CPX-AB-8-KL-4POL<br>1x socket, Sub-D, 25-pin 525676 CPX-AB-1-SUB-BU-25POL<br>Metal 4x socket M12, 5-pin 549367 CPX-M-AB-4-M12X2-5POL<br>Plug<br>Plug M12, 5-pin 175487 SEA-M12-5GS-PG7<br>Sub-D plug, 25-pin 527522 SD-SUB-D-ST25<br>Cover<br>Cover for CPX-AB-8-KL-4POL (IP65, IP67) 538219 AK-8KL<br>• 8 cable through feeds M9<br>• 1 cable through feed for multi-pin plug<br>Fittings kit 538220 VG-K-M9<br>Screening plate<br>Screening plate for M12 connections 526184 CPX-AB-S-4-M12<br>User documentation<br>User documentation German 526415 P.BE-CPX-AX-DE<br>English 526416 P.BE-CPX-AX-EN<br>Spanish 526417 P.BE-CPX-AX-ES<br>French 526418 P.BE-CPX-AX-FR<br>Italian 526419 P.BE-CPX-AX-IT<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
190
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Input module, analogue, with pressure sensors
## **Function**
The pressure input modules make it possible to process a maximum of 4 pressures. The internal measured value of the sensor (analogue value with 10-bit resolution) is converted into an internal numerical format as appropriate to the parameterisation and made available to the bus node as a process image. It is additionally also possible to combine 2 channels in each case to form a differential pressure channel.
## **Area of application**
- Measuring range: 0 ... 10 bar or –1 ... +1 bar
- Choice of units of measurement
- Processing a maximum of 4 pressures per module
- Pressure indication via LCD display
- Direct connection via QS4 push-in connectors
- Error message via CPX
- Channel-oriented diagnostics
## **General technical data**
|ate to the parameterisation and made<br>available to the bus node as a process<br>image. It is additionally also possible<br>to combine 2 channels in each case to<br>form a differential pressure channel.<br>• Direct connection via QS4 push-in<br>connectors<br>• Error message via CPX<br>• Channel-oriented diagnostics|ate to the parameterisation and made<br>available to the bus node as a process<br>image. It is additionally also possible<br>to combine 2 channels in each case to<br>form a differential pressure channel.<br>• Direct connection via QS4 push-in<br>connectors<br>• Error message via CPX<br>• Channel-oriented diagnostics|ate to the parameterisation and made<br>available to the bus node as a process<br>image. It is additionally also possible<br>to combine 2 channels in each case to<br>form a differential pressure channel.<br>• Direct connection via QS4 push-in<br>connectors<br>• Error message via CPX<br>• Channel-oriented diagnostics|
|---|---|---|
|**General technical data**<br>Type<br>CPX-4AE-P-B2<br>CPX-4AE-P-D10<br>Number of analogue inputs<br>4|||
|Pneumatic connection|QS-4||
|Nominal operatingvoltage<br>[V DC]|24||
|Operatingvoltage range<br>[V DC]|18 ... 30||
|Intrinsic current consumption<br>[mA]|Typically50||
|Measured variable|4 x relative or 2 x differentialpressure measurement||
|Displayable units|• kPa<br>• mbar<br>•psi||
|Pressure measuring range<br>Start value<br>[bar]<br>Final value<br>[bar]|–1|0|
||1|10|
|Internal cycle time<br>[ms]|5||
|Data format|• 15 bits + prefix<br>• Binarynotation in mbar, kPa,psi||
|LED displays|Groupdiagnostics||
|Diagnostics|• Limit value violation per channel<br>• Parameterisation error<br>• Sensor limitper channel||
|Parameterisation|• Diagnostic delay per channel<br>• Hysteresis per module<br>• Unit of measurement<br>• Measured value smoothing per channel<br>• Limit value monitoring per channel<br>• Sensor limit per channel<br>• Measurement of relative/differentialpressure||
|Degree ofprotection to EN 60529|IP65, IP67||
|Operatingmedium|Compressed air to ISO 8573-1:2010 [7:4:4]||
|Note on the operating/pilot medium|Lubricated operationpossible (in which case lubricated operation will always be required)||
|Ambient temperature<br>[°C]|–5 ... 50||
|Storage temperature<br>[°C]|–20 ... 70||
|Temperature of medium<br>[°C]|0 ... 50||
|Note on materials|RoHS-compliant||
|Materials|Reinforced PA, PC||
|PWIS conformity|VDMA24364-B2-L||
|Grid dimension<br>[mm]|50||
|Dimensions (includinginterlinkingblock) W x L x H<br>[mm]|50 x 107 x 55||
|Product weight<br>[g]|115||
## - **Note** H-
Extreme pneumatic conditions, e.g. high cycle rate with high pressure amplitudes, can damage the sensors.
2023/10 – Subject to change
191
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
Data sheet – Input module, analogue, with pressure sensors
## **Connection and display components**
**==> picture [524 x 388] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 [1] Error LED (red; module error)<br>[2] LCD display with permanent dis-<br>2 play of the four measured pres-<br>sures, unit of measurement and if<br>3<br>applicable limit value violation<br>[3] QS connections<br>3<br>3<br>3<br>Ordering data<br>Designation Part no. Type<br>Input module, analogue<br>4 analogue pressure inputs, pressure range –1 ... +1 bar 560361 CPX-4AE-P-B2<br>4 analogue pressure inputs, pressure range 0 ... 10 bar 560362 CPX-4AE-P-D10<br>Inscription labels<br>Inscription labels 6x10 mm, 64 pieces, in frame 18576 IBS-6x10<br>User documentation<br>User documentation German 526415 P.BE-CPX-AX-DE<br>English 526416 P.BE-CPX-AX-EN<br>Spanish 526417 P.BE-CPX-AX-ES<br>French 526418 P.BE-CPX-AX-FR<br>Italian 526419 P.BE-CPX-AX-IT<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
192
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Input module, analogue, for temperature inputs
## **Area of application**
## **Function**
The CPX-PT100 analogue input module • Temperature module for temperawith 4 channels for temperature measture sensors PT100, PT200, PT500, urement enables the connection of up PT1000, Ni100, Ni120, Ni500, to 4 temperature sensors of the type Ni1000 PT100-PT1000, Ni100-Ni1000, etc. • Supports connection blocks with The temperature module supports varM12 and terminal connection ious connection concepts with different • Temperature module features can numbers of sockets or terminals as apbe parameterised propriate to the connection block se• 2-wire, 3-wire and 4-wire conneclected. tion
- Temperature module for temperature sensors PT100, PT200, PT500, PT1000, Ni100, Ni120, Ni500, Ni1000
- The temperature module is provided with voltage supply for the electronics and the sensors via the interlinking block
- Temperature module protection and diagnostics through integrated electronic fuse protection
## **General technical data**
|ics and the sensors via the interlink-<br>ing block<br>• Temperature module protection and<br>diagnostics through integrated elec-<br>tronic fuse protection|ics and the sensors via the interlink-<br>ing block<br>• Temperature module protection and<br>diagnostics through integrated elec-<br>tronic fuse protection|
|---|---|
|**General technical data**<br>Type<br>CPX-4AE-T<br>Temperature input<br>Number of analogue inputs<br>Choice of 2 or 4||
||Temperature input<br>Choice of 2 or 4|
|Max.power supply per module<br>[A]|0.7|
|Fuseprotection|Internal electronic fuse for sensor supply|
|Current consumption from 24 V sensor supply(quiescent current)<br>[mA]|Typically50|
|Sensor supplyvoltage<br>[V DC]|24 ±25%|
|Sensor type (parameterisable for each channel with DIL switch)|PT100, PT200, PT500, PT1000<br>Ni100, Ni120, Ni500, Ni1000|
|Temperature range<br>Pt standard<br>[°C]<br>Pt climatic<br>[°C]<br>Ni<br>[°C]|–200 ... +850|
||–120 ... +130|
||–60 ... +180|
|Sensor connection technology|2-wire, 3-wire and 4-wire technology|
|Resolution|15 bits +prefix|
|Operatingerror limit relative to input range<br>[%]|±0.06|
|Basic error limit (25°C)<br>Standard<br>[K]<br>Pt climatic<br>[K]|±0.6|
||±0.2|
|Temperature errors relative to input range<br>[%]|±0.001|
|Linearityerrors (no software scaling)<br>[%]|±0.02|
|Repetition accuracy(at 25°C)<br>[%]|±0.05|
|Max. line resistanceper conductor<br>[Ω]|10|
|Max.permissible input voltage<br>[V]|±30|
|Cycle time (module)<br>[ms]|š250|
2023/10 – Subject to change
193
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, analogue, for temperature inputs
**==> picture [524 x 397] intentionally omitted <==**
**----- Start of picture text -----**<br>
General technical data<br>Data format 15 bits + prefix, complement of two, binary notation in tenths of a degree<br>Cable length [m] Max. 200 (shielded)<br>Galvanic isolation Channel – channel No<br>Channel – internal bus Yes<br>LED displays Group diagnostics 1<br>Channel diagnostics 4<br>Diagnostics • Short circuit/overload, channel<br>• Parameterisation error<br>• Value falling below nominal range/full-scale value<br>• Value exceeding nominal range/full-scale value<br>• Wire break<br>Parameterisation • Unit of measurement and interference frequency suppression<br>• Diagnostic message in the event of a wire break or short circuit<br>• Limit monitoring per channel<br>• Sensor connection technology<br>• Sensor type/temperature coefficient, temperature range<br>• Limit value per channel<br>• Measured value smoothing<br>Degree of protection to EN 60529 Depending on connection block<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Materials Reinforced PA, PC<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block and connection block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 47<br>Connection and display components<br>CPX-4AE-T<br>[1] Error LED (red; module error)<br>1<br>[2] Channel-related error LEDs (red)<br>2<br>**----- End of picture text -----**<br>
|**Combinations of connection blocks and analogue module**<br>Connection blocks<br>Part no.<br>CPX-AB-4-M12X2-5POL<br>**195704**|**Combinations of connection blocks and analogue module**<br>Connection blocks<br>Part no.<br>CPX-AB-4-M12X2-5POL<br>**195704**|Temperature module|
|---|---|---|
|||CPX-4AE-T<br>h|
|CPX-AB-4-M12X2-5POL-R|**541254**|h|
|CPX-AB-8-KL-4POL|**195708**|h|
|CPX-M-AB-4-M12X2-5POL|**549367**|h|
Subject to change – 2023/10
194
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, analogue, for temperature inputs
## **Pin allocation**
**==> picture [523 x 369] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection block inputs CPX-4AE-T<br>CPX-AB-4-M12X2-5POL, CPX-AB-4-M12X2-5POL-R [1)] and CPX-M-AB-4-M12X2-5POL<br>X1.1: Input I0+ X3.1: Input I2+<br>X1.2: Input U0+ X3.2: Input U2+<br>X1.3: Input I0– X3.3: Input I2–<br>X1.4: Input U0– X3.4: Input U2–<br>X1.5: FE [2)] X3.5: FE [2)]<br>X2.1: Input I1+ X4.1: Input I3+<br>X2.2: Input U1+ X4.2: Input U3+<br>X2.3: Input I1– X4.3: Input I3–<br>X2.4: Input U1– X4.4: Input U3–<br>X2.5: FE [2)] X4.5: FE [2)]<br>CPX-AB-8-KL-4POL<br>X1.0: Input I0+ X5.0: Input I2+<br>X1 .0 .0 X5<br>.1 .1 X1.1: Input I0– X5.1: Input I2–<br>.2.3 .2.3 X1.2: Input U0– X5.2: Input U2–<br>.0 .0 X1.3: FE X5.3: FE<br>X2 .1.2 .1.2 X6 X2.0: n.c. X6.0: n.c.<br>.3 .3 X2.1: n.c. X6.1: n.c.<br>.0 .0<br>X3 .1.2 .1.2 X7 X2.2: Input U0+ X6.2: InputUI2+<br>.3 .3 X2.3: FE X6.3: FE<br>.0.1 .0.1 X3.0: Input I1+ X7.0: Input I3+<br>.2 .2 X3.1: Input I1– X7.1: Input I3–<br>X4 .3 .3 X8<br>X3.2: Input U1– X7.2: Input U3–<br>X3.3: FE X7.3: FE<br>X4.0: n.c. X8.0: n.c.<br>X4.1: n.c. X8.1: n.c.<br>X4.2: Input U1+ X8.2: Input U3+<br>X4.3: FE X8.3: FE<br>**----- End of picture text -----**<br>
- 1) Speedcon quick lock, additional shielding on metal thread
2) FE/shield additionally on metal thread
2023/10 – Subject to change
195
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, analogue, for temperature inputs
## **Ordering data**
**==> picture [524 x 410] intentionally omitted <==**
**----- Start of picture text -----**<br>
Designation Part no. Type<br>Input module, analogue<br>2 or 4 analogue temperature inputs 541486 CPX-4AE-T<br>Connection block<br>Plastic 4x socket M12, 5-pin 195704 CPX-AB-4-M12X2-5POL<br>4x socket, M12 with quick-lock technology, 5-pin 541254 CPX-AB-4-M12X2-5POL-R<br>Spring-loaded terminal, 32-pin 195708 CPX-AB-8-KL-4POL<br>Metal 4x socket M12, 5-pin 549367 CPX-M-AB-4-M12X2-5POL<br>Plug<br>Plug M12, 5-pin 175487 SEA-M12-5GS-PG7<br>Cover<br>Cover for CPX-AB-8-KL-4POL (IP65, IP67) 538219 AK-8KL<br>• 8 cable through feeds M9<br>• 1 cable through feed for multi-pin plug<br>Fittings kit 538220 VG-K-M9<br>Screening plate<br>Screening plate for M12 connections 526184 CPX-AB-S-4-M12<br>User documentation<br>User documentation German 526415 P.BE-CPX-AX-DE<br>English 526416 P.BE-CPX-AX-EN<br>Spanish 526417 P.BE-CPX-AX-ES<br>French 526418 P.BE-CPX-AX-FR<br>Italian 526419 P.BE-CPX-AX-IT<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
196
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Input module, analogue, for thermocouple
## **Function**
## **Area of application**
The CPX-4AE-TC analogue input module • Supports connection blocks with with 4 channels for temperature measM12 and terminal connection urement enables up to 4 thermocouple • Temperature module features can sensors to be connected. be parameterised The channels feature wire break and • 2-wire connection short circuit detection. • 2-wire connection for a PT1000 senIf no cold junction compensation sensor for cold junction compensation sor is being used, an internal theoreti• The temperature module is provided cal value of 25°C can be used (accurawith voltage supply for the electroncy is impaired). ics and the sensors via the interlinking block
- Temperature module protection and diagnostics through integrated electronic fuse protection
|cy is impaired).<br>ics and the sensors via the interlink-<br>ing block<br>• Temperature module protection and<br>diagnostics through integrated elec-<br>tronic fuse protection|cy is impaired).<br>ics and the sensors via the interlink-<br>ing block<br>• Temperature module protection and<br>diagnostics through integrated elec-<br>tronic fuse protection|
|---|---|
|**General technical data**<br>Type<br>CPX-4AE-TC<br>Temperature input<br>Number of analogue inputs<br>4||
||Temperature input<br>4|
|Fuseprotection (short circuit)|Internal electronic fuseper channel|
|Nominal operatingvoltage<br>[V DC]|24|
|Operatingvoltage range<br>[V DC]|18 ... 30|
|Sensor type (parameterisable for each channel with software)|• Type B +400 ... +1820°C, 8 ìV/°C<br>• Type E –270 ... +900°C, 60 ìV/°C<br>• Type J –200 ... +1200°C, 51 ìV/°C<br>• Type K –200 ... +1370°C, 40 ìV/°C<br>• Type N –200 ... +1300°C, 38 ìV/°C<br>• Type R 0 ... +1760°C, 12 ìV/°C<br>• Type S 0 ... +1760°C, 11 ìV/°C<br>• Type T –200 ... +400°C, 40 ìV/°C|
|Sensor connection technology|2-wire technology|
|Operatingerror limit relative to ambient temperature<br>[%]|Max. ±0.6|
|Basic error limit (at 25°C)<br>[%]|Max. ±0.4|
|Repetition accuracy(at 25°C)<br>[%]|±0.05|
|Max. line resistanceper conductor<br>[Ω]|10|
|Max. residual currentper module<br>[mA]|30|
|Max.permissible input voltage<br>[V]|±30|
|Internal cycle time (module)<br>[ms]|250|
2023/10 – Subject to change
197
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, analogue, for thermocouple
**==> picture [524 x 267] intentionally omitted <==**
**----- Start of picture text -----**<br>
General technical data<br>Data format • 15 bits + prefix, complement of two<br>• Binary notation in tenths of a degree<br>Cable length [m] Max. 50 (shielded)<br>Galvanic isolation Channel – channel No<br>Channel – internal bus Yes<br>LED displays Group diagnostics 1<br>Channel diagnostics 4<br>Diagnostics • Parameterisation error<br>• Wire break per channel<br>• Limit value violation per channel<br>Parameterisation • Monitoring of wire break per channel<br>• Unit of measurement<br>• Cold-junction compensation<br>• Sensor type per channel<br>• Limit value monitoring per channel<br>• Measured value smoothing<br>Degree of protection to EN 60529 Depending on connection block<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Materials Reinforced PA, PC<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block and connection block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 46<br>**----- End of picture text -----**<br>
**Connection and display components** CPX-4AE-TC [1] Error LED (red; module error) 1 [2] Channel-related error LEDs (red) ~~2~~
## **Combinations of connection blocks and analogue module**
|**Combinations of connection blocks and analogue module**|**Combinations of connection blocks and analogue module**|**Combinations of connection blocks and analogue module**|
|---|---|---|
|Connection blocks<br>CPX-AB-4-M12X2-5POL|Part no.<br>**195704**|Temperature module|
|||CPX-4AE-TC<br>h|
|CPX-AB-4-M12X2-5POL-R|**541254**|h|
|CPX-AB-8-KL-4POL|**195708**|h|
|CPX-M-AB-4-M12X2-5POL|**549367**|h|
Subject to change – 2023/10
198
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, analogue, for thermocouple
## **Pin allocation**
**==> picture [523 x 369] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection block inputs CPX-4AE-TC<br>CPX-AB-4-M12X2-5POL, CPX-AB-4-M12X2-5POL-R [1)] and CPX-M-AB-4-M12X2-5POL<br>X1.1: Cold junction compensation 0+ X3.1: Cold junction compensation 2+<br>X1.2: Input signal U0+ X3.2: Input signal U2+<br>X1.3: Cold junction compensation 0– X3.3: Cold junction compensation 2–<br>X1.4: Input signal U0– X3.4: Input signal U2–<br>X1.5: FE [2)] X3.5: FE [2)]<br>X2.1: Cold junction compensation 1+ X4.1: Cold junction compensation 3+<br>X2.2: Input signal U1+ X4.2: Input signal U3+<br>X2.3: Cold junction compensation 1– X4.3: Cold junction compensation 3–<br>X2.4: Input signal U1– X4.4: Input signal U3–<br>X2.5: FE [2)] X4.5: FE [2)]<br>CPX-AB-8-KL-4POL<br>X1.0: Cold junction compensation 0+ X5.0: Cold junction compensation 2+<br>X1 .0 .0 X5<br>.1 .1 X1.1: Cold junction compensation 0– X5.1: Cold junction compensation 2–<br>.2.3 .2.3 X1.2: Input signal U0– X5.2: Input signal U2–<br>.0 .0 X1.3: FE X5.3: FE<br>X2 .1.2 .1.2 X6 X2.0: n.c. X6.0: n.c.<br>.3 .3 X2.1: n.c. X6.1: n.c.<br>.0 .0<br>X3 .1.2 .1.2 X7 X2.2: Input signal U0+ X6.2: Input signal U2+<br>.3 .3 X2.3: FE X6.3: FE<br>.0.1 .0.1 X3.0: Cold junction compensation 1+ X7.0: Cold junction compensation 3+<br>.2 .2 X3.1: Cold junction compensation 1– X7.1: Cold junction compensation 3–<br>X4 .3 .3 X8<br>X3.2: Input signal U1– X7.2: Input signal U3–<br>X3.3: FE X7.3: FE<br>X4.0: n.c. X8.0: n.c.<br>X4.1: n.c. X8.1: n.c.<br>X4.2: Input signal U1+ X8.2: Input signal U3+<br>X4.3: FE X8.3: FE<br>**----- End of picture text -----**<br>
- 1) Speedcon quick lock, additional shielding on metal thread
2) FE/shield additionally on metal thread
2023/10 – Subject to change
199
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Input module, analogue, for thermocouple
## **Ordering data**
**==> picture [524 x 461] intentionally omitted <==**
**----- Start of picture text -----**<br>
Designation Part no. Type<br>Input module, analogue<br>4 analogue temperature inputs, with 2-wire connection for a PT1000 sensor for cold junction compen- 553594 CPX-4AE-TC<br>sation<br>Connection block<br>Plastic 4x socket M12, 5-pin 195704 CPX-AB-4-M12X2-5POL<br>4x socket, M12 with quick-lock technology, 5-pin 541254 CPX-AB-4-M12X2-5POL-R<br>Spring-loaded terminal, 32-pin 195708 CPX-AB-8-KL-4POL<br>Metal 4x socket M12, 5-pin 549367 CPX-M-AB-4-M12X2-5POL<br>Cold junction compensation<br>PT1000 temperature sensor for cold junction compensation 553596 CPX-W-PT1000<br>Plug<br>Plug M12, 5-pin 175487 SEA-M12-5GS-PG7<br>Cover<br>Cover for CPX-AB-8-KL-4POL (IP65, IP67) 538219 AK-8KL<br>• 8 cable through feeds M9<br>• 1 cable through feed for multi-pin plug<br>Fittings kit 538220 VG-K-M9<br>Screening plate<br>Screening plate for M12 connections 526184 CPX-AB-S-4-M12<br>User documentation<br>User documentation German 526415 P.BE-CPX-AX-DE<br>English 526416 P.BE-CPX-AX-EN<br>Spanish 526417 P.BE-CPX-AX-ES<br>French 526418 P.BE-CPX-AX-FR<br>Italian 526419 P.BE-CPX-AX-IT<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
200
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Output module, analogue
## **Function**
Analogue modules control devices with a standard analogue interface such as proportional valves, etc. Depending on the connection block selected, the analogue module supports various connection concepts with different numbers of sockets or terminals.
## **Area of application**
- Analogue module for 0 ... 10 V, 0 ... 20 mA or 4 ... 20 mA
- Supports connection blocks with Sub-D, terminal connection and M12 connection
- Analogue module features can be parameterised
- Different data formats available
- Operation with and without galvanic isolation possible
- The analogue module receives the voltage supply for the electronics and the actuators from the interlinking block
- Analogue module protection and diagnostics through integrated electronic fuse protection
## **General technical data**
|and the actuators from the interlink-<br>ing block<br>• Analogue module protection and di-<br>agnostics through integrated elec-<br>tronic fuse protection|and the actuators from the interlink-<br>ing block<br>• Analogue module protection and di-<br>agnostics through integrated elec-<br>tronic fuse protection|and the actuators from the interlink-<br>ing block<br>• Analogue module protection and di-<br>agnostics through integrated elec-<br>tronic fuse protection|
|---|---|---|
|**General technical data**<br>Type<br>CPX-2AA-U-I<br>Voltage output<br>Current output<br>Number of analogue outputs<br>2|||
||Voltage output<br>Current output<br>2||
|Max. actuator supply per module<br>[A]|2.8||
|Fuseprotection|Internal electronic fuse for actuator supply||
|Current consumption from 24 V sensor supply(at full load)<br>[mA]|Max. 150||
|Current consumption from 24 V actuator supply(at full load)<br>[A]|4 ... 10||
|Supplyvoltage for actuators<br>[V DC]|24 ±25%||
|Signal range (parameterisable for each channel with<br>DIL switch or software)|0 ... 10 V DC|0 ... 20 mA<br>4 ... 20 mA|
|Resolution<br>[bit]|12||
|Number of units|4096||
|Absolute accuracy<br>[%]|±0.6||
|Linearityerrors (no software scaling)<br>[%]|±0.1||
|Repetition accuracy(at 25°C)<br>[%]|0.05||
|Encoder selection<br>Load resistance for ohmic load<br>[kΩ]<br>Load resistance for capacitive load<br>[μF]<br>Load resistance for inductive load<br>[mH]<br>Short circuitprotection for analogue output<br>Short circuit current of analogue output<br>[mA]<br>Open circuit voltage<br>[V DC]<br>Destruction limit against externally applied<br>voltage<br>[V DC]<br>Actuator connection|Min. 1|Max. 0.5|
||Max. 1|–|
||–|Max. 1|
||Yes|–|
||Approx. 20|–|
||–|18|
||15||
||2 wires||
|Cycle time (module)<br>[ms]|š4||
2023/10 – Subject to change
201
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Output module, analogue
## **General technical data**
**==> picture [524 x 453] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type CPX-2AA-U-I<br>Voltage output Current output<br>Response time For ohmic load [ms] 0.1 0.1<br>For capacitive load [ms] 0.7 –<br>For inductive load [ms] – 0.5<br>Data format 15 bits + prefix, linear scaling<br>12 bits right-justified<br>12 bits left-justified, S7 compatible<br>12 bits left-justified, S5 compatible<br>Cable length [m] Max. 30 (shielded)<br>LED displays Group diagnostics 1<br>Channel diagnostics Yes, via flashing frequency of group diagnostics<br>Diagnostics • Short circuit/overload, actuator supply<br>• Parameterisation error<br>• Value falling below nominal range/full-scale value<br>• Value exceeding nominal range/full-scale value<br>• Wire break<br>Parameterisation • Short circuit monitoring, actuator supply<br>• Short circuit monitoring, analogue output<br>• Behaviour after short circuit, actuator supply<br>• Data format<br>• Lower limit value/full-scale value<br>• Upper limit value/full-scale value<br>• Monitoring value falling below nominal range/full-scale value<br>• Monitoring value exceeding nominal range/full-scale value<br>• Monitoring wire break<br>• Signal range<br>Degree of protection to EN 60529 Depending on connection block<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Materials Reinforced PA, PC<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block and connection block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 49<br>Connection and display components<br>CPX-2AA-U-I<br>[1] Error LED (red; module error)<br>1<br>2<br>AO<br>**----- End of picture text -----**<br>
|**Combinations of connection blocks and analogue module**<br>Connection blocks<br>Part no.<br>CPX-AB-4-M12X2-5POL<br>**195704**|**Combinations of connection blocks and analogue module**<br>Connection blocks<br>Part no.<br>CPX-AB-4-M12X2-5POL<br>**195704**|Analogue module|
|---|---|---|
|||CPX-2AA-U-I<br>h|
|CPX-AB-4-M12X2-5POL-R|**541254**|h|
|CPX-AB-8-KL-4POL|**195708**|h|
|CPX-AB-1-SUB-BU-25POL|**525676**|h|
|CPX-M-AB-4-M12X2-5POL|**549367**|h|
Subject to change – 2023/10
202
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Output module, analogue
## **Pin allocation**
**==> picture [523 x 540] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection block outputs CPX-2AA-U-I<br>CPX-AB-4-M12X2-5POL, CPX-AB-4-M12X2-5POL-R [1)] , CPX-M-AB-4-M12X2-5POL<br>X1.1: 24 VOUT X3.1: 24 VOUT<br>X1.2: Output U0+ X3.2: Output U1+<br>X1.3: 0 VOUT X3.3: 0 VOUT<br>X1.4: Output GND X3.4: Output GND<br>X1.5: FE [2)] X3.5: FE [2)]<br>X2.1: 24 VOUT X4.1: 24 VOUT<br>X2.2: Output I0+ X4.2: Output I1+<br>X2.3: 0 VOUT X4.3: 0 VOUT<br>X2.4: Output GND X4.4: Output GND<br>X2.5: FE [2)] X4.5: FE [2)]<br>CPX-AB-8-KL-4POL<br>X1.0: 24 VOUT X5.0: 24 VOUT<br>X1 .0 .0 X5<br>.1 .1 X1.1: 0 VOUT X5.1: 0 VOUT<br>.2.3 .2.3 X1.2: Output GND X5.2: Output GND<br>.0 .0 X1.3: FE X5.3: FE<br>X2 .1.2 .1.2 X6 X2.0: n.c. X6.0: n.c.<br>.3 .3 X2.1: n.c. X6.1: n.c.<br>.0 .0<br>X3 .1.2 .1.2 X7 X2.2: Output U0+ X6.2: Output U1+<br>.3 .3 X2.3: FE X6.3: FE<br>.0.1 .0.1 X3.0: 24 VOUT X7.0: 24 VOUT<br>X4 .2.3 .2.3 X8 X3.1: 0 VOUT X7.1: 0 VOUT<br>X3.2: Output GDN X7.2: Output GND<br>X3.3: FE X7.3: FE<br>X4.0: n.c. X8.0: n.c.<br>X4.1: n.c. X8.1: n.c.<br>X4.2: Output I0+ X8.2: Output I1+<br>X4.3: FE X8.3: FE<br>CPX-AB-1-SUB-BU-25POL<br>1: Output GND 14: Output GND<br>2: Output U0+ 15: Output U1+<br>3: Output GND 16: Output GND<br>4: Output I0+ 17: Output I1+<br>5: n.c. 18: 24 VOUT<br>6: n.c. 19: n.c.<br>7: n.c. 20: 24 VOUT<br>8: n.c. 21: n.c.<br>9: 24 VOUT 22: 0 VOUT<br>10: 24 VOUT 23: 0 VOUT<br>11: 0 VOUT 24: 0 VOUT<br>12: 0 VOUT 25: FE<br>13: Shielding [3)] Housing: FE<br>**----- End of picture text -----**<br>
- 1) Speedcon quick lock, additional shielding on metal thread
- 2) FE/shield additionally on metal thread
- 3) Connect shield to functional earth FE
2023/10 – Subject to change
203
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Output module, analogue
## **Ordering data**
**==> picture [524 x 517] intentionally omitted <==**
**----- Start of picture text -----**<br>
Designation Part no. Type<br>Output module, analogue<br>2 analogue current or voltage outputs 526170 CPX-2AA-U-I<br>Connection block<br>Plastic 4x socket M12, 5-pin 195704 CPX-AB-4-M12X2-5POL<br>4x socket, M12 with quick-lock technology, 5-pin 541254 CPX-AB-4-M12X2-5POL-R<br>Spring-loaded terminal, 32-pin 195708 CPX-AB-8-KL-4POL<br>1x socket, Sub-D, 25-pin 525676 CPX-AB-1-SUB-BU-25POL<br>Metal 4x socket M12, 5-pin 549367 CPX-M-AB-4-M12X2-5POL<br>Plug<br>Plug M12, 5-pin 175487 SEA-M12-5GS-PG7<br>Sub-D plug, 25-pin 527522 SD-SUB-D-ST25<br>Connecting cable<br>Modular system for a choice of connecting cables – NEBU- ...<br>a Internet: nebu<br>Cover<br>Cover for CPX-AB-8-KL-4POL (IP65, IP67) 538219 AK-8KL<br>• 8 cable through feeds M9<br>• 1 cable through feed for multi-pin plug<br>Fittings kit 538220 VG-K-M9<br>Screening plate<br>Screening plate for M12 connections 526184 CPX-AB-S-4-M12<br>User documentation<br>User documentation German 526415 P.BE-CPX-AX-DE<br>English 526416 P.BE-CPX-AX-EN<br>Spanish 526417 P.BE-CPX-AX-ES<br>French 526418 P.BE-CPX-AX-FR<br>Italian 526419 P.BE-CPX-AX-IT<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
204
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – PROFIsafe shut-off module
## **Area of application**
## **Function**
- The PROFIsafe shut-off module inter• Output module for 24 V DC supply rupts the contact rails of the interlinkvoltage ing block for valves and outputs. The • Shut-off module for supply voltage supply voltage for valves can be for valves switched by the module within the CPX • Can only be used with PROFINET or terminal and via a connection block to PROFIBUS bus nodes two consuming devices. Actuation • The shut-off module is supplied takes place via the bus node (PROFwith voltage for the electronics and INET) of the CPX terminal. the outputs by the interlinking block
**==> picture [257 x 114] intentionally omitted <==**
- The outputs are supplied from the power supply for valves (VValves)
## **General technical data**
**==> picture [523 x 416] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type CPX-FVDA-P2<br>Number of outputs 2<br>Note on outputs 1 internal channel for switching off the supply voltage for valves<br>2 external outputs<br>Max. address capacity Inputs [B] 6<br>Outputs [B] 6<br>Maximum cable length [m] 200<br>Max. power supply Per module [A] 5<br>Per channel [A] 1.5<br>Fuse protection (short circuit) Internal electronic fuse per channel<br>Current consumption of module [mA] Typically 65 (power supply for valves)<br>[mA] Typically 25 (power supply for electronics)<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 20.4 ... 28.8<br>Voltage drop per channel [V] 0.6<br>Residual ripple [Vss] 2 within voltage range<br>Load capacity to FE [nF] 400<br>Max. response time to shut-off command [ms] 23<br>Galvanic isolation Channel – channel No<br>Channel – internal bus Yes, with intermediate supply<br>Switching logic Outputs P-M switching<br>Safety integrity level Safe switch-off, SIL3<br>Performance Level Safe switch-off/category 3, Performance Level e<br>Failure rate per hour (PFH) 1.0x 10 [-9]<br>Certificate issuing authority 01/205/50294/13<br>LED displays Group diagnostics 1<br>Channel diagnostics 3<br>Channel status 3<br>Failsafe protocol active 1<br>Diagnostics • Short circuit/overload per channel<br>• Undervoltage of valves<br>• Cross circuit<br>• Wire break per channel<br>Parameterisation • Monitoring of wire break per channel<br>• Diagnostic behaviour<br>Degree of protection to EN 60529 Depending on connection block<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block and connection block) W x L x H [mm] 50 x 107 x 55<br>Product weight [g] 50<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
205
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – PROFIsafe shut-off module
**==> picture [524 x 170] intentionally omitted <==**
**----- Start of picture text -----**<br>
Materials<br>Housing Reinforced PA, PC<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Operating and environmental conditions<br>Ambient temperature [°C] –5 ... +50<br>Storage temperature [°C] –20 ... +70<br>CE marking (see declaration of conformity) [1)] To EU Machinery Directive<br>To EU EMC Directive<br>To EU RoHS Directive<br>UKCA marking (see declaration of conformity) [1)] To UK instructions for machines<br>To UK instructions for EMC<br>To UK RoHS instructions<br>Certification c UL us - Recognized (OL)<br>**----- End of picture text -----**<br>
- 1) Additional information at: www.festo.com/catalogue/... d Support/Downloads.
**==> picture [522 x 117] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection and display components<br>CPX-FVDA-P2<br>[1] Status LEDs (yellow): [2] Channel-related error LEDs (red)<br>4 0: Supply voltage for valves [3] Fail-safe protocol active (green)<br>1: X1 [4] Error LED (red, module error)<br>2: X2<br>1 2 3<br>**----- End of picture text -----**<br>
## **Combinations of bus nodes/control blocks and PROFIsafe shut-off module**
|**Combinations of bus nodes/control blocks and PROFIsafe shut-off module**|**Combinations of bus nodes/control blocks and PROFIsafe shut-off module**|**Combinations of bus nodes/control blocks and PROFIsafe shut-off module**|
|---|---|---|
|Bus node/control block<br>CPX-FB13|Part no.<br>**195740**|PROFIsafe shut-off module|
|||CPX-FVDA-P2<br>h|
|CPX-FB43|**8110369**|h|
|CPX-M-FB44|**8110370**|h|
|CPX-M-FB45|**8110371**|h|
## - **Note** H-
The PROFIsafe shut-off module CPX-FVDA-P2 can only be integrated as of software release 21 or release 30 (in the case of CPX-FB13).
Subject to change – 2023/10
206
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – PROFIsafe shut-off module
**==> picture [523 x 449] intentionally omitted <==**
**----- Start of picture text -----**<br>
Combinations of connection blocks and PROFIsafe shut-off module<br>Connection blocks Part no. PROFIsafe shut-off module<br>CPX-FVDA-P2<br>CPX-M-AB-4-M12X2-5POL 549367 h<br>CPX-AB-8-KL-4POL 195708 h<br>Pin allocation<br>Connection block outputs CPX-FVDA-P2<br>CPX-M-AB-4-M12X2-5POL<br>X1.1: 0 VOUT 1 (cannot be switched off) X3.1: n.c.<br>X1.2: 24 VOUT 1 (cannot be switched off) X3.2: n.c.<br>X1.3: 0 VOUT 1 (can be switched off via fieldbus) X3.3: n.c.<br>X1.4: 24 VOUT 1 (can be switched off via fieldbus) X3.4: n.c.<br>X1.5: FE X3.5: FE<br>X2.1: 0 VOUT 2 (cannot be switched off) X4.1: n.c.<br>X2.2: 24 VOUT 2 (cannot be switched off) X4.2: n.c.<br>X2.3: 0 VOUT 2 (can be switched off via fieldbus) X4.3: n.c.<br>X2.4: 24 VOUT 2 (can be switched off via fieldbus) X4.4: n.c.<br>X2.5: FE X4.5: FE<br>CPX-AB-8-KL-4POL<br>X1.0: 0 VOUT 1 (cannot be switched off) X5.0: n.c.<br>X1 .0 .0 X5<br>.1 .1 X1.1: 0 VOUT 1 (can be switched off via fieldbus) X5.1: n.c.<br>.2.3 .2.3 X1.2: 24 VOUT 1 (can be switched off via fieldbus) X5.2: n.c.<br>.0 .0 X1.3: FE X5.3: n.c.<br>X2 .1.2 .1.2 X6 X2.0: n.c. X6.0: n.c.<br>.3 .3 X2.1: n.c. X6.1: n.c.<br>.0 .0<br>X3 .1.2 .1.2 X7 X2.2: 24 VOUT 1 (cannot be switched off) X6.2: n.c.<br>.3 .3 X2.3: FE X6.3: n.c.<br>.0.1 .0.1 X3.0: 0 VOUT 2 (cannot be switched off) X7.0: n.c.<br>X4 .2.3 .2.3 X8 X3.1: 0 VOUT 2 (can be switched off via fieldbus) X7.1: n.c.<br>X3.2: 24 VOUT 2 (can be switched off via fieldbus) X7.2: n.c.<br>X3.3: FE X7.3: n.c.<br>X4.0: n.c. X8.0: n.c.<br>X4.1: n.c. X8.1: n.c.<br>X4.2: 24 VOUT 2 (cannot be switched off) X8.2: n.c.<br>X4.3: FE X8.3: n.c.<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
207
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – PROFIsafe shut-off module
**==> picture [524 x 304] intentionally omitted <==**
**----- Start of picture text -----**<br>
Combinations of interlinking blocks and PROFIsafe shut-off module<br>Interlinking blocks Part no. PROFIsafe shut-off module<br>CPX-FVDA-P2<br>CPX-GE-EV-S 195746 –<br>CPX-GE-EV-S-VL 8022170 –<br>CPX-GE-EV-S-7/8-4POL 541248 –<br>CPX-GE-EV-S-7/8-5POL 541244 –<br>CPX-GE-EV-S-7/8-5POL-VL 8022172 –<br>CPX-M-GE-EV-S-7/8-CIP-4P 568956 –<br>CPX-M-GE-EV-S-7/8-5POL 550208 –<br>CPX-M-GE-EV-S-7/8-5POL-VL 8022165 –<br>CPX-M-GE-EV-S-M12-5POL 8098392 –<br>CPX-M-GE-EV-S-PP-5POL 563057 –<br>CPX-GE-EV 195742 –<br>CPX-M-GE-EV 550206 –<br>CPX-M-GE-EV-FVO 567806 h<br>CPX-GE-EV-Z 195744 –<br>CPX-GE-EV-Z-VL 8022166 –<br>CPX-GE-EV-Z-7/8-4POL 541250 –<br>CPX-GE-EV-Z-7/8-5POL 541246 –<br>CPX-GE-EV-Z-7/8-5POL-VL 8022173 –<br>CPX-M-GE-EV-Z-7/8-5POL 550210 –<br>CPX-M-GE-EV-Z-7/8-5POL-VL 8022158 –<br>CPX-M-GE-EV-Z-PP-5POL 563058 –<br>CPX-GE-EV-V 533577 –<br>CPX-GE-EV-V-VL 8022171 –<br>CPX-GE-EV-V-7/8-4POL 541252 –<br>CPX-M-GE-EV-W-M12-5POL 8098391 –<br>**----- End of picture text -----**<br>
## **General technical data**
**==> picture [524 x 144] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type CPX-M-GE-EV-FVO<br>Nominal operating voltage [V DC] 24<br>Acceptable current load (per contact/contact rail) [A] 16<br>Degree of protection to EN 60529 Depending on connection block<br>Ambient temperature [°C] –5 ... +50<br>Certification c UL us - Recognized (OL)<br>Note on materials RoHS-compliant<br>Materials Die-cast aluminium<br>PWIS conformity VDMA24364-B2-L<br>Type of mounting Angled fitting<br>Grid dimension [mm] 50<br>Dimensions W x L x H [mm] 50 x 107 x 35<br>Product weight [g] 170<br>**----- End of picture text -----**<br>
## **Pin allocation**
**==> picture [523 x 169] intentionally omitted <==**
**----- Start of picture text -----**<br>
Circuitry Pin Allocation<br>– –<br>– –<br>– –<br>– –<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
208
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – PROFIsafe shut-off module
**==> picture [523 x 520] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Description Part no. Type<br>PROFIsafe shut-off module<br>Metal connection block 4x socket, M12, 5-pin 549367 CPX-M-AB-4-M12X2-5POL<br>Plastic connection block Spring-loaded terminal, 32-pin 195708 CPX-AB-8-KL-4POL<br>Electronics module PROFINET, PROFIBUS 1971599 CPX-FVDA-P2<br>(can only be used with CPX-M-GE-EV-FVO)<br>Metal interlinking block 567806 CPX-M-GE-EV-FVO<br>(for CPX-FVDA-P2 only)<br>Distributor<br>Modular system for all types of sensor/actuator distributor – NEDY- ...<br>a Internet: nedy<br>1x plug M12, 4-pin 2x socket M12, 5-pin 8005310 NEDY-L2R1-V1-M12G5-N-M12G4<br>Plug<br>Plug M12, PG7 18666 SEA-GS-7<br>M12, PG7, 4-pin for cable @ 2.5 mm 192008 SEA-4GS-7-2.5<br>M12, PG9 18778 SEA-GS-9<br>M12 for 2 cables 18779 SEA-GS-11-DUO<br>M12 for 2 cables, 5-pin 192010 SEA-5GS-11-DUO<br>M12, 5-pin 175487 SEA-M12-5GS-PG7<br>Connecting cable<br>Modular system for a choice of connecting cables – NEBU- ...<br>a Internet: nebu<br>User documentation<br>User documentation for PROFIsafe shut-off module German 8022606 CPX-FVDA-P2-DE<br>English 8022607 CPX-FVDA-P2-EN<br>Spanish 8022608 CPX-FVDA-P2-ES<br>French 8022609 CPX-FVDA-P2-FR<br>Italian 8022610 CPX-FVDA-P2-IT<br>Chinese 8022611 CPX-FVDA-P2-ZH<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
209
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – End plate with system supply
## **Area of application**
## **Function**
End plates form the outer edge of the • 24 V DC supply voltage for the elecCPX terminal. tronics of the CPX terminal The earth connection and mounting • 24 V DC supply voltage for inputs holes for wall or H-rail mounting are lo• 24 V DC supply voltage for valves cated on the left-hand end plate. • 24 V DC supply voltage for outputs The end plate with system supply has contact rails from which the other CPX components on the interlinking modules are supplied with power.
**==> picture [256 x 114] intentionally omitted <==**
**==> picture [524 x 353] intentionally omitted <==**
**----- Start of picture text -----**<br>
General technical data<br>Electrical connection Plug, 7-pin<br>Type of mounting Tie rods<br>Power supply System supply<br>Maximum power supply [A] 12<br>Product weight [g] 145<br>Materials<br>Housing Die-cast aluminium, painted<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Operating and environmental conditions<br>Certification c UL us - Recognized (OL)<br>Pin allocation<br>Circuitry Pin Allocation<br>Plug, 7-pin<br>[1] 0 V power supply for valves<br>1<br>2 [2] 24 V DC load voltage supply for valves<br>3<br>[3] 0 V power supply for outputs<br>4<br>5 [4] 24 V DC load voltage supply for outputs<br>6<br>[5] 0 V power supply for electronics and sensors<br>7<br>[6] 24 V DC power supply for electronics and sensors<br>[7] FE<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
210
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – End plate with system supply
**==> picture [523 x 146] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Part no. Type<br>End plate with system supply<br>End plate for CPX terminal in plastic design 576315 CPX-EPL-EV-S<br>Terminal strip<br>Plug, 7-pin, straight Spring-loaded ter- 576319 NECU-L3G7-C1<br>minal<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
211
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – End plate with extension
## **Area of application**
## **Function**
End plates form the outer edge of the • Separation of long CPX terminals CPX terminal. into two shorter units
The earth connection and mounting • Adaptation for installation in a conholes for wall or H-rail mounting are lotrol cabinet cated on the left-hand end plates.
The end plates with extension enable the CPX terminal to be separated into two interconnected terminals. Control is provided via a common bus node or control block.
**==> picture [256 x 114] intentionally omitted <==**
## **General technical data**
**==> picture [524 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type CPX-EP... CPX-M-EP...<br>Type of mounting Tie rods Angled fitting<br>Maximum power supply [A] 6 6<br>Materials<br>Type CPX-EP... CPX-M-EP...<br>Housing Die-cast aluminium, painted Die-cast aluminium<br>Note on materials RoHS-compliant RoHS-compliant<br>PWIS conformity VDMA24364-B2-L VDMA24364-B2-L<br>Operating and environmental conditions<br>Certification c UL us - Recognized (OL)<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
212
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – End plate with extension
**Pin allocation – End plate with extension**
**==> picture [523 x 204] intentionally omitted <==**
**----- Start of picture text -----**<br>
Circuitry Pin Allocation Pin Circuitry<br>Right-hand end plate (first row) Round plug, 8-pin Left-hand end plate (second row)<br>M12<br>1 0 V DC supply voltage for electronics 1<br>and sensors<br>2 0 V DC load voltage supply for valves 2<br>3 24 V DC load voltage supply for valves 3<br>4 24 V DC power supply for electronics 4<br>and sensors<br>5 Bus signal 5<br>6 Bus signal 6<br>7 Bus signal 7<br>8 Bus signal 8<br>Housing FE Housing<br>**----- End of picture text -----**<br>
## **Ordering data**
**==> picture [523 x 160] intentionally omitted <==**
**----- Start of picture text -----**<br>
Weight Part no. Type<br>[g]<br>End plate with extension<br>For CPX terminal in plastic design First row, right-hand end plate 190 576313 CPX-EPR-EV-X<br>Second row, left-hand end plate 175 576314 CPX-EPL-EV-X<br>For CPX terminal in metal design First row, right-hand end plate 190 576316 CPX-M-EPR-EV-X<br>Second row, left-hand end plate 175 576317 CPX-M-EPL-EV-X<br>Connecting cable<br>8-pin 0.25 m 47 564189 NEBC-F12G8-KH-0.25-N-S-F12G8<br>0.5 m 69 564190 NEBC-F12G8-KH-0.5-N-S-F12G8<br>1 m 113 564191 NEBC-F12G8-KH-1-N-S-F12G8<br>1.5 m 154 564192 NEBC-F12G8-KH-1.5-N-S-F12G8<br>2 m 200 576015 NEBC-F12G8-KH-2-N-S-F12G8<br>3 m 280 576636 NEBC-F12G8-KH-3-N-S-F12G8<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
213
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Interlinking block with system supply
## **Function**
Interlinking blocks ensure the electrical supply of all other CPX modules. They have contact rails, from which the other CPX components on the interlinking modules are supplied with power. Internal division of the power supply makes it possible to switch off specific areas of the sensors and actuators individually.
## **Area of application**
- 24 V DC supply voltage for the electronics of the CPX terminal
- 24 V DC supply voltage for inputs
- 24 V DC supply voltage for valves
- 24 V DC supply voltage for outputs
## **General technical data**
Nominal operating voltage [V DC] 24 Degree of protection to EN 60529 Depending on connection block Ambient temperature [°C] –5 ... +50 Note on materials RoHS-compliant PWIS conformity VDMA24364-B2-L Grid dimension [mm] 50 Dimensions W x L x H [mm] 50 x 107 x 35 **Technical data – Plastic interlinking blocks** Type CPX-GE-EV-S -VL -7/8-4POL -7/8-5POL -7/8-5POL-VL Electrical connection M18 M18 7/8", 4-pin 7/8", 5-pin 7/8", 5-pin Power supply Sensors and electronics [A] Max. 16 Max. 8 Max. 10 Max. 8 Max. 8 Valves and outputs [A] Max. 16 Max. 8 Max. 10 Max. 8 Max. 8 Corrosion resistance class CRC[1)] 1 Type of mounting Tie rods Materials PA-reinforced Product weight [g] 125 ~~SS~~ 1) Additional information: www.festo.com/x/topic/kbk
Subject to change – 2023/10
214
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Interlinking block with system supply
**==> picture [523 x 254] intentionally omitted <==**
**----- Start of picture text -----**<br>
Technical data – Metal interlinking blocks<br>Type CPX-M-GE-EV-S<br>-7/8-CIP-4P -7/8-5POL -M12-5POL -7/8-5POL-VL -PP-5POL<br>Electrical connection 7/8", 4-pin 7/8", 5-pin Plug 7/8", 5-pin AIDA push-pull,<br>M12x1 5-pin<br>5-pin<br>L-coded<br>Power supply Sensors and electronics [A] Max. 10 Max. 8 Max. 16 Max. 8 Max. 16<br>Valves and outputs [A] Max. 10 Max. 8 Max. 16 Max. 8 Max. 16<br>Corrosion resistance class CRC [1)] 0<br>Type of mounting Angled fitting<br>Materials Die-cast aluminium<br>Certification – – c UL - Recog- – –<br>nized (OL)<br>Product weight [g] 187 187 266 187 279<br>1) Additional information: www.festo.com/x/topic/kbk<br>- Note<br>H-<br>Points to note about the interlinking • Must be mounted as the first mod- • The functional earth (FE) must be • Only permitted as an interlinking<br>block CPX-M-GE-EV-S-7/8-CIP-4P: ule to the right of the left-hand end connected via the left-hand end block to a bus node<br>plate plate<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
215
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Interlinking block with system supply
## **Pin allocation – Plastic interlinking blocks**
**==> picture [524 x 504] intentionally omitted <==**
**----- Start of picture text -----**<br>
Circuitry Pin Allocation<br>Round plug, 4-pin<br>M18<br>1 24 V DC power supply for electronics and sensors<br>2 24 V DC load voltage supply for valves and outputs<br>3 0 V<br>4 FE<br>7/8"<br>A 24 V DC supply voltage for electronics and sensors<br>B 24 V DC load voltage supply for valves and outputs<br>C FE<br>D 0V<br>Round plug, 5-pin<br>7/8"<br>1 0 V valves and outputs<br>2 0 V electronics and sensors<br>3 FE<br>4 24 V DC power supply for electronics and sensors<br>5 24 V DC load voltage supply for valves and outputs<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
216
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Interlinking block with system supply
**==> picture [523 x 506] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pin allocation – Metal interlinking blocks<br>Circuitry Pin Allocation<br>Round plug, 4-pin<br>7/8"<br>A 24 V DC supply voltage for electronics and sensors<br>B 24 V DC load voltage supply for valves and outputs<br>C 0 V DC supply voltage for electronics and sensors<br>D 0 V DC load voltage supply for valves and outputs<br>- Note<br>H-<br>The functional earth (FE) must be connected via the left-<br>hand end plate.<br>Round plug, 5-pin<br>7/8"<br>1 0 V valves and outputs<br>2 0 V electronics and sensors<br>3 FE<br>4 24 V DC power supply for electronics and sensors<br>5 24 V DC load voltage supply for valves and outputs<br>M12<br>1 24 V DC power supply for electronics and sensors<br>2 0 V valves and outputs<br>3 0 V electronics and sensors<br>4 24 V DC load voltage supply for valves and outputs<br>FE FE<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
217
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Interlinking block with system supply
**==> picture [524 x 263] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pin allocation – Metal interlinking blocks<br>Circuitry Pin Allocation<br>5-pin push-pull plug<br>Plug pattern to PROFINET specification<br>1 24 V DC power supply for electronics and sensors<br>2 0 V electronics and sensors<br>3 24 V DC load voltage supply for valves and outputs<br>4 0 V valves and outputs<br>5 FE<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
218
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Interlinking block with system supply
|Data sheet – Interlinking block with system supply|Data sheet – Interlinking block with system supply|Data sheet – Interlinking block with system supply|Data sheet – Interlinking block with system supply|Data sheet – Interlinking block with system supply|Data sheet – Interlinking block with system supply|
|---|---|---|---|---|---|
|**Ordering data**<br>Designation<br>Part no.<br>Type<br>Interlinkingblock with system supply<br>~~ee~~<br>~~S||rp~~<br>~~|_|}~~||||||
|~~S|~~<br><< <A Z|~~|_|}~~<br>~~CO~~|M18 connection, plastic interlinking block<br>~~S||~~<br>~~|_|}~~<br>~~CO~~|4-pin<br>~~|~~<br>~~|_|}~~<br>~~SS~~|–<br>~~rp~~<br>~~|_|}~~|**195746**<br>~~ee~~<br>~~rp~~|**CPX-GE-EV-S**<br>~~ee~~<br>~~rp~~|
||||For ATEX environment<br>~~rp~~<br>~~|_|}~~<br>~~SS~~|**8022170**<br>~~ee~~<br>~~rp~~<br>~~SS~~|**CPX-GE-EV-S-VL**<br>~~ee~~<br>~~rp~~<br>~~SS~~|
|~~S|~~<br>~~|_|}~~<br>~~CO~~<br>S>.<br>~~6~~a|7/8" connection, plastic interlinking block<br>~~S| |~~<br>~~|_|}~~<br>~~CO~~|4-pin<br>~~| ~~<br>~~|_|}~~<br>~~SS~~|–<br> ~~rp~~<br>~~|_|}~~<br>~~SS~~<br>~~a~~|**541248**<br>~~ee~~<br>~~rp~~<br>~~SS~~|**CPX-GE-EV-S-7/8-4POL**<br>~~ee~~<br>~~rp~~<br>~~SS~~|
|||5-pin<br>~~|_|}~~<br>~~SS~~|–<br>~~|_|}~~<br>~~SS~~<br>~~a~~|**541244**<br>~~SS~~|**CPX-GE-EV-S-7/8-5POL**<br>~~SS~~|
||||For ATEX environment<br>~~|_|}~~<br>~~SS~~<br>~~a~~|**8022172**<br>~~SS~~|**CPX-GE-EV-S-7/8-5POL-VL**<br>~~SS~~|
||7/8" connection, metal interlinking block<br>~~|_|}~~<br>~~CO~~|4-pin<br>~~|_|}~~<br>~~SS~~|–<br>~~|_|}~~<br>~~SS~~<br>~~a~~|**568956**<br>~~SS~~|**CPX-M-GE-EV-S-7/8-CIP-4P**<br>~~SS~~|
|||5-pin<br>~~|_|}~~<br>~~SS~~<br>~~=~~|–<br>~~|_|}~~<br>~~SS~~|**550208**<br>~~SS~~|**CPX-M-GE-EV-S-7/8-5POL**<br>~~SS~~|
||||For ATEX environment<br>~~SS~~|**8022165**<br>~~SS~~|**CPX-M-GE-EV-S-7/8-5POL-VL**<br>~~SS~~|
|~~CO~~<br>~~6~~<br>IN<br>ob|M12x1 L-coded connection, metal interlinking block<br>~~CO~~|5-pin<br>~~SS~~<br>~~=~~|–<br>~~SS~~|**8098392**<br>~~SS~~|**CPX-M-GE-EV-S-M12-5POL**<br>~~SS~~|
|EE<br>~~Fo~~|Push-pull plug connection (AIDA), metal interlinking block<br>~~Fo~~|5-pin<br>~~an~~|–<br>~~an~~|**563057**<br>~~in i~~|**CPX-M-GE-EV-S-PP-5POL**<br>~~i~~|
|~~OT~~<br>~~Fo~~<br>~~anin i~~||||||
|Connection sockets 7/8"<br>~~Fo~~<br>~~anin i~~||||||
|~~Fo~~|Power supply socket<br>~~Fo~~|5-pin<br>~~—7~~<br>~~an~~||**543107**<br>~~LC~~<br>~~in i~~|**NECU-G78G5-C2**<br>~~LC~~<br>~~i~~|
|||4-pin<br>~~—7~~<br>~~an~~||**543108**<br>~~LC~~<br>~~in i~~|**NECU-G78G4-C2**<br>~~LC~~<br>~~i~~|
|~~Fo~~<br>~~a~~|Angled socket, 5-pin – open cable end, 5-wire<br>~~Fo~~<br>~~a~~|2 m<br>~~—7 ~~<br>~~an ~~||**573855**<br> ~~LC~~<br> ~~in i~~|**NEBU-G78W5-K-2-N-LE5**<br>~~LC~~<br>~~i~~|
|~~OT~~<br>~~a~~||||||
|M18 connection sockets<br>~~OT~~<br>~~a~~||||||
|~~a~~<br>~~oo~~<br>_—<br>5|Straight socket, screw terminal<br>~~a~~<br>~~oo~~<br>_—|4-pin<br>~~oo~~<br>~~-~~|PG9<br>~~oo~~|**18493**<br>~~oo~~|**NTSD-GD-9**<br>~~oo~~|
||||PG13.5<br>~~a~~<br>~~oo~~|**18526**<br>~~oo~~|**NTSD-GD-13.5**<br>~~oo~~|
|~~a~~<br>~~oo~~<br>_—<br>5<br>~~-)~~|Angled socket, screw terminal<br>~~a~~<br>~~oo~~<br>_—|4-pin<br>~~oo~~<br>~~-~~|PG9<br>~~a~~<br>~~oo~~|**18527**<br>~~oo~~|**NTSD-WD-9**<br>~~oo~~|
||Angled socket, screw terminal<br>~~oo~~<br>_—<br>~~-)~~|4-pin<br>~~oo~~<br>~~-~~<br>~~|~~|PG11<br>~~oo~~<br>~~|~)~~|**533119**<br>~~oo~~<br>~~~)~~|**NTSD-WD-11**<br>~~oo~~<br>~~~)~~|
|~~|~~<br>~~-)~~<br>~~|~)~~||||||
|Power supplysockets M12<br>~~-)~~<br>~~|~)~~||||||
|~~-)~~<br>sd<br>~~SY~~|Straight socket, screw terminal<br>~~es~~<br>~~-)~~<br>~~|~~<br>~~oo~~||5-pin<br>~~|~)~~<br>~~a~~|**8166793**<br>~~ee~~<br>~~~)~~|**NECL-L12G5-C2-Q10**<br>~~ee~~<br>~~~)~~|
|~~-)~~<br>~~SY~~<br>~~nn~~|Angled socket, screw terminal<br>~~-)~~<br>~~|~~<br>~~oo~~<br>~~nn~~||5-pin<br>~~| ~)~~<br>~~a~~<br>~~nn~~|**8166794**<br>~~~)~~<br>~~nn~~|**NECL-L12W5-C2-Q10**<br>~~~)~~<br>~~nn~~|
|~~oo~~<br>~~SY~~<br>~~a~~<br>~~OT~~<br>~~nnnn~~<br>~~nn~~||||||
|ullpower supplysocket<br>~~nnnn~~<br>~~nn~~||||||
|~~nn~~<br>KS|Socket, spring-loaded terminal,<br>plug pattern PP, fulfils requirements to AIDA<br>~~nn ~~|5-pin<br> ~~nn~~||**5195383**<br>~~nn~~|**NECU-M-PPG5PP-C1-PN**<br>~~nn~~|
2023/10 – Subject to change
219
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Interlinking block with system supply
|**Ordering data**<br>Designation||Part no.<br>Type|Part no.<br>Type|Part no.<br>Type|
|---|---|---|---|---|
|Mountingaccessories|||||
||Screws for mounting the bus node/connection block on the<br>plastic interlinkingblock|Bus node/metal connection block|**550218**|**CPX-DPT-30X32-S-4X**|
||Screws for mounting the bus node/connection block on the|Bus node/plastic connection block|**550219**|**CPX-M-M3x22-4x**|
||metal interlinking block|Bus node/metal connection block|**550216**|**CPX-M-M3x22-S-4x**|
||||||
Subject to change – 2023/10
220
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Interlinking block without power supply
## **Function**
Interlinking blocks ensure the electrical supply of all other CPX modules. They have contact rails, from which the other CPX components on the interlinking modules are supplied with power. Internal division of the power supply makes it possible to switch off specific areas of the sensors and actuators individually.
## **Area of application**
- All voltages are fed through to the next module by means of the interlinking blocks without supply.
- The connected electronics module for inputs/outputs or bus node taps off the required voltage.
## **General technical data**
|**General technical data**|**General technical data**|||||||||
|---|---|---|---|---|---|---|---|---|---|
|Type||||||CPX-GE-EV|||CPX-M-GE-EV|
|||||||||||
|Electrical connection||||||–|||–|
|Nominal operatingvoltage|||||[V DC]|24|||24|
|Acceptable current load (per contact/contact rail)|||er contact/contact rail)||[A]|16|||16|
|Degree ofprotection to EN 60529||||||Dependingon connection block||||
|Ambient temperature|||||[°C]|–5 ... +50||||
|Note on materials||||||RoHS-compliant||||
|Materials||||||PA-reinforced|||Aluminium|
|PWIS conformity||||||VDMA24364-B2-L||||
|Grid dimension|||||[mm]|50||||
|Dimensions W x L x H|||||[mm]|50 x 107 x 35||||
|Product weight|||||[g]|108|||169|
|||||||||||
|**Pin allocation**||||||||||
|Circuitry|||||||Pin|Allocation||
||||||||–|–||
||||||||–|–||
|||2AV Vatves|||||–<br>–<br>~~a~~|–<br>–||
2023/10 – Subject to change
221
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Interlinking block without power supply
## **Ordering data**
**==> picture [524 x 143] intentionally omitted <==**
**----- Start of picture text -----**<br>
Designation Part no. Type<br>Interlinking block without power supply<br>Plastic interlinking block 195742 CPX-GE-EV<br>Metal interlinking block 550206 CPX-M-GE-EV<br>Mounting accessories<br>Screws for mounting the bus node/connection block on the Bus node/metal connection block 550218 CPX-DPT-30X32-S-4X<br>plastic interlinking block<br>Screws for mounting the bus node/connection block on the Bus node/plastic connection block 550219 CPX-M-M3x22-4x<br>metal interlinking block Bus node/metal connection block 550216 CPX-M-M3x22-S-4x<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
222
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Interlinking block with additional supply for outputs
## **Function**
## **Area of application**
Interlinking blocks ensure the electri• 24 V DC supply voltage for outputs cal supply of all other CPX modules. They have contact rails, from which the other CPX components on the interlinking modules are supplied with power. Internal division of the power supply makes it possible to switch off specific areas of the sensors and actuators individually.
## **General technical data**
Nominal operating voltage [V DC] 24 Degree of protection to EN 60529 Depending on connection block Ambient temperature [°C] –5 ... +50 Note on materials RoHS-compliant PWIS conformity VDMA24364-B2-L Grid dimension [mm] 50 Dimensions W x L x H [mm] 50 x 107 x 35 **Technical data – Plastic interlinking blocks** Type CPX-GE-EV-Z -VL -7/8-4POL -7/8-5POL -7/8-5POL-VL Electrical connection M18 M18 7/8", 4-pin 7/8", 5-pin 7/8", 5-pin Power supply Outputs [A] Max. 16 Max. 8 Max. 10 Max. 8 Max. 8 Materials PA-reinforced Product weight [g] 125 ~~——= =~~ **Technical data – Metal interlinking blocks** Type CPX-M-GE-EV-Z -7/8-5POL -7/8-5POL-VL -PP-5POL Electrical connection 7/8", 5-pin 7/8", 5-pin AIDA push-pull, 5-pin Power supply Outputs [A] Max. 8 Max. 8 Max. 16 Materials Die-cast aluminium Product weight [g] 187 187 279 ~~——~~ 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 223
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Interlinking block with additional supply for outputs
**==> picture [524 x 559] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pin allocation – Plastic interlinking blocks<br>Circuitry Pin Allocation<br>Round plug, 4-pin<br>M18<br>1 n.c.<br>2 24 V DC load voltage supply for outputs<br>3 0 V<br>4 FE<br>7/8"<br>A n.c.<br>B 24 V DC load voltage supply for outputs<br>C FE<br>D 0V<br>Round plug, 5-pin<br>7/8"<br>1 0 V outputs<br>2 n.c.<br>3 FE<br>4 n.c.<br>5 24 V DC load voltage supply for outputs<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
224
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Interlinking block with additional supply for outputs
**==> picture [523 x 516] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pin allocation – Metal interlinking blocks<br>Circuitry Pin Allocation<br>Round plug, 5-pin<br>7/8"<br>1 0 V outputs<br>2 n.c.<br>3 FE<br>4 n.c.<br>5 24 V DC load voltage supply for outputs<br>5-pin push-pull plug<br>Plug pattern to PROFINET specification<br>1 n.c.<br>2 n.c.<br>3 24 V DC load voltage supply for outputs<br>4 0 V outputs<br>5 FE<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
225
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Interlinking block with additional supply for outputs
## **Ordering data**
|Data sheet – Interlinking block with additional supply for outputs|Data sheet – Interlinking block with additional supply for outputs|Data sheet – Interlinking block with additional supply for outputs|Data sheet – Interlinking block with additional supply for outputs|Data sheet – Interlinking block with additional supply for outputs|Data sheet – Interlinking block with additional supply for outputs|
|---|---|---|---|---|---|
|**Ordering data**<br>Designation<br>Part no.<br>Type<br>Interlinkingblock with additional supplyfor outputs<br>~~ae~~||||||
|~~a~~|M18 connection, plastic interlinking block<br>~~a~~|4-pin<br>~~ae~~|–<br>~~e~~|**195744**<br>~~e~~|**CPX-GE-EV-Z**<br>~~e~~|
||M18 connection, plastic interlinking block<br>~~a~~|4-pin<br>~~ae~~|For ATEX environment<br>~~e~~|**8022166**<br>~~e~~|**CPX-GE-EV-Z-VL**<br>~~e~~|
||7/8" connection, plastic interlinking block|4-pin<br>~~a~~|–|**541250**|**CPX-GE-EV-Z-7/8-4POL**|
|||5-pin|–|**541246**|**CPX-GE-EV-Z-7/8-5POL**|
|||5-pin|For ATEX environment|**8022173**|**CPX-GE-EV-Z-7/8-5POL-VL**|
||7/8" connection, metal interlinking block|5-pin|–|**550210**|**CPX-M-GE-EV-Z-7/8-5POL**|
|||5-pin|For ATEX environment|**8022158**|**CPX-M-GE-EV-Z-7/8-5POL-VL**|
|~~pf~~|Push-pull plug connection (AIDA), metal interlinking block<br>~~pf~~|5-pin|–|**563058**|**CPX-M-GE-EV-Z-PP-5POL**|
|~~pf~~<br>~~SS~~||||||
|Connection sockets 7/8"<br>~~pf~~<br>~~SSxa~~||||||
|~~SSxa~~<br>»|Power supply socket<br>~~SSxa~~|5-pin<br>~~xa~~||**543107**<br>~~xa~~|**NECU-G78G5-C2**<br>~~xa~~|
|||4-pin<br>~~xa~~||**543108**<br>~~xa~~|**NECU-G78G4-C2**<br>~~xa~~|
|ZO|Angled socket, 5-pin – open cable end, 5-wire|2 m||**573855**|**NEBU-G78W5-K-2-N-LE5**|
|~~oo~~||||||
|M18 connection sockets<br>~~—_—~~<br>~~oo~~<br>~~Sd~~||||||
|~~|~~|Straight socket, screw terminal<br>||4-pin|PG9<br>~~—~~|**18493**<br>~~a~~|**NTSD-GD-9**<br>~~a~~<br>~~—_—~~|
||||PG13.5|**18526**|**NTSD-GD-13.5**<br>~~—_—~~|
|&|Angled socket, screw terminal<br>~~rr~~<br>|4-pin<br>~~rr~~|PG9<br>~~rr~~|**18527**<br>~~rr~~|**NTSD-WD-9**<br>~~—_—~~<br>~~rr~~|
||Angled socket, screw terminal<br>~~rr~~<br> ~~a~~|4-pin<br>~~rr~~|PG11<br>~~rr~~|**533119**<br>~~rr~~|**NTSD-WD-11**<br>~~rr~~|
|~~Ql.~~<br>~~|~~<br>~~DD)”~~||||||
|ullpower supplysocket<br>~~Ql.~~<br>~~|~~<br>~~DD)”~~<br>~~&) ee~~<br>~~rT...~~||||||
|~~Ql.~~<br>~~&) ee~~|Socket, spring-loaded terminal,<br>plug pattern PP, fulfils requirements to AIDA<br>~~Ql.~~<br>~~|~~<br>~~ee~~|5-pin<br>~~|~~<br>~~DD)”~~<br>~~rT...~~||**5195383**<br>~~DD)”~~<br>~~rT...~~|**NECU-M-PPG5PP-C1-PN**<br>~~DD)”~~<br>~~rT...~~|
|~~Ql.~~<br>~~|~~<br>~~DD)”~~<br>~~&) ee~~<br>~~rT...~~<br>~~|~~<br>~~OO~~||||||
|gaccessories<br>~~&) ee~~<br>~~rT...~~<br>~~OO~~<br>COCF~~|~~<br>~~a~~||||||
|~~&) ee~~<br>~~OO~~<br>COCF ~~|~~|Screws for mounting the bus node/connection block on the plas-<br>tic interlinkingblock<br>~~ee~~<br>~~|~~|Bus node/metal connection block<br>~~rT...~~||**550218**<br>~~rT...~~<br>~~ee~~|**CPX-DPT-30X32-S-4X**<br>~~rT...~~<br>~~a~~|
||Screws for mounting the bus node/connection block on the met-<br>al interlinking block<br>~~ee~~<br>~~|~~<br>~~ee~~|Bus node/plastic connection block<br>~~rT...~~<br>~~$i~~<br>~~ee~~||**550219**<br>~~rT...~~<br>~~$i~~<br>~~ee~~<br>~~ee~~|**CPX-M-M3x22-4x**<br>~~rT...~~<br>~~a~~<br>~~$i~~|
|||Bus node/metal connection block<br>~~$i~~<br>~~ee~~||**550216**<br>~~$i~~<br>~~ee~~<br>~~ee~~|**CPX-M-M3x22-S-4x**<br>~~$i~~|
Subject to change – 2023/10
226
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Interlinking block with additional supply for valves
## **Function**
## **Area of application**
Interlinking blocks ensure the electri• 24 V DC supply voltage for valves cal supply of all other CPX modules. They have contact rails, from which the other CPX components on the interlinking modules are supplied with power. Internal division of the power supply makes it possible to switch off specific areas of the sensors and actuators individually.
## **General technical data**
|ing modules are supplied with power.<br>Internal division of the power supply<br>makes it possible to switch off specific<br>areas of the sensors and actuators in-<br>dividually.|ing modules are supplied with power.<br>Internal division of the power supply<br>makes it possible to switch off specific<br>areas of the sensors and actuators in-<br>dividually.|ing modules are supplied with power.<br>Internal division of the power supply<br>makes it possible to switch off specific<br>areas of the sensors and actuators in-<br>dividually.|ing modules are supplied with power.<br>Internal division of the power supply<br>makes it possible to switch off specific<br>areas of the sensors and actuators in-<br>dividually.|
|---|---|---|---|
|**General technical data**<br>Type<br>CPX-GE-EV-V<br>CPX-GE-EV-V-VL<br>CPX-GE-EV-V-7/8-4POL<br>Electrical connection<br>M18<br>7/8", 4-pin||||
|Nominal operatingvoltage<br>[V DC]|24|||
|Acceptable current load (per contact/contact rail)<br>[A]|16|8|10|
|Degree ofprotection to EN 60529|Dependingon connection block|||
|Ambient temperature<br>[°C]|–5 ... +50|||
|Note on materials|RoHS-compliant|||
|Materials|PA-reinforced|||
|PWIS conformity|VDMA24364-B2-L|||
|Grid dimension<br>[mm]|50|||
|Dimensions W x L x H<br>[mm]|50 x 107 x 35|||
|Product weight<br>[g]|125|||
## **Pin allocation – Plastic interlinking blocks**
**==> picture [519 x 179] intentionally omitted <==**
**----- Start of picture text -----**<br>
Circuitry Pin Allocation<br>Round plug, 4-pin<br>M18<br>1 n.c.<br>OWvawes 15 3 a<br>2 24 V DC load voltage supply for valves<br>3 0 V<br>4 FE<br>TY OV output O 0 - a<br>el eeNT 7/8"<br>TTP]1 24Veujse. |B C a AB n.c.24 V DC load voltage supply for valves<br>C FE<br>ie: -T> eSa D 0V<br>ar) ea c©eeGY ee<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
227
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Interlinking block with additional supply for valves
## **Ordering data**
|Data sheet – Interlinking block with additional supply for valves|Data sheet – Interlinking block with additional supply for valves|Data sheet – Interlinking block with additional supply for valves|Data sheet – Interlinking block with additional supply for valves|Data sheet – Interlinking block with additional supply for valves|Data sheet – Interlinking block with additional supply for valves|
|---|---|---|---|---|---|
|**Ordering data**<br>Designation<br>Part no.<br>Type<br>Interlinkingblock with additional supplyfor valves<br>~~Ce~~||||||
|~~C~~|M18 connection, plastic interlinking block<br>~~C~~|4-pin<br>~~Ce~~|–<br>~~e~~|**533577**<br>~~e~~|**CPX-GE-EV-V**<br>~~e~~|
||||For ATEX environment|**8022171**|**CPX-GE-EV-V-VL**|
|~~y~~|7/8" connection, plastic interlinking block|4-pin|–|**541252**<br>~~EE~~|**CPX-GE-EV-V-7/8-4POL**<br>~~EE~~<br>~~EE~~|
|~~EE~~<br>~~EE~~<br>~~EE~~||||||
|Connection sockets 7/8"<br>~~EE~~<br>~~EE~~<br>~~ee~~<br>S\||||||
|S\<br>sy|Power supply socket|5-pin<br>~~LL~~||**543107**<br>~~LL~~|**NECU-G78G5-C2**<br>~~LL~~|
|||4-pin<br>~~LL~~||**543108**<br>~~LL~~|**NECU-G78G4-C2**<br>~~LL~~|
|ZA.<br>|Angled socket, 5-pin – open cable end, 5-wire<br>|2 m<br><br>~~EE~~||**573855**<br><br>~~EEEE~~|**NEBU-G78W5-K-2-N-LE5**<br><br>~~EEEEEE~~<br>~~EEEEEEEE~~|
|~~EEE~~<br>~~EE~~<br>~~EEEEEEEEEE~~<br>~~EEEEEEEE~~||||||
|M18 connection sockets<br>~~EEE~~<br>~~EE~~<br>~~EE EE EEE EEE~~<br>~~EEE EEE EE~~<br>~~Ce~~<br>~~SC.~~||||||
|~~Ce~~<br>~~SC.~~<br>~~©~~|Straight socket, screw terminal<br>~~Ce~~<br>~~.~~<br>~~GD~~|4-pin<br>~~Ce~~|PG9<br>~~Ce~~|**18493**<br>~~Ce~~|**NTSD-GD-9**<br>~~Ce~~|
|||4-pin<br>~~GD~~|PG13.5<br>~~GD~~|**18526**|**NTSD-GD-13.5**|
|~~SC.~~<br>~~© ~~|Angled socket, screw terminal<br>~~.~~<br>~~GD~~|4-pin<br>~~GD~~|PG9<br>~~GD~~|**18527**|**NTSD-WD-9**|
||Angled socket, screw terminal<br> ~~GD~~<br>~~EE~~<br>~~EEEEEE~~|4-pin<br>~~GD~~<br>~~EE~~<br>~~EE~~<br>~~EEE~~|PG11<br>~~GD~~<br>~~EE~~<br>~~EEE EE~~<br>~~EEEEEEEE~~|**533119**<br>~~EE~~<br>~~EEEEEE~~<br>~~EEE~~|**NTSD-WD-11**<br>~~EE~~<br>~~EOE~~<br>~~EEE EE~~|
|~~EE~~<br>~~EEE~~<br>~~EEEEEE~~<br>~~EEE~~<br>~~EEE EE~~<br>~~EEEEEEEEEEEEEE~~<br>~~EEEEOE~~<br>~~EEE EE~~||||||
|gaccessories<br>~~EEE~~<br>~~EE EE EE~~<br>~~EEE~~<br>~~EEE EE~~<br>~~EE EE EE EE EEE EEE~~<br>~~EEE EOE~~<br>~~EEE EE~~<br>~~ee~~<br>es||||||
|~~a~~|Screws for mounting the bus node/connection block on the plas-<br>tic interlinking block<br>~~a~~|Bus node/metal connection block<br>~~a~~||**550218**<br>~~a~~<br>es|**CPX-DPT-30X32-S-4X**<br>~~a~~|
Subject to change – 2023/10
228
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Interlinking block with system forwarding
## **Function**
## **Area of application**
Interlinking blocks ensure the electri• Forwarding of 24 V DC supply voltcal supply of all other CPX modules. age for the electronics of the CPX They have contact rails, from which the terminal other CPX components on the interlink• Forwarding of 24 V DC supply volting modules are supplied with power. age for inputs Internal division of the power supply • Forwarding of 24 V DC supply voltmakes it possible to switch off specific age for valves areas of the sensors and actuators in• Forwarding of 24 V DC supply voltdividually. age for outputs
## **General technical data**
|**General technical data**||
|---|---|
|Nominal operatingvoltage<br>[V DC]|24|
|Degree ofprotection to EN 60529|Dependingon connection block|
|Ambient temperature<br>[°C]|–5 ... +50|
|Note on materials|RoHS-compliant|
|PWIS conformity|VDMA24364-B2-L|
|Grid dimension<br>[mm]|50|
|Dimensions W x L x H<br>[mm]|50 x 107 x 35|
## **Technical data – Metal interlinking blocks**
|**Technical data – Metal interlinking blocks**||||
|---|---|---|---|
|Type|||CPX-M-GE-EV-W-M12-5POL|
|||||
|Electrical connection|||Socket|
||||M12x1|
||||5-pin|
||||L-coded|
|Power supply|Sensors and electronics|[A]|Max. 16|
||Valves and outputs|[A]|Max. 16|
|Corrosion resistance class CRC1)|||0|
|Type of mounting|||Angled fitting|
|Materials|||Die-cast aluminium|
|Certification|||c UL - Recognized (OL)|
|Product weight||[g]|266|
1) Additional information: www.festo.com/x/topic/kbk
- **Note** H- Points to note about the interlinking • Must be mounted as the first • Only one interlinking block block CPX-M-GE-EV-W-M12-5POL: module to the right or to the left of permitted per CPX terminal the system supply
2023/10 – Subject to change
229
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Interlinking block with system forwarding
||**Pin allocation – Metal interlinking blocks**|**Pin allocation – Metal interlinking blocks**|**Pin allocation – Metal interlinking blocks**|**Pin allocation – Metal interlinking blocks**|**Pin allocation – Metal interlinking blocks**||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||Circuitry||||||||||||Pin|Allocation|
||||||||||||||||
|**Roundplug, 5-pin**<br>**M12**<br>~~|~~<br>~~OO~~|||||||||||||||
||||||||||||||1|24 V DC power supply for electronics and sensors|
||||||24Vvaives||||4||1||2<br>0 V valves and outputs<br>3<br>0 V electronics and sensors<br>4<br>24 V DC load voltage supply for valves and outputs<br>~~a~~<br>~~-~~||
||||||||||||||FE|FE|
|**Ordering data**<br>Designation<br>Part no.<br>Type<br>Interlinkingblock with system forwarding<br>~~|~~|**Ordering data**<br>Designation<br>Part no.<br>Type<br>Interlinkingblock with system forwarding<br>~~|~~|**Ordering data**<br>Designation<br>Part no.<br>Type<br>Interlinkingblock with system forwarding<br>~~|~~|**Ordering data**<br>Designation<br>Part no.<br>Type<br>Interlinkingblock with system forwarding<br>~~|~~|**Ordering data**<br>Designation<br>Part no.<br>Type<br>Interlinkingblock with system forwarding<br>~~|~~|
|---|---|---|---|---|
|Spooe Kee|M12x1 L-coded connection, metal interlinking block|5-pin<br>~~EE~~|**8098391**<br>~~EE~~<br>~~EE~~|**CPX-M-GE-EV-W-M12-5POL**<br>~~EEEEEEEEE EET~~|
|~~EE~~<br>~~EEEE~~<br>~~EE~~<br>~~EEEEEEEEE EET~~|||||
|Power supply plugs M12<br>~~EE~~<br>~~EE EE~~<br>~~EE~~<br>~~EE EE EE EEE EET~~<br>~~|~~<br>~~xs|~~<br>~~ft~~<br>~~**|**~~|||||
|~~|~~<br>~~xs|~~|Straight plug, screw terminal<br>~~|~~<br>~~|~~<br>~~ft~~|5-pin<br>~~|~~<br>~~ft~~<br>~~**|**~~|**8166791**<br>~~|~~|**NECL-S-L12G5-C2-Q10**<br>~~|~~|
|~~xs |~~|Angled plug, screw terminal<br>~~|~~<br>~~ft~~|5-pin<br>~~ft~~<br>~~**|**~~|**8166792**|**NECL-S-L12W5-C2-Q10**|
Subject to change – 2023/10
230
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Pneumatic interface for valve terminal MPA-S
## **Function**
The pneumatic interface VMPA-FB establishes the electromechanical connection between the CPX terminal and the valve terminal MPA-S. The signals from the bus node are forwarded to the control electronics in the electrical modules of the valve terminal MPA-S via the integrated CPX bus. The bus signal for activating the solenoid coils is converted in the electronics module for max. 8 coils.
From a technical point of view, the individual MPA pneumatic modules each represent a separate electrical module with digital outputs. Valves, which are galvanically isolated, can be supplied with power via the interlinking block CPX-GE-EV-V.
## **Area of application**
- Interface to the valve terminal MPA-S
- Max. 128 solenoid coils
- Characteristics of the electronics module of the valve terminal MPA-S can be parameterised; for example, status of the solenoid coils in the event of fieldbus communication being interrupted (fail-safe), individual channel diagnostics can be activated, condition monitoring can be activated individually for each valve
- The pneumatic interface receives the voltage for the electronics and the supply voltage for the valves
from the left-hand interlinking block and feeds them through to the electronics modules of the valve terminal MPA-S
- Electronics modules of the valve terminal MPA-S:
- Undervoltage of valves
- Short circuit of valves
- Open load of valves
- Counter preset reached in condition monitoring
||**General technical data**||||||
|---|---|---|---|---|---|---|
||Type||||VMPA-FB-EPL-G|VMPA-FB-EPL-E|
||||||||
||Valve terminal design||||Modular, valve sizes can be mixed||
||Maximum number of valvepositions||||64||
||Maximum number ofpressure zones||||17||
||Signal status indication||||LED||
||Pilot air supply||||Internal|External|
||Operating pressure|||[MPa]|0.3 ... 0.8|–0.09 ... 1|
|||||[bar]|3 ... 8|–0.9 ... 10|
||Pilot pressure|||[MPa]|0.3 ... 0.8|0.3 ... 0.8|
|||||[bar]|3 ... 8|3 ... 8|
||Product weight|||[g]|320||
||Degree of protection||||IP67||
||||||||
|**Technical data – Electrics**<br>Nominal operatingvoltage<br>[V DC]<br>24<br>Permissible voltage fluctuations<br>[%]<br>±25<br>~~—————~~|||||||
|**Materials**<br>Note on materials<br>RoHS-compliant<br>LABS (PWIS) conformity<br>VDMA24364-B1/B2-L<br>~~—————~~|||||||
2023/10 – Subject to change
231
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Accessories – Pneumatic interface for valve terminal MPA-S
## **Operating and environmental conditions**
|Accessories – Pneumatic interface for valve terminal MPA-S|Accessories – Pneumatic interface for valve terminal MPA-S|
|---|---|
|**Operating and environmental conditions**<br>Operatingmedium<br>Compressed air to ISO 8573-1:2010 [7:4:4]||
|Note on the operating/pilot medium<br>Lubricated o|Lubricated operationpossible (in which case lubricated operation will always be required)|
|Ambient temperature<br>[°C]<br>–5 ... +50|–5 ... +50|
|Temperature of medium<br>[°C]<br>–5 ... +50|–5 ... +50|
|Storage temperature<br>[°C]<br>–20 ... +40|–20 ... +40|
|Relative humidity<br>Max. 90% at 40°C|Max. 90% at 40°C|
|Corrosion resistance class CRC1)<br>1||
|CE marking (see declaration of conformity)<br>To EU EMC Directive<br>To EU RoHS Directive<br>To EU Explosion Protection Directive (ATEX)|To EU EMC Directive2)|
||To EU RoHS Directive|
||To EU Explosion Protection Directive (ATEX)|
|UKCA marking (see declaration of conformity)<br>To UK EMC regulations<br>To UK RoHS regulations<br>To UK regulations for explosions|To UK EMC regulations|
||To UK RoHS regulations|
||To UK regulations for explosions|
|KC marking<br>KC EMC|KC EMC|
|Certification<br>RCM com<br>c UL us - Reco|RCM compliance mark|
||c UL us - Recognized (OL)|
|Certificate-issuing authority<br>DNV 15.0193 X|DNV 15.0193 X|
- 1) More information www.festo.com/x/topic/crc
- 2) For information about the area of use, see the EC declaration of conformity at: www.festo.com/catalogue/... d Support/Downloads. If the devices are subject to usage restrictions in residential, commercial or light-industrial environments, further measures for the reduction of the emitted interference may be necessary.
## **ATEX**
|**ATEX**||
|---|---|
|ATEX categoryforgas|II 3G|
|Type of (ignition)protection forgas|Ex ec IIC T4 Gc X|
|Explosion ambient temperature<br>[°C]|–5 ≤ Ta ≤ +50|
|Explosion protection certification outside the EU|EPL Db (GB)|
||EPL Gb (GB)|
## **Overview – Pneumatic interface VMPA-FB**
**==> picture [240 x 217] intentionally omitted <==**
**----- Start of picture text -----**<br>
4<br>3<br>2<br>1 s egg<br>a wQa<br>5<br>**----- End of picture text -----**<br>
- [1] Pneumatic interface VMPA-FB
- [2] Inscription label
- [3] Flat plate silencer
- [4] Exhaust plate for ducted exhaust air
[5] Fittings
Subject to change – 2023/10
232
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Accessories – Pneumatic interface for valve terminal MPA-S
**==> picture [523 x 272] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data<br>Designation Part no. Type<br>Pneumatic interface for CPX plastic interlinking module<br>Ducted exhaust air, internal pilot air 533370 VMPA-FB-EPL-G<br>Ducted exhaust air, external pilot air 533369 VMPA-FB-EPL-E<br>Flat plate silencer, internal pilot air 533372 VMPA-FB-EPL-GU<br>Flat plate silencer, external pilot air 533371 VMPA-FB-EPL-EU<br>Pneumatic interface for CPX metal interlinking module<br>Ducted exhaust air, internal pilot air 552286 VMPA-FB-EPLM-G<br>Ducted exhaust air, external pilot air 552285 VMPA-FB-EPLM-E<br>Flat plate silencer, internal pilot air 552288 VMPA-FB-EPLM-GU<br>Flat plate silencer, external pilot air 552287 VMPA-FB-EPLM-EU<br>Exhaust plate<br>For ducted exhaust air, with 10 mm push-in connector 533375 VMPA-AP<br>For ducted exhaust air, with QS-3/8 connector 541629 VMPA-AP-3/8<br>Flat plate silencer 533374 VMPA-APU<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
233
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Pneumatic interface for valve terminal MPA-L
## **Area of application**
## **Function**
The pneumatic interface VMPAL establishes the electromechanical connection between the terminal CPX and the valve terminal MPA-L.
- Actuation of the valve terminal MPA-L
- Max. 32 solenoid coils
valve terminal MPA-L. • The pneumatic interface receives The bus signal for actuating the solethe voltage for the electronics and noid coils is converted in the pneumatthe supply voltage for the valves ic interface for the entire valve termifrom the left-hand interlinking block nal. and feeds them through to the elecThe interlinking within the valve termitrical modules of the valve terminal MPA-L
The interlinking within the valve terminal is identical with the interlinking with multi-pin plug connections.
## **General technical data**
|**General technical data**||||
|---|---|---|---|
|Type|||VMPAL-EPL-CPX|
|||||
|Number of solenoid coils|||32|
|Operating pressure||[bar]|–0.9 ... 10|
|Pilotpressure||[bar]|3 ... 8|
|Nominal operatingvoltage||[V DC]|24|
|Degree ofprotection to EN 60529|||IP67|
|Ambient temperature||[°C]|–5 ... +50|
|Note on materials|||RoHS-compliant|
|PWIS conformity|||VDMA24364-B1/B2-L|
Subject to change – 2023/10
234
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Pneumatic interface for valve terminal MPA-L
## **Overview – Pneumatic interface VMPAL**
**==> picture [522 x 276] intentionally omitted <==**
**----- Start of picture text -----**<br>
5<br>[1] Valve terminal MPA-L [3] Terminal CPX [4] Inscription label [5] Mounting for H-rail<br>[2] Pneumatic interface VMPAL<br>Ordering data<br>Designation Part no. Type<br>S Pneumatic interface for CPX plastic interlinking module T 570783 VMPAL-EPL-CPX<br>2023/10 – Subject to change d Internet: www.festo.com/catalogue/... 235<br>**----- End of picture text -----**<br>
235
Terminal CPX
## Data sheet – Pneumatic interface for valve terminal VTSA/VTSA-F
## **Function**
## **Area of application**
The pneumatic interface VTSA provides • Interface to the valve terminal VTSA the electromechanical connection beand VTSA-F tween the terminal CPX and valve ter• Max. 32 solenoid coils minal VTSA/VTSA-F. • Address space allocation (configuraA complete pneumatic control loop tion) of valve terminals can be set system (FB-valve-drive-sensor-FB) can using integrated DIL switches therefore be connected to the fieldbus • Properties of the pneumatic interusing the input modules of the CPX terface can be parameterised, e.g. staminal. tus of the solenoid coil in the event Different circuits for valves and electriof fieldbus communication being incal outputs are implemented using an terrupted (fail-safe) additional supply. The integrated valve • The pneumatic interface receives diagnostics enable the causes of errors the voltage for the electronics and to be found quickly, increasing system the supply voltage for the valves availability. from the left-hand interlinking block
• Detection of missing solenoid coils and short circuit monitoring for the valves
## **General technical data**
|to be found quickly, increasing system<br>availability.<br>the supply voltage for the valves<br>from the left-hand interlinking block<br>• Detection of missing solenoid coils<br>and short circuit monitoring for the<br>valves|to be found quickly, increasing system<br>availability.<br>the supply voltage for the valves<br>from the left-hand interlinking block<br>• Detection of missing solenoid coils<br>and short circuit monitoring for the<br>valves|
|---|---|
|**General technical data**<br>Max. no. of valve positions<br>16 with double solenoid valves<br>32 with single solenoid valves||
||32 with single solenoid valves|
|Valve terminal interface|Type 44, VTSA|
|Electrical control|Fieldbus|
|Electrical connection|Via CPX|
|Diagnostics|Undervoltage of valves|
|Parameterisation|Failsafeper channel|
||Forcing per channel|
||Idle modeper channel|
||Module monitoring|
|LED displays|1groupdiagnostics|
||Channel status on valves|
|Fuseprotection (short circuit)|Internal electronic fuseper valve output|
|Galvanic isolation channel – internal bus|Yes, when usingan additional supplyfor the valves|
|Nominal operatingvoltage<br>[V DC]|24|
|Operatingvoltage range<br>[V DC]|21.6 ... 26.4|
|Intrinsic current consumption at nominal<br>operating voltage<br>Electronics<br>[mA]<br>Valves<br>[mA]|Typically15|
||Typically50|
|Max.power supply per channel<br>[A]|0.2|
|Max. residual currentper module<br>[A]|4|
|Degree of protection|IP65|
||NEMA 4|
|Product weight<br>[g]|590|
Subject to change – 2023/10
236
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
Data sheet – Pneumatic interface for valve terminal VTSA/VTSA-F
**==> picture [523 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
Materials<br>Housing Die-cast aluminium<br>Cover PA<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B1/B2-L<br>Operating and environmental conditions<br>Ambient temperature [°C] –5 ... +50<br>Corrosion resistance class CRC [1)] 0<br>**----- End of picture text -----**<br>
- 1) Additional information: www.festo.com/x/topic/kbk
|**Ordering data**<br>Designation<br>Part no.<br>Type<br>Forplastic interlinkingblock<br>**543416**<br>**VABA-S6-1-X1**<br>For metal interlinking block<br>Diagnostics via feldbus<br>**550663**<br>**VABA-S6-1-X2**|**Ordering data**<br>Designation<br>Part no.<br>Type<br>Forplastic interlinkingblock<br>**543416**<br>**VABA-S6-1-X1**<br>For metal interlinking block<br>Diagnostics via feldbus<br>**550663**<br>**VABA-S6-1-X2**|**Ordering data**<br>Designation<br>Part no.<br>Type<br>Forplastic interlinkingblock<br>**543416**<br>**VABA-S6-1-X1**<br>For metal interlinking block<br>Diagnostics via feldbus<br>**550663**<br>**VABA-S6-1-X2**|**Ordering data**<br>Designation<br>Part no.<br>Type<br>Forplastic interlinkingblock<br>**543416**<br>**VABA-S6-1-X1**<br>For metal interlinking block<br>Diagnostics via feldbus<br>**550663**<br>**VABA-S6-1-X2**|**Ordering data**<br>Designation<br>Part no.<br>Type<br>Forplastic interlinkingblock<br>**543416**<br>**VABA-S6-1-X1**<br>For metal interlinking block<br>Diagnostics via feldbus<br>**550663**<br>**VABA-S6-1-X2**|**Ordering data**<br>Designation<br>Part no.<br>Type<br>Forplastic interlinkingblock<br>**543416**<br>**VABA-S6-1-X1**<br>For metal interlinking block<br>Diagnostics via feldbus<br>**550663**<br>**VABA-S6-1-X2**|
|---|---|---|---|---|---|
|||For metal interlinking block|Diagnostics via feldbus|**550663**|**VABA-S6-1-X2**|
||||Diagnostics via process data image|**573613**|**VABA-S6-1-X2-D**|
|||||||
2023/10 – Subject to change
237
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Data sheet – Pneumatic interface for valve terminal VTSA-F-CB
## **Area of application**
## **Function**
The pneumatic interface provides the electromechanical connection between the terminal CPX and valve terminal VTSA-F-CB.
- Interface to valve terminal VTSA-F-CB
- Max. 24 solenoid coils
- Properties of the pneumatic interface can be parameterised, e.g. status of the solenoid coil in the event of fieldbus communication being interrupted (fail-safe)
A complete pneumatic control loop tus of the solenoid coil in the event system (FB-valve-drive-sensor-FB) can of fieldbus communication being intherefore be connected to the fieldbus terrupted (fail-safe) using the input modules of the CPX ter• The pneumatic interface receives minal. the voltage for the electronics and Different circuits for valves and electrithe supply voltage for the valves cal outputs are implemented using an from the left-hand interlinking block
Different circuits for valves and electrithe supply voltage for the valves cal outputs are implemented using an from the left-hand interlinking block additional supply. The integrated valve • The supply voltage for the valves is diagnostics enable the causes of errors provided from the left-hand interto be found quickly, increasing system linking block or externally availability. • Detection of missing solenoid coils and short circuit monitoring for the valves
## **General technical data**
|diagnostics enable the causes of errors<br>to be found quickly, increasing system<br>availability.<br>provided from the left-hand inter-<br>linking block or externally<br>• Detection of missing solenoid coils<br>and short circuit monitoring for the<br>valves|diagnostics enable the causes of errors<br>to be found quickly, increasing system<br>availability.<br>provided from the left-hand inter-<br>linking block or externally<br>• Detection of missing solenoid coils<br>and short circuit monitoring for the<br>valves|diagnostics enable the causes of errors<br>to be found quickly, increasing system<br>availability.<br>provided from the left-hand inter-<br>linking block or externally<br>• Detection of missing solenoid coils<br>and short circuit monitoring for the<br>valves|diagnostics enable the causes of errors<br>to be found quickly, increasing system<br>availability.<br>provided from the left-hand inter-<br>linking block or externally<br>• Detection of missing solenoid coils<br>and short circuit monitoring for the<br>valves|
|---|---|---|---|
|**General technical data**<br>Pneumatic interface<br>Without voltage zones<br>With safe voltage zones<br>With external power supply<br>to the valves<br>Max. no. of valve positions<br>12 with double solenoid valves<br>24 with single solenoid valves||||
||Without voltage zones<br>With safe voltage zones<br>With external power supply<br>to the valves<br>12 with double solenoid valves|||
||24 with single solenoid valves|||
|Valve terminal interface|Type 44, VTSA|||
|Electrical control|Fieldbus|||
|Electrical connection|Via CPX|||
|Electrical connection output<br>Function<br>Connection type<br>Connection technology<br>Number ofpins/wires|–|Safe digital output|–|
||–|Socket|–|
||–|M12x1, A-coded to<br>EN 61076-2-101|–|
||–|5|–|
|Electrical connection, power supply to<br>valves<br>Function<br>Connection type<br>Connection technology<br>Number ofpins/wires|–|–|–|
||–|–|Plug|
||–|–|3x M12x1, A-coded|
||–|–|5|
|Diagnostics|Wire breakper valve coil|||
||Short circuit of valves|||
||Undervoltage of valves|||
|Parameterisation|Failsafeper channel|||
||Forcing per channel|||
||Idle modeper channel|||
||Module monitoring|||
|LED displays|1groupdiagnostics|1groupdiagnostics|1groupdiagnostics|
||Channel status on valves|–|Channel status on valves|
||–|–|3 load supply|
Subject to change – 2023/10
238
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Pneumatic interface for valve terminal VTSA-F-CB
## **Technical data – Electrics**
**==> picture [523 x 554] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pneumatic interface<br>Without voltage zones With safe voltage zones With external power supply<br>to the valves<br>Nominal operating voltage [V DC] 24<br>Operating voltage range [V DC] 21.6 ... 26.4<br>Intrinsic current consumption at nominal Electronics [mA] Typically 11 • Typically 45 for electronics Typically 11<br>operating voltage without CPX-FVDA-P2<br>• Typically 110 for electron-<br>ics with CPX-FVDA-P2<br>Valves [mA] Typically 45 • Typically 25 for valves Typically 45<br>without CPX-FVDA-P2<br>• Typically 90 for valves<br>with CPX-FVDA-P2<br>Max. power supply per channel [A] 0.2 0.2 0.2<br>Max. residual current per module [A] 6 4.5 6<br>Fuse protection (short circuit) Internal electronic fuse per Internal electronic fuse per Internal electronic fuse per<br>valve output valve output valve output<br>Galvanic isolation channel – internal bus Yes, when using an addition- Yes, when using an addition- Yes<br>al supply for the valves al supply for the valves<br>Materials<br>Pneumatic interface<br>Without voltage zones With safe voltage zones With external power supply<br>to the valves<br>Housing Die-cast aluminium – Die-cast aluminium<br>Cover PA PA PA<br>Sub-base – Die-cast aluminium –<br>Seals – NBR –<br>Screws – Steel –<br>Note on materials RoHS-compliant RoHS-compliant RoHS-compliant<br>PWIS conformity VDMA24364-B1/B2-L VDMA24364-B1/B2-L VDMA24364-B1/B2-L<br>Operating and environmental conditions<br>Pneumatic interface<br>Without voltage zones With safe voltage zones With external power supply<br>to the valves<br>Ambient temperature [°C] –5 ... +50 –5 ... +50 –5 ... +50<br>Storage temperature [°C] – –20 ... +60 –<br>Corrosion resistance class CRC [1)] 0 0 0<br>Shock resistance – Shock test with severity lev- –<br>el 2 to FN 942017-5 and<br>EN 60068-2-27<br>Vibration resistance – Transport application test –<br>with severity level 2 to<br>FN 942017-4 and<br>EN 60068-2-6<br>CE marking (see declaration of conformity) [3)] – To EU EMC Directive [2)] –<br>– To EU RoHS Directive –<br>UKCA marking (see declaration of conformity) [3)] – To UK instructions for EMC –<br>– To UK RoHS instructions –<br>Degree of protection IP65 IP65 IP65<br>NEMA 4 – NEMA 4<br>**----- End of picture text -----**<br>
1) Additional information: www.festo.com/x/topic/kbk
2) For information about the area of use, see the EC declaration of conformity at: www.festo.com/catalogue/... d Support/Downloads. If the devices are subject to usage restrictions in residential, commercial or light-industrial environments, further measures for the reduction of the emitted interference may be necessary.
3) Additional information: www.festo.com/catalogue/... d Support/Downloads.
2023/10 – Subject to change
239
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet – Pneumatic interface for valve terminal VTSA-F-CB
**==> picture [524 x 455] intentionally omitted <==**
**----- Start of picture text -----**<br>
Combinations of bus nodes/control blocks with pneumatic interface<br>Bus node/control block Part no. Pneumatic interface<br>VABA-...-X1-CB VABA-...-X2-CB VABA-...-X2-F1-CB VABA-...-X2-F2-CB<br>CPX-FB13 195740 h h h h<br>CPX-FB36 1912451 h h – –<br>CPX-FB37 2735960 h h – –<br>CPX-FB43 8110369 h h h h<br>CPX-M-FB44 8110370 h h h h<br>Ordering data<br>Description Product weight Part no. Type<br>[g]<br>Pneumatic interface without voltage zones<br>For plastic interlinking block 560 8082877 VABA-S6-1-X1-CB<br>For metal interlinking block 560 8082876 VABA-S6-1-X2-CB<br>Pneumatic interface with voltage zones<br>For metal interlinking block Division of the connected valves into up to 3 safe 734 8068240 VABA-S6-1-X2-F1-CB<br>voltage zones<br>For metal interlinking block • Division of the connected valves into up to 2 754 8068241 VABA-S6-1-X2-F2-CB<br>safe voltage zones<br>• 1 external safe voltage zone<br>For plastic interlinking block • Division of the connected valves into up to 3 580 8082879 VABA-S6-1-X1-3V-CB<br>voltage zones<br>• External power supply for each voltage zone<br>For metal interlinking block • Division of the connected valves into up to 3 580 8082878 VABA-S6-1-X2-3V-CB<br>voltage zones<br>• External power supply for each voltage zone<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
240
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet
**==> picture [523 x 585] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions – Plastic interlinking module Download CAD data a www.festo.com<br>With bus nodes and connection blocks<br>[1] Left-hand end plate (earthing [5] Connection block [8] Right-hand end plate n Number of CPX modules<br>plate optional) CPX-AB-8-KL-4POL [9] Mounting clip for wall mounting<br>[2] Bus node [6] Connection block (required every 2 ... 3 connec-<br>[3] Connection block CPX-AB-1-SUB-BU-25POL tion blocks)<br>CPX-AB-4-M12-8POL [7] Connection block<br>[4] Connection block CPX-AB-4-M12-8POL<br>CPX-AB-8-M8-3POL<br>Type B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 D1<br>@<br>CPX-M 175 122.3 107.3 78 66.3 65 18.9 7.5 6.6 4.4 4.3<br>Type H1 H2 H3 H4 H5 H6<br>CPX-M 118 110 92 89.1 55.1 10.8<br>Type L1 [1)] L2 L3 [2)] L4 L5 [3)] L6 L7 L8 L9 L10 L11<br>CPX-M nx50.1 150.3 100.2 50.1 30.8 7.1 8.8 8.5 6.8 1.5 1<br>**----- End of picture text -----**<br>
- 1) n = Number of CPX modules
2023/10 – Subject to change
241
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet
**==> picture [523 x 595] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions – Metal interlinking block Download CAD data a www.festo.com<br>With bus nodes and connection blocks<br>[1] Left-hand end plate [5] Connection block [8] Right-hand end plate [10] Hole for self-tapping screw<br>[2] Bus node CPX-M-AB-4-M12X2-5POL [9] Mounting bracket for wall M2.5<br>[3] Connection block [6] Connection block mounting<br>CPX-M-AB-8-M12X2-5POL CPX-AB-1-SUB-BU-25POL<br>[4] Connection block [7] Connection block<br>CPX-M-AB-8-M12X2-5POL CPX-AB-4-M12-8POL<br>Type B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13<br>CPX-M 199 136 124.9 118.85 108.1 77.95 66.3 65 19.25 20 7.9 6.6 4.4<br>Type H1 H2 H3 H4 H5 H6<br>CPX-M 116 109 109.5 55.1 46.55 10.8<br>Type L1 [1)] L2 L3 [2)] L4 L5 [3)] L6 L7 L8 L9 L10 L11<br>CPX-M nx50.1+30.4 150.3 125.25 50.1 30.4 6.75 4.5 4 1.5 1 20<br>**----- End of picture text -----**<br>
- 1) n = Number of CPX modules
Subject to change – 2023/10
242
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet
**==> picture [523 x 610] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions Download CAD data a www.festo.com<br>With bus node and valve terminal VTSA/VTSA-F/VTSA-F-CB<br>[1] Solenoid valve, width 18 mm [7] Threaded connection G1/4 [16] CPX module/bus node [22] Additional mounting bracket<br>[2] Solenoid valve, width 26 mm [8] Threaded connection G1/8 [17] 90°-connection plate 43 mm, [23] Hole for additional mounting,<br>[3] Solenoid valve, width 42 mm [9] H-rail G3/8 diameter 6.4 2x<br>[4] Cover cap/manual override [10] H-rail mounting [18] 90°-connection plate [24] Solenoid valve, width 52 mm<br>[5] Threaded connection G1/2 [11] Mounting hole 54 mm, G1/4 [25] Supply plate<br>[6] Threaded connection G3/8 [12] Additional mounting bracket [19] Proximity switch M12x1 [26] Soft-start valve<br>[13] Inscription label holder [20] Plug socket M12x1<br>[14] Pneumatic interface CPX [21] Electrical connection to<br>[15] End plate EN 175301-803, type C<br>Dim. B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B16 B18 B19 B20 B21 B22 B23 B24<br>[mm] 107.3 142 121 57 46 33 18 48 26 78 66 12 29.6 23 19.5 10.5 6.6 4.5 65 18.9 7.5 4.4<br>Dim. L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L17 L18 L19 L20 L21 L22<br>[mm] 92.4 50 n2x59 n01x54 54 n1x43 43 mx50.1 n02x38 nx38 38 37.3 1 20.5 22 22 6.3 5.5 3 2<br>Dim. L23 L24 L25 H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 H12 H13 H14 H15 H16 H17 H18 H19<br>[mm] 30.4 23.7 1.5 143.9 133.3 125 121.3 118.2 103 106.8 87 90.3 92.9 55.1 65 25.8 25.7 24.5 12 6 3.5 10.8<br>Width L1 [1)]<br>40 mm 30.4 + m x 50.1 + 50 + n02 x 38 + n x 38 + 37.3<br>26 mm 30.4 + m x 50.1 + 50 + n01 x 54 + n x 38 + 37.3<br>42 mm 30.4 + m x 50.1 + 50 + n1 x 43 + n x 38 + 37.3<br>52 mm 30.4 + m x 50.1 + 50 + n2 x 59 + n x 38 + 37.3<br>Mixture of 18 mm, 26 mm, 42 mm and 52 mm 30.4 + m x 50.1 + 50 + n02 x 38 + n01 x 54 + n1 x 43 + n2x59 + n x 38 + 37.3<br>**----- End of picture text -----**<br>
- 1) n02 Number of manifold sub-bases 38 mm n01 Number of manifold sub-bases 54 mm n1 Number of manifold sub-bases 43 mm
- n2 Number of manifold sub-bases 59 mm
- n Number of supply plates (only with end plate with pilot air selector) m Number of CPX modules
- -H- Note: This product conforms to ISO 1179-1 and ISO 228-1.
2023/10 – Subject to change
243
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet
**==> picture [523 x 572] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions Download CAD data a www.festo.com<br>With bus node and valve terminal MPA-S<br>[1] Solenoid valve, width 10 mm [5] Supply/exhaust ports [11] CPX module [19] Vertical stacking MPA1<br>[2] Solenoid valve, width 20 mm [6] Working ports [12] Earthing screw [20] Vertical stacking MPA2<br>[3] Solenoid valve, width 14 mm [7] H-rail [13] Electrical supply plate<br>[4] Manual override [8] H-rail mounting [14] Pressure sensor<br>[9] Mounting holes [15] Proportional pressure regulator<br>[10] Pneumatic interface VMPA‐FB<br>Type B1 B2 B3 B5 B6 B7 B8 B9 B11 B12 B13 B14 B15 B16 B17 D1 D2<br>MPA-S 107.3 178 149.2 129 66.4 33.5 65 23.5 6.6 4.4 11 6.6 18 11 6.6 M6 M4<br>Type H1 H5 H7 H8 H9 H10 H11 H12 H13 H14 H15 H16 H17 H18 H19 H20 H21<br>MPA-S 132.3 84.9 23.9 23.1 10.8 9.8 45.1 23.9 22.1 20.3 9.8 8.7 8.2 22.6 22.9 9.9 93.4<br>Type L1 [1)] L2 L3 [2)] L4 L5 [3)] L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16<br>MPA-S m x 50.1 51.3 n x 42 32 o x 65.5 17.9 20 30 7.9 6.8 8.5 9 14.5 1.5 13.5 1<br>Type L17 L18 L19 L20 L21 L22 L23 L24 L25 L26 L27 L28 L29 L30 L31 L32 L33<br>MPA-S 21 21 5.3 10.5 11.9 16.6 18 18 7.6 12.6 14.8 14.8 9 15.8 30.4 42 27<br>**----- End of picture text -----**<br>
- 1) m = Number of CPX modules
- 2) n = number of sub-bases with 4 valve positions (width 10 mm) or 2 valve positions (width 20 mm)
- 3) o = number of sub-bases with 4 valve positions (width 14 mm)
Subject to change – 2023/10
244
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Data sheet
**==> picture [523 x 617] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions Download CAD data a www.festo.com<br>With bus node and valve terminal MPA-L<br>[1] Solenoid valve VMPA1 [5] Supply module [9] Mounting holes [11] CPX module<br>[2] Solenoid valve VMPA14 [6] Working ports [10] Pneumatic interface, [12] Earthing screw<br>[3] Solenoid valve VMPA2 [7] H-rail CPX terminal<br>[4] Manual override [8] H-rail mounting<br>Type L1 [1)] L2 [1)] L3 [1)] L4 [1)] , L5 L6 L7 L8 L9<br>MPA-L 170.65 + L2 + L3 + L4 m x 10.7 n x 14.9 o x 21.2 142 50 40.1 21.2 28.8<br>Type L10 L11 L12 L13 L14 L15 L16 L17 L18 L19 L20<br>MPA-L 24 30 10.7 14.9 21.2 8.5 6.75 5.55 6.5 1.5 1<br>Type B1 B2 , B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13<br>MPA-L 175.1 147.8 124 107.3 66.3 65 33.5 23.45 15 12.95 7.5 5.25 5.5<br>Type D1 D2 D3 H1 H2 , H3 H4 H5 H6 H7 H8<br>MPA-L 6.6 4.4 7 138.7 92.6 65.7 52 39.8 28.5 25.8 8.5<br>**----- End of picture text -----**<br>
- 1) m, n, o = number of sub-bases/valve positions (m = width 10 mm, n = width 14 mm, o = width 20 mm)
2023/10 – Subject to change
245
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Accessories
## **Ordering data – Accessories**
|Accessories|Accessories|Accessories|Accessories|Accessories|Accessories|Accessories|
|---|---|---|---|---|---|---|
|**Ordering data – Accessories**<br>Designation<br>Part no.<br>Type<br>Connectors and accessories<br>~~Re~~|||||||
|~~R~~<br>; <br>’|Sub-D plug for INTERBUS<br>~~Re~~|||Incoming<br>~~e~~|**532218**<br>~~e~~|**FBS-SUB-9-BU-IB-B**<br>~~e~~|
|||||Outgoing<br>~~es~~|**532217**<br>~~es~~|**FBS-SUB-9-GS-IB-B**<br>~~es~~|
||Sub-Dplugfor DeviceNet/CANopen<br>~~es~~<br>~~a~~||||**532219**<br>~~es~~|**FBS-SUB-9-BU-2x5POL-B**<br>~~es~~|
||Sub-Dplugfor PROFIBUS DP<br> ~~a~~<br>~~**a**~~||||**532216**|**FBS-SUB-9-GS-DP-B**|
||Sub-Dplugfor CC-Link<br> ~~**a**~~||||**532220**|**FBS-SUB-9-GS-2x4POL-B**<br>~~O~~|
||Sub-Dplug<br>~~a~~||||**534497**<br>~~a~~<br>~~(~~|**FBS-SUB-9-GS-1x9POL-B**<br>~~O~~<br>~~a~~<br>~~(~~|
|~~a~~<br>|Bus connection M12 adapter (B-coded) for PROFIBUS DP<br>~~a~~<br>~~a~~||||**533118**<br>~~a~~<br>~~(~~|**FBA-2-M12-5POL-RK**<br>~~a~~<br>~~(~~|
||Micro style bus connection, 2xM12 for DeviceNet/CANopen<br>~~a~~<br>~~es ee~~<br>||||**525632**<br>~~ee~~<br>|**FBA-2-M12-5POL**<br>~~es~~<br>|
|~~a~~<br>|For micro style connection, M12<br>~~a~~<br>~~a~~<br>|||Socket<br>~~es~~<br>~~es ee~~<br>|**18324**<br>~~es~~<br>~~ee~~<br>|**FBSD-GD-9-5POL**<br>~~es~~<br>~~es~~<br>|
|||||Plug<br>~~es~~<br>~~es ee~~<br>|**175380**<br>~~es~~<br>~~ee~~<br>|**FBS-M12-5GS-PG9**<br>~~es~~<br>~~es~~<br>|
||M12x1 bus connection, 4-pin (D-coded) for Ethernet<br>~~es~~<br>~~a~~<br>~~es ee~~<br> ~~a~~||||**543109**<br>~~es~~<br>~~ee~~<br>~~a~~|**NECU-M-S-D12G4-C2-ET**<br>~~es~~<br>~~es~~<br>~~a~~|
||For FBA-2-M12-5POL-RK and CPX-AB-2-M12-RK-DP, M12x1, 5-pin, straight<br>~~eee~~|||Socket<br>~~eee~~|**1067905**<br>~~eee~~|**NECU-M-B12G5-C2-PB**<br>~~eee~~|
|||||Plug<br>~~eee~~|**1066354**<br>~~eee~~|**NECU-M-S-B12G5-C2-PB**<br>~~eee~~|
||Plug M12x1, 4-pin,<br>straight, A-coded|Screw terminal|Connection cross section 0.14 ... 0.5 mm2<br>~~a~~||**192008**<br>~~a~~|**SEA-4GS-7-2.5**<br>~~a~~|
||||Permissible cable@4 ... 6 mm<br>~~es~~||**18666**<br>~~es~~|**SEA-GS-7**<br>~~es~~|
||||Permissible cable@6 ... 8 mm<br>~~es~~||**18778**<br>~~es~~|**SEA-GS-9**<br>~~es~~|
|~~o ee~~|Connection block, 9-pin Sub-D socket, 5-pin 7/8" plug for DeviceNet<br>~~es~~<br>~~ee~~||||**571052**<br>~~es~~|**CPX-AB-1-7/8-DN**<br>~~es~~|
|&-<br>~~o ee~~|Connection block M12 adapter (B-coded)<br>~~ee~~|||For PROFIBUS DP|**541519**|**CPX-AB-2-M12-RK-DP**|
|~~o ee~~<br>Z|Open style bus connection for 5-pin terminal strip for DeviceNet/CANopen<br>~~ee~~||||**525634**|**FBA-1-SL-5POL**|
|Ng|Terminal strip for open style connection, 5-pin||||**525635**|**FBSD-KL-2x5POL**|
||8-pin socket|||Spring-loaded termi-<br>nal|**565712**|**NECU-L3G8-C1**|
|||||Screw terminal|**565710**|**NECU-L3G8-C2**|
|~~CT~~|RJ45/plug<br>~~ee~~<br>~~CT~~||||**534494**<br>~~|~~|**FBS-RJ45-8-GS**<br>~~|~~|
|~~CT~~|RJ45plug, 8-pin,push-pull<br>~~CT~~||||**552000**<br>~~|~~|**FBS-RJ45-PP-GS**<br>~~|~~—‘(ti‘SsCszr|
||Plug SCRJ, 2-pin, push-pull, for CPX-M-FB45<br>~~CT~~||||**571017**<br>~~=~~<br>~~|~~|**FBS-SCRJ-PP-GS**<br>~~|~~|
||Plug for CAN bus interface, electric axes<br>Sub-D, 9-pin, without terminating resistor||||**533783**|**FBS-SUB-9-WS-CO-K**|
|Lae<br>~~|Sub-D socket with terminatingresistor andprogramminginterface|||For CANopen|**574588**|**NECU-S1W9-C2-ACO**|
||Sub-D plug, straight, with terminating resistor and programming interface|||For PROFIBUS|**574589**|**NECU-S1W9-C2-APB**|
Subject to change – 2023/10
246
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Accessories
## **Ordering data – Accessories**
**==> picture [523 x 537] intentionally omitted <==**
**----- Start of picture text -----**<br>
Designation Part no. Type<br>Distributor<br>Modular system for all types of sensor/actuator distributor – NEDY- ...<br>a Internet: nedy<br>Push-in T-connector 1x plug M8, 4-pin 2x socket M8, 3-pin 8005312 NEDY-L2R1-V1-M8G3-N-M8G4<br>1x plug M12, 4-pin 2x socket M8, 3-pin 8005311 NEDY-L2R1-V1-M8G3-N-M12G4<br>2x socket M12, 5-pin 8005310 NEDY-L2R1-V1-M12G5-N-M12G4<br>Connecting cables<br>Modular system for a choice of connecting cables – NEBU- ...<br>a Internet: nebu<br>Connecting cable M8-M8, 0.5 m 541346 NEBU-M8G3-K-0.5-M8G3<br>straight plug/straight socket 1.0 m 541347 NEBU-M8G3-K-1-M8G3<br>2.5 m 541348 NEBU-M8G3-K-2.5-M8G3<br>5.0 m 541349 NEBU-M8G3-K-5-M8G3<br>Connecting cable M12-M12, 5-pin, 1.5 m 529044 KV-M12-M12-1.5<br>straight plug/straight socket 3.5 m 530901 KV-M12-M12-3.5<br>Connecting cable for CPX-CTEL, M12-M12, 5-pin, straight plug/straight 5 m 574321 NEBU-M12G5-E-5-Q8N-M12G5<br>socket 7.5 m 574322 NEBU-M12G5-E-7.5-Q8N-M12G5<br>10 m 574323 NEBU-M12G5-E-10-Q8N-M12G5<br>Connecting cable M12-M12, 8-pin, 2.0 m 525617 KM12-8GD8GS-2-PU<br>straight plug/straight socket<br>Connecting cable M9, 5-pin, angled plug/open cable end 3-pin 2 m 563711 NEBC-M9W5-K-2-N-LE3<br>5 m 563712 NEBC-M9W5-K-5-N-LE3<br>Connecting cable M9, 0.25 m 540327 KVI-CP-3-WS-WD-0.25<br>angled plug/angled socket 0.5 m 540328 KVI-CP-3-WS-WD-0.5<br>2 m 540329 KVI-CP-3-WS-WD-2<br>5 m 540330 KVI-CP-3-WS-WD-5<br>8 m 540331 KVI-CP-3-WS-WD-8<br>Connecting cable M9, 2 m 540332 KVI-CP-3-GS-GD-2<br>Straight plug/straight socket 5 m 540333 KVI-CP-3-GS-GD-5<br>8 m 540334 KVI-CP-3-GS-GD-8<br>Connecting cable, Straight plug, M12x1, 0.5 m 8040446 NEBC-D12G4-ES-0.5-S-D12G4-ET<br>straight plug, M12x1, 4-pin, D-cod- 4-pin, D-coded 1 m 8040447 NEBC-D12G4-ES-1-S-D12G4-ET<br>ed 3 m 8040448 NEBC-D12G4-ES-3-S-D12G4-ET<br>5 m 8040449 NEBC-D12G4-ES-5-S-D12G4-ET<br>10 m 8040450 NEBC-D12G4-ES-10-S-D12G4-ET<br>Straight plug, RJ45, 8-pin 1 m 8040451 NEBC-D12G4-ES-1-S-R3G4-ET<br>3 m 8040452 NEBC-D12G4-ES-3-S-R3G4-ET<br>5 m 8040453 NEBC-D12G4-ES-5-S-R3G4-ET<br>10 m 8040454 NEBC-D12G4-ES-10-S-R3G4-ET<br>Open end, 4-wire 5 m 8040456 NEBC-LE4-ES-5-D12G4-ET<br>Connecting cable, Straight plug, RJ45, 8-pin 1 m 8040455 NEBC-R3G4-ES-1-S-R3G4-ET<br>Straight plug, RJ45, 8-pin<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
247
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
## Accessories
|**Ordering data – Accessories**<br>Designation<br>Part no.<br>Type<br>Connectors and accessories – Power supply<br>~~or~~<br>~~—~~|**Ordering data – Accessories**<br>Designation<br>Part no.<br>Type<br>Connectors and accessories – Power supply<br>~~or~~<br>~~—~~|**Ordering data – Accessories**<br>Designation<br>Part no.<br>Type<br>Connectors and accessories – Power supply<br>~~or~~<br>~~—~~|**Ordering data – Accessories**<br>Designation<br>Part no.<br>Type<br>Connectors and accessories – Power supply<br>~~or~~<br>~~—~~|**Ordering data – Accessories**<br>Designation<br>Part no.<br>Type<br>Connectors and accessories – Power supply<br>~~or~~<br>~~—~~|
|---|---|---|---|---|
|~~or~~|Plug socket for mains connection M18, straight<br>~~or~~|For 1.5 mm2<br>~~or~~<br>~~———~~<br>~~—~~|**18493**<br>~~or~~|**NTSD-GD-9**<br>~~or~~<br>~~oe~~|
|||For 2.5 mm2<br>~~———~~<br>~~—~~|**18526**|**NTSD-GD-13.5**<br>~~oe~~|
|,<br>|Plug socket for mains connection M18, angled<br>~~==~~|For 1.5 mm2<br>~~—~~|**18527**|**NTSD-WD-9**<br>~~oe~~|
|||For 2.5 mm2<br>~~==~~|**533119**<br>~~==~~|**NTSD-WD-11**<br>~~==~~|
|\<br>|Power supply socket, straight<br>~~==~~|7/8" connection, 5-pin<br>~~—~~<br>~~==~~|**543107**<br>~~==~~|**NECU-G78G5-C2**<br>~~==~~|
|||7/8" connection, 4-pin<br>~~—~~<br>~~==~~|**543108**<br>~~==~~|**NECU-G78G4-C2**<br>~~==~~|
|we<br>6<br>|7/8" power supply socket, 5-pin, angled socket/open cable end,<br>5-wire<br>~~==~~|2 m<br>~~==~~<br>~~es~~|**573855**<br>~~==~~|**NEBU-G78W5-K-2-N-LE5**<br>~~==~~|
|~~5~~|Power supplysocket M12x1, L-coded, straight<br>~~==~~|5-pin<br>~~==~~<br>~~es~~|**8166793**<br>~~==~~|**NECL-L12G5-C2-Q10**<br>~~==~~|
||Power supply plug M12x1, L-coded, straight<br>~~==~~|5-pin<br>~~==~~<br>~~es~~|**8166791**<br>~~==~~|**NECL-S-L12G5-C2-Q10**<br>~~==~~|
|~~5~~<br>es<br>~~3~~|Power supplysocket M12x1, L-coded, angled<br>~~==~~|5-pin<br>~~==~~|**8166794**<br>~~==~~|**NECL-L12W5-C2-Q10**<br>~~==~~|
||Power supply plug M12x1, L-coded, angled<br><br>~~3~~|5-pin<br><br>~~3~~|**8166792**<br><br>~~3~~|**NECL-S-L12W5-C2-Q10**<br><br>~~3=~~|
|~~3~~|Push-pull power supply socket, plug pattern PP, fulfils require-<br>ments to AIDA<br>~~3~~|5-pin<br>~~3~~|**5195383**<br>~~3~~|**NECU-M-PPG5PP-C1-PN**<br>~~3=~~|
|~~3~~|Straight plug, spring-loaded terminal, for left-hand end plate<br>with system supply<br>~~3~~|7-pin<br>~~3~~|**576319**<br>~~3~~|**NECU-L3G7-C1**<br>~~3~~|
|~~[sss~~<br>~~3~~|||||
|Hood<br>~~3~~|||||
|~~3~~|Mounting rail for attaching the hood<br>~~3~~|1000 mm<br>~~3~~|**572256**<br>~~3~~|**CAFC-X1-S**<br>~~3~~|
||Mounting kit for CPX hood||**572257**|**CAFC-X1-BE**<br>~~el~~|
|~~>~~|Hood section for CPX terminal including mounting attachments<br>for connecting several hood sections in series<br>~~>~~|200 mm|**572258**|**CAFC-X1-GAL-200**<br>~~el~~|
|||300 mm<br>~~>~~|**572259**<br>~~>~~|**CAFC-X1-GAL-300**<br>~~>~~<br>~~el~~|
||||||
|Screws<br>~~Sooo~~|||||
|Ke<<a<br>~~=~~|Screws for mounting the bus node/connection block on the plas-<br>tic interlinkingblock<br>~~——~~|Bus node/metal connection<br>block<br>~~—~~|**550218**|**CPX-DPT-30X32-S-4X**|
||Screws for mounting the bus node/connection block on the met-<br>al interlinking block<br>~~——~~|Bus node/plastic connection<br>block<br>~~—~~|**550219**|**CPX-M-M3x22-4x**|
|||Bus node/metal connection<br>block<br>~~—~~|**550216**|**CPX-M-M3x22-S-4x**|
|~~=~~|Screws for mounting an inscription label on the bus node<br>CPX-M-FB45<br>~~——~~|12 pieces<br>~~—~~|**550222**|**CPX-M-M2.5X8-12X**|
Subject to change – 2023/10
248
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Accessories
**==> picture [524 x 548] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data – Accessories<br>Designation Part no. Type<br>Mounting<br>Attachment for wall mounting (for long valve terminals, Version for manifold sub-bases 529040 CPX-BG-RW-10x<br>10 pieces)<br>Attachment for wall mounting, version for metal manifold 2 mounting brackets, 4 screws 550217 CPX-M-BG-RW-2X<br>sub-bases 1 mounting bracket, 2 screws 2721419 CPX-M-BG-VT-2X<br>Covers and attachments<br>Cover for CPX-AB-8-KL-4POL (IP65, IP67) 538219 AK-8KL<br>• 8 cable through feeds M9<br>• 1 cable through feed for multi-pin plug<br>Fittings kit 538220 VG-K-M9<br>Screening plate for M12 connections 526184 CPX-AB-S-4-M12<br>Earthing element (5 pieces), for right-hand/left-hand end plate 538892 CPX-EPFE-EV<br>(plastic interlinking blocks)<br>Inspection cover, transparent 533334 AK-SUB-9/15-B<br>Transparent cover for DIL switch 548757 CPX-AK-P<br>Cover for DIL switch 548754 CPX-M-AK-M<br>Cover for RJ45 connection 534496 AK-RJ45<br>Cover cap for RJ45 push-pull connection 548753 CPX-M-AK-C<br>Cover cap for bus connection 2873540 CPX-M-AK-D<br>Cover cap for closing off unused connections (10 pieces) For M8 connections 177672 ISK-M8<br>For M12 connections 165592 ISK-M12<br>Coding element, so that a coded socket NECU-L3G8 can only be For NECU-L3G8 565713 CPX-P-KDS-AB-2XKL<br>inserted in the matching coded connection block CPX-P-AB-2XKL<br>(96 of each)<br>**----- End of picture text -----**<br>
2023/10 – Subject to change
249
d **Internet: www.festo.com/catalogue/...**
Terminal CPX
**==> picture [596 x 40] intentionally omitted <==**
## Accessories
**==> picture [524 x 490] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering data – Accessories<br>Designation Part no. Type<br>Function blocks<br>Terminating resistor, M12, B-coded for PROFIBUS 1072128 CACR-S-B12G5-220-PB<br>PT1000 temperature sensor for cold junction compensation 553596 CPX-W-PT1000<br>5-pin M12 to mini USB socket adapter and controller software 547432 NEFC-M12G5-0.3-U1G5<br>Inscription labels<br>Inscription labels 6x10 mm, 64 pieces, in frame 18576 IBS-6x10<br>Inscription label holder for connection block 536593 CPX-ST-1<br>Multi-pin plug distributor<br>Sub-D plug, 15-pin 8x socket M8, 3-pin 177669 MPV-E/A08-M8<br>12x socket M8, 3-pin 177670 MPV-E/A12-M8<br>Plug M12, 8 pin 4x socket M8, 3-pin 574586 NEDU-L4R1-M8G3L-M12G8<br>6x socket, M8, 3-pin 574587 NEDU-L6R1-M8G3L-M12G8<br>Connecting cable for multi-pin plug distributor<br>Sub-D socket, 15-pin 5 m 177673 KMPV-SUB-D-15-5<br>Open cable end, 15-wire 10 m 177674 KMPV-SUB-D-15-10<br>Angled socket, M12, 8-pin, Length: 2 m 542256 NEBU-M12W8-K-2-N-LE8<br>Open cable end, 8-wire Length: 5 m 542257 NEBU-M12W8-K-5-N-LE8<br>Length: 10 m 570007 NEBU-M12W8-K-10-N-LE8<br>Straight socket, M12, 8-pin, Length: 2 m 525616 SIM-M12-8GD-2-PU<br>Open cable end, 8-wire Length: 5 m 525618 SIM-M12-8GD-5-PU<br>Length: 10 m 570008 SIM-M12-8GD-10-PU<br>**----- End of picture text -----**<br>
Subject to change – 2023/10
250
d **Internet: www.festo.com/catalogue/...**
Updated at June 9, 2026
Festo is a globally recognized leader in industrial automation, renowned for its innovative pneumatic and electrical control and drive technologies. As an engineering-driven company, Festo provides robust, high-quality components designed to optimize both factory and process automation systems across a wide range of demanding industries. A cornerstone of their automation expertise is a comprehensive portfolio of precision sensory technology. The core of this offering is focused on advanced pressure sensors and transducers. These vital components are engineered to deliver highly accurate fluid and gas measurements, ensuring reliable monitoring, system safety, and optimal efficiency in complex industrial environments. Complementing their fluid control solutions, Festo also manufactures a dependable selection of proximity sensors and proximity switches. Built for durability and precise object detection, these sensors provide the essential positional feedback required to maintain seamless and automated operational workflows.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →