4040300000
Battery Charger, LiFePO4, 8 Cell, 29.2V, 4A, Desktop, 90-264 VAC, IEC 60320 C8, 4040 LiFe Series
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MASCOT
- Product type:
- SVHC: No SVHC (27-Jun-2024)
- Plug Type: IEC 60320 C8
- Product Range: 4040 LiFe Series
- Charge Current: 4A
- Output Voltage: 29.2V
- Supply Voltage: 264VAC
- Battery Size Code: -
- Battery Charger Type: Desktop
- No. of Cells Charged: 8 Cells
- Battery Technologies Supported: LiFePO4
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 152.31 € |
| Current stock | 10+ |
| Lead time | 30 days |
## Model 4040 LiFe 8 A max out • 90-264 VAC input Universal input voltage 90-264 VAC 2-pin IEC 60320 C8, 3-pin C6 on request NTC input on request —
~~@~~
PO Box 177 • 1601 Fredrikstad NORWAY • sales@mascot.no • www.mascot.no
3-step charge control with current detection and timer
- Universal input voltage 90-264 VAC
- 2-pin IEC 60320 C8, 3-pin C6 on request
- Output terminal: Battery clips, DC conn., push-on terminals or open ends Temp. compensation of charge voltage
Available versions 4 cell / 8A 8 cell / 4A 10 cell / 3,2A 11 cell / 2,9A 12 cell / 2,65A 16 cell / 2A
On request
Wake up and low current start-up of deeply discharged battery packs Safety indication and protection: against reverse polarity, short circuit, charging battery packs with the wrong number of cells and safety timer runout
Active power factor correction
Approvals:
## - Medically certified
Safety: EN 60601-1 ed. 3.1 and ed. 3.2
Home healthcare EN 60601-1-11
EMC: EN 60601-1-2 ed. 4
## - UL approved
Custom specifications on request:
Charging parameters, connectors, cords, logo print, housing/open frame/IP rating and certificates. For more information: custom design info sheet
Notes: Desktop unit Wall mount bracket available With active power factor correction 2MOOP standard, 2MOPP available Wall mount bracket available With battery clips and temp sensor Std output cord: L 1.2m, AWG 14, UL 2464
MASCOT ELECTRONICS AS SPECIFICATIONS FOR TYPE 4040 LiFePO4 Chargers PAGE 1 (2) DATE 20.12.21 (versions in grey are on request only)
|MASCOT<br>type 4040|LiFePO, chargers:|4-cell LiFePO,<br>8-cell LiFePO,|4-cell LiFePO,<br>8-cell LiFePO,|||10-cell|10-cell|LiFePO,|LiFePO,|LiFePO,||
|---|---|---|---|---|---|---|---|---|---|---|---|
|(Charge control:<br>Charge|indication:|||||||||||
|Step0 < 10min<br>Yellow||CC500mA+50mA,when battvoltage < 10.5V. | CC350mA+25mA,when battvoltage < 21V. |||(<br>350||nA,|wi|||olt|6.2|
|Step<br>0 > 10min<br>Red|(4 blinks)|0A/0V|0A/0V||||y||)|||
|Step 1 (Constant Current)<br>Step2 (ConstantVoltage)|Yellow<br>.<br>FlashingYellow|CC 8.0A+ 0.2A, when 10.5V<<br>CV 14.6V+0.2V<5.4A until |charge<br>ormax. 1h|<Vbat< 14.6V<br>CC4.0A +0.2A,when 21V < Vbat< 29.2V<br>charge<450mA| CV29.2V+0.2V<2.8A until<br>|charge <350mA<br>9<br>or max. 1h.<br>9|Vv<br>‘)|A|+ 0.2A,<br>i|w<br>orn||VV<br>ti<br>1|<V<br>are|E<br>350r|
|Charge timer (step2, CV)||th|th|||||!||||
|Safety timer (all steps)|Red<br>(5 blinks)|72h|72h|||||J||||
|Step 3 Float charge voltage|Green|14.0V + 0.2V|28.0V + 0.2V||||3.0V|+|0.2\|||
|Restart voltage||13.2V|26.4V||||||)|||
|,<br>,|||0—45 °C: Normal charge.|||||||||
|Ripples<br>00Mpp||||||||||||
||||Protected against reversed polarity. Error Indication: Red (2|blinks)||||||||
||||Short circuit proof. Error Indication: Red (3 blinks)|||||||||
|Protection:<br>.||Charging ofwrong lowervoltage batterypack will belimited to500mA(350mAat8and <br>Indication: Red (4 blinks)||10cell)andterminated||terminated||after10min.||||
||||Safety timer. Error Indication: Red (5 blinks)|||||||||
|||No charge|(or charge terminated)<br>if connecting wrong battery<br>pack with higher voltage. Indication: LED is|||||OFF.||||
|linputterminal:||pins IEC 320 connector, C8. (3pins IEC 320 connector, C6onrequest)||||||||||
|Weights80d||||||||||||
**==> picture [514 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
MASCOT ELECTRONICS AS SPECIFICATIONS FOR TYPE 4040 Li Chargers PAGE 2 (2)<br>DATE 29.12.2022 (versions in grey are on request only)<br>**----- End of picture text -----**<br>
|MASCOT<br>type 4040|LiFePO, chargers:|LiFePO, chargers:||||11-cell LiFePO.|11-cell LiFePO.|11-cell LiFePO.|||12-cell LiFePO,|16-cell LiFePO,|
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|(Charge control:<br>Charge <br>Step0 < 10min<br>Yellow|indication:||C|200mA|+|25mA, wher||tt<br>voltac|8.6V||C<br>200mA<br>+<br>25mA, when<br>ba**t**<br>voltag<br>31.2V. | CC 200mA|+ 25mA, when batt voltage < 41.6V.|
|Step0 >10min<br>Red<br>Step 1 (ConstantCurrent)<br>Step2 (Constant Voltage)|(4 blinks)<br>Yellow<br>FlashingYellow|Yellow|CV|29<br>40.15V+|tt)<br>0.3V||0A/<br>0V<br>when<br>28.6V <br>6<br>\<br>ti|< Vba<br> | harg|).15V<br>00m|(|0A/0V<br>0A/0V<br>35A + 0.2A,<br>wt<br>1.2V < Vb:<br>43.8<br>CC2.0A+ 0.2A,when 41.6V<Vbat< 58.4V<br>V<br>43.8V + 0.3V<br>1.8<br>‘<br>I charg<br>OOmA<br>|CV58.4V<br>+0.3V<1 AA url | charge <200mA||
|Charge timer (step2, CV)|||||||||||1t|1h|
|Safety timer (all steps)|Red|(5 blinks)|||||7||||2|72h|
|Step 3 Floatcharge voltage|Green||||||3.5V + 0.2V||||OV+<br>0.3V|56.0V+0.3V|
|Restart voltage|||||||5.3V||||9.6V|52.8V|
|-<br>5|||||||||||0-45 °C: Normal charge.||
|Ripples<br>100mpp|||||||||||||
||||||||||Protected against reversed polarity. Error Indication: Red (2 blinks)||||
|||||||||||Short circuit proof. Error Indication: Red (3 blinks)|||
|Protection:<br>-|||||||Charging ofwrong lowervoltagebatterypackwill be limitedto200mAandterminated <br>Indication: Red (4 blinks)|||||after 10min.|
||||||||||||Safety timer. Error Indication: Red (5 blinks)||
||||||||No charge|(orcharge terminated)|||if connecting wrong battery<br>pack with higher voltage. Indication: LED is OFF.||
|Weights80d|||||||||||||
Technical drawing
**==> picture [136 x 162] intentionally omitted <==**
**----- Start of picture text -----**<br>
Nowe<br>.. 43,5mm<br>Ps a<br>i 87mm<br>**----- End of picture text -----**<br>
**==> picture [160 x 27] intentionally omitted <==**
**----- Start of picture text -----**<br>
y @ es ELECTRONICS AS<br>**----- End of picture text -----**<br>
|We, the responsible|manufacturer;||||||
|---|---|---|---|---|---|---|
|Company Name:|Mascot ElectronicsAS||||||
|Postal Address:|P.O.Box 177, N-1601 Fredrikstad, NORWAY||||||
|Visiting Address:|Mosseveien 109, N-1624 Gressvik, NORWAY||||||
|Telephone:|(+47) 69 36 4300<br>E-mail:<br>sales@mascot.com||WEB:|Wwww.mascot.com|||
|declare thatthis Declaration is issued underoursole responsibilityand belongs to the following product(s):|||||||
|Product and|BatteryChargerfor Li-lon-, LiFePO,-, Li-Titanate-, NiIMH/NiCD- or Lead-Acid Batteries||||||
|intended purpose:|||||||
|Brand(s)} :|S)and/orTILAS_GLGE (mayalsocarry additional customername, logoortrademark}||||mark}||
|Type(s)/Model(s)/<br>UDI-DI:|4040<br>2xMOOPto IEC60601-1,ratedinputvoltage 100-240V, 50-60Hz<br>4040vV<br>2xMOOPto IEC60601-1,ratedinputvoltage 100-240V50 Hz/100-220V60Hz||||Hz||
||aoaop<br>2xMOPP to IEC 60601-1, rated input voltage 100- 240V,|V, 50- 60 Hz|||||
||AOQ40VP<br>—-2xMoPP to IEC 60601-1, rated inputvoltage 100- 240V|V50 Hz/ 100-220V60Hz|||Hz||
||4040B<br>2xMOOP to IEC 60601-1, PWB-only,for building-in, rated input||||||
||voltage 100 - 240 V, 50 - 60 Hz||||||
||4040VB<br>2xMOOPto IEC 60601-1, PWB-only,for building-in, rated input||||||
||voltage 100 - 240V50 Hz/ 100 - 220V 60 Hz||||||
||A040BP<br>2xMOPP to IEC 60601-1, PWB-only, for building-in, rated input||||||
||voltage 100 - 240 V, 50 - 60 Hz||||||
||AO40VBP<br>2xMOPP to IEC 60601-1, PWB-only, for building-in, rated input||||||
||voltage 100 - 240V 50 Hz/ 100 - 220V 60 Hz||||||
||{all modelsmay also carry additional customer model name orpartnumber)||||||
|Batch / Serial No./|all CE- and/or UKCA- marked products producedfrom the date indicated below||||||
|UDI-PI:|(for production date: see marking onthe product)||||||
|Description:|Input:<br>max. 1.6A 100-240VAC50-60 Hz, Class | orClass||Class II||||
||Output:||||||
||versions for Lead-Acid Batteries 6 -48V:||||||
||6 V max. 10.0A<br>12V max.8.0A<br>18Vmax.5.3A||24V max. 4.0A|||36 V max. 2.66A|
||48V max. 2.0A||||||
||versions for Li-lon Batteries 1 - 14 cell:||||||
||1cellmax.10.0A<br>2cellmax.10.0A<br>3 cell max.9.0A||4 cell max. 7.0A|||5 cell max.5.6A|
||6 cell max. 4.65A<br>7 cellmax.4.0A<br>8cell max.3.5A||9 cellmax.3.1A||10cell|10cell max.2.8A|
||11 cellmax.2.54A<br>12 cell max.2.33A<br>13 cell max.2.15A||14 cell max.2.0A||||
||versions for LiFePO4 Batteries 1 - 16 cell:||||||
||1cellmax.10.0A<br>2cellmax.10.0A<br>3 cell max. 10.0A||4 cell max. 8.0A|||5 cell max.6.4A|
||6 cell max.5.3A<br>7 cellmax.4.6A<br>8 cell max.4.0A||9 cellmax.3.5A||10cell max.3.2A||
||11 cell max. 2.92A<br>12 cell max. 2.68A 13 cellmax.2.47A||14 cellmax.2.3A||15 cell max. 2.15A||
||16 cell max. 2.0A||||||
||versions for Li-Titanate Batteries 1 - 20 cell:||||||
||1cellmax.10.0A<br>2cellmax.10.0A<br>3cellmax.10.0A|4cell|4cell max. 10.0A|||5 cell max. 8.2 A|
||6 cell max. 6.8A<br>7cellmax.5.9A<br>8cell max.5.1A||9cellmax.4.5A||10cell max.4.1A||
||11 cell max.3.7A<br>12 cell max.3.4A<br>13 cell max.3.17A||14 cell max.2.94A||15 cell max.2.75A||
||16 cellmax.2.57A<br>17 cell max.2.42A<br>18cell max.2.29A||19cell max.2.17A|||20cell max. 2.00|
||versions for NIMH/NiCd Batteries:||||||
||2 cell max. 10.0 A<br>3-6 cell max. 10.0A 4-8 cell max. 8.0A|5-10 cell max. 6.5||A|6-12 cell max. 5.4A||
||10-20 cell max. 3.2 A<br>10-22 cell max.2.9A<br>15-30 cell max. 2.18A<br>20-40 cell max.|||||1.96A|
||NOTES:||||||
||- Forcompliance with EN 60601-1 outputterminals >60VDC must be inaccessible to operatorand||||||
||maynotbeinterconnected.||||||
Page 1 of 4
@7Zza5c0%ss ELECTRONICS AS
## EU & UK Declaration of Conformity
The product(s) described above are in conformity with the relevant European Union harmonisation legislation for CE-marking: 2014/30/EU EU Directive - Electromagnetic Compatibility (EMC) recast, repealing Directives 2004/108/EC & 89/336/EEC (EU) 2017/745 EU Regulation - Medical Devices Regulation (MDR), Risk Class | Device repealing directive 93/42/EEC 2009/125/EC EU Directive - Energy Related Products, Ecodesign (ERP) recast, repealing Directive 2005/32/EC (EUP) 2015/863/EU EU Directive - Restriction on use of Hazardous Substances in EEE ("RoHS3") recast, repealing Directives 2002/95/EC, 2008/35/EC & 2011/65/EU The product(s) described above are in conformity with the relevant U.K. legislation for UKCA-marking: Electrical Equipment (Safety) Regulations 2016 Electromagnetic Compatibility (EMC) Regulations 2016 The Medical Devices (Amendment etc.) (EU Exit) Regulations 2020, Risk Class | Device Ecodesign for Energy-Related Products (External Power Supplies) Regulations 2020 Draft Regulation, awaiting implementation
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012
Page 2 of 4
## y @ es ELECTRONICS AS The following harmonised standards and/or technical specifications have been applied:
{International editions and comments indicated in brackets):
|ElectricalSafetyandElectromagneticCompatibility (to MDR-Directives):|ElectricalSafetyandElectromagneticCompatibility (to MDR-Directives):|ElectricalSafetyandElectromagneticCompatibility (to MDR-Directives):|
|---|---|---|
|EN 60601-1|EN 60601-1:2006 +/AC:2010+/A1:2013/A2:2021<br>Medical electrical equipment, Edition 3.2||
||(IEC 60601-1:2005 +/A1:2012/A2:2020)<br>{Alsotested accordingtoedition 3.1)||
|EN 60601-1-2|EN 60601-1-2:2015|Medical equipment, EMC - Requirements and tests, Edition4.0|
||(IEC 60601-1-2:2014, Edition 4.0}||
|EN 60601-1-11|EN 60601-1-11:2015|Medical equipment, Home Healthcare, Edition 2.0|
||(IEC 60601-1-2:2015/A1:2020, Edition 2.1)||
|ElectromagneticCompatibility (to EMC-Directive):|||
|EN 61000-6-1|EN 61000-6-1:2007|Immunity-residential, comm.& light-industrial environment, Edition 2.0|
||(IEC 61000-6-1:2005, Edition 2.0}(also|(also IEC61000-6-1:2016, Edition3.0, notyetanEN-norm)|
|EN 61000-6-3|EN 61000-6-3:2007 +/A1:2011 &/AC:2012|/AC:2012<br>Emission-residential, comm.& light-industrial environment, Edition 2.1|
||(IEC 61000-6-3:2007 + /A1:2010)||
|Ecodesign to EU ERP-Directive:|||
|Commission Regulation (EC)No2019/1782||implementingDirective2009/125/ECwithregardtoecodesignrequirements forno-<br>load condition electric powerconsumption and average active efficiency ofexternal|
|||powersupplies (Note:notapplicable to Battery Chargers, ref. Article 1.2item c))|
|EcodesignforU.K.:|||
|Draft Regulation only(awaiting|(awaiting implementation)|Draft"EcodesignforEnergy-Related Products(External PowerSupplies)Regulations<br>2020” (Note: not applicable to Battery Chargers)|
|EcodesignforU.S.A. (Note:dependson batteryused !):|||
|USCode of Federal Regulations (CFR)<br>Also called "DoEcompliance”||10CFR Part430 - EnergyConservation ProgramforConsumer Products,<br>10CFR Part430,Subpart B -Test Procedures,<br>10CFR AppendixYto Subpart B of Part430, Uniform Test Method for Measuring|
|||the Energy Consumption ofBattery Chargers or 10 CFRAppendixZto Subpart B of|
|||Part430, Uniform Test Method for Measuringthe Energy Consumption of External|
|||Power Supplies, whichever applicable.|
|California Code of Regulations (CCR)||CCRTitle20 - Public Utilities and Energy,|
|Also called "CEC-400compliance” referring to CEC-400-2017-||Division 2 - State Energy Resources Conservation and Development Commission,|
|002 "2016Appliance Efficiency Regulations” issued by||Chapter 4 - Energy Conservation, Article 4 - Appliance Efficiency Regulations,|
|California Energy Commission||Sections 1601 to 1609|
|Restriction ofthe Useof|ofcertain HazardousSubstances (RoHS)for EU:||
|2015/863/EU “RoHS3”||EU Directive - Restrictiononuse ofHazardous Substances in EEE Restriction ofthe<br>Use of certain Hazardous Substances in Electrical and Electronic Equipment|
|Restriction ofthe Useof|ofcertain HazardousSubstancesfor UK:||
|The Restriction ofthe|Use ofCertain Hazardous Substances in Electrical and Electronic Equipment||
|Regulations2012|||
Page 3 of 4
Mascot AS, PO Box 177 • 1601 Fredrikstad NORWAY • sales@mascot.no • www.mascot.no
Date: Thu Aug 08 2024
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →