- Manufacturer: SIEMENS
- Product type: Electronic Circuit Breakers
- SVHC: To Be Advised
- Trip Time: -
- No. of Poles: 3 Pole
- Product Range: SENTRON 3VA2 Series
- Current Rating: 63A
- Supply Voltage: 690V
- Load Current Max: -
- Circuit Breaker Mounting: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1061.4 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Data sheet**
**3VA2063-7HM32-0AA0**
circuit breaker 3VA2 IEC Frame 100 breaking capacity class C Icu=110 kA @ 415 V 3-pole, line protection ETU330, LIG, In=63 A overload protection Ir=25 A...63 A short-circuit protection Ii=1.5...12 x In ground-fault protection Ig=0.25... 1 x In, tg=0.1/0.3s nut keeper kit
|**Model**||
|---|---|
|product brand name|SENTRON|
|product designation|Molded case circuit breaker|
|design of theproduct|Lineprotection|
|design of the overcurrent release|ETU330|
|protection function of the overcurrent release|LIG|
|number of poles|3|
|**General technical data**||
|insulation voltage / rated value|800 V|
|operatingvoltage / at AC / rated value|690 V|
|power loss[W]/ maximum|3 W|
|power loss [W] / for rated value of the current / at AC / in hot|1 W|
|operatingstate /perpole||
|mechanical service life(operatingcycles)/ typical|25 000|
|electrical endurance(operatingcycles)/ at AC-1 / at 380/415 V|15 000|
|electrical endurance(operatingcycles)/ at AC-1 / at 690 V|10 500|
|product feature / for neutral conductors / upgradable/retrofittable|No|
|/ short-circuit and overloadproof||
|ground-fault monitoringversion|Summation current formation L-conductor|
|product function||
|● communication function|No|
|● other measurement function|No|
|Net Weight|2.5 kg|
|**Current**||
|operational current||
|● at 40 °C|63 A|
|● at 45 °C|63 A|
|● at 50 °C|63 A|
|● at 55 °C|63 A|
|● at 60 °C|63 A|
|● at 65 °C|63 A|
|● at 70 °C|63 A|
|**Switching capacity according to IEC 60947**||
|switchingcapacityclass of the circuit breaker|C|
|maximum short-circuit current breakingcapacity (Icu)||
|● at 240 V|150 kA|
Subject to change without notice © Copyright Siemens
3VA20637HM320AA0 Page 1/4
5/30/2026
|● at 415 V|110 kA|
|---|---|
|● at 440 V|110 kA|
|● at 500 V|85 kA|
|● at 690 V|2 kA|
|operatingshort-circuit current breakingcapacity (Ics)||
|● at 240 V|150 kA|
|● at 415 V|110 kA|
|● at 440 V|110 kA|
|● at 500 V|85 kA|
|● at 690 V|2 kA|
|short-circuit current makingcapacity (Icm)||
|● at 240 V|330 kA|
|● at 415 V|242 kA|
|● at 440 V|242 kA|
|● at 500 V|187 kA|
|● at 690 V|3 kA|
|**Adjustable parameters**||
|product feature / for L-tripping/ can be switched on/off|No|
|adjustable response value setting current (Ir) / of the L-trip / with<br>I2t characteristic||
|● minimum|25 A|
|● maximum|63 A|
|adjustable response value delay time (tr) / for L-tripping / with I2t<br>characteristic||
|● minimum|0.5 s|
|● maximum|17 s|
|adjustable response value settingcurrent(Ii)/ for I-tripping||
|● minimum|94 A|
|● maximum|756 A|
|adjustable current response value current / for G-tripping / with<br>standard characteristic||
|● initial value|15 A|
|● full-scale value|63 A|
|adjustable response value delay time (tg) / for G-tripping / with<br>I0t characteristic||
|● minimum|0.1 s|
|● maximum|0.3 s|
|adjustable settingcurrent(InN)/ for N-tripping||
|● minimum|0 A|
|● maximum|0 A|
|product function /groundingprotection|Yes|
|**Mechanical Design**||
|product component||
|● undervoltage release|No|
|● voltage trigger|No|
|● tripindicator|No|
|height[in]|7.13 in|
|height|181 mm|
|width[in]|4.13 in|
|width|105 mm|
|depth[in]|3.39 in|
|depth|86 mm|
|**Connections**||
|arrangement of electrical connectors / for main current circuit|Front terminal|
|type of electrical connection / for main current circuit|on both sides nut keeper kit|
|type of connectable conductor cross-sections / for flat-bar<br>terminal connection / minimum|13 x 1 mm|
|type of connectable conductor cross-sections / for flat-bar<br>terminal connection / maximum|25 x 8 mm|
|design of the surface / of the connections / on the top of the<br>switch (N, 1, 3, 5)|tin|
Subject to change without notice © Copyright Siemens
3VA20637HM320AA0 Page 2/4
5/30/2026
|design of the surface / of the connections / on the bottom of the|design of the surface / of the connections / on the bottom of the|design of the surface / of the connections / on the bottom of the||tin||||||
|---|---|---|---|---|---|---|---|---|---|
|switch(N, 2, 4, 6)||||||||||
|**Auxiliary circuit**<br>~~ee~~||||||||||
|number of CO contacts / for auxiliarycontacts||||0||||||
|**Accessories**<br>~~et~~||||||||||
|product extension / optional / motor drive||||Yes||||||
|**Environmental conditions**<br>protection class IP / on the front<br>~~a~~||||IP40||||||
|ambient temperature||||||||||
|● duringoperation / minimum||||-25 °C||||||
|● duringoperation / maximum||||70 °C||||||
|● duringstorage / minimum||||-40 °C||||||
|● duringstorage / maximum||||80 °C||||||
|**Environmental footprint**<br>global warming potential[CO2 eq]/ total<br>~~a~~||||61.814 k||61.814 kg||||
|global warming potential[CO2 eq]/ duringmanufacturing||||14.6 kg||||||
|global warming potential[CO2 eq]/ duringoperation||||48.9 kg||||||
|global warming potential[CO2 eq]/ after end of life||||-2.2 kg||||||
|Siemens Eco Profile(SEP)<br>~~re~~||||Siemens EcoTech||||||
|**reference code / according to IEC 81346-2**||||Q||||||
|**Approvals / Certificates**||||||||||
|**General Product Approval**||||||||||
|||Miscellaneous<br>~~FA~~L|||||||Confirmation<br>~~_~~|
|**General Product Ap-**<br>**proval**<br>**EMV**||**Test Certificates**|||||||**Maritime application**|
|||Special Test Certific-|||||Miscellaneous|Type Test Certific-||
|||ate||||||ates/Test Report||
|**Maritime application**||||||||**other**||
||||||CCS (China Classifica-|||Miscellaneous|Miscellaneous|
||||||||tion Society)|||
|renitas!||||||||||
|**other**||**Dangerous goods**||||**Environment**||||
|Confirmation<br>~~——~~<br>QC PASS|Transport Information<br>~~——_ ~~|||||Environmental Con-<br>firmations<br> ~~-—=_ ~~||Environmental Con-<br>firmations<br> ~~—~~|ie<br>EPD|
|**Environment**||||||||||
**Further information** ~~ee~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875
Subject to change without notice © Copyright Siemens
3VA20637HM320AA0 Page 3/4
5/30/2026
**Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/lowvoltage/catalogs **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3VA2063-7HM32-0AA0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3VA2063-7HM32-0AA0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)** https://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VA2063-7HM32-0AA0 **CAx-Online-Generator** https://www.siemens.com/cax **Tender specifications** https://www.siemens.com/specifications **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no>
**==> picture [258 x 330] intentionally omitted <==**
**----- Start of picture text -----**<br>
-Q<br>ELr _ _ _ a ETU330<br>! L<br>I>> I<br>r achce<br>G<br>I>> I>> I>><br>I>> I>> I>><br>{ |<br>P|<br>{ | |<br>||<br>{|<br>EFB RCD<br>|<br>1 3 5<br>2 4 6 -X2 -X3<br>**----- End of picture text -----**<br>
**last modified:** 4/3/2025
Subject to change without notice © Copyright Siemens
3VA20637HM320AA0 Page 4/4
5/30/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →