5500.2611.04
Power Line Filter, Medical, 250 VAC, 3 A, Single Phase, 2 Stage, Chassis Mount
- Manufacturer: SCHURTER
- Product type:
- SVHC: No SVHC (04-Feb-2026)
- No. of Phases: Single Phase
- No. of Stages: 2 Stage
- Product Range: FMBB NEO Series
- Current Rating: 3A
- Voltage Rating: 250VAC
- Filter Mounting: Chassis Mount
- Filter Applications: Medical
- Filter Input Terminals: Quick Connect
- Filter Output Terminals: Quick Connect
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 27.71 € |
| Current stock | 10+ |
| Lead time | 30 days |
**1-Phase Line Filters** FMBB NEO https://www.schurter.com /PG84 AC Filter 2-Stage, Broad Band Attenuation Quick connect terminals 6.3x0.8 mm Case MB Quick connect terminals 6.3x0.8 mm Case MF Quick connect terminals 6.3x0.8 mm Case 09 See below: **Approvals and Compliances** ## **Description** - Line filter in standard and medical version - 2 stage - 3 Designs: - C) high symmetrical and asymmetrical noise attenuation D) Excellent high frequency noise attenuation - F) Excellent low frequency noise attenuation ## **Unique Selling Proposition** - Broad band attenuation - 3 Filter designs for various applications - Completely closed steel housing - Wide temperature range ## **Characteristics** - Designed for current applications of 1 - 36 A - Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated - Especially designed for industrial applications such as: Frequency Converters, Stepper Motor Drives, UPS-Systems, Inverters - Suitable for use in equipment according to IEC/UL 62368-1 Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP, 1 MOPP) ## **Other versions on request** - Version with wire connection - Version with varistor for overvoltage protection ## **Weblinks** pdf data sheet, html datasheet, General Product Information, Approvals, Distributor-Stock-Check, Detailed request for product, Microsite |**Technical Data**|||| |---|---|---|---| |Ratings IEC|1-36 A @ Ta 40°C / 250 VAC; 50 Hz|Line Filter|Standard and Medical Version, IEC| |Ratings UL/CSA|1 - 30 A @ Ta 40 °C / 125/250 VAC;||60939, UL 1283, CSA C22.2 no. 8| ||60 Hz||Technical Details| |Leakage Current|standard < 0.5 mA (250 V / 60 Hz)|MTBF|> 200'000 h acc. to MIL-HB-217 F| ||medical (M5) < 5 µA resp. (M80) < 80||| ||µA (250 V / 60 Hz)||| |Dielectric Strength|1.7 kVDC between L-N||| ||2.75 kVDC between L/N-PE||| ||Test voltage (2 sec)||| |Allowable Operation Tempe-|-40 °C to 100 °C||| |rature|||| |Climatic Category|40/100/21 acc. to IEC 60068-1||| |IP-Protection|IP20 IEC 60529||| |Protection Class|Suitable for appliances with protection||| ||class I acc. to IEC 61140||| |Terminal|Quick connect terminal 6.3 x 0.8 mm||| ||Bolt and nut M4||| |Material|Nickel plated steel||| ## **Approvals and Compliances** Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER. EMC Products **1** **1-Phase Line Filters** https://www.schurter.com /PG84 FMBB NEO ## **Approvals** The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: FMBB NEO |**Approval Logo**|**Approval Logo**|**Certificates**|**Certification Body**|**Description**| |---|---|---|---|---| |KE|KE|VDE Approvals|VDE|Certificate Number: 40030410| |||UL Approvals|UL|UR File Number: E72928| |**Product standards**|**Product standards**|||| |Product standards that are referenced|Product standards that are referenced|||| |**Organization**||**Design**|**Standard**|**Description**| |||Designed according to|IEC 60939|Passive filters for suppressing electromagnetic interference| |||||| |||Designed according to|IEC 60127-6|Miniature fuses. Part 6. Fuse-holders for miniature fuse-links| |||Designed according to|UL 1283|Passive filters for suppressing electromagnetic interference| |||Designed according to|CSA C22.2 no. 8|Electromagnetic interference (EMI) filters| |**Application standards**|**Application standards**|||| |Application standards where the product can be used|Application standards where the product can be used|||| |**Organization**||**Design**|**Standard**|**Description**| |||Suitable for applications acc.|IEC/UL 62368-1|Audio/video, information and communication technology equipment - Part<br>1: Safety requirements| |||Suitable for applications acc.|IEC 60601-1|Medical electrical equipment - Part 1: General requirements for basic<br>safety and essential performance| |**Compliances**|**Compliances**|||| |The product complies with following Guide Lines|The product complies with following Guide Lines|||| |**Identification**||**Details**|**Initiator**|**Description**| |CE|CE|CE declaration of conformity|SCHURTER AG|The CE marking declares that the product complies with the applicable<br>requirements laid down in the harmonisation of Community legislation on| |||||its affixing in accordance with EU Regulation 765/2008.| |UK|UK|UKCA declaration of conformity|SCHURTER AG|The UKCA marking declares that the product complies with the applicable| |cA|cA|||requirements laid down in the British Amendment of Regulation (EC)| |||||765/2008.| |||RoHS|SCHURTER AG|Directive RoHS 2011/65/EU, Amendment (EU) 2015/863| |~~©~~|~~©~~|China RoHS|SCHURTER AG|The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March<br>2007. It is similar to the EU directive RoHS.| |||REACH|SCHURTER AG|On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,| |||||Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as| |||||"REACH") entered into force.| |||Medical Equipment|SCHURTER AG|Suitable for use in medical equipment according to IEC/UL 60601-1 (1| |||||MOOP, 1 MOPP)| ## **Product standards** Product standards that are referenced ## **Application standards** Application standards where the product can be used ## **Compliances** The product complies with following Guide Lines | **2** | EL.SCHURTER | EMC Products **1-Phase Line Filters** FMBB NEO https://www.schurter.com /PG84 ## **Dimension [mm]** Case 09 with quick connect terminals **==> picture [292 x 165] intentionally omitted <==** **----- Start of picture text -----**<br> max. 77 max. 46<br>27 max. 52 17.5<br>60.4 [±0.5]<br>6.3x0.8<br>1) 2)<br>(5x)<br>7.5<br>12 max. 31<br>±0.3<br>4.8 (2x)<br>**----- End of picture text -----**<br> ## 1) Line 2) Load Case MB with quick connect terminals **==> picture [384 x 227] intentionally omitted <==** **----- Start of picture text -----**<br> max. 156 max. 58<br>27 max. 131 15.2<br>max. 156<br>144 [±0.5]<br>140 [±0.5]<br>6.3x0.8<br>(5x)<br>1) 2)<br>13<br>max. 46<br>12<br>±0.3<br>5.3 (2x)<br>**----- End of picture text -----**<br> 1) Line 2) Load EMC Products **3** **1-Phase Line Filters** https://www.schurter.com /PG84 FMBB NEO Case MB with bolt and nut M4 **==> picture [388 x 231] intentionally omitted <==** **----- Start of picture text -----**<br> max. 160 max. 58<br>27 max. 131 15.2<br>4)<br>5)<br>max. 156<br>144 [±0.5]<br>140 ±0.5<br>3)<br>4) 1) 2)<br>13<br>max. 46<br>12<br>±0.3<br>5.3 (2x)<br>M4 (4x)<br>**----- End of picture text -----**<br> 1) Line ## 2) Load 3) Nut torque 0.8...1 Nm, keep lock-nut fastened 4) Lock-nut do not unscrew 5) PE: M4x16, 1.2...1.5 Nm, keep lock-nut fastened Case MC with quick connect terminals **==> picture [300 x 161] intentionally omitted <==** **----- Start of picture text -----**<br> max. 90 max. 51<br>27 max. 66 21<br>75 [±0.5]<br>6.3x0.8<br>(5x)<br>1) 2)<br>6<br>12 max. 31<br>±0.3<br>5.3 (2x)<br>**----- End of picture text -----**<br> 1) Line 2) Load EMC Products **4** **1-Phase Line Filters** https://www.schurter.com /PG84 FMBB NEO Case UB with quick connect terminals **==> picture [302 x 184] intentionally omitted <==** **----- Start of picture text -----**<br> max. 90 max. 51<br>27 max. 66 11.4<br>75 [±0.5]<br>6.3x0.8<br>(5x)<br>1) 2)<br>max.41 10.4<br>12<br>±0.3<br>5.3 (2x)<br>**----- End of picture text -----**<br> ## 1) Line 2) Load Case ME with quick connect terminals **==> picture [326 x 220] intentionally omitted <==** **----- Start of picture text -----**<br> max. 112 max. 52<br>27 max. 87 12<br>max. 115<br>104.5 [±0.5]<br>97.5 [±0.5]<br>6.3x0.8<br>(5x)<br>1) 2)<br>max. 46 13<br>12<br>±0.3<br>5.3 (2x)<br>**----- End of picture text -----**<br> 1) Line 2) Load EMC Products **5** **1-Phase Line Filters** https://www.schurter.com /PG84 FMBB NEO Case MF with quick connect terminals **==> picture [390 x 253] intentionally omitted <==** **----- Start of picture text -----**<br> max. 123 max. 85<br>max. 98 40<br>max. 120<br>109 [±0.3] 4.4 [±0.3]<br>6.3x0.8<br>(5x) (4x)<br>1) 2)<br>16.1<br>max. 59<br> ±0.5 ±0.5<br>47.5 54.5<br>**----- End of picture text -----**<br> 1) Line 2) Load Case MF with bolt and nut M4 **==> picture [420 x 249] intentionally omitted <==** **----- Start of picture text -----**<br> max. 130 max. 85<br>max. 98 40<br>max. 120<br>109 [±0.3] 4.4 [±0.3]<br>(4x)<br>3)<br>5)<br>4) 1) 2)<br>max. 59<br>16<br> ±0.5 ±0.5<br>47.5 54.5<br>M4 (4x)<br>**----- End of picture text -----**<br> 1) Line 2) Load 3) Nut torque 0.8...1 Nm, keep lock-nut fastened 4) Lock-nut do not unscrew 5) PE: M4x16, 1.2...1.5 Nm, keep lock-nut fastened EMC Products **6** **1-Phase Line Filters** https://www.schurter.com /PG84 FMBB NEO Case with wire leads **==> picture [205 x 143] intentionally omitted <==** **----- Start of picture text -----**<br> 140 [±5] 140 [±5]<br>L L'<br>1) 2)<br>3) PE 3)<br>4) N N'<br>5) 5)<br> 1 - 3 A © AWG 20<br> 6 - 10 A © AWG 18<br> 12 - 16 A © AWG 16<br> 20 A © AWG 14<br> 25 - 30 A © AWG 12<br> 36 A © AWG 10<br>**----- End of picture text -----**<br> 1) Line 2) Load 3) Brown 4) Yellow-Green 5) Blue ## **Diagrams** Design C, D Standard and medical M80 Design C, D Medical M5 **==> picture [244 x 98] intentionally omitted <==** **----- Start of picture text -----**<br> 1) 2)<br>1) Line, 2) Load<br>**----- End of picture text -----**<br> **==> picture [244 x 103] intentionally omitted <==** **----- Start of picture text -----**<br> 1) 2)<br>1) Line, 2) Load<br>**----- End of picture text -----**<br> Design F Standard and medical M80 Design F Medical M5 **==> picture [244 x 111] intentionally omitted <==** **----- Start of picture text -----**<br> 1) 2)<br>1) Line, 2) Load<br>**----- End of picture text -----**<br> **==> picture [244 x 117] intentionally omitted <==** **----- Start of picture text -----**<br> 1) 2)<br>1) Line, 2) Load<br>**----- End of picture text -----**<br> EMC Products **7** **1-Phase Line Filters** https://www.schurter.com /PG84 ## FMBB NEO **Attenuation Loss** . . . . . 0.1/100 Ω differential mode ........... 100/0.1 Ω differential mode - - - - 50 Ω differential mode _____ 50 Ω common mode Standard version 1 A / Design C 3 A / Design C 6 A / Design C 10 A / Design C 12 A / Design C 16 A / Design C dB 4B 80 fe Til 80 ©- CEATe ge iefay ec imnacced ” oeaiiiliet anes -20 ! t -20 0.01 (rn rr 100 400 MHz 0.01 (nr 1 A / Design PE 3 A / Design D 20 A / Design C 6 A / Design D 30 A / Design C 10 A / Design D 12 A / Design D 16 A / Design D 25 A / Design D 36 A / Design D 1 A / Design F 3 A / Design F dB dB 80 Poa TT 80 AHL °C TN Ce 40 Ba, mea 40 He oHatl) |ieswy =eLd Se -20 t -20 0.01 (rn rr 100 400 MHz 0.01 (rn 12 A / Design F 16 A / Design F 6 A / Design F 10 A / Design F EMC Products **8** **1-Phase Line Filters** https://www.schurter.com /PG84 FMBB NEO Medical version (M5) 1 A / Design C 3 A / Design C 6 A / Design C 10 A / Design C 4B 4B 4B dB oea 5sHEH eae es aH HEH Ee eae EH oo FEEEs aH oe HEH ° SUR Ys iae ° A oa © ao NTT NOT CSAS CUS) oooFH Hes 20o errataRCHa Nan Pe 200 EWEHtc **N** M 200 ao CHE ATH ao CER CEHHH ao CEL HEEFHT ao 0.01 01 1 10 100 400 MHz 0.01 041 1 10 100 400 MHz 0.01 041 1 10 100 400 MHz 0.01 041 12 A / Design C 16 A / Design C 20 A / Design C 30 A / Design C 1 A / Design PE 3 A / Design D 6 A / Design D 10 A / Design D 4B 4B dB dB a aH 5 HEH at as aH EEE ae Pra ka 1 peg eau evapo © eS oo era oa od © 020 AEONTHH Ai 09 RONCATE 0zo RTETLPtNag te 0Be dl > RAI o RAT oS ail a ao CEEA AEH wo CEEne ArH woEEA AHHH wo 0.01 01 1 10 100 400 MHz 0.01 01 1 10 100 400 MHz 0.01 01 1 10 100 400 MHz 0.01 01 12 A / Design D 16 A / Design D 25 A / Design D 36 A / Design D 4B 4B 4B dB eg0 SSSean owaaac oeTL HEH CoSRe SHCo ao oe CeEEA oaet aesath 1 oe EPH 20 er TTHSAeM ©oo brayaNAL He 020 LaEeHSATT enn20 Fae oR eo oa 0 Pe CO ao CHEE TH ao HEE we HEE HH ao CE 0.01 01 1 10 100 400 MHz 0.01 041 1 10 100 400 MHz 0.01 041 1 10 100 400 MHz 0.01 01 1 A / Design F 3 A / Design F 6 A / Design F 10 A / Design F 0 30 0 0 wo mEACE Teh wo eeee - wo CHU Heesa oo Ue © 22cm Cn esa TN Fee Cee Oa ATETTTth MATT ag ©eG CRTAl Ty «7 RATEAL TE tt TNA TAN 7 eT Og 000 a Ag 2 0 ao CIEA AH aoEEA AH aoCEA AHH ao 0.01 01 1 10 100 400 MHz 0.01 01 1 10 100 400 MHz 0.01 01 1 10 100 400 MHz 0.01 01 12 A / Design F 16 A / Design F EMC Products **9** **1-Phase Line Filters** https://www.schurter.com /PG84 ## FMBB NEO Medical version (M80) 1 A / Design C 3 A / Design C 6 A / Design C 10 A / Design C dB dB dB dB © HibsCHAR a © ETHIEEPA pees © EHHresot © EH “0 tt hal ech fines ot etd Potter bape TNS | 20 Bee SS RR “0 LEIA To TN “0 CAT TET Nah “0 CO Py FE as 20 Pat Hatt 20 a aeNe HE 20 Peet tT Py Sem ee aM PyPr Py ag EY BA oo20 LEH oo20 LEE Cee HEH oo20 LN CEE HH oo20 0.01 o1 1 10 100 400 MHz 0.01 01 1 10 100 400 MHz 0.01 01 1 10 100 400 MHz 0.01 01 12 A / Design C 16 A / Design C 20 A / Design C 30 A / Design C dB dB dB dB © HH © Aat © Hallas tha © EHH Feu “0| LavCO **e** e NSNal Mg 0 POEota TIE AMIAS| “0 etalea RAset Eneaw co LecE | a 0 TeeMEE 20 PA 2 anyMIE 20 | ° amie COMI MOTI OUT 0 Fat 0 see A ° no ELCEH no CRDtH noHH oo LE 0.01 o1 1 10 100 400 MHz 0.01 01 1 10 100 400 MHz 0.01 01 1 10 100 400 MHz 0.01 o1 1 A / Design PE 3 A / Design D 6 A / Design D 10 A / Design D dB dB dB dB ee |Sel[Aerie] ee © aS1 © Aaeo © A 0 keene LE rene coeeen ee re eta cae UNC Ae 0 ITM 0 i ad “0 A | 20 APSE 20 0 RA 0 eee ee Nt | 0 Let elt TTI TI TT 0 KA} eo COEtH oo SEH ooEH oo 0.01 01 1 10 100 400 MHz 0.01 01 1 10 100 400 MHz 0.01 01 1 10 100 400 MHz 0.01 01 12 A / Design D 16 A / Design D 25 A / Design D 36 A / Design D 20 - ly] = = a = 8 [nlleeacl ee voaa fo Ce see Esta ne 02 ACAdae acy tN RNanh “0 ISucr| footQu) omaol maOL «0 StaaTFe MARU Ma 0 |Te a 2 ee NATE 20 a 0 eee ailment 0 pe 0 ae de ee eee 0 Se ee ooEE woEE woEE oo 0.01 01 1 10 100 400 MHz 0.01 01 1 10 100 400 MHz 0.01 0.1 1 10 100 400 MHz 0.01 0.1 1 A / Design F 3 A / Design F 6 A / Design F 10 A / Design F 30 oh a 20 Rn a EE A 20 HH pete eee SEH Hi] 0 Ey oo Aare oo pee a aa AMD alii 1 SO © Ete UN yr mee i = ef els Sati ante Mame >> Ain 5Ba ; Bee TTT Try ° A Tet » SReERS, CESS Ae 0.01 01 1 10 100 400 MHz 0.01 01 1 10 100 400 MHz oo) a 40100 400 Miz 0.01 04 12 A / Design F 16 A / Design F **10** | ELSCHURTER | EMC Products **1-Phase Line Filters** https://www.schurter.com /PG84 FMBB NEO ## **Variants** **==> picture [515 x 718] intentionally omitted <==** **----- Start of picture text -----**<br> Rated Filter-Type Terminal Design L L1 Cx Cy Ri Power Weight Housing Packa- Order Number<br>current Loss ging<br>[A] [mH] [mH] [µF] [nF] [m Ω ] [W] [g] [ST]<br>1 Standard Quick connect terminal 6.3 x 0.8 mm C 12 - 0.22 4.7 945 1.9 125 g 09 15 5500.2600.01<br>3 Standard Quick connect terminal 6.3 x 0.8 mm C 2.5 - 0.22 4.7 120 2.2 130 g 09 15 5500.2601.01<br>6 Standard Quick connect terminal 6.3 x 0.8 mm C 0.97 - 0.22 4.7 26.2 1.9 130 g 09 15 5500.2602.01<br>10 Standard Quick connect terminal 6.3 x 0.8 mm C 0.8 - 0.47 4.7 12.9 2.6 200 g MC 10 5500.2603.01<br>12 Standard Quick connect terminal 6.3 x 0.8 mm C 0.58 - 0.47 4.7 10.1 2.9 200 g MC 10 5500.2604.01<br>16 Standard Quick connect terminal 6.3 x 0.8 mm C 0.65 - 0.33 4.7 8 4.1 265 g UB 10 5500.2605.01<br>20 Standard Quick connect terminal 6.3 x 0.8 mm C 0.6 - 1 4.7 4.6 3.7 390 g ME 5 5500.2606.01<br>30 Standard Bolt and nut M4 C 0.6 - 1 10 2.5 4.5 855 g MF 3 5500.2607.03<br>1 Standard Quick connect terminal 6.3 x 0.8 mm D 22 - 0.33 4.7 1320 2.7 165 g MC 10 5500.2610.01<br>3 Standard Quick connect terminal 6.3 x 0.8 mm D 9.8 - 0.47 4.7 226 4.1 225 g UB 10 5500.2611.01<br>6 Standard Quick connect terminal 6.3 x 0.8 mm D 7.8 - 1 4.7 55.4 4 350 g ME 5 5500.2612.01<br>10 Standard Quick connect terminal 6.3 x 0.8 mm D 4.5 - 1 4.7 23.6 4.7 625 g MB 4 5500.2613.01<br>12 Standard Quick connect terminal 6.3 x 0.8 mm D 3.25 - 1 4.7 16 4.6 630 g MB 4 5500.2614.01<br>16 Standard Quick connect terminal 6.3 x 0.8 mm D 2.8 - 1 4.7 10.9 5.6 826 g MF 3 5500.2615.01<br>25 Standard Bolt and nut M4 D 2.0 - 2.2 4.7 4.8 6 830 g MB 4 5500.2616.03<br>36 Standard Bolt and nut M4 D 1.23 - 2.2 4.7 3.3 8.5 810 g MB 4 5500.2617.03<br>1 Standard Quick connect terminal 6.3 x 0.8 mm F 22 0.49 0.33 4.7 1200 2.4 180 g MC 10 5500.2620.01<br>3 Standard Quick connect terminal 6.3 x 0.8 mm F 9.8 0.16 0.47 4.7 194 3.5 240 g UB 10 5500.2621.01<br>6 Standard Quick connect terminal 6.3 x 0.8 mm F 7.8 0.11 1 4.7 60 4.3 400 g ME 5 5500.2622.01<br>10 Standard Quick connect terminal 6.3 x 0.8 mm F 4.5 0.06 1 4.7 21 4.2 645 g MB 4 5500.2623.01<br>12 Standard Quick connect terminal 6.3 x 0.8 mm F 3.25 0.05 1 4.7 14.6 4.2 695 g MB 4 5500.2624.01<br>16 Standard Quick connect terminal 6.3 x 0.8 mm F 2.8 0.043 1 4.7 13.7 7 950 g MF 3 5500.2625.01<br>1 Medical (M5) Quick connect terminal 6.3 x 0.8 mm C 12 - 0.22 - 945 1.9 125 g 09 15 5500.2600.04<br>3 Medical (M5) Quick connect terminal 6.3 x 0.8 mm C 2.5 - 0.22 - 120 2.2 130 g 09 15 5500.2601.04<br>6 Medical (M5) Quick connect terminal 6.3 x 0.8 mm C 0.97 - 0.22 - 26.2 1.9 130 g 09 15 5500.2602.04<br>10 Medical (M5) Quick connect terminal 6.3 x 0.8 mm C 0.8 - 0.47 - 12.9 2.6 200 g MC 10 5500.2603.04<br>12 Medical (M5) Quick connect terminal 6.3 x 0.8 mm C 0.58 - 0.47 - 10.1 2.9 200 g MC 10 5500.2604.04<br>16 Medical (M5) Quick connect terminal 6.3 x 0.8 mm C 0.65 - 0.33 - 8 4.1 265 g UB 10 5500.2605.04<br>20 Medical (M5) Quick connect terminal 6.3 x 0.8 mm C 0.6 - 1 - 4.6 3.7 390 g ME 5 5500.2606.04<br>30 Medical (M5) Bolt and nut M4 C 0.6 - 1 - 2.5 4.5 855 g MF 3 5500.2607.06<br>1 Medical (M5) Quick connect terminal 6.3 x 0.8 mm D 22 - 0.33 - 1320 2.7 165 g MC 10 5500.2610.04<br>3 Medical (M5) Quick connect terminal 6.3 x 0.8 mm D 9.8 - 0.47 - 226 4.1 225 g UB 10 5500.2611.04<br>6 Medical (M5) Quick connect terminal 6.3 x 0.8 mm D 7.8 - 1 - 55.4 4 350 g ME 5 5500.2612.04<br>10 Medical (M5) Quick connect terminal 6.3 x 0.8 mm D 4.5 - 1 - 23.6 4.7 625 g MB 4 5500.2613.04<br>12 Medical (M5) Quick connect terminal 6.3 x 0.8 mm D 3.25 - 1 - 16 4.6 630 g MB 4 5500.2614.04<br>16 Medical (M5) Quick connect terminal 6.3 x 0.8 mm D 2.8 - 1 - 10.9 5.6 826 g MF 3 5500.2615.04<br>25 Medical (M5) Bolt and nut M4 D 2.0 - 2.2 - 4.8 6 830 g MB 4 5500.2616.06<br>36 Medical (M5) Bolt and nut M4 D 1.23 - 2.2 - 3.3 8.5 810 g MB 4 5500.2617.06<br>1 Medical (M5) Quick connect terminal 6.3 x 0.8 mm F 22 0.49 0.33 - 1200 2.4 180 g MC 10 5500.2620.04<br>3 Medical (M5) Quick connect terminal 6.3 x 0.8 mm F 9.8 0.16 0.47 - 194 3.5 240 g UB 10 5500.2621.04<br>6 Medical (M5) Quick connect terminal 6.3 x 0.8 mm F 7.8 0.11 1 - 60 4.3 400 g ME 5 5500.2622.04<br>10 Medical (M5) Quick connect terminal 6.3 x 0.8 mm F 4.5 0.06 1 - 21 4.2 645 g MB 4 5500.2623.04<br>12 Medical (M5) Quick connect terminal 6.3 x 0.8 mm F 3.25 0.05 1 - 14.6 4.2 695 g MB 4 5500.2624.04<br>16 Medical (M5) Quick connect terminal 6.3 x 0.8 mm F 2.8 0.043 1 - 13.7 7 950 g MF 3 5500.2625.04<br>1 Medical (M80) Quick connect terminal 6.3 x 0.8 mm C 12 - 0.22 0.47 945 1.9 125 g 09 15 5500.2600.07<br>3 Medical (M80) Quick connect terminal 6.3 x 0.8 mm C 2.5 - 0.22 0.47 120 2.2 130 g 09 15 5500.2601.07<br>6 Medical (M80) Quick connect terminal 6.3 x 0.8 mm C 0.97 - 0.22 0.47 26.2 1.9 130 g 09 15 5500.2602.07<br>10 Medical (M80) Quick connect terminal 6.3 x 0.8 mm C 0.8 - 0.47 0.47 12.9 2.6 200 g MC 10 5500.2603.07<br>12 Medical (M80) Quick connect terminal 6.3 x 0.8 mm C 0.58 - 0.47 0.47 10.1 2.9 200 g MC 10 5500.2604.07<br>16 Medical (M80) Quick connect terminal 6.3 x 0.8 mm C 0.65 - 0.33 0.47 8 4.1 265 g UB 10 5500.2605.07<br>20 Medical (M80) Quick connect terminal 6.3 x 0.8 mm C 0.6 - 1 0.47 4.6 3.7 390 g ME 5 5500.2606.07<br>30 Medical (M80) Bolt and nut M4 C 0.6 - 1 0.47 2.5 4.5 855 g MF 3 5500.2607.09<br>1 Medical (M80) Quick connect terminal 6.3 x 0.8 mm D 22 - 0.33 0.47 1320 2.7 165 g MC 10 5500.2610.07<br>**----- End of picture text -----**<br> EMC Products **11** **1-Phase Line Filters** FMBB NEO https://www.schurter.com /PG84 **==> picture [501 x 200] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---| |Rated|Filter-Type|Terminal|Design|L|L1|Cx|Cy|Ri|Power|Weight|Housing|Packa-|Order Number| |current|Loss|ging| |[A]|[mH]|[mH]|[µF]|[nF]|[m|Ω|]|[W]|[g]|[ST]| |3|Medical (M80)|Quick connect terminal 6.3 x 0.8 mm|D|9.8|-|0.47|0.47|226|4.1|225 g|UB|10|5500.2611.07| |6|Medical (M80)|Quick connect terminal 6.3 x 0.8 mm|D|7.8|-|1|0.47|55.4|4|350 g|ME|5|5500.2612.07| |10|Medical (M80)|Quick connect terminal 6.3 x 0.8 mm|D|4.5|-|1|0.47|23.6|4.7|625 g|MB|4|5500.2613.07| |12|Medical (M80)|Quick connect terminal 6.3 x 0.8 mm|D|3.25|-|1|0.47|16|4.6|630 g|MB|4|5500.2614.07| |16|Medical (M80)|Quick connect terminal 6.3 x 0.8 mm|D|2.8|-|1|0.47|10.9|5.6|826 g|MF|3|5500.2615.07| |25|Medical (M80)|Bolt and nut M4|D|2.0|-|2.2|0.47|4.8|6|830 g|MB|4|5500.2616.09| |36|Medical (M80)|Bolt and nut M4|D|1.23|-|2.2|0.47|3.3|8.5|810 g|MB|4|5500.2617.09| |1|Medical (M80)|Quick connect terminal 6.3 x 0.8 mm|F|22|0.49|0.33|0.47|1200|2.4|180 g|MC|10|5500.2620.07| |3|Medical (M80)|Quick connect terminal 6.3 x 0.8 mm|F|9.8|0.16|0.47|0.47|194|3.5|240 g|UB|10|5500.2621.07| |6|Medical (M80)|Quick connect terminal 6.3 x 0.8 mm|F|7.8|0.11|1|0.47|60|4.3|400 g|ME|5|5500.2622.07| |10|Medical (M80)|Quick connect terminal 6.3 x 0.8 mm|F|4.5|0.06|1|0.47|21|4.2|645 g|MB|4|5500.2623.07| |12|Medical (M80)|Quick connect terminal 6.3 x 0.8 mm|F|3.25|0.05|1|0.47|14.6|4.2|695 g|MB|4|5500.2624.07| |16|Medical (M80)|Quick connect terminal 6.3 x 0.8 mm|F|2.8|0.043|1|0.47|13.7|7|950 g|MF|3|5500.2625.07| **----- End of picture text -----**<br> Availability for all products can be searched real-time: https://www.schurter.com/en/info-center/support-tools/stock-check-distributors Designs C) High symmetrical and asymmetrical noise attenuation D) Excellent high frequency noise attenuation F) Excellent low frequency noise attenuation 25A and 36A medical filter M5 and M80, are only suitable for medical equipment intended for permanently connection to the mains. ## **Accessories** ## **Description** DIN_Rail_Kit Mounting accessory for compact 1- and 3-phase filters The specifications, descriptions and illustrations indicated in this document are based on current ~~information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications.~~ EMC Products **12**
Updated at June 10, 2026
SCHURTER is a globally recognized innovator and manufacturer of high-quality electronic components, specializing in products that ensure a safe and clean supply of power. With a strong reputation in the electronics and PCB assembly industries, the company delivers reliable solutions engineered to protect critical circuits, streamline device operation, and optimize electrical performance across diverse applications. The core of our SCHURTER portfolio revolves around comprehensive circuit protection. We carry an extensive selection of standard and resettable fuses, accompanied by robust fuse holders, to safeguard sensitive electronics against overcurrent conditions. Furthermore, our offering features high-performance thermal circuit breakers and associated accessories, providing dependable protection and rapid reset capabilities for demanding industrial and commercial environments. Beyond fundamental circuit protection, SCHURTER excels in electromagnetic compatibility (EMC) and RFI suppression technologies. Our range includes precision-engineered power line filters and common mode chokes designed to mitigate electromagnetic interference and ensure signal integrity. Accompanied by specialized components such as AC/DC LED power supplies, SCHURTER provides the meticulous engineering and durability necessary for modern, high-reliability electronic design.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →