Image not available
Illustrative purposes only
47216
AC/DC PCB Mount Power Supply (PSU), ITE, 1 Output, 10 W, 3.3 VDC, 3 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MYRRA
- Product type: AC / DC PCB Mount Power Supplies
- No. of Outputs:1 Output; Output Power Max:10W; Output Voltage - Output 1:3.3V; Output Current - Output 1:3A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - Outpu
- SVHC: No SVHC (17-Dec-2015)
- Depth: 48mm
- Width: 40mm
- Height: 26mm
- Product Range: 47000 Series
- No. of Outputs: 1 Output
- Output Power Max: 10W
- Input Voltage VAC: 85V AC to 265V AC
- Input Voltage AC Max: 265V
- Input Voltage AC Min: 85V
- Power Supply Output Type: Fixed
- Output Current - Output 1: 3A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 3.3VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 9.0 € |
| Current stock | 10+ |
| Lead time | 30 days |
ONE OUTPUT 10W – Regulated ~~OE~~ ## **MAIN FEATURES:** - **10W Small Compact Size - PCB Mount** - **Single Output - Regulated** - **Output Range : 3.3VDC - 24VDC** - **Input Range : 85VAC - 265VAC/47 - 63Hz Or 120VDC - 370VDC** - **Very Low Standby Power Consumption < 0.1W** - **Better Energetic Efficiency : Meet Requirements Of Energy Star And EC Code Of Conduct** - **Encapsulated Design And Same Footprint As EI48 Transformer: Upgrade Your Application Without Redesign Of PCB** - ○ **Safety : IEC/EN61558-2-16,IEC/EN60950,IEC/EN60335, UL/CUL60950,CE,VDE,ENEC Mark** - **Materials : Uses UL 94-V0 Plastic And Resin** - **EMC : Conducted And Radiated Emissions Conform To EN55014 CLASS B , EN55022 CLASS B And FCC Part 15** - **Immunity Conform To EN61000-3-3** , **EN61000-4-2,** **EN61000-4-3,EN61000-4-4** , **EN61000-4-5, EN61000-4-6,** **EN61000-4-8, EN61000-4-11** |Part<br>No|Power Rating<br>Watts|Output<br>Voltage<br>(VDC)|Output<br>Current<br>(mA)|Ambient<br>Temp.<br>(℃)|Efficiency<br>Typical|Input Range| |---|---|---|---|---|---|---| |47210|10<br>~~lL~~|5<br>~~lL~~|2000<br>~~lL~~|60<br>~~lL~~|>74%@230VAC<br>~~lL~~|85VAC-265VAC<br>(120VDC-370VDC)| |47211|10<br>~~lL~~|9<br>~~lL~~|1100<br>~~lL~~|60<br>~~lL~~|>80%@230VAC<br>~~lL~~|| |47212|10<br>~~lLUhe~~|12<br>~~lLUhe~~|830<br>~~lLUhe~~|60<br>~~lLUhe~~|>82%@230VAC|| |47213|10<br>~~lLUhe~~|15<br>~~lLUhe~~|670<br>~~lLUhe~~|60<br>~~lLUhe~~||| |47214|10<br>~~lL~~|18<br>~~lL~~|560<br>~~lL~~|60<br>~~lL~~||| |47215|10<br>~~lL~~|24<br>~~lL~~|420<br>~~lL~~|60<br>~~lL~~||| |47216|10|3.3|3000<br>~~tim~~|50<br>~~tim~~|>72%@230VAC<br>~~tim~~|| |Note: Other Output Voltages Are Available Upon Request||||||| Note: Other Output Voltages Are Available Upon Request Revision: 3 Page: 1 of 6 www.myrra.com The information contained in this document is subject to change without notice. ## ONE OUTPUT 10W – Regulated |**Model: 10 Watt**|**Model: 10 Watt**|**Specification**| |---|---|---| |AC Input<br>Characteristics|Rated AC input Voltage|100~240Vac Or 140VDC-340VDC| ||AC Input Voltage Range|85~265Vac Or 120VDC-370VDC| ||AC Input Frequency Range|47Hz~63Hz| ||Rated AC Input Frequency|50/60Hz| ||Input Current|0.4A Max@85Vac~265Vac, at full load| ||Input Inrush Current|40A Max @85Vac~265Vac input, cold start, full load| ||Standby Power|0.1W Max(Meet Requirements Of Energy Star And EC<br>Code Of Conduct)| |DC Output<br>Characteristics|Output Voltage Accuracy|± 2% (9V,12V,15V,18V,24V Types)<br>± 3% (5V Type)<br>± 4%(3.3V Type)| ||Output<br>Voltage<br>Line<br>Regulation|± 0.5%(9V,12V,15V,18V,24V Types)<br>± 1%(3.3V and 5V Types )| ||Output<br>Voltage<br>Load<br>Regulation|± 1%(9V,12V,15V,18V,24V Types)<br>± 3% (5V Type)<br>± 4%(3.3V Type)| ||Ripple & Noise|Max 150mVp-p @Rated AC input (The measuring<br>will be terminated with a 47uF AL E-Cap and a 0.1uF<br>Cer-Cap. An oscilloscope set at 20MHz bandwidth)| ||Dynamic Response|The output voltage shall not exceed ±10% rated output<br>voltage @ 10%←→90% Load change, 1A/uS , 1KHz<br>50% duty cycle| ||Overshoot|The output voltage shall not exceed +10% rated output<br>voltage @ Power on and 85Vac~265Vac input, and DC<br>with full load| ||Undershoot|The output voltage shall not exceed -10% rated output| Revision: 3 Page: 2 of 6 www.myrra.com The information contained in this document is subject to change without notice. ## ONE OUTPUT 10W – Regulated |||output with full load| |---|---|---| ||Hold Up Time|5mS Min@ 100Vac ~240Vac, DC output with full load| ||Turn On Delay|3S max @ 85Vac~265Vac input and DC output with full<br>load| ||Rise Time|50ms Max @ 85Vac~265Vac input and DC output with<br>full load| ||Efficiency|See table (Meet Requirements Of Energy Star And EC<br>Code Of Conduct)| |Protection<br>Characteristics|Over Current Protection|The power supply shall automatic protection. The<br>power supply shall auto-recovery normal operation<br>after the deformation is removed. No excessive heat,<br>odor, or plastic deformation shall occur, no safety<br>hazard| ||Output<br>Short<br>Circuit<br>Protection|The power supply shall withstand a continuous output<br>short without damage in 24 hours; The short may be<br>applied before power on, or after power on; The<br>power supply shall resume normal operation after the<br>short is removed, no excessive heat, odor, or plastic<br>deformation shall occur, no safety hazard| ||Over<br>temperature<br>protection|Thepower supplyshall shut down when the<br>junction temperature of PWM controller exceeds<br>the thermal shutdown temperature ,typically<br>140°C±10°C.| |Environmental|Operation Temperature|-25°C ~ +Ta (see table)| ||Operation Humidity|10~ 90% RH(No Condensing) @ full load| ||Storage Temperature|-40°C~ +85°C| ||Storage Humidity|5%~95%| ||Cooling Method|Ordinary or thermostat| Revision: 3 Page: 3 of 6 www.myrra.com The information contained in this document is subject to change without notice. ## ONE OUTPUT 10W – Regulated x) es |Safety & EMC<br>Requirement|Dielectric Strength|Primary to Secondary: 4000Vac 5mA, 3 sec .| |---|---|---| ||Radiation|Meeting EN55022,EN55014,FCC, part 15, Class B.<br>under 3dB margin| ||Conduction|Meeting EN55022,EN55014, FCC, part 15,Class B.<br>under 3dB margin| ||Power Clamp Radiation|Meeting EN 55014-1: 2006+A1: 2009+A2:2011| ||Lightning Surge|Meeting EN61000-4-5:2006, Level II. ±2KV| ||Electric Fast Transient|Meeting EN61000-4-4:2012,±4KV| ||Voltage Dips And<br>Interruptions|Meeting EN61000-4-11:2004| ||Voltage Fluctuation And<br>Flicker|Meeting EN61000-3-3:2013| ||Electrostatic Discharge|Meeting EN61000-4-2:2009<br>Contact Discharge ±4KV,Air Discharge ±8KV| ||RF Field Strength<br>Susceptibility|Meeting EN61000-4-3:2006+A1:2008+A2:2010| ||Conducted Susceptibility|Meeting EN61000-4-6:2014| ||Power Frequency Magnetic<br>Field Susceptibility|Meeting EN61000-4-8:2010| ||Safety Standards|Meet all requirements of<br>UL/CUL60950<br>IEC/EN60950<br>IEC/EN60335<br>IEC/EN61558-2-16<br>CE,VDE,And ENEC Mark| |Reliability<br>Requirement|MTBF|Calculated by MIL-HDBK-217-F2<br>5V ,9V,12V,15V,18V,24V Types:<br>200K Hours Min. @230VAC input, 60deg.C<br>3.3V type:200K Hours Min. @230VAC input, 50deg.C| ||Burn-In Test|The unit shall be burned in for 2~ 5hours under 230Vac<br>input and DC with full load at an ambient temperature| Revision: 3 Page: 4 of 6 www.myrra.com The information contained in this document is subject to change without notice. ## ONE OUTPUT 10W – Regulated |||of 30~45 degrees C| |---|---|---| |Mechanical|Physical Size|The units do not including PINs of input and output,<br>and dimension is<br>(L)48.0*(W)40.0*(H)26.0± 0.5mm<br>(see appearance drawing)| ||Net Weight|About 80.2 grams per product unit.| |Guarantee|This product meet to RoHS standard|| ## **SCHEMATIC** Revision: 3 Page: 5 of 6 www.myrra.com The information contained in this document is subject to change without notice. ## ONE OUTPUT 10W – Regulated ## **DERATING GRAPH** ## **DIMENSIONS And PINOUT** ## **4 PINS** ## **PRI:** ## **Pins 1 – 5: AC Or DC Input** **SEC:** **Pin 7 : DC Output +V Pin 9 : DC Output 0V** **==> picture [114 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> (View From Pins Side)<br>**----- End of picture text -----**<br> Revision: 3 Page: 6 of 6 www.myrra.com The information contained in this document is subject to change without notice.
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →