Image not available
Illustrative purposes only
3VA2110-5MP32-0AA0
Electronic Circuit Breaker, MCCB, 3VA2, 3P, 55 kA, 415 V, 100 A, Without Auxiliary Contact
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Electronic Circuit Breakers
- SVHC: To Be Advised
- Trip Time: -
- No. of Poles: 3 Pole
- Product Range: SENTRON 3VA2 Series
- Current Rating: 100A
- Supply Voltage: 690V
- Load Current Max: -
- Circuit Breaker Mounting: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 930.9 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3VA2110-5MP32-0AA0** **Data sheet** circuit breaker 3VA2 IEC Frame 160 breaking capacity class M Icu=55 kA @ 415 V 3-pole, motor protection ETU550M, LSI, In=100 A overload protection Ir=40 A ...100 A short-circuit protection Isd=1.2... 15x In,Ii=3..15x In nut keeper kit |**Model**|| |---|---| |product brand name|SENTRON| |product designation|Molded case circuit breaker| |design of theproduct|Motorprotection| |design of the overcurrent release|ETU550M| |protection function of the overcurrent release|LSI| |number of poles|3| |**General technical data**|| |insulation voltage / rated value|800 V| |operatingvoltage / at AC / rated value|690 V| |operating power / at AC-3 / at 400 V|55 000 W| |operating power / at AC-3 / at 230 V|30 000 W| |power loss[W]/ maximum|10 W| |power loss [W] / for rated value of the current / at AC / in hot|3.33 W| |operatingstate /perpole|| |mechanical service life(operatingcycles)/ typical|25 000| |electrical endurance(operatingcycles)/ at AC-1 / at 380/415 V|14 000| |electrical endurance(operatingcycles)/ at AC-1 / at 690 V|9 800| |electrical endurance(operatingcycles)/ at AC-3 / at 380/415 V|5 000| |product feature / for neutral conductors / upgradable/retrofittable|No| |/ short-circuit and overloadproof|| |ground-fault monitoringversion|Without| |product function|| |● communication function|Yes| |●phase failure detection|Yes| |● other measurement function|No| |Net Weight|2.13 kg| |**Current**|| |operational current|| |● at 40 °C|100 A| |● at 45 °C|100 A| |● at 50 °C|100 A| |● at 55 °C|100 A| |● at 60 °C|100 A| |● at 65 °C|100 A| |● at 70 °C|100 A| Subject to change without notice © Copyright Siemens 3VA21105MP320AA0 Page 1/4 5/31/2026 |**Switching capacity according to IEC 60947**|**Switching capacity according to IEC 60947**| |---|---| |switchingcapacityclass of the circuit breaker|E| |maximum short-circuit current breakingcapacity (Icu)|| |● at 240 V|85 kA| |● at 415 V|55 kA| |● at 440 V|55 kA| |● at 500 V|36 kA| |● at 690 V|3 kA| |operatingshort-circuit current breakingcapacity (Ics)|| |● at 240 V|85 kA| |● at 415 V|55 kA| |● at 440 V|55 kA| |● at 500 V|36 kA| |● at 690 V|2.5 kA| |short-circuit current makingcapacity (Icm)|| |● at 240 V|187 kA| |● at 415 V|121 kA| |● at 440 V|121 kA| |● at 500 V|75.5 kA| |● at 690 V|3.7 kA| |**Adjustable parameters**|| |product feature / for L-tripping/ can be switched on/off|No| |adjustable response value setting current (Ir) / of the L-trip / with<br>I2t characteristic|| |● minimum|40 A| |● maximum|100 A| |adjustable response value delay time (tr) / for L-tripping / with I2t<br>characteristic|| |● minimum|3 s| |● maximum|25 s| |adjustable response value setting current (Isd) / of S-trip / with<br>I0t characteristic|| |● minimum|120 A| |● maximum|1 500 A| |adjustable response value delay time (tsd) / for S-tripping / with<br>I0t characteristic|| |● minimum|0.03 s| |● maximum|0.03 s| |adjustable response value settingcurrent(Ii)/ for I-tripping|| |● minimum|300 A| |● maximum|1 500 A| |adjustable settingcurrent(InN)/ for N-tripping|| |● minimum|0 A| |● maximum|0 A| |product function /grounding protection|No| |adjustable tripclass(Tc CLASS)|10A, 10/10E, 20/ 20E, 30/30E| |trippingtime(Tp)/ with adjustable tripclass(Tc CLASS)|| |● minimum|3 s| |● maximum|25 s| |**Mechanical Design**|| |product component|| |● undervoltage release|No| |● voltage trigger|No| |● tripindicator|No| |height[in]|7.13 in| |height|181 mm| |width[in]|4.13 in| |width|105 mm| |depth[in]|3.39 in| |depth|86 mm| Subject to change without notice © Copyright Siemens 3VA21105MP320AA0 Page 2/4 5/31/2026 |**Connections**<br>~~a~~|**Connections**<br>~~a~~|**Connections**<br>~~a~~|**Connections**<br>~~a~~|**Connections**<br>~~a~~|**Connections**<br>~~a~~| |---|---|---|---|---|---| |arrangement of electrical connectors / for main current circuit|Front terminal||||| |type of electrical connection / for main current circuit|on both sides nut keeper kit||||| |type of connectable conductor cross-sections / for flat-bar|13 x 1 mm||||| |terminal connection / minimum|||||| |type of connectable conductor cross-sections / for flat-bar|25 x 8 mm||||| |terminal connection / maximum|||||| |design of the surface / of the connections / on the top of the|tin||||| |switch(N, 1, 3, 5)|||||| |design of the surface / of the connections / on the bottom of the|tin||||| |switch(N, 2, 4, 6)|||||| |**Auxiliary circuit**<br>~~a~~|||||| |number of CO contacts / for auxiliarycontacts|0||||| |**Accessories**<br>~~a~~|||||| |product extension / optional / motor drive|Yes||||| |**Environmental conditions**<br>~~ee~~|||||| |protection class IP / on the front|IP40||||| |ambient temperature|||||| |● duringoperation / minimum|-25 °C||||| |● duringoperation / maximum|70 °C||||| |● duringstorage / minimum|-40 °C||||| |● duringstorage / maximum|80 °C||||| |**Environmental footprint**<br>~~ee~~|||||| |global warming potential[CO2 eq]/ total|61.814 k||61.814 kg||| |global warming potential[CO2 eq]/ duringmanufacturing|14.6 kg||||| |global warming potential[CO2 eq]/ duringoperation|48.9 kg||||| |global warming potential[CO2 eq]/ after end of life|-2.2 kg||||| |Siemens Eco Profile(SEP)<br>Siemens EcoTech<br>~~re~~|||||| |**reference code / according to IEC 81346-2**|Q||||| |**Approvals / Certificates**|||||| |**General Product Approval**|||||| |Miscellaneous<br>~~~~~~|||FAL||Confirmation<br>~~_~~| |**General Product Approval**<br>**EMV**|||**Test Certificates**||| |UK<br>ca<br>Sf<br>@|||Miscellaneous<br>~~—_~~|Special Test Certific-<br>ate|Type Test Certific-<br>ates/Test Report| |**Maritime application**|||**other**||| |CCS (China Classifica-|||Miscellaneous|Miscellaneous|Confirmation| |tion Society)|||||| |renitas!|||||| |**other**<br>**Dangerous goods**<br>**Environment**|||||| |Transport Information<br>Environmental Con-<br>firmations<br>~~— ~~|||Environmental Con-<br>firmations<br> =~~"—~~||| ~~ee~~ **Further information** **Information on the packaging** Subject to change without notice © Copyright Siemens 3VA21105MP320AA0 Page 3/4 5/31/2026 https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/lowvoltage/catalogs **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3VA2110-5MP32-0AA0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3VA2110-5MP32-0AA0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)** https://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VA2110-5MP32-0AA0 **CAx-Online-Generator** https://www.siemens.com/cax **Tender specifications** https://www.siemens.com/specifications **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **last modified:** 4/23/2026 Subject to change without notice © Copyright Siemens 3VA21105MP320AA0 Page 4/4 5/31/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →