Image not available
Illustrative purposes only
3VA2140-5MQ36-0AA0
Electronic Circuit Breaker, MCCB, 3VA2, 3P, 55 kA, 415 V, 40 A, Without Auxiliary Contact
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Electronic Circuit Breakers
- SVHC: To Be Advised
- Trip Time: -
- No. of Poles: 3 Pole
- Product Range: SENTRON 3VA2 Series
- Current Rating: 40A
- Supply Voltage: 690V
- Load Current Max: -
- Circuit Breaker Mounting: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1284.12 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3VA2140-5MQ36-0AA0**
**Data sheet**
circuit breaker 3VA2 IEC Frame 160 breaking capacity class M Icu=55 kA @ 415 V 3-pole, motor protection ETU860M, LSIG, In=40 A overload protection Ir=16 A...40 A short-circuit protection Isd=1.2..15x In, Ii=3..15x In ground-fault protection, can be switched off Ig=0.4... 1 x In, tg=0.05-0.8s terminal connection
## **Model**
|product brand name|SENTRON|
|---|---|
|product designation|Molded case circuit breaker|
|design of theproduct|Motorprotection|
|design of the overcurrent release|ETU860M|
|protection function of the overcurrent release|LSIG|
|number of poles|3|
|**General technical data**||
|insulation voltage / rated value|800 V|
|operatingvoltage / at AC / rated value|690 V|
|operating power / at AC-3 / at 400 V|18 500 W|
|operating power / at AC-3 / at 230 V|11 000 W|
|power loss[W]/ maximum|1.6 W|
|power loss [W] / for rated value of the current / at AC / in hot|0.53 W|
|operatingstate /perpole||
|mechanical service life(operatingcycles)/ typical|25 000|
|electrical endurance(operatingcycles)/ at AC-1 / at 380/415 V|14 000|
|electrical endurance(operatingcycles)/ at AC-1 / at 690 V|9 800|
|electrical endurance(operatingcycles)/ at AC-3 / at 380/415 V|10 000|
|product feature / for neutral conductors / upgradable/retrofittable|No|
|/ short-circuit and overloadproof||
|ground-fault monitoringversion|Summation current formation L-conductor|
|product function||
|● communication function|Yes|
|●phase failure detection|Yes|
|● other measurement function|Yes|
|Net Weight|2.5 kg|
|**Current**||
|operational current||
|● at 40 °C|40 A|
|● at 45 °C|40 A|
|● at 50 °C|40 A|
|● at 55 °C|40 A|
|● at 60 °C|40 A|
|● at 65 °C|40 A|
|● at 70 °C|40 A|
3VA21405MQ360AA0 Page 1/6
Subject to change without notice © Copyright Siemens
6/4/2026
|**Switching capacity according to IEC 60947**|**Switching capacity according to IEC 60947**|
|---|---|
|switchingcapacityclass of the circuit breaker|E|
|maximum short-circuit current breakingcapacity (Icu)||
|● at 240 V|85 kA|
|● at 415 V|55 kA|
|● at 440 V|55 kA|
|● at 500 V|36 kA|
|● at 690 V|3 kA|
|operatingshort-circuit current breakingcapacity (Ics)||
|● at 240 V|85 kA|
|● at 415 V|55 kA|
|● at 440 V|55 kA|
|● at 500 V|36 kA|
|● at 690 V|2.5 kA|
|short-circuit current makingcapacity (Icm)||
|● at 240 V|187 kA|
|● at 415 V|121 kA|
|● at 440 V|121 kA|
|● at 500 V|75.5 kA|
|● at 690 V|3.7 kA|
|**Adjustable parameters**||
|product feature / for L-tripping/ can be switched on/off|No|
|adjustable response value setting current (Ir) / of the L-trip / with<br>I2t characteristic||
|● minimum|16 A|
|● maximum|40 A|
|adjustable response value delay time (tr) / for L-tripping / with I2t<br>characteristic||
|● minimum|3 s|
|● maximum|30 s|
|adjustable response value setting current (Isd) / of S-trip / with<br>I0t characteristic||
|● minimum|48 A|
|● maximum|600 A|
|adjustable response value delay time (tsd) / for S-tripping / with<br>I0t characteristic||
|● minimum|0.03 s|
|● maximum|0.03 s|
|adjustable response value settingcurrent(Ii)/ for I-tripping||
|● minimum|120 A|
|● maximum|600 A|
|adjustable current response value current / for G-tripping / with<br>standard characteristic||
|● initial value|8 A|
|● full-scale value|40 A|
|adjustable response value delay time (tg) / for G-tripping / with<br>I0t characteristic||
|● minimum|0.05 s|
|● maximum|0.8 s|
|adjustable response value setting current (Ig) / for G-tripping /<br>with I2t characteristic||
|● minimum|8 A|
|● maximum|40 A|
|adjustable response value delay time (tg) / for G-tripping / with<br>I2t characteristic||
|● minimum|0.05 s|
|● maximum|0.8 s|
|adjustable settingcurrent(InN)/ for N-tripping||
|● minimum|0 A|
|● maximum|0 A|
|product function / grounding protection|Yes|
3VA21405MQ360AA0 Page 2/6
Subject to change without notice © Copyright Siemens
6/4/2026
**==> picture [512 x 551] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|adjustable trip class (Tc CLASS)|10A, 10/10E, 20/ 20E, 30/30E|
|tripping time (Tp) / with adjustable trip class (Tc CLASS)|
|● minimum|3 s|
|● maximum|30 s|
|a|Mechanical Design|
|product component|
|● undervoltage release|No|
|● voltage trigger|No|
|● trip indicator|No|
|height [in]|7.13 in|
|height|181 mm|
|width [in]|4.13 in|
|type of connectable conductor cross-sections / of the round|1 x (6 - 120 mm²)|
|conductor terminal / stranded|
|width|105 mm|
|depth [in]|3.39 in|
|depth|86 mm|
|Connections|
|arrangement of electrical connectors / for main current circuit|Front terminal|
|type of electrical connection / for main current circuit|double-sided box terminal|
|design of the surface / of the connections / on the top of the|tin|
|switch (N, 1, 3, 5)|
|design of the surface / of the connections / on the bottom of the|tin|
|switch (N, 2, 4, 6)|
|nn|Auxiliary circuit|
|number of CO contacts / for auxiliary contacts|0|
|Accessories|
|a|
|product extension / optional / motor drive|Yes|
|Environmental conditions|
|a|
|protection class IP / on the front|IP40|
|ambient temperature|
|● during operation / minimum|-25 °C|
|● during operation / maximum|70 °C|
|● during storage / minimum|-40 °C|
|● during storage / maximum|80 °C|
|Environmental footprint|
|a|
|global warming|potential [CO2 eq] / total|61.814 kg|
|global warming|potential [CO2 eq] / during manufacturing|14.6 kg|
|global warming|potential [CO2 eq] / during operation|48.9 kg|
|global warming|potential [CO2 eq] / after end of life|-2.2 kg|
|—____—+__§_—|Siemens Eco Profile (SEP)|Siemens EcoTech|
|reference code / according to IEC 81346-2|Q|
|Approvals / Certificates|
|General Product Approval|
**----- End of picture text -----**<br>
**General Product Approval**
**Maritime application**
**==> picture [320 x 160] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|EA|Miscellaneous|L|_|Confirmation|
|EMV|Test Certificates|
|Special Test Certific-|Miscellaneous|Type Test Certific-|
|@|OO|ate|SO|OT|ates/Test Report|
|other|
**----- End of picture text -----**<br>
3VA21405MQ360AA0 Page 3/6
Subject to change without notice © Copyright Siemens
6/4/2026
CCS (China ClassificaMiscellaneous Miscellaneous Confirmation tion Society)
**other Dangerous goods Environment** Transport Information Environmental ConEnvironmental Conaan)QC PASS ~~———- ———-~~ firmations ~~——-_~~ firmations EPD—*& tare ©@ ~~|~~ **Further information Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/lowvoltage/catalogs **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3VA2140-5MQ36-0AA0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3VA2140-5MQ36-0AA0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)** https://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VA2140-5MQ36-0AA0 **CAx-Online-Generator** https://www.siemens.com/cax **Tender specifications** https://www.siemens.com/specifications **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no>
3VA21405MQ360AA0 Page 4/6
Subject to change without notice © Copyright Siemens
6/4/2026
**==> picture [232 x 330] intentionally omitted <==**
**----- Start of picture text -----**<br>
-Q<br>ELr _ _ _ oe ETU860M<br>L<br>I> S<br>sc { o is} | RE<br>I>> I<br>I> I> I><br>7|[<br>G<br>I>> I>> I>><br>- P MF<br>I>> I>> I>><br>oe<br>7 |||<br>|<br>i |<br>||<br>“|<br>EFB RCD<br>l le || 7<br>1 3 5<br>2 4 6 -X2 -X3<br>**----- End of picture text -----**<br>
**last modified:**
4/23/2026
3VA21405MQ360AA0 Page 5/6
Subject to change without notice © Copyright Siemens
6/4/2026
3VA21405MQ360AA0 Page 6/6
Subject to change without notice © Copyright Siemens
6/4/2026
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →