- Manufacturer: SIEMENS
- Product type: Electronic Circuit Breakers
- SVHC: To Be Advised
- Trip Time: -
- No. of Poles: 3 Pole
- Product Range: SENTRON 3VA2 Series
- Current Rating: 100A
- Supply Voltage: 690V
- Load Current Max: -
- Circuit Breaker Mounting: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 667.59 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3VA2110-5HN36-0AF0** **Data sheet** circuit breaker 3VA2 IEC Frame 160 breaking capacity class M Icu=55 kA @ 415 V 3-pole, line protection ETU350, LSI, In=100 A overload protection Ir=40 A...100 A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In terminal connection 1 auxiliary switch HQ 1 trip alarm switch HQ |3<br>,|circuit breaker 3VA2 IEC Frame 160 breaking capacity class M Icu=55 kA @ 415 V<br>3-pole, line protection ETU350, LSI, In=100 A overload protection Ir=40 A...100 A<br>short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In terminal connection 1 auxiliary<br>switch HQ 1 trip alarm switch HQ<br>3<br>,| |---|---| |**Model**|| |product brand name|SENTRON| |product designation|Molded case circuit breaker| |design of theproduct|Lineprotection| |design of the overcurrent release|ETU350| |protection function of the overcurrent release|LSI| |number ofpoles|3| |design of the auxiliaryswitch|1 auxiliaryswitch + 1 trip alarm switch HQ| |**General technical data**<br>~~|~~|| |insulation voltage / rated value<br>~~|~~|800 V<br>~~|~~| |operatingvoltage / at AC / rated value|690 V| |power loss[W]/ maximum|10 W| |power loss [W] / for rated value of the current / at AC / in hot<br>operatingstate /perpole|3.33 W| |mechanical service life(operatingcycles)/ typical|25 000| |electrical endurance(operatingcycles)/ at AC-1 / at 380/415 V|14 000| |electrical endurance(operatingcycles)/ at AC-1 / at 690 V|9 800| |product feature / for neutral conductors / upgradable/retrofittable<br>/ short-circuit and overloadproof|No| |ground-fault monitoringversion|Without| |product function|| |● communication function|No| |● other measurement function|No| |Net Weight|2.49 kg| |**Current**<br>~~|~~|| |operational current<br>~~|~~|~~|~~| |● at 40 °C|100 A| |● at 45 °C|100 A| |● at 50 °C|100 A| |● at 55 °C|100 A| |● at 60 °C|100 A| |● at 65 °C|100 A| |● at 70 °C|100 A| |**Switching capacity according to IEC 60947**<br>~~|~~|| |switchingcapacityclass of the circuit breaker<br>~~|~~|M<br>~~|~~| |maximum short-circuit current breakingcapacity (Icu)|| |● at 240 V|85 kA| |● at 415 V|55 kA| |● at 440 V|55 kA| Subject to change without notice © Copyright Siemens 3VA21105HN360AF0 Page 1/6 6/4/2026 ||● at 500 V|36 kA|| |---|---|---|---| ||● at 690 V|3 kA|| ||operatingshort-circuit current breakingcapacity (Ics)||| ||● at 240 V|85 kA|| ||● at 415 V|55 kA|| ||● at 440 V|55 kA|| ||● at 500 V|36 kA|| ||● at 690 V|2.5 kA|| ||short-circuit current makingcapacity (Icm)||| ||● at 240 V|187 kA|| ||● at 415 V|121 kA|| ||● at 440 V|121 kA|| ||● at 500 V|75.5 kA|| ||● at 690 V|3.7 kA|| ||**Adjustable parameters**||| ||product feature / for L-tripping/ can be switched on/off|No|| ||adjustable response value setting current (Ir) / of the L-trip / with<br>I2t characteristic||| ||● minimum|40 A|| ||● maximum|100 A|| ||adjustable response value delay time (tr) / for L-tripping / with I2t<br>characteristic||| ||● minimum|0.5 s|| ||● maximum|17 s|| ||adjustable response value setting current (Isd) / of S-trip / with<br>I2t characteristic||| ||● minimum|60 A|| ||● maximum|1 000 A|| ||adjustable response value delay time (tsd) / for S-tripping / with<br>I2t characteristic||| ||● minimum|0.0001 s|| ||● maximum|0.4 s|| ||adjustable response value settingcurrent(Ii)/ for I-tripping||| ||● minimum|1 200 A|| ||● maximum|1 200 A|| ||product function /groundingprotection|No|| ||**Mechanical Design**||| ||product component||| ||● undervoltage release|No|| ||● voltage trigger|No|| ||● tripindicator|Yes|| ||height[in]|7.13 in|| ||height|181 mm|| ||width[in]|4.13 in|| ||type of connectable conductor cross-sections / of the round<br>conductor terminal / stranded|1 x (6 - 120 mm²)|| ||width|105 mm|| ||depth[in]|3.39 in|| ||depth|86 mm|| ||**Connections**||| ||arrangement of electrical connectors / for main current circuit|Front terminal|| ||type of electrical connection / for main current circuit|double-sided box terminal|| ||design of the surface / of the connections / on the top of the<br>switch(N, 1, 3, 5)|tin|| ||design of the surface / of the connections / on the bottom of the<br>switch(N, 2, 4, 6)|tin|| ||**Auxiliary circuit**||| ||number of CO contacts / for auxiliarycontacts|2|| ||**Accessories**||| ||product extension / optional / motor drive|Yes|| ||manufacturer's article number||| Subject to change without notice © Copyright Siemens 3VA21105HN360AF0 Page 2/6 6/4/2026 |● of the supplied basic switch|3VA21105HN360AA0| |---|---| |● of the integrated auxiliaryswitch/alarm switch<br>~~NE~~|3VA9988-0AA12| |● of the integrated auxiliaryswitch/alarm switch<br>~~NE~~|3VA9988-0AB12| |**Environmental conditions**<br>~~NE~~|| |protection class IP / on the front<br>~~NE~~|IP40| |ambient temperature|| |● duringoperation / minimum|-25 °C| |● duringoperation / maximum|70 °C| |● duringstorage / minimum|-40 °C| |● duringstorage / maximum|80 °C| |**reference code / according to IEC 81346-2**|Q| |**Approvals / Certificates**<br>~~a~~|| |**General Product Approval**<br>~~a~~|| ~~at)~~ Miscellaneous Confirmation **General Product Approval EMV Test Certificates** Miscellaneous Special Test CertificType Test CertificcAca Sf£§ @ ~~TO~~ ate ates/Test Report **Maritime application** - CCS (China Classifica tion Society) **other Dangerous goods Environment** Miscellaneous Miscellaneous Confirmation Transport Information Environmental Confirmations QC PASS ~~i — a~~ ae) **Environment** Environmental Confirmations ~~e~~ **Further information** ~~s~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/lowvoltage/catalogs **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3VA2110-5HN36-0AF0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3VA2110-5HN36-0AF0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)** https://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VA2110-5HN36-0AF0 **CAx-Online-Generator** https://www.siemens.com/cax Subject to change without notice © Copyright Siemens 3VA21105HN360AF0 Page 3/6 6/4/2026 **Tender specifications** https://www.siemens.com/specifications **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **==> picture [203 x 225] intentionally omitted <==** **==> picture [343 x 294] intentionally omitted <==** **----- Start of picture text -----**<br> -Q<br>L<br>I > S<br>I >> I<br>**----- End of picture text -----**<br> L (Long Time Delay / Überlastschutz); S (Short Time Delay / Kurzschlussschutz, kurzzeitverzögert); I (Instantaneous / Kurzschlussschutz, unverzögert); Subject to change without notice © Copyright Siemens 3VA21105HN360AF0 Page 4/6 6/4/2026 **last modified:** 4/23/2026 Subject to change without notice © Copyright Siemens 3VA21105HN360AF0 Page 5/6 6/4/2026 Subject to change without notice © Copyright Siemens 3VA21105HN360AF0 Page 6/6 6/4/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →