3VA2110-5MQ36-0AA0
Electronic Circuit Breaker, MCCB, 3VA2, 3P, 55 kA, 415 V, 100 A, Without Auxiliary Contact
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Electronic Circuit Breakers
- SVHC: To Be Advised
- Trip Time: -
- No. of Poles: 3 Pole
- Product Range: SENTRON 3VA2 Series
- Current Rating: 100A
- Supply Voltage: 690V
- Load Current Max: -
- Circuit Breaker Mounting: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1387.65 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3VA2110-5MQ36-0AA0**
**Data sheet**
|Siemens~~@~~<br>EcoTech|circuit breaker 3VA2 IEC Frame 160 breaking capacity class M Icu=55 kA @ 415 V<br>3-pole, motor protection ETU860M, LSIG, In=100 A overload protection Ir=40<br>A...100 A short-circuit protection Isd=1.2..15x In, Ii=3..15x In ground-fault<br>protection, can be switched off Ig=0.2...1 x In, tg=0.05-0.8s terminal connection|
|---|---|
|**Model**||
|product brand name|SENTRON|
|product designation|Molded case circuit breaker|
|design of theproduct|Motorprotection|
|design of the overcurrent release|ETU860M|
|protection function of the overcurrent release|LSIG|
|number of poles|3|
|**General technical data**||
|insulation voltage / rated value|800 V|
|operatingvoltage / at AC / rated value|690 V|
|operating power / at AC-3 / at 400 V|55 000 W|
|operating power / at AC-3 / at 230 V|30 000 W|
|power loss[W]/ maximum|10 W|
|power loss [W] / for rated value of the current / at AC / in hot<br>operatingstate /perpole|3.33 W|
|mechanical service life(operatingcycles)/ typical|25 000|
|electrical endurance(operatingcycles)/ at AC-1 / at 380/415 V|14 000|
|electrical endurance(operatingcycles)/ at AC-1 / at 690 V|9 800|
|electrical endurance(operatingcycles)/ at AC-3 / at 380/415 V|5 000|
|product feature / for neutral conductors / upgradable/retrofittable<br>/ short-circuit and overloadproof|No|
|ground-fault monitoringversion|Summation current formation L-conductor|
|product function||
|● communication function|Yes|
|●phase failure detection|Yes|
|● other measurement function|Yes|
|Net Weight|2.318 kg|
|**Current**||
|operational current||
|● at 40 °C|100 A|
|● at 45 °C|100 A|
|● at 50 °C|100 A|
|● at 55 °C|100 A|
|● at 60 °C|100 A|
|● at 65 °C|100 A|
|● at 70 °C|100 A|
|**Switching capacity according to IEC 60947**||
|switchingcapacityclass of the circuit breaker|E|
|maximum short-circuit current breakingcapacity (Icu)||
|● at 240 V|85 kA|
|● at 415 V|55 kA|
|● at 440 V|55 kA|
|● at 500 V|36 kA|
|● at 690 V|3 kA|
|operatingshort-circuit current breakingcapacity (Ics)||
|● at 240 V|85 kA|
|● at 415 V|55 kA|
|● at 440 V|55 kA|
3VA21105MQ360AA0 Page 1/5
Subject to change without notice © Copyright Siemens
5/31/2026
|● at 500 V|36 kA|
|---|---|
|● at 690 V|2.5 kA|
|short-circuit current makingcapacity (Icm)||
|● at 240 V|187 kA|
|● at 415 V|121 kA|
|● at 440 V|121 kA|
|● at 500 V|75.5 kA|
|● at 690 V|3.7 kA|
|**Adjustable parameters**||
|product feature / for L-tripping/ can be switched on/off|No|
|adjustable response value setting current (Ir) / of the L-trip / with<br>I2t characteristic||
|● minimum|40 A|
|● maximum|100 A|
|adjustable response value delay time (tr) / for L-tripping / with I2t<br>characteristic||
|● minimum|3 s|
|● maximum|25 s|
|adjustable response value setting current (Isd) / of S-trip / with<br>I0t characteristic||
|● minimum|120 A|
|● maximum|1 500 A|
|adjustable response value delay time (tsd) / for S-tripping / with<br>I0t characteristic||
|● minimum|0.03 s|
|● maximum|0.03 s|
|adjustable response value settingcurrent(Ii)/ for I-tripping||
|● minimum|300 A|
|● maximum|1 500 A|
|adjustable current response value current / for G-tripping / with<br>standard characteristic||
|● initial value|20 A|
|● full-scale value|100 A|
|adjustable response value delay time (tg) / for G-tripping / with<br>I0t characteristic||
|● minimum|0.05 s|
|● maximum|0.8 s|
|adjustable response value setting current (Ig) / for G-tripping /<br>with I2t characteristic||
|● minimum|20 A|
|● maximum|100 A|
|adjustable response value delay time (tg) / for G-tripping / with<br>I2t characteristic||
|● minimum|0.05 s|
|● maximum|0.8 s|
|adjustable settingcurrent(InN)/ for N-tripping||
|● minimum|0 A|
|● maximum|0 A|
|product function /grounding protection|Yes|
|adjustable tripclass(Tc CLASS)|10A, 10/10E, 20/ 20E, 30/30E|
|trippingtime(Tp)/ with adjustable tripclass(Tc CLASS)||
|● minimum|3 s|
|● maximum|25 s|
|**Mechanical Design**||
|product component||
|● undervoltage release|No|
|● voltage trigger|No|
|● tripindicator|No|
|height[in]|7.13 in|
|height|181 mm|
|width [in]|4.13 in|
3VA21105MQ360AA0 Page 2/5
Subject to change without notice © Copyright Siemens
5/31/2026
|type of connectable conductor cross-sections / of the round|type of connectable conductor cross-sections / of the round||1 x (6 - 120 mm²)|1 x (6 - 120 mm²)|1 x (6 - 120 mm²)|||
|---|---|---|---|---|---|---|---|
|conductor terminal / stranded||||||||
|width|||105 mm|||||
|depth[in]<br>~~re~~|||3.39 in|||||
|depth|||86 mm|||||
|**Connections**||||||||
|arrangement of electrical connectors / for main current circuit|||Front terminal|||||
|type of electrical connection / for main current circuit|||double-sided box terminal|||||
|design of the surface / of the connections / on the top of the|||tin|||||
|switch(N, 1, 3, 5)||||||||
|design of the surface / of the connections / on the bottom of the|||tin|||||
|switch(N, 2, 4, 6)||||||||
|**Auxiliary circuit**<br>~~ee~~||||||||
|number of CO contacts / for auxiliarycontacts|||0|||||
|**Accessories**<br>~~ee~~||||||||
|product extension / optional / motor drive|||Yes|||||
|**Environmental conditions**<br>~~ee~~||||||||
|protection class IP / on the front|||IP40|||||
|ambient temperature||||||||
|● duringoperation / minimum|||-25 °C|||||
|● duringoperation / maximum|||70 °C|||||
|● duringstorage / minimum|||-40 °C|||||
|● duringstorage / maximum|||80 °C|||||
|**Environmental footprint**<br>~~ee~~||||||||
|global warming potential[CO2 eq]/ total|||61.814 k||61.814 kg|||
|global warming potential[CO2 eq]/ duringmanufacturing|||14.6 kg|||||
|global warming potential[CO2 eq]/ duringoperation|||48.9 kg|||||
|global warming potential[CO2 eq]/ after end of life|||-2.2 kg|||||
|Siemens Eco Profile(SEP)<br>~~re~~|||Siemens EcoTech|||||
|**reference code / according to IEC 81346-2**|||Q|||||
|**Approvals / Certificates**||||||||
|**General Product Approval**||||||||
||Miscellaneous<br>~~EB~~L||||||Confirmation<br>~~_~~|
|**General Product Approval**|**EMV**||||**Test Certificates**|||
|UK<br>ca<br>S€|@||||Miscellaneous<br>Special Test Certific-<br>ate<br>Type Test Certific-<br>ates/Test Report<br>~~Oa~~|||
|**Maritime application**|||||**other**|||
||CCS (China Classifica-||||Miscellaneous|Miscellaneous|Confirmation|
||tion Society)|||||||
|Preerrae||||||||
|**other**<br>**Dangerous goods**|**Environment**|||||||
|Transport Information|Environmental Con-|||||Environmental Con-||
||firmations|||||firmations||
3VA21105MQ360AA0 Page 3/5
Subject to change without notice © Copyright Siemens
5/31/2026
**Further information Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/lowvoltage/catalogs **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3VA2110-5MQ36-0AA0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3VA2110-5MQ36-0AA0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)** https://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VA2110-5MQ36-0AA0 **CAx-Online-Generator** https://www.siemens.com/cax **Tender specifications** https://www.siemens.com/specifications **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no>
**==> picture [203 x 225] intentionally omitted <==**
3VA21105MQ360AA0 Page 4/5
Subject to change without notice © Copyright Siemens
5/31/2026
**==> picture [232 x 330] intentionally omitted <==**
**----- Start of picture text -----**<br>
-Q<br>ELr _ _ _ oe ETU860M<br>L<br>I> S<br>sc { o is} | RE<br>I>> I<br>I> I> I><br>7|[<br>G<br>I>> I>> I>><br>- P MF<br>I>> I>> I>><br>oe<br>7 |||<br>|<br>i |<br>||<br>“|<br>EFB RCD<br>l le || 7<br>1 3 5<br>2 4 6 -X2 -X3<br>**----- End of picture text -----**<br>
**last modified:**
4/23/2026
3VA21105MQ360AA0 Page 5/5
Subject to change without notice © Copyright Siemens
5/31/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →