40PC100G1A
Pressure Sensor, Miniature, Amplified, 100 psi, Voltage, Gauge, 5 V, Straight, 10 mA
- Manufacturer: HONEYWELL
- Product type: Pressure Transducers
- Port Style: Straight
- Product Range: 40PC Series
- Sensor Output: Voltage
- Supply Current: 10mA
- Voltage Rating: 5V
- Operating Pressure Max: 100psi
- Pressure Measurement Type: Gauge
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 93.5 € |
| Current stock | 10+ |
| Lead time | 30 days |
## Interactive Catalog Replaces Catalog Pages Honeywell Sensing and Control has replaced the PDF product catalog with the new Interactive Catalog. The Interactive Catalog is a power search tool that makes it easier to find product information. It includes more installation, application, and technical information than ever before. **Click this icon to try the new Interactive Catalog.** 40PC Series ## **Pressure Sensors** Miniature Signal Conditioned ## **FEATURES** Smallest amplified sensor package Minimal PCB space _e Fully signal conditioned -e Operating temperature range from −45 ° to +125 ° C e Silicon piezoresistive technology Monolithic design 6 Pin DIP package e Port designed for O-ring interface e Excellent media compatibility e Accuracy of 0.2% ## **PERFORMANCE CHARACTERISTICS** |Pressure Range||±50 mm Hg|0-15 psi<br>0-100 psi<br>0-150 psi|0-250 psi| |---|---|---|---|---| |Overpressure, max.||±170 mm Hg|45 psi<br>200 psi<br>300 psi|500 psi| |Supply Voltage|||5 VDC±0.25|| |Supply Current<br>10 mA max.<br>Output Source Current<br>0.5 mA max.<br>Output Sink Current<br>1.0 mA max.<br>Operating Temperature<br>−45°to+125°C (−49°to+257°F)<br>~~a~~<br>~~a~~||||| |Storage Temperature|||−55°to+125°C (−67°to+257°F)|| |Hysteresis & Repeatability|||0.15% Span, Typ.|| |Ratiometricity (at 4.75 to||||| |5.25 Supply Voltage)|||±0.25% Span, Typ.|| |Output Load Capacitance|||0.05 microtarads, max.|| |Full Scale||||| |−50 mm Hg|||0.50 VDC Typ.|| |+50 mm Hg|||4.50 VDC Typ.|| |All other pressure ranges|||4.50 VDC Typ.|| |Media|||DRY GASES ONLY: Media must be compatible with|| |Compatibility|P1 port||epoxy based adhesive|| ||||Media must be compatible with glass, silicon,|| ||P2 port||stainless steel, invar, Sn/Ni plating or Sn/Ag solder|| ## **40PC SERIES ORDER GUIDE** |**40PC SERIES ORDER GUIDE**|||| |---|---|---|---| |**Catalog**<br>**Listing**|**Pressure Range**<br>**psi**|**Pressure**<br>**Type**|**Lead Style**| |40PC001B1A<br>~~a~~|±50 mm Hg|Bi-directional|1-unformed| |40PC001B2A<br>~~a~~<br>~~Ge~~|±50 mm Hg<br>~~Ge~~<br>~~(~~|Bi-directional<br>~~Ge~~|2-formed away from port<br>~~Ge~~| |40PC001B3A<br>~~Rs~~|±50 mm Hg<br>~~Rs~~<br>~~(~~|Bi-directional<br>~~Rs~~|3-formed towards port<br>~~Rs~~| |40PC015G1A<br>~~RR~~<br>~~(~~|0-15<br>~~(~~<br>~~(~~|Gage|1-unformed| |40PC015G2A<br>~~RR~~<br>~~(~~<br>~~a~~<br>~~(~~|0-15<br>~~(~~<br>~~(~~|Gage|2-formed away from port| |40PC015G3A<br>~~RR~~<br>~~(~~<br>~~a~~<br>~~(~~<br>~~a~~|0-15<br>~~(~~<br>~~(~~|Gage|3-formed towards port| |40PC100G1A<br>~~a~~<br>~~(~~<br>~~a~~<br>~~I~~|0-100<br>~~(~~|Gage|1-unformed| |40PC100G2A<br>~~a~~<br>~~I~~<br>~~RR~~|0-100|Gage|2-formed away from port| |40PC100G3A<br>~~I~~<br>~~RR~~|0-100|Gage|3-formed towards port| |40PC150G1A<br>~~RR~~<br>~~I~~|0-150<br>|Gage|1-unformed| |40PC150G2A<br>~~I~~|0-150<br>|Gage|2-formed away from port| |40PC150G3A<br>~~I (~~<br>~~ER~~<br>~~(~~|0-150<br>~~(~~<br>~~(~~|Gage|3-formed towards port| |40PC250G1A<br>~~(~~<br>~~ER~~<br>~~(~~|0-250<br>~~(~~<br>~~(~~|Gage|1-unformed| |40PC250G2A<br>~~ER~~<br>~~(~~<br>~~(~~|0-250<br>~~(~~<br>~~(~~|Gage|2-formed away from port| |40PC250G3A<br>~~(~~<br>~~a~~|0-250<br>~~(~~|Gage|3-formed towards port| **Note:** For tubing and O-Ring interface recommendations, see the 40PC Application Note in the Reference Section. Honeywell e Sensing and Control e 1-800-537-6945 USA e+ 1-815-235-6847 International e 1-800-737-3360 Canada **31** 40PC Series ## **Pressure Sensors** Miniature Signal Conditioned ## **OUTPUT PERFORMANCE CHARACTERISTICS @ 25** ° **C, 5VDC (unless otherwise noted)** |**Linearity,**<br>**Pressure**<br>**Null**<br>**Span**<br>**Sensitivity,**<br>**B.F.S.L.**<br>**Range**<br>**(VDC)**<br>**(VDC)**<br>**Typ.**<br>**(% Span) Max.**|**Null Shift**<br>**Span ShIft**<br>**Combined Null**<br>**(% Span)**<br>**(% Span)**<br>**and Span Shift**<br>**Max.**<br>**Max.**<br>**(% Span) Max.**| |---|---| |±**50 mm Hg**<br>2.50±0.050<br>4.00 Typ.<br>40.0 mV/mm Hg 0.80|+25°to+50°C<br>±1.50<br>±1.50<br>—| ||+25°to 0°C<br>±1.50<br>±1.50<br>—| |**0 to 15 psi**<br>0.50±0.11<br>4.00±0.11<br>266.6 mV/psi<br>0.20|+25°to−18°C<br>±2.00<br>±0.75<br>±2.00| ||+25°to+63°C<br>±2.00<br>±0.75<br>±2.00| ||+25°to−45°C<br>±2.75<br>±1.00<br>±3.00| ||+25°to+85°C<br>±2.75<br>±1.00<br>±3.00| ||+25°to+125°C<br>—<br>—<br>—| |**0 to 100 psi**<br>0.50±0.04<br>4.00±0.09<br>40.0 mV/psi<br>0.10|+25°to−18°C<br>±1.25<br>±0.75<br>±1.50| ||+25°to+63°C<br>±1.25<br>±0.75<br>±1.50| ||+25°to−45°C<br>±2.00<br>±1.00<br>±2.50| ||+25°to+85°C<br>±2.00<br>±1.00<br>±2.50| ||+25°to+125°C<br>±3.00<br>±2.00<br>±3.00| |**0 to 150 psi**<br>0.50±0.04<br>4.00±0.07<br>26.6 mV/psi<br>0.10|+25°to−18°C<br>±0.75<br>±0.75<br>±0.75| ||+25°to+63°C<br>±0.75<br>±0.75<br>±0.75| ||+25°to−45°C<br>±1.00<br>±1.00<br>±1.00| ||+25°to+85°C<br>±1.00<br>±1.00<br>±1.00| ||+25°to+125°C<br>±1.50<br>±1.50<br>±1.50| |**0 to 250 psi**<br>0.50±0.04<br>4.00±0.07<br>16.0 mV/psi<br>0.10|+25°to−18°C<br>±0.75<br>±0.75<br>±0.75| ||+25°to+63°C<br>±0.75<br>±0.75<br>±0.75| ||+25°to−45°C<br>±1.00<br>±1.00<br>±1.00| ||+25°to+85°C<br>±1.00<br>±1.00<br>±1.00| ||+25°to+125°C<br>±2.00<br>±2.00<br>±3.00| ## **PERFORMANCE SPECIFICATIONS, TEMPERATURE/ACCURACY** |**Temperature**<br>**Range**|**Total Accuracy (% Span) Max.**| |---|---| ||**0 to 15 psi**<br>**0 to 100 psi**<br>**0 to 150 psi**<br>**0 to 250 psi**| |25°C|±0.4 (RSS)<br>±0.2 (RSS)<br>±0.2 (RSS)<br>±0.2 (RSS)| |−18°to+63°C|±4.0<br>±2.5<br>±2.0<br>±2.0| |−45°to+85°C|±4.0<br>±2.5<br>±2.0<br>±2.0| |−45°to+125°C|±3.0<br>±2.5<br>±3.0| **Note 1:** Accuracy at 25 ° C is defined as RSS error for linearity, hysteresis, and repeatability. - **Note 2:** Total accuracy is the maximum deviation from the 25 ° C reference transfer function at any pressure or temperature over the specified ranges. This calculation includes null, span, linearity, hysteresis, repeatability, null shift, and span shift. Honeywell � Sensing and Control � 1-800-537-6945 USA ��1-815-235-6847 International � 1-800-737-3360 Canada **32** 40PC Series ## **Pressure Sensors** Miniature Signal Conditioned ## **ELECTRICAL CONNECTION** ## **MOUNTING DIMENSIONS** (for reference only) mm/In. ## **NOTES:** 1. Square corner marks pin 1 (Vs). 2. Output is short circuit protected. ## **NOTE:** **==> picture [52 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Lead Style 1<br>**----- End of picture text -----**<br> **==> picture [11 x 46] intentionally omitted <==** **----- Start of picture text -----**<br> Amplified<br>**----- End of picture text -----**<br> P1 - DRY GASES ONLY: Media must be compatible with epoxy based adhesive. P2 - Media must be compatible with glass, silicon, stainless steel, invar, Sn/Ni plating or Sn/Ag solder. ## **Lead Style 2** ## **Lead Style 3** Honeywell e Sensing and Control e 1-800-537-6945 USA e+ 1-815-235-6847 International e 1-800-737-3360 Canada **33**
Updated at February 9, 2023
Honeywell is a globally recognized leader in the design and manufacture of advanced sensing and switching solutions. Renowned for engineering components that deliver enhanced precision and ruggedness, Honeywell provides essential technologies for demanding applications across critical healthcare, aerospace, and industrial equipment. With a comprehensive portfolio built to address both basic and complex design challenges, the company stands at the forefront of reliable electronic component manufacturing. The core of our Honeywell offering is an extensive selection of high-performance sensors and transducers. This includes a robust lineup of pressure sensors and transducers engineered for accurate fluid and gas measurement in challenging environments. Furthermore, we provide a wide array of temperature sensors and specialized temperature sensing NTC thermistors designed for stable thermal management, alongside precision current sensors and load cells that deliver critical feedback for control systems. Beyond advanced sensing technology, Honeywell’s expertise extends to essential circuit protection and electromechanical components. Our selection encompasses power relays, thermal magnetic circuit breakers, and standard terminal blocks, ensuring safe and efficient power distribution. Whether integrating core components or sourcing specialized accessories, design engineers can rely on Honeywell for uncompromising quality and operational excellence.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →