Image not available
Illustrative purposes only
3VA2025-5HM36-0AA0
Electronic Circuit Breaker, MCCB, 3VA2, 3P, 55 kA, 415 V, 25 A, Without Auxiliary Contact
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Electronic Circuit Breakers
- SVHC: To Be Advised
- Trip Time: -
- No. of Poles: 3 Pole
- Product Range: SENTRON 3VA2 Series
- Current Rating: 250A
- Supply Voltage: 690V
- Load Current Max: -
- Circuit Breaker Mounting: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 882.0 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3VA2025-5HM36-0AA0** **Data sheet** circuit breaker 3VA2 IEC Frame 100 breaking capacity class M Icu=55 kA @ 415 V 3-pole, line protection ETU330, LIG, In=25 A overload protection Ir=10 A...25 A short-circuit protection Ii=1.5...12 x In ground-fault protection Ig=0.6... 1 x In, tg=0.1/0.3s terminal connection |**Model**|| |---|---| |product brand name|SENTRON| |product designation|Molded case circuit breaker| |design of theproduct|Lineprotection| |design of the overcurrent release|ETU330| |protection function of the overcurrent release|LIG| |number of poles|3| |**General technical data**|| |insulation voltage / rated value|800 V| |operatingvoltage / at AC / rated value|690 V| |power loss[W]/ maximum|0.84 W| |power loss [W] / for rated value of the current / at AC / in hot|0.28 W| |operatingstate /perpole|| |mechanical service life(operatingcycles)/ typical|25 000| |electrical endurance(operatingcycles)/ at AC-1 / at 380/415 V|15 000| |electrical endurance(operatingcycles)/ at AC-1 / at 690 V|10 500| |product feature / for neutral conductors / upgradable/retrofittable|No| |/ short-circuit and overloadproof|| |ground-fault monitoringversion|Summation current formation L-conductor| |product function|| |● communication function|No| |● other measurement function|No| |Net Weight|2.5 kg| |**Current**|| |operational current|| |● at 40 °C|25 A| |● at 45 °C|25 A| |● at 50 °C|25 A| |● at 55 °C|25 A| |● at 60 °C|25 A| |● at 65 °C|25 A| |● at 70 °C|25 A| |**Switching capacity according to IEC 60947**|| |switchingcapacityclass of the circuit breaker|M| |maximum short-circuit current breakingcapacity (Icu)|| |● at 240 V|85 kA| Subject to change without notice © Copyright Siemens 3VA20255HM360AA0 Page 1/6 5/31/2026 |● at 415 V|55 kA| |---|---| |● at 440 V|55 kA| |● at 500 V|36 kA| |● at 690 V|2 kA| |operatingshort-circuit current breakingcapacity (Ics)|| |● at 240 V|85 kA| |● at 415 V|55 kA| |● at 440 V|55 kA| |● at 500 V|36 kA| |● at 690 V|2 kA| |short-circuit current makingcapacity (Icm)|| |● at 240 V|187 kA| |● at 415 V|121 kA| |● at 440 V|121 kA| |● at 500 V|75.5 kA| |● at 690 V|3 kA| |**Adjustable parameters**|| |product feature / for L-tripping/ can be switched on/off|No| |adjustable response value setting current (Ir) / of the L-trip / with<br>I2t characteristic|| |● minimum|10 A| |● maximum|25 A| |adjustable response value delay time (tr) / for L-tripping / with I2t<br>characteristic|| |● minimum|0.5 s| |● maximum|17 s| |adjustable response value settingcurrent(Ii)/ for I-tripping|| |● minimum|37 A| |● maximum|300 A| |adjustable current response value current / for G-tripping / with<br>standard characteristic|| |● initial value|15 A| |● full-scale value|25 A| |adjustable response value delay time (tg) / for G-tripping / with<br>I0t characteristic|| |● minimum|0.1 s| |● maximum|0.3 s| |adjustable settingcurrent(InN)/ for N-tripping|| |● minimum|0 A| |● maximum|0 A| |product function /groundingprotection|Yes| |**Mechanical Design**|| |product component|| |● undervoltage release|No| |● voltage trigger|No| |● tripindicator|No| |height[in]|7.13 in| |height|181 mm| |width[in]|4.13 in| |type of connectable conductor cross-sections / of the round<br>conductor terminal / stranded|1 x (6 - 120 mm²)| |width|105 mm| |depth[in]|3.39 in| |depth|86 mm| |**Connections**|| |arrangement of electrical connectors / for main current circuit|Front terminal| |type of electrical connection / for main current circuit|double-sided box terminal| |design of the surface / of the connections / on the top of the<br>switch(N, 1, 3, 5)|tin| |design of the surface / of the connections / on the bottom of the<br>switch (N, 2, 4, 6)|tin| Subject to change without notice © Copyright Siemens 3VA20255HM360AA0 Page 2/6 5/31/2026 |**Auxiliary circuit**<br>~~a~~|**Auxiliary circuit**<br>~~a~~|**Auxiliary circuit**<br>~~a~~|**Auxiliary circuit**<br>~~a~~|**Auxiliary circuit**<br>~~a~~|**Auxiliary circuit**<br>~~a~~|**Auxiliary circuit**<br>~~a~~| |---|---|---|---|---|---|---| |number of CO contacts / for auxiliarycontacts||0||||| |**Accessories**<br>~~a~~||||||| |product extension / optional / motor drive||Yes||||| |**Environmental conditions**<br>~~ee~~||||||| |protection class IP / on the front||IP40||||| |ambient temperature||||||| |● duringoperation / minimum||-25 °C||||| |● duringoperation / maximum||70 °C||||| |● duringstorage / minimum||-40 °C||||| |● duringstorage / maximum||80 °C||||| |**Environmental footprint**<br>~~ee~~||||||| |global warming potential[CO2 eq]/ total||61.814 k||61.814 kg||| |global warming potential[CO2 eq]/ duringmanufacturing||14.6 kg||||| |global warming potential[CO2 eq]/ duringoperation||48.9 kg||||| |global warming potential[CO2 eq]/ after end of life||-2.2 kg||||| |Siemens Eco Profile(SEP)<br>Siemens EcoTech<br>~~re~~||||||| |**reference code / according to IEC 81346-2**||Q||||| |**Approvals / Certificates**||||||| |**General Product Approval**||||||| ||Miscellaneous<br>~~~~~~|||FAL||Confirmation<br>~~_~~| |**General Product Approval**|**EMV**|||**Test Certificates**||| |UK<br>ca<br>Sf|@|||Miscellaneous<br>~~—_~~|Special Test Certific-<br>ate|Type Test Certific-<br>ates/Test Report| |**Maritime application**||||||**other**| ||||||CCS (China Classifica-|Miscellaneous| ||||||tion Society)|| |renitas!||||||| |**other**||||**Dangerous goods**|**Environment**|| |Miscellaneous<br>Confirmation||||Transport Information|Environmental Con-|| ||||||firmations|| |**Environment**||||||| |Environmental Con-||||||| |firmations<br>~~—-~~_<br>EPD||||||| |**Further information**<br>~~ee~~||||||| |**Information on the packaging**||||||| |https://support.industry.siemens.com/cs/ww/en/view/109813875||||||| |**Information for data generation and storage**||||||| |https://support.industry.siemens.com/cs/ww/en/view/109995012||||||| |**Information- and Downloadcenter (Catalogs, Brochures,…)**||||||| Subject to change without notice © Copyright Siemens 3VA20255HM360AA0 Page 3/6 5/31/2026 https://www.siemens.com/lowvoltage/catalogs **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3VA2025-5HM36-0AA0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3VA2025-5HM36-0AA0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)** https://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VA2025-5HM36-0AA0 **CAx-Online-Generator** https://www.siemens.com/cax **Tender specifications** https://www.siemens.com/specifications **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **==> picture [203 x 225] intentionally omitted <==** Subject to change without notice © Copyright Siemens 3VA20255HM360AA0 Page 4/6 5/31/2026 **==> picture [367 x 378] intentionally omitted <==** **----- Start of picture text -----**<br> -Q<br>ELr _ _ _ a ETU330<br>! L<br>I>> I<br>ee<br>G<br>I>> I>> I>><br>P EE<br>:<br>I>> I>> I>><br>| |<br>Hy |<br>| |<br>7 ||<br>|<br>1 |<br>EFB RCD<br>|<br>l is e 7<br>last modified: 4/23/2026 (Sa<br>1 3 5<br>2 4 6 -X2 -X3<br>**----- End of picture text -----**<br> Subject to change without notice © Copyright Siemens 3VA20255HM360AA0 Page 5/6 5/31/2026 Subject to change without notice © Copyright Siemens 3VA20255HM360AA0 Page 6/6 5/31/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →