Image not available
Illustrative purposes only
3VA2025-8KP42-0AA0
Electronic Circuit Breaker, MCCB, 3VA2, 4P, 150 kA, 415 V, 25 A, Without Auxiliary Contact
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Electronic Circuit Breakers
- SVHC: To Be Advised
- Trip Time: -
- No. of Poles: 4 Pole
- Product Range: SENTRON 3VA2 Series
- Current Rating: 250A
- Supply Voltage: 690V
- Load Current Max: -
- Circuit Breaker Mounting: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1896.6 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3VA2025-8KP42-0AA0** **Data sheet** circuit breaker 3VA2 IEC Frame 100 breaking capacity class L Icu=150 kA @ 415 V 4-pole, line protection ETU850, LSI, In=25 A overload protection Ir=10 A...25 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In neutral conductor protection adjustable (OFF, up to 160%) nut keeper kit |**Model**|| |---|---| |product brand name|SENTRON| |product designation|Molded case circuit breaker| |design of theproduct|Lineprotection| |design of the overcurrent release|ETU850| |protection function of the overcurrent release|LSI| |number of poles|4| |**General technical data**|| |insulation voltage / rated value|800 V| |operatingvoltage / at AC / rated value|690 V| |power loss[W]/ maximum|0.5 W| |power loss [W] / for rated value of the current / at AC / in hot|0.17 W| |operatingstate /perpole|| |mechanical service life(operatingcycles)/ typical|25 000| |electrical endurance(operatingcycles)/ at AC-1 / at 380/415 V|15 000| |electrical endurance(operatingcycles)/ at AC-1 / at 690 V|10 500| |product feature / for neutral conductors / upgradable/retrofittable|No| |/ short-circuit and overloadproof|| |ground-fault monitoringversion|Without| |product function|| |● communication function|Yes| |● other measurement function|Yes| |Net Weight|3.2 kg| |**Current**|| |operational current|| |● at 40 °C|25 A| |● at 45 °C|25 A| |● at 50 °C|25 A| |● at 55 °C|25 A| |● at 60 °C|25 A| |● at 65 °C|25 A| |● at 70 °C|25 A| |**Switching capacity according to IEC 60947**|| |switchingcapacityclass of the circuit breaker|L| |maximum short-circuit current breakingcapacity (Icu)|| |● at 240 V|200 kA| Subject to change without notice © Copyright Siemens 3VA20258KP420AA0 Page 1/4 5/31/2026 ||● at 415 V|150 kA|| |---|---|---|---| ||● at 440 V|150 kA|| ||● at 500 V|100 kA|| ||● at 690 V|25 kA|| ||operatingshort-circuit current breakingcapacity (Ics)||| ||● at 240 V|200 kA|| ||● at 415 V|150 kA|| ||● at 440 V|150 kA|| ||● at 500 V|100 kA|| ||● at 690 V|18 kA|| ||short-circuit current makingcapacity (Icm)||| ||● at 240 V|440 kA|| ||● at 415 V|330 kA|| ||● at 440 V|330 kA|| ||● at 500 V|220 kA|| ||● at 690 V|52.5 kA|| ||**Adjustable parameters**||| ||product feature / for L-tripping/ can be switched on/off|No|| ||adjustable response value setting current (Ir) / of the L-trip / with<br>I2t characteristic||| ||● minimum|10 A|| ||● maximum|25 A|| ||adjustable response value delay time (tr) / for L-tripping / with I2t<br>characteristic||| ||● minimum|0.5 s|| ||● maximum|25 s|| ||adjustable response value setting current (Isd) / of S-trip / with<br>I0t characteristic||| ||● minimum|15 A|| ||● maximum|250 A|| ||adjustable response value setting current (Isd) / of S-trip / with<br>I2t characteristic||| ||● minimum|15 A|| ||● maximum|250 A|| ||adjustable response value delay time (tsd) / for S-tripping / with<br>I0t characteristic||| ||● minimum|0.05 s|| ||● maximum|0.5 s|| ||adjustable response value delay time (tsd) / for S-tripping / with<br>I2t characteristic||| ||● minimum|0.05 s|| ||● maximum|0.5 s|| ||adjustable response value settingcurrent(Ii)/ for I-tripping||| ||● minimum|37 A|| ||● maximum|300 A|| ||adjustable settingcurrent(InN)/ for N-tripping||| ||● minimum|10 A|| ||● maximum|40 A|| ||design of the N-conductorprotection|adjustable OFF; 40% to 160%|| ||product function /groundingprotection|No|| ||**Mechanical Design**||| ||product component||| ||● undervoltage release|No|| ||● voltage trigger|No|| ||● tripindicator|No|| ||height[in]|7.13 in|| ||height|181 mm|| ||width[in]|5.51 in|| ||width|140 mm|| ||depth[in]|3.39 in|| ||depth|86 mm|| Subject to change without notice © Copyright Siemens 3VA20258KP420AA0 Page 2/4 5/31/2026 **==> picture [511 x 677] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||| |---|---|---|---|---|---| |a|Connections| |arrangement of electrical connectors / for main current circuit|Front terminal| |type of electrical connection / for main current circuit|on both sides nut keeper kit| |type of connectable conductor cross-sections / for flat-bar|13 x 1 mm| |terminal connection / minimum| |type of connectable conductor cross-sections / for flat-bar|25 x 8 mm| |terminal connection / maximum| |design of the surface / of the connections / on the top of the|tin| |switch (N, 1, 3, 5)| |design of the surface / of the connections / on the bottom of the|tin| |switch (N, 2, 4, 6)| |a|Auxiliary circuit| |number of CO contacts / for auxiliary contacts|0| |a|Accessories| |product extension / optional / motor drive|Yes| |Environmental conditions| |ee| |protection class IP / on the front|IP40| |ambient temperature| |● during operation / minimum|-25 °C| |● during operation / maximum|70 °C| |● during storage / minimum|-40 °C| |● during storage / maximum|80 °C| |ee|Environmental footprint| |global warming|potential [CO2 eq] / total|61.814 kg| |global warming|potential [CO2 eq] / during manufacturing|14.6 kg| |global warming|potential [CO2 eq] / during operation|48.9 kg| |global warming|potential [CO2 eq] / after end of life|-2.2 kg| |re|Siemens Eco Profile (SEP)|Siemens EcoTech| |reference code / according to IEC 81346-2|Q| |Approvals / Certificates| |General Product Approval| |~~|Miscellaneous|FAL|_|Confirmation| |General Product Approval|EMV|Test Certificates| |Miscellaneous|Special Test Certific-|Type Test Certific-| |ate|ates/Test Report| |UKca|Sf|@|——_—_—| |Maritime application| |-| |CCS (China Classifica| |tion Society)| |7|a|us|=|os|os| |other|Dangerous goods|Environment| |ss|Miscellaneous|Miscellaneous|Confirmation|Transport Information|Environmental Con-| |firmations| **----- End of picture text -----**<br> **Environment** Subject to change without notice © Copyright Siemens 3VA20258KP420AA0 Page 3/4 5/31/2026 firmations ~~—__~~ Environmental Confirmations ~~e~~ **Further information** ~~e~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/lowvoltage/catalogs **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3VA2025-8KP42-0AA0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3VA2025-8KP42-0AA0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)** https://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VA2025-8KP42-0AA0 **CAx-Online-Generator** https://www.siemens.com/cax **Tender specifications** https://www.siemens.com/specifications **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> ~~re~~ **last modified:** 4/3/2025 Subject to change without notice © Copyright Siemens 3VA20258KP420AA0 Page 4/4 5/31/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →