526418
P.BE-CPX-AX-FR DESCRIPTION
- Manufacturer: FESTO
- Product type: Controller Accessories
- SVHC: No SVHC (25-Jun-2020)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 113.8 € |
| Current stock | 10+ |
| Lead time | 30 days |
# **Terminal CPX-P** Terminal CPX-P Key features ## **Key features** ## Installation concept - Economical from the smallest - configuration up to the maximum number of modules - Up to 9 electrical input/output modules plus bus node and pneumatic interface/electronics modules for valves - Extensive range of functions and connection options for the electrical modules - Choice of connection technology for technically and economically optimised connections - Can be used as a dedicated remote I/O module ## Electrics - High operating voltage tolerance (±25%) - Open to all fieldbus protocols and Ethernet - IT services and TCP/IP such as remote maintenance, remote diagnostics, web server, SMS and e-mail alert - Digital inputs and outputs, - 4-way/8-way/16-way, optionally available with individual channel diagnostics - Analogue inputs and outputs, 2-way/4-way - Analogue inputs and outputs with HART protocol - Input modules for connecting NAMUR sensors - Pressure inputs - Temperature inputs - IP65 or IP20 ## Mounting - Wall or H-rail mounting, also on mobile units - Conversions/extensions are possible at any time, individual linking - Modular system offering a range of configuration options - Fully assembled and tested unit - Reduced costs for selection, ordering, assembly and commissioning thanks to the central CPX-P terminal - Choice of pneumatic components for optimised control chain ## Operation - Fast troubleshooting thanks to an extensive selection of LEDs (some of which are multi-coloured) on the bus node and on all I/O modules - Suitable for direct machine mounting (IP65/IP67) or in a control cabinet with a terminal connection (IP20) - Supports module and channel-oriented diagnostics - Fieldbus/Ethernet remote diagnostics - Innovative diagnostic support with integrated web server/web monitor or Festo Maintenance Tool (CPX-FMT) with USB adapter (NEFC) for PC - Optimised commissioning thanks to parameterisable functions - Reliable servicing with connection blocks and modules that are quick to replace without changing the wiring 2 d **Internet: www.festo.com/catalogue/...** Subject to change – 2023/10 Terminal CPX-P ## Key features ## **Variants of the CPX-P terminal controller (with bus node, without preprocessing)** Bus node Different bus nodes are used for integration in the control systems of various manufacturers. The CPX-P terminal can therefore be operated on commonly used fieldbus systems: - PROFIBUS-DP - PROFINET - DeviceNet• - CANopen Integration in universal networks based on Ethernet opens up new possibilities. Faster data transmission, real-time capability and above all additional IT services such as file transfer, web server, as website integrated in the CPX-P terminal, text message/e-mail alerts, etc. open up a • EtherNet/IP wide range of synergies. • Modbus/TCP These include standardised and uni• PROFINET versal communication technology • EtherCAT across all areas, including operating level, management level and field level in the production environment, with protection to IP65. The following protocols are supported: - Modbus/TCP **==> picture [473 x 168] intentionally omitted <==** **----- Start of picture text -----**<br> Bus node Industrial Ethernet bus node<br>1 1<br>0 i 3 : Y<br>2 7 2<br>t a 7 gs ] . T<br>LES,<br>3<br>**----- End of picture text -----**<br> - [1] Higher-order controller (PLC) - [2] Fieldbus - Communication with the higher-order controller via fieldbus - No preprocessing - Fieldbus protocol dependent on CPX bus node used - More than 90 I/Os, depending on bus node used - [1] Higher-order controller (PLC) - [2] Industrial Ethernet - [3] IT services: - Web - Email - Data transmission - Connection to a higher-order controller directly via EtherNet/IP, Modbus/TCP, EtherCAT or PROFINET - No preprocessing - Monitoring via Ethernet and web applications - More than 300 I/Os ## - **Note** H- Every electrical interface can be combined with an appropriate number of I/O modules and/or pneumatic components, depending on its address capacity. Likewise, every pneumatic variant of the CPX-P terminal can be operated with every electrical interface variant. 2023/10 – Subject to change 3 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Key features **Variants of the CPX-P terminal controller (with preprocessing in the control block)** Control block The optional front end controllers CPXCEC enable simultaneous access via Ethernet, in parallel with a bus node, as well as autonomous preprocessing. **==> picture [122 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> With control block in stand-alone mode<br>**----- End of picture text -----**<br> Access via Modbus/TCP and EasyIP is Commissioning, programming, and dialso possible. agnostics using the Festo software tool FST with hardware configurator. **==> picture [124 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> With control block in Festo EasyIP mode<br>**----- End of picture text -----**<br> **==> picture [5 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>**----- End of picture text -----**<br> **==> picture [5 x 85] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>2<br>**----- End of picture text -----**<br> **==> picture [58 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> [1] CODESYS/FST<br>**----- End of picture text -----**<br> - Decentralised controller with direct machine mounting - Downloading programs via Ethernet (or via the programming interface) - Supports full expansion of all CPX peripherals - More than 300 I/Os Can be successfully used in the follow applications: - [1] Industrial Ethernet - [2] IT services: - Web – Email - Data transmission - Fast preprocessing of the CPX-P peripherals in the control block - Exchange of any data between the control blocks via EasyIP - Remote diagnostics - No higher-order controller is required - More than 300 I/Os per CPX-P control block - Stand-alone individual workstations - Interlinked, stand-alone sub-systems - Automation using IT technology Subject to change – 2023/10 d **Internet: www.festo.com/catalogue/...** 4 Terminal CPX-P ## Key features **Variants of the CPX-P terminal controller (with preprocessing in the control block)** With control block as remote controller on Ethernet **==> picture [370 x 250] intentionally omitted <==** **----- Start of picture text -----**<br> With control block as remote controller on the fieldbus<br>Fieldbus remote controller (combina- decentralised, stand-alone<br>tion with bus nodes for PROFIBUS DP, subsystems.<br>PROFINET, CANopen, DeviceNet or<br>EtherCAT) as the preprocessing unit for<br>1 1<br>2 2<br>LI LI 7 WA<br>3<br>3 4<br>**----- End of picture text -----**<br> Remote controller via Ethernet as the preprocessing unit for decentralised, stand-alone sub-systems using IT technology. - [1] Higher-order controller (PLC) - [2] Industrial Ethernet - [3] IT services: - Web - Email - Data transmission - Connection to a higher-order controller via Ethernet, no further bus node is required - Monitoring via Ethernet and web applications - Preprocessing of the CPX-P peripherals by CPX-P control block - More than 300 I/Os - [1] Higher-order controller (PLC) - [2] Fieldbus - [3] Industrial Ethernet - [4] IT services: - Web - Email - Data transmission - Fast preprocessing of the CPX-P peripherals in the control block - Communication with the higher-order controller via fieldbus - Optional additional monitoring via Ethernet and web applications - Downloading programs via programming interface - More than 300 I/Os, bus node is only used for communication with the higher-order PLC - Option of two bus nodes for redundant communication configuration 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 5 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Key features ## **Variants of the CPX-P terminal controller (with preprocessing in the control block)** With control block as CANopen fieldbus master **==> picture [214 x 196] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>2<br>3<br>4<br>**----- End of picture text -----**<br> - [1] Higher-order controller (PLC) - [2] Industrial Ethernet - [3] IT services: - Web - Email - Data transmission - [4] Fieldbus (CANopen) ## Features: - Connection to a higher-order controller via Ethernet, no further bus node is required - Monitoring via Ethernet - Preprocessing of the CPX-P peripherals by CPX-P control block - More than 300 I/Os - Up to 128 stations with repeater technology on CANopen ## Operating modes: - Remote controller on Ethernet - Control block in Festo EasyIP mode **==> picture [250 x 91] intentionally omitted <==** Subject to change – 2023/10 6 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Key features ## **Interface of inputs and outputs to the CPX-P terminal** Digital and analogue CPX-P I/O modules ## Electrical connection The connection technology for sensors and additional actuators offers a wide range of digital and analogue input and output modules and is freely selectable – as appropriate to your standard or the application. The input/output modules can be combined as required with the connection blocks: - M12, 5-pin - M12 5-pin, with quick lock and metal thread - M12, 8-pin - M8, 3-pin - M8, 4-pin - Sub-D 25-pin - CageClamp[®] (with cover also to IP65/67) - Screw terminal and spring-loaded terminal CPX modules for NAMUR sensors ## Electrical connection The electronics modules for NAMUR sensors can only be combined with certain connection blocks. The input modules can be combined as required with the connection blocks: - M12, 4-pin - Screw terminal and spring-loaded terminal CPX modules for NAMUR sensors, intrinsically safe circuits for ATEX applications **==> picture [230 x 305] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>7<br>‘a<br>Oo Oo<br>5<br>2<br>Ke<br>4<br>Q Ps A<br>G@ A it é G<br>6<br>ae<br>6 3<br>**----- End of picture text -----**<br> - [1] Higher-order controller (PLC) - [2] Non-ATEX zone; non-intrinsically safe circuits are permitted - [3] ATEX zone; only intrinsically safe circuits are permitted - [4] CPX input module for NAMUR sensors, non-intrinsically safe design - [5] CPX input module for NAMUR sensors, intrinsically safe design - [6] Actuator/machine component with NAMUR sensors - [7] Fieldbus - **Note** H- Intrinsically safe circuits are circuits which release so little energy during operation, or in the event of certain faults under specified test conditions, that no ignition can occur in a particular potentially explosive atmosphere. CPX-P modules are suitable for configuring intrinsically safe or non-intrinsically safe circuits, depending on the design selected. This enables components from both - safe and potentially explosive zones to be connected to the CPX-P terminal. The components for the intrinsically safe zone are marked in blue or entirely coloured blue to distinguish them visually. 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 7 Terminal CPX-P ## Key features ## **Interface of inputs and outputs to the CPX-P terminal** With CPX-CTEL interface - Up to 4 devices with individual Several CPX-P CTEL masters can be electronic protection per CPX-CTEL combined on one CPX-P terminal master (depending on the controller used). - • Max. 64 inputs/64 outputs per Combination of central CPX-P I/O I-Port interface modules and decentrally mounted I/O - • The maximum length of a string is modules with I-Port interface. 20 m. **==> picture [174 x 199] intentionally omitted <==** **----- Start of picture text -----**<br> |<br>All 72532<br>ne [ogy]<br>A S (| Va<br>. 1te Ce y<br>a<br>oe) 6<br>With CPX-CTEL-2 interface<br>3G 3G 3G 3G 5J 5J 5J 5J<br>12/14 82/84<br>11 3/5<br>1<br>**----- End of picture text -----**<br> - Input modules with 16 digital inputs (connection technology M8 3-pin and M12 5-pin) - Valve terminals with I-Port interface (up to 48 solenoid coils, different valve functions) - Up to 2 IO-Link devices with Several CPX-CTEL-2 interfaces can be individual electronic protection per combined on one CPX-P terminal CPX-CTEL-2 interface (depending on the controller used). - • Max. 16-byte inputs/16-byte Combination of central CPX-P I/O outputs per IO-Link device modules and decentrally mounted I/O - • The maximum length of a string is modules with IO-Link interface. 20 m. Subject to change – 2023/10 8 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Key features ## **Pneumatic variants of the CPX-P terminal** With valve terminal MPA-S – centralised **==> picture [189 x 171] intentionally omitted <==** The electrical terminal CPX-P is a modular peripheral system for valve terminals. The system is specifically designed so that the valve terminal can be adapted to suit different applications. The modular system design lets you configure the number of valves, inputs and additional outputs to suit the application. ## **Ordering** The CPX-P terminal with valve terminal is fully assembled according to your order specifications and individually tested. It consists of the electrical peripherals including the desired actuation and the selected components from the MPA-S modular system. The CPX-P terminal with valve terminal is ordered using two separate order codes. One order code defines the electrical peripherals type CPX-P, while the other specifies the pneumatic components of the valve terminal. The electrical peripherals type CPX-P can also be configured without a valve terminal and can be used on a fieldbus. To order this, only the order code for the electrical peripherals is required. The order lists for the pneumatic components can be found at a Internet: mpa-s (valve terminal MPA-S) 2023/10 – Subject to change 9 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Peripherals overview |||S|<br>oS<br>8<br>& e|| |---|---|---|---| |Designation<br>[1]<br>End plate|Type<br>Description<br>CPX-M-EPR-EV<br>CPX-M-EPL-EV<br>• Mounting holes for wall mounting<br>• Functional earth connection<br>• Special earthin|Description<br>• Mounting holes for wall mounting<br>• Functional earth connection<br>ecial earthing plate for safe and easyconnection to the machine bed or H-rail|aPage/Internet| |[2]<br>Bus node<br>Control block|CPX-FB<br>CPX-M-FB<br>• Fieldbus/Industrial Ethernet connection using various types of connection technology<br>• Setting fieldbus parameters via DIL switch<br>• Display|• Fieldbus/Industrial Ethernet connection using various types of connection technology<br>• Setting fieldbus parameters via DIL switch<br>yof fieldbus andperipheral equipment status via LED|| ||CPX-CEC<br>• Preprocessing, stand-alone controller or remote unit CPX-CEC<br>• Connection via Ethernet TCP/IP or Sub-D programming interface<br>• Setting operating modes via DIL switch and program selection via rotary switch<br>• CPX-CMX|• Preprocessing, stand-alone controller or remote unit CPX-CEC<br>• Connection via Ethernet TCP/IP or Sub-D programming interface<br>• Setting operating modes via DIL switch and program selection via rotary switch<br>• CPX-CMXproducts for controllingaxes|| |[3]<br>Interlinking block|CPX-M-GE<br>• Internal linking of the power supply and serial communication<br>• External power supply for the entire system or for outputs<br>• Connection accessories for 7/8"<br>• Individual linking with M6 screws, individually expandable|• Internal linking of the power supply and serial communication<br>• External power supply for the entire system or for outputs<br>• Connection accessories for 7/8"<br>• Individual linking with M6 screws, individually expandable|| Subject to change – 2023/10 10 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Peripherals overview **==> picture [523 x 544] intentionally omitted <==** **----- Start of picture text -----**<br> Designation Type Description a Page/Internet<br>[4] Electronics module CPX-4DE Input module with 4 digital inputs, positive logic (PNP)<br>CPX-8DE Input module with 8 digital inputs, positive logic (PNP)<br>CPX-8DE-D Input module with 8 digital inputs, positive logic (PNP), enhanced diagnostic function<br>CPX-8NDE Input module with 8 digital inputs, negative logic (NPN)<br>CPX-P-8DE-N NAMUR input module with 8 digital inputs<br>CPX-P-8DE-N-IS Input module to NAMUR standard with 8 digital inputs, intrinsically safe version<br>CPX-F8DE-P PROFIsafe input module with 8 digital inputs<br>CPX-16DE Input module with 16 digital inputs, internal electronic fuse per module<br>CPX-M-16DE-D Input module with 16 digital inputs, internal electronic fuse per channel pair, for CPX in<br>metal<br>CPX-4DA Output module with 4 digital outputs, 1 A per channel<br>CPX-8DA Output module with 8 digital outputs, 0.5 A per channel<br>CPX-8DA-H Output module with 8 digital outputs, 2.1 A per channel pair<br>CPX-8DE-8DA Input/output module with 8 digital inputs and 8 digital outputs<br>CPX-2ZE2DA Counter module with 2 digital inputs and 2 digital outputs<br>CPX-4AE-4AA-H HART input/output module with 4 analogue input/outputs<br>CPX-2AE-U-I Input module with 2 analogue current or voltage inputs<br>CPX-4AE-U-I Input module with 4 analogue current or voltage inputs<br>CPX-4AE-I Input module with 4 analogue current inputs<br>CPX-4AE-T Input module for temperature inputs<br>CPX-4AE-TC Input module for temperature inputs with cold junction compensation<br>CPX-2AA-U-I Output module with 2 analogue current or voltage outputs<br>CPX-FVDA-P2 PROFIsafe shut-off module for shutting off the supply voltage for valves, with two digital<br>outputs<br>[5] Plastic connection block CPX-AB • Choice of 8 connection technology variants –<br>• Degree of protection IP65, IP67 or IP20<br>• Can be combined with the electronics modules<br>• Connection accessories for M8/M12/Sub-D<br>• M8/M12/Sub-D, etc. connecting cables<br>• Modular system for M8/M12 connecting cables<br>[6] Analogue electronics module for pres- CPX-4AE-P • Pneumatic connection QS-4<br>sure inputs • Degree of protection IP65, IP67<br>• 4 analogue pressure inputs (0 ... 10 bar, –1 ... +1 bar)<br>[7] CTEL interface CPX-CTEL • Interfaces for decentralised installation systems, thus optimising the pneumatic con-<br>trol chains (short tubes/short cycle times)<br>• Actuation for I/O modules and valve terminals<br>• Power supply and bus interface via the same cable<br>• M9, M12 connection technology<br>• Degree of protection IP65, IP67<br>[8] Metal connection block CPX-M-AB • Can be combined with the electronics modules –<br>• Connection technology M12x1, 5-pin<br>• Degree of protection IP65, IP67<br>• Connection accessories for M12<br>• Connecting cables M12<br>• Modular system for choice of connecting cables M12<br>[9] Pneumatic interface MPA-S VMPA-FB • Control of valve terminal MPA-S<br>• Control of pressure sensors<br>• Control of proportional pressure regulators<br>[11] Web monitor – • Website integrated in the CPX terminal –<br>• Dynamic status indication<br>• Online diagnostics and SMS/e-mail alert<br>**----- End of picture text -----**<br> 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 11 Terminal CPX-P ## Peripherals overview ## **Individual overview of modules** Bus node ## Bus node for - PROFIBUS-DP - DeviceNet - CANopen - EtherNet/IP - PROFINET a Page 52 Control block a Page 45 ## CPX-CEC - Programming with CODESYS - Ethernet interface - Modbus/TCP - EasyIP - CANopen master - EtherCAT ## CTEL interface a Page 86 Electrical interface CPX-CTEL-2 ## Interface CPX-CTEL - CTEL master - Max. 4 devices with individual electronic protection - Max. 64 inputs/64 outputs per I-Port interface - The maximum length of a string is 20 m a Page 92 ## Interface CPX-CTEL-2 - Master for IO-Link - Max. 2 devices with individual electronic protection - Process data length of the inputs and outputs is limited to 16 bytes for inputs and 16 bytes for outputs per port - The maximum length of a string is 20 m ## Modules for controlling pneumatic drive units ## CPX-CMIX - Measuring module - CAN input (Festo specification) for measuring signal - Recording the absolute position values or speed values of the connected drive a Page 97 Plastic connection block Direct machine mounting (connection block to IP65/IP67) - M8, 3-pin **==> picture [73 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Metal connection block<br>**----- End of picture text -----**<br> Direct machine mounting (connection block to IP65/IP67) - M12, 5-pin - M8, 4-pin - M12, 5-pin - M12 5-pin quick lock, shielded with metal thread - M12, 8-pin - Sub-D 25-pin - Spring-loaded terminal with cover ## Protected fitting space (degree of protection IP20) - Spring-loaded terminal ## Shielding concept - Optional screening plate for connection block with M12 connection technology Subject to change – 2023/10 12 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Peripherals overview - **Individual overview of modules** Digital electronics module for inputs/ a Page 104 Analogue electronics module for a Page 139 outputs inputs/outputs Digital inputs Analogue inputs • 4 digital inputs• 8 digital inputs "ce, Ne • 2 analogue inputs (0 ... 10 V DC, 0 ... 20 mA, 4 ... 20 mA) • 16 digital inputs < • 4 analogue inputs (1 ... 5 V, 0 ... 10 V, –5 ... +5 V, –10 ... +10 V, - Zoe. Q E> Digital outputs i 0 ... 20 mA, 4 ... 20 mA, • 4 digital outputs (1 A per channel, ty –20 ... +20 mA) individual channel diagnostics) • 4 analogue inputs with HART - • 8 digital outputs (0.5 A per channel, protocol individual channel diagnostics) - • 8 digital outputs (2.1 A/50 W lamp Analogue temperature inputs load per channel pair, individual • 4 analogue inputs for temperature channel diagnostics) measurement (Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, - Multi I/O modules Ni500, Ni1000) • 8 digital inputs and 8 digital out• 4 analogue inputs for temperature puts measurement (thermocouple and - • 2 digital inputs (counter channels, PT1000 sensor for cold-junction connection to various encoders) and compensation) 2 digital outputs (directly controlled by the input values) Analogue outputs • 2 analogue outputs (0 ... 10 V DC, 0 ... 20 mA, 4 ... 20 mA) - • 4 analogue outputs with HART protocol - PROFIsafe input module a Page 115 PROFIsafe shut-off module a Page 158 =S\ Digital inputs Digital outputs • 8 digital inputs • 2 digital outputs • 11 function modes • Supply voltage for valves can be • 5 independent clock outputs shut off 2023/10 – Subject to change 13 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Peripherals overview ## **Individual overview of modules** Connection block for NAMUR sensors and HART input/output module Direct machine mounting (connection block to IP65) - M12, 4-pin ## Protected fitting space (connection block to IP20) Digital electronics module for NAMUR sensors a Page 100 ## Digital inputs - 8 digital inputs for NAMUR sensors or wired mechanical contacts - Intrinsically safe design with additional protective measures in the event of failure - Screw terminal - Spring-loaded terminal Metal interlinking block – Individual linking System linking - Different voltages for supplying the modules - Serial communication between the modules System supply - 7/8" 5-pin In addition to system linking, power supply for the - Electronics plus sensors (8 A) - Valves plus actuators (8 A) ## Additional supply In addition to system linking, power supply for the - Actuators (8 A per supply) a Page 163 ## Expandability - Can be expanded as required by up to 10 interlinking blocks ## - **Note** H- The 7/8" supply is subject to the following restrictions due to the available accessories: - 5-pin 8 A Pneumatic interface MPA-S ## Valve terminal - MPA1 (360 l/min) - MPA14 (550 l/min) ## a Page 169 ## End plate End plate - Left - Right (for use without valves) - MPA2 (700 l/min) - Up to 128 solenoid coils - Up to 16 modules can be configured Subject to change – 2023/10 d **Internet: www.festo.com/catalogue/...** 14 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Peripherals overview ## **General basic data and guidelines** **==> picture [114 x 267] intentionally omitted <==** Max. 11 modules in total: - One bus node and/or one control block - Up to 9 additional input/output modules - In addition a pneumatic interface – Always positioned as the last module on the right-hand side - 16 MPA modules can be configured - Address capacity max. 512 inputs and 512 outputs, - depending on bus node or control block - One interlinking block with system supply - Multiple interlinking blocks with additional supplies Always positioned to the right of the interlinking block with system supply - The connection blocks can be combined with the electronics modules for inputs/outputs, with restrictions ( a table below) - The electronics modules for inputs/ outputs can be combined with various interlinking blocks ## **Combinations of connection blocks and digital input modules** **==> picture [523 x 199] intentionally omitted <==** **----- Start of picture text -----**<br> Digital electronics modules<br>CPX-4DE CPX-8DE CPX-8DE-D CPX-8NDE CPX-F8DE-P CPX-16DE CPX-M-16DE-D<br>Connection blocks, plastic design<br>CPX-AB-8-M8-3POL h h h h – – –<br>CPX-AB-8-M8X2-4POL – – – – – h –<br>CPX-AB-4-M12x2-5POL h h h h – – –<br>CPX-AB-4-M12x2-5POL-R h h h h – – –<br>CPX-P-AB-4XM12-4POL – – – – – – –<br>CPX-P-AB-4XM12-4POL-8DE-N-IS – – – – – – –<br>CPX-AB-4-M12-8POL – – – – – – –<br>CPX-AB-8-KL-4POL h h h h h h –<br>CPX-P-AB-2XKL-8POL – – – – – – –<br>CPX-P-AB-2XKL-8POL-8DE-N-IS – – – – – – –<br>CPX-AB-1-SUB-BU-25POL h h h h – h –<br>Connection blocks, metal design<br>CPX-M-AB-4-M12X2-5POL h h h h h – –<br>CPX-M-AB-8-M12X2-5POL – – – – – – h<br>**----- End of picture text -----**<br> 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 15 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Peripherals overview **==> picture [524 x 423] intentionally omitted <==** **----- Start of picture text -----**<br> Combination of connection blocks and digital input modules for NAMUR sensors<br>Digital electronics modules<br>CPX-P-8DE-N CPX-P-8DE-N-IS<br>Connection blocks, plastic design<br>CPX-AB-8-M8-3POL – –<br>CPX-AB-8-M8X2-4POL – –<br>CPX-AB-4-M12x2-5POL – –<br>CPX-AB-4-M12x2-5POL-R – –<br>CPX-P-AB-4XM12-4POL h –<br>CPX-P-AB-4XM12-4POL-8DE-N-IS – h<br>CPX-AB-4-M12-8POL – –<br>CPX-AB-8-KL-4POL – –<br>CPX-P-AB-2XKL-8POL h –<br>CPX-P-AB-2XKL-8POL-8DE-N-IS – h<br>CPX-AB-1-SUB-BU-25POL – –<br>Connection blocks, metal design<br>CPX-M-AB-4-M12X2-5POL – –<br>CPX-M-AB-8-M12X2-5POL – –<br>Combinations of connection blocks and digital output modules or multi I/O modules<br>Digital electronics modules<br>CPX-4DA CPX-8DA CPX-8DA-H CPX-8DE-8DA CPX-2ZE2DA CPX-FVDA-P2<br>Connection blocks, plastic design<br>CPX-AB-8-M8-3POL h h – – – –<br>CPX-AB-8-M8X2-4POL h h h – – –<br>CPX-AB-4-M12x2-5POL h h – – – –<br>CPX-AB-4-M12x2-5POL-R h h h – – –<br>CPX-P-AB-4XM12-4POL – – – – – –<br>CPX-P-AB-4XM12-4POL-8DE-N-IS – – – – – –<br>CPX-AB-4-M12-8POL – – – h – –<br>CPX-AB-8-KL-4POL h h h h – h<br>CPX-P-AB-2XKL-8POL – – – – – –<br>CPX-P-AB-2XKL-8POL-8DE-N-IS – – – – – –<br>CPX-AB-1-SUB-BU-25POL h h h h – –<br>Connection blocks, metal design<br>CPX-M-AB-4-M12X2-5POL h h h – – h<br>CPX-M-AB-8-M12X2-5POL – – – – – –<br>**----- End of picture text -----**<br> Subject to change – 2023/10 16 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Peripherals overview ## **Combinations of connection blocks and analogue electronics modules for inputs/outputs** **==> picture [523 x 197] intentionally omitted <==** **----- Start of picture text -----**<br> Analogue electronics modules<br>CPX-4AE-4AA-H CPX-2AE-U-I CPX-4AE-U-I CPX-4AE-I CPX-2AA-U-I CPX-4AE-P CPX-4AE-T CPX-4AE-TC<br>Connection blocks, plastic design<br>CPX-AB-8-M8-3POL – – – – – – – –<br>CPX-AB-8-M8X2-4POL – – – – – – – –<br>CPX-AB-4-M12x2-5POL – h h h h – h h<br>CPX-AB-4-M12x2-5POL-R – h h h h – h h<br>CPX-P-AB-4XM12-4POL h – – – – – – –<br>CPX-P-AB-4XM12-4POL-8DE-N-IS – – – – – – – –<br>CPX-AB-4-M12-8POL – – – – – – – –<br>CPX-AB-8-KL-4POL – h h h h – h h<br>CPX-P-AB-2XKL-8POL h – – – – – – –<br>CPX-P-AB-2XKL-8POL-8DE-N-IS – – – – – – – –<br>CPX-AB-1-SUB-BU-25POL – h h h h – – –<br>Connection blocks, metal design<br>CPX-M-AB-4-M12X2-5POL – h h h h – h h<br>CPX-M-AB-8-M12X2-5POL – – – – – – – –<br>**----- End of picture text -----**<br> 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 17 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Key features – Electrical components **Electrical connection – Connection block with M8, 3-pin connection** CPX-AB-8-M8-3POL **==> picture [166 x 146] intentionally omitted <==** **----- Start of picture text -----**<br> 2<br>1<br>3<br>**----- End of picture text -----**<br> - Compact for pre-assembled individual connection - individual connection -H- **Note** - • 8 sockets Festo delivers pre-assembled M8/ • 3-pin design for connecting M12 connecting cables one channel per socket (NEBU modular system) on request: - Tailored to the application - Perfectly fitting - Easy to install |Combination of connection block and electrical connection technology|Combination of connection block and electrical connection technology|Combination of connection block and electrical connection technology||| |---|---|---|---|---| |Connection block<br>[1] CPX-AB-8-M8-3POL|Connection technology<br>Socket M8, 3-pin||Plug/connecting cable<br>[2] SEA-GS-M8|Selectable connection technology<br>Solder lugs| ||||[2] SEA-3GS-M8-S|Screw terminals| ||||[3] NEBU-...-M8G3<br>(modular system for choice of connecting<br>cables)|Socket, M8, 3-pin| |||||Socket, M8, 4-pin| |||||Socket, M12, 5-pin| |||||Open cable end| Subject to change – 2023/10 18 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Key features – Electrical components **==> picture [523 x 202] intentionally omitted <==** **----- Start of picture text -----**<br> Electrical connection – Connection block with M8, 4-pin connection<br>CPX-AB-8-M8X2-4POL<br>• Compact for pre-assembled individ-<br>ual connection<br>• 8 sockets<br>• 4-pin design for connection of<br>2 channels per socket<br>4<br>3<br>1<br>6<br>5<br>2<br>**----- End of picture text -----**<br> **==> picture [523 x 260] intentionally omitted <==** **----- Start of picture text -----**<br> Combination of connection block and electrical connection technology<br>Connection block Connection Plug/connecting cable Selectable connection Plug/connecting cable Selectable connection<br>technology technology technology<br>[1] CPX-AB-8-M8X2-4POL Socket, M8, [2] NEBU-...-M8G4 Socket, M8, 3-pin – –<br>4-pin (modular system for choice Socket M8, 4-pin – –<br>of connecting cables) Socket, M12, 5-pin – –<br>Open cable end – –<br>[3] NEDY-L2R1-V1-M8G3-N- 1x plug M8, 4-pin [6] SEA-GS-M8 Solder lugs<br>M8G4 to [6] SEA-3GS-M8-S Screw terminals<br>(T-adapter) 2x socket, M8, 3-pin [5] NEBU-...-M8G3 Socket, M8, 3-pin<br>(modular system for choice Socket, M8, 4-pin<br>of connecting cables) Socket, M12, 5-pin<br>Open cable end<br>[4] NEDY-... 2x socket, M8, 3-pin – –<br>(modular system for all types 2x socket, M8, 4-pin – –<br>of sensor/actuator 2x socket, M12, 5-pin – –<br>distributor) 2x socket, type A – –<br>2x socket, type B – –<br>2x socket, type C – –<br>2x socket, plug pattern H – –<br>2x socket, plug pattern ZB – –<br>2x socket, plug pattern ZC – –<br>– –<br>2x open cable end<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 19 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Key features – Electrical components ## **Electrical connection – Connection block with M12, 5-pin connection** CPX-AB-4-M12x2-5POL and CPX-AB-4-M12x2-5POL-R, plastic **==> picture [250 x 215] intentionally omitted <==** **----- Start of picture text -----**<br> A I<br>><br>SS<br>2<br>3<br>ala ba2 Cy O gBy |! SAP<br>NE os aE O 7,<br>1<br>4<br>‘Cas<br>5<br>MU<br>> 7<br>’ © 6<br>7<br>**----- End of picture text -----**<br> - Suitable for self-assembly and sturdy with 2 channels per connection - 4 sockets - 5-pin design per connection - Version ...-R with quick lock technology and metal thread for shielding - With two channels per connection, the corresponding input signals can be easily connected via a T-adapter and conventional cables with M8 connection. Subject to change – 2023/10 20 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Key features – Electrical components **==> picture [523 x 453] intentionally omitted <==** **----- Start of picture text -----**<br> Combination of connection block and electrical connection technology<br>Connection block Connection Plug/connecting cable Selectable connection Plug/connecting cable Selectable connection<br>technology technology technology<br>[1] Socket, M12, [2] SEA-GS-7 Screw terminals – –<br>CPX-AB-4-M12x2-5POL 5-pin [2] SEA-4GS-7-2.5 Screw terminals – –<br>CPX-AB-4-M12x2-5POL-R [2] SEA-GS-9 Screw terminals – –<br>[2] SEA-M12-5GS-PG7 Screw terminals – –<br>[2] SEA-GS-11-DUO Screw terminals, for two – –<br>cables<br>[2] SEA-5GS-11-DUO Screw terminals, for two – –<br>cables<br>[3] NEBU-...-M12G5 Socket, M8, 4-pin – –<br>(modular system for choice Socket, M12, 5-pin – –<br>of connecting cables) Open cable end – –<br>[4] NEDY-... 2x socket, M8, 3-pin – –<br>(modular system for all types 2x socket, M8, 4-pin – –<br>of sensor/actuator 2x socket, M12, 5-pin – –<br>distributor) 2x socket, type A – –<br>2x socket, type B – –<br>2x socket, type C – –<br>2x socket, plug pattern H – –<br>2x socket, plug pattern ZB – –<br>2x socket, plug pattern ZC – –<br>2x open cable end – –<br>[5] NEDY-L2R1-V1-M8G3-N- Plug, M12, 4-pin [6] SEA-GS-M8 Solder lugs<br>M12G4 to [6] SEA-3GS-M8-S Screw terminals<br>(T-adapter) 2x socket, M8, 3-pin [7] NEBU-...-M8G3 Socket, M8, 3-pin<br>(modular system for choice Socket, M8, 4-pin<br>of connecting cables) Socket, M12, 5-pin<br>Open cable end<br>[5] NEDY-L2R1-V1-M12G5-N- Plug, M12, 4-pin [6] SEA-GS-7 Screw terminals<br>M12G4 to [6] SEA-4GS-7-2.5 Screw terminals<br>(T-adapter) 2x socket, M12, 5-pin [6] SEA-GS-9 Screw terminals<br>[6] SEA-M12-5GS-PG7 Screw terminals<br>[6] SEA-GS-11-DUO Screw terminals, for two<br>cables<br>[6] SEA-5GS-11-DUO Screw terminals, for two<br>cables<br>[7] NEBU-...-M12G5 Socket, M8, 4-pin<br>(modular system for choice Socket, M12, 5-pin<br>of connecting cables) Open cable end<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 21 d **Internet: www.festo.com/catalogue/...** ## Terminal CPX-P ## Key features – Electrical components ## **Electrical connection – Connection block (metal design)** CPX-M-AB-4-M12X2-5POL with connection socket M12, 5-pin - Suitable for self-assembly and sturdy with 2 channels per connection - 4 sockets **==> picture [212 x 197] intentionally omitted <==** **----- Start of picture text -----**<br> 2<br>x ;<br>a) ~@ 3<br>Bw’<br>4<br>2 | . “es<br>1<br>5<br>6<br>7<br>**----- End of picture text -----**<br> - 5-pin design per connection - With two channels per connection, the corresponding input signals can be easily connected via a T-adapter and conventional cables with M8 connection. ## CPX-M-AB-8-M12X2-5POL with connection socket M12, 5-pin - Suitable for self-assembly and sturdy with 2 channels per connection - 8 sockets **==> picture [212 x 197] intentionally omitted <==** **----- Start of picture text -----**<br> 2<br>2 L<br>Gal | 3<br>@ —&<br>4<br>1<br>5<br>6<br>7<br>**----- End of picture text -----**<br> - 5-pin design per socket - With two channels per connection, the corresponding input signals can be easily connected via a T-adapter and conventional connecting cables with M8 connection. - **Note** H- Max. 4 T-adapters (NEDY) can be mounted on a connection block. Subject to change – 2023/10 22 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Key features – Electrical components **==> picture [523 x 454] intentionally omitted <==** **----- Start of picture text -----**<br> Combination of connection block and electrical connection technology<br>Connection block Connection Plug/connecting cable Connection technology Plug/connecting cable Connection technology<br>technology<br>[1] Socket, M12, [2] SEA-GS-7 Screw terminals – –<br>CPX-M-AB-4-M12X2-5POL 5-pin [2] SEA-4GS-7-2.5 Screw terminals – –<br>CPX-M-AB-8-M12X2-5POL [2] SEA-GS-9 Screw terminals – –<br>[2] SEA-M12-5GS-PG7 Screw terminals – –<br>[2] SEA-GS-11-DUO Screw terminals, for two – –<br>cables<br>[2] SEA-5GS-11-DUO Screw terminals, for two – –<br>cables<br>[3] NEBU-...-M12G5 Socket, M8, 4-pin – –<br>(modular system for choice of connecting Socket, M12, 5-pin – –<br>cables) Open cable end – –<br>[4] NEDY-... 2x socket, M8, 3-pin – –<br>(modular system for all types of sensor/ 2x socket, M8, 4-pin – –<br>actuator distributor) 2x socket, M12, 5-pin – –<br>2x socket, type A – –<br>2x socket, type B – –<br>2x socket, type C – –<br>2x socket, plug pattern H – –<br>2x socket, plug pattern ZB – –<br>2x socket, plug pattern ZC – –<br>2x open cable end – –<br>[5] NEDY-L2R1-V1-M8G3-N-M12G4 Plug M12, 4-pin [6] SEA-GS-M8 Solder lugs<br>(T-adapter) to [6] SEA-3GS-M8-S Screw terminals<br>2x socket, M8, 3-pin [7] NEBU-...-M8G3 Socket, M8, 3-pin<br>(modular system for choice of Socket, M8, 4-pin<br>connecting cables) Socket, M12, 5-pin<br>Open cable end<br>[5] NEDY-L2R1-V1-M12G5-N-M12G4 Plug M12, 4-pin [6] SEA-GS-7 Screw terminals<br>(T-adapter) to [6] SEA-4GS-7-2.5 Screw terminals<br>2x socket M12, 5-pin [6] SEA-GS-9 Screw terminals<br>[6] SEA-M12-5GS-PG7 Screw terminals<br>[6] SEA-GS-11-DUO Screw terminals, for two<br>cables<br>[6] SEA-5GS-11-DUO Screw terminals, for two<br>cables<br>[7] NEBU-...-M12G5 Socket, M8, 4-pin<br>(modular system for choice of Socket, M12, 5-pin<br>connecting cables) Open cable end<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 23 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Key features – Electrical components - **Electrical connection – Connection block with M12, 4-pin connection** CPX-P-AB-4XM12-4POL li o O 2 - we ON 1 - Suitable for self-assembly and sturdy - 4 sockets - 4-pin design per connection Combination of connection block and electrical connection technology **==> picture [496 x 53] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |Connection block|Connection technology|Plug/connecting cable|Selectable connection technology| |[1] CPX-P-AB-4XM12-4POL|Socket, M12, 4-pin|[2] SEA-GS-HAR-4POL|Insulation displacement connector| |[2] SEA-4GS-7-2.5|Screw terminal| |[2] SEA-GS-7|Screw terminal| |[2] SEA-GS-9|Screw terminal| **----- End of picture text -----**<br> **==> picture [500 x 316] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||| |---|---|---|---|---|---| |Electrical connection – Connection block with M12, 4-pin connection| |CPX-P-AB-4XM12-4POL-8DE-N-IS| |• Suitable for self-assembly and stur-| |O|dy with 2 channels per connection| |• 4 sockets| |• 4-pin design per connection| |• With two channels per connection,| |©|a|((R||| |the corresponding input signals can| |hn|XC| |be easily connected via a T-adapter.| |3| |1| |2|—|7?| |3|CS| |Combination of connection block and electrical connection technology| |Connection block|Connection|Plug/connecting cable|Selectable connection|Plug/connecting cable|Selectable connection| |technology|technology|technology| |[1] CPX-P-AB-4XM12-4POL-8DE-N-IS|Socket, M12,|[3] NECU-M-S-A12G4-IS|Plug, M12, 4-pin|–|–| |4-pin| |[3] NECU-S-M12G4-...-IS|Plug, M12, 4-pin|–|–| |[2] NEDU-M12D4-M12T4-IS|1x plug M12, 4-pin|[3] NECU-S-M12G4-...-IS|Plug, M12, 4-pin| |(T-adapter)|to| |2x socket M12, 4-pin| **----- End of picture text -----**<br> Subject to change – 2023/10 24 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Key features – Electrical components **==> picture [523 x 151] intentionally omitted <==** **----- Start of picture text -----**<br> Electrical connection – Connection block with M12, 8-pin connection<br>CPX-AB-4-M12-8POL<br>• Connection to cylinder/valve<br>combinations with max. 3 inputs<br>and 2 outputs<br>• 4 sockets<br>• 8-pin design per socket<br>2<br>1<br>**----- End of picture text -----**<br> |1|1|1|1|1| |---|---|---|---|---| |Combination of connection block and electrical connection technology||||| |Connection block<br>[1] CPX-AB-4-M12-8POL|Connection technology<br>Socket, M12, 8-pin||Plug/connecting cable<br>[2] KM12-8GD8GS-2-PU (pre-assembled con-<br>necting cable)|Selectable connection technology<br>Socket, M12, 8-pin| **Electrical connection – Connection block with spring-loaded terminal connection** CPX-AB-8-KL-4POL 1 2 - Quick connection technology for use • Optional cover with fittings for in control cabinets IP65/67 connection - • 32 spring-loaded terminals – 8 through-holes M9 • 4 spring-loaded terminals per – 1 through-hole M16 channel – Blanking plug - • Wire cross-sections 0.05 ... 1.5 mm[2] – For I/O distributors, control desks or individual sensors/actuators |Combination of connection block and electrical connection technology|Combination of connection block and electrical connection technology|Combination of connection block and electrical connection technology|Combination of connection block and electrical connection technology|Combination of connection block and electrical connection technology| |---|---|---|---|---| |Connection block<br>[1] CPX-AB-8-KL-4POL|Connection technology<br>Spring-loaded terminals, 32-pin||Plug/connecting cable<br>[2] AK-8KL (cover)|Selectable connection technology<br>–| 2023/10 – Subject to change 25 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Key features – Electrical components **Electrical connection – Connection block with clamping connector** CPX-P-AB-2XKL-8POL and CPX-P-AB-2XKL-8POL-8DE-N-IS - Quick connection technology for use in control cabinets **==> picture [377 x 143] intentionally omitted <==** **----- Start of picture text -----**<br> in control cabinets<br>• Spring-loaded terminals or screw<br>terminals<br>• Wire cross sections 0.2 ... 2.5 mm<br>2<br>1<br>3<br>**----- End of picture text -----**<br> - Wire cross sections 0.2 ... 2.5 mm[2] |3|3|3||| |---|---|---|---|---| |Combination of connection block and electrical connection technology||||| |Connection block<br>[1] CPX-P-AB-2XKL-8POL|Connection technology<br>Plug, 8-pin||Plug/connecting cable<br>[2] NECU-L3G8-C1|Selectable connection technology<br>Spring-loaded terminals| ||||[3] NECU-L3G8-C2|Screw terminals| |[1] CPX-P-AB-2XKL-8POL-8DE-N-IS|<br>Plug, 8-pin||[2] NECU-L3G8-C1-IS|Spring-loaded terminals| ||||[3] NECU-L3G8-C2-IS|Screw terminals| **Electrical connection – Connection block with Sub-D connection** CPX-AB-1-SUB-BU-25POL **==> picture [122 x 134] intentionally omitted <==** **----- Start of picture text -----**<br> 2<br>1<br>**----- End of picture text -----**<br> - Multi-pin connection for I/O distributor or control desk - One Sub-D socket - 25-pin design |Combination of connection block and electrical connection technology|Combination of connection block and electrical connection technology|Combination of connection block and electrical connection technology|Combination of connection block and electrical connection technology|Combination of connection block and electrical connection technology| |---|---|---|---|---| |Connection block<br>[1] CPX-AB-1-SUB-BU-25POL|Connection technology<br>Sub-D socket, 25-pin||Plug/connecting cable<br>[2] SD-SUB-D-ST25|Selectable connection technology<br>Crimp contacts| Subject to change – 2023/10 26 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Key features – Mounting ## **Hood** Description **==> picture [250 x 209] intentionally omitted <==** The CPX hood CAFC is a space- and cost-saving alternative to a control cabinet. It is designed as an extruded aluminium profile and is installed on a mounting plate. The valve terminal is well protected and is quick to install without the need for a complex cabinet through-feed for cables and tubing. a 175 The rail and the two mounting brackets are mounted on a base plate. The hood is attached to the retaining rail and secured with two screws. There is also a stand-by position (detent of the hood in the open position). The hood is locked using two side screws (which meet the requirements for a special fastener in compliance with ATEX). The CPX hood can be ordered online using the valve terminal configurator. ## Advantages of the CPX hood - Impact protection (min. 7 J) for the modules underneath in combination with a suitable mounting plate provided by the user - Protection against electrostatic discharge by using electrically conductive materials and the option of connecting an earth wire - Protection against disconnection of live plugs (by securing the hood with at least one special fastener to EN 60079-0, 9.2 and 20) - UV protection for the CPX-P and MPA modules underneath - **Note** H- The CPX hood has no influence on the ATEX classification of the valve terminal or of the CPX-P terminal. ## Points to note when using the CPX hood - CPX-P power supply via angled • No MPA vertical stacking plugs, no T-plugs - plugs, no T-plugs • Use of larger push-in fittings (for - • Electrical supply plate/additional tubing O.D. larger than 12 mm) only supply only possible with angled possible with the angled design plug • Ducted exhaust air only with elbow - Ducted exhaust air only with elbow connector - The permissible ambient temperature range of the valve terminal is reduced by 5°C. The CPX hood has no influence on The CPX hood does not protect the IP protection class of the valve against the effects of the weather in terminal or of the CPX-P terminal. installations that are not in enclosed spaces. 2023/10 – Subject to change 27 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Key features – Mounting ## **Hood** Mounting Procedure: **==> picture [358 x 268] intentionally omitted <==** **----- Start of picture text -----**<br> 4<br>3<br>2<br>1<br>5<br>6<br>**----- End of picture text -----**<br> **==> picture [153 x 98] intentionally omitted <==** **----- Start of picture text -----**<br> 5<br>**----- End of picture text -----**<br> - Assemble the rail and mounting bracket included in the mounting kit - Attach the earthing cable - Assemble the hood (if applicable, screw together several hood sections and attach the side covers) - Attach and secure the hood - [1] Side cover - [2] Earthing cable - [3] Hood section - [4] Slot nut with screws, for joining the hood sections - [5] Rail - [6] Mounting bracket ## Technical data Weight: - Weight: • Mounting rail: approx. 550 g per • Hood: approx. 500 g per 100 mm of 1000 mm of length length • Side pieces: approx. 500 g per side - Side pieces: approx. 500 g per side - Ambient temperature –5 ... +50°C - RoHS-compliant ## **Plug coding** **==> picture [103 x 159] intentionally omitted <==** The connection blocks CPX-P-AB-2XKL-8POL and CPX-P-AB-2XKL-8POL-8DE-N-IS, and the sockets NECU-L3G8, can be matched to one another using the coding elements CPX-P-KDS-AB-2XKL. This reduces the possibility of the socket being plugged back into an incorrect slot after being disconnected from the CPX-P terminal (connection safeguard). Subject to change – 2023/10 28 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Key features – Mounting ## **Mounting options** The valve terminals with CPX-P terminal support different mounting options for direct machine mounting with a high degree of protection and for control cabinet installation. ## H-rail mounting The H-rail mounting is part of the rear profile of the CPX-P interlinking blocks. A The CPX-P terminal can be attached to the H-rail using the H-rail mounting kit. The CPX-P terminal is mounted on the H-rail (see arrow A) and B then swivelled onto the H-rail and secured in place with the clamping element (see arrow B). The optional earthing plate enables a connection to be established to the machine potential/earth in one easy step. The following mounting kit is needed for H-rail mounting: • CPX-CPA-BG-NRH This allows the CPX-P terminal to be mounted to the H-rails to EN 60715. An additional mounting kit may be required for combination with valve terminals. **==> picture [46 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Wall mounting<br>**----- End of picture text -----**<br> The end plates of the CPX-P terminal, the valve terminal and the pneumatic interface include mounting holes for wall mounting. Additional mountings for the CPX-P terminal are available for longer valve terminals. ## Additional mountings Additional mounting brackets for the CPX-P terminal that can be screwed -H- **Note** onto the interlinking blocks are availaFor CPX-P terminals with 4 or more ble for longer valve terminals. interlinking blocks: you need additional mounting brackets of type CPX-M-BG-RW approx. every 100 or 150 mm. These are supplied pre-assembled. **==> picture [62 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Linking with screws<br>**----- End of picture text -----**<br> The CPX-P modules are mechanically connected using an angled fitting. The CPX-P terminal can thus be expanded at any time. 2023/10 – Subject to change 29 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Key features – Power supply ## **Power supply concept** General **==> picture [447 x 148] intentionally omitted <==** **==> picture [253 x 97] intentionally omitted <==** The use of decentralised devices on the fieldbus – particularly with a high degree of protection for direct machine mounting – demands a flexible power supply concept. A valve terminal with CPX-P is, in principle, supplied with all A distinction is made between supply Connection technology: voltages via a single connection. for • 7/8" • Electronics plus sensors • Valves plus actuators Interlinking blocks Interlinking blocks represent the backbone of the CPX-P terminal with all supply lines. They provide the power supply for the modules used on them as well as their bus connections. Many applications require the CPX-P terminal to be segmented into voltage zones. This applies in particular to the separate disconnection of the outputs. The interlinking blocks provide either an easy-to-install central power supply for the entire CPX-P terminal or galvanically isolated, all-pin disconnectable potential groups/voltage segments. Subject to change – 2023/10 30 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Key features – Power supply ## **Interlinking blocks** With system supply - CPX-M-GE-EV-S-7/8-5POL - CPX-M-GE-EV-S-7/8-5POL-VL - Connection technology • 7/8" 5-pin - For CPX-P terminal modules and • For actuators that are connected to connected sensors output modules of the CPX-P - • For valves that are connected to the terminal CPX-P terminal via a pneumatic interface Without power supply - CPX-M-GE-EV - CPX-M-GE-EV-FVO With additional supply for outputs - CPX-M-GE-EV-Z-7/8-5POL • For actuators that are connected to • CPX-M-GE-EV-Z-7/8-5POL-VL output modules of the CPX-P terminal Connection technology - 7/8" 5-pin ## - **Note** H- For 7/8": - Commercially available accessories are often limited to max. 8 A ## - **Note** H- The valve terminal MPA-S has either voltage monitoring in the following a 7/8" 5-pin, 7/8" 4-pin or M18 MPA module. 3-pin power supply for one or more valve voltage zones. Galvanically isolated, all-pin disconnectable with 2023/10 – Subject to change 31 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Key features – Diagnostics ## **Diagnostics** System performance **==> picture [250 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> 3 4<br>2 5 6<br>1<br>**----- End of picture text -----**<br> The CPX-P terminal supports on-thespot diagnostics via a row of LEDs. This is separate from the connection area and therefore provides good visual access to status and diagnostic information. Detailed diagnostic functions are needed in order to quickly locate the causes of errors in the electrical installation and therefore reduce downtimes in production plants. A basic distinction is made between on-the-spot diagnostics using LEDs or PC and diagnostics using a bus interface. - [1] Undervoltage monitoring - [2] Diagnostics via bus interface - [3] Diagnostic overview LED - Fieldbus status - CPX-P status Module and channel-specific diagnostics are supported, for example: - Undervoltage detection for outputs and valves - Short circuit detection for sensors, outputs and valves - Open-load detection for a missing solenoid coil - Storage of the last 40 causes of errors with error start and error end - [4] Status and diagnostic LED for module and I/O channels - [5] Module and channel-specific diagnostics - [6] Valve-specific diagnostic module and solenoid coils The diagnostic messages can be read out via the bus interface in the higher-order controller and visualised for the central recording and evaluation of error causes. This is done using the individual fieldbus-specific channels. The CPX-CEC also offers the option of access via the integrated Ethernet interface (remote maintenance via PC/web applications). Overview of LEDs on the bus node **==> picture [38 x 52] intentionally omitted <==** **----- Start of picture text -----**<br> 1 2<br>**----- End of picture text -----**<br> ## [1] Fieldbus-specific LEDs On each bus node, a maximum of 4 fieldbus-specific LEDs display the fieldbus communication status of the CPX-P terminal with the higher-order controller. - [2] CPX-P-specific LEDs - A further 4 CPX-P-specific LEDs provide non-fieldbus-specific information about the status of the - CPX-P terminal, for example - Power system - Power load - System fault - Modify parameters Input/output module status and diagnostic LEDs ~~1 2 3~~ [1] Status LEDs for the inputs and outputs Each input and output channel is assigned a status LED. - [2] Channel-oriented diagnostic LEDs [3] Group diagnostic LEDs Depending on the module design, An LED displays the group another diagnostic LED is diagnostics for each module available for each I/O channel Subject to change – 2023/10 32 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Key features – Parameterisation ## **Diagnostics** Display on a PC **==> picture [135 x 101] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>3<br>EEX<br>\ LZ_<br>«a Ss<br>2 EEEEES <><br>**----- End of picture text -----**<br> - [1] CPX-P terminal with valve terminal - [2] Adapter diagnostic interface to USB - [3] Laptop/portable device with USB interface and installed CPX-P Maintenance Tool (CPX-FMT) software - Fault location and type - Without programming - Storing the configuration - Preparing screenshots ## **Parameterisation** Changes to the application are often consequently, the amount of storage required during commissioning. The space required. parameterisable characteristics of the It is therefore possible, for example, to CPX-P modules mean that functions reduce the input debounce time for an can be very easily changed by using input module – normally 3 ms – to configuration software. This reduces 0.1 ms on a "fast" input module for the number of modules needed and, faster processes, or to set the response of a valve following a fieldbus interruption. Depending on the modules used, parameterisation can be performed via the following interfaces: - Ethernet - Fieldbus - Control block direct interface (programming interface) **==> picture [173 x 35] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>=<br>2<br>**----- End of picture text -----**<br> [1] Input debounce time 3 ms - [2] Input debounce time 0.1 ms 2023/10 – Subject to change 33 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Key features – Addressing ## **Addressing** The various CPX-P modules occupy a Maximum system configuration: The maximum system configuration different number of I/O addresses • 1 bus node or control block can be limited in individual cases by -H- **Note** within the CPX-P system. The maximum • 9 I/O modules exceeding the address space. Please refer to the detailed descripaddress space for bus nodes depends • 1 pneumatic interface (e.g. pneution of the configuration/addressing on the performance of the fieldbus matic interface MPA-S with up to rules in the technical data for CPX-P systems. 16 MPA connection blocks) bus nodes. ## **Overview – Allocated addresses for CPX-P modules** **==> picture [524 x 470] intentionally omitted <==** **----- Start of picture text -----**<br> Inputs [bit] Outputs [bit]<br>CPX-CTEL-4-M12-5POL 0, 64, 128, 192, 256 [1)] 0, 64, 128, 192, 256 [1)]<br>CPX-CTEL-2-M12-5POL-LK 64, 128, 192, 256 [1)] 64, 128, 192, 256 [1)]<br>CPX-CMIX-M1-1 48 48<br>CPX-4DE 4 –<br>CPX-8DE 8 –<br>CPX-8DE-D 8 –<br>CPX-8NDE 8 –<br>CPX-P-8DE-N 16 8<br>CPX-P-8DE-N 80 16<br>(inputs configured as counter)<br>CPX-P-8DE-N-IS 16 8<br>CPX-P-8DE-N-IS 80 16<br>(inputs configured as counter)<br>CPX-F8DE-P 48 56<br>CPX-16DE 16 –<br>CPX-M-16DE-D 16 –<br>CPX-4DA – 4<br>CPX-8DA – 8<br>CPX-8DA-H – 8<br>CPX-8DE-8DA 8 8<br>CPX-2ZE2DA 96 96<br>CPX-4AE-4AA-H 0, 16, 32, 48, 64, 128, 144, 160, 176, 192 [1)] 0, 16, 32, 48, 64 [1)]<br>CPX-2AE-U-I 2 x 16 –<br>CPX-4AE-U-I 4 x 16 –<br>CPX-4AE-I 4 x 16 –<br>CPX-4AE-P-B2 4 x 16 –<br>CPX-4AE-P-D10 4 x 16 –<br>CPX-4AE-T 4 x 16 –<br>CPX-4AE-TC 4 x 16 –<br>CPX-2AA-U-I – 2 x 16<br>CPX-FVDA-P2 48 48<br>VMPA1-FB-EMS-8 – 8<br>VMPA1-FB-EMG-8 – 8<br>VMPA2-FB-EMS-4 – 4<br>VMPA2-FB-EMG-4 – 4<br>VMPA1-FB-EMS-D2-8 – 8<br>VMPA1-FB-EMG-D2-8 – 8<br>VMPA2-FB-EMS-D2-4 – 4<br>VMPA2-FB-EMG-D2-4 – 4<br>VMPA-FB-PS-1 16 –<br>VMPA-FB-PS-3/5 16 –<br>VMPA-FB-PS-P1 16 –<br>VMPA-FB-EMG-P1 16 16<br>**----- End of picture text -----**<br> - 1) Dependent on the DIL switch setting on the module Subject to change – 2023/10 34 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Key features – Addressing ## **Overview – Address space for CPX-P bus node and control block** **==> picture [523 x 153] intentionally omitted <==** **----- Start of picture text -----**<br> Protocol Max. total Max. digital Max. analogue<br>Inputs Outputs Inputs Outputs Inputs Outputs<br>CPX-CEC • CODESYS Level 2 512 bits 512 bits 512 DI 512 DO 32 AI 18 AO<br>• TCP/IP<br>• Easy IP<br>• Modbus TCP<br>CPX-FB11 DeviceNet 512 bits 512 bits 512 DI 512 DO 32 AI 18 AO<br>CPX-FB13 PROFIBUS 512 bits 512 bits 512 DI 512 DO 32 AI 18 AO<br>CPX-FB14 CANopen 256 bits 256 bits 64 DI (+ 64 DI) 64 DO (+ 64 DO) 8 AI (+ 8 AI) 8 AO (+ 8 AO)<br>CPX-FB36 EtherNet/IP 512 bits 512 bits 512 DI 512 DO 32 AI 18 AO<br>CPX-FB37 EtherCAT 512 bits 512 bits 512 DI 512 DO 32 AI 18 AO<br>CPX-FB43 PROFINET RT 512 bits 512 bits 512 DI 512 DO 32 AI 18 AO<br>CPX-M-FB44 PROFINET RT 512 bits 512 bits 512 DI 512 DO 32 AI 18 AO<br>CPX-M-FB45 PROFINET RT 512 bits 512 bits 512 DI 512 DO 32 AI 18 AO<br>**----- End of picture text -----**<br> ## - **Note** H- The bandwidth of the bus nodes can be restricted by the choice of module and the maximum number of modules. 2023/10 – Subject to change 35 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet -KModule width 50 mm - **Note** H- The data shown here apply to the CPX-P system. If components with lower values are used in the system, the specification for the entire system is reduced to the values of those components. ## **Example** Degree of protection IP65 applies only to the fully assembled system with fitted plugs or covers (which must also conform to IP65). If components with a lower degree of protection are used, the protection level of the entire system is reduced to the degree of protection of the component with the lowest degree of protection, for example CageClamp connection block with degree of protection IP20. ## **General technical data** |**General technical data**<br>Module no.<br>562818<br>Max. number of modules1)<br>Control block<br>1<br>Bus node<br>1<br>I/O modules<br>9<br>Pneumatic interface<br>1|**General technical data**<br>Module no.<br>562818<br>Max. number of modules1)<br>Control block<br>1<br>Bus node<br>1<br>I/O modules<br>9<br>Pneumatic interface<br>1| |---|---| ||1| ||9| ||1| |Max. address capacity<br>Inputs<br>[byte]<br>Outputs<br>[byte]|64| ||64| |Internal cycle time<br>[ms]|<1| |Configuration support|Fieldbus-specific| |LED displays<br>Bus node/control block<br>I/O modules<br>Pneumatic interface|Up to 4 LEDs, bus-specific<br>4 LEDs, CPX-P-specific<br>• PS = Power system<br>• PL = Power load<br>• SF = System fault<br>• M = Modify parameter/forcingactive| ||Min. one group diagnostic LED<br>Channel-oriented status and diagnostic LED, dependingon module| ||One group diagnostics LED<br>Valve status LED on valve| |Diagnostics|• Channel and module-oriented diagnostics for inputs/outputs and valves<br>• Detection of module undervoltage for the different potential values<br>• Storage of the last 40 errors with timestamp (acyclic access)| - 1) A maximum of 11 modules in total can be combined. - (e.g. 1 control block + 9 I/O modules + 1 pneumatic interface, or 1 control block + 1 bus node + 8 I/O modules + 1 pneumatic interface) Subject to change – 2023/10 36 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet ## **General technical data** **==> picture [523 x 376] intentionally omitted <==** **----- Start of picture text -----**<br> Module no. 562818<br>Parameterisation Module-specific and entire system, for example:<br>• Diagnostic behaviour<br>• Condition monitoring<br>• Profile of inputs<br>• Fail-safe response of outputs and valves<br>Commissioning support Forcing of inputs and outputs<br>Nominal operating voltage [V DC] 24<br>Operating voltage range [V DC] 18 ... 30<br>Power supply Interlinking block with system supply<br>Electronics plus sensors [A] 8<br>Actuators plus valves [A] 8<br>Additional supply<br>Actuators [A] 8<br>Current consumption Depending on system configuration<br>Mains buffering (bus electronics only) [ms] 10<br>Power supply connection 7/8" 5-pin<br>Fuse concept Per module with electronic fuses<br>Tests Vibration test to DIN IEC 68 • With wall mounting: Severity level 2<br>• With H-rail mounting: Severity level 1<br>Shock test to DIN IEC 68 • With wall mounting: Severity level 2<br>• With H-rail mounting: Severity level 1<br>Immunity to interference EN 61000-6-2 (industry)<br>Interference emission EN 61000-6-4 (industry)<br>Isolation test for galvanically isolated circuits to IEC 1131 Part 2 [V DC] 500<br>Galvanic isolation of electrical voltages [V DC] 80<br>Protection against direct and indirect contact PELV<br>Materials End plates: Die-cast aluminium<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Operating and environmental conditions<br>Module no. 562818<br>Ambient temperature [°C] –5 ... +50<br>Storage temperature [°C] –20 ... +70<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 37 d **Internet: www.festo.com/catalogue/...** Terminal CPX **==> picture [596 x 40] intentionally omitted <==** ## Data sheet ## **Certifications and approvals – Maximum values** **==> picture [524 x 198] intentionally omitted <==** **----- Start of picture text -----**<br> Module no. 562818<br>ATEX category gas II 3G<br>Type of ignition protection for gas Ex nA IIC T4 Gc<br>Explosion-proof ambient temperature [°C] –5 ≤ Ta ≤ +50<br>CE marking (see declaration of conformity) [1)] To EU Explosion Protection Directive (ATEX)<br>To EU EMC Directive [2)]<br>To EU Machinery Directive<br>To EU RoHS Directive<br>UKCA marking (see declaration of conformity) [1)] To UK EX instructions<br>To UK instructions for EMC<br>To UK instructions for machines<br>To UK RoHS instructions<br>KC mark KC EMC<br>Degree of protection to EN 60529 IP20, IP65<br>Certification c UL us - Recognized (OL)<br>RCM mark<br>Explosion protection certification outside the EU EPL Gc (BR)<br>Certificate issuing authority DNV 15.0193 X<br>**----- End of picture text -----**<br> - 1) More information: www.festo.com/catalogue/... d Support/Downloads. 2) For information about the area of use, see the EC declaration of conformity at: www.festo.com/catalogue/... d Support/Downloads. If the devices are subject to usage restrictions in residential, commercial or light-industrial environments, further measures for the reduction of the emitted interference may be necessary. - **Note** H- The values indicated represent the Depending on the individual You can select e.g. the individual a Internet: cpx-p maximum performance limits that components used, the value actually components required to achieve the can be achieved with the fully achieved for the overall product may ATEX category by choosing the assembled product. be lower. corresponding features in the online product configurator: Subject to change – 2023/10 38 d **Internet: www.festo.com/catalogue/...** Terminal CPX **==> picture [596 x 40] intentionally omitted <==** ## Data sheet **==> picture [523 x 429] intentionally omitted <==** **----- Start of picture text -----**<br> Weights [g]<br>Control block CEC...V3 135 PROFIsafe Shut-off module 50<br>Bus node FB11 120 Input module 46<br>FB13 115 Counter module 2ZE2DA 130<br>FB14 115 CTEL interface CTEL 110<br>– – Electrical interface CTEL-2 110<br>– – Axis interface CM-HPP 140<br>– – Measuring module CMIX 140<br>FB36 125 Plastic connection block 8-way, M8 3-pin 62<br>FB37 125 8-way, M8 4-pin 65<br>FB43 185 4-way, M12 5-pin 60<br>FB44 280 4-way, M12 5-pin, quick lock, shielded with 87<br>FB45 280 metal thread<br>I/O module 4 digital outputs 42 4-way, M12 8-pin 65<br>4 digital inputs 39 Spring-loaded terminal, 32-pin 75<br>8 digital inputs 39 Sub-D 25-pin 72<br>8 digital inputs, positive logic (PNP), enhanced 45 8-way, DIL switch 57<br>diagnostic function<br>8 digital inputs, negative logic (NPN) 40 Connection block for NAMUR 4-way, M12 4-pin 120<br>8 digital inputs to NAMUR 100 and HART module Clamping connector 8-pin 100<br>16 digital inputs, internal electronic fuse per 41 Metal connection block 4-way, M12 5-pin 112<br>module 4-way, M12 5-pin, pulsed sensor supply 110<br>16 digital inputs, internal electronic fuse per 46 8-way, M12 5-pin 152<br>channel pair, for CPX in metal Interlinking block, metal Without power supply 169<br>8 digital inputs, 8 digital outputs 48 System supply, 7/8" 5-pin 187<br>8 digital outputs, power supply 0.5 A per 49 Tie rods 1-way 41<br>channel 2-way 71<br>8 digital outputs, power supply 2.1 A per 48 3-way 97<br>channel pair 4-way 127<br>2 analogue current or voltage inputs 48 5-way 156<br>6-way 173<br>4 analogue current inputs 47 7-way 199<br>2 analogue current or voltage outputs 49 8-way 247<br>9-way 274<br>4 analogue inputs/outputs, HART 77.4 10-way 301<br>2 or 4 analogue temperature inputs 47 End plate for metal design Left-hand 113<br>4 analogue temperature inputs, with 2-wire 46 Right-hand 113<br>connection for a PT1000 sensor for cold End plate with extension Left-hand 190<br>junction compensation Right-hand 175<br>4 analogue pressure inputs 115 Pneumatic interface MPA-S 238.4<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 39 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet **==> picture [524 x 494] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data – Accessories<br>Designation Part no. Type<br>Mounting<br>Attachment for wall mounting (for long valve terminals, 2 mounting brackets and 4 screws) 550217 CPX-M-BG-RW-2x<br>Mounting for H-rail 526032 CPX-CPA-BG-NRH<br>Interlinking block<br>Without power supply – 550206 CPX-M-GE-EV<br>With system supply 7/8" connection, 5-pin – 550208 CPX-M-GE-EV-S-7/8-5POL<br>For ATEX environment 8022165 CPX-M-GE-EV-S-7/8-5POL-VL<br>With additional supply for 7/8" connection, 5-pin – 550210 CPX-M-GE-EV-Z-7/8-5POL<br>outputs<br>For ATEX environment 8022158 CPX-M-GE-EV-Z-7/8-5POL-VL<br>Mounting accessories<br>Screws for mounting the bus node/connection block on an Bus node/plastic connection block 550219 CPX-M-M3x22-4x<br>interlinking block<br>Bus node/metal connection block 550216 CPX-M-M3x22-S-4x<br>End plates<br>End plate Right-hand 550214 CPX-M-EPR-EV<br>Left-hand 550212 CPX-M-EPL-EV<br>Power supply<br>Plug socket for mains connection 7/8", straight, 5-pin 0.25 ... 2.0 mm [2] 543107 NECU-G78G5-C2<br>Plug socket for mains connection 7/8", angled, 5-pin – open cable end, 5-pin 2 m 573855 NEBU-G78W5-K-2-N-LE5<br>Inscription labels<br>Inscription labels 6x10 mm, 64 pieces, in frame 18576 IBS-6x10<br>**----- End of picture text -----**<br> Subject to change – 2023/10 40 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet **==> picture [523 x 267] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data – Accessories<br>Designation Part no. Type<br>Hood<br>Mounting rail for attaching the hood 1000 mm 572256 CAFC-X1-S<br>Mounting kit for CPX hood 572257 CAFC-X1-BE<br>Hood section for CPX-P terminal including mounting attachments for connecting 200 mm 572258 CAFC-X1-GAL-200<br>several hood sections in series.<br>300 mm 572259 CAFC-X1-GAL-300<br>User documentation<br>CPX-P system manual German 526445 P.BE-CPX-SYS-DE<br>English 526446 P.BE-CPX-SYS-EN<br>Spanish 526447 P.BE-CPX-SYS-ES<br>French 526448 P.BE-CPX-SYS-FR<br>Italian 526449 P.BE-CPX-SYS-IT<br>**----- End of picture text -----**<br> 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 41 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet ## **User documentation** Comprehensive user documentation is Application-oriented explanations are Device description files and icons are The documents can be downloaded vital for the fast and reliable use of provided for integrating the CPX-P terprovided to support the integration of quickly and easily from the Festo fieldbus components. minal in the programming and configuthe CPX-P terminal in the configuration website. The manuals provided by Festo contain ration software of the various controller software of the various controller mana www.festo.com step-by-step instructions for using the manufacturers. ufacturers. CPX-P terminal: Use the order code to select the 1. Installation language you want. 2. Commissioning and parameteriThe manual for the configuration you sation have ordered is supplied 3. Diagnostics automatically. ## **Overview – User documentation** **==> picture [524 x 332] intentionally omitted <==** **----- Start of picture text -----**<br> Type Title Description<br>Pneumatics<br>P.BE-MPA-... Valve terminals with MPA-S pneumatics Instructions on assembly, installation, commissioning and diagnostics of the MPA-S<br>pneumatic components.<br>Electronics<br>P.BE-CPX-SYS-... System description, installation and commis- Overview of the design, components and mode of operation of the CPX-P terminal; installa-<br>sioning tion and commissioning instructions as well as basic principles of parameterisation.<br>CPX-FVDA-P2-... PROFIsafe shut-off module Connection technology and assembly, installing and commissioning instructions for the<br>PROFIsafe shut-off module of the type CPX-FVDA-P2.<br>P.BE-CPX-EA-... CPX-P-EA modules, digital Connection technology and assembly, installation and commissioning instructions for<br>digital input and output modules of type CPX-... as well as the MPA pneumatic interface.<br>P.BE-CPX-P-EA-... CPX-P-EA modules, NAMUR sensors Connection technology and assembly, installation and commissioning instructions for<br>digital input and output modules of type CPX-P-....<br>CPX-F8DE-P-... Input module CPX-F8DE-N Connection technology and assembly, installation and commissioning instructions for the<br>PROFIsafe input module of type CPX-F8DE-P.<br>P.BE-CPX-2ZE2DA-... I/O-module CPX-2ZE2DA Connection technology and assembly, installation and commissioning instructions for<br>counter modules of type CPX-2ZE2DA.<br>P.BE-CPX-AX-... CPX-P-EA modules, analogue Connection technology and assembly, installation and commissioning instructions for<br>analogue input and output modules of type CPX-...<br>as well as pressure sensors and proportional-pressure regulators.<br>P.BE-CPX-CTEL... CPX CTEL interface Instructions on assembly, installation, commissioning and diagnostics of the CTEL master.<br>P.BE-CPX-CTEL-LK... Electrical interface CPX-CTEL-2 Instructions on assembly, installation, commissioning and diagnostics of the electrical<br>interface for IO-Link.<br>P.BE-CPX-CMIX... CPX measuring module Instructions on assembly, installation, commissioning and diagnostics of the measuring<br>module (CMIX).<br>P.BE-CPX-FB... CPX bus node Instructions on assembly, installation, commissioning and diagnostics of the relevant bus<br>CPX-FB... node.<br>CPX-(M)-FB33_35/43_45... CPX bus node for PROFINET Instructions on assembly, installation, commissioning and diagnostics of the relevant bus<br>node.<br>P.BE-CPX-CEC... CPX-CODESYS controller (control block) Instructions on assembly, installation, commissioning and diagnostics of the relevant<br>control block.<br>**----- End of picture text -----**<br> Subject to change – 2023/10 42 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – CPX-P Maintenance Tool **Function** • Adapters The CPX Maintenance Tool (CPX-FMT) • Software on CD-ROM combines service software with a connecting adapter. The service software is a tool for the design, parameterisation and online diagnostics of the CPX-P terminal. The USB-to-M12 adapter features built-in galvanic isolation (between CPX-P and PC) and enables a PC to be connected to the diagnostic interface of the CPX-P terminal. ## **Application** Only from Festo The CPX-FMT software enables access to CPX valve terminals via Ethernet with the bus nodes EtherNet/IP (FB 36) and PROFINET (FB 33, FB 34, FB 35). The bus nodes or control blocks can be connected directly to a PC via a USB adapter from Festo. Diagnostic data such as the error trace or module diagnostics can be read out and parameters can be modified in plain text. The data can be used directly on a PC. There is an option, for example, to send screenshots of a configuration or the current error trace directly via e-mail. In addition, CPX configurations can also be saved and archived directly as a CPX-FMT project. Undocumented changes can subsequently be identified using the online/offline comparison function. On-site tests such as the actuation of valves or the emulation of sensor feedback (in both cases called "forcing"), for example, can be performed without an existing controller infrastructure. It must be noted that only local parameters on the CPX valve terminal can be changed and saved using the CPX-FMT. The configuration of the networks or controller software cannot be influenced. ## **General technical data** |**General technical data**<br>Type<br>NEFC-M12G5-0.3-U1G5<br>System requirements<br>PC<br>IBM-compatible<br>Drive<br>CD-ROM<br>Interfaces<br>USBport (specification USB 1.1 or higher)<br>Operatingsystem<br>Microsoft Windows 2000 or XP|**General technical data**<br>Type<br>NEFC-M12G5-0.3-U1G5<br>System requirements<br>PC<br>IBM-compatible<br>Drive<br>CD-ROM<br>Interfaces<br>USBport (specification USB 1.1 or higher)<br>Operatingsystem<br>Microsoft Windows 2000 or XP| |---|---| ||CD-ROM| ||USBport (specification USB 1.1 or higher)| ||Microsoft Windows 2000 or XP| |Function range|• Configuration and parameterisation<br>• Reading out of system, module, channel diagnostics and error trace<br>• Saving of the configuration as a project<br>• Integration ofplug-ins/links to self-executing programs| |Scope of delivery|• Adapter, M12, 5-pin to mini USB socket<br>• CD-ROM with installationprogram| |Type of mounting|Screw-in| |Electrical connection|PlugM12x1, 5-pin| |Adapter cable composition|4 x 0.34 mm2| |Cable length<br>[m]|0.3| |Degree ofprotection to EN 60529|IP20| |CE marking(see declaration of conformity)1)|To EU RoHS Directive| |UKCA marking(see declaration of conformity)1)|To UK RoHS instructions| |Ambient temperature<br>[°C]|–5 ... +50| |Material<br>Housing<br>Cable sheath<br>Pin contact|ABS| ||PUR| ||Gold-plated brass| |Note on materials|RoHS-compliant| |PWIS conformity|VDMA24364-B2-L| - 1) Additional information: www.festo.com/catalogue/... d Support/Downloads. 2023/10 – Subject to change 43 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** Data sheet – CPX-P Maintenance Tool **==> picture [523 x 162] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions Download CAD data a www.festo.com<br>[1] Mini B 5P USB port<br>[2] Plug M12x1, 5-pin<br>Ordering data<br>Designation Part no. Type<br>CPX-P Maintenance Tool (CPX-FMT), software and USB-to-M12 adapter 547432 NEFC-M12G5-0.3-U1G5<br>**----- End of picture text -----**<br> Subject to change – 2023/10 d **Internet: www.festo.com/catalogue/...** 44 Terminal CPX-P ## Data sheet – CODESYS controller - Industrial Ethernet The CODESYS controller is a modern • TCP/IP control system for CPX-P terminals that • EasyIP enables programming with CODESYS to • Web interface IEC 61131-3. • Email The power supply to and communica• Data transfer tion with other modules takes place via the interlinking block. In addition to network connections, LEDs are also provided for the bus status, operating status of the PLC and CPX-P peripherals information, as are switching elements and a diagnostic interface for CPX-FMT. **Application** Bus connection Communication protocols Operating modes The CPX-CEC is a remote controller that compact stand-alone controller directly • Fieldbus via CPX-P bus nodes • Stand-alone can be connected to a higher-order PLC on the machine. • Modbus/TCP • Remote controller, fieldbus via the bus nodes of the CPX-P terminal • EasyIP • Remote controller, Ethernet or via Ethernet. At the same time, it is possible to operate the CPX-CEC as a Setting options The CPX-CEC has the following • For the CPX-FMT The operating mode and fieldbus The integrated web server offers a coninterfaces for monitoring, programming • Ethernet interface for IT applications protocol are set using the DIL switch on venient means of querying data saved and commissioning: • Remote diagnostics the CPX-CEC. in the CPX-CEC. Characteristics - Easy control of valve terminal • Activation of decentralised installaconfigurations with MPA, VTSA tion systems on the basis of CPI con- - • Diagnostics with flexible monitoring trol of applications in proportional options for pressure, flow rate, pneumatics cylinder operating time, air • AS-Interface control via gateway consumption - Connection to all fieldbuses as a • Early warnings and visualisation remote controller and for options preprocessing • Servo-pneumatic applications - Control of electric actuators as individual axes via CANopen (CPX-CEC-C1/-M1) 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 45 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – CODESYS controller **==> picture [524 x 608] intentionally omitted <==** **----- Start of picture text -----**<br> General technical data<br>Protocol CODESYS Level 2<br>EasyIP<br>Modbus TCP<br>TCP/IP<br>Processing time Approx. 200 μs/1 k instructions<br>Programming software CODESYS provided by Festo<br>Programming language To IEC 61131-3<br>Sequential function chart (SFC)<br>Instruction list (IL)<br>Function chart (FCH), additional continuous function chart (CFC)<br>Ladder diagram (LD)<br>Structured text (ST)<br>Programming Operating language German, English<br>Support for file handling Yes<br>Device-specific diagnostics Diagnostic memory<br>Channel and module-oriented diagnostics<br>Undervoltage/short-circuit modules<br>LED displays Bus-specific TP: Link/traffic<br>Product-specific RUN: PLC status<br>STOP: PLC status<br>ERR: PLC runtime error<br>PS: Electronics supply, sensor supply<br>PL: Load supply<br>SF: System fault<br>M: Modify/forcing active<br>IP address setting DHCP<br>Via CODESYS<br>Via MMI<br>Function blocks CPX-P diagnostic status, copy CPX-P diagnostic trace, read CPX-P module diagnostics, and<br>more<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 55<br>Materials<br>Housing PA-reinforced<br>PC<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Operating and environmental conditions<br>Ambient temperature [°C] –5 ... +50<br>Storage temperature [°C] –20 ... +70<br>Relative humidity [%] 95, non-condensing<br>Corrosion resistance class CRC [1)] 2<br>1) More information: www.festo.com/x/topic/kbk<br>Electrical data<br>Nominal operating voltage [V DC] 24<br>Load voltage Nominal operating voltage [V DC] 24<br>With pneumatics type VTSA [V DC] 21.6 ... 26.4<br>With pneumatics type MPA [V DC] 18 ... 30<br>Without pneumatics [V DC] 18 ... 30<br>Power failure buffering [ms] 10<br>Intrinsic current consumption at nominal operating voltage [mA] Typically 85<br>Degree of protection to EN 60529 IP65, IP67<br>**----- End of picture text -----**<br> Subject to change – 2023/10 46 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – CODESYS controller ## **Technical data** **==> picture [523 x 291] intentionally omitted <==** **----- Start of picture text -----**<br> Type CPX-CEC-C1-V3 CPX-CEC-M1-V3 CPX-CEC-S1-V3<br>Additional functions Motion functions for electric SoftMotion functions for Diagnostic functions<br>drives electric drives RS232 communica-<br>tion function<br>CPU data Flash [MB] 32<br>RAM [MB] 256<br>Processor [MHz] 800<br>Control interface CAN bus CAN bus –<br>Parameterisation CODESYS V3<br>Configuration support CODESYS V3<br>Program memory, user program [MB] 16<br>Flags CODESYS variable concept<br>Remanent data [kB] 28<br>Control elements DIL switch for CAN termination –<br>Rotary switch for RUN/STOP Rotary switch for RUN/STOP<br>Total number of axes 127 31 –<br>Ethernet Number 1<br>Connection technology RJ45 socket, 8-pin<br>Data transmission speed [Mbps] 1 0/100<br>Supported protocols TCP/IP, EasyIP, Modbus TCP<br>Fieldbus interface Number 1 1<br>Connection technology Sub-D plug, 9-pin Sub-D socket, 9-pin<br>Data transmission speed, can be set [kbps] 125, 250, 500, 800, 1000 9.6 ... 230.4<br>via software<br>Supported protocols CAN bus RS232 interface<br>Max. cable length [m] – 30<br>Galvanic isolation Yes Yes<br>**----- End of picture text -----**<br> 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 47 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – CODESYS controller ## **Connection and display elements CPX-CEC-C1/-M1** **==> picture [161 x 137] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>4<br>2 5<br>3<br>6<br>**----- End of picture text -----**<br> - [1] CPX-FMT connection - [2] DIL switch - [3] Fieldbus interface (Sub-D plug, 9-pin) - [4] Status LEDs, bus-specific and product-specific - [5] RUN/STOP rotary switch - [6] Ethernet interface (RJ45 socket, 8-pin) ## **Pin allocation – CPX-CEC-C1/-M1** **==> picture [524 x 246] intentionally omitted <==** **----- Start of picture text -----**<br> Pin Signal Meaning<br>Fieldbus interface, Sub-D plug<br>1 n.c. Not connected<br>2 CAN_L CAN low<br>3 CAN_GND CAN ground<br>4 n.c. Not connected<br>5 CAN_SHLD Connection to functional earth FE<br>6 CAN_GND CAN ground (optional) [1)]<br>7 CAN_H CAN high<br>8 n.c. Not connected<br>9 n.c. Not connected<br>Housing Shielding Plug housing must be connected to FE<br>Ethernet interface, RJ45 plug<br>1 TD+ Transmitted data+<br>2 TD- Transmitted data-<br>3 RD+ Received data+<br>4 n.c. Not connected<br>5 n.c. Not connected<br>6 RD- Received data-<br>7 n.c. Not connected<br>8 n.c. Not connected<br>Housing Shielding Shielding<br>**----- End of picture text -----**<br> 1) If a servo drive is connected to an external power supply, CAN ground (optional), pin 6, cannot be used on the CPX-CEC-C1/-M1. Subject to change – 2023/10 48 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – CODESYS controller ## **Connection and display elements CPX-CEC-S1** **==> picture [523 x 401] intentionally omitted <==** **----- Start of picture text -----**<br> [1] CPX-FMT connection<br>1 [2] DIL switch<br>4<br>[3] RS232 interface<br>(Sub-D socket, 9-pin)<br>2 [4] Status LEDs, bus-specific and<br>5<br>product-specific<br>3 [5] RUN/STOP rotary switch<br>6 [6] Ethernet interface (RJ45 socket,<br>8-pin)<br>Pin allocation – CPX-CEC-S1<br>Terminal allocation Pin Signal Designation<br>RS 232 interface, Sub-D socket<br>1 n.c. Not connected<br>2 RxD Received data<br>3 TxD Transmitted data<br>4 n.c. Not connected<br>5 GND Data reference potential<br>6 n.c. Not connected<br>7 n.c. Not connected<br>8 n.c. Not connected<br>9 n.c. Not connected<br>Shielding Shielding Connection to functional earth<br>Ethernet interface, RJ45 plug<br>1 TD+ Transmitted data+<br>2 TD- Transmitted data-<br>3 RD+ Received data+<br>4 n.c. Not connected<br>5 n.c. Not connected<br>6 RD- Received data-<br>7 n.c. Not connected<br>8 n.c. Not connected<br>Housing Shielding Shielding<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 49 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – CODESYS controller ## **Ordering data** **==> picture [524 x 433] intentionally omitted <==** **----- Start of picture text -----**<br> Designation Part no. Type<br>Control block<br>Motion functions for electric drives 135 g 3473128 CPX-CEC-C1-V3<br>SoftMotion functions for electric drives 135 g 3472765 CPX-CEC-M1-V3<br>RS232 communication function 135 g 3472425 CPX-CEC-S1-V3<br>Fieldbus interface<br>Sub-D plug, 9-pin, for CANopen 532219 FBS-SUB-9-BU-2x5POL-B<br>Micro style bus connection, 2xM12 for DeviceNet/CANopen 525632 FBA-2-M12-5POL<br>Socket for micro style connection, M12 18324 FBSD-GD-9-5POL<br>Plug for micro style connection, M12 175380 FBS-M12-5GS-PG9<br>Open style bus connection for 5-pin terminal strip for DeviceNet/CANopen 525634 FBA-1-SL-5POL<br>Terminal strip for open style connection, 5-pin 525635 FBSD-KL-2x5POL<br>Ethernet interface<br>RJ45 plug Degree of protection IP 65, IP67 534494 FBS-RJ45-8-GS<br>Cover for RJ45 connection Degree of protection IP 65, IP67 534496 AK-RJ45<br>Straight plug, RJ45, 8-pin Straight plug, M12x1, 4-pin, Degree of protec- 1 m 8040451 NEBC-D12G4-ES-1-S-R3G4-ET<br>D-coded tion IP20 3 m 8040452 NEBC-D12G4-ES-3-S-R3G4-ET<br>5 m 8040453 NEBC-D12G4-ES-5-S-R3G4-ET<br>10 m 8040454 NEBC-D12G4-ES-10-S-R3G4-ET<br>Straight plug, RJ45, 8-pin Straight plug, RJ45, 8-pin Degree of protec- 1 m 8040455 NEBC-R3G4-ES-1-S-R3G4-ET<br>tion IP20<br>**----- End of picture text -----**<br> Subject to change – 2023/10 50 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Control block CPX-CEC **==> picture [523 x 179] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Covers and attachments<br>Inspection cover, transparent, for Sub-D connection 533334 AK-SUB-9/15-B<br>Inscription label holder for connection block 536593 CPX-ST-1<br>User documentation<br>Manual for control block CPX-CEC German 569121 P.BE-CPX-CEC-DE<br>English 569122 P.BE-CPX-CEC-EN<br>**----- End of picture text -----**<br> 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 51 Terminal CPX-P ## Data sheet – DeviceNet bus node Bus node for handling communication between the electrical terminal CPX-P and a DeviceNet network. The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules. The status of the CPX-P terminal is displayed as a common message via 4 CPX-P-specific LEDs. The fieldbus communication status is displayed via the three DeviceNet-specific LEDs. ## **Application** ## Bus connection The bus connection can be selected when ordering, either micro style as 2xM12 round plugs or open style as a terminal strip with IP20 protection. Both connection types have the function of an integrated T-distributor with incoming and outgoing bus line. ## DeviceNet implementation The CPX-FB11 operates with the Predefined Master/Slave Connection Set as a Group 2 Only Server. The polled I/O, change of state or cyclic method is used for the transmission of cyclic I/O data. The type of transmission can be selected in the network configuration. The device diagnostics for all bus nodes CPX-FB11 is effectively gathered via strobed I/O and displayed in the input table of the controller. In addition to cyclic data transmission, acyclic communication is supported through explicit messaging, which enables detailed device diagnostics and parameterisation. A comprehensive EDS file supports the display of acyclic data. It is also possible to display system information and assign parameters while the controller is running via the user program or the configuration software. An example of this is access to the integrated diagnostic memory function, i.e. storage of the last 40 errors with timestamp, module, channel and error type. With its address capacity of 64 byte inputs and 64 byte outputs, the CPX-FB11 supports any configuration of I/O modules, including pneumatic interface. ## Points to note in connection with CPX-CEC When a bus node is combined with a control block (CPX-CEC, in the fieldbus remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX-P control block. In this case, the bus node only provides the communication interface to the PLC. Communication between the control block and CPX-P bus node takes place by interlinking the CPX-P modules and takes up the following address capacity in the CPX-P system: - 8 byte outputs • 8 byte inputs The following address capacity remains in the control block or CPX system for activating the peripherals: - 56 byte inputs • 56 byte outputs 52 d **Internet: www.festo.com/catalogue/...** Subject to change – 2023/10 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – DeviceNet bus node ## **General technical data** **==> picture [523 x 376] intentionally omitted <==** **----- Start of picture text -----**<br> Type CPX-FB11<br>Fieldbus interface Either<br>• Micro style bus connection: 2xM12 with degree of protection IP65/IP67<br>• Open style bus connection: 5-pin terminal strip, IP20<br>Baud rate [kbps] 125, 250, 500<br>Addressing range 0 ... 63<br>Set using DIL switch<br>Product Type Communication adapter (12 dec.)<br>Code 4554 dec.<br>Types of communication Polled I/O, change of state/cyclic, strobed I/O and explicit messaging<br>Configuration support EDS file and bitmaps<br>Max. address capacity Inputs [byte] 64<br>Outputs [byte] 64<br>LED displays (bus-specific) MS = Module status<br>NS = Network status<br>IO = I/O status<br>Device-specific diagnostics Module and channel-oriented diagnostics via manufacturer-specific diagnostic object<br>Parameterisation • Module and system parameterisation via configuration interface in plain text (EDS)<br>• Online in run or program mode<br>Additional functions • Storage of the last 40 errors with timestamp (access via EDS)<br>• 8-bit system status in process image for inputs<br>• 2-byte inputs and 2-byte outputs, system diagnostics in process image<br>Control elements DIL switch<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Power failure buffering [ms] 10<br>Current consumption [mA] Typically 200<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Materials PA-reinforced, PC<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 120<br>**----- End of picture text -----**<br> ## - **Note** H- Please observe the general limits and guidelines for the system when configuring the electrical modules. 2023/10 – Subject to change 53 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – DeviceNet bus node ## **Connection and display components** **==> picture [161 x 137] intentionally omitted <==** **----- Start of picture text -----**<br> MS PS<br>NS PL<br>1 IO SF 2<br>M<br>4 3<br>**----- End of picture text -----**<br> - [1] Bus-specific LEDs [2] CPX-P-specific status LEDs [3] Selectable fieldbus interface Micro style Open style - [4] DIL switch cover **==> picture [524 x 404] intentionally omitted <==** **----- Start of picture text -----**<br> Pin allocation for the DeviceNet interface<br>Terminal allocation Pin Signal-specific Signal Designation<br>wire colour [1)]<br>Sub-D plug<br>1 – n.c. Not connected<br>2 Blue CAN_L Received/transmitted data low<br>3 Black 0 V bus 0 V CAN interface<br>4 – n.c. Not connected<br>5 Bare Shielding Connection to housing<br>6 – n.c. Not connected<br>7 White CAN_H Received/transmitted data high<br>8 – n.c. Not connected<br>9 Red 24 V DC bus 24 V DC supply CAN interface<br>Micro style bus connection (M12), incoming/outgoing<br>Incoming 1 Bare Shielding Connection to housing<br>2 Red 24 V DC bus 24 V DC supply CAN interface<br>3 Black 0 V bus 0 V CAN interface<br>4 White CAN_H Received/transmitted data high<br>5 Blue CAN_L Received/transmitted data low<br>Outgoing 1 Bare Shielding Connection to housing<br>2 Red 24 V DC bus 24 V DC supply CAN interface<br>3 Black 0 V bus 0 V CAN interface<br>4 White CAN_H Received/transmitted data high<br>5 Blue CAN_L Received/transmitted data low<br>Open style bus connection<br>1 Black 0 V bus 0 V CAN interface<br>2 Blue CAN_L Received/transmitted data low<br>3 Bare Shielding Connection to housing<br>1 2 3 4 5 4 White CAN_H Received/transmitted data high<br>5 Red 24 V DC bus 24 V DC supply CAN interface<br>7/8" bus connection<br>1 Black Shielding Connection to housing<br>2 Blue 24 V DC 24 V DC supply CAN interface<br>3 Bare 0 V 0 V CAN interface<br>4 White CAN_H Received/transmitted data high<br>5 Red CAN_L Received/transmitted data low<br>**----- End of picture text -----**<br> 1) Typical for DeviceNet cables Subject to change – 2023/10 d **Internet: www.festo.com/catalogue/...** 54 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – DeviceNet bus node **==> picture [523 x 509] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Bus node<br>DeviceNet bus node 526172 CPX-FB11<br>Bus connection<br>Sub-D plug 532219 FBS-SUB-9-BU-2x5POL-B<br>Connection block, 9-pin Sub-D socket, 5-pin 7/8" plug 571052 CPX-AB-1-7/8-DN<br>Micro style bus connection, 2xM12 525632 FBA-2-M12-5POL<br>Socket for micro style connection, M12 18324 FBSD-GD-9-5POL<br>Plug for micro style connection, M12 175380 FBS-M12-5GS-PG9<br>Open style bus connection for 5-pin terminal strip 525634 FBA-1-SL-5POL<br>Terminal strip for open style connection, 5-pin 525635 FBSD-KL-2x5POL<br>Covers<br>Cover cap for sealing unused M12 connections (10 pieces) 165592 ISK-M12<br>Inspection cover, transparent, for Sub-D connection 533334 AK-SUB-9/15-B<br>Inscription label<br>Inscription label holder for connection block 536593 CPX-ST-1<br>Inscription labels 6x10 mm, 64 pieces, in frame 18576 IBS-6x10<br>**----- End of picture text -----**<br> 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 55 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – DeviceNet bus node ## **Ordering data** **==> picture [524 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> Designation Part no. Type<br>User documentation<br>User documentation for bus node CPX-FB11 German 526421 P.BE-CPX-FB11-DE<br>English 526422 P.BE-CPX-FB11-EN<br>Spanish 526423 P.BE-CPX-FB11-ES<br>French 526424 P.BE-CPX-FB11-FR<br>Italian 526425 P.BE-CPX-FB11-IT<br>Software<br>Adapter M12, 5-pin to mini USB socket, and controller software 547432 NEFC-M12G5-0.3-U1G5<br>**----- End of picture text -----**<br> Subject to change – 2023/10 56 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – PROFIBUS bus node Bus node for handling communication between the electrical terminal CPX-P and a higher-order master via PROFIBUS DP. The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules. The status of the CPX-P terminal is displayed as a common message via 4 CPX-P-specific LEDs. The fieldbus communication status is displayed via the PROFIBUS-specific error LED. **Application** Bus connection The bus connection is established via The bus connector plug (with degree of An active bus terminal can be connectThe Sub-D interface is designed for a 9-pin Sub-D socket with a typical protection IP65/IP67 from Festo or ed using the DIL switch integrated in controlling network components with a PROFIBUS allocation (to EN 50170). degree of protection IP20 from other the plug. fibre-optic cable connection. manufacturers) facilitates the connection of an incoming and an outgoing bus cable. PROFIBUS DP implementation The CPX-FB13 supports the PROFIBUS In addition to DPV0, acyclic communiAn example of this is access to the inWith its address capacity of 64 byte DP protocol to EN 50170 Volume 2 for cation to the advanced specification tegrated diagnostic memory function, inputs and 64 byte outputs, the cyclic I/O exchange, parameterisation DPV1 is supported. DPV1 provides acyi.e. storage of the last 40 errors with CPX-FB13 supports any configuration and diagnostic functions (DPV0). clic access to advanced system infortimestamp, module, channel and error of I/O modules, including pneumatic mation and allows parameterisation type. interface. while the controller is running via the user program. Points to note in connection with CPX-CEC When a bus node is combined with a In this case, the bus node only pro• 8 byte outputs The following address capacity remains control block (CPX-CEC, in the fieldbus vides the communication interface to • 8 byte inputs in the control block or CPX system for remote controller operating mode), the the PLC. activating the peripherals: connected I/Os and/or valves, sensors Communication between the control • 56 byte inputs and actuators are controlled via the block and CPX-P bus node takes place • 56 byte outputs CPX-P control block. by interlinking the CPX-P modules and takes up the following address capacity in the CPX-P system: 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 57 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – PROFIBUS bus node ## **General technical data** **==> picture [524 x 352] intentionally omitted <==** **----- Start of picture text -----**<br> Type CPX-FB13<br>Fieldbus interface Sub-D socket, 9-pin (EN 50170)<br>Galvanically isolated 5 V<br>Baud rate [Mbps] 0.0096 ... 12<br>Addressing range 1 ... 125<br>Set using DIL switch<br>Product family 4: Valves<br>ID number 0x059E<br>Types of communication DPV0: Cyclic communication<br>DPV1: Acyclic communication<br>Configuration support GSD file and bitmaps<br>Max. address capacity Inputs [byte] 64<br>Outputs [byte] 64<br>LED displays (bus-specific) BF: Bus fault<br>Device-specific diagnostics Identifier and channel-oriented diagnostics to EN 50170 (PROFIBUS standard)<br>Parameterisation • Start-up parameterisation via configuration interface in plain text (GSD)<br>• Acyclic parameterisation via DPV1<br>Additional functions • Storage of the last 40 errors with timestamp (access via DPV1)<br>• 8-bit system status in process image for inputs<br>• 2-byte inputs and 2-byte outputs, system diagnostics in process image<br>Control elements DIL switch<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Power failure buffering [ms] 10<br>Current consumption [mA] Typically 200<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Materials PA-reinforced, PC<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 115<br>**----- End of picture text -----**<br> ## - **Note** H- Please observe the general limits and guidelines for the system when configuring the electrical modules. Subject to change – 2023/10 58 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – PROFIBUS bus node ## **Connection and display components** |1|||**��**<br>**�**<br>**�**<br>**�**<br>**���**<br>**�**|**��**<br>**�**<br>**�**<br>**�**<br>**���**<br>**�**||2<br>3<br>[1] Bus status LEDs/bus fault<br>[2] CPX-P-specifc status LEDs<br>[3] Fieldbus interface (Sub-D socket,<br>9-pin)<br>[4] DIL switch cover| |---|---|---|---|---|---|---| |4||||||| |||||||| |||||||| |||||||| |||||||| ## **Pin allocation for PROFIBUS DP interface** **==> picture [523 x 262] intentionally omitted <==** **----- Start of picture text -----**<br> Terminal allocation Pin Signal Designation<br>Sub-D socket<br>1 n.c. Not connected<br>2 n.c. Not connected<br>3 RxD/TxD-P Received/transmitted data P<br>4 CNTR-P [1)] Repeater control signal<br>5 DGND Data reference potential (M5V)<br>6 VP Supply voltage (P5V)<br>7 n.c. Not connected<br>8 RxD/TxD-N Received/transmitted data N<br>9 n.c. Not connected<br>Housing Shielding Connection to housing<br>Bus connection M12 adapter (B-coded)<br>Incoming 1 n.c. Not connected<br>2 RxD/TxD-N Received/transmitted data N<br>3 n.c. Not connected<br>4 RxD/TxD-P Received/transmitted data P<br>5 and M12 Shielding Connection to FE (functional earth)<br>Outgoing 1 VP Supply voltage (P5V)<br>2 RxD/TxD-N Received/transmitted data N<br>3 DGND Data reference potential (M5V)<br>4 RxD/TxD-P Received/transmitted data P<br>5 and M12 Shielding Connection to FE (functional earth)<br>**----- End of picture text -----**<br> 1) The repeater control signal CNTR-P is realised as a TTL signal. 2023/10 – Subject to change 59 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – PROFIBUS bus node **==> picture [524 x 558] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Bus node<br>PROFIBUS bus node 195740 CPX-FB13<br>Bus connection<br>Sub-D plug, straight 532216 FBS-SUB-9-GS-DP-B<br>Sub-D plug, angled 533780 FBS-SUB-9-WS-PB-K<br>Bus connection, adapter from 9-pin Sub-D plug to 5-pin M12 plug/socket, B-coded 533118 FBA-2-M12-5POL-RK<br>Connection block, adapter from 9-pin Sub-D plug to 5-pin M12 plug/socket, B-coded 541519 CPX-AB-2-M12-RK-DP<br>5-pin M12x1 straight socket, 1067905 NECU-M-B12G5-C2-PB<br>for self-assembly of a connecting cable compatible with FBA-2-M12-5POL-RK and CPX-AB-2-M12-RK-DP<br>Plug M12x1, 5-pin, straight, 1066354 NECU-M-S-B12G5-C2-PB<br>for self-assembly of a connecting cable compatible with FBA-2-M12-5POL-RK and CPX-AB-2-M12-RK-DP<br>Terminating resistor, M12, B-coded for PROFIBUS 1072128 CACR-S-B12G5-220-PB<br>Covers<br>Cover cap for sealing unused M12 connections (10 pieces) 165592 ISK-M12<br>Inspection cover, transparent, for Sub-D connection 533334 AK-SUB-9/15-B<br>Inscription label<br>Inscription label holder for connection block 536593 CPX-ST-1<br>Inscription labels 6x10 mm, 64 pieces, in frame 18576 IBS-6x10<br>**----- End of picture text -----**<br> Subject to change – 2023/10 60 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – CPX-FB13 bus node, PROFIBUS DP ## **Ordering data** **==> picture [523 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> Designation Part no. Type<br>User documentation<br>User documentation for bus node CPX-FB13 German 526427 P.BE-CPX-FB13-DE<br>English 526428 P.BE-CPX-FB13-EN<br>Spanish 526429 P.BE-CPX-FB13-ES<br>French 526430 P.BE-CPX-FB13-FR<br>Italian 526431 P.BE-CPX-FB13-IT<br>Software<br>Adapter M12, 5-pin to mini USB socket, and controller software 547432 NEFC-M12G5-0.3-U1G5<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 61 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – CANopen bus node Bus node for handling communication between the electrical terminal CPX-P CANopen atti. and a CANopen network master or CANopen network. The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules. The status of the CPX-P terminal is displayed as a common message via 4 CPX-P-specific LEDs. The different CANopen statuses and the fieldbus communication status are visualised via 3 additional LEDs. **Application** Bus connection The bus connection is established via The bus connector plug (with degree of There are 4 contacts available for the a 9-pin Sub-D plug (pin) as per the CAN protection IP65/IP67 from Festo or de4 wires (CAN_L, CAN_H, 24 V, 0 V) of in Automation (CiA) specification gree of protection IP20 from other the incoming and outgoing bus cables DS 102 with additional 24 V CAN manufacturers) facilitates the connecrespectively. transceiver supply (option as per tion of an incoming and an outgoing DS 102). bus cable. CANopen implementation The CPX-FB14 supports the CANopen Enhanced system information can also With its address capacity, the CPX8 analogue input channels and 8 anaprotocol in accordance with the be accessed via SDO communication. FB14 supports a large number of I/O logue output channels can be adspecifications DS 301 V4.01 and SDO communication also facilitates module configurations, including dressed via PDO 2 and 3. Status and DS 401 V2.0. parameterisation before network startpneumatic interface. diagnostic information can be evaluatImplementation is based on the CiA up or while the controller is running via By default, 8 byte digital inputs and 8 ed via PDO 4. Predefined Connection Set. the user program. byte digital outputs can be addressed Additional 8 byte digital inputs and There are 4 PDOs available for fast I/O An example of this is access to the invia PDO 1. outputs as well as 8 analogue input data exchange. tegrated diagnostic memory function, and output channels can be addressed i.e. storage of the last 40 errors with via mapping. timestamp, module, channel and error type. Points to note in connection with CPX-CEC When a bus node is combined with a In this case, the bus node only pro• 8 byte outputs The following address capacity remains control block (CPX-CEC, in the fieldbus vides the communication interface to • 8 byte inputs in the control block or CPX system for remote controller operating mode), the the PLC. activating the peripherals: connected I/Os and/or valves, sensors Communication between the control • 56 byte inputs and actuators are controlled via the block and CPX-P bus node takes place • 56 byte outputs CPX-P control block. by interlinking the CPX-P modules and takes up the following address capacity in the CPX-P system: Subject to change – 2023/10 62 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – CANopen bus node ## **General technical data** **==> picture [523 x 437] intentionally omitted <==** **----- Start of picture text -----**<br> Type CPX-FB14<br>Fieldbus interface Sub-D plug, 9-pin (to DS 102)<br>Bus interface galvanically isolated via optocoupler 24 V supply for CAN interface via bus<br>Baud rate [kbps] 125, 250, 500 and 1000 can be set via DIL switch<br>Addressing range Node ID 1 ... 127<br>Set using DIL switch<br>Product family Digital inputs and outputs<br>Communication profile DS 301, V4.01<br>Device profile DS 401, V2.0<br>Number PDO 4 Tx/4 Rx<br>SDO 1 server SDO<br>Configuration support EDS file and bitmaps<br>Max. address capacity Inputs [byte] 16 digital, 16 analogue channels<br>Outputs [byte] 16 digital, 16 analogue channels<br>LED displays (bus-specific) MS = Module status<br>NS = Network status<br>IO = I/O status<br>Device-specific diagnostics Via emergency message<br>Object 1001, 1002 and 1003<br>Parameterisation Via SDO<br>Additional functions • Storage of the last 40 errors with timestamp (access via SDO)<br>• 8-bit system status via transmit PDO 4 (default)<br>• 2-byte inputs and 2-byte outputs, system diagnostics via PDO 4<br>• Minimum boot-up<br>• Variable PDO mapping<br>• Emergency message<br>• Node guarding<br>• Heart beat<br>Control elements DIL switch<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Power failure buffering [ms] 10<br>Current consumption [mA] Typically 200<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Materials PA-reinforced, PC<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 115<br>**----- End of picture text -----**<br> ## - **Note** H- Please observe the general limits and guidelines for the system when configuring the electrical modules. 2023/10 – Subject to change 63 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – CANopen bus node ## **Connection and display components** ||||||2| |---|---|---|---|---|---| ||||||3| ||||||| ||||||| ||||||| ||||||| [1] Bus-specific LEDs [2] CPX-P-specific status LEDs [3] Fieldbus interface (Sub-D plug, 9-pin) [4] DIL switch cover **==> picture [524 x 341] intentionally omitted <==** **----- Start of picture text -----**<br> Pin allocation of the CANopen interface<br>Terminal allocation Pin Signal Designation<br>Sub-D plug<br>1 n.c. Not connected<br>2 CAN_L Received/transmitted data low<br>3 CAN_GND 0 V CAN interface<br>4 n.c. Not connected<br>5 CAN_SHLD Optional shielded connection<br>6 GND Ground [1)]<br>7 CAN_H Received/transmitted data high<br>8 n.c. Not connected<br>9 CAN_V+ 24 V DC supply CAN interface<br>Housing Shielding Connection to FE (functional earth)<br>Micro style bus connection (M12)<br>Incoming 1 Shielding Connection to FE (functional earth)<br>2 CAN_V+ 24 V DC supply CAN interface<br>3 CAN_GND 0 V CAN interface<br>4 CAN_H Received/transmitted data high<br>5 CAN_L Received/transmitted data low<br>Outgoing 1 Shielding Connection to FE (functional earth)<br>2 CAN_V+ 24 V DC supply CAN interface<br>3 CAN_GND 0 V CAN interface<br>4 CAN_H Received/transmitted data high<br>5 CAN_L Received/transmitted data low<br>Open style bus connection<br>1 CAN_GND 0 V CAN interface<br>2 CAN_L Received/transmitted data low<br>3 Shielding Connection to FE (functional earth)<br>1 2 3 4 5 4 CAN_H Received/transmitted data high<br>5 CAN_V+ 24 V DC supply CAN interface<br>**----- End of picture text -----**<br> 1) Connected internally via Pin 3 Subject to change – 2023/10 64 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – CANopen bus node **==> picture [523 x 631] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Bus node<br>CANopen bus node 526174 CPX-FB14<br>Bus connection<br>Sub-D socket for CANopen with terminating resistor and programming interface 574588 NECU-S1W9-C2-ACO<br>Sub-D socket 532219 FBS-SUB-9-BU-2x5POL-B<br>Sub-D socket, angled 533783 FBS-SUB-9-WS-CO-K<br>Connection block, 9-pin Sub-D socket, 5-pin 7/8" plug 571052 CPX-AB-1-7/8-DN<br>Micro style bus connection, 2xM12, 5-pin 525632 FBA-2-M12-5POL<br>Fieldbus socket for micro style connection, M12, 5-pin 18324 FBSD-GD-9-5POL<br>Plug for micro style connection, M12, 5-pin 175380 FBS-M12-5GS-PG9<br>Open style bus connection 525634 FBA-1-SL-5POL<br>Terminal strip for open style connection, 5-pin 525635 FBSD-KL-2x5POL<br>Inspection cover, transparent 533334 AK-SUB-9/15-B<br>Inscription label holder for connection block 536593 CPX-ST-1<br>User documentation<br>User documentation for bus node CPX-FB14 German 526409 P.BE-CPX-FB14-DE<br>English 526410 P.BE-CPX-FB14-EN<br>Spanish 526411 P.BE-CPX-FB14-ES<br>French 526412 P.BE-CPX-FB14-FR<br>Italian 526413 P.BE-CPX-FB14-IT<br>Software<br>Adapter M12, 5-pin to mini USB socket, and controller software 547432 NEFC-M12G5-0.3-U1G5<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 65 d **Internet: www.festo.com/catalogue/...** ## Terminal CPX-P Data sheet – PROFINET bus node, M12, D-coded Bus node for operating the CPX-P valve terminal on PROFINET. The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules. The status of the CPX-P terminal is displayed as a common message via 4 CPX-P-specific LEDs. The fieldbus communication status is displayed via three bus-specific LEDs. ## **Application** Bus connection The bus connection is established via two M12 sockets, D-coded to IEC 61076-2-101 with degree of protection IP65, IP67. Both connections are equivalent 100BaseTX Ethernet ports with integrated auto MDI functionality (crossover and patch cables can be used) that are brought together via an internal switch. • Maximum segment length 100 m • Transmission rate 100 Mbps ## PROFINET implementation The bus node supports the PROFINET protocol on the basis of the Ethernet standard and TCP/IP technology to IEEE802.3. This guarantees a data exchange with a high data transmission rate, for example I/O data from sensors, actuators or robot controllers, PLCs or process equipment. In addition, non-real-time critical information such as diagnostic information, configuration information, etc. can be transferred. The Ethernet bandwidth is sufficient to transfer both data types (real-time and non-realtime) in parallel. The bus node features LEDs for bus status and CPX-P peripheral information as well as switch elements and a diagnostic interface. PROFINET provides the user with access to all peripherals, diagnostic data and parameter data of the CPX-P valve terminal. The bus node can be used as a remote I/O or remote controller. All information relevant to the CPX-P can be read out and, depending on the function, changed via the diagnostic interface. ## Points to note in connection with CPX-CEC When a bus node is combined with a control block (CPX-CEC, in the fieldbus remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX-P control block. In this case, the bus node only provides the communication interface to the PLC. Communication between the control block and CPX-P bus node takes place by interlinking the CPX-P modules and takes up the following address capacity in the CPX-P system: • 8 byte outputs • 8 byte inputs The following address capacity remains in the control block or CPX system for activating the peripherals: • 56 byte inputs • 56 byte outputs 66 d **Internet: www.festo.com/catalogue/...** Subject to change – 2023/10 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – PROFINET bus node, M12, D-coded **==> picture [523 x 495] intentionally omitted <==** **----- Start of picture text -----**<br> General technical data<br>Type CPX-FB43<br>Fieldbus interface 2x socket, M12, 4-pin, D-coded<br>Baud rate [Mbps] 100<br>Protocol PROFINET RT<br>PROFINET IRT<br>Max. address capacity Inputs [byte] 64<br>Outputs [byte] 64<br>LED displays (bus-specific) M/P = Maintenance/PROFIenergy<br>NF = Network fault<br>TP1 = Network active port 1<br>TP2 = Network active port 2<br>(product-specific) M = Modify, parameterisation<br>PL = Load supply<br>PS = Electronic supply, sensor supply<br>SF = System fault<br>Device-specific diagnostics • Channel and module-oriented diagnostics<br>• Undervoltage of modules<br>• Diagnostic memory<br>Configuration support GSDML file<br>Parameterisation • System parameters<br>• Diagnostic behaviour<br>• Signal setup<br>• Fail-safe response<br>• Forcing of channels<br>Additional functions • Start-up parameterisation in plain text via fieldbus<br>• Fast start-up (FSU)<br>• Channel-oriented diagnostics via fieldbus<br>• Acyclic data access via fieldbus<br>• System status can be displayed using process data<br>• Additional diagnostic interface for operator units<br>• Acyclic data access via Ethernet<br>• I&M, LLDP, MRP, MRPD, MQTT, PROFIsafe, PROFIenergy, S2 system redundancy<br>Control elements • DIL switch<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Current consumption [mA] Typically 70<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] – 5... +50<br>Storage/transport [°C] –20 ... +70<br>Certification RCM<br>Materials Housing Die-cast aluminium<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 185<br>**----- End of picture text -----**<br> ## - **Note** H- Please observe the general limits and guidelines for the system when configuring the electrical modules. ## - **Note** H- Always use the correct screws for the • Self-tapping screws for plastic • Screws with metric thread for interlinking block; this depends on interlinking blocks metal interlinking blocks whether the block is made of metal or plastic: 2023/10 – Subject to change 67 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – PROFINET bus node, M12, D-coded ## **Connection and display components** |1|||||2<br>3<br>[1] Bus-specifc status LEDs<br>[2] CPX-P-specifc status LEDs<br>[3] Fieldbus interface (M12 socket,<br>4-pin, D-coded)<br>[4] Transparent cover for DIL switch| |---|---|---|---|---|---| |4|||||| ||||||| |3|||||| ||||||| ## **Pin allocation for the fieldbus interface** **==> picture [524 x 110] intentionally omitted <==** **----- Start of picture text -----**<br> Terminal allocation Pin Signal Designation<br>Socket, M12, D-coded<br>1 TD+ Transmitted data+<br>2 RD+ Received data+<br>3 TD- Transmitted data-<br>4 RD- Received data-<br>Housing Shielding<br>**----- End of picture text -----**<br> Subject to change – 2023/10 68 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – PROFINET bus node, M12, D-coded **==> picture [523 x 438] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Bus node<br>PROFINET bus node • I&M 8110369 CPX-FB43<br>• LLDP<br>• MRP<br>• MRPD<br>• PROFIenergy<br>• S2 system redundancy<br>Bus connection<br>Plug M12x1, 4-pin, D-coded 543109 NECU-M-S-D12G4-C2-ET<br>Connecting cable, Straight plug, M12x1, 0.5 m 8040446 NEBC-D12G4-ES-0.5-S-D12G4-ET<br>straight plug, M12x1, 4-pin, D-coded 1 m 8040447 NEBC-D12G4-ES-1-S-D12G4-ET<br>4-pin, D-coded 3 m 8040448 NEBC-D12G4-ES-3-S-D12G4-ET<br>5 m 8040449 NEBC-D12G4-ES-5-S-D12G4-ET<br>10 m 8040450 NEBC-D12G4-ES-10-S-D12G4-ET<br>Straight plug, RJ45, 1 m 8040451 NEBC-D12G4-ES-1-S-R3G4-ET<br>8-pin 3 m 8040452 NEBC-D12G4-ES-3-S-R3G4-ET<br>5 m 8040453 NEBC-D12G4-ES-5-S-R3G4-ET<br>10 m 8040454 NEBC-D12G4-ES-10-S-R3G4-ET<br>Open end, 4-wire 5 m 8040456 NEBC-LE4-ES-5-D12G4-ET<br>Transparent cover for DIL switch 548757 CPX-AK-P<br>Cover cap for sealing unused bus connections (10 pieces) 165592 ISK-M12<br>User documentation<br>Electronics manual, CPX bus node German 548759 CPX-(M)-FB33_35/43_45-DE<br>English 548760 CPX-(M)-FB33_35/43_45-EN<br>Spanish 548761 CPX-(M)-FB33_35/43_45-ES<br>French 548762 CPX-(M)-FB33_35/43_45-FR<br>Italian 548763 CPX-(M)-FB33_35/43_45-IT<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 69 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – PROFINET bus node, push-pull RJ45 Bus node for operating the CPX-P terminal on PROFINET. The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules. The status of the CPX-P terminal is displayed as a common message via 4 CPX-P-specific LEDs. The fieldbus communication status is displayed via three bus-specific LEDs. ## **Application** Bus connection The bus connection is established via two RJ45 push-pull sockets to IEC 61076-3-106 and IEC 60603 with degree of protection IP65, IP67. Both connections are equivalent 100BaseTX Ethernet ports with integrated auto MDI functionality (crossover and patch cables can be used) that are brought together via an internal switch. - Maximum segment length 100 m - Transmission rate 100 Mbps ## PROFINET implementation The bus node supports the PROFINET protocol on the basis of the Ethernet standard and TCP/IP technology to IEEE802.3. This guarantees a data exchange with a high data transmission rate, for example I/O data from sensors, actuators or robot controllers, PLCs or process equipment. In addition, non-real-time critical information such as diagnostic information, configuration information, etc. can be transferred. The Ethernet bandwidth is sufficient to transfer both data types (real-time and non-real-time) in parallel. The bus node features LEDs for bus status and CPX-P peripheral information as well as switch elements and a diagnostic interface. PROFINET provides the user with access to all peripherals, diagnostic and parameter data of the CPX-P terminal. The bus node can be used as a remote I/O or remote controller. All information relevant to the CPX-P can be read out and, depending on the function, changed via the diagnostic interface. ## Points to note in connection with CPX-CEC When a bus node is combined with a control block (CPX-CEC, in the fieldbus remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX-P control block. In this case, the bus node only provides the communication interface to the PLC. Communication between the control block and CPX-P bus node takes place by interlinking the CPX-P modules and takes up the following address capacity in the CPX-P system: - 8/16 byte outputs • 8/16 byte inputs The following address capacity remains in the control block or CPX system for activating the peripherals: - 56/48 byte inputs - 56/48 byte outputs Subject to change – 2023/10 70 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – PROFINET bus node, push-pull RJ45 **==> picture [523 x 485] intentionally omitted <==** **----- Start of picture text -----**<br> General technical data<br>Type CPX-M-FB44<br>Fieldbus interface 2x RJ45 push-pull socket, AIDA<br>Baud rate [Mbps] 100<br>Protocol PROFINET RT<br>PROFINET IRT<br>Max. address capacity Inputs [byte] 64<br>Outputs [byte] 64<br>LED displays (bus-specific) M/P = Maintenance/PROFIenergy<br>NF = Network fault<br>TP1 = Network active port 1<br>TP2 = Network active port 2<br>(product-specific) M = Modify, parameterisation<br>PL = Load supply<br>PS = Electronic supply, sensor supply<br>SF = System fault<br>Device-specific diagnostics • Channel and module-oriented diagnostics<br>• Undervoltage of modules<br>• Diagnostic memory<br>Configuration support GSDML file<br>Parameterisation • System parameters<br>• Diagnostic behaviour<br>• Signal setup<br>• Fail-safe response<br>• Forcing of channels<br>Additional functions • Start-up parameterisation in plain text via fieldbus<br>• Fast start-up (FSU)<br>• Channel-oriented diagnostics via fieldbus<br>• Acyclic data access via fieldbus and via Ethernet<br>• System status can be displayed using process data<br>• Additional diagnostic interface for operator unit<br>• I&M, LLDP, MRP, MRPD, MQTT, PROFIsafe, PROFIenergy, S2 system redundancy<br>Control elements • DIL switch<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Intrinsic current consumption at nominal operating voltage [mA] Typically 70<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] – 5... +50<br>Storage/transport [°C] –20 ... +70<br>Certification RCM<br>Housing material Die-cast aluminium<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 80<br>Product weight [g] 280<br>**----- End of picture text -----**<br> ## - **Note** H- Please observe the general limits and guidelines for the system when configuring the electrical modules. ## - **Note** H- Always use the correct screws for the interlinking block; this depends on whether the block is made of metal or plastic: • Self-tapping screws for plastic • Screws with metric thread for interlinking blocks metal interlinking blocks 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 71 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – PROFINET bus node, push-pull RJ45 ## **Connection and display components** |1|2<br>3<br>[1] Bus-specifc status LEDs<br>[2] CPX-P-specifc status LEDs<br>[3] Fieldbus interface (RJ45 socket,<br>8-pin)<br>[4] DIL switch (under cover)| |---|---| |4<br>3|| ||| ## **Pin allocation for the fieldbus interface** **==> picture [524 x 123] intentionally omitted <==** **----- Start of picture text -----**<br> Terminal allocation Pin Signal Designation<br>RJ45 socket<br>1 TD+ Transmitted data+<br>2 TD- Transmitted data-<br>3 RD+ Received data+<br>4 n.c. Not connected<br>5 n.c. Not connected<br>6 RD- Received data-<br>7 n.c. Not connected<br>8 n.c. Not connected<br>Housing Shielding Shielding<br>**----- End of picture text -----**<br> Subject to change – 2023/10 72 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – PROFINET bus node, push-pull RJ45 **==> picture [523 x 376] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Bus node<br>PROFINET bus node • I&M 8110370 CPX-M-FB44<br>• LLDP<br>• MRP<br>• MRPD<br>• PROFIenergy<br>• S2 system redundancy<br>Bus connection<br>RJ45 plug, 8-pin, push-pull 552000 FBS-RJ45-PP-GS<br>Cover cap for bus connection 548753 CPX-M-AK-C<br>Cover cap for bus connection 2873540 CPX-M-AK-D<br>Cover for DIL switch 548754 CPX-M-AK-M<br>User documentation<br>Electronics manual, CPX bus node German 548759 CPX-(M)-FB33_35/43_45-DE<br>English 548760 CPX-(M)-FB33_35/43_45-EN<br>Spanish 548761 CPX-(M)-FB33_35/43_45-ES<br>French 548762 CPX-(M)-FB33_35/43_45-FR<br>Italian 548763 CPX-(M)-FB33_35/43_45-IT<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 73 d **Internet: www.festo.com/catalogue/...** ## Terminal CPX-P ## Data sheet – PROFINET bus node, push-pull SCRJ Bus node for operating the CPX-P terminal on PROFINET. The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules. The status of the CPX-P terminal is displayed as a common message via 4 CPX-P-specific LEDs. The fieldbus communication status is displayed via three bus-specific LEDs. ## **Application** Bus connection The bus connection is established via SCRJ push-pull sockets to IEC 6175424 (fibre-optic cable, AIDA standard) with degree of protection IP65, IP67. The connections on the bus node are equivalent 100BaseFX Ethernet ports that are brought together via an internal switch. Fibre-optic cables made from plastic (POF, 980/1000 μm) are also suitable for transmission. - Maximum segment length 50 m - Transmission rate 100 Mbps - Supports LLDP and SNMP ## PROFINET implementation The bus node supports the PROFINET protocol on the basis of the Ethernet standard and TCP/IP technology to IEEE802.3. This guarantees a data exchange with a high data transmission rate, for example I/O data from sensors, actuators or robot controllers, PLCs or process equipment. In addition, non-real-time critical information such as diagnostic information, configuration information, etc. can be transferred. The Ethernet bandwidth is sufficient to transfer both data types (real-time and non-real-time) in parallel. The bus node features LEDs for bus status and CPX-P peripheral information as well as switch elements and a diagnostic interface. PROFINET provides the user with access to all peripherals, diagnostic and parameter data of the CPX-P terminal. The bus node can be used as a remote I/O or remote controller. All information rele- vant to the CPX-P can be read out and, depending on the function, changed via the diagnostic interface. ## Points to note in connection with CPX-CEC When a bus node is combined with a control block (CPX-CEC, in the fieldbus remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX-P control block. In this case, the bus node only provides the communication interface to the PLC. Communication between the control block and CPX-P bus node takes place by interlinking the CPX-P modules and takes up the following address capacity in the CPX-P system: - 8/16 byte outputs - 8/16 byte inputs The following address capacity remains in the control block or CPX system for activating the peripherals: - 56/48 byte inputs - 56/48 byte outputs 74 d **Internet: www.festo.com/catalogue/...** Subject to change – 2023/10 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – PROFINET bus node, push-pull SCRJ **==> picture [523 x 566] intentionally omitted <==** **----- Start of picture text -----**<br> General technical data<br>Type CPX-M-FB45<br>Fieldbus interface 2x SCRJ push-pull socket, AIDA<br>Baud rate [Mbps] 100<br>Protocol PROFINET RT<br>PROFINET IRT<br>Max. address capacity Inputs [byte] 64<br>Outputs [byte] 64<br>LED displays (bus-specific) M/P = Maintenance/PROFIenergy<br>NF = Network fault<br>TP1 = Network active port 1<br>TP2 = Network active port 2<br>(product-specific) M = Modify, parameterisation<br>PL = Load supply<br>PS = Electronic supply, sensor supply<br>SF = System fault<br>Device-specific diagnostics • Channel and module-oriented diagnostics<br>• Undervoltage of modules<br>• Diagnostic memory<br>Configuration support GSDML file<br>Parameterisation • System parameters<br>• Diagnostic behaviour<br>• Signal setup<br>• Fail-safe response<br>• Forcing of channels<br>Additional functions • Start-up parameterisation in plain text via fieldbus<br>• Fast start-up (FSU)<br>• Channel-oriented diagnostics via fieldbus<br>• Acyclic data access via fieldbus and via Ethernet<br>• System status can be displayed using process data<br>• Additional diagnostic interface for operator unit<br>• I&M<br>• LLDP<br>• MRP<br>• MRPD<br>• MQTT<br>• PROFIsafe<br>• PROFIenergy<br>• S2 system redundancy<br>Control elements DIL switch<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Intrinsic current consumption at nominal operating voltage [mA] Typically 145<br>Certification RCM<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] – 5... +50<br>Storage/transport [°C] –20 ... +70<br>Housing material Die-cast aluminium<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 80<br>Product weight [g] 280<br>**----- End of picture text -----**<br> ## - **Note** H- Please observe the general limits and guidelines for the system when configuring the electrical modules. ## - **Note** H- Always use the correct screws for the interlinking block; this depends on whether the block is made of metal or plastic: - Self-tapping screws for plastic • Screws with metric thread for interlinking blocks metal interlinking blocks 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 75 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – PROFINET bus node, push-pull SCRJ ## **Connection and display components** |1|2<br>3<br>[1] Bus-specifc status LEDs<br>[2] CPX-P-specifc status LEDs<br>[3] Fieldbus interface (SCRJ socket,<br>2-pin)<br>[4] DIL switch (under cover)| |---|---| |4<br>3|| ||| |**Pin allocation for the feldbus interface**<br>Terminal allocation|**Pin allocation for the feldbus interface**<br>Terminal allocation|Pin<br>Signal<br>Designation|Pin<br>Signal<br>Designation|Pin<br>Signal<br>Designation| |---|---|---|---|---| |**SCRJ socket**||||| |||1|TX|Outgoing| |||2|Rx|Incoming| Subject to change – 2023/10 76 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – PROFINET bus node, push-pull SCRJ **==> picture [523 x 388] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Bus node<br>2x SCRJ push-pull socket, AIDA • I&M 8110371 CPX-M-FB45<br>• LLDP<br>• MRP<br>• MRPD<br>• PROFIenergy<br>• S2 system redundancy<br>Bus connection<br>SCRJ plug, 2-pin, push-pull 571017 FBS-SCRJ-PP-GS<br>Cover cap for bus connection 548753 CPX-M-AK-C<br>Cover cap for bus connection 2873540 CPX-M-AK-D<br>Cover for DIL switch 548754 CPX-M-AK-M<br>User documentation<br>Electronics manual, CPX-P bus node German 548759 CPX-(M)-FB33_35/43_45-DE<br>English 548760 CPX-(M)-FB33_35/43_45-EN<br>Spanish 548761 CPX-(M)-FB33_35/43_45-ES<br>French 548762 CPX-(M)-FB33_35/43_45-FR<br>Italian 548763 CPX-(M)-FB33_35/43_45-IT<br>Software<br>Adapter M12, 5-pin to mini USB socket, and controller software 547432 NEFC-M12G5-0.3-U1G5<br>**----- End of picture text -----**<br> 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 77 Terminal CPX-P ## Data sheet – EtherNet/IP bus node - Industrial Ethernet Bus node for handling communication • EtherNet/IP between the electrical terminal CPX-P • Web and the EtherNet/IP network. The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules. The status of the CPX-P terminal is displayed as a common message via 4 CPX-P-specific LEDs. ## **Application** ## Bus connection The bus connection is established via EtherNet/IP is an open bus system an M12 plug, D-coded to IEC 947-5-2 based on the Ethernet standard and with degree of protection IP65, IP67. TCP/IP technology (IEEE802.3). ## EtherNet/IP implementation The CPX-FB36 supports the two directly controlled by the EtherNet/IP operating modes: remote I/O and master (host). remote controller. In addition to activation via a bus sysIn remote I/O operating mode, all tem, it is possible to use IT technolofunctions of the CPX-P terminal are gies. An integrated web server enables diagnostic data to be visualised via HTML. Various programs support direct conforms to DIN EN 50173/CAT 5 as an access to the device data from the auintegrated interface. tomation network. The EtherNet/IP node for CPX-P supports the transmission technology that ## Points to note in connection with CPX-CEC When a bus node is combined with a control block (CPX-CEC, in the fieldbus remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX-P control block. In this case, the bus node only provides the communication interface to the PLC. Communication between the control block and CPX-P bus node takes place by interlinking the CPX-P modules and takes up the following address capacity in the CPX-P system: - 8 byte outputs • 8 byte inputs The following address capacity remains in the control block or CPX system for activating the peripherals: - 56 byte inputs • 56 byte outputs Subject to change – 2023/10 78 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – EtherNet/IP bus node ## **General technical data** **==> picture [523 x 461] intentionally omitted <==** **----- Start of picture text -----**<br> Type CPX-FB36<br>Fieldbus interface 2x M12x1 socket, 4-pin, D-coded<br>Baud rate [Mbps] 10/100<br>Protocol EtherNet/IP<br>Modbus TCP<br>Max. address capacity, inputs [byte] 64<br>Max. address volume for outputs [byte] 64<br>LED displays (bus-specific) MS = Module status<br>NS = network status<br>TP1 = Network active port 1<br>TP2 = Network active port 2<br>Device-specific diagnostics • Module and channel-oriented diagnostics<br>• Undervoltage of modules<br>• Diagnostic memory<br>Configuration support • EDS file<br>• L5K export with CPX-FMT<br>Parameterisation • Diagnostic behaviour<br>• Fail-safe response<br>• Forcing of channels<br>• Idle mode characteristics<br>• Signal setup<br>• System parameters<br>Additional functions • EtherNet/IP Quickconnect<br>• Ring topology (DLR)<br>• Acyclic data access via "Explicit Message" and Ethernet<br>• Integrated switch<br>• IP addressing via DHCP, DIL switch or operator unit<br>• Channel-oriented diagnostics via fieldbus<br>• Start-up parameterisation in plain text via fieldbus<br>• System status can be displayed using process data<br>• Additional diagnostic interface for operator units<br>Control elements DIL switch<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Current consumption at nominal voltage [mA] Typically 100<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] –5... +50<br>Storage/transport [°C] –20 ... +70<br>Materials PA-reinforced<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 125<br>**----- End of picture text -----**<br> ## - **Note** H- Please observe the general limits and guidelines for the system when configuring the electrical modules. 2023/10 – Subject to change 79 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – EtherNet/IP bus node ## **Connection and display components** |1||2| |---|---|---| |4||3| |||| |||3| |||| |||| - [1] Bus-specific status LEDs [2] CPX-P-specific status LEDs [3] Fieldbus interface (M12 socket, 4-pin, D-coded) - [4] Transparent DIL switch cover |**Pin allocation for the feldbus interface**<br>Terminal allocation|Pin<br>Signal<br>Designation|Pin<br>Signal<br>Designation|Pin<br>Signal<br>Designation| |---|---|---|---| |**Socket M12, D-coded**|||| ||1|TD+|Transmitted data+| ||2|RD+|Received data+| ||3|TD-|Transmitted data-| ||4|RD-|Received data-| ||Housing|FE|Shielding| Subject to change – 2023/10 80 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – EtherNet/IP bus node **==> picture [523 x 477] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Bus node<br>EtherNet/IP bus node 1912451 CPX-FB36<br>Bus connection<br>Plug M12x1, 4-pin, D-coded 543109 NECU-M-S-D12G4-C2-ET<br>Connecting cable, Straight plug, M12x1, 4-pin, D-coded 0.5 m 8040446 NEBC-D12G4-ES-0.5-S-D12G4-ET<br>straight plug, M12x1, 1 m 8040447 NEBC-D12G4-ES-1-S-D12G4-ET<br>4-pin, D-coded 3 m 8040448 NEBC-D12G4-ES-3-S-D12G4-ET<br>5 m 8040449 NEBC-D12G4-ES-5-S-D12G4-ET<br>10 m 8040450 NEBC-D12G4-ES-10-S-D12G4-ET<br>Straight plug, RJ45, 8-pin 1 m 8040451 NEBC-D12G4-ES-1-S-R3G4-ET<br>3 m 8040452 NEBC-D12G4-ES-3-S-R3G4-ET<br>5 m 8040453 NEBC-D12G4-ES-5-S-R3G4-ET<br>10 m 8040454 NEBC-D12G4-ES-10-S-R3G4-ET<br>Open end, 4-wire 5 m 8040456 NEBC-LE4-ES-5-D12G4-ET<br>Inspection cover, transparent 533334 AK-SUB-9/15-B<br>Inscription label holder for connection block 536593 CPX-ST-1<br>User documentation<br>User documentation for bus node CPX-FB36 German 8024074 CPX-FB36-DE<br>English 8024075 CPX-FB36-EN<br>Spanish 8024076 CPX-FB36-ES<br>French 8024077 CPX-FB36-FR<br>Italian 8024078 CPX-FB36-IT<br>Chinese 8024079 CPX-FB36-ZH<br>Software<br>Adapter M12, 5-pin to mini USB socket, and controller software 547432 NEFC-M12G5-0.3-U1G5<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 81 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – EtherCAT bus node Bus node for operating the CPX-P terminal on EtherCAT. The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules. The status of the CPX-P terminal is displayed as a common message via 4 CPX-P-specific LEDs. The fieldbus communication status is displayed via 4 bus-specific LEDs. ## **Application** Bus connection The bus connection is established via two sockets M12x1, D-coded to IEC 61076-2-101 with degree of protection IP65, IP67. Both connections are equivalent 100BaseTX Ethernet ports with integrated auto MDI functionality (crossover and patch cable can be used) that are brought together via an • Maximum segment length 100 m internal switch. • Transmission rate 100 Mbps - Maximum segment length 100 m ## EtherCAT implementation The CPX-FB37 supports the EtherCAT protocol on the basis of the Ethernet standard and TCP/IP technology to IEEE802.3. This guarantees a data exchange with a high data transmission rate, for example I/O data from sensors, actuators or robot controllers, PLCs or process equipment. In addition, non-real-time critical information such as diagnostic information, configuration information, etc. can be transferred. The data bandwidth is sufficient to transfer both data types (real-time and non-real-time) in parallel. The bus node features LEDs for bus status and CPX-P peripheral information as well as switch elements and a diagnostic interface. The bus node can be used as a remote I/O or remote controller. All information relevant to the CPX-P can be read out and, depending on the function, changed via the diagnostic interface. The functions MDP (modular device profile) and CoE (CAN over EtherCAT) enable easy access to parameters and diagnostic data via EtherCAT. Specific EtherCAT functions: - Specific EtherCAT functions: • DC (distributed clocks), • CoE (parameters and diagnostics or time-synchronised data fail-safe mode): all module transmission parameters can be set - FoE (file over EtherCAT) makes it possible to download firmware easily - EoE (Ethernet over EtherCAT): diagnostic data can be retrieved easily using a browser - MDP (modular device profile): easy configuration using a module selection box - Hot connect, easy replacement of an EtherCAT CPX-P terminal ## Points to note in connection with CPX-CEC When a bus node is combined with a control block (CPX-CEC, in the fieldbus remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX-P control block. In this case, the bus node only provides the communication interface to the PLC. Communication between the control block and CPX-P bus node takes place by interlinking the CPX-P modules and takes up the following address capacity in the CPX-P system: - 8/16 byte outputs - 8/16 byte inputs The following address capacity remains in the control block or CPX system for activating the peripherals: - 56/48 byte inputs - 56/48 byte outputs Subject to change – 2023/10 82 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – EtherCAT bus node ## **General technical data** **==> picture [523 x 461] intentionally omitted <==** **----- Start of picture text -----**<br> Type CPX-FB37<br>Fieldbus interface 2x M12x1 socket, 4-pin, D-coded<br>Baud rate [Mbps] 100<br>Protocol EtherCAT<br>Max. address capacity Inputs [byte] 64<br>Outputs [byte] 64<br>LED displays Bus-specific Error = Communication error<br>L/A1 = Network active port 1<br>L/A2 = Network active port 2<br>Run = Communication status<br>Product-specific M = Modify, parameterisation<br>PL = Load supply<br>PS = Electronic supply, sensor supply<br>SF = System fault<br>Device-specific diagnostics • Channel and module-oriented diagnostics<br>• Undervoltage of modules<br>• Diagnostic memory<br>Configuration support ESI file<br>Parameterisation • System parameters<br>• Diagnostic behaviour<br>• Signal setup<br>• Fail-safe response<br>• Forcing of channels<br>Additional functions • System status can be displayed using process data<br>• Additional diagnostic interface for operator units<br>• Emergency message<br>• Acyclic data access via fieldbus<br>• Diagnostics object<br>• Compatibility mode with CPX-FB38<br>• Modular device profile (MDP)<br>• Variable PDO mapping<br>Control elements DIL switch<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Current consumption [mA] Typically 100<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] –5... +50<br>Storage/transport [°C] –20 ... +70<br>Materials Housing PA-reinforced<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 125<br>**----- End of picture text -----**<br> ## - **Note** H- Please observe the general limits and guidelines for the system when configuring the electrical modules. ## - **Note** H- Always use the correct screws for the • Self-tapping screws for plastic interlinking block; this depends on interlinking blocks whether the block is made of metal or plastic: - Screws with metric thread for metal interlinking blocks 2023/10 – Subject to change 83 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – EtherCAT bus node ## **Connection and display components** |1|2<br>3<br>4| |---|---| |5|| - [1] Bus-specific status LEDs - [2] CPX-P-specific status LEDs - [3] Fieldbus interface, input (socket M12x1, 4-pin, D-coded) - [4] Fieldbus interface, output (socket M12x1, 4-pin, D-coded) - [5] DIL switch ## **Pin allocation for the fieldbus interface** **==> picture [524 x 82] intentionally omitted <==** **----- Start of picture text -----**<br> Terminal allocation Pin Signal Designation<br>M12x1 socket, D-coded<br>1 TD+ Transmitted data+<br>2 RD+ Received data+<br>3 TD- Transmitted data-<br>4 RD- Received data-<br>Housing FE Shielding<br>**----- End of picture text -----**<br> Subject to change – 2023/10 84 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – EtherCAT bus node **==> picture [523 x 501] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Bus node<br>EtherCAT bus node 2735960 CPX-FB37<br>Bus connection<br>Plug M12x1, 4-pin, D-coded 543109 NECU-M-S-D12G4-C2-ET<br>Connecting cable, Straight plug, M12x1, 4-pin, D-coded 0.5 m 8040446 NEBC-D12G4-ES-0.5-S-D12G4-ET<br>straight plug, M12x1, 1 m 8040447 NEBC-D12G4-ES-1-S-D12G4-ET<br>4-pin, D-coded 3 m 8040448 NEBC-D12G4-ES-3-S-D12G4-ET<br>5 m 8040449 NEBC-D12G4-ES-5-S-D12G4-ET<br>10 m 8040450 NEBC-D12G4-ES-10-S-D12G4-ET<br>Straight plug, RJ45, 8-pin 1 m 8040451 NEBC-D12G4-ES-1-S-R3G4-ET<br>3 m 8040452 NEBC-D12G4-ES-3-S-R3G4-ET<br>5 m 8040453 NEBC-D12G4-ES-5-S-R3G4-ET<br>10 m 8040454 NEBC-D12G4-ES-10-S-R3G4-ET<br>Open end, 4-wire 5 m 8040456 NEBC-LE4-ES-5-D12G4-ET<br>Inspection cover, transparent 533334 AK-SUB-9/15-B<br>Cover cap for sealing unused bus connections (10 pieces) 165592 ISK-M12<br>Inscription label holder for connection block 536593 CPX-ST-1<br>User documentation<br>Electronics manual, CPX-P bus node, type CPX-FB37 German 8029674 P.BE-CPX-FB37-DE<br>English 8029675 P.BE-CPX-FB37-EN<br>Spanish 8029676 P.BE-CPX-FB37-ES<br>French 8029677 P.BE-CPX-FB37-FR<br>Italian 8029678 P.BE-CPX-FB37-IT<br>Chinese 8029679 P.BE-CPX-FB37-ZH<br>Software<br>Adapter M12, 5-pin to mini USB socket, and controller software 547432 NEFC-M12G5-0.3-U1G5<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 85 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – I-Port interface **==> picture [30 x 14] intentionally omitted <==** **----- Start of picture text -----**<br> 3G 3G 3G 3G 5J 5J 5J 5J<br>12/14 82/84<br>11 3/5<br>1<br>**----- End of picture text -----**<br> The electrical interface CPX-P CTEL master establishes the connection to modules of the CTEL/CTEU series that have an I-Port interface (device). The I/O data from the connected devices are transmitted to the connected CPX-P bus node and thus to the higher-order controller via fieldbus. A maximum of 4 devices can be connected to a CPX-P CTEL master via suitable M12 interfaces. ## **Application** I-Port interface As well as transmitting the communication data, the I-Port interfaces of a CPX-P CTEL master also transmit the power supply to the connected sensors and the load supply to the valves (or outputs). Both circuits are supplied separately with 24 V, using a separate reference potential. The connecting cables with a dual function as signal cable and supply cable must meet the corresponding increased requirements. ## **Configuration example – CPX-P CTEL master with CTEL modules** **==> picture [53 x 47] intentionally omitted <==** **----- Start of picture text -----**<br> — EO<br>PNew) ep<br>aa:<br>12/14 82/84<br>11 3/5<br>1<br>3G 3G 3G 3G 5J 5J 5J 5J<br>**----- End of picture text -----**<br> The CPX-P CTEL master provides 4 external I-Port interfaces, each of which can be connected to a device. I-Port is an interface for exchanging serial data for connecting decentralised modules or valve terminals from Festo. The I-Port interface is based on IO-Link and is compatible with it in certain areas. The connection type corresponds to a star topology. In other words, only one module or valve terminal can be connected to each I-Port. The limitations with respect to IO-Link include: - Permanently set baud rate of 230.4 kbps - SIO mode is not supported - Max. 32 bytes of input data and 32 bytes of output data - Only one dump of the master commands is used - Configuration via IODD is not supported. Subject to change – 2023/10 86 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – I-Port interface ## **Implementation** The CPX-P CTEL master from Festo enaThe following device variants are The decentralised arrangement of the bles modules with an I-Port interface available: modules and valve terminals with to be connected to a CPX-P system: • Input modules with 16 digital I-Port enables them to be mounted • Max. 4 devices with individual inputs (connection technology M8 close to the cylinders and actuators or electronic protection 3-pin and M12 5-pin) sensors to be controlled. This means • Max. 64 inputs/64 outputs per • Valve terminals with I-Port interface that the compressed air supply lines I-Port interface (up to 48 solenoid coils, different and sensor connecting cables used • The maximum length of a string is valve functions) can be shortened, and it may be 20 m. possible to use smaller valves, thereby saving costs. **Configuration** Settings Manual configuration The precise number of the I/O bytes In the case of manual configuration The process image then always has the made available depends on the re(tool change mode), the volume of insame scope, regardless of the quirements of the connected devices puts and outputs in the process image connected devices. or of the suitable selected operating of the CPX-P system or of the The I/O length specified always applies mode. higher-order fieldbus can be defined to all four I-Ports (max. 8 bytes per The operating mode or preset configumanually using the DIL switches. I-Port). The operating mode or preset configuration of the CPX-P CTEL master can be specified by the user. Several CPX-P CTEL masters can be combined in one CPX-P terminal, depending on the address capacity of the bus node. Example: - CPX-FB13 (512 I/O) - A maximum of 2 CPX-P CTEL masters is possible (each with 256 I/O) ## Automatic configuration In the case of automatic configuration, the I/O length for each I-Port is determined individually and this derived value is used to select the appropriate or next highest configuration preset. Selecting the operating mode and setting the manual configuration takes place via the DIL switches. These DIL switches are not required during continuous operation and are only accessible in the disassembled state. ## **Power supply for I-Port devices** The CPX-P CTEL master provides two separate power supplies for the connected devices: The CPX-P CTEL master provides two The power supply for the devices and The interlinking block with additional disconnected separately without separate power supplies for the the inputs is provided by the power supply ensures a separate supply voltdisconnecting the devices. connected devices: supply for the electronics and sensors age for the valves and outputs. This • For operating the device and the of the CPX-P terminal. means it is possible to disconnect this inputs connected to it The power supply for the outputs and supply voltage separately. • For the outputs and valves that are valves is provided by the power supply The valves and outputs of the connectconnected to the device for the valves of the CPX-P terminal. ed I-Port devices can therefore be 2023/10 – Subject to change 87 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – I-Port interface ## **General technical data** **==> picture [524 x 433] intentionally omitted <==** **----- Start of picture text -----**<br> Type CPX-CTEL-4-M12-5POL<br>Protocol I-Port<br>Max. address capacity Outputs [bit] 256<br>Inputs [bit] 256<br>I-Port connection 4x socket M12, 5-pin, A-coded<br>Number of I-Port interfaces 4<br>Maximum cable length [m] 20<br>Internal cycle time [ms] 1 per 8 bits of user data<br>Galvanic isolation Channel – channel No<br>Channel – internal bus Yes, with intermediate supply<br>LED displays X1 ... 4 = Status of the I-Port interface 1 ... 4<br>PS = Electronic supply<br>PL = Load supply<br>- P - = Module error<br>Diagnostics • Communication error<br>• Module short circuit<br>• Module-oriented diagnostics<br>• Undervoltage<br>Parameterisation • Diagnostic behaviour<br>• Failsafe per channel<br>• Forcing per channel<br>• Idle mode per channel<br>• Module parameters<br>• Tool change mode<br>Additional functions Tool change mode<br>Control elements DIL switch<br>Operating voltage Nominal value [V DC] 24 (reverse polarity protected)<br>Permissible range [V DC] 18 ... 30<br>Power failure buffering [ms] 10<br>Intrinsic current consumption at nominal operating voltage [mA] Typically 65<br>Max. power supply per channel [A] 4x 1.6<br>Max. residual current of outputs per channel [A] 4x 1.6<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Materials PA-reinforced, PC<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 55<br>Product weight [g] 110<br>**----- End of picture text -----**<br> ## - **Note** H- Please observe the general limits and guidelines for the system when configuring the electrical modules. Subject to change – 2023/10 88 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – I-Port interface |**Connection and display components**|**Connection and display components**|**Connection and display components**|**Connection and display components**|**Connection and display components**|**Connection and display components**|**Connection and display components**| |---|---|---|---|---|---|---| |1||||||2<br>4<br>[1] Status LEDs for I-Port interfaces<br>[2] CPX-P-specifc status LEDs<br>[3] Holders for inscription labels<br>(IBS 6x10)<br>[4] I-Port interfaces for up to<br>4 devices| |3||||||| |||||||| |||||||| |||||||| |||||||| |||||||| ## **Combinations of bus nodes/control blocks with interface CPX-CTEL** **==> picture [523 x 261] intentionally omitted <==** **----- Start of picture text -----**<br> Bus node/control block Part no. Interface<br>CPX-CTEL-4-M12-5POL<br>CPX-CEC-C1-V3 3473128 h<br>CPX-CEC-M1-V3 3472765 h<br>CPX-CEC-S1-V3 3472425 h<br>CPX-FB11 526172 h<br>CPX-FB13 195740 h<br>CPX-FB14 526174 h<br>CPX-FB36 1912451 h<br>CPX-FB37 2735960 h<br>CPX-FB43 8110369 h<br>CPX-M-FB44 8110370 h<br>CPX-M-FB45 8110371 h<br>Pin allocation – I-Port interface<br>Terminal allocation Pin Signal Designation<br>1 24 VSEN 24 V DC supply voltage for electronics and inputs<br>2 24 VVAL 24 V DC load voltage supply for valves and outputs<br>3 0 VSEN 0 V DC supply voltage for electronics and sensors<br>4 C/Q I-Port Communication signal C/Q, data transmission line<br>5 0 VVALVES 0 V DC load voltage supply for valves and outputs<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 89 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** Data sheet – I-Port interface **==> picture [522 x 286] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions Download CAD data a www.festo.com<br>Type B1 B2 B3 H1 L1<br>CPX-CTEL-4-M12-5POL 108.1 118.9 124.9 55.1 50<br>**----- End of picture text -----**<br> Subject to change – 2023/10 90 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – I-Port interface **==> picture [523 x 377] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>CPX-P CTEL master<br>Interface for a maximum of 4 I/O modules and valve terminals with I-Port interface (devices) 1577012 CPX-CTEL-4-M12-5POL<br>Bus connection<br>Cover cap M12 165592 ISK-M12<br>Connecting cable Cable characteristic: standard 0.5 m 8003617 NEBU-M12G5-K-0.5-M12W5<br>M12-M12, 5-pin<br>• Straight socket 2 m 8003618 NEBU-M12G5-K-2-M12W5<br>• Angled plug<br>Connecting cable Cable characteristic: standard 0.5 m 570733 NEBU-M12W5-K-0.5-M12W5<br>M12-M12, 5-pin<br>• Angled socket 2 m 570734 NEBU-M12W5-K-2-M12W5<br>• Angled plug<br>Connecting cable Cable characteristic: suitable for use with energy 5 m 574321 NEBU-M12G5-E-5-Q8N-M12G5<br>M12-M12, 5-pin chains 7.5 m 574322 NEBU-M12G5-E-7.5-Q8N-M12G5<br>• Straight socket<br>• Straight plug 10 m 574323 NEBU-M12G5-E-10-Q8N-M12G5<br>Inscription label holder for connection block 536593 CPX-ST-1<br>User documentation<br>User documentation CPX-P CTEL master German 574600 P.BE-CPX-CTEL-DE<br>English 574601 P.BE-CPX-CTEL-EN<br>Spanish 574602 P.BE-CPX-CTEL-ES<br>French 574603 P.BE-CPX-CTEL-FR<br>Italian 574604 P.BE-CPX-CTEL-IT<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 91 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – IO-Link interface The electrical interface CPX-CTEL-2-... enables the connection of modules with IO-Link interface (IO-Link device) to the CPX-P terminal. The I/O data from the connected devices are transmitted to the connected CPX-P bus node and thus to the higher-order controller via fieldbus. A maximum of two IO-Link devices can be connected to an electrical interface CPX-CTEL-2-... via the suitable M12 interfaces. ## **Application** ## IO-Link interface The communication system IO-Link is used to exchange serial data from decentralised function modules (devices) at the field level. The electrical interface CPX-CTEL-2-... provides two external IO-Link interfaces, each of which can be connected to a device. The connection type corresponds to a star topology, which means that only one device can be connected to each port. The address space that the module makes available and assigns accordingly in the CPX-P system can be configured according to various presettings. Selecting the operating mode and setting the manual configuration takes place via the DIL switches. These DIL switches are not required during continuous operation and are only accessible in the disassembled state. ## Restrictions The interfaces (ports) of electrical interface CPX-CTEL-2-... support the connection of IO-Link devices with few limitations. - The process data length of the inputs and outputs is limited to 16 bytes each per port - The driver strength on the C/Q line is limited to 250 mA - SIO mode is not supported ## Power supply for devices The electrical interface CPX-CTEL-2-... provides two separate power supplies for the connected devices: - For operating the device and the inputs connected to it - For the outputs and valves that are connected to the device - The power supply for the devices and the inputs is provided by the power supply for the electronics and sensors of the CPX-P terminal. The power supply for the outputs and valves is provided by the power supply for the valves of the CPX-P terminal. The interlinking block with additional supply ensures a separate supply voltage for the valves and outputs. This means it is possible to disconnect this supply voltage separately. The valves and outputs of the connected I-Port devices can therefore be disconnected separately without disconnecting the devices. Subject to change – 2023/10 92 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – IO-Link interface ## **General technical data** **==> picture [523 x 423] intentionally omitted <==** **----- Start of picture text -----**<br> Type CPX-CTEL-2-M12-5POL-LK<br>Protocol IO-Link, master version V 1.0<br>Max. address capacity Outputs [bit] 256<br>Inputs [bit] 256<br>I-Port connection 2x socket M12, 5-pin, A-coded<br>Number of IO-Link interfaces 2<br>Maximum cable length [m] 20<br>Internal cycle time [ms] 1 per 8 bits of user data<br>Galvanic isolation Channel – channel No<br>Channel – internal bus Yes, with intermediate supply<br>LED displays X1 ... 2 = Status of the IO-Link interface 1 ... 2<br>PS = Electronic supply<br>PL = Load supply<br>- P - = Module error<br>Diagnostics • Communication error<br>• Module short circuit<br>• Module-oriented diagnostics<br>• Undervoltage<br>Parameterisation • Diagnostic behaviour<br>• Failsafe per channel<br>• Forcing per channel<br>• Idle mode per channel<br>• Module parameters<br>Additional functions –<br>Control elements DIL switch<br>Operating voltage Nominal value [V DC] 24 (reverse polarity protected)<br>Permissible range [V DC] 18 ... 30<br>Power failure buffering [ms] 10<br>Intrinsic current consumption at nominal operating voltage [mA] Typically 65<br>Max. power supply per channel [A] 2x 1.6<br>Max. residual current of outputs per channel [A] 2x 1.6<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Materials PA-reinforced, PC<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block) W x L x H [mm] 50 x 107 x 55<br>Product weight [g] 110<br>**----- End of picture text -----**<br> ## - **Note** H- Please observe the general limits and guidelines for the system when configuring the electrical modules. 2023/10 – Subject to change 93 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – IO-Link interface **==> picture [523 x 171] intentionally omitted <==** **----- Start of picture text -----**<br> Connection and display components<br>1 2 [1] Status LEDs for I-Port interfaces<br>[2] CPX-P-specific status LEDs<br>[3] Holders for inscription labels<br>(IBS 6x10)<br>4 [4] IO-Link interfaces for up to<br>2 devices<br>[5] Unused connections<br>5<br>3<br>**----- End of picture text -----**<br> ## **Combinations of bus nodes/control blocks with interface CPX-CTEL-2** |**Combinations of bus nodes/control blocks with interface CPX-CTEL-2**|**Combinations of bus nodes/control blocks with interface CPX-CTEL-2**|**Combinations of bus nodes/control blocks with interface CPX-CTEL-2**| |---|---|---| |Bus node/control block<br>CPX-CEC-C1-V3|Part no.<br>**3473128**|Interface| |||CPX-CTEL-2-M12-5POL-LK<br>h| |CPX-CEC-M1-V3|**3472765**|h| |CPX-CEC-S1-V3|**3472425**|h| |CPX-FB36|**1912451**|h| |CPX-FB43|**8110369**|h| |CPX-M-FB44|**8110370**|h| |CPX-M-FB45|**8110371**|h| |**Pin allocation of IO-Lin**<br>Terminal allocation|**k interface**|Pin<br>Signal<br>Designation<br>1<br>24 VSEN<br>24 V DC supplyvoltage for electronics and inputs|Pin<br>Signal<br>Designation<br>1<br>24 VSEN<br>24 V DC supplyvoltage for electronics and inputs|Pin<br>Signal<br>Designation<br>1<br>24 VSEN<br>24 V DC supplyvoltage for electronics and inputs| |---|---|---|---|---| |||||| |||2|24 VVAL|24 V DC load voltage supplyfor valves and outputs| |||3|0 VSEN|0 V DC supplyvoltage for electronics and sensors| |||4|C/QI-Port|Communication signal C/Q, data transmission line| |||5|0 VVALVES|0 V DC load voltage supply for valves and outputs| |||||| Subject to change – 2023/10 94 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – IO-Link interface **==> picture [523 x 286] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions Download CAD data a www.festo.com<br>Type B1 B2 B3 H1 L1<br>CPX-CTEL-2-M12-5POL-LK 108.1 118.9 124.9 55.1 50<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 95 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – IO-Link interface ## **Ordering data** **==> picture [524 x 379] intentionally omitted <==** **----- Start of picture text -----**<br> Designation Part no. Type<br>CPX-P CTEL master, IO-Link<br>Interface for max. 2 I/O modules and valve terminals with IO-Link interface (devices) 2900543 CPX-CTEL-2-M12-5POL-LK<br>Bus connection<br>Cover cap M12 165592 ISK-M12<br>Connecting cable Cable characteristic: standard 0.5 m 8003617 NEBU-M12G5-K-0.5-M12W5<br>M12-M12, 5-pin<br>• Straight socket 2 m 8003618 NEBU-M12G5-K-2-M12W5<br>• Angled plug<br>Connecting cable Cable characteristic: standard 0.5 m 570733 NEBU-M12W5-K-0.5-M12W5<br>M12-M12, 5-pin<br>• Angled socket 2 m 570734 NEBU-M12W5-K-2-M12W5<br>• Angled plug<br>Connecting cable Cable characteristic: suitable for use with energy 5 m 574321 NEBU-M12G5-E-5-Q8N-M12G5<br>M12-M12, 5-pin chains 7.5 m 574322 NEBU-M12G5-E-7.5-Q8N-M12G5<br>• Straight socket<br>• Straight plug 10 m 574323 NEBU-M12G5-E-10-Q8N-M12G5<br>Inscription label holder for connection block 536593 CPX-ST-1<br>User documentation<br>User documentation for CPX-P CTEL master German 8034115 P.BE-CPX-CTEL-LK-DE<br>English 8034116 P.BE-CPX-CTEL-LK-EN<br>Spanish 8034117 P.BE-CPX-CTEL-LK-ES<br>French 8034118 P.BE-CPX-CTEL-LK-FR<br>Italian 8034119 P.BE-CPX-CTEL-LK-IT<br>Swedish 8034120 P.BE-CPX-CTEL-LK-ZH<br>**----- End of picture text -----**<br> Subject to change – 2023/10 96 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – Measuring module for displacement encoder The measuring module CPX-CMIX is inAdvantages: tended exclusively for use in the CPX-P • Pneumatics and electrics – moveterminal. ment and measurement on one If offers movement and measurement platform in one, as an integral component of the • Innovative measurement technology terminal CPX-P – the modular periph– piston rod drives, rodless drives, eral system for decentralised automarotary drives tion tasks. • Actuation via fieldbus The modular design means that valves, • Remote maintenance, remote diagdigital inputs and outputs, positioning nostics, web server, text message modules, end-position controllers and and e-mail alert are all possible via measuring modules, as appropriate to TCP/IP the application, can be combined in • Modules can be quickly exchanged almost any way on the CPX-P terminal. and expanded without altering the wiring |modules, end-position controllers and<br>measuring modules, as appropriate to<br>the application, can be combined in<br>almost any way on the CPX-P terminal.<br>and e-mail alert are all possible via<br>TCP/IP<br>• Modules can be quickly exchanged<br>and expanded without altering the<br>wiring|modules, end-position controllers and<br>measuring modules, as appropriate to<br>the application, can be combined in<br>almost any way on the CPX-P terminal.<br>and e-mail alert are all possible via<br>TCP/IP<br>• Modules can be quickly exchanged<br>and expanded without altering the<br>wiring| |---|---| |**General technical data**|| |**Operating voltage**|| |Operatingvoltage range<br>[V DC]|18 ... 30| |Nominal operatingvoltage<br>[V DC]|24| |Current consumption at nominal operatingvoltage<br>[mA]|80| |Short circuit current rating|Yes| |Power failure buffering<br>[ms]|10| ||| |Number of axis strings|1| |Axesper string|1| |Length of connecting cable to axis<br>[m]|š30| |Max. number of modules|9| |Display|7-segment display| |Assigned addresses<br>Outputs<br>[bit]<br>Inputs<br>[bit]|6x8| ||6x8| |Diagnostics|Channel and module-oriented| ||Via local 7-segment display| ||Undervoltage of modules| ||Undervoltage of measuringsystem| |Status indication|Power load| ||Error| ||| |**Control interface**|| |Data|CAN bus with Festoprotocol| ||Digital| |Electrical connection|5-pin| ||M9| ||Socket| ||| |Materials: Housing|PA-reinforced| |Note on materials|RoHS-compliant| |PWIS conformity|VDMA24364-B2-L| |Product weight<br>[g]|140| |Dimensions<br>Length<br>[mm]<br>Width<br>[mm]<br>Height<br>[mm]|107| ||50| ||55| 2023/10 – Subject to change 97 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Measuring module for displacement encoder **==> picture [524 x 452] intentionally omitted <==** **----- Start of picture text -----**<br> Operating and environmental conditions<br>Ambient temperature [°C] –5 ... +50<br>Storage temperature [°C] –20 ... +70<br>Relative humidity [%] 5 ... 95, non-condensing<br>Degree of protection to IEC 60529 IP65<br>Connection and display components<br>[1] 3-digit display<br>1 3 [2] Control interface<br>[3] Status LEDs<br>[4] Inscription labels<br>4<br>2<br>Pin allocation – Control interface<br>Terminal allocation Pin Signal Designation<br>1 +24 V Nominal operating voltage<br>2 +24 V Load voltage<br>3 0 V Ground<br>4 CAN_H CAN high<br>5 CAN_L CAN low<br>Housing Shielding Cable shielding<br>Permitted bus nodes/CEC<br>Bus node/CEC Protocol Max. number of CMIX modules<br>CPX-CEC... – 9<br>CPX-FB11 DeviceNet [1)] 9<br>CPX-FB13 PROFIBUS [2)] 9<br>CPX-FB14 CANopen 5<br>CPX-FB36 EtherNet/IP 9<br>CPX-FB37 EtherCAT 9<br>CPX-FB43 PROFINET RT, M12 9<br>CPX-M-FB44 PROFINET RT, RJ45 9<br>CPX-M-FB45 PROFINET RT, SCRJ 9<br>**----- End of picture text -----**<br> 1) As of revision 20 (R20) 2) As of revision 23 (R23) PROFIBUS[®] , DeviceNet[®] , CANopen[®] , CC-LINK[®] , EtherCAT[®] , PROFINET[®] , Sercos[®] and EtherNet/IP[®] are registered trademarks of their respective trademark holders in certain countries. Subject to change – 2023/10 98 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Measuring module for displacement encoder **==> picture [523 x 462] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Measuring module<br>Order code in the CPX-P configurator: T2 567417 CPX-CMIX-M1-1<br>Connecting cable<br>Connecting cable M9-M9, 5-pin 0.25 m 540327 KVI-CP-3-WS-WD-0.25<br>• Angled socket 0.5 m 540328 KVI-CP-3-WS-WD-0.5<br>• Angled plug 2 m 540329 KVI-CP-3-WS-WD-2<br>5 m 540330 KVI-CP-3-WS-WD-5<br>8 m 540331 KVI-CP-3-WS-WD-8<br>Connecting cable M9-M9, 5-pin 2 m 540332 KVI-CP-3-GS-GD-2<br>• Straight socket 5 m 540333 KVI-CP-3-GS-GD-5<br>• Straight plug 8 m 540334 KVI-CP-3-GS-GD-8<br>Connecting component M9-M9, 5-pin, for cabinet through-feed 543252 KVI-CP-3-SSD<br>For displacement encoder MME: 2 m 575898 NEBP-M16W6-K-2-M9W5<br>Connection between displacement encoder MME and measuring module<br>CPX-CMIX<br>Screws<br>For mounting on the metal interlinking block 550219 CPX-M-M3X22-4X<br>Inscription labels<br>Inscription labels 6x10, in frames Pack of 64 18576 IBS-6x10<br>User documentation<br>User documentation, measuring module CPX-CMIX [1)] German 567053 P.BE-CPX-CMIX-DE<br>English 567054 P.BE-CPX-CMIX-EN<br>Spanish 567055 P.BE-CPX-CMIX-ES<br>French 567056 P.BE-CPX-CMIX-FR<br>Italian 567057 P.BE-CPX-CMIX-IT<br>**----- End of picture text -----**<br> 1) User documentation in paper form is not included in the scope of delivery PROFIBUS[®] , DeviceNet[®] , CANopen[®] , INTERBUS[®] , CC-LINK[®] , EtherCAT[®] , PROFINET[®] , Sercos[®] and EtherNet/IP[®] are registered trademarks of their respective trademark holders in certain countries. 2023/10 – Subject to change 99 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – Input module, digital, NAMUR ## **Function** ## **Area of application** Digital input modules enable the con• Input modules for 24 V DC sensor nection of up to eight NAMUR sensors supply voltage (or wired mechanical contacts). In • Module features can be parameteraddition, the first four channels can ised alternatively be used as counters or for • The input module receives the supfrequency measurement. ply voltage for the electronics and M12 and terminal strip connection the sensors from the interlinking technology can be used, in either inblock trinsically safe or non-intrinsically safe • Module protection and diagnostics design. through integrated electronic protection in each channel **General technical data** Number of inputs 8 ~~Ee~~ Maximum cable length [m] 200 Input debounce time [ms] 3 (0, 10, 20 parameterisable) Fuse protection (short circuit) Per channel Intrinsic current consumption at nominal operating voltage [mA] Typically 75 Nominal operating voltage [V DC] 24 Permissible voltage fluctuations [%] ±25 Power failure buffering [ms] 20 Residual ripple [Vss] 0.4 Reverse polarity protection For operating voltage Galvanic isolation Channel – channel No ~~———————————~~ Channel – internal bus Yes Input characteristics To EN 60947-5-6 Switching level To EN 60947-5-6 LED displays Group diagnostics 1 Channel diagnostics 8 ~~ee~~ Channel status 8 Diagnostics Wire break per channel Limit value violation per channel Parameterisation error Short circuit per channel Parameterisation Data format Input debounce time per channel Input function per channel Replacement value in diagnostic case per channel Signal extension time per channel Gate time per channel Monitoring of limit values per channel Monitoring of short circuit per channel Monitoring of wire break per channel Monitoring of parameters Lower limit value per channel Upper limit value per channel Counter configuration per channel Control elements DIL switch Additional functions Frequency measurement ~~rr~~ Counter function Degree of protection Depending on the connection block Type of mounting On interlinking block CPX-M-GE.. Grid dimension [mm] 50 Dimensions (including interlinking block and connection block) W x L x H [mm] 50 x 107 x 70 ~~———~~ Product weight [g] 100 ~~==~~ 100 d **Internet: www.festo.com/catalogue/...** Subject to change – 2023/10 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, digital, NAMUR **==> picture [523 x 264] intentionally omitted <==** **----- Start of picture text -----**<br> Explosion protection parameters of the module inputs<br>Type CPX-P-8DE-N CPX-P-8DE-N-IS<br>Maximum output power [mW] – 42<br>Maximum output voltage [V] – 10<br>Maximum output current [mA] – 16.8<br>Maximum external inductance [mH] – 125<br>Maximum external capacitance [μF] – 3<br>Certifications and approvals – Maximum values<br>Type CPX-P-8DE-N CPX-P-8DE-N-IS<br>ATEX category gas – II (1) G<br>Type of ignition protection for gas – [Ex ia Ga] IIC<br>ATEX category for dust – II (1) D<br>Type of ignition protection for dust – [Ex ia Da] IIIC<br>–<br>Explosion protection certification outside the EU EPL Ga (IEC-EX)<br>–<br>EPL Da (IEC-EX)<br>–<br>EPL Gc[Ga] (GB)<br>–<br>EPL Dc[Da] (GB)<br>–<br>EPL Ga (BR)<br>–<br>EPL Da (BR)<br>Explosion-proof ambient temperature [°C] – –5 ≤ Ta ≤ +70<br>Certificate issuing authority – ZELM 12 ATEX 0500 X<br>– IECEx ZLM 12.0007 X<br>– DNV 15.0192 X<br>**----- End of picture text -----**<br> ## - **Note** H- ## - **Note** H- ## - **Note** H- ## - **Note** H- **==> picture [523 x 308] intentionally omitted <==** **----- Start of picture text -----**<br> The module CPX-P-8DE-N-IS has ad- Only the end plate, the pneumatic in- The insulating plate CPX-P-AB-IP The above-mentioned certifications<br>ditional safety measures for possible terface or another module in intrinsi- must be mounted between a module for the module CPX-P-8DE-N-IS do not<br>faults, such as non-resettable fuses, cally safe design are permitted di- in intrinsically safe design apply if the module is used outside<br>to ensure safe operation in accord- rectly to the right of modules in in- (CPX-P-8DE-N-IS) and another, the appropriately configured CPX-P<br>ance with the ignition protection trinsically safe design non-intrinsically safe CPX input or terminal.<br>type. (CPX-P-8DE-N-IS) within the CPX-P output module.<br>If the module is operated within the terminal.<br>permissible parameters, these pro-<br>tective measures will be irrelevant.<br>Materials<br>Housing PA-reinforced<br>PC<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Operating and environmental conditions<br>Type CPX-P-8DE-N CPX-P-8DE-N-IS<br>Ambient temperature [°C] –5 ... +50 –5 ... +50<br>Storage temperature [°C] –20 ... +70 –20 ... +70<br>Relative humidity [%] 95, non-condensing 95, non-condensing<br>Note on vibration resistance – SG1 on H-rail<br>SG2 on direct mounting<br>Note on shock resistance – SG1 on H-rail<br>SG2 on direct mounting<br>CE marking (see declaration of conformity) [1)] – To EU Explosion Protection Directive (ATEX)<br>–<br>UKCA marking (see declaration of conformity) [1)] To UK explosion regulations<br>**----- End of picture text -----**<br> 1) Additional information: www.festo.com/catalogue/... d Support/Downloads. 2023/10 – Subject to change 101 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, digital, NAMUR ## **Connection and display components** - [1] Status LEDs (green) - 3 For allocation to inputs - 4 a Pin allocation for module [2] Channel-related error LEDs (red) [3] Error LED (red, module error) [4] Marking for intrinsically safe - ~~1 2~~ variant, CPX-P-8DE-N-IS (blue) |**Combinations of connection blocks and digital input modules**<br>Connection blocks<br>Part no.<br>CPX-P-AB-4XM12-4POL<br>**565706**|**Combinations of connection blocks and digital input modules**<br>Connection blocks<br>Part no.<br>CPX-P-AB-4XM12-4POL<br>**565706**|Digital input modules|Digital input modules| |---|---|---|---| |||CPX-P-8DE-N<br>h|CPX-P-8DE-N-IS<br>–| |CPX-P-AB-2XKL-8POL|**565704**|h|–| |CPX-P-AB-4XM12-4POL-8DE-N-IS|**565705**|–|h| |CPX-P-AB-2XKL-8POL-8DE-N-IS|**565703**|–|h| ## **Pin allocation** **==> picture [524 x 304] intentionally omitted <==** **----- Start of picture text -----**<br> Connection block outputs CPX-P-8DE-N and CPX-P-8DE-N-IS<br>CPX-P-AB-4XM12-4POL and CPX-P-AB-4XM12-4POL-8DE-N-IS<br>X1.1: BN+ [0] X3.1: BN+ [4]<br>X1.2: BU– [0] X3.2: BU– [4]<br>X1.3: BN+ [1] X3.3: BN+ [5]<br>X1.4: BU– [1] X3.4: BU– [5]<br>X2.1: BN+ [2] X4.1: BN+ [6]<br>X2.2: BU– [2] X4.2: BU– [6]<br>X2.3: BN+ [3] X4.3: BN+ [7]<br>X2.4: BU– [3] X4.4: BU– [7]<br>CPX-P-AB-2XKL-8POL and CPX-P-AB-2XKL-8POL-8DE-N-IS<br>X1.1: BN+ [0] X2.1: BN+ [4]<br>X1.2: BU– [0] X2.2: BU– [4]<br>X1.3: BN+ [1] X2.3: BN+ [5]<br>X1.4: BU– [1] X2.4: BU– [5]<br>X1.5: BN+ [2] X2.5: BN+ [6]<br>X1.6: BU– [2] X2.6: BU– [6]<br>X1.7: BN+ [3] X2.7: BN+ [7]<br>X1.8: BU– [3] X2.8: BU– [7]<br>**----- End of picture text -----**<br> Subject to change – 2023/10 102 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, digital, NAMUR **==> picture [523 x 584] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Input module, digital, to NAMUR<br>8 digital inputs 565933 CPX-P-8DE-N<br>8 digital inputs, intrinsically safe design 565934 CPX-P-8DE-N-IS<br>- Note<br>H-<br>An intrinsically safe circuit may<br>only be created using components<br>and accessories approved for<br>intrinsically safe operation.<br>Connection block<br>Plastic 4x socket, M12, 4-pin For non-intrinsically safe design 565706 CPX-P-AB-4XM12-4POL<br>For intrinsically safe design 565705 CPX-P-AB-4XM12-4POL-8DE-N-IS<br>2x plug, 8-pin For non-intrinsically safe design 565704 CPX-P-AB-2XKL-8POL<br>For intrinsically safe design 565703 CPX-P-AB-2XKL-8POL-8DE-N-IS<br>Plug<br>Push-in T-connector 1x plug M12, 4-pin 2x socket M12, 4-pin 562248 NEDU-M12D4-M12T4-IS [1)]<br>Socket, 8-pin Spring-loaded terminal Black 565712 NECU-L3G8-C1<br>Blue 565711 NECU-L3G8-C1-IS [1)]<br>Screw terminal Black 565710 NECU-L3G8-C2<br>Blue 565709 NECU-L3G8-C2-IS [1)]<br>Plug M12, 4-pin Spring-loaded terminal For cable @ 4 ... 8 mm 575719 NECU-M-S-A12G4-IS [1)]<br>Screw terminal For cable @ 2.5 ... 2.9 mm 570955 NECU-S-M12G4-P1-Q6-IS [1)]<br>For cable @ 4 ... 6 mm 570953 NECU-S-M12G4-P1-IS [1)]<br>For cable @ 6 ... 8 mm 570954 NECU-S-M12G4-P2-IS [1)]<br>For cable @ 2x3 mm or 2x5 mm 570956 NECU-S-M12G4-D-IS [1)]<br>Cover<br>Cover cap for closing off unused connections (10 pieces) For M12 165592 ISK-M12<br>connections<br>Coding element<br>To ensure that a coded socket NECU-L3G8 can only be inserted in the matching For NECU-L3G8 565713 CPX-P-KDS-AB-2XKL<br>coded connection block CPX-P-AB-2XKL (96 of each)<br>Screening plate<br>Insulating plate for safe separation of intrinsically safe and non-intrinsically safe areas of the CPX 565708 CPX-P-AB-IP<br>terminal<br>User documentation<br>User documentation German 575378 P.BE-CPX-P-EA-DE<br>English 575379 P.BE-CPX-P-EA-EN<br>Spanish 575380 P.BE-CPX-P-EA-ES<br>French 575381 P.BE-CPX-P-EA-FR<br>Italian 575382 P.BE-CPX-P-EA-IT<br>Swedish 575383 P.BE-CPX-P-EA-SV<br>**----- End of picture text -----**<br> 1) Component preferred for operation in intrinsically safe circuits. 2023/10 – Subject to change 103 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – Input module, digital ## **Area of application** ## **Function** Digital input modules enable the connection of two-wire and three-wire sensors (proximity switches, inductive or capacitive sensors, etc.). - Input modules for 24 V DC sensor supply voltage - PNP or NPN logic - Supports connection blocks with M12, M8, Sub-D and terminal connection Depending on the connection block selected, the module supports various nection connection concepts with different • Module features can be numbers of sockets (single or double parameterised allocation). - The input module receives the supply voltage for the electronics and the sensors from the interlinking block - Module protection and diagnostics through integrated electronic protection ## **General technical data** Type CPX-4DE CPX-8DE CPX-8DE-D CPX-8NDE SS Number of inputs 4 8 8 8 ~~CC~~ Max. residual current of inputs per module [A] 0.7 1 0.7 0.7 Fuse protection Internal electronic Internal electronic Internal electronic Internal electronic fuse per module fuse per module fuse per channel fuse per module ~~a~~ Intrinsic current consumption at operating voltage [mA] Typically 15 Operating voltage Nominal value [V DC] 24 ~~rs~~ Permissible range [V DC] 18 ... 30 ~~eee~~ Galvanic isolation Channel – channel No ~~rs~~ Channel – internal bus ~~eeeTT~~ No ~~eee~~ Switching level Signal 0 [V DC] š 5 › 11 Signal 1 [V DC] ~~ee~~ › 11 š 5 ~~a~~ Input debounce time [ms] 3 (0.1, 10, 20 parameterisable) ~~a~~ Input characteristic IEC 1131-T2 ~~eee~~ Switching logic Positive logic (PNP) Negative logic (NPN) LED displays Group diagnostics 1 1 1 1 Channel diagnostics – – 8 – ~~a~~ Channel status 4 8 8 8 ~~a~~ Diagnostics Short circuit/overload per channel Parameterisation • Module monitoring • Behaviour after short circuit • Input debounce time • Signal extension time ~~a~~ Degree of protection to EN 60529 Depending on connection block Temperature range Operation [°C] –5 ... +50 ~~rs~~ Storage/transport [°C] ~~eee~~ –20 ... +70 ~~eee eee~~ Materials PA-reinforced, PC ~~a~~ PWIS conformity VDMA24364-B2-L ~~a~~ Grid dimension [mm] 50 ~~TTT~~ Dimensions (including interlinking block and connection block) W x L x H [mm] 50 x 107 x 50 ~~TT TF a~~ Product weight [g] 39 39 45 40 ~~a~~ Subject to change – 2023/10 104 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, digital **==> picture [523 x 630] intentionally omitted <==** **----- Start of picture text -----**<br> Connection and display components<br>CPX-4DE CPX-8DE CPX-8DE-D CPX-8NDE<br>2 2 2 2<br>0 0 4<br>4 1 8 1 5<br>DI 2 DI 2 6<br>3 3 7<br>1 1 1 3 1<br>[1] Status LEDs (green) [2] Error LED (red, module error) [3] Channel-related error LEDs (red) For allocation to inputs<br>a Pin allocation for module<br>Combinations of connection blocks and digital input modules<br>Connection blocks Part no. Digital input modules<br>CPX-4DE CPX-8DE CPX-8DE-D CPX-8NDE<br>CPX-AB-8-M8-3POL 195706 h h h h<br>CPX-AB-4-M12X2-5POL 195704 h h h h<br>CPX-AB-4-M12X2-5POL-R 541254 h h h h<br>CPX-AB-8-KL-4POL 195708 h h h h<br>CPX-AB-1-SUB-BU-25POL 525676 h h h h<br>CPX-M-AB-4-M12X2-5POL 549367 h h h h<br>Pin allocation<br>Connection block inputs CPX-4DE CPX-8DE, CPX-8DE-D and CPX-8NDE<br>CPX-AB-8-M8-3POL<br>X1.1: 24 VSEN X5.1: 24 VSEN X1.1: 24 VSEN x X5.1: 24 VSEN x+4<br>X1.3: 0 VSEN X5.3: 0 VSEN X1.3: 0 VSEN x X5.3: 0 VSEN x+4<br>X1.4: Input x X5.4: Input x+2 X1.4: Input x X5.4: Input x+4<br>X2.1: 24 VSEN X6.1: 24 VSEN X2.1: 24 VSEN x+1 X6.1: 24 VSEN x+5<br>X2.3: 0 VSEN X6.3: 0 VSEN X2.3: 0 VSEN x+1 X6.3: 0 VSEN x+5<br>X2.4: Input x+1 X6.4: Input x+3 X2.4: Input x+1 X6.4: Input x+5<br>X3.1: 24 VSEN X7.1: 24 VSEN X3.1: 24 VSEN x+2 X7.1: 24 VSEN x+6<br>X3.3: 0 VSEN X7.3: 0 VSEN X3.3: 0 VSEN x+2 X7.3: 0 VSEN x+6<br>X3.4: Input x+1 X7.4: Input x+3 X3.4: Input x+2 X7.4: Input x+6<br>X4.1: 24 VSEN X8.1: 24 VSEN X4.1: 24 VSEN x+3 X8.1: 24 VSEN x+7<br>X4.3: 0 VSEN X8.3: 0 VSEN X4.3: 0 VSEN x+3 X8.3: 0 VSEN x+7<br>X4.4: n.c. X8.4: n.c. X4.4: Input x+3 X8.4: Input x+7<br>CPX-AB-4-M12X2-5POL, CPX-AB-4-M12X2-5POL-R [1)] and CPX-M-AB-4-M12X2-5POL<br>X1.1: 24 VSEN X3.1: 24 VSEN X1.1: 24 VSEN x X3.1: 24 VSEN x+4<br>X1.2: Input x+1 X3.2: Input x+3 X1.2: Input x+1 X3.2: Input x+5<br>X1.3: 0 VSEN X3.3: 0 VSEN X1.3: 0 VSEN x X3.3: 0 VSEN x+4<br>X1.4: Input x X3.4: Input x+2 X1.4: Input x X3.4: Input x+4<br>X1.5: FE X3.5: FE X1.5: FE X3.5: FE<br>X2.1: 24 VSEN X4.1: 24 VSEN X2.1: 24 VSEN x+2 X4.1: 24 VSEN x+6<br>X2.2: n.c. X4.2: n.c. X2.2: Input x+3 X4.2: Input x+7<br>X2.3: 0 VSEN X4.3: 0 VSEN X2.3: 0 VSENx+2 X4.3: 0 VSEN x+6<br>X2.4: Input x+1 X4.4: Input x+3 X2.4: Input x+2 X4.4: Input x+6<br>X2.5: FE X4.5: FE X2.5: FE X4.5: FE<br>**----- End of picture text -----**<br> 1) Speedcon quick lock, additional shielding on metal thread 2023/10 – Subject to change 105 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, digital ## **Pin allocation** **==> picture [524 x 405] intentionally omitted <==** **----- Start of picture text -----**<br> Connection block inputs CPX-4DE CPX-8DE, CPX-8DE-D and CPX-8NDE<br>CPX-AB-8-KL-4POL<br>X1 .0 .0 X5 X1.0: 24 VSEN X5.0: 24 VSEN X1.0: 24 VSEN x X5.0: 24 VSEN x+4<br>.1.2 .1.2 X1.1: 0 VSEN X5.1: 0 VSEN X1.1: 0 VSEN x X5.1: 0 VSEN x+4<br>.3 .3 X1.2: Input x X5.2: Input x+2 X1.2: Input x X5.2: Input x+4<br>.0 .0 X1.3: FE X5.3: FE X1.3: FE X5.3: FE<br>X2 .1 .1 X6<br>.2 .2<br>.3 .3 X2.0: 24 VSEN X6.0: 24 VSEN X2.0: 24 VSEN x+1 X6.0: 24 VSEN x+5<br>.0 .0 X2.1: 0 VSEN X6.1: 0 VSEN X2.1: 0 VSEN x+1 X6.1: 0 VSEN x+5<br>X3 .1.2 .1.2 X7 X2.2: Input x+1 X6.2: Input x+3 X2.2: Input x+1 X6.2: Input x+5<br>.3 .3 X2.3: FE X6.3: FE X2.3: FE X6.3: FE<br>.0 .0<br>.1.2 .1.2 X3.0: 24 VSEN X7.0: 24 VSEN X3.0: 24 VSEN x+2 X7.0: 24 VSEN x+6<br>X4 .3 .3 X8 X3.1: 0 VSEN X7.1: 0 VSEN X3.1: 0 VSEN x+2 X7.1: 0 VSEN x+6<br>X3.2: Input x+1 X7.2: Input x+3 X3.2: Input x+2 X7.2: Input x+6<br>X3.3: FE X7.3: FE X3.3: FE X7.3: FE<br>X4.0: 24 VSEN X8.0: 24 VSEN X4.0: 24 VSEN x+3 X8.0: 24 VSEN x+7<br>X4.1: 0 VSEN X8.1: 0 VSEN X4.1: 0 VSEN x+3 X8.1: 0 VSEN x+7<br>X4.2: n.c. X8.2: n.c. X4.2: Input x+3 X8.2: Input x+7<br>X4.3: FE X8.3: FE X4.3: FE X8.3: FE<br>CPX-AB-1-SUB-BU-25POL<br>1: Input x 14: Input x+2 1: Input x 14: Input x+4<br>2: Input x+1 15: Input x+3 2: Input x+1 15: Input x+5<br>3: Input x+1 16: Input x+3 3: Input x+2 16: Input x+6<br>4: n.c. 17: n.c. 4: Input x+3 17: Input x+7<br>5: 24 VSEN 18: 24 VSEN 5: 24 VSEN x+1 18: 24 VSEN x+4<br>6: 0 VSEN 19: 24 VSEN 6: 0 VSEN x+1 19: 24 VSEN x+5<br>7: 24 VSEN 20: 24 VSEN 7: 24 VSEN x+3 20: 24 VSEN x+6<br>8: 0 VSEN 21: 24 VSEN 8: 0 VSEN x+3 21: 24 VSEN x+7<br>9: 24 VSEN 22: 0 VSEN 9: 24 VSEN x 22: 0 VSEN x+2 u. 3<br>10: 24 VSEN 23: 0 VSEN 10: 24 VSEN x+2 23: 0 VSEN x+2 u. 3<br>11: 0 VSEN 24: 0 VSEN 11: 0 VSEN x 24: 0 VSEN x+2 u. 3<br>12: 0 VSEN 25: FE 12: 0 VSEN x+2 25: FE<br>13: FE Housing: FE 13: FE Housing: FE<br>**----- End of picture text -----**<br> Subject to change – 2023/10 106 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, digital ## **Ordering data** **==> picture [523 x 478] intentionally omitted <==** **----- Start of picture text -----**<br> Designation Part no. Type<br>Input module, digital<br>4 digital inputs, positive logic (PNP) 195752 CPX-4DE<br>8 digital inputs, positive logic (PNP) 195750 CPX-8DE<br>8 digital inputs, positive logic (PNP), enhanced diagnostic function 541480 CPX-8DE-D<br>8 digital inputs, negative logic (NPN) 543813 CPX-8NDE<br>Connection block<br>Plastic 8x socket M8, 3-pin 195706 CPX-AB-8-M8-3POL<br>4x socket M12, 5-pin 195704 CPX-AB-4-M12X2-5POL<br>4x socket, M12 with quick-lock technology, 5-pin 541254 CPX-AB-4-M12X2-5POL-R<br>Spring-loaded terminal, 32-pin 195708 CPX-AB-8-KL-4POL<br>1x Sub-D socket, 25-pin 525676 CPX-AB-1-SUB-BU-25POL<br>Metal 4x socket M12, 5-pin 549367 CPX-M-AB-4-M12X2-5POL<br>Distributor<br>1x plug M12, 4-pin 2x socket M8, 3-pin 8005311 NEDY-L2R1-V1-M8G3-N-M12G4<br>2x socket M12, 5-pin 8005310 NEDY-L2R1-V1-M12G5-N-M12G4<br>Modular system for all types of sensor/actuator distributor – NEDY-...<br>a Internet: nedy<br>Plug<br>M8, 3-pin Solderable 18696 SEA-GS-M8<br>Screw-in 192009 SEA-3GS-M8-S<br>M12, 4-pin PG7, for cable @ 4 ... 6 mm 18666 SEA-GS-7<br>PG7, for cable @ 2.5 ... 2.9 mm 192008 SEA-4GS-7-2.5<br>PG9, for cable @ 6 ... 8 mm 18778 SEA-GS-9<br>PG11, for 2x cable @ 3 ... 5 mm 18779 SEA-GS-11-DUO<br>M12, 5-pin PG7, for cable @ 4 ... 6 mm 175487 SEA-M12-5GS-PG7<br>PG11, for 2x cable @ 2.5 ... 5 mm 192010 SEA-5GS-11-DUO<br>Sub-D, 25-pin 527522 SD-SUB-D-ST25<br>Connecting cable<br>1x socket M8, 3-pin 1x plug M8, 3-pin 0.5 m 541346 NEBU-M8G3-K-0.5-M8G3<br>1.0 m 541347 NEBU-M8G3-K-1-M8G3<br>2.5 m 541348 NEBU-M8G3-K-2.5-M8G3<br>5.0 m 541349 NEBU-M8G3-K-5-M8G3<br>Modular system for a choice of connecting cables – NEBU-...<br>a Internet: nebu<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 107 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, digital **==> picture [524 x 224] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Cover<br>Cover for CPX-AB-8-KL-4POL (IP65, IP67) • 8 cable through feeds M9 538219 AK-8KL<br>• 1 cable through feed for multi-pin<br>plug<br>Fittings kit 538220 VG-K-M9<br>Screening plate<br>Screening plate for M12 connections 526184 CPX-AB-S-4-M12<br>User documentation<br>User documentation German 526439 P.BE-CPX-EA-DE<br>English 526440 P.BE-CPX-EA-EN<br>Spanish 526441 P.BE-CPX-EA-ES<br>French 526442 P.BE-CPX-EA-FR<br>Italian 526443 P.BE-CPX-EA-IT<br>**----- End of picture text -----**<br> Subject to change – 2023/10 108 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – Input module, digital, 16 inputs ## **Function** ## **Area of application** Digital input modules enable the con• Input modules for 24 V DC sensor nection of two-wire and three-wire supply voltage sensors (proximity switches, inductive • PNP logic or capacitive sensors, etc.). • Module features can be Depending on the connection block parameterised selected, the module supports various • The input module receives the supconnection concepts with different ply voltage for the electronics and numbers of sockets (single or double the sensors from the interlinking allocation). block - Module protection and diagnostics through integrated electronic protection ## **General technical data** |numbers of sockets (single or double<br>allocation).<br>the sensors from the interlinking<br>block<br>• Module protection and diagnostics<br>through integrated electronic<br>protection|numbers of sockets (single or double<br>allocation).<br>the sensors from the interlinking<br>block<br>• Module protection and diagnostics<br>through integrated electronic<br>protection|numbers of sockets (single or double<br>allocation).<br>the sensors from the interlinking<br>block<br>• Module protection and diagnostics<br>through integrated electronic<br>protection| |---|---|---| |**General technical data**<br>Type<br>CPX-16DE<br>CPX-M-16DE-D<br>Number of inputs<br>16<br>16||| |Max. residual current of inputsper module<br>[A]|1.8|1.8| |Intrinsic current consumption at operatingvoltage<br>[mA]|Typically15|Typically34| |Fuse protection|Internal electronic fuse per module|Internal electronic fuse per channel pair,<br>additional safetyfuse| |Nominal operatingvoltage<br>[V DC]|24|| |Operatingvoltage range<br>[V DC]|18 ... 30|| |Galvanic isolation<br>Channel – channel<br>Channel – internal bus|No|| ||No|| |Switching level<br>Signal 0<br>[V DC]<br>Signal 1<br>[V DC]|š5|| ||›11|| |Input debounce time<br>[ms]|3 (0.1, 10, 20parameterisable)|| |Input characteristic|IEC 1131-T2|| |Switchinglogic|Positive logic (PNP)|| |LED displays<br>Groupdiagnostics<br>Channel diagnostics<br>Channel status|1|1| ||–|16| ||16|16| |Diagnostics|Short circuit/overloadper channel|| |Parameterisation|• Module monitoring<br>• Behaviour after short circuit<br>• Input debounce time<br>• Signal extension time|| |Degree ofprotection to EN 60529|Dependingon connection block|| |Temperature range<br>Operation<br>[°C]<br>Storage/transport<br>[°C]|–5 ... +50|| ||–20 ... +70|| |Materials|PA-reinforced, PC|| |PWIS conformity|VDMA24364-B2-L|| |Grid dimension<br>[mm]|50|| |Dimensions (includinginterlinkingblock and connection block) W x L x H<br>[mm]|50 x 107 x 50|| |Product weight<br>[g]|41|46| 2023/10 – Subject to change 109 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, digital, 16 inputs ## **Connection and display components** **==> picture [524 x 142] intentionally omitted <==** **----- Start of picture text -----**<br> CPX-16DE CPX-M-16DE-D<br>[1] Status LEDs (green) [1] Common status LEDs (green)/error<br>2 2<br>For allocation to inputs LEDs (red) for each input signal<br>a Pin allocation for module [2] Error LED (red, module error)<br>[2] Error LED (red, module error)<br>1 1<br>1<br>**----- End of picture text -----**<br> ## **Combinations of connection blocks and digital input modules** **==> picture [524 x 327] intentionally omitted <==** **----- Start of picture text -----**<br> Connection blocks Part no. Digital input modules<br>CPX-16DE CPX-M-16DE-D<br>CPX-AB-8-M8X2-4POL 541256 h –<br>CPX-AB-8-KL-4POL 195708 h –<br>CPX-AB-1-SUB-BU-25POL 525676 h –<br>CPX-M-AB-8-M12X2-5POL 549335 – h<br>Pin allocation<br>Connection block inputs CPX-16DE<br>CPX-AB-8-M8x2-4POL<br>X1.1: 24 VSEN X5.1: 24 VSEN<br>X1.2: Input x+1 X5.2: Input x+9<br>X1.3: 0 VSEN X5.3: 0 VSEN<br>X1.4: Input x X5.4: Input x+8<br>X2.1: 24 VSEN X6.1: 24 VSEN<br>X2.2: Input x+3 X6.2: Input x+11<br>X2.3: 0 VSEN X6.3: 0 VSEN<br>X2.4: Input x+2 X6.4: Input x+10<br>X3.1: 24 VSEN X7.1: 24 VSEN<br>X3.2: Input x+5 X7.2: Input x+13<br>X3.3: 0 VSEN X7.3: 0 VSEN<br>X3.4: Input x+4 X7.4: Input x+12<br>X4.1: 24 VSEN X8.1: 24 VSEN<br>X4.2: Input x+7 X8.1: Input x+15<br>X4.3: 0 VSEN X8.3: 0 VSEN<br>X4.4: Input x+6 X8.4: Input x+14<br>**----- End of picture text -----**<br> Subject to change – 2023/10 110 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, digital, 16 inputs ## **Pin allocation** **==> picture [523 x 407] intentionally omitted <==** **----- Start of picture text -----**<br> Connection block inputs CPX-16DE<br>CPX-AB-8-KL-4POL<br>X1 .0 .0 X5 X1.0: Input x+8 X5.0: Input x+12<br>.1.2 .1.2 X1.1: 24 VSEN X5.1: 0 VSEN<br>.3 .3 X1.2: Input x X5.2: Input x+4<br>.0 .0 X1.3: FE X5.3: FE<br>X2 .1 .1 X6<br>.2 .2<br>.3 .3 X2.0: Input x+9 X6.0: Input x+13<br>.0 .0 X2.1: 24 VSEN X6.1: 0 VSEN<br>X3 .1.2 .1.2 X7 X2.2: Input x+1 X6.2: Input x+5<br>.3 .3 X2.3: FE X6.3: FE<br>.0 .0<br>.1.2 .1.2 X3.0: Input x+10 X7.0: Input x+14<br>X4 .3 .3 X8 X3.1: 24 VSEN X7.1: 0 VSEN<br>X3.2: Input x+2 X7.2: Input x+6<br>X3.3: FE X7.3: FE<br>X4.0: Input x+11 X8.0: Input x+15<br>X4.1: 24 VSEN X8.1: 0 VSEN<br>X4.2: Input x+3 X8.2: Input x+7<br>X4.3: FE X8.3: FE<br>CPX-AB-1-SUB-BU-25POL<br>1: Input x 14: Input x+4<br>2: Input x+1 15: Input x+5<br>3: Input x+2 16: Input x+6<br>4: Input x+3 17: Input x+7<br>5: Input x+9 18: Input x+12<br>6: 24 VSEN 19: Input x+13<br>7: Input x+11 20: Input x+14<br>8: 24 VSEN 21: Input x+15<br>9: Input x+8 22: 0 VSEN<br>10: Input x+10 23: 0 VSEN<br>11: 24 VSEN 24: 0 VSEN<br>12: 24 VSEN 25: FE<br>13: FE Housing: FE<br>**----- End of picture text -----**<br> 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 111 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, digital, 16 inputs ## **Pin allocation** **==> picture [524 x 283] intentionally omitted <==** **----- Start of picture text -----**<br> Connection block inputs CPX-M-16DE-D<br>CPX-M-AB-8-M12X2-5POL<br>X1.1: 24 VSx X5.1: 24 VSx+8<br>X1.2: Input x+1 X5.2: Input x+9<br>X1.3: 0 VSx X5.3: 0 VSx+8<br>X1.4: Input x X5.4: Input x+8<br>X1.5: FE X5.5: FE<br>X2.1: 24 VSx+2 X6.1: 24 VSx+10<br>X2.2: Input x+3 X6.2: Input x+11<br>X2.3: 0 VSx+2 X6.3: 0 VSx+10<br>X2.4: Input x+2 X6.4: Input x+10<br>X2.5: FE X6.5: FE<br>X3.1: 24 VSx+4 X7.1: 24 VSx+12<br>X3.2: Input x+5 X7.2: Input x+13<br>X3.3: 0 VSx+4 X7.3: 0 VSx+12<br>X3.4: Input x+4 X7.4: Input x+12<br>X3.5: FE X7.5: FE<br>X4.1: 24 VSx+6 X8.1: 24 VSx+14<br>X4.2: Input x+7 X8.2: Input x+15<br>X4.3: 0 VSx+6 X8.3: 0 VSx+14<br>X4.4: Input x+6 X8.4: Input x+14<br>X4.5: FE X8.5: FE<br>**----- End of picture text -----**<br> Subject to change – 2023/10 112 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, digital, 16 inputs **==> picture [523 x 484] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Input module, digital<br>16 digital inputs, internal electronic fuse per module 543815 CPX-16DE<br>16 digital inputs, internal electronic fuse per channel pair 550202 CPX-M-16DE-D<br>Connection block<br>Plastic 8x socket, M8, 4-pin 541256 CPX-AB-8-M8X2-4POL<br>Spring-loaded terminal, 32-pin 195708 CPX-AB-8-KL-4POL<br>1x Sub-D socket, 25-pin 525676 CPX-AB-1-SUB-BU-25POL<br>Metal 8x socket M12, 5-pin 549335 CPX-M-AB-8-M12X2-5POL<br>Distributor<br>1x plug M8, 4-pin 2x socket M8, 3-pin 8005312 NEDY-L2R1-V1-M8G3-N-M8G4<br>Modular system for all types of sensor/actuator distributor – NEDY-...<br>a Internet: nedy<br>Plug<br>M8, 3-pin Solderable 18696 SEA-GS-M8<br>Screw-in 192009 SEA-3GS-M8-S<br>Sub-D, 25-pin 527522 SD-SUB-D-ST25<br>Connecting cable<br>1x socket M8, 3-pin 1x plug M8, 3-pin 0.5 m 541346 NEBU-M8G3-K-0.5-M8G3<br>1.0 m 541347 NEBU-M8G3-K-1-M8G3<br>2.5 m 541348 NEBU-M8G3-K-2.5-M8G3<br>5.0 m 541349 NEBU-M8G3-K-5-M8G3<br>Modular system for a choice of connecting cables – NEBU-...<br>a Internet: nebu<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 113 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, digital, 16 inputs ## **Ordering data** **==> picture [524 x 175] intentionally omitted <==** **----- Start of picture text -----**<br> Designation Part no. Type<br>Cover<br>Cover for CPX-AB-8-KL-4POL (IP65/67) • 8 cable through feeds M9 538219 AK-8KL<br>• 1 cable through feed for multi-pin<br>plug<br>Fittings kit for cover AK-8KL 538220 VG-K-M9<br>Cover cap for closing off unused M8 connections (10 pieces) 177672 ISK-M8<br>User documentation<br>User documentation German 526439 P.BE-CPX-EA-DE<br>English 526440 P.BE-CPX-EA-EN<br>Spanish 526441 P.BE-CPX-EA-ES<br>French 526442 P.BE-CPX-EA-FR<br>Italian 526443 P.BE-CPX-EA-IT<br>**----- End of picture text -----**<br> Subject to change – 2023/10 d **Internet: www.festo.com/catalogue/...** 114 Terminal CPX-P ## Data sheet – Input module, digital, PROFIsafe ## **Function** ## **Area of application** The PROFIsafe input module has 8 in• Input module for 24 V DC sensor put channels whose signal status is supply voltage detected for safety reasons, with the • Supports connection blocks with information transmitted to a suitable M12 and terminal connection safety controller using the PROFIsafe • Module features can be safety protocol in combination with the parameterised appropriate fieldbus (PROFINET or • The input module receives the supPROFIBUS). This function is exclusively ply voltage for the electronics and available for safety controllers using the sensors from the interlinking the PROFIsafe protocol, profile version block 2.4. • Module protection and diagnostics through integrated electronic protection ## **Description** ## Module-based passivation ## Channel-based passivation While channel-based passivation is image to the safe status, even when In the case of channel-based passiva• The input information for unaffected disabled, the input module, in accordthere is only one channel error. tion, when a channel error occurs, the channel pairs does not change ance with PROFIsafe specification, input module switches the input infor• The input module remains switches all information in the input mation of the affected channel pair to integrated. 0, depending on the function mode. • The input module indicates the current channel error status to the control unit via the input image. Applications The inputs on the PROFIsafe input The function mode has an influence on There are five independent clock outThe entire input module is designed to module can be combined for the evaluation of the input signals, puts available for safe operation of ensure that the input channels provide multi-channel sensor applications. and optionally on the generation of passive sensors; the pulse patterns either secure data or no data at all, Every two inputs form a channel pair, clock signals. are used in some operating modes to even when there is a fault present in which is set separately with one of 11 detect crossovers in the signal paths. the system function modes. - The input information for unaffected channel pairs does not change ## Range of applications - Use as an input module for a high• Use of multi-channel sensor appli• Connection of various switches and er-order safety controller. Several incations with up to 8 secure inputs, sensors within the safety chain put modules can be used together which can be grouped and are suitaand these monitor mutually ble for configuration with the help of independent sensors 11 different function modes - **Note** H- The safety integrity level, Performance Level and category for the system as a whole correspond to that of the component in the safety chain with the lowest characteristic value. ## Application examples - Two-hand control device for starting • Operating mode selector switch with • Light curtain • End-position switch a function 4 positions • Acknowledge button with request • Safety door with two N/O switches - Emergency stop switch for incidents • Rotary indexing table 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 115 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, digital, PROFIsafe ## **General technical data** **==> picture [524 x 414] intentionally omitted <==** **----- Start of picture text -----**<br> Type CPX-F8DE-P<br>Number of inputs 8<br>Safety function Reliable detection and evaluation of input statuses<br>Max. address capacity Inputs [byte] 6<br>Outputs [byte] 7<br>Maximum cable length [m] 200<br>Max. power supply Per module [A] 3<br>Current consumption of module [mA] Typically 35 (power supply for electronics)<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 20.4 ... 28.8<br>Voltage drop per channel [V] 0.6<br>Residual ripple [Vss] 2 within voltage range<br>Galvanic isolation Channel – channel No<br>Input characteristics To IEC 61131-2, type 2<br>Switching logic Inputs PNP (positive switching)<br>Safety integrity level As per EN 62061 Reliable detection and evaluation of input statuses up to SIL CL3<br>As per EN 61508 Reliable detection and evaluation of input statuses up to SIL3<br>Performance Level As per ISO 13849 Reliable detection and evaluation of input statuses up to Cat 4 and PL e<br>Failure rate per hour (PFH) 1.0x 10 [-9]<br>Certificate issuing authority 01/205/5444.01/21<br>TÜV Rh. UK 01/205U/5444.00/22<br>LED displays Group diagnostics 1<br>Channel diagnostics 8<br>Channel status 8<br>Failsafe protocol active 1<br>Diagnostics • Short circuit per channel<br>• Undervoltage<br>• Overvoltage<br>• Excessive temperature<br>• Crossover per channel<br>• Wire break per channel<br>• Communication<br>• Process data error<br>• Self-test<br>Control elements DIL switch<br>Degree of protection to EN 60529 Depending on connection block<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block and connection block) W x L x H [mm] 50 x 107 x 55<br>Product weight [g] 46<br>**----- End of picture text -----**<br> Subject to change – 2023/10 116 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, digital, PROFIsafe **==> picture [523 x 159] intentionally omitted <==** **----- Start of picture text -----**<br> Materials<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Operating and environmental conditions<br>Ambient temperature [°C] –5 ... +50<br>Storage temperature [°C] –20 ... +70<br>CE marking (see declaration of conformity) [1)] To EU Machinery Directive<br>To EU EMC Directive<br>To EU RoHS Directive<br>UKCA marking (see declaration of conformity) [1)] To UK instructions for machines<br>To UK instructions for EMC<br>To UK RoHS instructions<br>Certification c UL us - Recognized (OL)<br>**----- End of picture text -----**<br> - 1) More information: www.festo.com/catalogue/... d Support/Downloads. **Connection and display components** CPX-F8DE-P [1] Channel-related status LEDs [3] Fail-safe protocol active (green) 4 (green): [4] Error LED (red, module error) [2] Channel-related error LEDs (red) ~~1 2 3~~ ## **Combinations of bus nodes/control blocks with PROFIsafe input module** |~~1~~<br>~~2~~<br>~~3~~|~~1~~<br>~~2~~<br>~~3~~|~~1~~<br>~~2~~<br>~~3~~| |---|---|---| |**Combinations of bus nodes/control blocks with PROFIsafe input module**||| |Bus node/control block<br>CPX-FB13|Part no.<br>**195740**|PROFIsafe input module| |||CPX-F8DE-P<br>h| |CPX-FB43|**8110369**|h| |CPX-M-FB44|**8110370**|h| |CPX-M-FB45|**8110371**|h| ## - **Note** H- The PROFIsafe input module CPX-F8DE-P can only be connected as of software release 21 or release 30 (in the case of CPX-FB13). 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 117 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, digital, PROFIsafe **==> picture [524 x 484] intentionally omitted <==** **----- Start of picture text -----**<br> Combinations of connection blocks and PROFIsafe input module<br>Connection blocks Part no. PROFIsafe input module<br>CPX-F8DE-P<br>CPX-M-AB-4-M12X2-5POL 549367 h<br>CPX-AB-8-KL-4POL 195708 h<br>Pin allocation<br>Connection block inputs CPX-F8DE-P<br>CPX-M-AB-4-M12X2-5POL<br>X1.1: 24 VSEN X3.1: 24 VSEN<br>X1.2: Input x+1 X3.2: Input x+5<br>X1.3: 0 VSEN X3.3: 0 VSEN<br>X1.4: Input x X3.4: Input x+4<br>X1.5: FE X3.5: FE<br>X2.1: 24 VSEN X4.1: 24 VSEN<br>X2.2: Input x+3 X4.2: Input x+7<br>X2.3: 0 VSEN X4.3: 0 VSEN<br>X2.4: Input x+2 X4.4: Input x+6<br>X2.5: FE X4.5: FE<br>CPX-AB-8-KL-4POL<br>X1 .0 .0 X5 X1.0: 24 VSEN X5.0: 24 VSEN<br>.1.2 .1.2 X1.1: 0 VSEN X5.1: 0 VSEN<br>.3 .3 X1.2: Input x X5.2: Input x+4<br>.0 .0 X1.3: FE X5.3: FE<br>X2 .1 .1 X6<br>.2 .2<br>.3 .3 X2.0: 24 VSEN x X6.0: 24 VSEN x+4<br>.0 .0 X2.1: 24 VSEN x+1 X6.1: 24 VSEN x+5<br>X3 .1.2 .1.2 X7 X2.2: Input x+1 X6.2: Input x+5<br>.3 .3 X2.3: FE X6.3: FE<br>.0 .0<br>.1.2 .1.2 X3.0: 24 VSEN X7.0: 24 VSEN<br>X4 .3 .3 X8 X3.1: 0 VSEN X7.1: 0 VSEN<br>X3.2: Input x+2 X7.2: Input x+6<br>X3.3: FE X7.3: FE<br>X4.0: 24 VSEN x+2 X8.0: 24 VSEN x+6<br>X4.1: 24 VSEN x+3 X8.1: 24 VSEN x+7<br>X4.2: Input x+3 X8.2: Input x+7<br>X4.3: FE X8.3: FE<br>**----- End of picture text -----**<br> Subject to change – 2023/10 118 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, digital, PROFIsafe ## **Combinations of interlinking blocks and PROFIsafe input module** |Data sheet – Input module, digital, PROFIsafe|Data sheet – Input module, digital, PROFIsafe|Data sheet – Input module, digital, PROFIsafe| |---|---|---| |**Combinations of interlinking blocks and PROFIsafe input module**||| |Interlinking blocks<br>CPX-M-GE-EV-S-7/8-5POL|Part no.<br>**550208**|PROFIsafe input module| |||CPX-F8DE-P<br>h| |CPX-M-GE-EV-S-7/8-5POL-VL|**8022165**|h| |CPX-M-GE-EV|**550206**|h| |CPX-M-GE-EV-FVO|**567806**|–| |CPX-M-GE-EV-Z-7/8-5POL|**550210**|h| |CPX-M-GE-EV-Z-7/8-5POL-VL|**8022158**|h| ## **Ordering data** **==> picture [523 x 462] intentionally omitted <==** **----- Start of picture text -----**<br> Description Part no. Type<br>PROFIsafe input module<br>8 digital inputs, positive logic (PNP), for reliable detection and evaluation of input statuses 2597424 CPX-F8DE-P<br>Connection block<br>Plastic Spring-loaded terminal, 32-pin 195708 CPX-AB-8-KL-4POL<br>Metal 4x socket M12, 5-pin Unpulsed sensor supply 549367 CPX-M-AB-4-M12X2-5POL<br>Distributor<br>1x plug M12, 4-pin 2x socket M12, 5-pin 8005310 NEDY-L2R1-V1-M12G5-N-M12G4<br>Modular system for all types of sensor/actuator distributor – NEDY-...<br>a Internet: nedy<br>Plug<br>M12, 4-pin PG7, for cable @ 4 ... 6 mm 18666 SEA-GS-7<br>PG7, for cable @ 2.5 ... 2.9 mm 192008 SEA-4GS-7-2.5<br>PG9, for cable @ 6 ... 8 mm 18778 SEA-GS-9<br>PG11, for 2x cable @ 3 ... 5 mm 18779 SEA-GS-11-DUO<br>M12, 5-pin PG7, for cable @ 4 ... 6 mm 175487 SEA-M12-5GS-PG7<br>PG11, for 2x cable @ 2.5 ... 5 mm 192010 SEA-5GS-11-DUO<br>Connecting cable<br>Modular system for a choice of connecting cables – NEBU-...<br>a Internet: nebu<br>User documentation<br>User documentation for PROFIsafe input module German 8035496 CPX-F8DE-P-DE<br>English 8035497 CPX-F8DE-P-EN<br>Spanish 8035498 CPX-F8DE-P-ES<br>French 8035499 CPX-F8DE-P-FR<br>Italian 8035500 CPX-F8DE-P-IT<br>Chinese 8035501 CPX-F8DE-P-ZH<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 119 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – Output module, digital ## **Function** ## **Area of application** - Digital outputs control actuators such • Output module for 24 V DC supply as individual valves, hydraulic valves, voltage heating controllers and many more. • PNP logic Separate circuits are created using an • Module features can be additional supply. Parallel connection parameterised of the outputs of a module enables • The output module receives the voltconsuming devices to be controlled age supply for the electronics and with up to 4 A. the outputs from the interlinking block - Module protection and diagnostics through integrated electronic protection in each channel ## **General technical data** Type CPX-4DA CPX-8DA CPX-8DA-H a Number of outputs 4 8 8 Max. power supply Per module [A] 4 8.4 Per channel [A] 1 (24 W lamp load, 0.5 (12 W lamp load, 2.1 (50 W lamp load), per 4 channels can be 8 channels can be channel pair ~~es~~ connected in ~~ee~~ parallel) connected in parallel) Fuse protection (short circuit) Internal electronic fuse per channel ~~Ce~~ Module current consumption (power supply for electronics) [mA] Typically 16 Typically 34 Operating voltage Nominal value [V DC] 24 ~~ei~~ Permissible range [V DC] 18 ... 30 Galvanic isolation Channel – channel No ~~OO~~ Channel – internal bus Yes, with intermediate supply ~~GO~~ Output characteristic Based on IEC 1131-2 ~~I~~ Switching logic Positive logic (PNP) LED displays Group diagnostics 1 1 1 Channel diagnostics 4 8 8 ~~a~~ Channel status 4 8 8 Diagnostics • Short circuit/overload, channel x ~~Se~~ • Undervoltage of outputs Parameterisation • Module monitoring • Behaviour after short circuit • Fail-safe channel x • Forcing channel x • Idle mode channel x ~~GO~~ Degree of protection to EN 60529 Depending on connection block Temperature range Operation [°C] –5 ... +50 ~~oo~~ Storage/transport [°C] –20 ... +70 ~~GO~~ Materials PA-reinforced, PC ~~GO~~ PWIS conformity VDMA24364-B2-L ~~GO~~ Grid dimension [mm] 50 Dimensions (including interlinking block and connection block) W x L x H [mm] 50 x 107 x 50 ~~ee~~ Product weight [g] 42 49 48 Subject to change – 2023/10 120 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Output module, digital **==> picture [523 x 240] intentionally omitted <==** **----- Start of picture text -----**<br> Connection and display components<br>CPX-4DA CPX-8DA<br>[1] Status LEDs (yellow)<br>3 3<br>For allocation to outputs<br>a Pin allocation for module<br>[2] Channel-related error LEDs (red)<br>[3] Error LED (red, module error)<br>1 2 1 2<br>Combinations of connection block and digital output module<br>Connection blocks Part no. Digital output module<br>CPX-4DA CPX-8DA CPX-8DA-H<br>CPX-AB-8-M8-3POL 195706 h h –<br>CPX-AB-8-M8X2-4POL 541256 h h h<br>CPX-AB-4-M12X2-5POL 195704 h h –<br>CPX-AB-4-M12X2-5POL-R 541254 h h h<br>CPX-AB-8-KL-4POL 195708 h h h<br>CPX-AB-1-SUB-BU-25POL 525676 h h h<br>CPX-M-AB-4-M12X2-5POL 549367 h h h<br>**----- End of picture text -----**<br> **==> picture [523 x 198] intentionally omitted <==** **----- Start of picture text -----**<br> Pin allocation<br>Connection block outputs CPX-4DA CPX-8DA<br>CPX-AB-8-M8-3POL<br>X1.1: n.c. X5.1: n.c. X1.1: n.c. X5.1: n.c.<br>X1.3: 0 VOUT X5.3: 0 VOUT X1.3: 0 VOUT X5.3: 0 VOUT<br>X1.4: Output x X5.4: Output x+2 X1.4: Output x X5.4: Output x+4<br>X2.1: n.c. X6.1: n.c. X2.1: n.c. X6.1: n.c.<br>X2.3: 0 VOUT X6.3: 0 VOUT X2.3: 0 VOUT X6.3: 0 VOUT<br>X2.4: Output x+1 X6.4: Output x+3 X2.4: Output x+1 X6.4: Output x+5<br>X3.1: n.c. X7.1: n.c. X3.1: n.c. X7.1: n.c.<br>X3.3: 0 VOUT X7.3: 0 VOUT X3.3: 0 VOUT X7.3: 0 VOUT<br>X3.4: Output x+1 X7.4: Output x+3 X3.4: Output x+2 X7.4: Output x+6<br>X4.1: n.c. X8.1: n.c. X4.1: n.c. X8.1: n.c.<br>X4.3: 0 VOUT X8.3: 0 VOUT X4.3: 0 VOUT X8.3: 0 VOUT<br>X4.4: n.c. X8.4: n.c. X4.4: Output x+3 X8.4: Output x+7<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 121 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Output module, digital ## **Pin allocation** **==> picture [524 x 626] intentionally omitted <==** **----- Start of picture text -----**<br> Connection block outputs CPX-4DA CPX-8DA and CPX-8DA-H<br>CPX-AB-8-M8X2-4POL<br>X1.1: 0 VOUT X5.1: 0 VOUT X1.1: 0 VOUT X5.1: 0 VOUT<br>X1.2: Output x+1 X5.2: n.c. X1.2: Output x+1 X5.2: n.c.<br>X1.3: 0 VOUT X5.3: 0 VOUT X1.3: 0 VOUT X5.3: 0 VOUT<br>X1.4: Output x X5.4: n.c. X1.4: Output x X5.4: n.c.<br>X2.1: 0 VOUT X6.1: 0 VOUT X2.1: 0 VOUT X6.1: 0 VOUT<br>X2.2: n.c. X6.2: n.c. X2.2: Output x+3 X6.2: n.c.<br>X2.3: 0 VOUT X6.3: 0 VOUT X2.3: 0 VOUT X6.3: 0 VOUT<br>X2.4: Output x+1 X6.4: n.c. X2.4: Output x+2 X6.4: n.c.<br>X3.1: 0 VOUT X7.1: 0 VOUT X3.1: 0 VOUT X7.1: 0 VOUT<br>X3.2: Output x+3 X7.2: n.c. X3.2: Output x+5 X7.2: n.c.<br>X3.3: 0 VOUT X7.3: 0 VOUT X3.3: 0 VOUT X7.3: 0 VOUT<br>X3.4: Output x+2 X7.4: n.c. X3.4: Output x+4 X7.4: n.c.<br>X4.1: 0 VOUT X8.1: 0 VOUT x+1 X4.1: 0 VOUT X8.1: 0 VOUT<br>X4.2: n.c. X8.2: n.c. X4.2: Output x+7 X8.2: n.c.<br>X4.3: 0 VOUT X8.3: 0 VOUT x+3 X4.3: 0 VOUT X8.3: 0 VOUT<br>X4.4: Output x+3 X8.4: n.c. X4.4: Output x+6 X8.4: n.c.<br>CPX-AB-4-M12X2-5POL [1)] and CPX-AB-4-M12X2-5POL-R [2)] and CPX-M-AB-4-M12X2-5POL<br>X1.1: n.c. X3.1: n.c. X1.1: n.c. X3.1: n.c.<br>X1.2: Output x+1 X3.2: Output x+3 X1.2: Output x+1 X3.2: Output x+5<br>X1.3: 0 VOUT X3.3: 0 VOUT X1.3: 0 VOUT X3.3: 0 VOUT<br>X1.4: Output x X3.4: Output x+2 X1.4: Output x X3.4: Output x+4<br>X1.5: FE X3.5: FE X1.5: FE X3.5: FE<br>X2.1: n.c. X4.1: n.c. X2.1: n.c. X4.1: n.c.<br>X2.2: n.c. X4.2: n.c. X2.2: Output x+3 X4.2: Output x+7<br>X2.3: 0 VOUT X4.3: 0 VOUT X2.3: 0 VOUT X4.3: 0 VOUT<br>X2.4: Output x+1 X4.4: Output x+3 X2.4: Output x+2 X4.4: Output x+6<br>X2.5: FE X4.5: FE X2.5: FE X4.5: FE<br>CPX-AB-8-KL-4POL<br>X1 .0 .0 X5 X1.0: n.c. X5.0: n.c. X1.0: n.c. X5.0: n.c.<br>.1.2 .1.2 X1.1: 0 VOUT X5.1: 0 VOUT X1.1: 0 VOUT X5.1: 0 VOUT<br>.3 .3 X1.2: Output x X5.2: Output x+2 X1.2: Output x X5.2: Output x+4<br>.0 .0 X1.3: FE X5.3: FE X1.3: FE X5.3: FE<br>X2 .1 .1 X6<br>.2 .2<br>X2.0: n.c. X6.0: n.c. X2.0: n.c. X6.0: n.c.<br>.3 .3<br>.0 .0 X2.1: 0 VOUT X6.1: 0 VOUT X2.1: 0 VOUT X6.1: 0 VOUT<br>X3 .1.2 .1.2 X7 X2.2: Output x+1 X6.2: Output x+3 X2.2: Output x+1 X6.2: Output x+5<br>.3 .3 X2.3: FE X6.3: FE X2.3: FE X6.3: FE<br>.0 .0<br>.1 .1 X3.0: n.c. X7.0: n.c. X3.0: n.c. X7.0: n.c.<br>.2 .2<br>X4 .3 .3 X8 X3.1: 0 VOUT X7.1: 0 VOUT X3.1: 0 VOUT X7.1: 0 VOUT<br>X3.2: Output x+1 X7.2: Output x+3 X3.2: Output x+2 X7.2: Output x+6<br>X3.3: FE X7.3: FE X3.3: FE X7.3: FE<br>X4.0: n.c. X8.0: n.c. X4.0: n.c. X8.0: n.c.<br>X4.1: 0 VOUT X8.1: 0 VOUT X4.1: 0 VOUT X8.1: 0 VOUT<br>X4.2: n.c. X8.2: n.c. X4.2: Output x+3 X8.2: Output x+7<br>X4.3: FE X8.3: FE X4.3: FE X8.3: FE<br>**----- End of picture text -----**<br> - 1) Not suitable for CPX-8DA-H. - 2) Speedcon quick lock, additional shielding on metal thread Subject to change – 2023/10 122 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Output module, digital ## **Pin allocation** **==> picture [523 x 184] intentionally omitted <==** **----- Start of picture text -----**<br> Connection block outputs CPX-4DA CPX-8DA and CPX-8DA-H<br>CPX-AB-1-SUB-BU-25POL<br>1: Output x 14: Output x+2 1: Output x 14: Output x+4<br>2: Output x+1 15: Output x+3 2: Output x+1 15: Output x+5<br>3: Output x+1 16: Output x+3 3: Output x+2 16: Output x+6<br>4: n.c. 17: n.c. 4: Output x+3 17: Output x+7<br>5: n.c. 18: n.c. 5: n.c. 18: n.c.<br>6: 0 VOUT 19: n.c. 6: 0 VOUT 19: n.c.<br>7: n.c. 20: n.c. 7: n.c. 20: n.c.<br>8: 0 VOUT 21: n.c. 8: 0 VOUT 21: n.c.<br>9: n.c. 22: 0 VOUT 9: n.c. 22: 0 VOUT<br>10: n.c. 23: 0 VOUT 10: n.c. 23: 0 VOUT<br>11: 0 VOUT 24: 0 VOUT 11: 0 VOUT 24: 0 VOUT<br>12: 0 VOUT 25: FE 12: 0 VOUT 25: FE<br>13: FE Housing: FE 13: FE Housing: FE<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 123 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Output module, digital ## **Ordering data** **==> picture [524 x 531] intentionally omitted <==** **----- Start of picture text -----**<br> Designation Part no. Type<br>Output module, digital<br>4 digital outputs, power supply 1 A per channel 195754 CPX-4DA<br>8 digital outputs, power supply 0.5 A per channel 541482 CPX-8DA<br>8 digital outputs, power supply 2.1 A per channel pair 550204 CPX-8DA-H<br>Connection block<br>Plastic 8x socket, M8, 3-pin 195706 CPX-AB-8-M8-3POL<br>8x socket, M8, 4-pin 541256 CPX-AB-8-M8X2-4POL<br>4x socket, M12, 5-pin 195704 CPX-AB-4-M12X2-5POL<br>4x socket, M12, 5-pin with quick-lock technology 541254 CPX-AB-4-M12X2-5POL-R<br>Spring-loaded terminal, 32-pin 195708 CPX-AB-8-KL-4POL<br>1x Sub-D socket, 25-pin 525676 CPX-AB-1-SUB-BU-25POL<br>Metal 4x socket, M12, 5-pin 549367 CPX-M-AB-4-M12X2-5POL<br>Distributor<br>1x plug M8, 4-pin 2x socket M8, 3-pin 8005312 NEDY-L2R1-V1-M8G3-N-M8G4<br>1x plug M12, 4-pin 2x socket M8, 3-pin 8005311 NEDY-L2R1-V1-M8G3-N-M12G4<br>2x socket M12, 5-pin 8005310 NEDY-L2R1-V1-M12G5-N-M12G4<br>Modular system for all types of sensor/actuator distributor – NEDY-...<br>a Internet: nedy<br>Plug<br>M8, 3-pin Solderable 18696 SEA-GS-M8<br>Screw-in 192009 SEA-3GS-M8-S<br>Insulation displacement 0.1 ... 0.14 mm [2] 564945 NECU-S-M8G3-HX-Q3<br>connector 0.14 ... 0.34 mm [2] 562024 NECU-S-M8G3-HX<br>M12, 4-pin PG7, for cable @ 4 ... 6 mm 18666 SEA-GS-7<br>PG7, for cable @ 2.5 ... 2.9 mm 192008 SEA-4GS-7-2.5<br>PG9, for cable @ 6 ... 8 mm 18778 SEA-GS-9<br>PG11, for 2x cable @ 3 ... 5 mm 18779 SEA-GS-11-DUO<br>M12, 5-pin PG7, for cable @ 4 ... 6 mm 175487 SEA-M12-5GS-PG7<br>PG11, for 2x cable @ 2.5 ... 5 mm 192010 SEA-5GS-11-DUO<br>Sub-D, 25-pin 527522 SD-SUB-D-ST25<br>Connecting cable<br>1x socket M8, 3-pin 1x plug M8, 3-pin 0.5 m 541346 NEBU-M8G3-K-0.5-M8G3<br>1.0 m 541347 NEBU-M8G3-K-1-M8G3<br>2.5 m 541348 NEBU-M8G3-K-2.5-M8G3<br>5.0 m 541349 NEBU-M8G3-K-5-M8G3<br>Modular system for a choice of connecting cables – NEBU-...<br>a Internet: nebu<br>**----- End of picture text -----**<br> Subject to change – 2023/10 124 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Output module, digital **==> picture [523 x 247] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Cover<br>Cover for CPX-AB-8-KL-4POL (IP65/67) • 8 cable through feeds M9 538219 AK-8KL<br>• 1 cable through feed for multi-pin<br>plug<br>Fittings kit, cover for AK-8KL 538220 VG-K-M9<br>Cover cap for closing off unused connections (10 pieces) For M8 connections 177672 ISK-M8<br>For M12 connections 165592 ISK-M12<br>Screening plate<br>Screening plate for connection block 526184 CPX-AB-S-4-M12<br>• CPX-AB-4-M12X2-5POL<br>• CPX-AB-4-M12X2-5POL-R<br>User documentation<br>User documentation German 526439 P.BE-CPX-EA-DE<br>English 526440 P.BE-CPX-EA-EN<br>Spanish 526441 P.BE-CPX-EA-ES<br>French 526442 P.BE-CPX-EA-FR<br>Italian 526443 P.BE-CPX-EA-IT<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 125 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – Input/output module, digital ## **Area of application** - Digital multi I/O module for 24 V DC • The outputs receive the voltage supsupply voltage ply for the electronics and the out- - • Supports connection blocks with puts from the interlinking block Sub-D, terminal connection and • Module protection and diagnostics M12 connection (8-pin) through integrated electronic fuse - Sub-D, terminal connection and • Module protection and diagnostics M12 connection (8-pin) through integrated electronic fuse - • Module features can be protection for the sensor power supparameterised ply and integrated electronic fuse - • The inputs receive the voltage protection in each output channel supply for the electronics and the sensors from the interlinking block ## **General technical data** |• Module features can be<br>parameterised<br>• The inputs receive the voltage<br>supply for the electronics and the<br>sensors from the interlinking block<br>protection for the sensor power sup-<br>ply and integrated electronic fuse<br>protection in each output channel|• Module features can be<br>parameterised<br>• The inputs receive the voltage<br>supply for the electronics and the<br>sensors from the interlinking block<br>protection for the sensor power sup-<br>ply and integrated electronic fuse<br>protection in each output channel| |---|---| |**General technical data**<br>Type<br>CPX-8DE-8DA<br>Number<br>Inputs<br>8<br>Outputs<br>8<br>~~————————~~<br>~~CO~~|| ||8<br>~~———————~~<br>~~CO~~| |Max. power supply<br>Per module<br>Sensor supply<br>[A]<br>Outputs<br>[A]<br>~~————————~~<br>~~CO~~<br>~~en~~|0.7<br>~~———————~~<br>~~CO~~| ||4| |Max.power supply per channel<br>[A]<br>~~a~~<br>~~CC~~|0.5 (12 W lampload, channels A0 ... A03 can be connected inparallel to A4 ... A7)<br>~~a~~<br>| |Fuseprotection (short circuit)<br>~~CC~~|Internal electronic fuseper channel<br>| |Intrinsic current consumption at nominal operatingvoltage<br>[mA]<br>~~CCRO~~<br>~~a~~|Typically22<br>~~RO~~<br>~~TTNYTNTNHTHTT._1"~~| |Operating voltage<br>Nominal value<br>[V DC]<br>Permissible range<br>[V DC]<br>~~a~~<br>~~**C**~~<br>~~RC~~|24<br>~~TTNYTNTNHTHTT._1"~~<br>~~**C**O~~| ||18 ... 30<br>~~TTNYTNTNHTHTT._1"~~<br>~~**C**O~~| |Galvanic isolation, inputs<br>Channel – channel<br>Channel – internal bus<br>~~a~~<br>~~**C**~~<br>~~RC~~<br>~~—~~<br>~~TTOoyoH,"_~~|No<br>~~TTNYTNTNHTHTT._1"~~<br>~~**C**O~~<br>~~TTOoyoH,"_~~<br>~~O~~| ||No<br>~~**C**O~~<br>~~TTOoyoH,"_~~<br>~~O~~| |Galvanic isolation, outputs<br>Channel – channel<br>Channel – internal bus<br>~~**C**~~<br>~~RC~~<br>~~—~~<br>~~TTOoyoH,"_~~<br>~~————~~<br>~~SS~~<br>~~J,-ITOTYT—~~|No<br>~~**C**O~~<br>~~TTOoyoH,"_~~<br>~~O~~<br>~~————~~| ||Yes, with intermediate supply<br>~~————~~<br>~~J,-ITOTYT—~~| |Characteristic curve<br>Inputs<br>Outputs<br>~~SS~~<br>~~J,-ITOTYT—~~|IEC 1131-T2<br>~~J,-ITOTYT—~~| ||IEC 1131-T2<br>~~J,-ITOTYT—~~| |Switching level, inputs<br>Signal 0<br>[V DC]<br>Signal 1<br>[V DC]<br>~~SS~~<br>~~J,-ITOTYT—~~|š5<br>~~J,-ITOTYT—~~| ||›11| |Input debounce time<br>[ms]<br>~~|~~<br>~~CO~~|3 (0.1 ms, 10 ms, 20 msparameterisable)<br>~~|~~<br>| |Switchinglogic<br>~~CO~~|Positive logic (PNP)<br>| |LED displays<br>Groupdiagnostics<br>Channel status<br>~~COJ~~|1<br>~~CT~~| ||16<br>~~CT~~| |Diagnostics|• Short circuit/overload per channel<br>• Undervoltage of outputs| |Parameterisation|• Input debounce time<br>• Failsafe per channel<br>• Forcing per channel<br>• Idle mode per channel<br>• Signal extension time<br>• Module monitoring<br>• Behaviour after short circuit| |Degree ofprotection to EN 60529<br>~~|~~|Dependingon connection block<br>~~|~~| |Temperature range<br>Operation<br>[°C]<br>Storage/transport<br>[°C]<br>~~OO~~|–5 ... +50<br>~~OO~~| ||–20 ... +70<br>~~OO~~<br>~~CT~~| |Materials<br>~~OO~~|PA-reinforced, PC<br>~~OO~~| |PWIS conformity<br>~~GO~~|VDMA24364-B2-L<br>~~GO~~| |Grid dimension<br>[mm]<br>~~CO~~|50<br>~~CO~~| |Dimensions (including interlinking block and connection block)<br>W x L x H<br>[mm]|50 x 107 x 50| |Product weight<br>[g]<br>~~ee~~|48<br>~~ee~~| Subject to change – 2023/10 126 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input/output module, digital ## **Connection and display components** CPX-8DE-8DA ||||**0**|**0**|**0**|**4**|**4**|||**0**||**4**||||||3|[1]|Status LEDs (green)<br>For allocation to inputs|[3] Error LED (red, module error)| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| ||**8**||**1**|||**5**||||**1**||**5**|||**8**|||||aPin allocation for module|| ||**DI**||**2**<br>**3**|||**6**<br>**7**||||**2**<br>**3**||**6**<br>**7**|||**DO**||||[2]|Status LEDs (yellow)<br>For allocation to outputs|| |||||||||||||||||||||aPin allocation for module|| |||||||~~1~~||||||~~2~~|||||||||| **==> picture [523 x 316] intentionally omitted <==** **----- Start of picture text -----**<br> Connection block/digital I/O module combinations<br>Connection blocks Part no. Digital I/O module<br>CPX-8DE-8DA<br>CPX-AB-4-M12-8POL 526178 h<br>CPX-AB-8-KL-4POL 195708 h<br>CPX-AB-1-SUB-BU-25POL 525676 h<br>Pin allocation<br>Connection block inputs/outputs CPX-8DE-8DA<br>CPX-AB-4-M12-8POL<br>X1.1: 24 VSEN X3.1: 24 VSEN<br>X1.2: Input x X3.2: Input x+4<br>X1.3: Input x+1 X3.3: Input x+5<br>X1.4: 0 VSEN X3.4: 0 VSEN<br>X1.5: Output x X3.5: Output x+4<br>X1.6: Output x+1 X3.6: Output x+5<br>X1.7: Input x+4 X3.7: n.c.<br>X1.8: 0 VOUT X3.8: 0 VOUT<br>X2.1: 24 VSEN X4.1: 24 VSEN<br>X2.2: Input x+2 X4.2: Input x+6<br>X2.3: Input x+3 X4.3: Input x+7<br>X2.4: 0 VSEN X4.4: 0 VSEN<br>X2.5: Output x+2 X4.5: Output x+6<br>X2.6: Output x+3 X4.6: Output x+7<br>X2.7: Input x+6 X4.7: n.c.<br>X2.8: 0 VOUT X4.8: 0 VOUT<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 127 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input/output module, digital ## **Pin allocation** **==> picture [524 x 405] intentionally omitted <==** **----- Start of picture text -----**<br> Connection block inputs/outputs CPX-8DE-8DA<br>CPX-AB-8-KL-4POL<br>X1 .0 .0 X5 X1.0: 24 VSEN X5.0: Output x+4<br>.1.2 .1.2 X1.1: 0 VSEN X5.1: 0 VOUT<br>.3 .3 X1.2: Input x X5.2: Output x<br>.0 .0 X1.3: FE X5.3: FE<br>X2 .1 .1 X6<br>.2 .2<br>.3 .3 X2.0: Input x+4 X6.0: Output x+5<br>.0 .0 X2.1: Input x+5 X6.1: 0 VOUT<br>X3 .1.2 .1.2 X7 X2.2: Input x+1 X6.2: Output x+1<br>.3 .3 X2.3: FE X6.3: FE<br>.0 .0<br>.1.2 .1.2 X3.0: 24 VSEN X7.0: Output x+6<br>X4 .3 .3 X8 X3.1: 0 VSEN X7.1: 0 VOUT<br>X3.2: Input x+2 X7.2: Output x+2<br>X3.3: FE X7.3: FE<br>X4.0: Input x+6 X8.0: Output x+7<br>X4.1: Input x+7 X8.1: 0 VOUT<br>X4.2: Input x+3 X8.2: Output x+3<br>X4.3: FE X8.3: FE<br>CPX-AB-1-SUB-BU-25POL<br>1: Input x 14: Output x<br>2: Input x+1 15: Output x+1<br>3: Input x+2 16: Output x+2<br>4: Input x+3 17: Output x+3<br>5: Input x+4 18: Output x+4<br>6: Input x+5 19: Output x+5<br>7: Input x+6 20: Output x+6<br>8: Input x+7 21: Output x+7<br>9: 24 VSEN 22: 0 VOUT<br>10: 24 VSEN 23: 0 VOUT<br>11: 0 VSEN 24: 0 VOUT<br>12: 0 VSEN 25: FE<br>13: FE Housing: FE<br>**----- End of picture text -----**<br> Subject to change – 2023/10 128 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input/output module, digital **==> picture [523 x 477] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Input/output module, digital<br>8 digital inputs, 8 digital outputs 526257 CPX-8DE-8DA<br>Connection block<br>Plastic 4x socket M12, 8-pin 526178 CPX-AB-4-M12-8POL<br>Spring-loaded terminal, 32-pin 195708 CPX-AB-8-KL-4POL<br>1x socket, Sub-D, 25-pin 525676 CPX-AB-1-SUB-BU-25POL<br>Plug<br>Sub-D, 25-pin 527522 SD-SUB-D-ST25<br>Connecting cable<br>Connecting cable M12 525617 KM12-8GD8GS-2-PU<br>Cover<br>Cover for CPX-AB-8-KL-4POL (IP65, IP67) • 8 cable through feeds M9 538219 AK-8KL<br>• 1 cable through feed for multi-pin<br>plug<br>Fittings kit 538220 VG-K-M9<br>Screening plate<br>Screening plate for M12 connections 526184 CPX-AB-S-4-M12<br>User documentation<br>User documentation German 526439 P.BE-CPX-EA-DE<br>English 526440 P.BE-CPX-EA-EN<br>Spanish 526441 P.BE-CPX-EA-ES<br>French 526442 P.BE-CPX-EA-FR<br>Italian 526443 P.BE-CPX-EA-IT<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 129 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – Counter module, digital ## **Function** The counter module has two channels. Depending on the parameterisation, these can independently be used as counter inputs or as incremental value encoder inputs or SSI. The counter module additionally has one output per channel. The outputs can either be controlled by a counter channel or an incremental value encoder channel, i.e. through an event such as "Comparative value reached". Alternatively, outputs can also be controlled via process data. ## **Area of application** - Continuous counting - One-off counting to count limit - One-off counting to count limit, return to load value - Periodic counting - Measurement of frequencies - Measurement of rotational speeds - Measurement of duty cycle - Measurement of position - Measurement of speed - Measuring with pulse generators - Measurement with pulse generators and direction encoders - Measurement with incremental encoders - Measurement with SSI absolute encoders ## **Description** Applications - Recording travel and speed of a conveyor - Position and speed synchronisation of conveyors and pick & place applications - Counting goods e.g. in packaging installations - Systems for filling by weight and volume - Monitoring motor speeds - Measuring equipment for determining the position of axis systems (linear, rotational) - Controlling fast-switching valves - Controlling the opening time of a valve - Activating semiconductor relays - Temperature monitoring and rotational speed control for drives - Change of direction in fast drives - Control of motors with pulse-width modulation (PWM) ## Supported devices - 5 V incremental encoder, • 24 V incremental encoder, single-ended or differential, with single-ended, with two 90° phase two 90° phase offset tracks offset tracks - 24 V pulse generator with or without • Absolute encoder with SSI interface direction level (13 bits to 25 bits) - 24 V direct current motors Subject to change – 2023/10 130 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Counter module, digital ## **General technical data** **==> picture [523 x 579] intentionally omitted <==** **----- Start of picture text -----**<br> Type CPX-2ZE2DA<br>Number Inputs 2<br>Outputs 2<br>Max. power supply Inputs [A] 2<br>Per module Outputs [A] 10<br>Max. power supply per channel [A] 5 (adjustable, 20 W lamp load)<br>Max. cable length [m] 30<br>Fuse protection (short circuit) Internal electronic fuse per channel<br>Intrinsic current consumption at nominal operating voltage [mA] Typically 35<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 18 ... 30<br>Galvanic isolation, inputs Channel – channel No<br>Channel – internal bus No<br>Galvanic isolation, outputs Channel – channel No<br>Channel – internal bus Yes, if an intermediate supply is used<br>Characteristic curve Inputs To IEC 1131-2, type 2<br>Outputs IEC 1131-T2<br>Switching level Signal 0 [V DC] š 5<br>Signal 1 [V DC] › 11<br>Input debounce time [μs] 0.1 (0.2 μs, 0.4 μs, 0.8 μs, 1 μs, 2 μs, 4 μs, 8 μs, 10 μs, 50 μs, 100 μs, 500 μs, 1 ms,<br>3 ms, 10 ms, 20 ms parameterisable)<br>Switching logic Inputs Positive logic (PNP)<br>Outputs • Negative logic (NPN)<br>• Positive logic (PNP)<br>• Push-pull driver<br>LED displays Group diagnostics 1<br>Channel diagnostics 2<br>Channel status 10<br>Module diagnostics 2<br>Diagnostics Operating mode-dependent diagnostics<br>Parameterisation • Switch-on/off delay<br>• Frequency output<br>• Speed measurement<br>• Impulse output<br>• Pulse train<br>• Rotational speed measurement<br>• Frequency measurement<br>• Period duration measurement<br>• Motor operating mode<br>• Determine position<br>• Pulse width modulation<br>• One-off counting<br>• Continuous counting<br>• Periodic counting<br>Degree of protection to EN 60529 IP65, IP67<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Certification UL – Recognized (OL)<br>Information on materials: Housing Plastic<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block and connection block) [mm] 50 x 107 x 50<br>W x L x H<br>Product weight [g] 130<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 131 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Counter module, digital ## **Connection and display components** CPX-2ZE2DA ~~1 2~~ - [1] Status LEDs (green) - 3 For allocation to inputs a Pin allocation for module - [2] Status LEDs (yellow, red) For allocation to outputs a Pin allocation for module - [3] Error LED (red, module error) ## **Pin allocation** **==> picture [523 x 236] intentionally omitted <==** **----- Start of picture text -----**<br> Inputs/outputs CPX-2ZE2DA<br>X1 .0 .0 X5 Channel 0 Duct 1<br>.1 .1 X1.0: Input X5.0: Input<br>.2 .2<br>.3 .3 X1.1: Input X5.1: Input<br>.0 .0 X1.2: Input X5.2: Input<br>X2 .1.2 .1.2 X6 X1.3: Input X5.3: Input<br>.3 .3<br>.0 .0 X2.0: Input X6.0: Input<br>X3 .1.2 .1.2 X7 X2.1: Input X6.1: Input<br>.3 .3 X2.2: 5 V DC X6.2: 5 V DC<br>.0 .0<br>.1 .1 X2.3: 0 V X6.3: 0 V<br>.2 .2<br>X4 .3 .3 X8 X3.0: 24 V DC X7.0: 24 V DC<br>X3.1: 0 V X7.1: 0 V<br>X3.2: 24 V DC for digital input DI X7.2: 24 V DC for digital input DI<br>X3.3: Digital input DI X7.3: Digital input DI<br>X4.0: 0 V for digital input DI X8.0: 0 V for digital input DI<br>X4.1: Digital output DO X8.1: Digital output DO<br>X4.2: Reference potential for DO X8.2: Reference potential for DO<br>X4.3: FE X8.3: FE<br>**----- End of picture text -----**<br> ## - **Note** H- The allocation and designation of inputs differs fundamentally depending on which type of encoder is connected. Appropriate allocation diagrams can be found in the user documentation for the counter module. Subject to change – 2023/10 132 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Counter module, digital **==> picture [523 x 171] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Counter module, digital<br>2 digital inputs, 2 digital outputs 576046 CPX-2ZE2DA<br>User documentation<br>User documentation for counter module CPX-2ZE2DA German 8035733 P.BE-CPX-2ZE2DA-DE<br>English 8035734 P.BE-CPX-2ZE2DA-EN<br>Spanish 8035735 P.BE-CPX-2ZE2DA-ES<br>French 8035736 P.BE-CPX-2ZE2DA-FR<br>Italian 8035737 P.BE-CPX-2ZE2DA-IT<br>Chinese 8035738 P.BE-CPX-2ZE2DA-ZH<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 133 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – HART input/output module ## **Function** The HART input/output module allows the connection of up to 4 sensors or actuators. The corresponding communication channel is made available for sensors or actuators that communicate using the HART protocol. ## **Area of application** - Multi I/O module for 24 V DC supply voltage - Supports connection blocks with M12 and terminal connection - Module features can be parameterised With the HART protocol, a conventional • The module receives the voltage analogue 4 ... 20 mA current signal is supply for the electronics, outputs modulated by a second frequenand the sensors from the interlinkcy-modulated signal. ing block Each of the 4 connections of the • Module protection and diagnostics module can be configured as inputs or through integrated electronic outputs. protection **General technical data** Type CPX-4AE-4AA-H Protocol HART Number of selectable analogue inputs/outputs 4 Type of sensor 0 ... 20 mA 4 ... 20 mA 4 ... 20 mA with HART Operating voltage Nominal value [V DC] 24 Permissible range [V DC] 18 ... 30 ~~———~~ Power failure buffering [ms] 10 Intrinsic current consumption at nominal operating voltage [mA] Typically 170 Maximum short circuit current [mA] 22 Maximum open circuit voltage [V] 28.8 Minimum available sensor voltage 20.7 V DC at 20 mA Fuse protection (short circuit) Internal electronic fuse per channel Reverse polarity protection For all electrical connections Galvanic isolation Channel – channel No Channel – internal bus Yes Signal range 0 ... 20 mA 4 ... 20 mA 4 ... 20 mA with HART Data format 15 bits + prefix Scalable to 15 bits Maximum load [Ω] 750 Maximum input resistance [Ω] 300 Maximum cable length [m] 500 Basic error limit at 25°C [%] ±0.1 Operating error limit related to the ambient temperature range [%] ±0.3 Repetition accuracy 0.05% at 20°C LED displays Group diagnostics 1 Channel diagnostics 4 Channel status 4 Control elements DIL switch Diagnostics • Wire break per channel • Limit value violation per channel • Short circuit/overload per channel • Parameterisation error • Overflow/underflow • Limit value violation to NE43 per channel ~~a~~ 134 d **Internet: www.festo.com/catalogue/...** Subject to change – 2023/10 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – HART input/output module **==> picture [523 x 441] intentionally omitted <==** **----- Start of picture text -----**<br> General technical data<br>Parameterisation • Data format<br>• Failsafe per channel<br>• Forcing per channel<br>• Limit value monitoring per channel<br>• Idle mode per channel<br>• Measured value smoothing<br>• Signal range per channel<br>• Monitoring overflow/underflow<br>• Monitoring to NE43, inputs<br>• Monitoring of wire break per channel<br>• Wire break per channel<br>• Limit value violation per channel<br>• Short circuit/overload per channel<br>• Parameterisation error<br>• Overflow/underflow<br>• Limit value violation to NE43 per channel<br>• Number of HART repetitions<br>• Hysteresis for limit values<br>• HART variables (4 pieces)<br>• Behaviour after short circuit/overload<br>Degree of protection to EN 60529 Depending on connection block<br>Technical data – Mechanical components<br>Type of mounting On interlinking block<br>Product weight [g] 77.4<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block and connection block) [mm] 50 x 107 x 70<br>W x L x H<br>Materials<br>Housing PA-reinforced, PC<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Operating and environmental conditions<br>Ambient temperature [°C] –5 ... +50<br>Storage temperature [°C] –20 ... +70<br>Relative humidity [%] 95, non-condensing<br>Corrosion resistance class CRC [1)] 1 (when installed)<br>CE marking (see declaration of conformity) [3)] To EU EMC Directive [2)]<br>**----- End of picture text -----**<br> - 1) More information: www.festo.com/x/topic/kbk 2) For information about the area of use, see the EC declaration of conformity at: www.festo.com/catalogue/... d Support/Downloads. If the devices are subject to usage restrictions in residential, commercial or light-industrial environments, further measures for the reduction of the emitted interference may be necessary. - 3) Additional information: www.festo.com/catalogue/... d Support/Downloads. |**Safety characteristics**<br>Shock resistance<br>Shock test with severitylevel 2 to FN 942017-5 and EN 60068-2-27|**Safety characteristics**<br>Shock resistance<br>Shock test with severitylevel 2 to FN 942017-5 and EN 60068-2-27| |---|---| |Vibration resistance|Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6| 2023/10 – Subject to change 135 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – HART input/output module **==> picture [524 x 354] intentionally omitted <==** **----- Start of picture text -----**<br> Connection and display components<br>CPX-4EA-4AA-H<br>[1] Status LEDs: [3] Error LED (red, module error)<br>3<br>– Inputs (green)<br>– Outputs (yellow)<br>a Pin allocation for module<br>[2] Error LEDs (red)<br>Allocation to inputs/outputs<br>1 2 a Pin allocation for module<br>Combinations of bus nodes/control blocks with HART input/output module<br>Bus node/control block Part no. Protocol Can be combined as of HART variables in process Full HART functionality<br>release image only<br>CPX-CEC-C1-V3 3473128 CODESYS Level 2 3.5.12.174 – h<br>CPX-CEC-M1-V3 3472765 CODESYS Level 2 3.5.12.174 – h<br>CPX-CEC-S1-V3 3472425 CODESYS Level 2 3.5.12.174 – h<br>CPX-FB11 526172 DeviceNet 25 h –<br>CPX-FB13 195740 PROFIBUS 34 – h<br>CPX-FB14 526174 CANopen 30 h –<br>CPX-FB36 1912451 EtherNet/IP 15 – h<br>CPX-FB37 2735960 EtherCAT 7 h –<br>CPX-FB43 8110369 PROFINET RT, M12 45 – h<br>CPX-M-FB44 8110370 PROFINET RT, RJ45 45 – h<br>CPX-M-FB45 8110371 PROFINET RT, SCRJ 45 – h<br>Combinations of connection blocks with HART input/output module<br>Connection blocks Part no. HART input/output module<br>CPX-4EA-4AA-H<br>CPX-P-AB-4XM12-4POL 565706 h<br>CPX-P-AB-2XKL-8POL 565704 h<br>**----- End of picture text -----**<br> Subject to change – 2023/10 136 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – HART input/output module ## **Pin allocation** **==> picture [523 x 315] intentionally omitted <==** **----- Start of picture text -----**<br> Connection block inputs/outputs CPX-4AE-4AA-H<br>Inputs Outputs<br>CPX-P-AB-4XM12-4POL<br>X1.1: 24 VSEN x X3.1: 24 VSEN x+2 X1.1: Output I0+ X3.1: Output I2+<br>X1.2: 0 V X3.2: 0 V X1.2: 0 V X3.2: 0 V<br>X1.3: Input x X3.3: Input x+2 X1.3: – X3.3: –<br>X1.4: 0 V X3.4: 0 V X1.4: 0 V X3.4: 0 V<br>X2.1: 24 VSEN x+1 X4.1: 24 VSEN x+3 X2.1: Output I1+ X4.1: Output I3+<br>X2.2: 0 V X4.2: 0 V X2.2: 0 V X4.2: 0 V<br>X2.3: Input x+1 X4.3: Input x+3 X2.3: – X4.3: –<br>X2.4: 0 V X4.4: 0 V X2.4: 0 V X4.4: 0 V<br>CPX-P-AB-2XKL-8POL<br>X1.1: 24 VSEN x X2.1: 24 VSEN x+2 X1.1: Output I0+ X2.1: Output I2+<br>X1.2: 0 V X2.2: 0 V X1.2: 0 V X2.2: 0 V<br>X1.3: Input x X2.3: Input x+2 X1.3: – X2.3: –<br>X1.4: 0 V X2.4: 0 V X1.4: 0 V X2.4: 0 V<br>X1.5: 24 VSEN x+1 X2.5: 24 VSEN x+3 X1.5: Output I1+ X2.5: Output I3+<br>X1.6: 0 V X2.6: 0 V X1.6: 0 V X2.6: 0 V<br>X1.7: Input x+1 X2.7: Input x+3 X1.7: – X2.7: –<br>X1.8: 0 V X2.8: 0 V X1.8: 0 V X2.8: 0 V<br>**----- End of picture text -----**<br> ## - **Note** H- In the case of mixed operation of inputs and outputs in one module, the connections are first assigned input signals and then output signals, in ascending order. 2023/10 – Subject to change 137 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – HART input/output module **==> picture [524 x 391] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>HART input/output module<br>4 analogue inputs/outputs 8059847 CPX-4AE-4AA-H<br>Connection block<br>Plastic 4x socket, M12, 4-pin 565706 CPX-P-AB-4XM12-4POL<br>2x plug, 8-pin 565704 CPX-P-AB-2XKL-8POL<br>Plugs<br>8-pin socket Spring-loaded terminal Connection cross section 565712 NECU-L3G8-C1<br>0.2 ... 2.5 mm [2]<br>Screw terminal Connection cross section 565710 NECU-L3G8-C2<br>0.2 ... 2.5 mm [2]<br>Plug M12x1, 4-pin, straight, Screw terminal Connection cross section 192008 SEA-4GS-7-2.5<br>A-coded 0.14 ... 0.5 mm [2]<br>Nominal conductor cross section 18666 SEA-GS-7<br>0.14 ... 0.75 mm [2]<br>Permissible cable @ 4 ... 6 mm<br>Connection cross section 0.75 mm [2] 18778 SEA-GS-9<br>Permissible cable @ 6 ... 8 mm<br>Cover<br>Cover cap for sealing unused connections M12x1 (10 pieces) 165592 ISK-M12<br>Coding element<br>To ensure that a coded socket NECU-L3G8 can only be inserted in the matching For NECU-L3G8 565713 CPX-P-KDS-AB-2XKL<br>coded connection block CPX-P-AB-2XKL (96 of each)<br>**----- End of picture text -----**<br> Subject to change – 2023/10 138 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – Input module, analogue ## **Function** ## **Area of application** Analogue modules control devices with • Analogue module for 0 ... 10 V, a standardised analogue interface 0 ... 20 mA or 4 ... 20 mA such as pressure switches, tempera• Supports connection blocks with ture, flow rate, filling level, etc. Sub-D, terminal connection and Depending on the connection block seM12 connection lected, the analogue module supports • Analogue module features can be various connection concepts with difparameterised ferent numbers of sockets or terminals. • Different data formats available - Operation with and without galvanic isolation possible - The analogue module receives the voltage supply for the electronics and the sensors from the interlinking block - Analogue module protection and diagnostics through integrated electronic fuse protection ## **General technical data** |and the sensors from the interlink-<br>ing block<br>• Analogue module protection and<br>diagnostics through integrated<br>electronic fuse protection|and the sensors from the interlink-<br>ing block<br>• Analogue module protection and<br>diagnostics through integrated<br>electronic fuse protection|and the sensors from the interlink-<br>ing block<br>• Analogue module protection and<br>diagnostics through integrated<br>electronic fuse protection|and the sensors from the interlink-<br>ing block<br>• Analogue module protection and<br>diagnostics through integrated<br>electronic fuse protection|and the sensors from the interlink-<br>ing block<br>• Analogue module protection and<br>diagnostics through integrated<br>electronic fuse protection|and the sensors from the interlink-<br>ing block<br>• Analogue module protection and<br>diagnostics through integrated<br>electronic fuse protection| |---|---|---|---|---|---| |**General technical data**<br>Type<br>CPX-2AE-U-I<br>CPX-4AE-U-I<br>CPX-4AE-I<br>Voltage input<br>Current input<br>Voltage input<br>Current input<br>Current input<br>Number of analogue inputs<br>2<br>4<br>4<br>~~se~~<br>~~a~~|||||| ||Voltage input<br>Current input<br>2<br>~~se~~<br>~~a~~||Voltage input<br>Current input<br>4<br>~~se~~<br>~~a~~||Current input<br>4<br>~~se~~<br>~~a~~| |Max.power supply per module<br>[A]<br>~~a~~|0.7<br>~~a~~||||| |Fuseprotection<br>~~a~~<br>~~a~~|Internal electronic fuse<br>~~a~~<br>~~a~~||||| |Current consumption from 24 V sensor supply(quiescent current)<br>[mA]<br>~~a~~<br>~~a~~|Typically50<br>~~a~~<br>~~a~~||||| |Current consumption from 24 V sensor supply(at full load)<br>[A]<br>~~a~~<br>~~a~~|Max. 0.7<br>~~a~~<br>~~a~~||||| |Nominal operatingvoltage for load voltage<br>[V DC]<br>~~a~~|24 ±2%<br>~~a~~||||| |Nominal operatingvoltage<br>[V DC]<br>~~a~~|24<br>~~a~~||||| |Operatingvoltage range<br>[V DC]<br>~~a~~|18 ... 30<br>~~a~~||||| |Signal range (parameterisable for each channel with<br>DIL switch or software)|0 ... 10 V|0 ... 20 mA<br>4 ... 20 mA|1 ... 5 V<br>0 ... 10 V<br>–5 ... +5 V<br>–10 ... +10 V|0 ... 20 mA<br>4 ... 20 mA<br>–20 ... +20 mA|0 ... 20 mA<br>4 ... 20 mA| |Operational error limit<br>[%]|±0.5|–|±0.3<br>~~(GO~~|±0.3<br>~~(GO~~|±0.6| |Basic error limit (at 25°C)<br>[%]<br>~~GD~~|±0.3<br>~~GD~~|–<br>~~GD~~|±0.2<br>~~GD~~<br>~~(GO~~|±0.2<br>~~GD~~<br>~~(GO~~<br>~~(OO~~|±0.5<br>~~GD~~| |Repetition accuracy(at 25°C)<br>[%]<br>~~GD~~<br>~~GO~~|0.15<br>~~GD~~<br>~~GO~~|0.15<br>~~GD~~<br>~~GO~~|0.1<br>~~GD~~<br>~~(GO~~<br>~~GO~~|0.1<br>~~GD~~<br>~~(GO~~<br>~~GO~~<br>~~(OO~~|0.15<br>~~GD~~<br>~~GO~~| |Input resistance<br>~~GO~~<br>~~GG~~|100 kΩ<br>~~GO~~<br>~~GG~~<br>~~GD~~|š100 Ω<br>~~GO~~<br>~~GG~~<br>~~GD~~|100 kΩ<br>~~GO~~<br>~~GG~~<br>~~(CO~~|š100 Ω<br>~~GO~~<br>~~(OO~~<br>~~GG~~<br>~~(CO~~|š100 Ω<br>~~GO~~<br>~~GG~~| |Max.permissible input voltage<br>[V DC]<br>~~a~~|30<br>~~a~~<br>~~GD~~|–<br>~~a~~<br>~~GD~~|–30 ... +30<br>~~a~~<br>~~(CO~~|–<br>~~a~~<br>~~(CO~~|–<br>~~a~~| |Max. permissible input current<br>[mA]<br>~~a~~<br>~~ee~~|–<br>~~a~~<br>~~GD~~<br>~~ee~~|40<br>~~a~~<br>~~GD~~<br>~~ee~~|–<br>~~a~~<br>~~(CO~~<br>~~ee~~|Internally limited<br>to 60<br>~~a~~<br>~~(CO~~<br>~~ee~~|Internally limited<br>40<br>~~a~~<br>~~ee~~| |Conversion timeper channel<br>[μs]<br>~~a~~|Typically150<br>~~a~~||||| |Cycle time (module)<br>[ms]<br>~~a~~|š4<br>~~a~~<br>~~ee~~||š0.5<br>~~a~~<br>||š10<br>~~a~~<br>| |Data format<br>~~a~~~~**e**~~|12 bits +prefix<br>~~**e**~~<br>~~ee~~||15 bits +prefix<br>~~**e**~~<br><br>~~ee~~||12 bits +prefix<br>~~**e**~~<br>| ||Scalable to 15 bits<br>~~**e**~~<br>~~ee ~~||Scalable to 15 bits<br>~~**e**~~<br> ~~e~~<br>~~ee~~||Scalable to<br>15 bits<br>~~**e**~~<br>~~e~~| |Cable length<br>[m]|Max. 30 (shielded)<br>~~ee ~~<br>~~ee~~||||| 2023/10 – Subject to change 139 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, analogue ## **General technical data** **==> picture [524 x 343] intentionally omitted <==** **----- Start of picture text -----**<br> Type CPX-2AE-U-I CPX-4AE-U-I CPX-4AE-I<br>Galvanic isolation Channel – channel No<br>Channel – internal bus Yes, with external sensor supply<br>LED displays Group diagnostics 1<br>Channel diagnostics Via flashing frequency of 4 Via flashing frequency of<br>group diagnostics group diagnostics<br>Diagnostics Wire break per channel<br>Limit value violation per channel<br>Parameterisation error<br>Short circuit, input signal Overload at input Short circuit, input signal<br>– –<br>Overflow/underflow<br>– Short circuit in sensor –<br>supply<br>Parameterisation Data format<br>Forcing per channel<br>Limit value monitoring per channel<br>Measured value smoothing<br>Signal range per channel<br>Monitoring of wire break per channel<br>Behaviour after short circuit<br>– Behaviour after overload at –<br>input<br>– Sensor supply active –<br>Degree of protection to EN 60529 Depending on connection block<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Materials PA-reinforced, PC<br>Note on materials – RoHS-compliant –<br>PWIS conformity VDMA24364-B2-L VDMA24364-B2-L VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block and connection block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 48 46 47<br>**----- End of picture text -----**<br> Subject to change – 2023/10 140 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, analogue ## **Connection and display components** CPX-2AE-U-I and CPX-4AE-I CPX-4AE-U-I [1] Error LED (red; module error) [1] Error LED (red; module error) 1 1 [2] Channel-related error LEDs (red) ~~2~~ **==> picture [523 x 520] intentionally omitted <==** **----- Start of picture text -----**<br> Combinations of connection blocks and analogue module<br>Connection blocks Part no. Analogue module<br>CPX-2AE-U-I CPX-4AE-U-I CPX-4AE-I<br>CPX-AB-4-M12X2-5POL 195704 h h h<br>CPX-AB-4-M12X2-5POL-R 541254 h h h<br>CPX-AB-8-KL-4POL 195708 h h h<br>CPX-AB-1-SUB-BU-25POL 525676 h h h<br>CPX-M-AB-4-M12X2-5POL 549367 h h h<br>Pin allocation<br>Connection block inputs CPX-2AE-U-I CPX-4AE-U-I CPX-4AE-I<br>CPX-AB-4-M12X2-5POL, CPX-AB-4-M12X2-5POL-R [1)] and CPX-M-AB-4-M12X2-5POL<br>X1.1: 24 VSEN X3.1: 24 VSEN X1.1: 24 VSEN X3.1: 24 VSEN X1.1: 24 VSEN X3.1: 24 VSEN<br>X1.2: Input U0+ X3.2: Input U1+ X1.2: Input 0+ X3.2: Input 2+ X1.2: Input I0+ X3.2: Input I2+<br>X1.3: 0 VSEN X3.3: 0 VSEN X1.3: 0 VSEN X3.3: 0 VSEN X1.3: 0 VSEN X3.3: 0 VSEN<br>X1.4: Input U0– X3.4: Input U1– X1.4: Input 0– X3.4: Input 2– X1.4: Input I0– X3.4: Input I2–<br>X1.5: FE [2)] X3.5: FE [2)] X1.5: FE [2)] X3.5: FE [2)] X1.5: FE [2)] X3.5: FE [2)]<br>X2.1: 24 VSEN X4.1: 24 VSEN X2.1: 24 VSEN X4.1: 24 VSEN X2.1: 24 VSEN X4.1: 24 VSEN<br>X2.2: Input I0+ X4.2: Input I1+ X2.2: Input 1+ X4.2: Input 3+ X2.2: Input I1+ X4.2: Input I3+<br>X2.3: 0 VSEN X4.3: 0 VSEN X2.3: 0 VSEN X4.3: 0 VSEN X2.3: 0 VSEN X4.3: 0 VSEN<br>X2.4: Input I0– X4.4: Input I1– X2.4: Input 1– X4.4: Input 3– X2.4: Input I1– X4.4: Input I3–<br>X2.5: FE [2)] X4.5: FE [2)] X2.5: FE [2)] X4.5: FE [2)] X2.5: FE [2)] X4.5: FE [2)]<br>CPX-AB-8-KL-4POL<br>X1 .0 .0 X5 X1.0: 24 VSEN X5.0: 24 VSEN X1.0: 24 VSEN X5.0: 24 VSEN X1.0: 24 VSEN X5.0: 24 VSEN<br>.1.2 .1.2 X1.1: 0 VSEN X5.1: 0 VSEN X1.1: 0 VSEN X5.1: 0 VSEN X1.1: 0 VSEN X5.1: 0 VSEN<br>.3 .3 X1.2: Input U0– X5.2: Input U1– X1.2: Input 0– X5.2: Input 2– X1.2: Input I0– X5.2: Input I2–<br>.0 .0 X1.3: FE X5.3: FE X1.3: FE X5.3: FE X1.3: FE X5.3: FE<br>X2 .1 .1 X6<br>.2 .2<br>X2.0: n.c. X6.0: n.c. X2.0: n.c. X6.0: n.c. X2.0: n.c. X6.0: n.c.<br>.3 .3<br>.0 .0 X2.1: n.c. X6.1: n.c. X2.1: n.c. X6.1: n.c. X2.1: n.c. X6.1: n.c.<br>X3 .1.2 .1.2 X7 X2.2: Input U0+ X6.2: Input U1+ X2.2: Input 0+ X6.2: Input 2+ X2.2: Input I0+ X6.2: Input I2+<br>.3 .3 X2.3: FE X6.3: FE X2.3: FE X6.3: FE X2.3: FE X6.3: FE<br>.0 .0<br>.1.2 .1.2 X3.0: 24 VSEN X7.0: 24 VSEN X3.0: 24 VSEN X7.0: 24 VSEN X3.0: 24 VSEN X7.0: 24 VSEN<br>X4 .3 .3 X8 X3.1: 0 VSEN X7.1: 0 VSEN X3.1: 0 VSEN X7.1: 0 VSEN X3.1: 0 VSEN X7.1: 0 VSEN<br>X3.2: Input I0– X7.2: Input I1– X3.2: Input 1– X7.2: Input 3– X3.2: Input I1– X7.2: Input I3–<br>X3.3: FE X7.3: FE X3.3: FE X7.3: FE X3.3: FE X7.3: FE<br>X4.0: n.c. X8.0: n.c. X4.0: n.c. X8.0: n.c. X4.0: n.c. X8.0: n.c.<br>X4.1: n.c. X8.1: n.c. X4.1: n.c. X8.1: n.c. X4.1: n.c. X8.1: n.c.<br>X4.2: Input I0+ X8.2: Input I1+ X4.2: Input 1+ X8.2: Input 3+ X4.2: Input I1+ X8.2: Input I3+<br>X4.3: FE X8.3: FE X4.3: FE X8.3: FE X4.3: FE X8.3: FE<br>**----- End of picture text -----**<br> - 1) Speedcon quick lock, additional shielding on metal thread - 2) FE/shield additionally on metal thread 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 141 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, analogue ## **Pin allocation** **==> picture [524 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> Connection block inputs CPX-2AE-U-I CPX-4AE-U-I CPX-4AE-I<br>CPX-AB-1-SUB-BU-25POL<br>1: Input U0– 14: Input U1– 1: Input 0– 14: Input 2– 1: Input I0– 14: Input I2–<br>2: Input U0+ 15: Input U1+ 2: Input 0+ 15: Input 2+ 2: Input I0+ 15: Input I2+<br>3: Input I0– 16: Input I1– 3: Input 1– 16: Input 3– 3: Input I1– 16: Input I3–<br>4: Input I1+ 17: Input I1+ 4: Input 1+ 17: Input 3+ 4: Input I1+ 17: Input I3+<br>5: n.c. 18: 24 VSEN 5: n.c. 18: 24 VSEN 5: n.c. 18: 24 VSEN<br>6: n.c. 19: n.c. 6: n.c. 19: n.c. 6: n.c. 19: n.c.<br>7: n.c. 20: 24 VSEN 7: n.c. 20: 24 VSEN 7: n.c. 20: 24 VSEN<br>8: n.c. 21: n.c. 8: n.c. 21: n.c. 8: n.c. 21: n.c.<br>9: 24 VSEN 22: 0 VSEN 9: 24 VSEN 22: 0 VSEN 9: 24 VSEN 22: 0 VSEN<br>10: 24 VSEN 23: 0 VSEN 10: 24 VSEN 23: 0 VSEN 10: 24 VSEN 23: 0 VSEN<br>11: 0 VSEN 24: 0 VSEN 11: 0 VSEN 24: 0 VSEN 11: 0 VSEN 24: 0 VSEN<br>12: 0 VSEN 25: FE 12: 0 VSEN 25: FE 12: 0 VSEN 25: FE<br>13: Shielding [1)] Housing: FE 13: Shielding [1)] Housing: FE 13: Shielding [1)] Housing: FE<br>**----- End of picture text -----**<br> 1) Connect shield to functional earth FE Subject to change – 2023/10 142 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, analogue ## **Ordering data** **==> picture [523 x 520] intentionally omitted <==** **----- Start of picture text -----**<br> Designation Part no. Type<br>Input module, analogue<br>2 analogue current or voltage inputs 526168 CPX-2AE-U-I<br>4 analogue current or voltage inputs 573710 CPX-4AE-U-I<br>4 analogue current inputs 541484 CPX-4AE-I<br>Connection block<br>Plastic 4x socket, M12, 5-pin 195704 CPX-AB-4-M12X2-5POL<br>4x socket, M12 with quick-lock technology, 5-pin 541254 CPX-AB-4-M12X2-5POL-R<br>Spring-loaded terminal, 32-pin 195708 CPX-AB-8-KL-4POL<br>1x Sub-D socket, 25-pin 525676 CPX-AB-1-SUB-BU-25POL<br>Metal 4x socket, M12, 5-pin 549367 CPX-M-AB-4-M12X2-5POL<br>Plug<br>M12, 5-pin PG7, for cable @ 4 ... 6 mm 175487 SEA-M12-5GS-PG7<br>Sub-D, 25-pin 527522 SD-SUB-D-ST25<br>Connecting cable<br>Modular system for a choice of connecting cables – NEBU-...<br>a Internet: nebu<br>Cover<br>Cover for CPX-AB-8-KL-4POL (IP65/67) • 8 cable through feeds M9 538219 AK-8KL<br>• 1 cable through feed for multi-pin<br>plug<br>Fittings kit for cover AK-8KL 538220 VG-K-M9<br>Cover cap for closing off unused M12 connections (10 pieces) 165592 ISK-M12<br>Screening plate<br>Screening plate for connection block 526184 CPX-AB-S-4-M12<br>• CPX-AB-4-M12X2-5POL<br>• CPX-AB-4-M12X2-5POL-R<br>User documentation<br>User documentation German 526415 P.BE-CPX-AX-DE<br>English 526416 P.BE-CPX-AX-EN<br>Spanish 526417 P.BE-CPX-AX-ES<br>French 526418 P.BE-CPX-AX-FR<br>Italian 526419 P.BE-CPX-AX-IT<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 143 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – Input module, analogue, with pressure sensors ## **Function** The pressure input modules make it possible to process a maximum of 4 pressures. The internal measured value of the sensor (analogue value with 10-bit resolution) is converted into an internal numerical format as appropriate to the parameterisation and made available to the bus node as a process image. It is additionally also possible to combine 2 channels in each case to form a differential pressure channel. ## **Area of application** - Measuring range: 0 ... 10 bar or –1 ... +1 bar - Choice of units of measurement - Processing a maximum of 4 pressures per module - Pressure indication via LCD display - Direct connection via QS4 push-in connectors - Error message via CPX-P - Channel-oriented diagnostics ## **General technical data** |ate to the parameterisation and made<br>available to the bus node as a process<br>image. It is additionally also possible<br>to combine 2 channels in each case to<br>form a differential pressure channel.<br>• Direct connection via QS4 push-in<br>connectors<br>• Error message via CPX-P<br>• Channel-oriented diagnostics|ate to the parameterisation and made<br>available to the bus node as a process<br>image. It is additionally also possible<br>to combine 2 channels in each case to<br>form a differential pressure channel.<br>• Direct connection via QS4 push-in<br>connectors<br>• Error message via CPX-P<br>• Channel-oriented diagnostics|ate to the parameterisation and made<br>available to the bus node as a process<br>image. It is additionally also possible<br>to combine 2 channels in each case to<br>form a differential pressure channel.<br>• Direct connection via QS4 push-in<br>connectors<br>• Error message via CPX-P<br>• Channel-oriented diagnostics| |---|---|---| |**General technical data**<br>Type<br>CPX-4AE-P-B2<br>CPX-4AE-P-D10<br>Number of analogue inputs<br>4||| |Pneumatic connection|QS-4|| |Nominal operatingvoltage<br>[V DC]|24|| |Operatingvoltage range<br>[V DC]|18 ... 30|| |Intrinsic current consumption<br>[mA]|Typically50|| |Measured variable|4 x relative or 2 x differentialpressure measurement|| |Displayable units|• kPa<br>• mbar<br>•psi|| |Pressure measuring range<br>Start value<br>[bar]<br>Final value<br>[bar]|–1|0| ||1|10| |Internal cycle time<br>[ms]|5|| |Data format|• 15 bits + prefix<br>• Binarynotation in mbar, kPa,psi|| |LED displays|Groupdiagnostics|| |Diagnostics|• Limit value violation per channel<br>• Parameterisation error<br>• Sensor limitper channel|| |Parameterisation|• Diagnostic delay per channel<br>• Hysteresis per module<br>• Unit of measurement<br>• Measured value smoothing per channel<br>• Limit value monitoring per channel<br>• Sensor limit per channel<br>• Measurement of relative/differentialpressure|| |Degree ofprotection to EN 60529|IP65, IP67|| |Operatingmedium|Compressed air to ISO 8573-1:2010 [7:4:4]|| |Note on the operating/pilot medium|Lubricated operationpossible (in which case lubricated operation will always be required)|| |Ambient temperature<br>[°C]|–5 ... 50|| |Storage temperature<br>[°C]|–20 ... 70|| |Temperature of medium<br>[°C]|0 ... 50|| |Materials|PA-reinforced, PC|| |Note on materials|RoHS-compliant|| |PWIS conformity|VDMA24364-B2-L|| |Grid dimension<br>[mm]|50|| |Dimensions (includinginterlinkingblock) W x L x H<br>[mm]|50 x 107 x 55|| |Product weight<br>[g]|115|| ## - **Note** H- Extreme pneumatic conditions, e.g. high cycle rate with high pressure amplitudes, can damage the sensors. Subject to change – 2023/10 d **Internet: www.festo.com/catalogue/...** 144 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** Data sheet – Input module, analogue, with pressure sensors **==> picture [525 x 395] intentionally omitted <==** **----- Start of picture text -----**<br> Connection and display components<br>1 [1] Error LED (red; module error)<br>[2] LCD display with permanent dis-<br>2<br>play of the four measured pres-<br>sures, unit of measurement and if<br>applicable limit value violation<br>[3] QS connections<br>3<br>Ordering data<br>Designation Part no. Type<br>Input module, analogue<br>4 analogue pressure inputs, pressure range –1 ... +1 bar 560361 CPX-4AE-P-B2<br>4 analogue pressure inputs, pressure range 0 ... 10 bar 560362 CPX-4AE-P-D10<br>Inscription labels<br>Inscription labels 6x10 mm, 64 pieces, in frame 18576 IBS-6x10<br>User documentation<br>User documentation German 526415 P.BE-CPX-AX-DE<br>English 526416 P.BE-CPX-AX-EN<br>Spanish 526417 P.BE-CPX-AX-ES<br>French 526418 P.BE-CPX-AX-FR<br>Italian 526419 P.BE-CPX-AX-IT<br>**----- End of picture text -----**<br> 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 145 Terminal CPX-P ## Data sheet – Input module, analogue, for temperature inputs ## **Function** The CPX-PT100 analogue input module with 4 channels for temperature measurement enables the connection of up to 4 temperature sensors of the type PT100-PT1000, Ni100-Ni1000, etc. The temperature module supports various connection concepts with different numbers of sockets or terminals as appropriate to the connection block selected. ## **Area of application** - Temperature module for temperature sensors PT100, PT200, PT500, PT1000, Ni100, Ni120, Ni500, Ni1000 - Supports connection blocks with M12 and terminal connection - Temperature module features can be parameterised - 2-wire, 3-wire and 4-wire connection - The temperature module is provided with voltage supply for the electronics and the sensors via the interlinking block - Temperature module protection and diagnostics through integrated electronic fuse protection ## **General technical data** |ics and the sensors via the interlink-<br>ing block<br>• Temperature module protection and<br>diagnostics through integrated<br>electronic fuse protection|ics and the sensors via the interlink-<br>ing block<br>• Temperature module protection and<br>diagnostics through integrated<br>electronic fuse protection| |---|---| |**General technical data**<br>Type<br>CPX-4AE-T<br>Temperature input<br>Number of analogue inputs<br>Choice of 2 or 4|| ||Temperature input<br>Choice of 2 or 4| |Max.power supply per module<br>[A]|0.7| |Fuseprotection|Internal electronic fuse for sensor supply| |Current consumption from 24 V sensor supply(quiescent current)<br>[mA]|Typically50| |Sensor supplyvoltage<br>[V DC]|24 ±25%| |Sensor type (parameterisable for each channel with DIL switch)|PT100, PT200, PT500, PT1000<br>Ni100, Ni120, Ni500, Ni1000| |Temperature range<br>Pt standard<br>[°C]<br>Pt climatic<br>[°C]<br>Ni<br>[°C]|–200 ... +850| ||–120 ... +130| ||–60 ... +180| |Sensor connection technology|2-wire, 3-wire and 4-wire technology| |Resolution|15 bits +prefix| |Operatingerror limit relative to input range<br>[%]|±0.06| |Basic error limit (25°C)<br>Standard<br>[K]<br>Pt climatic<br>[K]|±0.6| ||±0.2| |Temperature errors relative to input range<br>[%]|±0.001| |Linearityerrors (no software scaling)<br>[%]|±0.02| |Repetition accuracy(at 25°C)<br>[%]|±0.05| |Max. line resistanceper conductor<br>[Ω]|10| |Max.permissible input voltage<br>[V]|±30| |Cycle time (module)<br>[ms]|š250| Subject to change – 2023/10 146 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, analogue, for temperature inputs **==> picture [523 x 287] intentionally omitted <==** **----- Start of picture text -----**<br> General technical data<br>Data format 15 bits + prefix, complement of two, binary notation in tenths of a degree<br>Cable length [m] Max. 200 (shielded)<br>Galvanic isolation Channel – channel No<br>Channel – internal bus Yes<br>LED displays Group diagnostics 1<br>Channel diagnostics 4<br>Diagnostics • Short circuit/overload, channel<br>• Parameterisation error<br>• Value falling below nominal range/full-scale value<br>• Value exceeding nominal range/full-scale value<br>• Wire break<br>Parameterisation • Unit of measurement and interference frequency suppression<br>• Diagnostic message in the event of a wire break or short circuit<br>• Limit monitoring per channel<br>• Sensor connection technology<br>• Sensor type/temperature coefficient, temperature range<br>• Limit value per channel<br>• Measured value smoothing<br>Degree of protection to EN 60529 Depending on connection block<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Materials PA-reinforced, PC<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block and connection block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 47<br>**----- End of picture text -----**<br> **Connection and display components** CPX-4AE-T [1] Error LED (red; module error) 1 [2] Channel-related error LEDs (red) ~~2~~ |~~2~~|~~2~~|| |---|---|---| |**Combinations of connection blocks and analogue module**<br>Connection blocks<br>Part no.<br>CPX-AB-4-M12X2-5POL<br>**195704**||Temperature module| |||CPX-4AE-T<br>h| |CPX-AB-4-M12X2-5POL-R|**541254**|h| |CPX-AB-8-KL-4POL|**195708**|h| |CPX-M-AB-4-M12X2-5POL|**549367**|h| 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 147 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, analogue, for temperature inputs ## **Pin allocation** **==> picture [524 x 403] intentionally omitted <==** **----- Start of picture text -----**<br> Connection block inputs CPX-4AE-T<br>CPX-AB-4-M12X2-5POL, CPX-AB-4-M12X2-5POL-R [1)] and CPX-M-AB-4-M12X2-5POL<br>X1.1: Input I0+ X3.1: Input I2+<br>X1.2: Input U0+ X3.2: Input U2+<br>X1.3: Input I0– X3.3: Input I2–<br>X1.4: Input U0– X3.4: Input U2–<br>X1.5: FE [2)] X3.5: FE [2)]<br>X2.1: Input I1+ X4.1: Input I3+<br>X2.2: Input U1+ X4.2: Input U3+<br>X2.3: Input I1– X4.3: Input I3–<br>X2.4: Input U1– X4.4: Input U3–<br>X2.5: FE [2)] X4.5: FE [2)]<br>CPX-AB-8-KL-4POL<br>X1 .0 .0 X5 X1.0: Input I0+ X5.0: Input I2+<br>.1 .1 X1.1: Input I0– X5.1: Input I2–<br>.2 .2<br>.3 .3 X1.2: Input U0– X5.2: Input U2–<br>.0 .0 X1.3: FE X5.3: FE<br>X2 .1 .1 X6<br>.2 .2<br>X2.0: n.c. X6.0: n.c.<br>.3 .3<br>.0 .0 X2.1: n.c. X6.1: n.c.<br>X3 .1.2 .1.2 X7 X2.2: Input U0+ X6.2: InputUI2+<br>.3 .3 X2.3: FE X6.3: FE<br>.0 .0<br>.1.2 .1.2 X3.0: Input I1+ X7.0: Input I3+<br>X4 .3 .3 X8 X3.1: Input I1– X7.1: Input I3–<br>X3.2: Input U1– X7.2: Input U3–<br>X3.3: FE X7.3: FE<br>X4.0: n.c. X8.0: n.c.<br>X4.1: n.c. X8.1: n.c.<br>X4.2: Input U1+ X8.2: Input U3+<br>X4.3: FE X8.3: FE<br>**----- End of picture text -----**<br> - 1) Speedcon quick lock, additional shielding on metal thread 2) FE/shield additionally on metal thread Subject to change – 2023/10 148 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, analogue, for temperature inputs **==> picture [523 x 411] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Input module, analogue<br>2 or 4 analogue temperature inputs 541486 CPX-4AE-T<br>Connection block<br>Plastic 4x socket M12, 5-pin 195704 CPX-AB-4-M12X2-5POL<br>4x socket, M12 with quick-lock technology, 5-pin 541254 CPX-AB-4-M12X2-5POL-R<br>Spring-loaded terminal, 32-pin 195708 CPX-AB-8-KL-4POL<br>Metal 4x socket M12, 5-pin 549367 CPX-M-AB-4-M12X2-5POL<br>Plug<br>M12, 5-pin PG7, for cable @ 4 ... 6 mm 175487 SEA-M12-5GS-PG7<br>Cover<br>Cover for CPX-AB-8-KL-4POL (IP65, IP67) • 8 cable through feeds M9 538219 AK-8KL<br>• 1 cable through feed for multi-pin<br>plug<br>Fittings kit 538220 VG-K-M9<br>Screening plate<br>Screening plate for M12 connections 526184 CPX-AB-S-4-M12<br>User documentation<br>User documentation German 526415 P.BE-CPX-AX-DE<br>English 526416 P.BE-CPX-AX-EN<br>Spanish 526417 P.BE-CPX-AX-ES<br>French 526418 P.BE-CPX-AX-FR<br>Italian 526419 P.BE-CPX-AX-IT<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 149 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – Input module, analogue, for thermocouple ## **Function** ## **Area of application** The CPX-4AE-TC analogue input module • Supports connection blocks with with 4 channels for temperature measM12 and terminal connection urement enables up to 4 thermocouple • Temperature module features can sensors to be connected. be parameterised The channels feature wire break and • 2-wire connection short circuit detection. • 2-wire connection for a PT1000 senIf no cold junction compensation sor for cold junction compensation sensor is being used, an internal • The temperature module is provided theoretical value of 25°C can be used with voltage supply for the electron(accuracy is impaired). ics and the sensors via the interlinking block • Temperature module protection and diagnostics through integrated electronic fuse protection ## **General technical data** |(accuracy is impaired).<br>ics and the sensors via the interlink-<br>ing block<br>• Temperature module protection and<br>diagnostics through integrated<br>electronic fuse protection|(accuracy is impaired).<br>ics and the sensors via the interlink-<br>ing block<br>• Temperature module protection and<br>diagnostics through integrated<br>electronic fuse protection| |---|---| |**General technical data**<br>Type<br>CPX-4AE-TC<br>Temperature input<br>Number of analogue inputs<br>4|| ||Temperature input<br>4| |Fuseprotection (short circuit)|Internal electronic fuseper channel| |Nominal operatingvoltage<br>[V DC]|24| |Operatingvoltage range<br>[V DC]|18 ... 30| |Sensor type (parameterisable for each channel with software)|• Type B +400 ... +1820°C, 8 μV/°C<br>• Type E –270 ... +900°C, 60 μV/°C<br>• Type J –200 ... +1200°C, 51 μV/°C<br>• Type K –200 ... +1370°C, 40 μV/°C<br>• Type N –200 ... +1300°C, 38 μV/°C<br>• Type R 0 ... +1760°C, 12 μV/°C<br>• Type S 0 ... +1760°C, 11 μV/°C<br>• Type T –200 ... +400°C, 40μV/°C| |Sensor connection technology|2-wire technology| |Operatingerror limit relative to ambient temperature<br>[%]|Max. ±0.6| |Basic error limit (at 25°C)<br>[%]|Max. ±0.4| |Repetition accuracy(at 25°C)<br>[%]|±0.05| |Max. line resistanceper conductor<br>[Ω]|10| |Max. residual currentper module<br>[mA]|30| |Max.permissible input voltage<br>[V]|±30| |Internal cycle time (module)<br>[ms]|250| Subject to change – 2023/10 150 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, analogue, for thermocouple **==> picture [523 x 267] intentionally omitted <==** **----- Start of picture text -----**<br> General technical data<br>Data format • 15 bits + prefix, complement of two<br>• Binary notation in tenths of a degree<br>Cable length [m] Max. 50 (shielded)<br>Galvanic isolation Channel – channel No<br>Channel – internal bus Yes<br>LED displays Group diagnostics 1<br>Channel diagnostics 4<br>Diagnostics • Parameterisation error<br>• Wire break per channel<br>• Limit value violation per channel<br>Parameterisation • Monitoring of wire break per channel<br>• Unit of measurement<br>• Cold-junction compensation<br>• Sensor type per channel<br>• Limit value monitoring per channel<br>• Measured value smoothing<br>Degree of protection to EN 60529 Depending on connection block<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Materials PA-reinforced, PC<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block and connection block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 46<br>**----- End of picture text -----**<br> **Connection and display components** CPX-4AE-TC [1] Error LED (red; module error) 1 [2] Channel-related error LEDs (red) ~~2~~ ## **Combinations of connection blocks and analogue module** |~~2~~|~~2~~|~~2~~| |---|---|---| |**Combinations of connection blocks and analogue module**||| |Connection blocks<br>CPX-AB-4-M12X2-5POL|Part no.<br>**195704**|Temperature module| |||CPX-4AE-TC<br>h| |CPX-AB-4-M12X2-5POL-R|**541254**|h| |CPX-AB-8-KL-4POL|**195708**|h| |CPX-M-AB-4-M12X2-5POL|**549367**|h| 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 151 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, analogue, for thermocouple ## **Pin allocation** **==> picture [524 x 404] intentionally omitted <==** **----- Start of picture text -----**<br> Connection block inputs CPX-4AE-TC<br>CPX-AB-4-M12X2-5POL, CPX-AB-4-M12X2-5POL-R [1)] and CPX-M-AB-4-M12X2-5POL<br>X1.1: Cold junction compensation 0+ X3.1: Cold junction compensation 2+<br>X1.2: Input signal U0+ X3.2: Input signal U2+<br>X1.3: Cold junction compensation 0– X3.3: Cold junction compensation 2–<br>X1.4: Input signal U0– X3.4: Input signal U2–<br>X1.5: FE [2)] X3.5: FE [2)]<br>X2.1: Cold junction compensation 1+ X4.1: Cold junction compensation 3+<br>X2.2: Input signal U1+ X4.2: Input signal U3+<br>X2.3: Cold junction compensation 1– X4.3: Cold junction compensation 3–<br>X2.4: Input signal U1– X4.4: Input signal U3–<br>X2.5: FE [2)] X4.5: FE [2)]<br>CPX-AB-8-KL-4POL<br>X1 .0 .0 X5 X1.0: Cold junction compensation 0+ X5.0: Cold junction compensation 2+<br>.1 .1 X1.1: Cold junction compensation 0– X5.1: Cold junction compensation 2–<br>.2 .2<br>.3 .3 X1.2: Input signal U0– X5.2: Input signal U2–<br>.0 .0 X1.3: FE X5.3: FE<br>X2 .1 .1 X6<br>.2 .2<br>X2.0: n.c. X6.0: n.c.<br>.3 .3<br>.0 .0 X2.1: n.c. X6.1: n.c.<br>X3 .1.2 .1.2 X7 X2.2: Input signal U0+ X6.2: Input signal U2+<br>.3 .3 X2.3: FE X6.3: FE<br>.0 .0<br>.1.2 .1.2 X3.0: Cold junction compensation 1+ X7.0: Cold junction compensation 3+<br>X4 .3 .3 X8 X3.1: Cold junction compensation 1– X7.1: Cold junction compensation 3–<br>X3.2: Input signal U1– X7.2: Input signal U3–<br>X3.3: FE X7.3: FE<br>X4.0: n.c. X8.0: n.c.<br>X4.1: n.c. X8.1: n.c.<br>X4.2: Input signal U1+ X8.2: Input signal U3+<br>X4.3: FE X8.3: FE<br>**----- End of picture text -----**<br> - 1) Speedcon quick lock, additional shielding on metal thread - 2) FE/shield additionally on metal thread Subject to change – 2023/10 152 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Input module, analogue, for thermocouple **==> picture [523 x 460] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Input module, analogue<br>4 analogue temperature inputs, with 2-wire connection for a PT1000 sensor for cold junction 553594 CPX-4AE-TC<br>compensation<br>Connection block<br>Plastic 4x socket M12, 5-pin 195704 CPX-AB-4-M12X2-5POL<br>4x socket, M12 with quick-lock technology, 5-pin 541254 CPX-AB-4-M12X2-5POL-R<br>Spring-loaded terminal, 32-pin 195708 CPX-AB-8-KL-4POL<br>Metal 4x socket M12, 5-pin 549367 CPX-M-AB-4-M12X2-5POL<br>Cold junction compensation<br>PT1000 temperature sensor for cold junction compensation 553596 CPX-W-PT1000<br>Plug<br>M12, 5-pin PG7, for cable @ 4 ... 6 mm 175487 SEA-M12-5GS-PG7<br>Cover<br>Cover for CPX-AB-8-KL-4POL (IP65, IP67) • 8 cable through feeds M9 538219 AK-8KL<br>• 1 cable through feed for multi-pin<br>plug<br>Fittings kit 538220 VG-K-M9<br>Screening plate<br>Screening plate for M12 connections 526184 CPX-AB-S-4-M12<br>User documentation<br>User documentation German 526415 P.BE-CPX-AX-DE<br>English 526416 P.BE-CPX-AX-EN<br>Spanish 526417 P.BE-CPX-AX-ES<br>French 526418 P.BE-CPX-AX-FR<br>Italian 526419 P.BE-CPX-AX-IT<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 153 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – Output module, analogue ## **Function** Analogue modules control devices with a standard analogue interface such as proportional valves, etc. Depending on the connection block selected, the analogue module supports various connection concepts with different numbers of sockets or terminals. ## **Area of application** - Analogue module for 0 ... 10 V, 0 ... 20 mA or 4 ... 20 mA - Supports connection blocks with Sub-D, terminal connection and M12 connection - Analogue module features can be parameterised - Different data formats available - Operation with and without galvanic isolation possible - The analogue module receives the voltage supply for the electronics and the actuators from the interlinking block - Analogue module protection and diagnostics through integrated electronic fuse protection ## **General technical data** |and the actuators from the interlink-<br>ing block<br>• Analogue module protection and<br>diagnostics through integrated<br>electronic fuse protection|and the actuators from the interlink-<br>ing block<br>• Analogue module protection and<br>diagnostics through integrated<br>electronic fuse protection|and the actuators from the interlink-<br>ing block<br>• Analogue module protection and<br>diagnostics through integrated<br>electronic fuse protection| |---|---|---| |**General technical data**<br>Type<br>CPX-2AA-U-I<br>Voltage output<br>Current output<br>Number of analogue outputs<br>2||| ||Voltage output<br>Current output<br>2|| |Max. actuator supply per module<br>[A]|2.8|| |Fuseprotection|Internal electronic fuse for actuator supply|| |Current consumption from 24 V sensor supply(at full load)<br>[mA]|Max. 150|| |Current consumption from 24 V actuator supply(at full load)<br>[A]|4 ... 10|| |Supplyvoltage for actuators<br>[V DC]|24 ±25%|| |Signal range (parameterisable for each channel with<br>DIL switch or software)|0 ... 10 V DC|0 ... 20 mA<br>4 ... 2 mA| |Resolution<br>[bit]|12|| |Number of units|4096|| |Absolute accuracy<br>[%]|±0.6|| |Linearityerrors (no software scaling)<br>[%]|±0.1|| |Repetition accuracy(at 25°C)<br>[%]|0.05|| |Encoder selection<br>Load resistance for ohmic load<br>[kΩ]<br>Load resistance for capacitive load<br>[μF]<br>Load resistance for inductive load<br>[mH]<br>Short circuit protection for analogue<br>output<br>Short circuit current of analogue<br>output<br>[mA]<br>Open circuit voltage<br>[V DC]<br>Destruction limit against externally<br>applied voltage<br>[V DC]<br>Actuator connection|Min. 1|Max. 0.5| ||Max. 1|–| ||–|Max. 1| ||Yes|–| ||Approx. 20|–| ||–|18| ||15|| ||2 wires|| |Cycle time (module)<br>[ms]|š4|| Subject to change – 2023/10 d **Internet: www.festo.com/catalogue/...** 154 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Output module, analogue ## **General technical data** **==> picture [523 x 563] intentionally omitted <==** **----- Start of picture text -----**<br> Type CPX-2AA-U-I<br>Voltage output Current output<br>Response time For ohmic load [ms] 0.1 0.1<br>For capacitive load [ms] 0.7 –<br>For inductive load [ms] – 0.5<br>Data format 15 bits + prefix, linear scaling<br>12 bits right-justified<br>12 bits left-justified, S7 compatible<br>12 bits left-justified, S5 compatible<br>Cable length [m] Max. 30 (shielded)<br>LED displays Group diagnostics 1<br>Channel diagnostics Yes, via flashing frequency of group diagnostics<br>Diagnostics • Short circuit/overload, actuator supply<br>• Parameterisation error<br>• Value falling below nominal range/full-scale value<br>• Value exceeding nominal range/full-scale value<br>• Wire break<br>Parameterisation • Short circuit monitoring, actuator supply<br>• Short circuit monitoring, analogue output<br>• Behaviour after short circuit, actuator supply<br>• Data format<br>• Lower limit value/full-scale value<br>• Upper limit value/full-scale value<br>• Monitoring value falling below nominal range/full-scale value<br>• Monitoring value exceeding nominal range/full-scale value<br>• Monitoring wire break<br>• Signal range<br>Degree of protection to EN 60529 Depending on connection block<br>Temperature range Operation [°C] –5 ... +50<br>Storage/transport [°C] –20 ... +70<br>Materials PA-reinforced, PC<br>PWIS conformity VDMA24364-B2-L<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block and connection block) W x L x H [mm] 50 x 107 x 50<br>Product weight [g] 49<br>Connection and display components<br>CPX-2AA-U-I<br>[1] Error LED (red; module error)<br>1<br>Combinations of connection blocks and analogue module<br>Connection blocks Part no. Analogue module<br>CPX-2AA-U-I<br>CPX-AB-4-M12X2-5POL 195704 h<br>CPX-AB-4-M12X2-5POL-R 541254 h<br>CPX-AB-8-KL-4POL 195708 h<br>CPX-AB-1-SUB-BU-25POL 525676 h<br>CPX-M-AB-4-M12X2-5POL 549367 h<br>**----- End of picture text -----**<br> 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 155 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Output module, analogue ## **Pin allocation** **==> picture [524 x 575] intentionally omitted <==** **----- Start of picture text -----**<br> Connection block outputs CPX-2AA-U-I<br>CPX-AB-4-M12X2-5POL, CPX-AB-4-M12X2-5POL-R [1)] , CPX-M-AB-4-M12X2-5POL<br>X1.1: 24 VOUT X3.1: 24 VOUT<br>X1.2: Output U0+ X3.2: Output U1+<br>X1.3: 0 VOUT X3.3: 0 VOUT<br>X1.4: Output GND X3.4: Output GND<br>X1.5: FE [2)] X3.5: FE [2)]<br>X2.1: 24 VOUT X4.1: 24 VOUT<br>X2.2: Output I0+ X4.2: Output I1+<br>X2.3: 0 VOUT X4.3: 0 VOUT<br>X2.4: Output GND X4.4: Output GND<br>X2.5: FE [2)] X4.5: FE [2)]<br>CPX-AB-8-KL-4POL<br>X1 .0 .0 X5 X1.0: 24 VOUT X5.0: 24 VOUT<br>.1.2 .1.2 X1.1: 0 VOUT X5.1: 0 VOUT<br>.3 .3 X1.2: Output GND X5.2: Output GND<br>.0 .0 X1.3: FE X5.3: FE<br>X2 .1 .1 X6<br>.2 .2<br>X2.0: n.c. X6.0: n.c.<br>.3 .3<br>.0 .0 X2.1: n.c. X6.1: n.c.<br>X3 .1.2 .1.2 X7 X2.2: Output U0+ X6.2: Output U1+<br>.3 .3 X2.3: FE X6.3: FE<br>.0 .0<br>.1.2 .1.2 X3.0: 24 VOUT X7.0: 24 VOUT<br>X4 .3 .3 X8 X3.1: 0 VOUT X7.1: 0 VOUT<br>X3.2: Output GDN X7.2: Output GND<br>X3.3: FE X7.3: FE<br>X4.0: n.c. X8.0: n.c.<br>X4.1: n.c. X8.1: n.c.<br>X4.2: Output I0+ X8.2: Output I1+<br>X4.3: FE X8.3: FE<br>CPX-AB-1-SUB-BU-25POL<br>1: Output GND 14: Output GND<br>2: Output U0+ 15: Output U1+<br>3: Output GND 16: Output GND<br>4: Output I0+ 17: Output I1+<br>5: n.c. 18: 24 VOUT<br>6: n.c. 19: n.c.<br>7: n.c. 20: 24 VOUT<br>8: n.c. 21: n.c.<br>9: 24 VOUT 22: 0 VOUT<br>10: 24 VOUT 23: 0 VOUT<br>11: 0 VOUT 24: 0 VOUT<br>12: 0 VOUT 25: FE<br>13: Shielding [3)] Housing: FE<br>**----- End of picture text -----**<br> - 1) Speedcon quick lock, additional shielding on metal thread - 2) FE/shield additionally on metal thread - 3) Connect shield to functional earth FE Subject to change – 2023/10 156 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Output module, analogue ## **Ordering data** **==> picture [523 x 579] intentionally omitted <==** **----- Start of picture text -----**<br> Designation Part no. Type<br>Output module, analogue<br>2 analogue current or voltage outputs 526170 CPX-2AA-U-I<br>Connection block<br>Plastic 4x socket, M12, 5-pin 195704 CPX-AB-4-M12X2-5POL<br>4x socket, M12 with quick-lock technology, 5-pin 541254 CPX-AB-4-M12X2-5POL-R<br>Spring-loaded terminal, 32-pin 195708 CPX-AB-8-KL-4POL<br>1x Sub-D socket, 25-pin 525676 CPX-AB-1-SUB-BU-25POL<br>Metal 4x socket, M12, 5-pin 549367 CPX-M-AB-4-M12X2-5POL<br>Distributor<br>Modular system for all types of sensor/actuator distributor – NEDY-...<br>a Internet: nedy<br>Plug<br>M12, 5-pin PG7, for cable @ 4 ... 6 mm 175487 SEA-M12-5GS-PG7<br>Sub-D, 25-pin 527522 SD-SUB-D-ST25<br>Connecting cable<br>Modular system for a choice of connecting cables – NEBU-...<br>a Internet: nebu<br>Cover<br>Cover for CPX-AB-8-KL-4POL (IP65/67) • 8 cable through feeds M9 538219 AK-8KL<br>• 1 cable through feed for multi-pin<br>plug<br>Fittings kit, cover for AK-8KL 538220 VG-K-M9<br>Cover cap for closing off unused M12 connections (10 pieces) 165592 ISK-M12<br>Screening plate<br>Screening plate for connection block 526184 CPX-AB-S-4-M12<br>• CPX-AB-4-M12X2-5POL<br>• CPX-AB-4-M12X2-5POL-R<br>User documentation<br>User documentation German 526415 P.BE-CPX-AX-DE<br>English 526416 P.BE-CPX-AX-EN<br>Spanish 526417 P.BE-CPX-AX-ES<br>French 526418 P.BE-CPX-AX-FR<br>Italian 526419 P.BE-CPX-AX-IT<br>**----- End of picture text -----**<br> 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 157 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – PROFIsafe shut-off module ## **Area of application** ## **Function** - The PROFIsafe shut-off module inter• Output module for 24 V DC supply rupts the contact rails of the interlinkvoltage ing block for valves and outputs. The • Shut-off module for supply voltage supply voltage for valves can be for valves switched by the module within the • Can only be used with PROFINET or CPX-P terminal and via a connection PROFIBUS bus nodes block to two consuming devices. • The shut-off module is supplied Actuation takes place via the bus node with voltage for the electronics and (PROFINET) of the CPX-P terminal. the outputs by the interlinking block **==> picture [256 x 115] intentionally omitted <==** - The outputs are supplied from the power supply for valves (VValves) ## **General technical data** **==> picture [524 x 416] intentionally omitted <==** **----- Start of picture text -----**<br> Type CPX-FVDA-P2<br>Number of outputs 2<br>Note on outputs 1 internal channel for switching off the supply voltage for valves<br>2 external outputs<br>Max. address capacity Inputs [byte] 6<br>Outputs [byte] 6<br>Maximum cable length [m] 200<br>Max. power supply Per module [A] 5<br>Per channel [A] 1.5<br>Fuse protection (short circuit) Internal electronic fuse per channel<br>Current consumption of module [mA] Typically 65 (power supply for valves)<br>[mA] Typically 25 (power supply for electronics)<br>Operating voltage Nominal value [V DC] 24<br>Permissible range [V DC] 20.4 ... 28.8<br>Voltage drop per channel [V] 0.6<br>Residual ripple [Vss] 2 within voltage range<br>Load capacity to FE [nF] 400<br>Max. response time to shut-off command [ms] 23<br>Galvanic isolation Channel – channel No<br>Channel – internal bus Yes, with intermediate supply<br>Switching logic Outputs P-M switching<br>Safety integrity level Safe switch-off, SIL3<br>Performance Level Safe switch-off/category 3, Performance Level e<br>Failure rate per hour (PFH) 1.0x 10 [-9]<br>Certificate issuing authority 01/205/50294/13<br>LED displays Group diagnostics 1<br>Channel diagnostics 3<br>Channel status 3<br>Failsafe protocol active 1<br>Diagnostics • Short circuit/overload per channel<br>• Undervoltage of valves<br>• Cross circuit<br>• Wire break per channel<br>Parameterisation • Monitoring of wire break per channel<br>• Diagnostic behaviour<br>Degree of protection to EN 60529 Depending on connection block<br>Grid dimension [mm] 50<br>Dimensions (including interlinking block and connection block) W x L x H [mm] 50 x 107 x 55<br>Product weight [g] 50<br>**----- End of picture text -----**<br> Subject to change – 2023/10 158 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – PROFIsafe shut-off module **==> picture [523 x 170] intentionally omitted <==** **----- Start of picture text -----**<br> Materials<br>Housing PA-reinforced, PC<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Operating and environmental conditions<br>Ambient temperature [°C] –5 ... +50<br>Storage temperature [°C] –20 ... +70<br>CE marking (see declaration of conformity) [1)] To EU Machinery Directive<br>To EU EMC Directive<br>To EU RoHS Directive<br>UKCA marking (see declaration of conformity) [1)] To UK instructions for machines<br>To UK instructions for EMC<br>To UK RoHS instructions<br>Certification c UL us - Recognized (OL)<br>**----- End of picture text -----**<br> - 1) More information: www.festo.com/catalogue/... d Support/Downloads. |**Connection and display components**|**Connection and display components**|**Connection and display components**|**Connection and display components**|**Connection and display components**| |---|---|---|---|---| |CPX-FVDA-P2||||| ||||4<br>~~3~~<br>[1] Status LEDs (yellow):<br>0: Supply voltage for valves<br>1: X1<br>2: X2<br>[2] Channel-related error LEDs (red)<br>[3] Fail-safe protocol active (green)<br>[4] Error LED (red, module error)|| |||||4| |||||| |||||| |||~~1~~<br>~~2~~||| ## **Combinations of bus nodes/control blocks and PROFIsafe shut-off module** |**Combinations of bus nodes/control blocks and PROFIsafe shut-off module**|**Combinations of bus nodes/control blocks and PROFIsafe shut-off module**|**Combinations of bus nodes/control blocks and PROFIsafe shut-off module**| |---|---|---| |Bus node/control block<br>CPX-FB13|Part no.<br>**195740**|PROFIsafe shut-off module| |||CPX-FVDA-P2<br>h| |CPX-FB43|**8110369**|h| |CPX-M-FB44|**8110370**|h| |CPX-M-FB45|**8110371**|h| ## - **Note** H- The PROFIsafe shut-off module CPX-FVDA-P2 can only be connected as of software release 21 or release 30 (in the case of CPX-FB13). 2023/10 – Subject to change 159 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – PROFIsafe shut-off module **==> picture [524 x 484] intentionally omitted <==** **----- Start of picture text -----**<br> Combinations of connection blocks and PROFIsafe shut-off module<br>Connection blocks Part no. PROFIsafe shut-off module<br>CPX-FVDA-P2<br>CPX-M-AB-4-M12X2-5POL 549367 h<br>CPX-AB-8-KL-4POL 195708 h<br>Pin allocation<br>Connection block outputs CPX-FVDA-P2<br>CPX-M-AB-4-M12X2-5POL<br>X1.1: 0 VOUT 1 (cannot be switched off) X3.1: n.c.<br>X1.2: 24 VOUT 1 (cannot be switched off) X3.2: n.c.<br>X1.3: 0 VOUT 1 (can be switched off via fieldbus) X3.3: n.c.<br>X1.4: 24 VOUT 1 (can be switched off via fieldbus) X3.4: n.c.<br>X1.5: FE X3.5: FE<br>X2.1: 0 VOUT 2 (cannot be switched off) X4.1: n.c.<br>X2.2: 24 VOUT 2 (cannot be switched off) X4.2: n.c.<br>X2.3: 0 VOUT 2 (can be switched off via fieldbus) X4.3: n.c.<br>X2.4: 24 VOUT 2 (can be switched off via fieldbus) X4.4: n.c.<br>X2.5: FE X4.5: FE<br>CPX-AB-8-KL-4POL<br>X1 .0 .0 X5 X1.0: 0 VOUT 1 (cannot be switched off) X5.0: n.c.<br>.1.2 .1.2 X1.1: 0 VOUT 1 (can be switched off via fieldbus) X5.1: n.c.<br>.3 .3 X1.2: 24 VOUT 1 (can be switched off via fieldbus) X5.2: n.c.<br>.0 .0 X1.3: FE X5.3: n.c.<br>X2 .1 .1 X6<br>.2 .2<br>X2.0: n.c. X6.0: n.c.<br>.3 .3<br>.0 .0 X2.1: n.c. X6.1: n.c.<br>X3 .1.2 .1.2 X7 X2.2: 24 VOUT 1 (cannot be switched off) X6.2: n.c.<br>.3 .3 X2.3: FE X6.3: n.c.<br>.0 .0<br>.1.2 .1.2 X3.0: 0 VOUT 2 (cannot be switched off) X7.0: n.c.<br>X4 .3 .3 X8 X3.1: 0 VOUT 2 (can be switched off via fieldbus) X7.1: n.c.<br>X3.2: 24 VOUT 2 (can be switched off via fieldbus) X7.2: n.c.<br>X3.3: FE X7.3: n.c.<br>X4.0: n.c. X8.0: n.c.<br>X4.1: n.c. X8.1: n.c.<br>X4.2: 24 VOUT 2 (cannot be switched off) X8.2: n.c.<br>X4.3: FE X8.3: n.c.<br>**----- End of picture text -----**<br> Subject to change – 2023/10 160 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – PROFIsafe shut-off module |Data sheet – PROFIsafe shut-off module|Data sheet – PROFIsafe shut-off module|Data sheet – PROFIsafe shut-off module| |---|---|---| |**Combinations of interlinking blocks and PROFIsafe shut-off module**<br>Interlinking blocks<br>Part no.<br>PROFIsafe shut-off module<br>CPX-FVDA-P2<br>CPX-M-GE-EV-S-7/8-5POL<br>**550208**<br>–||| |||CPX-FVDA-P2<br>–| |CPX-M-GE-EV-S-7/8-5POL-VL|**8022165**|–| |CPX-M-GE-EV|**550206**|–| |CPX-M-GE-EV-FVO|**567806**|h| |CPX-M-GE-EV-Z-7/8-5POL|**550210**|–| |CPX-M-GE-EV-Z-7/8-5POL-VL|**8022158**|–| |||| ## **General technical data** **==> picture [523 x 134] intentionally omitted <==** **----- Start of picture text -----**<br> Type CPX-M-GE-EV-FVO<br>Nominal operating voltage [V DC] 24<br>Acceptable current load (per contact/contact rail) [A] 16<br>Degree of protection to EN 60529 Depending on connection block<br>Ambient temperature [°C] –5 ... +50<br>Materials Die-cast aluminium<br>Note on materials RoHS-compliant<br>PWIS conformity VDMA24364-B2-L<br>Type of mounting Angled fitting<br>Grid dimension [mm] 50<br>Dimensions W x L x H [mm] 50 x 107 x 35<br>Product weight [g] 170<br>**----- End of picture text -----**<br> ## **Pin allocation** **==> picture [523 x 156] intentionally omitted <==** **----- Start of picture text -----**<br> Circuitry Pin Allocation<br>– –<br>– –<br>– –<br>– –<br>**----- End of picture text -----**<br> 2023/10 – Subject to change 161 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – PROFIsafe shut-off module ## **Ordering data** **==> picture [524 x 516] intentionally omitted <==** **----- Start of picture text -----**<br> Description Part no. Type<br>PROFIsafe shut-off module<br>Electronics module PROFINET, PROFIBUS 1971599 CPX-FVDA-P2<br>(can only be used with CPX-M-GE-EV-FVO)<br>Metal interlinking block (exclusively for CPX-FVDA-P2) 567806 CPX-M-GE-EV-FVO<br>Connection block<br>Plastic Spring-loaded terminal, 32-pin 195708 CPX-AB-8-KL-4POL<br>Metal 4x socket M12, 5-pin 549367 CPX-M-AB-4-M12X2-5POL<br>Distributor<br>1x plug M12, 4-pin 2x socket M12, 5-pin 8005310 NEDY-L2R1-V1-M12G5-N-M12G4<br>Modular system for all types of sensor/actuator distributor – NEDY-...<br>a Internet: nedy<br>Plug<br>M12, 4-pin PG7, for cable @ 4 ... 6 mm 18666 SEA-GS-7<br>PG7, for cable @ 2.5 ... 2.9 mm 192008 SEA-4GS-7-2.5<br>PG9, for cable @ 6 ... 8 mm 18778 SEA-GS-9<br>PG11, for 2x cable @ 3 ... 5 mm 18779 SEA-GS-11-DUO<br>M12, 5-pin PG7, for cable @ 4 ... 6 mm 175487 SEA-M12-5GS-PG7<br>PG11, for 2x cable @ 2.5 ... 5 mm 192010 SEA-5GS-11-DUO<br>Connecting cable<br>Modular system for a choice of connecting cables – NEBU-...<br>a Internet: nebu<br>User documentation<br>User documentation for PROFIsafe shut-off module German 8022606 CPX-FVDA-P2-DE<br>English 8022607 CPX-FVDA-P2-EN<br>Spanish 8022608 CPX-FVDA-P2-ES<br>French 8022609 CPX-FVDA-P2-FR<br>Italian 8022610 CPX-FVDA-P2-IT<br>Chinese 8022611 CPX-FVDA-P2-ZH<br>**----- End of picture text -----**<br> Subject to change – 2023/10 162 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – Interlinking block with system supply ## **Function** ## **Area of application** Interlinking blocks ensure the electri• 24 V DC supply voltage for cal supply of all other CPX-P modules. electronics of the CPX-P terminal They have contact rails from which the • 24 V DC supply voltage for inputs other CPX-P components on the inter• 24 V DC supply voltage for valves linking modules are supplied with • 24 V DC supply voltage for outputs current. Internal division of the power supply makes it possible to switch off specific areas of the sensors and actuators individually. ## **General technical data** |**General technical data**||| |---|---|---| |Nominal operatingvoltage|[V DC]|24| |Degree ofprotection to EN 60529||Dependingon connection block| |Ambient temperature|[°C]|–5 ... +50| |Grid dimension|[mm]|50| |Dimensions W x L x H|[mm]|50 x 107 x 35| |Electrical connection||7/8", 5-pin| |Power supply|Sensors and electronics<br>[A]|Max. 8| ||Valves and outputs<br>[A]|Max. 8| |Materials||Die-cast aluminium| |Note on materials||RoHS-compliant| |PWIS conformity||VDMA24364-B2-L| |Product weight|[g]|187| **Pin allocation** Circuitry Pin Allocation ~~|~~ **Round plug, 5-pin** OV ~~CT~~ **7/8"** ate ~~a~~ 1 0 V valves and outputs 24V vas a ~~a~~ 2 0 V electronics and sensors 3 FE 4 24 V DC supply voltage for electronics and sensors 5 24 V DC load voltage supply for valves and outputs 2AV oupa ~~5 1 ns~~ 2023/10 – Subject to change 163 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Interlinking block with system supply ## **Ordering data** **==> picture [524 x 216] intentionally omitted <==** **----- Start of picture text -----**<br> Designation Part no. Type<br>Interlinking block with system supply<br>7/8" connection, metal 5-pin – 550208 CPX-M-GE-EV-S-7/8-5POL<br>interlinking block<br>For ATEX environment 8022165 CPX-M-GE-EV-S-7/8-5POL-VL<br>Connection sockets 7/8"<br>Power supply socket 5-pin 543107 NECU-G78G5-C2<br>Angled socket, 5-pin Open cable end, 5-pin 2 m 573855 NEBU-G78W5-K-2-N-LE5<br>Mounting accessories<br>Screws for mounting the bus node/connection block on an Bus node/plastic connection block 550219 CPX-M-M3x22-4x<br>interlinking block Bus node/metal connection block 550216 CPX-M-M3x22-S-4x<br>**----- End of picture text -----**<br> Subject to change – 2023/10 164 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – Interlinking block without power supply ## **Function** ## **Area of application** Interlinking blocks ensure the electri• All voltages are fed through to the cal supply of all other CPX-P modules. next module via the interlinking They have contact rails from which the blocks without supply. other CPX-P components on the inter• The connected electronics module linking modules are supplied with for inputs/outputs or bus node taps current. off the required voltage. Internal division of the power supply makes it possible to switch off specific areas of the sensors and actuators individually. |**General technical data**|**General technical data**||||||| |---|---|---|---|---|---|---|---| ||||||||| |Electrical connection||||||–|| |Nominal operatingvoltage|||||[V DC]|24|| |Acceptable current load (per contact/contact rail)|||||[A]|16|| |Degree ofprotection to EN 60529||||||Dependingon connection block|| |Ambient temperature|||||[°C]|–5 ... +50|| |Materials||||||Aluminium|| |Note on materials||||||RoHS-compliant|| |PWIS conformity||||||VDMA24364-B2-L|| |Grid dimension|||||[mm]|50|| |Dimensions W x L x H|||||[mm]|50 x 107 x 35|50 x 107 x 35| |Product weight|||||[g]|169|| ||||||||| |**Pin allocation**|||||||| |Circuitry||||||Pin|Allocation| |||||||–|–| |||||||–|–| |||24VValves||||–<br>~~a~~|–| |||||||–|–| 2023/10 – Subject to change 165 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Interlinking block without power supply **==> picture [524 x 142] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Interlinking block without power supply<br>Metal interlinking block 550206 CPX-M-GE-EV<br>Mounting accessories<br>Screws for mounting the bus node/connection block on an Bus node/plastic connection block 550219 CPX-M-M3x22-4x<br>interlinking block Bus node/metal connection block 550216 CPX-M-M3x22-S-4x<br>**----- End of picture text -----**<br> Subject to change – 2023/10 166 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – Interlinking block with additional supply for outputs ## **Function** ## **Area of application** Interlinking blocks ensure the electri• 24 V DC supply voltage for outputs cal supply of all other CPX-P modules. They have contact rails from which the other CPX-P components on the interlinking modules are supplied with current. Internal division of the power supply makes it possible to switch off specific areas of the sensors and actuators individually. ## **General technical data** |**General technical data**|| |---|---| |Nominal operatingvoltage<br>[V DC]|24| |Degree ofprotection to EN 60529|Dependingon connection block| |Ambient temperature<br>[°C]|–5 ... +50| |Grid dimension<br>[mm]|50| |Dimensions W x L x H<br>[mm]|50 x 107 x 35| |Electrical connection|7/8", 5-pin| |Power supply<br>Outputs<br>[A]|Max. 8| |Materials|Die-cast aluminium| |Note on materials|RoHS-compliant| |PWIS conformity|VDMA24364-B2-L| |Product weight<br>[g]|187| ## **Pin allocation – Metal interlinking blocks** Circuitry Pin Allocation ~~Sees~~ **Round plug, 5-pin 7/8"** ~~oF _————~~ 1 0 V outputs ~~mesa a~~ TT) 2 ~~g —~~ 2 n.c. 3 FE 4 n.c. Output ro} O ~~rid~~ wv ae ~~a~~ 5 24 V DC load voltage supply for outputs 2023/10 – Subject to change 167 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet – Interlinking block with additional supply for outputs ## **Ordering data** **==> picture [524 x 216] intentionally omitted <==** **----- Start of picture text -----**<br> Designation Part no. Type<br>Interlinking block with additional supply for outputs<br>7/8" connection, metal 5-pin – 550210 CPX-M-GE-EV-Z-7/8-5POL<br>interlinking block<br>For ATEX environment 8022158 CPX-M-GE-EV-Z-7/8-5POL-VL<br>Connection sockets 7/8"<br>Power supply socket 5-pin 543107 NECU-G78G5-C2<br>Angled socket, 5-pin Open cable end, 5-pin 2 m 573855 NEBU-G78W5-K-2-N-LE5<br>Mounting accessories<br>Screws for mounting the bus node/connection block on an Bus node/plastic connection block 550219 CPX-M-M3x22-4x<br>interlinking block Bus node/metal connection block 550216 CPX-M-M3x22-S-4x<br>**----- End of picture text -----**<br> Subject to change – 2023/10 168 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – Pneumatic interface for valve terminal MPA-S ## **Function** The pneumatic interface VMPA-FB establishes the electromechanical connection between the CPX-P terminal and the valve terminal MPA-S. The signals from the bus node are forwarded to the control electronics in the electrical modules of the valve terminal MPA-S via the integrated CPX-P bus. The bus signal for activating the solenoid coils is converted in the electronics module for max. 8 coils. From a technical point of view, the individual MPA pneumatic modules each represent a separate electrical module with digital outputs. Galvanically isolated valves can be supplied with power via the interlinking block CPX-GE-EV-V. ## **Area of application** - Interface to the valve terminal MPA-S - Max. 128 solenoid coils - Characteristics of the electronics module of the valve terminal MPA-S can be parameterised; for example, status of the solenoid coils in the event of fieldbus communication being interrupted (fail-safe), individual channel diagnostics can be activated, condition monitoring can be activated individually for each valve - The pneumatic interface receives the voltage for the electronics and the supply voltage for the valves from the left interlinking block and feeds them through to the electronics modules of the valve terminal MPA-S - Electronics modules of the valve terminal MPA-S: - Undervoltage of valves - Short circuit of valves - Open load of valves - Counter preset reached in condition monitoring ||**General technical data**|||||| |---|---|---|---|---|---|---| ||Type||||VMPA-FB-EPL-G|VMPA-FB-EPL-E| |||||||| ||Valve terminal design||||Modular, valve sizes can be mixed|| ||Maximum number of valvepositions||||64|| ||Maximum number ofpressure zones||||17|| ||Signal status indication||||LED|| ||Pilot air supply||||Internal|External| ||Operating pressure|||[MPa]|0.3 ... 0.8|–0.09 ... 1| |||||[bar]|3 ... 8|–0.9 ... 10| ||Pilot pressure|||[MPa]|0.3 ... 0.8|0.3 ... 0.8| |||||[bar]|3 ... 8|3 ... 8| ||Product weight|||[g]|320|| ||Degree of protection||||IP67|| |||||||| |**Technical data – Electrics**<br>Nominal operatingvoltage<br>[V DC]<br>24<br>Permissible voltage fluctuations<br>[%]<br>±25<br>~~—————~~||||||| |**Materials**<br>Note on materials<br>RoHS-compliant<br>LABS (PWIS) conformity<br>VDMA24364-B1/B2-L<br>~~—————~~||||||| 2023/10 – Subject to change 169 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P ## Data sheet – Pneumatic interface for valve terminal MPA-S ## **Overview – Pneumatic interface VMPA-FB** **==> picture [524 x 453] intentionally omitted <==** **----- Start of picture text -----**<br> |||||||| |---|---|---|---|---|---|---| |4| |3| |||an|Sez SSS| |S|See| |2| |1|WI NRAP| |5| |SSSs,|Qe|||Oe|@_|[1] Pneumatic interface VMPA‐FB| |[2] Inscription label| |>|>|oF)|xe,| |[3] Flat plate silencer| |oO|[4] Exhaust plate for ducted exhaust| |air| |<2.| |[5] Fittings| |Ordering data| |Designation|Part no.|Type| |||Pneumatic interface| |Ducted exhaust air|Internal pilot air|552286|VMPA-FB-EPLM-G| |External pilot air|552285|VMPA-FB-EPLM-E| |Flat plate silencer|Internal pilot air|552288|VMPA-FB-EPLM-GU| |SSeeeCT|Exhaust plate|External pilot air|eee|552287|VMPA-FB-EPLM-EU|eee| |For ducted exhaust air, with push-in connector|For tubing O.D. 10 mm|533375|VMPA-AP| |For tubing O.D. 3/8"|541629|VMPA-AP-3/8| |SSne|Flat plate silencer|ee|ee|533374|ee|VMPA-APU| **----- End of picture text -----**<br> Subject to change – 2023/10 170 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet **==> picture [523 x 480] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions – Metal interlinking block Download CAD data a www.festo.com<br>With bus nodes and connection blocks<br>[1] Left-hand end plate [5] Connection block [8] Connection block [10] Mounting bracket for wall<br>[2] Bus node CPX-AB-8-KL-4POL CPX-P-AB-4XM12-4POL mounting<br>[3] Connection block [6] Connection block [9] Right-hand end plate [11] Hole for self-tapping screw<br>CPX-AB-8-M8-3POL CPX-AB-1-SUB-BU-25POL M2.5<br>[4] Connection block [7] Connection block<br>CPX-AB-4-M12X2-5POL CPX-P-AB-4-2XKL-8POL<br>Type B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12<br>CPX-P 124.9 124.6 118.9 108.1 78 66.3 65 19.3 20 7.9 6.6 4.4<br>Type H1 H2 H3 H4 H5 H6 H7<br>CPX-P 116 109 106.2 69.2 55.1 46.6 10.8<br>Type L1 L2 L3 L4 L5 L6 L7 L8 L9 L10<br>CPX-P nx50.1 150.3 125.3 50.1 30.4 6.8 4.5 4 1.5 1<br>**----- End of picture text -----**<br> 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 171 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Data sheet **==> picture [522 x 560] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions Download CAD data a www.festo.com<br>With bus node and valve terminal MPA-S<br>[1] Solenoid valve MPA1 [6] H-rail [11] Earthing screw n Number of sub-bases in a grid<br>[2] Solenoid valve MPA2 [7] H-rail mounting [12] Electrical supply plate of 4 MPA1 or 2 MPA2 valves<br>[3] Manual override [8] Mounting holes [13] Pressure sensor m Number of CPX-P modules<br>[4] Supply/exhaust ports [9] Pneumatic interface VMPA‐FB [14] Proportional-pressure regulator<br>[5] Working ports [10] CPX-P module<br>Type B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14<br>CPX-P 131.4 107.3 78 66.3 65 33.5 23.5 19.3 18 11 6.6 4.4 7.5 20<br>Type H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 H12 H13 H14 H15<br>CPX-P 62 60.5 56 48 44.3 23.9 23.1 22.6 21.8 20.3 10.8 9.8 8.8 8.7 46.6<br>Type L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12<br>CPX-P m x 50.1 n x 42 51.2 42 32 30.4 34.7 25.7 16.7 30 21 16<br>Type L13 L14 L15 L16 L17 L18 L19 L20 L21 L22 L23 L24<br>CPX-P 12 20 18 10.5 7.7 9 23.7 13.5 14.5 25.9 1.5 1<br>**----- End of picture text -----**<br> Subject to change – 2023/10 172 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Accessories ## **Ordering data** **==> picture [523 x 483] intentionally omitted <==** **----- Start of picture text -----**<br> Designation Part no. Type<br>Plugs<br>Sub-D socket, 9-pin For DeviceNet 532219 FBS-SUB-9-BU-2x5POL-B<br>Sub-D plug, 9-pin For PROFIBUS DP 532216 FBS-SUB-9-GS-DP-B<br>Sub-D plug, angled For PROFIBUS DP 533780 FBS-SUB-9-WS-PB-K<br>Bus connection, Sub-D plug, 9-pin B-coded For PROFIBUS DP 533118 FBA-2-M12-5POL-RK<br>adapter to M12 plug/socket, Sub-D socket, 9-pin Micro style For DeviceNet 525632 FBA-2-M12-5POL<br>5-pin<br>M12 socket, 5-pin Screw terminal For FBA-2-M12-5POL 18324 FBSD-GD-9-5POL<br>Screw terminal For FBA-2-M12-5POL-RK and 1067905 NECU-M-B12G5-C2-PB<br>CPX-AB-2-M12-RK-DP<br>Plug M8, 3-pin Solderable For NEDY-L2R1-V1-M8G3-N-M8G4 18696 SEA-GS-M8<br>Screw-in For NEDY-L2R1-V1-M8G3-N-M8G4 192009 SEA-3GS-M8-S<br>Plug M12, 4-pin Spring-loaded terminal For cable @ 4 ... 8 mm 575719 NECU-M-S-A12G4-IS [1)]<br>Screw terminal D-coded For Ethernet 543109 NECU-M-S-D12G4-C2-ET<br>For cable @ 2.5 ... 2.9 mm 570955 NECU-S-M12G4-P1-Q6-IS [1)]<br>192008 SEA-4GS-7-2.5<br>For cable @ 2x3 mm or 2x5 mm 570956 NECU-S-M12G4-D-IS [1)]<br>For 2x cable @ 3 ... 5 mm 18779 SEA-GS-11-DUO<br>For cable @ 4 ... 6 mm 570953 NECU-S-M12G4-P1-IS [1)]<br>18666 SEA-GS-7<br>For cable @ 6 ... 8 mm 570954 NECU-S-M12G4-P2-IS [1)]<br>18778 SEA-GS-9<br>Plug M12, 5-pin Screw terminal For 2x cable @ 2.5 ... 5 mm 192010 SEA-5GS-11-DUO<br>For cable @ 4 ... 6 mm 175487 SEA-M12-5GS-PG7<br>For FBA-2-M12-5POL 175380 FBS-M12-5GS-PG9<br>For FBA-2-M12-5POL-RK and 1066354 NECU-M-S-B12G5-C2-PB<br>CPX-AB-2-M12-RK-DP<br>Connection block, adapter to Sub-D socket, 9-pin – For DeviceNet 571052 CPX-AB-1-7/8-DN<br>5-pin 7/8" plug<br>Connection block, adapter to Sub-D plug, 9-pin B-coded For PROFIBUS DP 541519 CPX-AB-2-M12-RK-DP<br>M12 plug/socket<br>Open style bus connection for 5-pin terminal strip For DeviceNet 525634 FBA-1-SL-5POL<br>5-pin terminal strip For open style 525635 FBSD-KL-2x5POL<br>connection<br>**----- End of picture text -----**<br> 1) Component preferred for operation in intrinsically safe circuits. 2023/10 – Subject to change 173 d **Internet: www.festo.com/catalogue/...** Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Accessories **==> picture [524 x 365] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Connectors<br>RJ45 plug 534494 FBS-RJ45-8-GS<br>Socket, 8-pin Spring-loaded terminal Black 565712 NECU-L3G8-C1<br>Blue 565711 NECU-L3G8-C1-IS [1)]<br>Screw terminal Black 565710 NECU-L3G8-C2<br>Blue 565709 NECU-L3G8-C2-IS [1)]<br>Sub-D plug, 25-pin 527522 SD-SUB-D-ST25<br>Connecting cable<br>Modular system for all types of sensor/actuator distributor – NEDY-...<br>a Internet: nedy<br>Modular system for a choice of connecting cables – NEBU-...<br>a Internet: nebu<br>Push-in T-connector 1x plug M8, 4-pin 2x socket M8, 3-pin 8005312 NEDY-L2R1-V1-M8G3-N-M8G4<br>1x plug M12, 4-pin 2x socket M8, 3-pin 8005311 NEDY-L2R1-V1-M8G3-N-M12G4<br>2x socket M12, 4-pin 562248 NEDU-M12D4-M12T4-IS [1)]<br>2x socket, M12, 5-pin 8005310 NEDY-L2R1-V1-M12G5-N-M12G4<br>1x socket M8, 3-pin 1x plug M8, 3-pin 0.5 m 541346 NEBU-M8G3-K-0.5-M8G3<br>1.0 m 541347 NEBU-M8G3-K-1-M8G3<br>2.5 m 541348 NEBU-M8G3-K-2.5-M8G3<br>5.0 m 541349 NEBU-M8G3-K-5-M8G3<br>Connecting cable M12-M12 5-pin Straight plug/ 1.5 m 529044 KV-M12-M12-1.5<br>straight socket 3.5 m 530901 KV-M12-M12-3.5<br>**----- End of picture text -----**<br> 1) Component preferred for operation in intrinsically safe circuits. Subject to change – 2023/10 d **Internet: www.festo.com/catalogue/...** 174 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Accessories **==> picture [523 x 495] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Connectors and accessories – Power supply<br>Power supply socket, straight 7/8" connection, 5-pin 543107 NECU-G78G5-C2<br>7/8" power supply socket, Open cable end, 5-pin 2 m 573855 NEBU-G78W5-K-2-N-LE5<br>5-pin, angled socket<br>Hood<br>Mounting rail for attaching the hood 1000 mm 572256 CAFC-X1-S<br>Mounting kit for CPX hood 572257 CAFC-X1-BE<br>Hood section for CPX-P terminal including mounting attachments for connecting 200 mm 572258 CAFC-X1-GAL-200<br>several hood sections in series<br>300 mm 572259 CAFC-X1-GAL-300<br>Screws<br>Screws for mounting the bus node/connection block on an Bus node/plastic connection block 550219 CPX-M-M3x22-4x<br>interlinking block Bus node/metal connection block 550216 CPX-M-M3x22-S-4x<br>Mounting<br>Attachment for wall mounting (for long valve terminals, 2 Version for metal interlinking plates 550217 CPX-M-BG-RW-2x<br>mounting brackets and 4 screws)<br>Mounting for H-rail 526032 CPX-CPA-BG-NRH<br>Function blocks<br>Terminating resistor, M12, B-coded for PROFIBUS 1072128 CACR-S-B12G5-220-PB<br>Adapter M12, 5-pin to mini USB socket, and controller software 547432 NEFC-M12G5-0.3-U1G5<br>**----- End of picture text -----**<br> 2023/10 – Subject to change d **Internet: www.festo.com/catalogue/...** 175 Terminal CPX-P **==> picture [596 x 40] intentionally omitted <==** ## Accessories **==> picture [524 x 458] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering data<br>Designation Part no. Type<br>Covers and attachments<br>Cover for CPX-AB-8-KL-4POL (IP65/67) 8 cable through feeds M9 538219 AK-8KL<br>1 cable through feed for multi-pin plug<br>Fittings kit for cover AK-8KL 538220 VG-K-M9<br>Screening plate for connection block 526184 CPX-AB-S-4-M12<br>• CPX-AB-4-M12X2-5POL<br>• CPX-AB-4-M12X2-5POL-R<br>Inspection cover, transparent 533334 AK-SUB-9/15-B<br>Transparent cover for DIL switch 548757 CPX-AK-P<br>Cover for RJ45 connection 534496 AK-RJ45<br>Cover cap for closing off unused connections (10 pieces) For M8 connections 177672 ISK-M8<br>For M12 connections 165592 ISK-M12<br>Coding element (96 pieces of each) For NECU-L3G8 565713 CPX-P-KDS-AB-2XKL<br>Insulating plate for safe separation of intrinsically safe and non-intrinsically safe areas of the CPX 565708 CPX-P-AB-IP [1)]<br>terminal<br>Inscription labels<br>Inscription label holder for connection block 536593 CPX-ST-1<br>Inscription labels 6x10 mm, 64 pieces, in frame 18576 IBS-6x10<br>**----- End of picture text -----**<br> 1) Component preferred for operation in intrinsically safe circuits. Subject to change – 2023/10 176 d **Internet: www.festo.com/catalogue/...**
Updated at June 9, 2026
Festo is a globally recognized leader in industrial automation, renowned for its innovative pneumatic and electrical control and drive technologies. As an engineering-driven company, Festo provides robust, high-quality components designed to optimize both factory and process automation systems across a wide range of demanding industries. A cornerstone of their automation expertise is a comprehensive portfolio of precision sensory technology. The core of this offering is focused on advanced pressure sensors and transducers. These vital components are engineered to deliver highly accurate fluid and gas measurements, ensuring reliable monitoring, system safety, and optimal efficiency in complex industrial environments. Complementing their fluid control solutions, Festo also manufactures a dependable selection of proximity sensors and proximity switches. Built for durability and precise object detection, these sensors provide the essential positional feedback required to maintain seamless and automated operational workflows.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →