Image not available
Illustrative purposes only
4-1415037-1
Relay Socket, PT Series
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: TE CONNECTIVITY / PARTNER STOCK
- Product type: Relay Sockets
- SVHC: No SVHC (27-Jun-2024)
- Product Range: PT Series
| Delivery and price | |
|---|---|
| Units per pack | 150 |
| Price | 2.11 € |
| Current stock | 500+ |
| Lead time | 30 days |
## **ACCESSORIES INDUSTRIAL POWER RELAY RT** ## GENERAL PURPOSE RELAYS ACCESSORIES ## **FEATURES** - For Industrial Power Relay RT pinnings 3.5 mm / 5 mm; relay height 15.7 mm - New retainer clip with ejection function - Easy replacement of relays on a densely packed DIN rail - No reduction of protection class or creepage/clearance with plastic retainer - Simple plug-in indicator- and protection modules - White snap-on marking tags ## **APPROVALS** - VDE Cert. No. 40007571 - cULus E135149 ## Z Technical data of approved types on request ## **PREMIUM SOCKET WITH SCREWLESS TERMINALS FOR DIN RAIL MOUNTING** **RT7872P** RT7872P Premium socket, logical terminal arrangement ## **FEATURES** - Screwless Clamps - Mounting of solid wires without tool - Double Clamps per terminal - Jumper links for interconnection - Logical terminal arrangement ## **APPROVALS** - VDE Cert. No. 40007571 - cULus E135149 ## Z Technical data of approved types on request **Accessories Industrial Power Relay RT** General Purpose Relays Accessories ## **TECHNICAL DATA** |Rated voltage/Max.<br>switching voltage AC|240/400VAC| |---|---| |Rated current|2 x 8 A, 16 A *)| |Dielectric strength<br>coil contact circuit<br>5000 Vrms<br>open contact circuit<br>1000 Vrms<br>adjacent contact<br>circuits<br>2500 Vrms|| |Clearance / creepage<br>coil contact circuit<br>≥10/10 mm|| |Material group of<br>insulation parts|IIIa| |Flammability<br>class UL 94|V-0| |Insulation to IEC 60664-1<br>Type of insulation<br>coil-contact circuit<br>reinforced<br>open contact circuit<br>functional<br>adjacent contact<br>circuits<br>functional|| |Rated insulation<br>voltage|250 V| |Pollution degree|2| |Rated voltage system|230 / 400 V| |Over voltage category|III| |Material compliance:|EU RoHS/ELV, China RoHS,<br>REACH, Halogen content<br>refer to the Product Compliance<br>Support Center at<br>www.te.com/customersupport/<br>rohssupportcenter| |Ambient temperature range<br>for mounting/<br>handling<br>-25 ... +70˚C<br>in operation<br>-40 ... +70˚C|| |Terminals|screwless| |Wire strip length|12 mm| *) For 1 pole relays (16 A) the relay terminals 11-21, 12-22 and 14-24 have to be bridged. Wire cross section 1x0.75/1/1.5mm² solid wire 2x0.75/1mm² with stand. isolation (no 2x1.5mm² oversize isolation) stranded wire 1x0.75/1/1.5mm² without bootlace crimp 2x0.75/1mm² without bootlace crimp 2x1.5mm² with stand. isolation 1x0.75/1mm² with bootlace crimp 2x0.75mm² with bootlace crimp without 1x1.5mm² isolation or min 18 mm long For stranded wires with braids 0.05 mm or smaller the use of bootlace crimps is recommended. When using stranded wires without bootlace crimp the clamp must be opened during insertion. |during insertion.|| |---|---| |Insertion cycles|A (10)| |Max. Insertion<br>Force total|100 N| |Mounting distance|≥0, dense packing| |Weight|36 g| |Packaging unit|10 pcs| ## **DERATING CURVE RT7872P** **==> picture [209 x 177] intentionally omitted <==** Not suitable for bistable relays with 2 coils! INDUSTRIAL AUTOMATION & ELECTRIFICATION /ACCESSORIES INDUSTRIAL POWER RELAY RT 2 **Accessories Industrial Power Relay RT** General Purpose Relays Accessories ## **HOW TO USE, PRECAUTIONS** ## **JUMPER LINK** ## **ACCESSORIES** |||||**ACCESSORIES**|| |---|---|---|---|---|---| |**SOCKET WITH SCREWLESS TERMINALS**||||**ACCESSORIES**|| |**FOR DIN RAIL MOUNTING**||||**FOR RT7872P**|| ||**Type**<br>**Description**<br>**Part Number**<br>~~eee eee~~|||**Type**<br>**Description**<br>**Part Number**<br>~~eee~~|| ||RT7872P|Premium socket, logical terminal<br>arrangement<br>Socket with screwless terminals|1860200-1|RT17017<br>Plastic retaining clip,<br>relay height 15.7 mm|2022103-1| |||pinning 5 mm for DIN rail mounting||RT17040<br>Marking tag|2-1415038-1| ||||||| |||||RT170P1<br>Jumper link, max load 12 A|1860211-1| INDUSTRIAL AUTOMATION & ELECTRIFICATION /ACCESSORIES INDUSTRIAL POWER RELAY RT 3 **Accessories Industrial Power Relay RT** General Purpose Relays Accessories ## **SOCKET WITH SCREW TYPE TERMINALS FOR DIN RAIL MOUNTING** **RT78724** Socket with screw-type terminals, pinning 3.5 mm for DIN rail mounting **RT78726** Socket with screw-type terminals, pinning 5 mm for DIN rail mounting, logical terminal arrangement ## FEATURES - DIN-rail socket with logical setup of connections (input/output) - High quality rising clamp terminals - Captive combination terminal screws - Jumper bars for interconnection ## APPROVALS ## **RT78724 RT78726** - VDE Cert. No. 40017832 - cULus E135149 ## Z **RT78725** Socket with screw-type terminals, conventional terminal arrangement ## FEATURES - Conventional terminal arrangement ## APPROVALS - VDE Cert. No. 40017832 - cULus E135149 ## Z INDUSTRIAL AUTOMATION & ELECTRIFICATION /ACCESSORIES INDUSTRIAL POWER RELAY RT 4 **Accessories Industrial Power Relay RT** General Purpose Relays Accessories ## **TECHNICAL DATA** ||**RT78724/**<br>**RT78726**|**RT78725**| |---|---|---| |Rated voltage/Max.<br>switching voltage AC|240/400VAC|| |Rated current|12A 2 x 8A, 16 A*)|| |Dielectric strength<br>coil-contact circuit<br>5000 Vrms<br>4000 Vrms<br>open contact circuit<br>1000 Vrms<br>1000 Vrms<br>adjacent contact circuits<br>2500 Vrms<br>2500 Vrms||| |Clearance / creepage<br>coil-contact circuit<br>≥10/10 mm<br>≥4.7/4.7 mm||| |Material group of<br>insulation parts|IIIa|| |Flammability class UL 94|V-0|| |Insulation to IEC 60664-1<br>Type of insulation<br>coil-contact circuit<br>Reinforced<br>Basic<br>open contact circuit<br>Functional<br>adjacent contact circuits<br>Functional||| |Rated insulation voltage|250 V|| |Pollution degree|2|| |Rated voltage system|230 / 400 V|| |Rated voltage system<br>Overvoltage category|230 / 400 V<br>III|| |Material compliance|EU RoHS/ELV, China RoHS,<br>REACH, Halogen content<br>refer to the Product<br>Compliance Support Center at<br>www.te.com/customersupport/<br>rohssupportcenter|| |Ambient temperature range<br>for mounting/handling<br>-20...+70 ° C<br>in operation<br>-40...+70 ° C||| |Terminals|screw|| |Terminal screw torque<br>acc. IEC 61984 max.|0.5 Nm<br>0.7 Nm|| |Terminal Screw size|M3|| |Wire strip length|8 mm|| ||**RT78724/**<br>**RT78726**|**RT78725**| |---|---|---| |Wire cross section<br>single wire<br>2 x 2.5 mm2<br>fine wire<br>2 x 2.5 mm2<br>with bootlace crimp<br>(DIN 46228/1)<br>2 x 1.5 mm2||| |Insertion cycles|A (10)|| |Max. Insertion Force total|100 N|| |Mounting distance|≥0, dense packing|| |Weight|36 g|| |Packaging unit|10 pcs|| Not suitable for bistable relays with 2 coils! ## **DERATING CURVE RT78724** ## **DERATING CURVE RT78725** ## **DERATING CURVE RT78726** *) For 1 pole relays (16 A) the relay terminals 11-21, 12-22 and 14-24 have to be bridged. For 1 pole relays (12 A) the relay terminals 11-12-14 have to be connected to the socket terminals 21-12-14. INDUSTRIAL AUTOMATION & ELECTRIFICATION /ACCESSORIES INDUSTRIAL POWER RELAY RT 5 **Accessories Industrial Power Relay RT** General Purpose Relays Accessories ## **MARKING TAGS** - White marking area 15.5 x 6 mm - Snaps on socket in up to 4 positions **==> picture [181 x 94] intentionally omitted <==** **==> picture [186 x 90] intentionally omitted <==** ## **JUMPER BAR** **==> picture [156 x 150] intentionally omitted <==** ## **SOCKET WITH SCREW TYPE TERMINALS FOR DIN RAIL MOUNTING** **==> picture [250 x 19] intentionally omitted <==** **----- Start of picture text -----**<br> Type Description Part Number<br>**----- End of picture text -----**<br> |RT78724|Socket with screw-type<br>terminals, pinning 3.5 mm<br>for DIN rail mounting,|8-1415035-1| |---|---|---| ||logical terminal arrangement|| |RT78726|Socket with screw type<br>terminals, pinning 5 mm<br>for DIN rail mounting,|6-1415035-1| ||logical terminal arrangement|| |RT78725|Socket with screw type<br>terminals, pinning 5 mm for DIN<br>rail mounting, wconventional<br>terminal arrangement|1860306-1| ## **ACCESSORIES FOR FOR RT78724, RT78725, RT78726** **==> picture [265 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Type Description Part Number<br>**----- End of picture text -----**<br> |**Type**<br>**Description**|**Part Number**| |---|---| |RT17017<br>Plastic retaining clip,<br>relay height 15.7 mm|2022103-1| |RT28816<br>Metal retaining clip,<br>relay height 15.7 mm|1415540-8| |RT17040<br>Marking tag|2-1415038-1| |RT170R8<br>Jumper bar, max load 12 A<br>for connection of up<br>to 8 RT sockets|1860517-8| INDUSTRIAL AUTOMATION & ELECTRIFICATION /ACCESSORIES INDUSTRIAL POWER RELAY RT 6 **Accessories Industrial Power Relay RT** General Purpose Relays Accessories ## **LED- AND PROTECTION MODULES** ## **FOR RT7872P, RT78724, RT78725, RT78726** - Easy insertion of module into the socket. - Wiring in parallel to the coil. |**Type**||**Description**|**Part**<br>**Number**| |---|---|---|---| |PTMT00A0|EM09|Protection diode<br>(standard, A1+,A2-)|9-1415036-1| |PTMT00L0|EM01|Protection diode<br>(A1-, A2+)|1415037-1| |PTMU0524|EM02|RC-network 6...60 VAC|1-1415037-1| |PTMU0730|EM03|RC-network<br>110...230 VAC|2-1415037-1| |PTMV0524|EM04|Varistor 24 VAC|3-1415037-1| |PTMV0615|EM13|Varistor 115 VAC|6-1415365-1| |PTMV0730|EM05|Varistor 230 VAC|4-1415037-1| |PTMD0730|EM31|Residual current bypass<br>RC 110…230 VAC|1415037-2| |PTMR0730|EM29|Residual current bypass<br>resistor 110…230 VAC|1-1415539-2| ## **LED** |**Type**|**Description**|**Description**|**Part**<br>**Number**| |---|---|---|---| |PTML0024|EM18|Red LED 6…24 VDC w.<br>prot. diode (std, A1+, A2-)|5-1415036-1| |PTMG0024|EM12|Green LED 6…24 VDC w.<br>prot. diode (std, A1+, A2-)|2-1415036-1| |PTML1024|EM08|Red LED 6…24 VDC w.<br>prot. diode (A1-, A2+)|8-1415036-1| |PTML0060|EM16|Red LED 24…60 VDC w.<br>prot. diode (std, A1+, A2-)|5-1415539-3| |PTMG0060|EM25|Green LED 24…60 VDC w.<br>prot. diode (std, A1+, A2-)|7-1415539-7| |PTML0110|EM19|Red LED 60…110 VDC w.<br>prot. diode (A1+, A2-)|2-1415392-1| |PTMG0110|EM26|Green LED 60…110 VDC<br>w. prot. diode (A1+, A2-)|1-1415539-7| |PTML0220|EM27|Red LED 110…220 VDC w.<br>prot. diode (A1+, A2-)|1-1415539-4| |PTMG0220|EM28|Green LED 110…220 VDC<br>w. prot. diode (A1+, A2-)|1-1415539-6| |PTML0524|EM07|Red LED 6...24 VDC/VAC|6-1415036-1| |PTMG0524|EM11|Green LED 6...24 VDC/VAC|3-1415036-1| |PTML0560|EM14|Red LED 24...60 VDC/VAC|1-1415539-3| |PTMG0560|EM30|Green LED 24...60 VDC/VAC|1-1415539-5| |PTML0730|EM06|Red LED 110...230 VAC|7-1415036-1| |PTMG0730|EM10|Green LED 110...230 VAC|4-1415036-1| ## **RELAY PACKAGES** Complete packages consisting of a relay mounted on a socket: see Relay Package RT INDUSTRIAL AUTOMATION & ELECTRIFICATION /ACCESSORIES INDUSTRIAL POWER RELAY RT 7 ## **Combination of relay and socket, insulation requirements and thermal characteristics** The relay standard IEC 61810-1 has an important impact on the combination of a relay and the respective socket. The relay sockets have to comply with the requirements of IEC 61984 and the insulation requirements of the IEC 61810-1. Even if the socket alone fullfills or exceeds the insulation requirements as clearance/creepage for the relay, the combination of a relay with a socket may reduce the creepage and lead to a lower rated insulation voltage. Hence restrictions for the combination relay-socket may be the consequence, e.g. a reduction of the voltage range or of the pollution degree. Especially for miniature multi-pole relay and respective sockets with small distance between the contact circuits, these restrictions have a big impact. Apart from the insulation properties, the thermal characteristics of the combination relay and socket are of utmost importance (see > ‘Derating curves’). Especially the operations conditions like multiple heat up and cool down cycles could have significant impact on the long-term stability of the contact resistance of the combination contact tulip and terminal, and may thereby cause risk of overheating and fire hazard. It is strongly recommended that such conditions are considered in the design and usage of the device and that the devices are thoroughly tested under real conditions. As sockets from different sources are not directly comparable, the compliance with the technical specification can only be informed for an approved combination relay-socket. As design details and characteristics for non TE products are beyond our control, confirmations for technical parameters and characteristics regarding such combinations is not possible. Risks as reduced dielectric strenght, fire hazard, etc. due to use based on unclear or omitted data, limitations or restrictions must not be underestimated. NOTE: We only confirm the characteristics and parameters for the approved combinations of relays and sockets as indicated in the catalog and datasheets. ## **Important Notes:** 1. Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. 2. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions. 3. Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change ## **te.com** ©2025 TE Connectivity plc. family of companies. All Rights Reserved. TE Connectivity, TE connectivity (logo) and Every Connection Counts are trademarks owned or licensed by the TE Connectivity plc. family of companies. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. While TE has made every reasonable effort to ensure the accuracy of the information in this document, TE does not guarantee that it is error-free, nor does TE make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE reserves the right to make any changes to the information contained herein without prior notice. TE Connectivity assumes only those obligations set forth in the terms and conditions for this product and shall in no event be liable for any incidental, indirect, or consequential damages arising out of the sale, resale, use, or misapplication of the product. TE expressly disclaims any implied warranties with respect to the information contained herein, including, but not limited to, implied warranties of merchantability or fitness for a particular purpose. Dimensions, specifications and/or information contained herein are for reference purposes only and are subject to change without notice. Consult TE for the latest dimensions, specifications and/or information. Users of TE Connectivity products must make their own assessment as to whether the respective product is suitable for the respective desired application. 11/25 ED INDUSTRIAL AUTOMATION & ELECTRIFICATION /ACCESSORIES INDUSTRIAL POWER RELAY RT
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →