526413
P.BE-CPX-FB14-IT DESCRIPTION
- Manufacturer: FESTO
- Product type: Controller Accessories
- SVHC: No SVHC (25-Jun-2020)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 111.18 € |
| Current stock | 10+ |
| Lead time | 30 days |
# CPI installation system
## CPI installation system
Key features
## ee Innovative es Sturdy || Versatile
- A number of CP interfaces can be combined under one fieldbus node
- Complete concept for decentralised machine and system structure; centralised and decentralised installation can be combined with the CPX terminal
- Electrical accessories to IP65
- Proven valve terminals CPV (compact), MPA (sturdy, modular), CPV-SC (small, compact) and CPA (modular manifold sub-bases)
- Four CP strings up to 10 m in length (radius) facilitate optimum decentralisation
- Max. 32 inputs and 32 outputs/ valves per string
- Electrical input and output modules in metal housing or compact in encapsulated plastic housing
- Decentralised pneumatics and sensors for fast processes
- Available valves:
- Centralised electrics for fieldbus and common power supply
- and common power supply • Sturdy connection technology M12,
- • Flexible configuration of the alternatively M8 individual CP strings • IP20 modules for control cabinet
- Valve terminal type 32 MPA, flow rate max. 700 l/min
- IP20 modules for control cabinet installation with spring-loaded terminals or screw terminals
- Valve terminal type 10 CPV, flow rate max. 1,600 l/min
- Selectable valve terminal sizes for optimum pneumatic control loop systems
- Valve terminal type 80 CPV-SC, flow rate max. 170 l/min
- Performance data as for the CP system with the addition of the comprehensive diagnostic capabilities of the CPX terminal
- Valve terminal type 12 CPA, flow rate max. 650 l/min
- Input modules with 8 … 32 inputs and output modules with 4 … 8 outputs, each with or without additional power supply
## Reliable
- Sturdy modules and accessories
- Ready to install system including CP cable (hybrid cable for data and power)
- Polarity-safe and short circuit proof connections
- Valves with separate load voltage supply
- All modules equipped with local diagnostics and status LEDs
- Diagnostics of each CP string via controller/fieldbus
- Intelligent system (save button)
- ”learns” current configuration
- Easy replacement of modules at any time
- Universal electrical outputs
Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
2
## CPI installation system
Key features
## CPI installation system
The CPI system is capable of meeting two completely different requirements and resolves the conflict between extensive decentralised modularisation and electrical installation.
High-speed machines require short cycle times and short pneumatic tubing. The valves must be mounted close to the cylinders. The CPI system was developed to meet these requirements without having to wire each valve individually.
Scope of features:
The system integrates the modular valve terminals CPV, the manifold subbase valve terminal CPA and various input/output modules in a single installation concept.
- Max. 4 installation strings per CP interface
- Max. 10 metre line length per string (radius)
- Max. 4 CP modules per string
- Max. 32 inputs and max. 32 outputs per string
All CP valve terminals and CP modules Max. 32 inputs and max. 32 outare connected using a ready to install puts per string CP cable, and are attached to the CP interface. Four modules, for example The number of CP modules that can be one CPV valve terminal and one to connected and the number of inputs/ three CP input modules, make up an outputs is dependent on the type of CP installation string that ends at the CP interface.
module and CP interface. The maximum configuration (4 modules per string, 32 inputs/outputs) is only possible in combination with the CPX terminal and CP modules with CPI functionality.
The CP interface is the central connection point for the valve power supply and the sensor supply. The power supply for the sensors connected to the input modules is separate from the load voltage of the valves.
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
3
## CPI installation system
Key features
Node types: Fieldbus/control block Fieldbus CPX with CP interface Type 03/04 with CP interface CPX-… CP-FB-…
CP fieldbus node Valve terminal with CP string extension CP-E CPV, CPA-SC, CPV-SC, CDVI-DN, MPA
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
4
## CPI installation system
Ordering system
|Configurator|||Online via:�www.festo.com|
|---|---|---|---|
|Selecting a CPI system using the|Components from the CPI system|Ordering system for type 55E||
|online catalogue is quick and easy|series, type CTEC, are ordered using|�Internet:ctec||
|thanks to the convenient configurator|the order code.|||
|provided. This makes it much easier||||
|to find the right product.||||
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
5
## CPI installation system
Peripherals overview
Integration of the CPI installation system in various connection concepts Centralised pneumatic connection (valve terminal)
## Disadvantages
## Advantages
- Pneumatic multiple connector plate • Only effective with a large number
- • Less tubing required than with of closely spaced actuators individual valves • Heavier than an individual valve
- Heavier than an individual valve (lower overall weight than the same number of individual valves), which may make assembly on moving systems or in very cramped installation spaces difficult
- Common valve air supply
- Central positioning
- Material, weight and cost savings
- Longer tube lengths are occasionally required, ruling out the possibility of optimum pneumatic performance
Decentralised pneumatic connection (individual valve/valve on individual sub-base)
## Advantages
## Disadvantages
- Can be positioned directly at the • Air supply per valve requires more actuator, can even be integrated tubing
- Short tubing length to the actuator • Serial electrical interlinking not enables short switching times advisable/possible
- Optimum pneumatic timing and • More complex electrical installation performance possible
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
6
## CPI installation system
Peripherals overview
## Integration of the CPI installation system in various connection concepts
Centralised electrical connection (multi-pin plug/fieldbus connection/standalone minicontroller)
## Disadvantages
## Advantages
- Internal electrical interlinking • Not suitable for individual, more requires less cabling widely separated applications due
- • Increased transparency to the more complex cabling
- Increased transparency
- Material, weight and cost savings • More complex individual compo-
- • Ideal for connecting a large number nents (cables, fieldbus modules) of closely spaced valves
Decentralised electrical connection (CPI system/individual valve/valve on individual sub-base/valve manifold)
## Advantages
## Disadvantages
- CPI system with reduced installa• Limited spatial expansion possible tion complexity for groups of (CPI system up to 10 m, actuators/sensors AS-interface up to 100 m)
- Different levels of complexity with • High installation costs widely separated individual components
- Easy replacement of components during servicing
- Optimum pneumatic timing and performance possible
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
7
## CPI installation system
Peripherals overview
## Integration of the CPI installation system in various connection concepts
Combined centralised and decentralised connection (valve terminal with CP interface/output module)
## Disadvantages
## Advantages
- Can be scaled to different requirements within a system
- Can be scaled to different require• Application must at least partially ments within a system meet the requirements of a
- • One control interface in the system, centralised connection reduces installation complexity with closely and widely spaced actuators
- Enables an optimum electrical and pneumatic control chain
## Connection of the CPI installation system to a higher-level controller Fieldbus node/Industrial Ethernet
Different bus nodes are used for • Profibus DP integration in the control systems of • Profinet various manufacturers. • Interbus The CPI system can therefore be oper• DeviceNet ated via more than 90% of the most • Ethernet IP commonly used fieldbus systems. • CANopen • CC-Link
- Profibus DP
- • Profinet • Interbus
## Control block
The optional Front End Controller • Ethernet CPX-FEC enables simultaneous access • TCP/IP via Ethernet and an integrated web • Web server, as well as autonomous preprocessing.
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
8
## CPI installation system
Peripherals overview
|Connection of th|e CPI installation system to a higher-level controller|e CPI installation system to a higher-level controller|e CPI installation system to a higher-level controller|
|---|---|---|---|
|Overview|||Bus protocol/fieldbus node<br>Special features|
|**FB6**<br>**FB11**<br>**FB13**<br>FB14<br>FB23<br>FB32<br>FB33<br>CPX-FEC|||Interbus<br>FB6<br>• Up to 96 digital inputs/outputs<br>• 6 analogue inputs/outputs<br>DeviceNet<br>FB11<br>• Up to 512 digital inputs/outputs<br>• 18 analogue inputs/outputs<br>Profibus DP<br>CP interface<br>FB13<br>• Up to 512 digital inputs/outputs<br>• 18 analogue inputs/outputs<br>CANopen<br>FB14<br>• Up to 64 digital inputs and 64 digi-<br>tal outputs<br>• 8 analogue inputs and 8 analogue<br>outputs<br>CC-Link<br>FB23<br>• Up to 64 digital inputs/outputs<br>• 16 analogue inputs/outputs<br>Ethernet/IP<br>FB32<br>• Up to 128 digital inputs/outputs<br>• 8 analogue inputs/outputs<br>PROFINET RT<br>FB33<br>• Up to 512 digital inputs/outputs<br>• 32 analogue inputs/outputs<br>EtherCAT<br>FB38<br>• Up to 512 digital inputs/outputs<br>• 32 analogue inputs/outputs<br>Control block FEC<br>• Modbus TCP<br>• Easy-IP<br>• Interbus, DeviceNet, Profibus DP,<br>CANopen and CC-Link via combina-<br>tion with CPX fieldbus node<br>• TCP/IP and web connection via<br>Ethernet interface<br>• Up to 512 inputs/outputs<br>• Several CP interfaces can be<br>connected<br>• Ethernet fieldbus slave in remote<br>I/O operating mode (T05)<br>• Autonomous control of the CPI sys-<br>tem as a remote controller (T03)|
|||CPX|CP interface|
|||||
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
9
## CPI installation system
Peripherals overview
## Connection of modules in the CPI installation system
## CP interface within the context of the CPX terminal
Using the CP interface as a module of the CPX terminal facilitates the progression from the CP system to the CPI system. All CP modules are both downwards and upwards compatible and can therefore be used in the CP system and in the CPI system.
This extension has doubled the scalability and range of CP modules that can be used:
- 4 CP strings
- Up to 4 modules per string
- Up to 32 inputs and outputs per CP string
An added advantage of the CPI system is its extremely user-friendly access possibilities via the CPX fieldbus node and the CPX-FEC:
- Data pre-processing
- Diagnostics via software
- Reading out of status information
- Display via permanently installed or mobile unit
- Remote maintenance with CPX-FEC and Ethernet connection
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
10
## CPI installation system
Connection options
|Fieldbus Direct|||
|---|---|---|
|Special feature|Application|Characteristics of Fieldbus Direct|
Characteristics of Fieldbus Direct • Extremely compact and spaceNote saving design -H• Low-cost solution for the connection The range of functions and comof a small number of valves to the bination options of CPV, CPV-SC, fieldbus CPA-SC, CDVI and MPA valves are • described in detail in
Fieldbus Direct is a system for the compact connection of a valve terminal to nine different fieldbus standards. The most important fieldbus protocols including Profibus, Interbus, DeviceNet and CANopen are supported. The CP string extension option allows the functions and components of the CPI installation system to be used.
The Fieldbus Direct product range is the most compact way of connecting valves to a fieldbus. The fieldbus node is directly integrated in the electrical actuation of the valve terminal and therefore takes up only a minimal amount of space.
- Direct front-end integration with a high degree of protection (IP65)
- Internet: type 80 (Valve terminal CPV-SC)
- Comprehensive diagnostics and condition monitoring
- Internet: cpasc (Valve terminal CPA-SC)
- � Internet: type 15 (Valve terminal CDVI)
- � Internet: type 10 (Valve terminal CPV)
- Internet: type 32 (Valve terminal MPA)
## Fieldbus Direct and CP string extension
The optional string extension allows a The maximum length of the CP string further valve terminal and I/O modextension is 10 metres, which means ules to be connected to the Fieldbus that the extension modules can be Direct fieldbus node. mounted directly on-site. All of the • A CP string of the CP system is required electrical signals including integrated in the fieldbus node as load current supply are transmitted an extension via the CP cable, which in turn means • Different input and output modules that no further installation is needed as well as CPV, CPA and MPA valve on the expansion module. terminals can be connected
The CP string interface offers:
- Max. 32 input signals
- Max. 32 output signals for output modules 24 V DC or solenoid coils
- Logic and sensor supply for the input modules
- Load voltage supply for the valve terminals
- Logic supply for the output modules
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
11
## CPI installation system
Connection options
**==> picture [488 x 597] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fieldbus Direct with CP string extension<br>CPV valve terminal<br>Fieldbus • 4 to 8 valve positions<br>• DeviceNet<br>• CANopen<br>• Profibus DP<br>• ABB CS31<br>• Interbus<br>• Moeller Suconet<br>• Festo fieldbus<br>• Beckhoff<br>• CC-Link<br>• 4 to 16 solenoid coils<br>Further information<br>� Internet: type 10<br>CPA-SC<br>Fieldbus • 4 to 24 valve positions<br>• DeviceNet connection<br>• Profibus DP<br>• 4 to 32 solenoid coils<br>Further information<br>� Internet: cpasc<br>CPV-SC<br>Fieldbus • 4 to 16 valve positions<br>• DeviceNet connection<br>• Profibus DP<br>• 4 to 16 solenoid coils<br>Further information<br>� Internet: type 80<br>CDVI-DN<br>Fieldbus • 4 to 16 valve positions<br>• DeviceNet connection<br>• 4 to 24 solenoid coils<br>Further information<br>I n � Internet: type 15<br>Ou t<br>0 1<br>2 3<br>4 5<br>6 7<br>**----- End of picture text -----**<br>
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
12
## CPI installation system
Connection options
- Positioning systems Application
- The SPC200 is a position controller The CP interface option enables the (closed loop) and positioning control functions and components of the CP (open loop) in one. Together with the installation system to be used. drive, the displacement encoder and the proportional directional control valve, it forms a closed control loop.
## Properties
- Modular with 9 different plug-in cards
- Flexible with set selection for positioning tasks with fixed trajectories and program mode with up to 100 programs
- Wide variety with up to 4 positionand program mode with up to 100 ing axes, stepper motor axes and programs the option of operating pneumatic • Quick commissioning using the and electrical systems WINPISA diagnostic and programming tool
## Positioning systems and CP interface
- The plug-in cards for connecting the The maximum length of the CP string axis strings facilitate the connection extension is 10 metres, which means of further input/output modules: that the extension modules can be • One CP string of the CP system is mounted directly on-site. All of the **possible as an extension required electrical signals including**
- • Various input and output modules load current supply are transmitted as well as CPV valve terminals can via the CP cable, which in turn means be connected that no further installation is needed on the extension module.
The CP string interface offers: Note • 16 input signals -H• 16 output signals for output CP input modules can only be modules 24 V DC or solenoid coils connected via a terminating resistor • **and sensor for the** (KZW-M9-R100).
- **Logic and sensor supply for the** input modules
- Load voltage supply for the valve terminals
- Logic supply for the output modules
## Axis controller SPC200 with CP interface
**==> picture [169 x 114] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fieldbus<br>**----- End of picture text -----**<br>
- Max. 64 inputs and 64 outputs via fieldbus
**==> picture [207 x 80] intentionally omitted <==**
**----- Start of picture text -----**<br>
fieldbus<br>• DeviceNet, Interbus or Profibus<br>connection<br>I n<br>Ou t<br>2 3 0 1 Further information<br>4 5 � Internet: spc200<br>6 7<br>**----- End of picture text -----**<br>
## Compact vision system SBOC-Q/SBOI-Q with CP interface
The compact vision system SBOx-Q can be integrated into a Festo CPI network. In this case it functions like a binary module with 16 inputs and outputs.
In combination with a CPX-CPI module and a CPX fieldbus, for example, the camera can be accessed via Profibus DP, Interbus, DeviceNet, CANopen and CC-Link.
- Address requirement: 16 digital inputs/outputs
- CPI connection
Further information
- Internet: sbo
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
13
## CPI installation system
Connection options
|Connection of|Connection of|Connection of|Connection of|Connection of|Connection of|Connection of|Connection of|Connection of|Connection of|Connection of|Connection of|Connection of|Connection of|Connection of|Connection of|Connection of|Connection of|input and|input and|input and|input and|input and|input and|input and|input and|input and|input and|input and|input and|input and|input and|output modules in the CPI installation system|output modules in the CPI installation system|output modules in the CPI installation system|output modules in the CPI installation system|output modules in the CPI installation system|output modules in the CPI installation system|output modules in the CPI installation system|output modules in the CPI installation system|output modules in the CPI installation system|output modules in the CPI installation system|output modules in the CPI installation system|output modules in the CPI installation system|output modules in the CPI installation system|output modules in the CPI installation system|output modules in the CPI installation system|output modules in the CPI installation system|output modules in the CPI installation system|output modules in the CPI installation system|output modules in the CPI installation system||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|CP||||connecting||||||||||||||cable||||||||||||||||||||||||||||||||||||
||||||||||||||||||||||||||||||||||||||||||||||||||KVI-CP-3-…||• Pre-assembled cables for||Further information|
||||||||||||||||||||||||||||||||||||||||||||||||||-H-<br>Note<br>The total length of all CP cables in a<br>CP string must not exceed 10 m.||**connecting** **the** **CP** **modules**<br>• Lengths from 0.25 to 8 metres<br>• M9 plug/socket, 5-pin<br>• Straight/angled version in any<br>combination||**�Internet:** **kvi-cp**|
|CP||||input/output|||||||||||||||||modules||||||||||||in|||sturdy,||||||||||universal and compact design or as a valve terminal||||||||
|The||||connection||||||||||||||technology for|||||||||||||||||||the|||||sen-|||||||• M12-5PIN||The maximum number of inputs/out-||• Input modules with 8, 16 or|
|sors|||||and|||||additional||||||||||||||actuators|||||||||||||offers||||||||a||||• M8-3PIN||puts that can be connected to the||32 channels|
|wide range|||||||||||||of|||digital||||||||||and analogue|||||||||||||||||||||||• M8-4PIN||individual modules can vary||• Output modules with 4 or|
|input||||||and|||||output||||||||||modules||||||||||||and is||||||||||||||||• Spring-loaded terminal or screw ter-||depending on the application. The||8 channels|
|freely||||||selectable –||||||||||||||||depending|||||||||||||||on||||your||||||||minal technology||following module sizes are available:||• CPV with 4, 6 or 8 valve slices (max.|
|standard or application:|||||||||||||||||||||||||||||||||||||||||||||||||||||16 valves)|
||||||||||||||||||||||||||||||||||||||||||||||||||||||• MPA with 2 … 32 valves|
||||||||||||||||||||||||||||||||||||||||||||||||||||||• CPV-SC with 4 … 16 valves|
||||||||||||||||||||||||||||||||||||||||||||||||||||||• CPA with 2 … 16 valves|
|Valve|||||||terminals||||||||||||||with|||||||CP||||interface||||||||||||||||||||||
|CPV valve||||||||||||terminal||||||||||||||||||||||||||||||||||||||||||
||||||||||||||||||||||||||||||||||||||||||||||||||CPV10||• Max. 16 valves in 8 valve slices||Further information|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
||||||||||||||||||||||||||||||||||||||||||||||||||CPV14||• Highly compact and space-saving||�Internet: type 10|
||||||||||||||||||||||||||||||||||||||||||||||||||CPV18||• Width 10, 14, 18 mm||(Valve terminal CPV)|
||||||||||||||||||||||||||||||||||||||||||||||||||||• Nominal flow rate<br>400/800/1600 l/min|||
||||||||||||||||||||||||||||||||||||||||||||||||||||• CPV10 and CPV14 with CPI|||
|||||||||||||||||||||||||||||||||||||||||||||||||||||functionality||
||||||||||||||||||||||||||||||||||||||||||||||||||||• CPV18 with CP functionality|||
|MPA||||||valve|||||||terminal|||||||||||||||||||||||||||||||||||||||||
||||||||||||||||||||||||||||||||||||||||||||||||||MPA1||• Max. 32 valves||Further information|
||||||||||||||||||||||||||||||||||||||||||||||||||MPA2||• Modular and versatile||�Internet: type 32|
||||||||||||||||||||||||||||||||||||||||||||||||||||• Width 10, 20 mm||(Valve terminal MPA)|
||||||||||||||||||||||||||||||||||||||||||||||||||||• Nominal flow rate 360/700 l/min|||
||||||||||||||||||||||||||||||||||||||||||||||||||||• CPI functionality|||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
|CPV-SC valve|||||||||||||||||terminal|||||||||||||||||||||||||||||||||||||
||||||||||||||||||||||||||||||||||||||||||||||||||CPV-SC||• Max. 16 valves||Further information|
||||||||||||||||||||||||||||||||||||||||||||||||||||• Extremely compact||�Internet: type 80|
||||||||||||||||||||||||||||||||||||||||||||||||||||• Width 10 mm||(Valve terminal CPV-SC)|
||||||||||||||||||||||||||||||||||||||||||||||||||||• Nominal flow rate 170 l/min|||
||||||||||||||||||||||||||||||||||||||||||||||||||||• CPI functionality|||
|CPA valve||||||||||||terminal||||||||||||||||||||||||||||||||||||||||||
||||||||||||||||||||||||||||||||||||||||||||||||||CPA10||• Max. 16 valves||Further information|
||||||||||||||||||||||||||||||||||||||||||||||||||CPA14||• Width 10, 14 mm||�Internet: type 12|
||||||||||||||||||||||||||||||||||||||||||||||||||||• Nominal flow rate 300/600 l/min<br>• CP functionality||(Valve terminal CPA)|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
14
## CPI installation system
Key features – Input/output modules
Connection of input and output modules in the CPI installation system Special features of the CP input/output modules of sturdy design
The sturdy CP input/output modules As a CP-E…Z or output modules they have a highly resistant aluminium have a separate load voltage supply, housing and its internal electronic which means less load on the CP intercomponents can be repaired or face and CP cable and more power for replaced.
the connected consuming devices. This also facilitates separate disconnection of the consuming devices.
High degree of protection (IP65), surpassed only by the compact CP modules with IP65/67 protection. The only exception is the IP20 protection offered by the module with clamped terminal connection for installation in control cabinets.
CP input modules of sturdy design
- CP-E16-M12x2-5POL • 16 inputs 24 V DC • M12 plug, double allocation CP-E16N-M12x2 • Signal status display via 16 LEDs • 1x M9 CP connection • Operating status display • PNP/NPN, IP65 • CP functionality
- CP-E16-M8 • 16 inputs 24 V DC • M8 plug, single allocation CP-E16N-M8 • Signal status display via 16 LEDs • 1x M9 CP connection • Operating status display • PNP/NPN, IP65 • CP functionality
- CP-E16-M8-Z • 16 inputs 24 V DC • Galvanic isolation through • Signal status display via 16 LEDs additional power supply • Operating status display • M8 plug, single allocation • CP functionality • 1x M9 CP connection • Separate sensor supply • PNP/NPN, IP65
- CP-A08-M12-5POL • 8 outputs 24 V DC • 2x M9 CP connection CP-A08N-M12 • Output signal display via 8 LEDs • Separate load voltage • Operating status display • Outputs resistant to overloads and • M12 plug, single allocation short circuits • CP functionality • PNP/NPN, IP65
- CP output modules of sturdy design CP-A08-M12-5POL • 8 outputs 24 V DC CP-A08N-M12 • Output signal display via 8 LEDs • Operating status display • M12 plug, single allocation • CP functionality
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
15
## CPI installation system
Key features – Input/output modules
- Connection of input and output modules in the CPI installation system Special features of the CP input/output modules of economical design
- In addition to the sturdy CP input/ The economical CP modules feature a Application: • The maximum number of modules output modules and the compact CP compact design, coupled with a large • Same function, configuration and per CP string is as follows: –
- input/output modules, there are also number of inputs/outputs. commissioning as sturdy or CPI system: max. 4 modules or the economical modules with the deThe modules can be used in compact CP modules max. 32 inputs and 32 outputs sign features of the compact modules, connection with the following valve • Integrated H-rail mounting and – CP system: one valve terminal/ but with a greater number of inputs/ terminals: earthing plate output module and one input outputs. – CPV, MPA, CPV-SC, CPA-SC, CDVI, • Centrally placed status and module CPA diagnostic LEDs • The economical CP modules and the other CP modules can be operated together on a string
- CP input modules of economical design CP-E16-M12-EL • 16 inputs 24 V DC • 8x M12 plug, 5-pin, double • Signal status display via 16 LEDs allocation • Operating status display (per mod• 2x M9 CP connection ule and per group of four inputs) • PNP, IP65
- • CPI functionality
- CP-E16-M8-EL • 16 inputs 24 V DC • 16x M8 plug, 3-pin, single • Signal status display via 16 LEDs allocation • Operating status display (per mod• 2x M9 CP connection ule and per group of four inputs) • PNP, IP65
- • CPI functionality
- CP-E32-M8-EL • 32 inputs 24 V DC • 16x M8 plug, 4-pin, double • Signal status display via 32 LEDs allocation • Operating status display • 2x M9 CP connection (per module) • PNP, IP65
- • CPI functionality
- CP output modules of economical design CP-A08-M12-EL-Z • 8 outputs 24 V DC • 8x M12 plug, 5-pin, double • Signal status display via 4 LEDs allocation • Operating status display (per mod• 2x M9 CP connection ule and per channel/output) • Outputs resistant to overloads and
- • CPI functionality short circuits • PNP, IP65
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
16
## CPI installation system
Key features – Input/output modules
Connection of input and output modules in the CPI installation system Special features of the CP input/output modules of compact design
The compact CP modules are designed for use in handling and assembly wherever space requirements and product weight play a role. The modules can be used in connection with the following valve terminals:
In addition to the sturdy and economiThe compact CP modules are designed cal CP input/output modules, there is for use in handling and assembly also the compact series of CP input/ wherever space requirements and output modules. These have an product weight play a role. optimised, compact design, are made The modules can be used in connecfrom plastic and are very light. They tion with the following valve are, of course, available with the high terminals: – degree of protection IP65/67 (excepCPV, MPA, CPV-SC, CPA-SC, CDVI, tion: terminal modules in IP20 for inCPA stallation in a protected fitting space).
## Application:
- The modules can be positioned closer to the actuators thanks to the smaller dimensions
- Same function, configuration and commissioning as sturdy or economical CP modules
- The compact CP modules and the other CP modules can be operated together on a string
- The maximum number of modules per CP string is as follows: – CPI system: max. 4 modules or max. 32 inputs and 32 outputs
- – CP system: one valve terminal/ output module and one input module
## CP input modules of compact design
**==> picture [82 x 57] intentionally omitted <==**
**----- Start of picture text -----**<br>
In<br>Ou t<br>1<br>3<br>5<br>7<br>**----- End of picture text -----**<br>
**==> picture [89 x 56] intentionally omitted <==**
**----- Start of picture text -----**<br>
In<br>Ou t<br>0 1<br>2 3<br>4 5<br>6 7<br>**----- End of picture text -----**<br>
CP-E08-M12x2-CL
CP-E08-M8-CL
CP-E16-KL-CL
- 8 inputs 24 V DC
- Signal status display via 8 LEDs
- Operating status display
- CPI functionality
- 8 inputs 24 V DC
- Signal status display via 8 LEDs
- Operating status display
- CPI functionality
- 16 inputs 24 V DC
- Indirect signal status display via LEDs in the connection set of the tension-spring socket
- 4x M12 plug, 5-pin, double allocation
- 2x M9 CP connection
- PNP, IP65/67
- 8x M8 plug, 3-pin, single allocation
- 2x M9 CP connection
- PNP, IP65/67
- Screw terminal or tension-spring sockets
- 2x M9 CP connection
- PNP, IP20
- Operating status display
- CPI functionality
CP output modules of compact design
CP-A04-M12x2-CL
- 4 outputs 24 V DC
- Signal status display via 4 LEDs
- Operating status display
- CPI functionality
- 4x M12 plug, 5-pin, double allocation
- 2x M9 CP connection
- Outputs resistant to overloads and short circuits
- PNP, IP65/67
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
17
## CPI installation system
Key features – Mounting options
H-rail mounting CP interface The H-rail mounting is formed in the reverse profile of the CPX interlinking A blocks. The CPX terminal can be attached to the H-rail using the H-rail mounting. B Economical CP modules The H-rail mounting is impressed in the reverse profile of the economical A CP modules. The modules can be attached to the H-rail using the H-rail mounting. B Compact and sturdy CP modules
The CPX terminal is attached to the The following mounting kit is required H-rail as follows (see arrow A). for H-rail mounting (plus mounting kit It is first swivelled on the H-rail and for optionally mounted valves): then secured in place with the • CPA-BG-NRH clamping component (see arrow B). This enables mounting on H-rails to EN 60715.
The scope of delivery includes the following mounting kit for H-rail mounting:
The module is attached to the H-rail The scope of delivery includes the as follows (see arrow A). following mounting kit for H-rail It is first swivelled on the H-rail and mounting: then secured in place with the • CP-EL-HS clamping component (see arrow B). This enables mounting on H-rails to EN 60715.
The following mounting kit is required for H-rail mounting:
For the CP modules there is a mounting kit that can be used on an H-rail. On the compact CP modules, the mounting holes are covered by inscription labels.
• CP-TS-HS35 This enables mounting on H-rails to EN 60715.
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
18
## CPI installation system
Key features – Mounting options
Wall mounting CP modules
The CP modules (with screws up to 4 mm in diameter) can be mounted on even surfaces in almost any position using the mounting holes.
Note -HThe mounting holes on the compact CP modules are covered by inscription labels.
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
19
## CPI installation system
Key features – Inscription system
|Inscription system||
|---|---|
|ll CP modules have hold<br>nscription labels.|ers for<br>Inscription labels/holders are not<br>included in the scope of delivery and<br>can be ordered separately.<br>The labels can be pre-assembled on<br>request.|
|Robust CP modules||
|IBS6x10|The sturdy CP modules have two slots<br>in which the inscription labels<br>IBS6x10 (Part No. 18576) can be<br>fitted. At least one inscription label<br>can be fitted per connection.<br>The IBS6x10 are plastic clips that can<br>be printed on, written on or affixed<br>with labels.|
|Economical CP modules||
||ASCF-H-E2<br>The economical CP modules have six<br>lateral fixtures for one inscription<br>label holder ASCF-H-E2 each (Part<br>No. 547473).<br>The ASCF-H-E2 are transparent hinged<br>label holders for holding pre-as-<br>sembled paper inscription labels.<br>The label can be read when the label<br>holder is opened out.|
|Compact CP modules||
|IBS8x2|0<br>The compact CP modules have a<br>holder for an inscription label<br>IBS8x20 (Part No. 539388) for each<br>connection.<br>The IBS8x20 are plastic clips that can<br>be printed on, written on or affixed<br>with labels.|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
20
## CPI installation system
Key features – Power supply
- Operating voltage and load current supply
- The following functions are made CP-E…Z or output modules from the Every module in the CPI system is 700 mA in the economical design with available to the connected modules sturdy and the economical series have protected separately against overload 16 inputs and 1400 mA with 32 inthrough the CP cable: a separate load voltage supply: with electronic fuses. puts. • Connection for data exchange • Less load on the CP interface and CP The input modules without additional The input modules with additional • Operating voltage for internal cable supply provide a maximum sensor supply provide up to 2 A residual electronics • 0.5 A per output (max. 4 A supply supply of 500 mA in the sturdy design, current for the connected sensors.
- • Load current supply for the per output module) 800 mA in the compact design and connected inputs/sensors and/or • 1 A per 8 inputs outputs/actuators • Separate disconnection of the consuming devices possible
**==> picture [489 x 169] intentionally omitted <==**
**----- Start of picture text -----**<br>
Example of circuits for additional power supply<br>2 1 1 Load voltage supply (can be<br>disconnected separately)<br>2 External fuses<br>10 A 3 Protective earth<br>4 Equipotential bonding<br>24 V DC 3.15 A 5 Earth terminal on pin 4, rated for<br>AC 12 A<br>DC 0 V<br>3 4 5<br>**----- End of picture text -----**<br>
|Pin allocation of plug for additional power supply|Pin allocation of plug for additional power supply|Pin allocation of plug for additional power supply|Pin allocation of plug for additional power supply|Pin allocation of plug for additional power supply|Pin allocation of plug for additional power supply|
|---|---|---|---|---|---|
|Pin allocation|||Pin|Signal|Designation|
||||1|24 V DC|Supply for electronics and inputs|
||||2|24 V DC|<br>Load supply for valves/outputs|
||||3|0 V|Equipotential bonding|
||||4|0 V|Earth terminal and equipotential bonding, rated for 12 A|
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
21
## CPI installation system
Key features – Power supply
## Power supply concept of the CPX terminal
Circuit diagram for M18 power supply/system supply (example)
**==> picture [69 x 64] intentionally omitted <==**
The use of decentralised devices on the fieldbus – particularly with high protection for direct machine mounting – demands a flexible power supply concept.
The CPX terminal facilitates the connection of all voltages via one socket.
A distinction is made between supply for
- electronics and sensors/inputs
- valves
- actuators/outputs
Selectable connecting thread:
- M18
- 7/8’’
- AIDA push-pull
System supply
Note -H-
The CP interface connects the 0 V of the power supply for the electronics/ inputs and the valves. To prevent overloads, the power must therefore
be supplied using just one power supply module or using power supply units with a common earthed conductor.
## Interlinking blocks
Many applications require segmenting of the voltage into zones. This is true in particular of the separate disconnection of connected actuators (solenoid coils/outputs). The separation of voltages for valves and the realisation of different voltage segments for electrical outputs and sensors are supported by the different
interlinking blocks of the CPX terminal:
- With system supply
- Without power supply
- With additional power supply for electrical outputs
- With additional power supply for valves
The supply voltages are supplied using a
- 4-pin M18 plug
- 4-pin 7/8’’ plug
- 5-pin 7/8’’ plug
- AIDA push-pull, 5-pin
Note -H-
The max. current is limited to 12 A with the 7/8’’ system supply. When using a conventional preassembled cable, the max. current is limited to 8 A.
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
22
## CPI installation system
Key features – Diagnostics
|General limits||||
|---|---|---|---|
|System supply|CP interface|||
|The system supply provides the inter-|The CP interface and the CP modules|The operating voltage for the sensors/|connected CP modules with|
|nal voltage for the entire CPX system|connected to the CP interface get their|actuators connected to the CP mod-|The CP interface supplies the|
|with|operating voltage from the connection|ules is supplied from the voltage for|connected CP modules with|
|• max. 16 A for electronics and|for electronics and sensors/inputs.|valves. The CP interface supplies the|• max. 1.6 A per CP string|
|sensors/inputs||||
- max. 16 A for actuators/outputs and valves
- Diagnostics General information Diagnostics via LED Diagnostics via control program/CPX-MMI
- A comprehensive diagnostic function • Error in bus communication • Configuration error • Operating voltage failure at the is available for each string. • POWER, power supply display for • Bus error output modules The diagnostic information can either internal electronics • Operating voltage failure • Short circuit/overload at the output be detected via the LEDs on the mod• POWER V, load voltage display for • Falling below voltage tolerance modules ule and then read out and evaluated valves (valves) • Connection to one or more CP modvia the controller software (non-field• 0 … 3, CP string allocation changed • Short circuit in sensor voltage ules interrupted (valve terminal, bus-specific) or displayed directly on or interrupted supply input/output modules) the CPX terminal via the CPX-MMI and There are also bus-specific LED then evaluated and edited. displays.
- Operating voltage failure at the output modules
- • Short circuit/overload at the output modules
Diagnostics via CPX terminal
**==> picture [446 x 253] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>2<br>4 4 4<br>3<br>5<br>1 Diagnostics via controller/<br>fieldbus node<br>2 Bus-specific LED<br>3 String diagnostics via LED on the<br>CP interface<br>4 Diagnostics via CP string<br>5 Diagnostics via LED on CP<br>module<br>6 6 Status display on the CP module<br>**----- End of picture text -----**<br>
- 3 String diagnostics via LED on the CP interface
- 6 Status display on the CP module
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
23
## CPI installation system
Key features – CP interface
**==> picture [488 x 204] intentionally omitted <==**
**----- Start of picture text -----**<br>
Diagnostics<br>Diagnostics via CP fieldbus node<br>Fieldbus<br>1<br>2 5 5<br>3 1 Diagnostics via fieldbus<br>6 2 String diagnostics via LED on the<br>4 fieldbus node<br>3 Bus-specific LED<br>4 Diagnostics via LED on<br>the CP module<br>6<br>5 Diagnostics via CP string<br>6 Status display on the<br>CP module<br>**----- End of picture text -----**<br>
- 6 Status display on the CP module
## Diagnostic LEDs on the CP modules
**==> picture [191 x 128] intentionally omitted <==**
**----- Start of picture text -----**<br>
2 3 4<br>1<br>**----- End of picture text -----**<br>
- 1 Status LED for
- CP communication (PS, green)
- 2 Status LED (module) for short circuit/overload of sensor supply (red)
- 3 Status LEDs for inputs (status display, green)
- 4 Status LED (group, only with CP-E16-…-EL) for short circuit/ overload of sensor supply (red)
- In addition to the status display per module and per individual channel/ input, the economical modules with 16 inputs additionally have a status display for a group of four inputs. The following inputs are combined into groups of four:
- 0 … 3
- 4 … 7
- 8 … 11
- 12 … 15
## Parameterisation
Allocation of the addresses to the individual actuators/outputs or sensors/inputs connected to the CP modules is performed in accordance with the fieldbus node or CPX-FEC used (exception: Interbus node). Address allocation is performed in accordance with the following rules:
- One CP interface provides four strings with a total of 128 inputs and 128 output addresses.
- A used string occupies 32 inputs and 32 output addresses.
- The addresses are permanently allocated to the strings and CP modules in ascending order.
- Unused address space remains reserved for future extensions.
The CP interface checks the configuration of the connected modules each time the system is switched on and during operation. If a deviation from the saved configuration is detected, an appropriate message is output via the controller software and displayed via LED.
The configuration detected is stored by pressing the Save button (after the operating voltage is switched on at the CP interface).
The configuration is stored each time the CP interface is switched off and back on.
The option is provided of replacing a connected CP module with a module of identical design during operation. Removal of more than one module from the current configuration will be detected as an error; the address spaces of these modules will no longer be actuated.
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
24
## CPI installation system
Selection aid
|System selection aid|System selection aid|System selection aid|System selection aid|System selection aid|System selection aid|
|---|---|---|---|---|---|
||Modules per<br>string|Outputs/inputs per string<br>|Modules with CP functionality|Modules with CPI functionality|String length<br>[m]|
|CP system|2|16/16<br>0<br>0|… 1 input module<br>… 1 output module|0 … 1 input module<br>0 … 1 output module|0 … 10|
|CPI system|4|32/32<br>0<br>0|… 1 input module<br>… 1 output module|0 … 4 input modules<br>0 … 4 output modules|0 … 10|
|Module selection aid||||||||
|---|---|---|---|---|---|---|---|
||Functionality||Additional<br>**p**ower su**pp**l**y**|Address requirement||Max. current<br>consumption|�Page/Internet|
||CP|CPI||Inputs|Outputs|[A]||
|Input modules||||||||
|CP-E16-M8|�|–|–|16|–|0.54|47|
|CP-E16N-M8|�|–|–|16|–|0.59|47|
|CP-E16-M12x2-5POL|�|–|–|16|–|0.59|47|
|CP-E16N-M12x2|�|–|–|16|–|0.59|47|
|CP-E16-M8-Z|�|–|�|16|–|1.04|47|
|CP-E32-M8-EL|–|�|–|32|–|1.4|53|
|CP-E16-M8-EL|�|�|–|16|–|0.7|53|
|CP-E16-M12-EL|�|�|–|16|–|0.7|53|
|CP-E08-M12-CL|�|�|–|8|–|0.835|59|
|CP-E08-M8-CL|�|�|–|8|–|0.835|59|
|CP-E16-KL-CL|�|�|–|16|–|0.835|59|
|||||||||
|Output modules||||||||
|CP-A08-M12-5POL|�|–|�|–|8|2.09|65|
|CP-A08N-M12|�|–|�|–|8|2.09|65|
|CP-A08-M12-EL-Z|�|�|�|–|8|4|69|
|CP-A04-M12-CL|�|�|–|–|4|1.035|73|
|||||||||
|Connecting cables||||||||
|KVI-CP-3-…|�|�|–|–|–|1.6|kvi-cp|
|||||||||
|Valve terminals||||||||
|CPV10-FB-4|�|�|–|–|16|0.327|type 10|
|CPV10-FB-6|�|�|–|–|16|0.465|type 10|
|CPV10-FB-8|�|�|–|–|16|0.604|type 10|
|CPV14-FB-4|�|�|–|–|16|0.419|type 10|
|CPV14-FB-6|�|�|–|–|16|0.603|type 10|
|CPV14-FB-8|�|�|–|–|16|0.788|type 10|
|CPV18-FB-4|�|�|–|–|16|0.624|type 10|
|CPV18-FB-6|�|�|–|–|16|0.911|type 10|
|CPV18-FB-8|�|�|–|–|16|1.197|type 10|
|CPA10|�|–|–|–|16|0.31|type 12|
|CPA14|�|–|–|–|16|0.5|type 12|
|MPA|–|�|�|–|32|3.25|type 32|
|CPV-SC|–|�|–|–|16|0.875|type 80|
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
25
## CPI installation system
Selection aid
Accessory selection aid Connection M8, 3-pin
**==> picture [176 x 234] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>2<br>3<br>In<br>Ou t<br>0 1<br>2 3<br>4 5<br>6 7<br>**----- End of picture text -----**<br>
Note -HFesto delivers pre-assembled M8/M12 connecting cables (NEBU modular system) on customer request: • application tailored
- perfectly fitting
- installation saving
|dules|Plug connector/connecting cable|Plug connector/connecting cable|
|---|---|---|
||Type<br>Con|nection technology|
||2 Plug connector||
||SEA-GS-M8<br>Sol|der lug|
||SEA-3GS-M8-S<br>Scr|ew terminal|
||||
||3 Connecting cable||
||KM8-M8-GSGD-…<br>Soc|ket M8, 3-pin|
||NEBU-…-M8G**3**<br>Soc<br>Soc<br>Soc<br>Soc<br>Op|ket M5, 3-pin|
|||ket M8, 3-pin|
|||ket M8, 4-pin|
|||ket M12, 5-pin|
|||en cable end|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
26
## CPI installation system
Selection aid
Accessory selection aid Connection for inputs M8, 4-pin
**==> picture [298 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
4 Note<br>-H-<br>2 Festo delivers pre-assembled<br>M8/M12 connecting cables (NEBU<br>5 modular system) on customer<br>request:<br>• application tailored<br>• perfectly fitting<br>• installation saving<br>3<br>**----- End of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|1|Input modules|||Plug connector/connecting cable||
|Type||||Type<br>Con|nection technology|
|CP-E**3**2-M8-EL||||2 T-adapter||
|||||NEDU-M8D**3**-M8T4<br>2x s|ocket M8**,** **3**-**p**in|
|||||||
|||||3 Connecting cable||
|||||NEBU-…-M8G4<br>Soc<br>Soc<br>Soc<br>Soc<br>Ope|ket M5, 3-pin|
||||||ket M8, 3-pin|
||||||ket M8, 4-pin|
||||||ket M12, 5-pin|
||||||n cable end|
|Plug connector/connecting cable|Plug connector/connecting cable||
|---|---|---|
|Connection technology|Type|Connection technology|
|4 Plug connector|||
|Plug M8, 3-pin|SEA-GS-M8|Solder lug|
|Plug M8, 3-pin|SEA-3GS-M8-S|Screw terminal|
||||
|5 Connecting cable|||
|Plug M8, 3-pin|KM8-M8-GSGD-…|Socket M8, 3-pin|
|Plu**g**M8**,** **3**-**p**in|NEBU-…-M8G**3**|Socket M5, 3-pin|
|||Socket M8, 3-pin|
|||Socket M8, 4-pin|
|||Socket M12, 5-pin|
|||Open cable end|
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
27
## CPI installation system
Selection aid
|Accessory selection aid|Accessory selection aid|Accessory selection aid|Accessory selection aid|||||||
|---|---|---|---|---|---|---|---|---|---|
|Connection for|inputs M12, 4-pin|||||||||
||||||2<br>3<br>4||5<br>6<br>-H-<br>Note<br>Festo delivers pre-assembled<br>M8/M12 connecting cables (NEBU<br>modular system) on customer<br>request:<br>• application tailored<br>• perfectly fitting<br>• installation saving|||
||1|||||||||
|||||||||||
|||||||||||
|||||||||||
|1 Input mod|ules||Plug connector/connecting c||able||Plug connector/connecting cable|||
|Type|||Type<br>Conne||ction technology||Connection technology|Type|Connection technology|
|CP-E16N-M12x2|||2 T-adapter||||5 Plug connector|||
||||NEDU-<br>2x so<br>M12D5-M12T4M||cket M12**,**4-**p**in||Plug M12, 4-pin|SEA-GS-7|Screw terminal|
||||||||Plug M12, 4-pin|SEA-4GS-7-2,5|Screw terminal|
|||||||||||
||||||||6 Connecting cable|||
||||3 Connecting cable||||Plug M12, 4-pin|KM12-M12-…|Socket M12, 4-pin|
||||KM12-DUO-M8-…<br>2x so||cket M8, 3-pin|||||
||||KM12-M12-…<br>Socke||t M12, 4-pin|||||
|||||||||||
||||4 Plug connector|||||||
||||SEA-GS-7<br>Screw||terminal|||||
||||SEA-4GS-7-2,5<br>Screw||terminal|||||
||||SEA-GS-11-DUO<br>Screw||terminal|||||
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
28
## CPI installation system
Selection aid
|ction aid|ction aid|ction aid||||
|---|---|---|---|---|---|
|inputs M12, 5-pin<br>1<br>2<br>~~In~~<br>Out<br>1<br>dules<br>2 Plug connector<br>Type<br>Connection technology<br>2-5POL<br>**-EL**<br>SEA-M12-5GS-PG7<br>Screw terminal<br>L<br>SEA-5GS-11-DUO<br>Screw terminal|||Connection for inputs, tension-spring socket<br>1<br>2<br>1 Input modules<br>2 Plug connector<br>Type<br>Type<br>Connection technology<br>CP-E16-KL-CL<br>PS1-SAC31-30POL+L<br>**ED**<br>Screw-in tension-<br>**spring** **socket**|||
|1<br>~~In~~<br>Out<br>1<br>dules<br>2-5POL<br>**-EL**<br>L||||2<br>2 Plug connector<br>Type<br>Connection technology<br>PS1-SAC31-30POL+L<br>**ED**<br>Screw-in tension-<br>**spring** **socket**||
||2 Plug connector||1 Input modules|||
||Type<br>C|onnection technology|Type||tion technology|
||SEA-M12-5GS-PG7<br>S|crew terminal|CP-E16-KL-CL||n tension-<br>**socket**|
||SEA-5GS-11-DUO<br>S|crew terminal||||
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
29
## CPI installation system
Selection aid
|Accessory selection aid|Accessory selection aid|Accessory selection aid||||||
|---|---|---|---|---|---|---|---|
|Connection for|outputs M12, 4-pin||||outputs M12, 5-pin|||
||||||1<br>odules<br>POL<br>L-Z<br>L|2||
|||||||||
|1 Output modules||Plug connector/connecting cable||||2 Plug connector||
|Type||Type<br>Con||nection technology||Type<br>C|onnection technology|
|CP-A08N-M12||2 Connecting cable||||SEA-M12-5GS-PG7<br>S|crew terminal|
|||KM12-M12-…<br>Soc||ket M12, 4-pin||SEA-5GS-11-DUO<br>S|crew terminal|
|||||||||
|||3 Plug connector||||||
|||SEA-GS-7<br>Scr||ew terminal||||
|||SEA-4GS-7-2,5<br>Scr||ew terminal||||
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
30
## CPI installation system
Technical data – Fieldbus node CP-FB05-E
This fieldbus node handles communication between the decentralised CP system and a higher-order master. The fieldbus node is a slave station on the fieldbus and represents the I/O data and diagnostic information of the connected CP modules on the network. For the electrical peripherals, this module provides the separate electrical system supply for
- the electronics modules and sensor supply, and
- the load current of the valves.
- The FB5 fieldbus node supports three different company-specific fieldbus protocols, based on a floating RS485 connection. The required protocol is selected by means of switch settings.
- Festo fieldbus
- ABB CS31
- Moeller SUCONET K
## Application
Bus connection
The bus connection on the FB5 is established by means of a 9-pin Sub-D plug. In the case of operation on the fieldbus, the incoming control signals from the node via the fieldbus are per-
manently forwarded to the connected
CP modules. The CP modules ensure that the programmed output signals are present or switch the relevant valves.
Note -HAlternatively the bus connection can be established via a 2x M12 adapter plug (B-coded).
~~rr~~ Implementation
Implementation The FB5 supports the digital input and output modules and the solenoid coils. It can service a total of 64 digital
outputs, of which max. 4x 16 can include solenoid coils, and 64 digital inputs.
Note -HPlease observe the general guidelines on I/O addressing when assigning the outputs.
Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
31
## CPI installation system
Technical data – Fieldbus node CP-FB05-E
|General technical data|||
|---|---|---|
|Type||CP-FB05-E|
|Baud rates|Festo fieldbus<br>[kbps]|Set using HW switch<br>• 31.25<br>• 62.50<br>• 187.50<br>• 375|
||ABB CS31<br>[kbps]|187.50|
||Moeller SUCONET K<br>[kbps]|Baud rate set automatically<br>• 187.50<br>• 375|
|Addressin**g**ran**g**e|Festo fieldbus|1 … 98|
||ABB CS31|0 … 60|
||Moeller SUCONET K|1 … 98|
|T**yp**e of communication|Festo fieldbus|Cyclic polling|
||ABB CS31|I16, O16 or I/O16|
||Moeller SUCONET K|Up to 32 I/O: SIS-K-06/07<br>Up to 64 I/O: SIS-K-10/10|
|Max. no. of solenoid coils||64|
|Max. no. of outputs incl. solenoid coils||64|
|Max. no. of inputs||64|
|LED dia**g**nostic indicators|Power|Power supply indicator for internal electronics|
||Power V|Power supply indicator for valves|
||0…3|CP string LED|
||Bus|Bus error status|
|Device-specific diagnostics transmitted to the controller||• Short circuit/overload of outputs<br>• Undervoltage of valves<br>• Undervoltage of outputs<br>• Undervoltage of sensor supply|
|O**p**eratin**g**volta**g**e|Nominal value<br>[V DC]|24 polarity-safe|
||Permissible range<br>[V DC]|20.4 … 26.4|
||Power failure buffering<br>[ms]|20|
|Current consum**p**tion**p**in 1|Fieldbus node<br>[mA]|250|
||CP modules<br>[mA]|560 (internal electronics) + total current consumption of inputs|
|Current limiting|Electronics of fieldbus node and<br>CP connection<br>[A]|Max. 1.25, short circuit proof|
|Load voltage pin 2|Solenoid valves|Total of all valves switched simultaneously, see technical data on CP valves<br>�Internet: type 10 and Internet: type 12<br>Compact Performance valve terminals CPV and CPA|
|Current limiting|Supply for solenoid valves<br>[A]|Max. 2.5, fused|
|Approval||CE|
|Protection class to EN 60529||IP65|
|Tem**p**erature ran**g**e|Operation<br>[°C]|–5 … +50|
||Storage<br>[°C]|–20 … +70|
|Materials|Housing|Die-cast aluminium|
|Dimensions (LxWxD)|[mm]|196.4 x 88 x 61.5|
|Weight|[g]|925|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
32
## CPI installation system
Technical data – Fieldbus node CP-FB05-E
|Certifications|Certifications|
|---|---|
|This product is certified for operation in the EX range as per EU-ATEX guideline||
|ATEX category gas|II 3G|
|Ex-ignition protection type gas|Ex na II T5 X|
|ATEX category dust|II 3D|
|EX-ignition protection type dust|Ex tD A22 IP65 T80° C X|
|ATEX ambient temperature<br>[°C]|–5 ≤Ta ≤+50|
|Certification|c UL us recognized (OL)|
|CE mark (see declaration of conformity)|In accordance with EU explosion protection directive (ATEX)|
**==> picture [489 x 231] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection and display components<br>1<br>6<br>2<br>3<br>5<br>1 Plug for fieldbus cable<br>2 Operating voltage connection for<br>CP and valves<br>4 3 Operating voltage LEDs<br>4 String LEDs<br>5 Save key<br>6 Bus-specific LED<br>**----- End of picture text -----**<br>
|Pin allocation for fieldbus interface (plug view)|Pin allocation for fieldbus interface (plug view)|Pin allocation for fieldbus interface (plug view)|Pin allocation for fieldbus interface (plug view)|Pin allocation for fieldbus interface (plug view)||||||
|---|---|---|---|---|---|---|---|---|---|
|Plu**g**view||Pin|Si**g**nal|Festo Sub-D|Manufacturer-specific signal designation||||Desi**g**nation|
|||||**p**lu**g** **(**IP65**)**|Festo field-|ABB CS**3**1|Moeller SUCONET K|||
||||||bus interface||Sub-D, 9-pin|DIN (round),<br>5-pin||
|||1<br>2<br>3<br>4<br>5<br>6<br>7<br>8<br>9<br>Hous-<br>ing|n.c.||||||Not connected|
||||n.c.||||||Not connected|
||||RxD/TxD-P|B|S+|Bus1|3 (TA/RA)|4 (TA/RA)|Received/transmitted<br>data P|
||||CNTR-P||||||Repeater control signal|
||||DGND||||||Data reference potential|
||||VP||||||Supply voltage|
||||n.c.||||||Not connected|
||||RxD/TxD-N|A|S-|Bus2|7 (TB/RB)|1 (TB/RB)|Received/transmitted<br>data N|
||||n.c.||||||Not connected|
|||||Cable clip|Screen|Screen|4 (screen)|Housing||
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
33
## CPI installation system
Accessories – Fieldbus node CP-FB05-E
|ing data|ing data|ing data|ing data|
|---|---|---|---|
|nation|||Part No.<br>Type|
|us node||||
||Fieldbus nodefor Festo fieldbus, ABB CS31, Moeller SUCONET K||18238<br>CP-FB05-E|
|||||
|r supply||||
||Power supply socket, straight M18x1, 4-pin|for 1.5 mm2<br>|18493<br>NTSD-GD-9<br><br>|
|||for 2.5 mm2|18526<br>NTSD-GD-13,5|
||Power supply socket, angled M18x1, 4-pin|for 1.5 mm2|18527<br>NTSD-WD-9|
|||for 2.5 mm2|533119<br>NTSD-WD-11|
|||||
|us connection||||
||Fieldbus socket, Sub-D connection||532216<br>FBS-Sub-9-GS-DP-B|
||M12 adapter||533118<br>FBA-2-M12-5POL-RK|
||Socket M12x1, 5-pin, straight,<br>for self-assembly of a connecting cable for FBA-2-M12-5POL-RK||1067905<br>NECU-M-B12G5-C2-PB|
||Plug M12x1, 5-pin, straight,<br>for self-assembly of a connecting cable for FBA-2-M12-5POL-RK||1066354<br>NECU-M-S-B12G5-C2-PB|
|||||
|terminal connection||||
||Connectin**g**cable WS-WD|0,25 m|540327<br>KVI-CP-3-WS-WD-0,25|
|||0,5 m|540328<br>KVI-CP-3-WS-WD-0,5|
|||2 m|540329<br>KVI-CP-3-WS-WD-2|
|||5 m|540330<br>KVI-CP-3-WS-WD-5|
|||8 m|540331<br>KVI-CP-3-WS-WD-8|
||Connectin**g**cable GS-GD|2 m|540332<br>KVI-CP-3-GS-GD-2|
|||5 m|540333<br>KVI-CP-3-GS-GD-5|
|||8 m|540334<br>KVI-CP-3-GS-GD-8|
|||||
|ting||||
||Mounting for H-rail||170169<br>CP-TS-HS35|
|||||
|documentation||||
||User documentation – Bus node CP-FB**5**-E|German|165105<br>P.BE-CP-FB5-E-DE|
|||English|165205<br>P.BE-CP-FB5-E-EN|
|||French|165135<br>P.BE-CP-FB5-E-FR|
|||Italian|165165<br>P.BE-CP-FB5-E-IT|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
34
## CPI installation system
Technical data – Fieldbus node CP-FB06-E
This fieldbus node handles communication between the decentralised CP system and a higher-order master. The fieldbus node is a slave station on the fieldbus and represents the I/O data and diagnostic information of the connected CP modules on the network.
For the electrical peripherals, this module provides the separate electrical system supply for
- the electronics modules and sensor supply, and
- the load current of the valves.
## Application
## Bus connection
The bus connection is established via two 9-pin M23 connections with a typical Interbus pin allocation. The plug and socket are labelled with Remote IN and Remote OUT in
accordance with the definition for the Interbus remote bus. Both bus cables are always routed to the fieldbus node and looped through in accordance with the ring structure of the Interbus.
The CP fieldbus node receives the data from the higher-order controller and forwards it to the connected CP valve terminals or electrical output modules. The signal status of the
inputs is requested from the input modules and forwarded to the CP fieldbus nodes.
## Implementation
The FB6 supports the digital input and output modules and the solenoid coils. It can service a total of 64 digital
outputs, of which max. 64 can include solenoid coils, and 64 digital inputs.
Note -HPlease observe the general guidelines regarding addressing when ~~a~~ assigning outputs.
Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
35
## CPI installation system
Technical data – Fieldbus node CP-FB06-E
|General technical data|General technical data|General technical data|
|---|---|---|
|Type||CP-FB06-E|
|Baud rates<br>[kbps]||500|
|ID code||3|
|No. of process data bits||16, 32, 48 or 64 depending on expansion|
|PCP channel||No|
|Configuration support||Icon file for CMD software<br>Station description file with CMD software|
|Max. no. of solenoid coils||64|
|Max. no. of outputs incl. solenoid coils||64|
|Max. no. of inputs||64|
|LED dia**g**nostic indicators|Power|Power supply indicator for internal electronics|
||Power V|Power supply indicator for valves|
||0…3|CP string LED|
||RC|Remotebus check|
||BA|Bus active|
||RD|Remotebus disable|
|Device-specific diagnostics transmitted to the controller as common<br>message (peripherals errors)||• Short circuit/overload of outputs<br>• Undervoltage of valves<br>• Undervoltage of outputs<br>• Undervoltage of sensor supply|
|Additional functions||Test routine for checking the valves and outputs without bus communication|
|O**p**eratin**g**volta**g**e|Nominal value<br>[V DC]|24 polarity-safe|
||Permissible range<br>[V DC]|20.4 … 26.4|
||Power failure buffering<br>[ms]|20|
|Current consum**p**tion**p**in 1|Fieldbus node<br>[mA]|250|
||CP modules<br>[mA]|560 (internal electronics) + total current consumption of inputs|
|Current limiting|Electronics of fieldbus node and<br>CP connection<br>[A]|Max. 1.25, short circuit proof|
|Load voltage pin 2|Solenoid valves|Total of all valves switched simultaneously, see technical data on CP valves<br>�Internet: type 10 and Internet: type 12<br>(Compact Performance valve terminals CPV and CPA)|
|Current limiting|Supply for solenoid valves<br>[A]|Max. 2.5, fused|
|Protection class to EN 60529||IP65|
|Tem**p**erature ran**g**e|Operation<br>[°C]|–5 … +50|
||Storage<br>[°C]|–20 … +70|
|Materials|Housing|Die-cast aluminium|
|Dimensions (LxWxD)|[mm]|196.4 x 88 x 61.5|
|Weight|[g]|915|
|Certifications|Certifications|
|---|---|
|Thisproduct is certified for operation in the EX range asper EU-ATEX guideline||
|ATEX category gas|II 3G|
|Ex-ignition protection type gas|Ex na II T5 X|
|ATEX category dust|II 3D|
|EX-ignition protection type dust|Ex tD A22 IP65 T80° C X|
|ATEX ambient temperature<br>[°C]|–5 ≤Ta ≤+50|
|Certification|c UL us recognized (OL)|
|CE mark (see declaration of conformity)|In accordance with EU explosionprotection directive (ATEX)|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
36
## CPI installation system
Technical data – Fieldbus node CP-FB06-E
**==> picture [489 x 232] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection and display components<br>1 2<br>6<br>3<br>5<br>1 Remote bus incoming<br>2 Remote bus outgoing<br>4 3 Voltage supply connection<br>4 String LEDs<br>5 Save key<br>6 Interbus-specific LEDs<br>**----- End of picture text -----**<br>
|Pin allocation f|or the INTERBUS interface, non-floating installation remote bus|or the INTERBUS interface, non-floating installation remote bus|or the INTERBUS interface, non-floating installation remote bus|or the INTERBUS interface, non-floating installation remote bus|
|---|---|---|---|---|
|Pin allocation||Pin No.1)|Signal|Designation|
|Incoming|||||
|Plug view||1<br>2<br>3<br>4<br>5<br>6<br>7<br>8<br>Sleeve|DO|Data out|
||||/DO|Data out inverse|
||||DI<br>/DI|Data in<br>Dt i i|
||||Load|aa n nverse<br>Reference conductor|
||||FE|Functional earthing for installation remote bus|
||||+24 V|Installation remote bus supply|
||||+0 V|Installation remote bus supply|
||||Screen|Screening|
||||||
|Outgoing|||||
|Socket view||1<br>2<br>3<br>4<br>5<br>6<br>7<br>8<br>9<br>Sleeve|DO|Data out|
||||/DO|Data out inverse|
||||DI|<br>Data in|
||||/DI|Data in inverse|
||||Load|Reference conductor|
||||FE|Functional earthing for installation remote bus|
||||+24 V|Installation remote bus supply|
||||+0 V|Installation remote bus supply|
||||RBST|Establish bridge to pin 5|
||||Screen|Screening|
1) Pins not listed here must not be connected.
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
37
## CPI installation system
Accessories – Fieldbus node CP-FB06-E
|ring data|ring data|||
|---|---|---|---|
|nation|||Part No.<br>Type|
|bus node||||
||Fieldbus node INTERBUS||18225<br>CP-FB06-E|
|||||
|r supply||||
||Power supply socket, straight M18x1, 4-pin|for 1.5 mm2<br>|18493<br>NTSD-GD-9<br><br>|
|||for 2.5 mm2|18526<br>NTSD-GD-13,5|
||Power supply socket, angled M18x1, 4-pin|for 1.5 mm2|18527<br>NTSD-WD-9|
|||for 2.5 mm2|533119<br>NTSD-WD-11|
|||||
|terminal connection||||
||Connectin**g**cable WS-WD|0,25 m|540327<br>KVI-CP-3-WS-WD-0,25|
|||0,5 m|540328<br>KVI-CP-3-WS-WD-0,5|
|||2 m|540329<br>KVI-CP-3-WS-WD-2|
|||5 m|540330<br>KVI-CP-3-WS-WD-5|
|||8 m|540331<br>KVI-CP-3-WS-WD-8|
||Connectin**g**cable GS-GD|2 m|540332<br>KVI-CP-3-GS-GD-2|
|||5 m|540333<br>KVI-CP-3-GS-GD-5|
|||8 m|540334<br>KVI-CP-3-GS-GD-8|
|||||
|ting||||
||Mounting for H-rail||170169<br>CP-TS-HS35|
|||||
|documentation||||
||User documentation – Bus node CP-FB06-E|German|165106<br>P.BE-CP-FB6-E-DE|
|||English|165206<br>P.BE-CP-FB6-E-EN|
|||French|165136<br>P.BE-CP-FB6-E-FR|
|||Italian|165166<br>P.BE-CP-FB6-E-IT|
|||Spanish|165236<br>P.BE-CP-FB6-E-ES|
|||Swedish|165266<br>P.BE-CP-FB6-E-SV|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
38
## CPI installation system
Technical data – Fieldbus node CP-FB11-E
This fieldbus node handles communication between the decentralised CP system and a higher-order master. The fieldbus node is a slave station on the fieldbus and represents the I/O data and diagnostic information of the connected CP modules on the network.
For the electrical peripherals, this module provides the separate electrical system supply for
- the electronics modules and sensor supply, and
• the load current of the valves. The FB11 fieldbus node supports the CAN-based fieldbus protocol DeviceNet.
- DeviceNet
## Application
Bus connection
The DeviceNet connection is estabtypically installed using main and lished via a 5-pin M12 plug with pins branch lines that are connected via that corresponds to the specific mini T-pieces. connector. A DeviceNet installation Various manufacturers such as Turck, with a higher degree of protection is Lumberg and Rockwell offer finished
cables and terminating resistors. The bus closed while a bus station is being terminating resistors are attached to removed. Provides detailed diagnostic the two outermost T-pieces. information about status bits for the This installation technique keeps the master controller.
~~eee~~ Implementation
Implementation The FB11 supports the digital input and output modules. It can service a total of 64 digital
inputs and 64 digital outputs, of which max. 64 can include solenoid coils.
Note -HPlease observe the general guidelines on I/O addressing when assigning the outputs.
Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
39
## CPI installation system
Technical data – Fieldbus node CP-FB11-E
|General technical data|General technical data|General technical data|
|---|---|---|
|Type||CP-FB11-E|
|Baud rates<br>[kbps]||Set using HW switch<br>• 125<br>• 250<br>• 500|
|Addressing range||Set using 2 rotary switches<br>0 … 63|
|Product type||Communication converter (12 dec.)|
|Product code||2282 hex./35050 dec.|
|Type of communication||Polling/Cos/Bit Strobe|
|Configuration support||EDS file and graphics symbol|
|Max. no. of solenoid coils||64|
|Max. no. of outputs and solenoid coils||64|
|Max. no. of inputs||64|
|LED dia**g**nostic indicators|Bus/Power|Operating voltage of bus|
||Module status|Operating status|
||I/O Error|Internal error|
|Device-specific diagnosis via DeviceNet||• Short circuit/overload of outputs<br>• Undervoltage of valves<br>• Undervoltage of outputs<br>• Undervoltage of sensor supply<br>• Interrupt point on CP string|
|O**p**eratin**g**volta**g**e|Nominal value<br>[V DC]|24 polarity-safe|
||Permissible range<br>[V DC]|20.4 … 26.4|
||Power failure buffering<br>[ms]|20|
|Current consum**p**tion**p**in 1|Fieldbus node<br>[mA]|250|
||CP module<br>[mA]|560 (internal electronics) + total current consumption of inputs, internal|
|Current limiting|Electronics of fieldbus node and<br>CP connection<br>[A]|Max. 1.25, short circuit proof|
|Current consumption pin 2|Solenoid valves|Total of all valves switched simultaneously, see technical data on CP valves<br>�Internet:type 10 and Internet: type 12<br>(Compact Performance valve terminals CPV and CPA)|
|Protection class to EN 60529||IP65|
|Tem**p**erature ran**g**e|Operation<br>[°C]|–5 … +50|
||Storage/transport<br>[°C]|–20 … +70|
|Materials|Housing|Die-cast aluminium|
|Dimensions (HxWxD)|[mm]|196.4 x 88 x 61.5|
|Grid dimension|[mm]|72|
|Weight|[g]|950|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
40
## CPI installation system
Technical data – Fieldbus node CP-FB11-E
|Certifications|Certifications|
|---|---|
|This product is certified for operation in the EX range as per EU-ATEX guideline||
|ATEX category gas|II 3G|
|Ex-ignition protection type gas|Ex na II T5 X|
|ATEX category dust|II 3D|
|EX-ignition protection type dust|Ex tD A22 IP65 T80° C X|
|ATEX ambient temperature<br>[°C]|–5 ≤Ta ≤+50|
|Certification|c UL us recognized (OL)|
|CE mark (see declaration of conformity)|In accordance with EU explosion protection directive (ATEX)|
**==> picture [489 x 235] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection and display components<br>1<br>6<br>2<br>3<br>5<br>1 Plug for fieldbus cable<br>2 Operating voltage connection for<br>CP and valves<br>4 3 Operating voltage LEDs<br>4 String LEDs<br>5 Save key<br>6 Bus status LEDs<br>**----- End of picture text -----**<br>
|Pin allocation for fieldbus interface|Pin allocation for fieldbus interface|Pin allocation for fieldbus interface||||
|---|---|---|---|---|---|
|Pin allocation||||Pin No.|Signal|
|**220** <br>|**F**<br>n|1<br>**2**<br>1 MΩ<br>3|1 Plug|1<br>|Screen<br>|
|||||2|+24 V bus|
|||||3|GND Bus|
|||||4|Data+|
|||||5|Data–|
||||2 Housing of the f|ieldbus connection module PE||
||||3 Internal screening connection in the valve terminal|||
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
41
## CPI installation system
Accessories – Fieldbus node CP-FB11-E
|ring data|ring data|||
|---|---|---|---|
|nation|||Part No.<br>Type|
|bus node||||
||Fieldbus node DeviceNet||18227<br>CP-FB11-E|
|||||
|r supply||||
||Power supply socket, straight M18x1, 4-pin|for 1.5 mm2|18493<br>NTSD-GD-9|
|||for 2.5 mm2|18526<br>NTSD-GD-13,5|
||Power supply socket, angled M18x1, 4-pin|for 1.5 mm2|18527<br>NTSD-WD-9|
|||for 2.5 mm2|533119<br>NTSD-WD-11|
|||||
|bus connection||||
||Bus connection, straight, PG9, 5-pin||18324<br>FBSD-GD-9-5POL|
|||||
|terminal connection||||
||Connectin**g**cable WS-WD|0,25 m|540327<br>KVI-CP-3-WS-WD-0,25|
|||0,5 m|540328<br>KVI-CP-3-WS-WD-0,5|
|||2 m|540329<br>KVI-CP-3-WS-WD-2|
|||5 m|540330<br>KVI-CP-3-WS-WD-5|
|||8 m|540331<br>KVI-CP-3-WS-WD-8|
||Connectin**g**cable GS-GD|2 m|540332<br>KVI-CP-3-GS-GD-2|
|||5 m|540333<br>KVI-CP-3-GS-GD-5|
|||8 m|540334<br>KVI-CP-3-GS-GD-8|
|||||
|ting||||
||Mounting, for H-rail||170169<br>CP-TS-HS35|
|||||
|documentation||||
||User documentation – Bus node CP-FB11-E|German|165111<br>P.BE-CP-FB11-E-DE|
|||English|165211<br>P.BE-CP-FB11-E-EN|
|||French|165141<br>P.BE-CP-FB11-E-FR|
|||Italian|165171<br>P.BE-CP-FB11-E-IT|
|||Spanish|165241<br>P.BE-CP-FB11-E-ES|
|||Swedish|165271<br>P.BE-CP-FB11-E-SV|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
42
## CPI installation system
Technical data – Fieldbus node CP-FB13-E
This fieldbus node handles communication between the decentralised CP system and a higher-order master via Profibus DP. The fieldbus node is a slave station on the fieldbus and represents the I/O data and diagnostic information of the connected CP modules on the network.
For the electrical peripherals, this module provides the separate electrical system supply for
- the electronics modules and sensor supply, and
- the load current of the valves.
The status of the voltage supplies and the bus communication is indicated via the LEDs Power, Power Valves, String Error and Bus Error.
- Profibus-DP
## Application
Bus connection
The bus connection is established via from other manufacturers) facilitates interface is designed for the control of a 9-pin Sub-D socket with a typical the connection of an incoming and an network components via a fibre optic -HNote Profibus allocation (to EN 50 170). outgoing bus cable. An active bus cable connection and provides Alternatively the bus connection can The bus connector plug (with protecterminal can be connected using the detailed diagnostic information for be established via a 2x M12 tion class IP65 from Festo or IP20 integrated DIL switch. The Sub-D master detection. adapter plug (B-coded).
~~eee~~ Implementation
The FB13 supports digital input and output modules and solenoid coils. 64 digital outputs in total, of which max. 64 solenoid coils. Max. 64 digital inputs for recording sensor signals.
Note -HWhen assigning the electrical modules, please observe the configuration guidelines for valve terminals in relation to address allocation and the number of occupied module positions.
Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
43
## CPI installation system
Technical data – Fieldbus node CP-FB13-E
|General technical data|General technical data|General technical data|
|---|---|---|
|Type||CP-FB13-E|
|Baud rates<br>[MBaud]||Automatic detection<br>0.0096 … 12|
|Addressing range||Set using 2 DIL switches<br>1 … 125|
|Product family||4: Valves|
|Ident. number||0xFB13|
|Type of communication||Cyclic communication|
|Configuration support||GSD file and bitmaps|
|Max. no. of solenoid coils||64|
|Max. no. of outputs and solenoid coils||64|
|Max. no. of inputs||64|
|LED dia**g**nostic indicators|Power|Operating voltage of electronics|
||Power V|Operating voltage of valves and outputs|
||Bus Error|Communication error|
||0…3|CP string|
|Device-specific diagnostics via Profibus-DP||• Short circuit/overload of outputs<br>• Undervoltage of valves<br>• Undervoltage of outputs<br>• Undervoltage of sensor supply<br>• Interrupt points on CP string|
|Additional functions||• Test routine for checking the valves and outputs without bus communication|
|O**p**eratin**g**volta**g**e|Nominal value<br>[V DC]|24 polarity-safe|
||Permissible range<br>[V DC]|20.4 … 26.4|
||Power failure buffering<br>[ms]|20|
|Current consum**p**tion**p**in 1|Fieldbus node<br>[mA]|250|
||CP module<br>[mA]|560 (internal electronics) + total current consumption of inputs, internal|
|Current limiting|Electronics of fieldbus node and<br>CP connection<br>[A]|Max. 1.25, short circuit proof|
|Current consumption pin 2|Solenoid valves|Total of all valves switched simultaneously, see technical data on CP valves<br>�Internet: type 10 and Internet: type 12<br>(Compact Performance valve terminals CPV and CPA)|
|Current limiting|Supply for solenoid valves<br>[A]|Max. 2.5, fused|
|Protection class to EN 60529||IP65|
|Tem**p**erature ran**g**e|Operation<br>[°C]|–5 … +50|
||Storage/transport<br>[°C]|–20 … +70|
|Materials|Housing|Die-cast aluminium|
|Dimensions (LxWxD)|[mm]|196.4 x 88 x 61.5|
|Grid dimension|[mm]|72|
|Weight|[g]|925|
|Certifications|Certifications|
|---|---|
|This product is certified for operation in the EX range as per EU-ATEX guideline||
|ATEX category gas|II 3G|
|Ex-ignition protection type gas|Ex na II T5 X|
|ATEX category dust|II 3D|
|EX-ignition protection type dust|Ex tD A22 IP65 T80° C X|
|ATEX ambient temperature<br>[°C]|–5 ≤Ta ≤+50|
|Certification|c UL us recognized (OL)|
|CE mark (see declaration of conformity)|In accordance with EU explosion protection directive (ATEX)|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
44
## CPI installation system
Technical data – Fieldbus node CP-FB13-E
**==> picture [489 x 217] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection and display components<br>1<br>6<br>2<br>3<br>5<br>1 Plug for fieldbus cable<br>2 Operating voltage connection for<br>CP and valves<br>4 3 Operating voltage LEDs<br>4 String LEDs<br>**----- End of picture text -----**<br>
- 1 Plug for fieldbus cable 2 Operating voltage connection for CP and valves
- 3 Operating voltage LEDs 4 String LEDs 5 Save key 6 Bus-specific LED
|Pin allocation for Profibu|s DP interface||||
|---|---|---|---|---|
|Pin allocation||Pin|Signal|Designation|
|Plug, Sub-D|||||
|||1|n.c.|Not connected|
|||2|n.c.|Not connected|
|||3|RxD/TxD-P|Received/transmitted data P|
|||4|CNTR-P1)|Repeater control signal|
|||5|DGND|Data reference potential (M5V)|
|||6|VP|Supply voltage (P5V)|
|||7|n.c.|Not connected|
|||8|RxD/TxD-N|Received/transmitted data N|
|||9|n.c.|Not connected|
|||Hous-<br>ing|Screen|Connection to housing|
||||||
|Bus connection M12 ada|pter plug (B-coded)||||
|Incoming||1|n.c.|Not connected|
|||2|RxD/TxD-N|Received/transmitted data N|
|||3|n.c.|Not connected|
|||4|RxD/TxD-P|Received/transmitted data P|
|||5 and<br>M12|Screen|Connection to functional earth|
||||||
|Outgoing||1|VP|Supply voltage (P5V)|
|||2|RxD/TxD-N|Received/transmitted data N|
|||3|DGND|Data reference potential (M5V)|
|||4|RxD/TxD-P|Received/transmitted data P|
|||5 and<br>M12|Screen|Connection to functional earth|
1) The repeater control signal CNTR-P is realised as a TTL signal.
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
45
## CPI installation system
Accessories – Fieldbus node CP-FB13-E
|ing data|ing data|||
|---|---|---|---|
|nation|||Part No.<br>Type|
|bus node||||
||Fieldbus nodefor PROFIBUS-DP||174337<br>CP-FB13-E|
|||||
|r supply||||
||Power supply socket, straight M18x1, 4-pin|for 1.5 mm2<br>|18493<br>NTSD-GD-9<br><br>|
|||for 2.5 mm2|18526<br>NTSD-GD-13,5|
||Power supply socket, angled M18x1, 4-pin|for 1.5 mm2|18527<br>NTSD-WD-9|
|||for 2.5 mm2|533119<br>NTSD-WD-11|
|||||
|bus connection||||
||Plug Sub-D, for Profibus DP||532216<br>FBS-SUB-9-GS-DP-B|
||Bus connection 2x M12 adapter plug (B-coded) for Profibus DP||533118<br>FBA-2-M12-5POL-RK|
||Socket M12x1, 5-pin, straight,<br>for self-assembly of a connecting cable for FBA-2-M12-5POL-RK||1067905<br>NECU-M-B12G5-C2-PB|
||Plug M12x1, 5-pin, straight,<br>for self-assembly of a connecting cable for FBA-2-M12-5POL-RK||1066354<br>NECU-M-S-B12G5-C2-PB|
|||||
|terminal connection||||
||Connectin**g**cable WS-WD|0,25 m|540327<br>KVI-CP-3-WS-WD-0,25|
|||0,5 m|540328<br>KVI-CP-3-WS-WD-0,5|
|||2 m|540329<br>KVI-CP-3-WS-WD-2|
|||5 m|540330<br>KVI-CP-3-WS-WD-5|
|||8 m|540331<br>KVI-CP-3-WS-WD-8|
||Connectin**g**cable GS-GD|2 m|540332<br>KVI-CP-3-GS-GD-2|
|||5 m|540333<br>KVI-CP-3-GS-GD-5|
|||8 m|540334<br>KVI-CP-3-GS-GD-8|
|||||
|ting||||
||Mounting for H-rail||170169<br>CP-TS-HS35|
|||||
|documentation||||
||User documentation – Bus node CP-FB1**3**-E|German|165113<br>P.BE-CP-FB13-E-DE|
|||English|165213<br>P.BE-CP-FB13-E-EN|
|||French|165143<br>P.BE-CP-FB13-E-FR|
|||Italian|165173<br>P.BE-CP-FB13-E-IT|
|||Swedish|165273<br>P.BE-CP-FB13-E-SV|
|||Spanish|165243<br>P.BE-CP-FB13-E-ES|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
46
## CPI installation system
Technical data – Input modules CP-E16
## Function
Digital input modules facilitate the connection of proximity sensors or other 24 V DC sensors (inductive, capacitive, etc.).
M12 plugs with double allocation are separated using a DUO plug or DUO cable.
Application
- Input modules for 24 V DC sensor signals
- M8 and M12 plugs, single allocation connection technology with 16 connections, double allocation connection technology with 8 connections
- M12 plug, 5-pin
- The input statuses are indicated for each input signal on an assigned LED
- 24 V DC supply provided for all connected sensors
- Diagnostic LED for short circuit/ undervoltage of sensor supply
- Diagnostic LED for short circuit/ interruption of external sensor supply with CP-E-16-M8-Z
General technical data Type CP-E16-M8 CP-E16N-M8 CP-E16-M12x2-5POL positive switching negative switching positive switching ~~a~~ No. of inputs 16 ~~a~~ Allocation of inputs Single allocation Double allocation Sensor connection type 16x M8, 3-pin 8x M12, 5-pin ~~a~~ Power supply 24 V DC Coming from bus node ~~a~~ Intrinsic current consumption of electronics [mA] 40 90 ~~a~~ Input current at 24 V DC (from sensor) [mA] Typically 8 Typically 6 ~~a~~ Fuse protection for sensors and electronic module Internal electronic short circuit protection ~~a~~ Max. current consumption of sensor supply, residual current [A] Max. 0.5 ~~a~~ Supply voltage of sensors [V] 24 DC ±25% ~~a~~ Protection against polarity reversal For logic and sensor voltage ~~a~~ Galvanic isolation None Switchin **g** level Signal 0 [V] ≤5 ≥–11 ≤6 ~~eee~~ Signal 1 [V] ~~es~~ ≥11 ≤–5 ≥8.6 ~~Po~~ Input delay [ms] Typically 5 Typically 3 ~~Pn~~ Switching logic PNP NPN PNP ~~a~~ Input characteristic curve To IEC 1131-2 ~~a~~ Connection to bus node Via pre-assembled cables ~~a~~ Protection class to EN 60529 IP65 (when fully plugged in or fitted with protective cover) Tem **p** erature ran **g** e Operation [°C] –5 … +50 ~~Ee~~ Storage [°C] ~~PO~~ –20 … +70 ~~a~~ Material Die-cast aluminium ~~a~~ Dimensions [mm] 148.9 x 66 x 47.9 140.9 x 78 x 55.2 Weight [g] 400 500
Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
47
## CPI installation system
Technical data – Input modules CP-E16
|General technical data|General technical data|General technical data|General technical data|General technical data|
|---|---|---|---|---|
|Type||CP-E16N-M12x2<br>negative switching|CP-E16-M8-Z<br>positive and negative switching||
|No. of inputs||16|||
|Allocation of inputs||Double allocation|Single allocation||
|Sensor connection type||8x M12, 4-pin|16x M8, 3-pin||
|Power supply 24 V DC||Coming from bus node|Coming from bus node, connection for<br>additional sensor supply||
|Intrinsic current consumption of electronics<br>[mA]||90|40||
|Input current at 24 V DC (from sensor)<br>[mA]||Typically 8|||
|Fuse protection for sensors and electronic module||Internal electronic short circuit<br>protection|Electronic short circuit protection per<br>group||
|Max. current consumption of sensor supply, residual current<br>[A]||Max. 0.5|Max. 1 per 8-fold input group||
|Supply voltage of sensors|[V]|24 DC ±25%|||
|Protection against polarity reversal||For logic and sensor voltage|||
|Galvanic isolation||None|||
|Switchin**g**level|||PNP|NPN|
||Signal 0<br>[V]|≥11|≤6|≥–8.6|
||Signal 1<br>[V]|≤5|≥8.6|≤–6|
|Input delay|[ms]|Typically 5|Typically 3||
|Switching logic||NPN|PNP/NPN||
|Input characteristic curve||To IEC 1131-2|||
|Connection to bus node||Via pre-assembled cables|||
|Protection class to EN 60529||IP65 (when fully plugged in or fitted with protective cover)|||
|Tem**p**erature ran**g**e|Operation<br>[°C]|–5 … +50|||
||Storage<br>[°C]|–20 … +70|||
|Material||Die-cast aluminium|||
|Material note||Conforms to RoHS|||
|Dimensions|[mm]|140.9 x 78 x 55.2|216.9 x 66 x 50.6||
|Weight|[g]|500|420||
|Certifications||
|---|---|
|This product is certified for operation in the EX range as per EU-ATEX guideline||
|ATEX category gas|II 3G|
|Ex-ignition protection type gas|Ex na II T5 X|
|ATEX category dust|II 3D|
|EX-ignition protection type dust|Ex tD A22 IP65 T80° C X|
|ATEX ambient temperature<br>[°C]|–5 ≤Ta ≤+50|
|Certification|c UL us recognized (OL)|
|CE mark1) **(**see declaration of conformit**y)**|To EU-Ex-RL (ATEX)|
||To EU-EMV-RL|
1) Certification not valid for: CP-E16N-M8 and CP-E16N-M12
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
48
## CPI installation system
Technical data – Input modules CP-E16
**==> picture [489 x 192] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection and display components<br>CP-E16-M12x2-5POL and CP-E16N-M12x2<br>3<br>1<br>4<br>2 1 CP connection<br>2 Slot for inscription labels<br>5 (ISB 6x10)<br>3 Identification of input type:<br>-INPUT-P for PNP inputs<br>-INPUT-N for NPN inputs<br>4 Status LED (green)<br>5 Sensor connections<br>6 Green LED for status display (one<br>6 LED per input)<br>**----- End of picture text -----**<br>
|Pin allocation for se|nsor connections CP-E16-M12x2-5Pol|nsor connections CP-E16-M12x2-5Pol|nsor connections CP-E16-M12x2-5Pol|nsor connections CP-E16-M12x2-5Pol|nsor connections CP-E16-M12x2-5Pol|nsor connections CP-E16-M12x2-5Pol|
|---|---|---|---|---|---|---|
|Pin allocation||Pin|Signal|Description|Pin|Signal|
|||1<br>2<br>3<br>4<br>5|24 V<br>Ix+1*|Operating voltage 24 V<br>Sensor signal|1<br>2|24 V<br>Ix+3*|
||||0 V|Operating voltage 0 V|3|0 V|
||||Ix*|Sensor signal|4|Ix+2*|
||||Ground|Earth terminal|5|Ground|
|Pin allocation for sensor connections CP-E16…-M12x2|Pin allocation for sensor connections CP-E16…-M12x2|Pin allocation for sensor connections CP-E16…-M12x2|Pin allocation for sensor connections CP-E16…-M12x2|Pin allocation for sensor connections CP-E16…-M12x2|Pin allocation for sensor connections CP-E16…-M12x2|Pin allocation for sensor connections CP-E16…-M12x2|
|---|---|---|---|---|---|---|
|Pin allocation||Pin|Signal|Description|Pin|Signal|
|||1<br>2<br>3<br>4|24 V<br>Ix+1*|Operating voltage 24 V<br>Sensor signal|1<br>2|24 V<br>Ix+3*|
||||0 V|<br>Oeratin voltae 0 V|3|0 V|
||||<br>Ix*|pg g<br>Sensor signal|4|<br>Ix+2*|
* Ix = Input x
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
49
## CPI installation system
Technical data – Input modules CP-E16
**==> picture [488 x 269] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection and display components<br>CP-E16-M8-Z<br>1 4<br>2<br>5<br>3<br>1 CP connection<br>2 Status LED (green)<br>6<br>3 Slot for inscription labels<br>(ISB 6x10)<br>4 Connection for sensor supply<br>5 Red LED for short circuit display<br>or sensor voltage failure (one LED<br>per input group)<br>6 Sensor connections<br>7 Green LED for status display (one<br>7 LED per input)<br>**----- End of picture text -----**<br>
|cation for external sensor supply CP-E16-M8-Z|cation for external sensor supply CP-E16-M8-Z|cation for external sensor supply CP-E16-M8-Z|cation for external sensor supply CP-E16-M8-Z|cation for external sensor supply CP-E16-M8-Z|
|---|---|---|---|---|
|cation|Pin|Signal|Description||
||1<br>2<br>3<br>4<br>5|24 V DC ±25%|Operating voltage|-H-<br>Note<br>|
|||PNP/NPN|Coding with negative/positive switching:<br>– PNP operation (pin 2 and 3 bridged)<br>– NPN operation (pin 2 and 1 bridged)|External sensor supply for<br>CP-E16-M8-Z:<br>Specified for PNP or NPN operation<br>**(type** **CP-E16-M8-Z).**|
|||0 V|Operating voltage 0 V|The input module provides PNP or<br>NPN inputs. The setting for PNP or<br><br><br><br><br><br>|
|||n.c.|Not connected|**NPN**<br>**i**<br>**i**<br>**d** **b** **i**<br>**lli**<br>operat on s ma e y nsta ng<br>a bridge in the socket of the sensor<br>**supply** **connection.**|
|||Ground|Earth terminal||
## Pin allocation for sensor connections CP-E16…-M8 and CP-E16-M8-Z
|cation for sensor connections CP-E16…-M8 and CP-E16-M8-Z|cation for sensor connections CP-E16…-M8 and CP-E16-M8-Z|cation for sensor connections CP-E16…-M8 and CP-E16-M8-Z|cation for sensor connections CP-E16…-M8 and CP-E16-M8-Z|cation for sensor connections CP-E16…-M8 and CP-E16-M8-Z|cation for sensor connections CP-E16…-M8 and CP-E16-M8-Z|
|---|---|---|---|---|---|
|cation|Pin|Signal|Description|Pin|Signal|
||1<br>3<br>4|24 V|Operating voltage 24 V|1|24 V|
|||0 V|Operating voltage 0 V|3|0 V|
|||Ix*|Sensor signal|4|Ix+1*|
* Ix = Input x
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
50
## CPI installation system
Technical data – Input modules CP-E16
**==> picture [489 x 194] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection and display components<br>CP-E16-M8 and CP-E16N-M8<br>1<br>3<br>2<br>4<br>1 CP connection<br>2 Slot for inscription labels<br>(ISB 6x10)<br>3 Status LED (green)<br>4 Sensor connections<br>5 Green LED for status display (one<br>5 LED per input)<br>**----- End of picture text -----**<br>
|Pin allocation for sensor connections CP-E16…-M8 and CP-E16-M8-Z|Pin allocation for sensor connections CP-E16…-M8 and CP-E16-M8-Z|Pin allocation for sensor connections CP-E16…-M8 and CP-E16-M8-Z|Pin allocation for sensor connections CP-E16…-M8 and CP-E16-M8-Z|Pin allocation for sensor connections CP-E16…-M8 and CP-E16-M8-Z|Pin allocation for sensor connections CP-E16…-M8 and CP-E16-M8-Z|
|---|---|---|---|---|---|
|Pin allocation|Pin|Signal|Description|Pin|Signal|
||1|24 V|Operating voltage 24 V|1|24 V|
||3|0 V|Operating voltage 0 V|3|0 V|
||4|Ix*|Sensor signal|4|Ix+1*|
* Ix = Input x
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
51
## CPI installation system
Accessories – Input modules CP-E16
|ng data||||
|---|---|---|---|
|ation|||Part No.<br>Type|
|modules||||
||positive switching<br>negative switching||18205<br>CP-E16-M8<br>18243<br>CP-E16N-M8|
||<br>positive switching||175561<br>CP-E16-M12x2-5POL|
||negative switching||18244<br>CP-E16N-M12x2|
||positive and negative switching||189670<br>CP-E16-M8-Z|
|||||
|supply||||
||Power supply socket, straight, M12x1, 5-pin||18324<br>FBSD-GD-9-5POL|
|||||
|plugs||||
||Plu**g,**strai**g**ht socket**,**M12|5-pin, PG7<br>|175487<br>SEA-M12-5GS-PG7<br><br>|
|||4-pin, PG7|18666<br>SEA-GS-7|
|||4-pin, 2.5 mm2 O.D.|192008<br>SEA-4GS-7-2,5|
||Plu**g,**strai**g**ht**,**M8|3-pin, solderable|18696<br>SEA-GS-M8|
|||3-pin, screw-in|192009<br>SEA-3GS-M8-S|
||Plug for 2 sensor cables, M12, PG11|4-pin<br>|18779<br>SEA-GS-11-DUO<br><br>|
|||5-pin|192010<br>SEA-5GS-11-DUO|
|||||
|cables||<br><br>||
||Connectin**g**cable**,**M12**,**4-**p**in**,**strai**g**ht**p**lu**g**-strai**g**ht<br>socket|2.5 m|18684<br>KM12-M12-GSGD-2,5|
|||5.0 m|18686<br>KM12-M12-GSGD-5|
||Connecting cable, M12, 4-pin, straight plug-angled<br>socket|1.0 m|185499<br>KM12 M12-GSWD-1-4|
||Connectin**g**cable**,**M8**,**strai**g**ht**p**lu**g**-strai**g**ht socket|0.5 m|175488<br>KM8-M8-GSGD-0,5|
|||1.0 m|175489<br>KM8-M8-GSGD-1|
|||2.5 m|165610<br>KM8-M8-GSGD-2,5|
|||5.0 m|165611<br>KM8-M8-GSGD-5|
|||||
|ing||||
||Mounting for H-rail||170169<br>CP-TS-HS35|
|||||
|ocumentation||||
||User documentation for in**p**ut**/**out**p**ut modules|German|165125<br>P.BE.-CPEA-DE|
|||English|165225<br>P.BE.-CPEA-EN|
|||French|165127<br>P.BE.-CPEA-FR|
|||Italian|165157<br>P.BE.-CPEA-IT|
|||Spanish|165227<br>P.BE.-CPEA-ES|
|||Swedish|165257<br>P.BE.-CPEA-SV|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
52
## CPI installation system
Technical data – Input modules CP-E…-EL
Application
## Function
- Input modules for 24 V DC sensor signals
Digital input modules facilitate the connection of proximity sensors or other 24 V DC sensors (inductive, capacitive, etc.).
- M8 and M12 connection technology
- capacitive, etc.). • Display of the input statuses for Plugs with double allocation are each input signal via an assigned separated using a DUO plug or DUO LED cable. • Operating voltage supply 24 V DC for all connected sensors
- Diagnostic LED for short circuit/ overload of sensor supply
- Circumferential labelling with large, hinged inscription label
- Earthing plate and H-rail mounting already integrated
General technical data Type CP-E16-M12-EL CP-E16-M8-EL CP-E32-M8-EL positive switching positive switching positive switching ~~a~~ No. of inputs 16 32 ~~a~~ Allocation of inputs Double allocation Single allocation Double allocation ~~a~~ Sensor connection type 8x M12, 5-pin 16x M8, 3-pin 16x M8, 4-pin ~~CO~~ Power supply 24 V DC Via CP connection ~~CO~~ Intrinsic current consumption at operating voltage [mA] Typically 75 mA ~~a~~ Fuse (short circuit) Internal electronic fuse protection for each group Internal electronic fuse ~~a~~ Max. residual current per module [A] 0.7 1.4 ~~CO~~ Nominal operating voltage for sensors 24 ~~a~~ Operating voltage range for sensors [V] 18 … 30 DC ~~CO~~ Galvanic isolation None Switchin **g** level Signal 0 [V] ~~PO~~ ≤ 6 Signal 1 [V] ~~PO~~ ≥ 8.6 ~~CO~~ Debounce time at inputs [ms] 3 ms (0.5 ms, 10 ms, 20 ms, parameterisable) ~~CO~~ Signal extension 0.5 ms (15 ms, 50 ms, 100 ms, parameterisable) ~~CO~~ Switching logic PNP ~~a~~ Input characteristic curve To IEC 1131-2 Connection to bus node Via pre-assembled cables ~~CO~~ Dia **g** nostics ~~PO~~ CP communication ~~PO~~ Short circuit/overload ~~PO~~ Undervoltage LEDs 2 Module diagnostics 2 Module diagnostics 4 Group diagnostics 32 Channel status 16 Channel status
Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
53
## CPI installation system
Technical data – Input modules CP-E…-EL
|General technical data|||||
|---|---|---|---|---|
|Type||CP-E16-M12-EL<br>positive switching|CP-E16-M8-EL<br>positive switching|CP-E32-M8-EL<br>positive switching|
|Dimensions (LxWxH)|[mm]|143 x 104 x 30|||
|Weight|[g]|260|||
||||||
|Operating conditions|||||
|Type||CP-E16-M12-EL|CP-E16-M8-EL|CP-E32-M8-EL|
|Protection class to EN 60529||IP65 (when fully plugged in or fitted with protective cover)|||
|Ambient tem**p**erature|Operation<br>[°C]|–5 … +50|||
||Storage<br>[°C]|–20 … +70|||
|Corrosion resistance class CRC1)||1|||
|Certification||cULus listed (OL)|||
|Certification C-Tick||C-Tick Declaration of Conformity CT 19823|||
|CE mark (see declaration of conformity)||In accordance with EU EMC directive|||
||||||
1) Corrosion resistance class 1 to Festo standard 940 070 Components requiring low corrosion resistance. Transport and storage protection. Parts that do not have primarily decorative surface requirements, e.g. in internal areas that are not visible or behind covers.
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
54
## CPI installation system
Technical data – Input modules CP-E…-EL
**==> picture [489 x 196] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection and display components<br>CP-E16-M12-EL<br>4 5 6 7<br>3<br>2<br>7<br>1 CP connection, outgoing 6 Status LED (group) for short<br>1<br>8 2 CP connection, incoming circuit/overload of sensor<br>3 Status LED (module) for short supply (red)<br>circuit/overload of sensor 7 Fixture for inscription label<br>supply (red) holder ASCF-H-E2<br>4 Status LED for CP 8 Sensor connections<br>communication (green) (2 inputs per socket)<br>5 Status LEDs for inputs (status<br>7 7 display, green)<br>**----- End of picture text -----**<br>
|Pin allocation for s|Pin allocation for s|ensor connections CP-E16-M12-EL|ensor connections CP-E16-M12-EL||||
|---|---|---|---|---|---|---|
|Pin allocation||||Pin|Signal|Description|
|||||1|24 V|Operating voltage 24 V|
||||||||
|||||2|Ix+1*|Sensor signal|
|||||3|0 V|Operating voltage 0 V|
||||||||
|||||4|Ix*|Sensor signal|
|||||5|Ground|Earth terminal|
* Ix = Input x
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
55
## CPI installation system
Technical data – Input modules CP-E…-EL
|Connection and display components|Connection and display components|Connection and display components|Connection and display components|Connection and display components|||||||
|---|---|---|---|---|---|---|---|---|---|---|
|CP-E16-M8-EL|||||||||||
|||||||||1 CP connection, outgoing<br>2 CP connection, incoming<br>3 Status LED (module) for short<br>circuit/overload of sensor<br>supply (red)<br>4 Status LED for CP<br>communication (green)<br>5 Status LEDs for inputs (status<br>display, green)<br>6 Status LED (group) for short<br>circuit/overload of sensor<br>supply (red)<br>7 Fixture for inscription label<br>holder ASCF-H-E2<br>8 Sensor connections<br>(1 input per socket)|||
|2<br>3|4||5<br>6|7|||8||||
||||||||||||
|1|||||||||||
||||||||||||
||7|7|||||||||
||||||||||||
|Pin allocation fo|r sensor connections CP-E16-M8-EL||||||||||
|Pin allocation||||||||Pin|Signal|Description|
|||||||||1|24 V|Operating voltage 24 V|
||||||||||||
|||||||||3|0 V|Operating voltage 0 V|
||||||||||||
|||||||||4|Ix*|Sensor signal|
* Ix = Input x
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
56
## CPI installation system
Technical data – Input modules CP-E…-EL
- Connection and display components CP-E32-M8-EL 4 5 6
- 3 2 1 7 1 CP connection, outgoing 5 Status LEDs for inputs (status 2 CP connection, incoming display, green) 3 Status LED (module) for short 6 Fixture for inscription label circuit/overload of sensor holder ASCF-H-E2 supply (red) 7 Sensor connections
- 4 Status LED for CP communica(2 inputs per socket)
- 6 6 tion (green)
|Pin allocation for sensor connections CP-E32-M8-EL|Pin allocation for sensor connections CP-E32-M8-EL|Pin allocation for sensor connections CP-E32-M8-EL||||
|---|---|---|---|---|---|
|Pin allocation|||Pin|Signal|Description|
||||1|24 V|Operating voltage 24 V|
|||||||
||||2|Ix+1*|Sensor signal|
|||||||
||||3|0 V|Operating voltage 0 V|
||||4|Ix*|Sensor signal|
* Ix = Input x
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
57
## CPI installation system
Accessories – Input modules CP-E…-EL
|ng data||||
|---|---|---|---|
|ation|||Part No.<br>Type|
|modules||||
||positive switching||546923<br>CP-E16-M12-EL|
||positive switching||546922<br>CP-E16-M8-EL|
||positive switching||546921<br>CP-E32-M8-EL|
|||||
|onnectors||||
||Strai**g**ht**p**lu**g,**M12|5-pin, PG7<br>|175487<br>SEA-M12-5GS-PG7<br><br>|
|||4-pin, PG7|18666<br>SEA-GS-7|
|||4-pin, 2.5 mm2 O.D.|192008<br>SEA-4GS-7-2,5|
||Strai**g**ht**p**lu**g,**M8|3-pin, solderable|18696<br>SEA-GS-M8|
|||3-pin, screw-in|192009<br>SEA-3GS-M8-S|
||Plug for 2 cables, M12, PG11|4-pin<br>|18779<br>SEA-GS-11-DUO<br><br>|
|||5-pin|192010<br>SEA-5GS-11-DUO|
||Push-in T-connector|2x socket M8, 3-pin<br>1x plug M8, 4-pin|544391<br>NEDU-M8D3-M8T4|
||Push-in T-connector|2x socket M12, 5-pin<br>1x plug M12, 4-pin|541596<br>NEDU-M12D5-M12T4|
|||||
|cting cables||||
||DUO cable**,**1x strai**g**ht**p**lu**g**M12<br>|2x straight socket M8|18685<br>KM12-DUO-M8-GDGD|
|||1x straight socket M8 and<br>1x angled socket M8|18688<br>KM12-DUO-M8-GDWD|
|||2x angled socket M8<br>|18687<br>KM12-DUO-M8-WDWD<br><br>1)|
||Connectin**g**cable**,**M12**,**4-**p**in**,**strai**g**ht**p**lu**g**-strai**g**ht<br>socket|2.5 m|539052<br>NEBU-M12G4-K-2.5-M12G4|
|||5.0 m|539052<br>NEBU-M12G4-K-5-M12G41)|
||Connectin**g**cable**,**M8**,** **3**-**p**in**,**strai**g**ht**p**lu**g**-strai**g**ht<br>socket|0.5 m|539052<br>NEBU-M8G3-K-0.5-M8G31)|
|||1 m|539052<br>NEBU-M8G3-K-1-M8G31)|
|||2.5 m|539052<br>NEBU-M8G3-K-2.5-M8G31)|
|||5 m|539052<br>NEBU-M8G3-K-5-M8G31)|
|||||
|tion label holders||||
||Inscription label holders for EL modules, bag of 10||547473<br>ASCF-H-E2|
|||||
|ocumentation||||
||User documentation for in**p**ut**/**out**p**ut modules|German|539299<br>P.BE.-CPEA-CL-DE|
|||English|539300<br>P.BE.-CPEA-CL-EN|
|||French|539302<br>P.BE.-CPEA-CL-FR|
|||Italian|539303<br>P.BE.-CPEA-CL-IT|
|||Spanish|539301<br>P.BE.-CPEA-CL-ES|
|||Swedish|539304<br>P.BE.-CPEA-CL-SV|
1) Modular product, further information � Internet: nebu
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
58
## CPI installation system
Technical data – Input modules CP-E…-CL
## Function
Digital input modules facilitate the connection of proximity sensors or other 24 V DC sensors (inductive, capacitive, etc.).
Application
- Input modules for 24 V DC sensor signals
- M8 and M12 plug connection technology
- Plugs with double allocation are • M12 input module, inputs with separated using a DUO plug or DUO double allocation. M8 inputs with cable. single allocation
- M12 plug, 5-pin
- The input statuses are indicated for each input signal on an assigned LED
- 24 V DC supply provided for all connected sensors
- Diagnostic LED for short circuit/ undervoltage of sensor supply
- Modules support the CPI functionality (only in combination with the CPX CP interface)
|General technical data<br>Type<br>CP-E08-M12-CL<br>positive switching<br>CP-E08-M8-CL<br>positive switching<br>CP-E16-KL-CL<br>positive switching|General technical data<br>Type<br>CP-E08-M12-CL<br>positive switching<br>CP-E08-M8-CL<br>positive switching<br>CP-E16-KL-CL<br>positive switching|General technical data<br>Type<br>CP-E08-M12-CL<br>positive switching<br>CP-E08-M8-CL<br>positive switching<br>CP-E16-KL-CL<br>positive switching|General technical data<br>Type<br>CP-E08-M12-CL<br>positive switching<br>CP-E08-M8-CL<br>positive switching<br>CP-E16-KL-CL<br>positive switching|
|---|---|---|---|
|No. of inputs|8||16|
|Allocation of inputs|Double allocation|Single allocation||
|Sensor connection type|4x M12, 5-pin|8x M8, 3-pin|Spring-loaded terminals<br>or screw terminals|
|Power supply 24 V DC|From the bus node, basic unit, CP interface, etc.|||
|Intrinsic current consumption of electronics<br>[mA]|Typically 35 (inputs not connected)|||
|Input current at 24 V DC (from sensor)<br>[mA]|Typically 6|||
|Fuse protection for sensors and electronic module|Internal electronic short circuit protection|||
|Max. current consumption of sensor supply, residual current<br>[A]|Max. 0.8|||
|Nominal operating voltage for sensors|24|||
|Operating voltage range for sensors<br>[V DC]|18 … 30|||
|Protection against polarity reversal|For logic and sensor supply|||
|Galvanic isolation|None|||
|Switchin**g**level<br>Signal 0<br>[V]<br>Signal 1<br>[V]|≤5|||
||≥–11|||
|Input delay<br>[ms]|Typically 3|||
|Switching logic|PNP|||
|Input characteristic curve|To IEC 1131-2|||
|Connection to bus node|Via pre-assembled cables|||
|Dia**g**nostics|Undervoltage|||
||Short circuit/overload of sensor supply|||
Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
59
## CPI installation system
Technical data – Input modules CP-E…-CL
|General technical data|General technical data|General technical data|General technical data|
|---|---|---|---|
|Type|CP-E08-M12-CL<br>positive switching|CP-E08-M8-CL<br>positive switching|CP-E16-KL-CL<br>positive switching|
|Material|Polybutylene terephthalate|||
|Material note|Conforms to RoHS|||
|Dimensions (WxLxH)<br>[mm]|151 x 30 x 25|||
|Weight<br>[g]|165|190|145|
|Operating conditions|||||
|---|---|---|---|---|
|Type||CP-E08-M12-CL|CP-E08-M8-CL|CP-E16-KL-CL|
|Protection class to EN 60529||IP65/IP67 (when fully plugged in or fitted with<br>protective cap)||IP20|
|Ambient tem**p**erature|Operation<br>[°C]|–5 … +50|||
||Storage<br>[°C]|–20 … +70|||
|Corrosion resistance class CRC1)||1|||
> 1) Corrosion resistance class 1 to Festo standard 940 070
Components requiring low corrosion resistance. Transport and storage protection. Parts that do not have primarily decorative surface requirements, e.g. in internal areas that are not visible or behind covers.
|Certifications|Certifications|Certifications|Certifications|
|---|---|---|---|
|Type|CP-E08-M12-CL|CP-E08-M8-CL|CP-E16-KL-CL|
|ATEX category gas|II 3G||–|
|Ex-ignition protection type gas|Ex na II T5 X||–|
|ATEX category dust|II 3D||–|
|EX-ignition protection type dust|Ex tD A22 IP65 T80° C X||–|
|ATEX ambient temperature<br>[°C]|–5 ≤Ta ≤+50||–|
|Certification|c UL us recognized (OL)|||
|CE mark (see declaration of conformity)|In accordance with EU explosion protection directive (ATEX)|||
## Note -H-
If device combinations are operated ture of the individual devices deterin potentially explosive areas, the lomine the possible use of the comwest common zone, the temperature plete module. class as well as the ambient tempera-
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
60
## CPI installation system
Technical data – Input modules CP-E…-CL
|onnection and display components|onnection and display components||
|---|---|---|
|P-E08-M12-CL|||
|1||5<br>7<br>3<br>6<br>1 CP connection, incoming<br>2 Status LED (green)<br>3 Green LED for status display (one<br>LED per input)<br>4 Holder for inscription label<br>(IBS 8x20)<br>5 Red LED for short circuit/overload<br>indication<br>6 CP connection, outgoing|
|2<br>3||5|
|||6|
|||3|
|4||7|
||||
||||
||||
||||
||||
- 4 Holder for inscription label (IBS 8x20)
- 5 Red LED for short circuit/overload indication
- 6 CP connection, outgoing 7 Sensor connections
|in|allocation for|allocation for|sensor connections CP-E08-M12-CL|sensor connections CP-E08-M12-CL|sensor connections CP-E08-M12-CL|sensor connections CP-E08-M12-CL|
|---|---|---|---|---|---|---|
|in|allocation|||Pin|Signal|Description|
|||||1|24 V|Operating voltage 24 V|
||||||||
||||||||
||||||||
|||||2<br>3|Ix+1*<br>0 V|Sensor signal<br>Operating voltage 0 V|
||||||||
||||||||
||||||||
||||||||
|||||4|Ix*|Sensor signal|
||||||||
||||||||
|||||5|Ground|Earth terminal|
||||||||
||||||||
* Ix = Input x
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
61
## CPI installation system
Technical data – Input modules CP-E…-CL
**==> picture [488 x 223] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection and display components<br>CP-E08-M8-CL<br>1<br>2 4<br>5<br>1 CP connection, incoming<br>3 2 Status LED (green)<br>3 Holder for inscription label<br>(IBS 8x20)<br>6<br>4 Red LED for short circuit/overload<br>indication<br>5 CP connection, outgoing<br>6 Sensor connections<br>7 Green LED for status display (one<br>7 LED per input)<br>**----- End of picture text -----**<br>
|Pin allocation for sensor connections CP-E08-M8-CL|Pin allocation for sensor connections CP-E08-M8-CL|Pin allocation for sensor connections CP-E08-M8-CL|Pin allocation for sensor connections CP-E08-M8-CL|Pin allocation for sensor connections CP-E08-M8-CL|Pin allocation for sensor connections CP-E08-M8-CL|
|---|---|---|---|---|---|
|Pin allocation|Pin|Signal|Description|Pin|Signal|
||1<br>|24 V<br>|Operating voltage 24 V<br>|1<br>|24 V<br>|
||3|0 V|Operating voltage 0 V|3|0 V|
||4|Ix*|Sensor signal|4|Ix+1*|
* Ix = Input x
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
62
## CPI installation system
Technical data – Input modules CP-E…-CL
**==> picture [489 x 209] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection and display components<br>CP-E16-KL-CL<br>1<br>2 4<br>5<br>3<br>1 CP connection, incoming<br>6 2 Status LED (green)<br>3 Holder for inscription label<br>(IBS 8x20)<br>4 Red LED for short circuit/overload<br>7 indication<br>5 CP connection, outgoing<br>6 Sensor connections, plug X2<br>7 Sensor connections, plug X1<br>**----- End of picture text -----**<br>
|in allocation for sensor supply CP-E16-KL-CL|in allocation for sensor supply CP-E16-KL-CL|in allocation for sensor supply CP-E16-KL-CL|in allocation for sensor supply CP-E16-KL-CL|in allocation for sensor supply CP-E16-KL-CL|in allocation for sensor supply CP-E16-KL-CL|in allocation for sensor supply CP-E16-KL-CL|in allocation for sensor supply CP-E16-KL-CL||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|in allocation|||||Pin|Signal|Description|Pin|Signal||||
||||||Plug X1|||Plug X2|||||
||||||||||||||
||||||+|24 V DC|Operating voltage|+|24 V DC|**H**<br>-<br>-<br>Note<br>|||
||||||0<br>1|I 0<br>I 1|Connections for<br>sensors|0<br>1|I 8<br>I 9|8 sensors can be connected to each<br>**of** **the** **connections** **X1** **and** **X2**<br>.<br>|||
||||||||||||||
||||||2|I 2||2|I 10|**When** **using** **the** **three-row** **plug**<br>P**S**1**S**A**C30** **o**r|||
||||||3|I 3||3|I 11|PS1-SAC31-30POL+LED, it is<br><br><br><br>|||
||||||4|I 4||4|I 12|**ibl**<br>**h**<br>**d**<br>**d** **hi** **d**<br>poss<br>e to use t e secon an t r<br>|||
||||||5|I 5||5|I 13|**contact** **bank** **for** **the** **sensor** **power**<br>**sulviaabride**|||
||||||6|I 6||6|I 14|**pp**|**g.**||
||||||7|I 7||7|I 15||||
||||||||||||||
||||||–|0 V DC||-|0 V DC||||
||||||||||||||
|lug connection for power supply for sens|||||ors (PS1-SAC31-30POL+LED)||||||||
||||||Connection row 0|||Connection row 1|||Connection row 2||
||||||–|0 V DC|Operating voltage|-|n.c.||-|Jumper|
||||||7|I x+7|Connections for<br>sensors|7|24 V DC||7|0 V DC|
||||||6|I x+6||6|||6||
||||||5|I x+5||5|||5||
||||||4|I x+4||4|||4||
||||||3|I x+3||3|||3||
||||||2|I x+2||2|||2||
||||||1|I x+1||1|||1||
||||||0|I x||0|||0||
||||||+|24 V DC|Operating voltage|+|Jumper||+|n.c.|
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
63
## CPI installation system
Accessories – Input modules CP-E…-CL
|ng data||||
|---|---|---|---|
|ation|||Part No.<br>Type|
|modules||||
|~~I~~n<br>**Out**<br>1<br>3<br>0<br>2|positive switching||538787<br>CP-E08-M12-CL|
||positive switching||538788<br>CP-E08-M8-CL|
||positive switching||538789<br>CP-E16-KL-CL|
|||||
|plugs||||
||Plu**g,**strai**g**ht socket**,**M12|5-pin, PG7<br>|175487<br>SEA-M12-5GS-PG7<br><br>|
|||4-pin, PG7|18666<br>SEA-GS-7|
|||4-pin, 2.5 mm2 O.D.|192008<br>SEA-4GS-7-2,5|
||Strai**g**ht**p**lu**g,**M8|3-pin, solderable|18696<br>SEA-GS-M8|
|||3-pin, screw-in|192009<br>SEA-3GS-M8-S|
||Plug for 2 sensor cables, M12, PG11|4-pin<br>|18779<br>SEA-GS-11-DUO<br><br>|
|||5-pin|192010<br>SEA-5GS-11-DUO|
|||||
|ction sets for se|nsors|||
||Plug, screw-in tension-spring socket with LED|3-row, 30-pin|197162<br>PS1-SAC31-30POL+LED|
|||||
|||||
||DUO cable<br>|2x straight socket|18685<br>KM12-DUO-M8-GDGD|
|||2x straight/angled socket|18688<br>KM12-DUO-M8-GDWD|
|||2x angled socket<br>|18687<br>KM12-DUO-M8-WDWD<br><br>|
||Connecting cable, M12, 4-pin, straight plug-straight<br>**socket**|2.5 m<br>|18684<br>KM12-M12-GSGD-2,5<br>18686<br>KM12M12GSGD|
|||5.0 m|---5|
|||||
|tion labels||||
||Inscription labels 8x20 mm in frames (20 pieces)||539388<br>IBS-8x20|
|||||
|ocumentation||||
||User documentation for in**p**ut**/**out**p**ut modules|German|539299<br>P.BE.-CPEA-CL-DE|
|||English|539300<br>P.BE.-CPEA-CL-EN|
|||French|539302<br>P.BE.-CPEA-CL-FR|
|||Italian|539303<br>P.BE.-CPEA-CL-IT|
|||Spanish|539301<br>P.BE.-CPEA-CL-ES|
|||Swedish|539304<br>P.BE.-CPEA-CL-SV|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
64
## CPI installation system
Technical data – Output modules CP-A08
Application
Function Application The electrical outputs activate • Output module with 8 outputs actuators such as individual valves, 24 V DC lamps, signal equipment and many • M12 connection technology, more. with 4- or 5-pin sockets • LED display of the switching status per channel • **Sh** ort c rcu t an **i i d** over oa **l d d** etect on **i**
Note • Malfunction display by means of -Hgreen LED Optimum actuation of valves with M12 central plug.
|General technical data<br>Type<br>CP-A08-M12-5POL<br>positive switching<br>CP-A08N-M12<br>negative switching|General technical data<br>Type<br>CP-A08-M12-5POL<br>positive switching<br>CP-A08N-M12<br>negative switching|General technical data<br>Type<br>CP-A08-M12-5POL<br>positive switching<br>CP-A08N-M12<br>negative switching|
|---|---|---|
|No. of outputs|8||
|Allocation of outputs|Single allocation||
|Output connection type|8x M12, 5-pin|8x M12, 4-pin|
|Load voltage connection|M18, 4-pin||
|Bus connection|2 plugs M9, 5-pin, via prefabricated cables||
|Max. output current per channel<br>[A]|0.5||
|Operating voltage<br>[V DC]|24 ±25%||
|Load voltage connection<br>[V DC]|24 ±25%, protected against incorrect polarity||
|Fuse protection for power output<br>[A]|Electronic fuse per output 0.5||
|Intrinsic current consumption, electronics<br>[mA]|Max. 90||
|Overload/short circuit protection|Per channel||
|Switching logic|PNP to IEC 1131-2|NPN to IEC 1131-2|
|Protection class to EN 60529|IP65 (when fully plugged-in or fitted with protective cover)||
|Tem**p**erature ran**g**e<br>Operation<br>[°C]<br>Storage<br>[°C]|–5 … +50||
||–20 … +70||
|Material|Die-cast aluminium||
|Dimensions (L x W x D)<br>[mm]|172.9 x 78 x 57.1||
|Weight<br>[g]|500||
Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
65
## CPI installation system
Technical data – Output modules CP-A08
|Certifications|Certifications|
|---|---|
|This product is certified for operation in the EX range as per EU-ATEX guideline||
|ATEX category gas|II 3G|
|Ex-ignition protection type gas|Ex na II T5 X|
|ATEX category dust|II 3D|
|EX-ignition protection type dust|Ex tD A22 IP65 T80° C X|
|ATEX ambient temperature<br>[°C]|–5 ≤Ta ≤+50|
|Certification|c UL us recognized (OL)|
|CE mark (see declaration of conformity)|In accordance with EU explosion protection directive (ATEX)|
**==> picture [488 x 227] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection and display components<br>CP-A08-M12…<br>4<br>1<br>5<br>2 6<br>1 Load voltage connection<br>2 CP connection, incoming<br>3 Slot for inscription labels<br>3<br>(ISB 6x10)<br>7 4 Identifier for output type:<br>–<br>OUTPUT-P for PNP outputs<br>–<br>OUTPUT-N for NPN outputs<br>5 Status LED (green)<br>6 CP connection, outgoing<br>7 Connections for actuators<br>8 Yellow LED for status display (<br>8 one LED per output)<br>**----- End of picture text -----**<br>
|Pin allocation for load voltage connection CP-A08-M12…|Pin allocation for load voltage connection CP-A08-M12…|Pin allocation for load voltage connection CP-A08-M12…|Pin allocation for load voltage connection CP-A08-M12…|Pin allocation for load voltage connection CP-A08-M12…|Pin allocation for load voltage connection CP-A08-M12…|
|---|---|---|---|---|---|
|Connection allocation|||Pin|Signal|Designation|
||||1<br>2<br>3<br>4|n.c.<br>24 V DC ±25%|Not connected<br>Operating voltage|
|||||0 V|Operating voltage 0 V|
|||||FE (earth)|Protective earth|
|||||||
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
66
## CPI installation system
Technical data – Output modules CP-A08
|Pin allocation for outputs|Pin allocation for outputs|Pin allocation for outputs|||||||
|---|---|---|---|---|---|---|---|---|
|Terminal allocation|||Pin|Signal|Designation|Pin|Signal||
|CP-A08-M12-5POL (PNP outputs)|||||||||
||||1<br>2|n.c.<br>Ox+1|Not connected<br>Connected with|1<br>2|n.c.<br>nc|**H**<br>-<br>-<br>Note|
||||||<br>pin 4 of plug 2/<br>not connected<br>||..|Two outputs can be connected to<br>**output** **sockets** **0,** **2,** **4** **and** **6** **of** **the**|
||||3|0 V|Reference potential|3|0 V|**CP** **output** **module** **by** **means** **of** **inter**-|
||||4|Ox|Output/connected<br>with pin 2 of plug 1|4|Ox+1|nal connection between pin 2 of the<br>even numbered out**p**ut and**p**in 4 of|
||||5|Load|Earth terminal|5|Load|the opposite odd numbered output.|
||||||||||
|CP-A08-M12 (NPN outputs)|||||||||
||||1|24 V DC|Operating voltage|1|24 V DC|-**H**-<br>Note|
||||2|FE (earth)|Earth terminal|2|FE (earth)|The consuming devices/load must<br>be su**pp**lied with a 24 V o**p**eratin**g**|
||||3|n.c.|Not connected|3|n.c.|voltage via pin 1.|
||||4|Ox|Output|4|Ox+1||
||||||||||
||||||||||
* Ox = Output x
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
67
## CPI installation system
Accessories – Output modules CP-A08
|ng data|ng data|||
|---|---|---|---|
|ation|||Part No.<br>Type|
|modules||||
||positive switching||175640<br>CP-A08-M125POL|
||negative switching||18234<br>CP-A08N-M12|
|||||
|supply||||
||Power supply socket, straight, M18x1, 4-pin|for 1.5 mm2|18493<br>NTSD-GD-9|
|||for 2.5 mm2|18526<br>NTSD-GD-13,5|
||Power supply socket, angled, M18x1, 4-pin|for 1.5 mm2|18527<br>NTSD-WD-9|
|||for 2.5 mm2|533119<br>NTSD-WD-11|
|||||
|plugs||||
||Plu**g,**strai**g**ht socket**,**M12|5-pin, PG7<br>|175487<br>SEA-M12-5GS-PG7<br><br>|
|||4-pin, PG7|18666<br>SEA-GS-7|
|||4-pin, 2.5 mm2 OD|192008<br>SEA-4GS-7-2,5|
||Plug for 2 sensor cables, M12, PG11|4-pin<br>|18779<br>SEA-GS-11-DUO<br><br>|
|||5-pin|192010<br>SEA-5GS-11-DUO|
|||||
|||||
||DUO cable<br>|2x straight socket|18685<br>KM12-DUO-M8-GDGD|
|||2x straight/angled socket|18688<br>KM12-DUO-M8-GDWD|
|||2x angled socket<br>|18687<br>KM12-DUO-M8-WDWD<br><br>|
||Connecting cable, M12, 4-pin, straight plug-straight<br>**socket**|2.5 m<br>|18684<br>KM12-M12-GSGD-2,5<br>18686<br>KM12M12GSGD|
|||5.0 m|---5|
|||||
|ing||||
||Mounting for H-rail||170169<br>CP-TS-HS35|
|||||
|ocumentation||||
||User documentation for in**p**ut**/**out**p**ut modules|German|165125<br>P.BE.-CPEA-DE|
|||English|165225<br>P.BE.-CPEA-EN|
|||French|165127<br>P.BE.-CPEA-FR|
|||Italian|165157<br>P.BE.-CPEA-IT|
|||Spanish|165227<br>P.BE.-CPEA-ES|
|||Swedish|165257<br>P.BE.-CPEA-SV|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
68
## CPI installation system
Technical data – Output modules CP-A08-EL
## Application
## Function
The electrical outputs actuate actua• Output module with 8 outputs tors such as individual valves, lamps, 24 V DC signal equipment and many more. • M12, 5-pin connection technology
- M12, 5-pin connection technology
- Display of the switching status per channel via LED
- Short circuit and overload detection
- Short circuit and overload detection
- -HNote • Malfunction display by means of The output module is ideal for red LED actuation of valves with M12 central • Module supports the CPI functionplug. alit **y (** onl **y** in combination with the CPX CP interface)
- Circumferential labelling with large, hinged inscription label
- Earthing plate and H-rail mounting already integrated
|General technical data<br>Type<br>CP-A08-M12-EL-Z<br>positive switching|General technical data<br>Type<br>CP-A08-M12-EL-Z<br>positive switching|
|---|---|
|No. of outputs|8|
|Allocation of outputs|Socket 1, 3, 5 and 7 with double allocation, socket 2, 4, 6 and 8 with single<br>allocation|
|Sensor connection type|8x M12, 5-pin|
|Power supply 24 V DC|M12, 5-pin|
|Intrinsic current consumption at operating voltage<br>[mA]|Typically 35|
|Max. residual current per module<br>[A]|4|
|Max. output current per channel<br>[A]|Max. 0.5, max. 2 outputs can be connected in parallel|
|Nominal operating voltage<br>[V DC]|24|
|Operating voltage range<br>[V DC]|18 … 30|
|Fuse (short circuit)|Internal electronic fuse protection for each channel|
|Switching logic|PNP|
|Output characteristic curve|To ICE 1131-2|
|Galvanic isolation|None|
|Connection to bus node|Via pre-assembled cables|
|Dia**g**nostics|CP communication|
||Short circuit/overload per channel|
||Undervoltage|
|Dimensions (LxWxH)<br>[mm]|143 x 104 x 30|
|Weight<br>[g]|260|
Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
69
## CPI installation system
Technical data – Output modules CP-A08-EL
|Operating conditions|||
|---|---|---|
|Type||CP-A08-M12-EL-Z|
|Protection class to EN 60529||IP65 (when fully plugged in or fitted with protective cover)|
|Ambient tem**p**erature<br>O<br>S|peration<br>[°C]|–5 … +50|
||torage<br>[°C]|–20 … +70|
|Corrosion resistance class CRC1)||1|
|CE mark (see declaration of conformity)||In accordance with EU EMC directive|
|Certification||cULus listed (OL)|
|Certification C-Tick||C-Tick Declaration of ConformityCT 19823|
- 1) Corrosion resistance class 1 to Festo standard 940 070
Components requiring low corrosion resistance. Transport and storage protection. Parts that do not have primarily decorative surface requirements, e.g. in internal areas that are not visible or behind covers.
Connection and display components CP-A08-M12-EL-Z
**==> picture [333 x 168] intentionally omitted <==**
**----- Start of picture text -----**<br>
4 5 6 7 8<br>3<br>2<br>1 CP connection, outgoing<br>1 9<br>2 CP connection, incoming<br>3 Status LED (module) for short<br>circuit/overload of sensor<br>supply (red)<br>4 Status LED for CP<br>communication (green)<br>5<br>8 8 green)<br>**----- End of picture text -----**<br>
- 6 Status LEDs for outputs (status display, yellow)
- 2 CP connection, incoming
- 3 Status LED (module) for short 7 Status LED for output (channel) circuit/overload of sensor short circuit/overload supply (red) 8 Fixture for inscription label
- 4 Status LED for CP holder ASCF-H-E2 communication (green) 9 8 outputs (1 output per socket)
- 5 Status LED for load supply (PL, green)
|Pin allocation for loa|Pin allocation for loa|Pin allocation for loa|d voltage connection CP-A08-M12-EL-Z|d voltage connection CP-A08-M12-EL-Z||||
|---|---|---|---|---|---|---|---|
|Pin allocation|||||Pin|Signal|Description|
||||||1|n.c.|Not connected|
|||||||||
||||||2|24 V DC ±25%|Operating voltage|
||||||3|0 V|Operating voltage 0 V|
||||||4|FE|Protective earth|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
70
## CPI installation system
Technical data – Output modules CP-A08-EL
|Pin allocation for outputs|Pin allocation for outputs||||||
|---|---|---|---|---|---|---|
|Pin allocation|||Output 1, 3, 5 and 7||Description||
||||Pin|Signal|||
|CP-A08-M12-EL-Z (odd number||of PNP outputs)|||||
||||1|n.c.|Not connected|-H-<br>Note<br>Two outputs can be connected to<br>|
||||||||
||||2|Ox+1|Connected with<br>pin 4 of output 2|output sockets 1, 3, 5 and 7 of the<br>CP output module by means of inter-<br>nal connection between pin 2 of the<br>odd numbered output and pin 4 of<br>|
||||3|0 V|Reference potential|**the** **underlying** **even** **numbered**<br>output.|
||||||||
||||4|Ox|Output||
||||5|FE|Earth terminal||
* Ox = Output x
|Pin allocation for outputs|Pin allocation for outputs|Pin allocation for outputs||||
|---|---|---|---|---|---|
|Pin allocation|||Output 2, 4, 6 and 8||Description|
||||Pin|Signal||
|CP-A08-M12-EL-Z (even number of PNP outputs)||||||
||||1<br>|n.c.<br>|Not connected<br>|
|||||||
||||2|n.c.|Not connected|
||||3|0 V|Reference potential|
|||||||
||||4|Ox+1|Connected with pin 2 of output 1|
||||5|FE|Earth terminal|
* Ox = Output x
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
71
## CPI installation system
Accessories – Output modules CP-A08-EL
|ng data|ng data|||
|---|---|---|---|
|ation|||Part No.<br>Type|
|t modules||||
||positive switching||546924<br>CP-A08-M12-EL-Z|
|||||
|onnectors||||
||Strai**g**ht**p**lu**g,**M12|5-pin, PG7<br>|175487<br>SEA-M12-5GS-PG7<br><br>|
|||4-pin, PG7|18666<br>SEA-GS-7|
|||4-pin, 2.5 mm2 O.D.|192008<br>SEA-4GS-7-2,5|
||Plug for 2 cables, M12, PG11|4-pin<br>|18779<br>SEA-GS-11-DUO<br><br>|
|||5-pin|192010<br>SEA-5GS-11-DUO|
|||||
|cting cables||||
||DUO cable**,**1x strai**g**ht**p**lu**g**M12<br>|2x straight socket M8|18685<br>KM12-DUO-M8-GDGD|
|||1x straight socket M8 and<br>1x angled socket M8|18688<br>KM12-DUO-M8-GDWD|
|||2x angled socket M8<br>|18687<br>KM12-DUO-M8-WDWD<br><br>1)|
||Connecting cable, M12, 4-pin, straight plug-straight<br>**socket**|2.5 m<br>|539052<br>NEBU-M12G4-K-2.5-M12G4<br>02<br>NEBUM12GKM12G1)|
|||5.0 m|5395<br>-4--5-4|
|||||
|ption label holders||||
||Inscription label holders for EL modules, bag of 10||547473<br>ASCF-H-E2|
|||||
|ocumentation||||
||User documentation for in**p**ut**/**out**p**ut modules|German|539299<br>P.BE.-CPEA-CL-DE|
|||English|539300<br>P.BE.-CPEA-CL-EN|
|||French|539302<br>P.BE.-CPEA-CL-FR|
|||Italian|539303<br>P.BE.-CPEA-CL-IT|
|||Spanish|539301<br>P.BE.-CPEA-CL-ES|
|||Swedish|539304<br>P.BE.-CPEA-CL-SV|
1) Modular product, further information � Internet: nebu
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
72
## CPI installation system
Technical data – Output modules CP-A04
- Function Application The electrical outputs actuate actua• Output module with 4 outputs tors such as individual valves, lamps, 24 V DC signal equipment and many more. • M12 connection technology, with 5-pin sockets
- LED display of the switching status per c **h** anne **l**
-HNote • Short circuit and overload detection Optimum actuation for valves with • Malfunction display by means of M12 central plug. red LED
- Short circuit and overload detection
- **Module supports the CPI function-** ality (only in combination with the CPX CP interface)
|General technical data<br>Type<br>CP-A04-M12-CL<br>positive switching|General technical data<br>Type<br>CP-A04-M12-CL<br>positive switching|
|---|---|
|No. of outputs|4|
|Allocation of outputs|Socket 1 and 3 with double allocation, socket 2 and 4 with single allocation|
|Sensor connection type|4x M12, 5-pin|
|Power supply 24 V DC|From the bus node, basic unit, CP interface, etc.|
|Intrinsic current consumption of electronics<br>[mA]|Typically 35|
|Max. output current per channel<br>[A]|Max. 0.5, max. 2 outputs can be connected in parallel|
|Operating voltage<br>[V DC]|24 ±25%|
|Fuse protection for power output|Internal electronic short-circuit protection per output|
|Switching logic|PNP|
|Output characteristic curve|To ICE 1131-2|
|Galvanic isolation|None|
|Connection to bus node|Via pre-assembled cables|
|Dia**g**nostics|Undervoltage|
||Short circuit at actuator output (per channel)|
|Material|Polybutylene terephthalate|
|Dimensions (LxWxD)<br>[mm]|151 x 30 x 25|
|Weight<br>[g]|165|
Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
73
## CPI installation system
Technical data – Output modules CP-A04
|Operatingconditions|||
|---|---|---|
|Protection class to EN 60529||IP65/IP67 (when fully plugged in or fitted with protective cap)|
|Ambient tem**p**erature|Operation<br>[°C]|–5 … +50|
||Storage<br>[°C]|–20 … +70|
|Corrosion resistance class CRC1)||1|
||||
> 1) Corrosion resistance class 1 to Festo standard 940 070
Components requiring low corrosion resistance. Transport and storage protection. Parts that do not have primarily decorative surface requirements, e.g. in internal areas that are not visible or behind covers.
|Certifications|Certifications|Certifications|Certifications|Certifications|Certifications|Certifications|Certifications|
|---|---|---|---|---|---|---|---|
|Thisproduct is certified for operation in the EX range asper EU-ATEX guideline||||||||
|ATEX category gas|II 3G|||||||
|Ex-ignition protection type gas|Ex na II T5 X|||||||
|ATEX category dust|II 3D|||||||
|EX-ignition protection type dust|Ex tD A22 IP65 T80° C X|||||||
|ATEX ambient temperature<br>[°C]|–5 ≤Ta ≤+50|||||||
|Certification|c UL us recognized (OL)|||||||
|||||||||
Note -HIf device combinations are operated ture of the individual devices deterin potentially explosive areas, the lomine the possible use of the comwest common zone, the temperature plete module. class as well as the ambient tempera-
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
74
## CPI installation system
Technical data – Output modules CP-A04
**==> picture [489 x 220] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection and display components<br>CP-A04-M12-CL<br>1<br>2 4<br>5<br>1 CP connection, incoming<br>2 Status LED (green)<br>3<br>3 Holder for inscription label<br>(IBS 8x20)<br>6 4 Red LED for short circuit/overload<br>indication<br>5 CP connection, outgoing<br>6 Output<br>7 Green LED for status display (one<br>7 LED per output)<br>**----- End of picture text -----**<br>
|Pin allocation for outputs|Pin allocation for outputs|Pin allocation for outputs|||||||
|---|---|---|---|---|---|---|---|---|
|Pin allocation|||Output 1 and 3||Description|Output 2 and 4|||
||||Pin|Signal||Pin|Signal||
|CP-A08-M12-5POL (PNP||outputs)|||||||
||||1|n.c.|Not connected|1|n.c.|-**H**-<br>Note|
||||2|Ox+1|Connected with<br>pin 4 of plug 2/<br>not connected|2|n.c.|Two outputs can be connected to<br>output sockets 1 and 3 of the CP<br>output module by means of internal<br>**connectionbetweenpin2oftheodd**|
||||||||||
||||3|0 V|Reference potential|3|0 V|<br>numbered output and pin 4 of the<br>**underlying** **even** **numbered** **output.**|
||||||||||
||||4|Ox|Output/connected<br>with pin 2 of plug 1|4|Ox+1||
||||5|FE|Earth terminal|5|FE||
* Ox = Output x
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
75
## CPI installation system
Acessories – Output modules CP-A04
|ng data|ng data|||
|---|---|---|---|
|ation|||Part No.<br>Type|
|t modul||||
||Positive switching||538790<br>CP-A04_M12_CL|
|||||
|plugs||||
||Plu**g,**strai**g**ht socket**,**M12|5-pin, PG7<br>|175487<br>SEA-M12-5GS-PG7<br><br>|
|||4-pin, PG7|18666<br>SEA-GS-7|
|||4-pin, 2.5 mm2 O.D.|192008<br>SEA-4GS-7-2,5|
||Plug for 2 sensor cables, M12, PG11|4-pin<br>|18779<br>SEA-GS-11-DUO<br><br>|
|||5-pin|192010<br>SEA-5GS-11-DUO|
|||||
|||||
||DUO cable<br>|2x straight socket|18685<br>KM12-DUO-M8-GDGD|
|||2x straight/angled socket|18688<br>KM12-DUO-M8-GDWD|
|||2x angled socket<br>|18687<br>KM12-DUO-M8-WDWD<br><br>|
||Connecting cable, M12, 4-pin, straight plug-straight<br>**socket**|2.5 m<br>|18684<br>KM12-M12-GSGD-2,5<br>18686<br>KM12M12GSGD|
|||5.0 m|---5|
|||||
|tion labels||||
||Inscription labels 8x20 mm in frames (20 pieces)||539388<br>IBS-8x20|
|||||
|ocumentation||||
||User documentation for in**p**ut**/**out**p**ut modules|German|539299<br>P.BE.-CPEA-CL-DE|
|||English|539300<br>P.BE.-CPEA-CL-EN|
|||French|539302<br>P.BE.-CPEA-CL-FR|
|||Italian|539303<br>P.BE.-CPEA-CL-IT|
|||Spanish|539301<br>P.BE.-CPEA-CL-ES|
|||Swedish|539304<br>P.BE.-CPEA-CL-SV|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
76
## CPI installation system
Technical data – MPA valve terminals
CPI interface for communication -MFlow rate between an MPA valve terminal and a MPA1: Up to 360 l/min CPI master. It activates an MPA valve MPA2: Up to 700 l/min terminal with up to 32 solenoid coils on max. 32 valve positions.
-KValve width MPA1: 10 mm MPA2: 21 mm
-PVoltage 24 V DC
Note -H-
With more than 16 MPA2 solenoid coils may be switched. If more than coils an additional electrical supply 24 MPA1 or 12 MPA2 solenoid coils is absolutely necessary (after 4 elecare to be switched simultaneously, an tronic modules). additional supply must be inserted Note that without an additional elecafter the third electronic module. trical supply maximum 24 solenoid
## General technical data
Type MPA-CPI-VI ~~Ce~~ CP interface, incoming Plug M9, 5-pin ~~a~~ CP interface, outgoing Socket M9, 5-pin ~~Cn~~ Max. no. of solenoid coils 32 LED dis **p** la **y (p** roduct-s **p** ecific **)** PS Common message regarding power supply PL Power supply for valves ~~—~~ Symbol Module fault ~~— —————Ce~~ Nominal operating voltage [V DC] 24 ~~SS Ce~~ Operating voltage range [V DC] 24 _25% ~~Ce~~ Power failure bridging Logic side only [ms] 10 Current consum **p** tion at nominal Load [mA] Dependent on valve type and number of valves ~~—HH,.,.—~~ operating voltage Electronics [mA] Approx. 50 (plus current consumption of electronic modules) ~~Rna~~ Residual ripple [Vss] ~~—~~ 4 ~~Ce~~ Materials Die-cast aluminium, polyamide ~~a~~ Dimensions Internet: type 32 ~~Ce~~ Weight [g] 200 ~~a~~ Technical data on valves Internet: type 32
Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
77
## CPI installation system
Technical data – MPA valve terminals
|ngconditions|||
|---|---|---|
|on class to EN 60529||IP65 (when fully plugged in or fitted with protective cover)|
|tem**p**erature|Operation<br>[°C]|–5 … +50|
||Storage<br>[°C]|–20 … +40|
|n resistance class CRC1)||1|
|(see declaration of conformity)||In accordance with EU EMC directive|
|tion||cULus listed (OL)|
- 1) Corrosion resistance class 1 to Festo standard 940 070
Components requiring low corrosion resistance. Transport and storage protection. Parts that do not have primarily decorative surface requirements, e.g. in internal areas that are not visible or behind covers.
**==> picture [488 x 190] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connection and display components<br>3<br>1 CP connection, incoming<br>2 CP connection, outgoing<br>3 Status LEDs<br>CP system supply (green)<br>Load supply (green)<br>1 2 Module fault (red)<br>**----- End of picture text -----**<br>
|g data – Accessories|g data – Accessories|||
|---|---|---|---|
|tion|||Part No.<br>Type|
|ve terminal||||
||With CPI interface||546280<br>MPA-CPI-VI|
|||||
|rminal connection||||
||Connectin**g**cable WS-WD|0.25 m|540327<br>KVI-CP-3-WS-WD-0,25|
|||0.5 m|540328<br>KVI-CP-3-WS-WD-0,5|
|||2 m|540329<br>KVI-CP-3-WS-WD-2|
|||5 m|540330<br>KVI-CP-3-WS-WD-5|
|||8 m|540331<br>KVI-CP-3-WS-WD-8|
||Connectin**g**cable GS-GD|2 m|540332<br>KVI-CP-3-GS-GD-2|
|||5 m|540333<br>KVI-CP-3-GS-GD-5|
|||8 m|540334<br>KVI-CP-3-GS-GD-8|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
78
## CPI installation system
Technical data – CPV-SC valve terminals
CPI interface for communication -MFlow rate between a CPV-SC valve terminal and 170 l/min a CPI master. It activates a CPV-SC valve terminal with up to 16 solenoid -KValve width coils. 10 mm
- -PVoltage 24 V DC
## General technical data
Type CPVSC1-AE16-CPI ~~Ce~~ CP interface, incoming Plug M9, 5-pin ~~a~~ CP interface, outgoing Socket M9, 5-pin ~~a~~ Max. no. of solenoid coils 16 LED dis **p** la **y (p** roduct-s **p** ecific **)** Status LED for CP communication Status LEDs for valves ~~a~~ Nominal operating voltage [V DC] 24 ~~a~~ Operating voltage range [V DC] 20.4 … 26.4 ~~a~~ Power failure bridging Logic side only [ms] 10 Current consum **p** tion at nominal Load [mA] ~~PC~~ Dependent on valve type and number of valves operating voltage Electronics [mA] ~~PC~~ Max. 100 ~~a~~ Materials Polymer ~~a~~ Dimensions Internet: type 80 ~~a~~ Weight [g] 150 ~~a~~ Technical data on valves Internet: type 80
Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
79
## CPI installation system
Technical data – CPV-SC valve terminals
|atingconditions|||
|---|---|---|
|ction class to EN 60529||IP40 (when fully plugged in or fitted with protective cover)|
|ent tem**p**erature|Operation<br>[°C]<br>Storage<br>[°C]|–5 … +50|
|||–20 … +40|
|sion resistance class CRC1)||1|
|ark (see declaration of conformity)||In accordance with EU EMC directive|
|ication||c UL us Recognized (OL)|
- 1) Corrosion resistance class 1 to Festo standard 940 070
Components requiring low corrosion resistance. Transport and storage protection. Parts that do not have primarily decorative surface requirements, e.g. in internal areas that are not visible or behind covers.
|ection and display components|ection and display components|ection and display components|ection and display components|ection and display components|ection and display components|||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||||||1 CP connection, incoming<br>2 CP connection, outgoing<br>3 Status LED for CP<br>communication<br>4 Status LEDs for valves||
|||||4||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|2||3||1||||||||
|||||||||||||
|ring data – Accessories||||||||||||
|nation|||||||||||Part No.<br>Type|
|SC valve terminals||||||||||||
||with CPI interface||||||||||541975<br>CPVSC1-AE16-CPI|
|||||||||||||
|terminal connection||||||||||||
||Connectin**g**cable WS-WD|||||||||0.25 m|540327<br>KVI-CP-3-WS-WD-0,25|
|||||||||||0.5 m|540328<br>KVI-CP-3-WS-WD-0,5|
|||||||||||2 m|540329<br>KVI-CP-3-WS-WD-2|
|||||||||||5 m|540330<br>KVI-CP-3-WS-WD-5|
|||||||||||8 m|540331<br>KVI-CP-3-WS-WD-8|
||Connectin**g**cable GS-GD|||||||||2 m|540332<br>KVI-CP-3-GS-GD-2|
|||||||||||5 m|540333<br>KVI-CP-3-GS-GD-5|
|||||||||||8 m|540334<br>KVI-CP-3-GS-GD-8|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
80
## CPI installation system
Technical data
**==> picture [489 x 385] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions – Fieldbus node/control block Download CAD data � www.festo.com<br>CPX-FB… /CPX-FEC and CPX-CP-4-FB<br>1 Mounting holes 3 H-rail 5 CPX fieldbus node or CPX control 6 CPX-CP interface<br>2 Earthing screw 4 H-rail mounting block<br>**----- End of picture text -----**<br>
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
81
## CPI installation system
Technical data
**==> picture [488 x 355] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions Download CAD data � www.festo.com<br>Fieldbus node<br>1 Slots for inscription label 2 Earthing screw<br>3 H-rail with support base<br>**----- End of picture text -----**<br>
Note -H-
- The dimensions are valid for the Different height ~110 (incl. fieldbus fieldbus node types: plug) for • CP-FB05-E • CP-FB06-E with M23 • CP-FB06-E • CP-FB11-E with M12 • CP-FB11-E • CP-FB13-E with 2x M12 • CP-FB13-E
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
82
## CPI installation system
Technical data
**==> picture [489 x 597] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions – Sturdy input modules Download CAD data � www.festo.com<br>CP-E16-M8<br>1 Slots for inscription label 2 Earthing screw M3 3 Protective cap (included in 4 H-rail with support base<br>scope of delivery)<br>CP-E16-M8-Z<br>1 Slots for inscription label 2 Earthing screw M3 3 Protective cap (included in 4 H-rail with support base<br>scope of delivery)<br>**----- End of picture text -----**<br>
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
83
## CPI installation system
Technical data
**==> picture [488 x 314] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions – Sturdy input modules Download CAD data � www.festo.com<br>CP-E16-M12x2-5POL/CP-E16N-M12x2<br>1 Slots for inscription label 2 Earthing screw M3 3 Protective cap (included in 4 H-rail with support base<br>scope of delivery)<br>**----- End of picture text -----**<br>
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
84
## CPI installation system
Technical data
|D|imension|s – Economical input modules|s – Economical input modules|s – Economical input modules|s – Economical input modules|s – Economical input modules||||||Download CAD data�www.festo.com|
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|C|P-E16-M8|-EL|||||||||||
|||||||||||||1 Through-hole for surface<br>mounting<br>2 H-rail<br>3 Mounting kit for H-rail<br>(included in the scope of<br>delivery)|
||||||||||||||
||||||||||||||
||||||||||||||
||||||||||||||
||||||||||||||
||||||||||||||
|C|P-E16-M12-EL||||||||||||
|||||||||||||1 Through-hole for surface<br>mounting<br>2 H-rail<br>3 Mounting kit for H-rail<br>(included in the scope of<br>delivery)|
||||||||||||||
||||||||||||||
||||||||||||||
||||||||||||||
||||||||||||||
|C|P-E32-M8|-EL|||||||||||
|||||||||||||1 Through-hole for surface<br>mounting<br>2 H-rail<br>3 Mounting kit for H-rail<br>(included in the scope of<br>delivery)|
||||||||||||||
||||||||||||||
||||||||||||||
||||||||||||||
||||||||||||||
||||||||||||||
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
85
## CPI installation system
Technical data
**==> picture [488 x 318] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions – Sturdy output modules Download CAD data � www.festo.com<br>CP-A08-M12-5/CP-A08N-M12<br>1 Slots for inscription label 2 Earthing screw M3 3 Protective cap (included in 4 H-rail with support base<br>scope of delivery)<br>**----- End of picture text -----**<br>
**==> picture [488 x 204] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions – Economical output module Download CAD data � � www.festo.com<br>CP-A08-M12-EL-Z<br>1 Through-hole for surface<br>mounting<br>2 H-rail<br>3 Mounting kit for H-rail<br>(included in the scope of<br>delivery)<br>**----- End of picture text -----**<br>
**==> picture [488 x 204] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions – Economical output module Download CAD data � � www.festo.com<br>CP-A08-M12-EL-Z<br>1 Through-hole for surface<br>mounting<br>2 H-rail<br>3 Mounting kit for H-rail<br>(included in the scope of<br>delivery)<br>**----- End of picture text -----**<br>
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
86
## CPI installation system
Technical data
**==> picture [489 x 153] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions – Compact CP modules Download CAD data � www.festo.com<br>CP-E08-M12-CL/CP-A04-M12-CL<br>**----- End of picture text -----**<br>
## CP-E08-M8-CL
## CP-E16-KL-CL
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
87
## CPI installation system
Order processing information
|Configuration guidelines||||
|---|---|---|---|
|The CPI system supports a certain|master and the CP modules|CP masters and CP modules can be|• With CPI functionality|
|number of modules per CP string|connected.|split into two different groups:|• Without CPI functionality|
|depending on the type of the CP||||
|CP modules with CPI functionality||CP modules without CPI functionality||
|CP modules with CPI functionality offer|• Max. 4 modules per CP string|Sturdy CP modules offer the following|can only be positioned at the end of|
|the following features:|• Max. 32 inputs and outputs can be|features:|a CP string|
|• Incoming and outgoing CP interface|connected to each string depending|• CP valve terminals and CP output|• All CP modules with CPI functional-|
|• Any arrangement of the modules|on the version|modules have an incoming and|ity can also be connected to CP|
|within a CP string||outgoing CP interface|masters without extended|
|||• CP input modules only have an in-|functionality|
|||coming CP interface and therefore||
|Information on using CP modules with and without CPI functionality||||
|A mixture of CP modules with and|• Only one input module without CPI|• Only one CP valve terminal or out-|• Free positions in the CP string can|
|without CPI functionality is possible.|functionality is possible per CP|put module without CPI functional-|be filled by CP modules with CPI|
|The following must be noted in this|string (at the end of a CP string)|ity is possible per CP string (any|functionality (max. 4 modules)|
|regard:||point in the CP string)||
|-H-<br>Note||||
|The cable length for any given string|The maximum number of inputs|||
|may not exceed 10 m.|and outputs that can be connected|||
||is 32 each (sum of all CP modules|||
|Connecting cables are available in|on a CP string), regardless of the|||
|lengths of 0.25 m, 0.5 m, 2 m, 5 m|type of CP module (with or without|||
|and 8 m|CPI functionality).|||
|�91||||
|Order processing||||
|There is one way of placing an order|To correctly allocate a CP string,||The valve terminals are configured|
|for the electrical CPI installation|proceed as follows:||separately:|
|system:|• First select a connecting cable of||• CPV valve terminal|
|• Digitally using the valve terminal|appropriate length.||CPV10/14/18-VI-FB-….|
|configurator|• Then select an input/output||�Internet: type 10|
||module.||• MPA valve terminals|
|Please note that the CP strings must|• Continue in this way until the string||MPA-CPI-VI|
|be allocated in ascending numerical|is fully allocated (max. 4 strings for||�Internet: type 32|
|order, i.e. starting with string 1,|CP modules with extended||• CPV-SC valve terminals|
|followed by string 2, etc. without|functionality).||CPVSC1-AE16-CPI|
|omitting any numbers.|||�Internet: type 80|
||||• CPA valve terminals|
||||CPA10/14-IFB-CP….|
||||�Internet: type 12|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
88
## CPI installation system
Accessories
|ing data|ing data|||
|---|---|---|---|
|nation|||Part No.<br>Type|
|onnectors – Power supply||||
||Power supply socket, straight, M18x1, 4-pin|for 1.5 mm2|18493<br>NTSD-GD-9|
|||for 2.5 mm2|18526<br>NTSD-GD-13,5|
||Power supply socket, angled, M18x1, 4-pin|for 1.5 mm2|18527<br>NTSD-WD-9|
|||for 2.5 mm2|533119<br>NTSD-WD-11|
||Power supply socket for CPX system supply|7/8” connection, 5-pin|543107<br>NECU-G78G5-C2|
|||7/8” connection, 4-pin|543108<br>NECU-G78G4-C2|
|||||
|ction sets for power supply and sensors||||
||Plug, screw-in tension-spring socket|3-row, 30-pin|197161<br>PS1 SAC30|
||Plug, screw-in tension-spring socket with LED|3-row, 30-pin|197162<br>PS1-SAC31-30POL+LED|
|||||
|r plugs||||
||Plu**g**M12**,**strai**g**ht socket|5-pin, PG7<br>|175487<br>SEA-M12-5GS-PG7<br><br>|
|||4-pin, PG7|18666<br>SEA-GS-7|
|||4-pin, 2.5 mm2 O.D.|192008<br>SEA-4GS-7-2,5|
||Plu**g**M8**,**strai**g**ht|3-pin, solderable|18696<br>SEA-GS-M8|
|||3-pin, screw-in|192009<br>SEA-3GS-M8-S|
||Plug M12 for 2 sensor cables, PG11|4-pin<br>|18779<br>SEA-GS-11-DUO<br><br>|
|||5-pin|192010<br>SEA-5GS-11-DUO|
||Push-in T-connector|2x socket M8, 3-pin<br>1x plug M8, 4-pin|544391<br>NEDU-M8D3-M8T4|
||Push-in T-connector|2x socket M12, 5-pin<br>1x plug M12, 4-pin|541596<br>NEDU-M12D5-M12T4|
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
89
## CPI installation system
Accessories
|ing data|ing data|||
|---|---|---|---|
|nation|||Part No.<br>Type|
|onnectors – Fieldbus connection||||
||Sub-D**p**lu**g**for INTERBUS|Incoming|532218<br>FBS-SUB-9-BU-IB-B|
|||Outgoing|532217<br>FBS-SUB-9-GS-IB-B|
||Sub-D plug for DeviceNet/CANopen||532219<br>FBS-SUB-9-BU-2x5POL-B|
||Sub-D plug for Profibus DP||532216<br>FBS-SUB-9-GS-DP-B|
||Sub-D plug for CC-Link||532220<br>FBS-SUB-9-GS-2x4POL-B|
||Sub-D plug||534497<br>FBS-SUB-9-GS-1x9POL-B|
||Bus connection M12, 5-pin, adapter (B-coded) for Profibus DP||533118<br>FBA-2-M12-5POL-RK|
||Bus connection Micro Style 2xM12, 5-pin, for DeviceNet/CANopen||525632<br>FBA-2-M12-5POL|
||Socket M12, 5-pin, for Micro Style connection<br>||18324<br>FBSD-GD-9-5POL<br>|
||Plug M12, 5-pin, for Micro Style connection||175380<br>FBS-M12-5GS-PG9|
||Bus connection M12x1, 4-pin (D-coded) for Ethernet||543109<br>NECU-M-S-D12G4-C2-ET|
||Connection block M12 adapter (B-coded) for Profibus DP<br>blk d dd f||541519<br>CPX-AB-2-M12-RK-DP<br><br>|
||Connection oc M12 aapter (B-coe) or INTERBUS||534505<br>CPX-AB-2-M12-RK-IB|
||Socket M12x1, 5-pin, straight,<br>for self-assembly of a connecting cable<br>for FBA-2-M12-5POL-RK and CPX-AB-2-M12-RK-DP||1067905<br>NECU-M-B12G5-C2-PB|
||Plug M12x1, 5-pin, straight,<br>for self-assembly of a connecting cable<br>for FBA-2-M12-5POL-RK and CPX-AB-2-M12-RK-DP||1066354<br>NECU-M-S-B12G5-C2-PB|
||Bus connection Open Style for 5-pin terminal strip for DeviceNet/CANopen||525634<br>FBA-1-SL-5POL|
||Bus connection 5-pin terminal strip for DeviceNet/CANopen||525635<br>FBSD-KL-2x5POL|
||Bus connection screw terminal for CC-Link||197962<br>FBA-1-KL-5POL|
||RJ45/plug||534494<br>FBS-RJ45-8-GS|
|||||
|sories – Fieldbus connection||||
||Cover for CPX-AB-8-KL-4POL (IP65/67)<br>– 8 cable through-feeds M9<br>– 1 cable through-feed for multi-pin plug||538219<br>AK-8KL|
||Screening plate for M12 connections||526184<br>CPX-AB-S-4-M12|
||Earthing element for right-hand/left-hand end plates (5 pieces)||538892<br>CPX-EPFE-EV|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
90
## CPI installation system
Accessories
|ing data||||
|---|---|---|---|
|nation|||Part No.<br>Type|
|cting cables||||
||DUO cable M12-2xM8, 4-pin/2x3-pin<br>|2x straight socket|18685<br>KM12-DUO-M8-GDGD|
|||2x straight/angled socket|18688<br>KM12-DUO-M8-GDWD|
|||2x angled socket<br>|18687<br>KM12-DUO-M8-WDWD<br><br>|
||Connectin**g**cable M8-M8**,**strai**g**ht**p**lu**g**-strai**g**ht socket|0.5 m|175488<br>KM8-M8-GSGD-0,5|
|||1.0 m|175489<br>KM8-M8-GSGD-1|
|||2.5 m|165610<br>KM8-M8-GSGD-2,5|
|||5.0 m|165611<br>KM8-M8-GSGD-5|
||Extension cable M12-M12**,** **5**-**p**in**,**strai**g**ht**p**lu**g**-strai**g**ht<br>socket|1.5 m|529044<br>KV-M12-M12-1,5|
|||3.5 m|530901<br>KV-M12-M12-3,5|
||Connectin**g**cable M12-M12**,**4-**p**in**,**strai**g**ht**p**lu**g**-<br>straight socket|2.5 m|18684<br>KM12-M12-GSGD-2,5|
|||5.0 m|18686<br>KM12-M12-GSGD-5|
||Connecting cable M12-M12, 4-pin, straight plug-<br>angled socket|1.0 m|185499<br>KM12-M12-GSWD-1-4|
||Modular system for connecting cables||–<br>NEBU-…<br>�Internet: nebu|
||Programming cable||151915<br>KDI-PPA-3-BU9|
||Connecting cable FED, pre-assembled at one end||539642<br>FEC-KBG7|
||Connecting cable FED, pre-assembled at both ends||539643<br>FEC-KBG8|
|||||
|cting cable – CP modules||||
||Connectin**g**cable WS-WD**,**an**g**led**p**lu**g**-an**g**led socket|0.25 m|540327<br>KVI-CP-3-WS-WD-0,25|
|||0.5 m|540328<br>KVI-CP-3-WS-WD-0,5|
|||2 m|540329<br>KVI-CP-3-WS-WD-2|
|||5 m|540330<br>KVI-CP-3-WS-WD-5|
|||8 m|540331<br>KVI-CP-3-WS-WD-8|
||Connectin**g**cable GS-GD**,**strai**g**ht**p**lu**g**-strai**g**ht socket|2 m|540332<br>KVI-CP-3-GS-GD-2|
|||5 m|540333<br>KVI-CP-3-GS-GD-5|
|||8 m|540334<br>KVI-CP-3-GS-GD-8|
||Connector plug for CP cable (control cabinet implementation)||543252<br>KVI-CP-3-SSD|
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
91
## CPI installation system
Accessories
|ing data|ing data|||
|---|---|---|---|
|nation|||Part No.<br>Type|
|ctive caps||||
||Inspection cover, transparent||533334<br>AK-SUB-9/15-B|
||Cover for RJ45 connection||534496<br>AK-Rj45|
||Protective ca**p**for sealin**g**unused sockets**(**10**p**ieces**)**|for M8 connections|177672<br>ISK-M8|
|||M9|356684<br>FLANSCHDOSE SER.712|
|||for M12 connections|165592<br>ISK-M12|
|||||
|ting attachments||||
||Retainer CPX-MMI||534705<br>CPX-MMI-1-H|
||Mounting for H-rail, CPX-MMI||536689<br>CPX-MMI-1-NRH|
||Mounting for H-rail, CP modules||170169<br>CP-TS-HS35|
||Mounting for H-rail||18649<br>IBGH-03-4,0|
|||||
|ption labels||||
||Inscription labels 6x10 mm in frames (64 pieces)||18576<br>IBS-6x10|
|||||
|||||
|||||
|||||
||Inscription labels 8x20 mm in frames (20 pieces) for compact modules (CP-…-CL)||539388<br>IBS-8x20|
|||||
|||||
|||||
|||||
||Inscription label holders for EL modules, bag of 10||547473<br>ASCF-H-E2|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
92
## CPI installation system
Accessories
|Ordering data – Documentation|Ordering data – Documentation|Ordering data – Documentation|Ordering data – Documentation|||
|---|---|---|---|---|---|
|Designation|||||Part No.<br>Type|
||||User documentation for bus node CPX-FB6|German|526433<br>P.BE-CPX-FB6-DE|
|||||English|526434<br>P.BE-CPX-FB6-EN|
|||||Spanish|526435<br>P.BE-CPX-FB6-ES|
|||||French|526436<br>P.BE-CPX-FB6-FR|
|||||Italian|526437<br>P.BE-CPX-FB6-IT|
|||||Swedish|526438<br>P.BE-CPX-FB6-SV|
||||User documentation for bus node CPX-FB11|German|526421<br>P.BE-CPX-FB11-DE|
|||||English|526422<br>P.BE-CPX-FB11-EN|
|||||Spanish|526423<br>P.BE-CPX-FB11-ES|
|||||French|526424<br>P.BE-CPX-FB11-FR|
|||||Italian|526425<br>P.BE-CPX-FB11-IT|
|||||Swedish|526426<br>P.BE-CPX-FB11-SV|
||||User documentation for bus node CPX-FB1**3**|German|526427<br>P.BE-CPX-FB13-DE|
|||||English|526428<br>P.BE-CPX-FB13-EN|
|||||Spanish|526429<br>P.BE-CPX-FB13-ES|
|||||French|526430<br>P.BE-CPX-FB13-FR|
|||||Italian|526431<br>P.BE-CPX-FB13-IT|
|||||Swedish|526432<br>P.BE-CPX-FB13-SV|
||||User documentation for bus node CPX-FB14|German|526409<br>P.BE-CPX-FB14-DE|
|||||English|526410<br>P.BE-CPX-FB14-EN|
|||||Spanish|526411<br>P.BE-CPX-FB14-ES|
|||||French|526412<br>P.BE-CPX-FB14-FR|
|||||Italian|526413<br>P.BE-CPX-FB14-IT|
|||||Swedish|526414<br>P.BE-CPX-FB14-SV|
||||User documentation for bus node CPX-FB2**3**|German|526403<br>P.BE-CPX-FB23-DE|
|||||English|526404<br>P.BE-CPX-FB23-EN|
||||User documentation for bus node CPX-FB**3**2|German|693134<br>P.BE-CPX-FB32-DE|
|||||English|693135<br>P.BE-CPX-FB32-EN|
|||||Spanish|693136<br>P.BE-CPX-FB32-ES|
|||||French|693137<br>P.BE-CPX-FB32-FR|
|||||Italian|693138<br>P.BE-CPX-FB32-IT|
|||||Swedish|693139<br>P.BE-CPX-FB32-SV|
||||User documentation for bus node CPX-FB**33**|German|548759<br>P.BE-CPX-PNIO-DE|
|||||English|548760<br>P.BE-CPX-PNIO-EN|
|||||Spanish|548761<br>P.BE-CPX-PNIO-ES|
|||||French|548762<br>P.BE-CPX-PNIO-FR|
|||||Italian|548763<br>P.BE-CPX-PNIO-IT|
|||||Swedish|548764<br>P.BE-CPX-PNIO-SV|
||||User documentation for control block CPX-FEC|German|538474<br>P.BE-CPX-FEC-DE|
|||||English|538475<br>P.BE-CPX-FEC-EN|
|||||Spanish|538476<br>P.BE-CPX-FEC-ES|
|||||French|538477<br>P.BE-CPX-FEC-FR|
|||||Italian|538478<br>P.BE-CPX-FEC-IT|
|||||Swedish|538479<br>P.BE-CPX-FEC-SV|
� Internet: www.festo.com/catalogue/...
2010/03 – Subject to change
93
## CPI installation system
Accessories
|Ordering data – Documentation|Ordering data – Documentation|Ordering data – Documentation|Ordering data – Documentation|||
|---|---|---|---|---|---|
|Designation|||||Part No.<br>Type|
||||User documentation for CPX CP interface|German|539293<br>P.BE-CPX-CP-DE|
|||||English|539294<br>P.BE-CPX-CP-EN|
|||||Spanish|539295<br>P.BE-CPX-CP-ES|
|||||French|539296<br>P.BE-CPX-CP-FR|
|||||Italian|539297<br>P.BE-CPX-CP-IT|
|||||Swedish|539298<br>P.BE-CPX-CP-SV|
||||User manual for o**p**erator unit CPX-MMI-1|German|534824<br>P.BE-CPX-MMI-1-DE|
|||||English|534825<br>P.BE-CPX-MMI-1-EN|
|||||French|534827<br>P.BE-CPX-MMI-1-FR|
|||||Italian|534828<br>P.BE-CPX-MMI-1-IT|
|||||Swedish|534829<br>P.BE-CPX-MMI-1-SV|
|||||Spanish|534826<br>P.BE-CPX-MMI-1-ES|
||||User documentation for sturd**y**in**p**ut**/**out**p**ut modules|German|165125<br>P.BE.-CPEA-DE|
|||||English|165225<br>P.BE.-CPEA-EN|
|||||French|165127<br>P.BE.-CPEA-FR|
|||||Italian|165157<br>P.BE.-CPEA-IT|
|||||Spanish|165227<br>P.BE.-CPEA-ES|
|||||Swedish|165257<br>P.BE.-CPEA-SV|
||||User documentation for com**p**act in**p**ut**/**out**p**ut modules|German|539299<br>P.BE.-CPEA-CL-DE|
|||||English|539300<br>P.BE.-CPEA-CL-EN|
|||||French|539302<br>P.BE.-CPEA-CL-FR|
|||||Italian|539303<br>P.BE.-CPEA-CL-IT|
|||||Spanish|539301<br>P.BE.-CPEA-CL-ES|
|||||Swedish|539304<br>P.BE.-CPEA-CL-SV|
||||S**y**stem descri**p**tion|German|165126<br>P.BE-CPSYS-DE|
|||||English|165226<br>P.BE-CPSYS-EN|
|||||French|165128<br>P.BE-CPSYS-FR|
|||||Italian|165158<br>P.BE-CPSYS-IT|
|||||Spanish|165228<br>P.BE-CPSYS-ES|
|||||Swedish|165258<br>P.BE-CPSYS-SV|
|||||||
|Software||||||
||||Programming software|German|537927<br>FST4.1DE|
|||||English|537928<br>FST4.1GB|
� Internet: www.festo.com/catalogue/...
Subject to change – 2010/03
94
Updated at June 9, 2026
Festo is a globally recognized leader in industrial automation, renowned for its innovative pneumatic and electrical control and drive technologies. As an engineering-driven company, Festo provides robust, high-quality components designed to optimize both factory and process automation systems across a wide range of demanding industries. A cornerstone of their automation expertise is a comprehensive portfolio of precision sensory technology. The core of this offering is focused on advanced pressure sensors and transducers. These vital components are engineered to deliver highly accurate fluid and gas measurements, ensuring reliable monitoring, system safety, and optimal efficiency in complex industrial environments. Complementing their fluid control solutions, Festo also manufactures a dependable selection of proximity sensors and proximity switches. Built for durability and precise object detection, these sensors provide the essential positional feedback required to maintain seamless and automated operational workflows.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →