3VA2010-7KQ36-0AA0
Electronic Circuit Breaker, MCCB, 3VA2, 3P, 110 kA, 415 V, 100 A, Without Auxiliary Contact
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Electronic Circuit Breakers
- SVHC: To Be Advised
- Trip Time: -
- No. of Poles: 3 Pole
- Product Range: SENTRON 3VA2 Series
- Current Rating: 100A
- Supply Voltage: 690V
- Load Current Max: -
- Circuit Breaker Mounting: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1896.6 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3VA2010-7KQ36-0AA0** **Data sheet** circuit breaker 3VA2 IEC Frame 100 breaking capacity class C Icu=110 kA @ 415 V 3-pole, line protection ETU860, LSIG, In=100 A overload protection Ir=40 A...100 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In neutral conductor protection optionally with external current transformer, up to 160% ground-fault protection, can be switched off Ig=0.2...1 x In, tg=0.05-0.8s terminal connection |**Model**|| |---|---| |product brand name|SENTRON| |product designation|Molded case circuit breaker| |design of theproduct|Lineprotection| |design of the overcurrent release|ETU860| |protection function of the overcurrent release|LSIG| |number of poles|3| |**General technical data**|| |insulation voltage / rated value|800 V| |operatingvoltage / at AC / rated value|690 V| |power loss[W]/ maximum|7.7 W| |power loss [W] / for rated value of the current / at AC / in hot|2.57 W| |operatingstate /perpole|| |mechanical service life(operatingcycles)/ typical|25 000| |electrical endurance(operatingcycles)/ at AC-1 / at 380/415 V|15 000| |electrical endurance(operatingcycles)/ at AC-1 / at 690 V|10 500| |product feature / for neutral conductors / upgradable/retrofittable|Yes| |/ short-circuit and overloadproof|| |ground-fault monitoringversion|Summation current formation L-conductor| |product function|| |● communication function|Yes| |● other measurement function|Yes| |Net Weight|2.5 kg| |**Current**|| |operational current|| |● at 40 °C|100 A| |● at 45 °C|100 A| |● at 50 °C|100 A| |● at 55 °C|100 A| |● at 60 °C|100 A| |● at 65 °C|100 A| |● at 70 °C|100 A| |**Switching capacity according to IEC 60947**|| |switchingcapacityclass of the circuit breaker|C| |maximum short-circuit current breakingcapacity (Icu)|| |● at 240 V|150 kA| 3VA20107KQ360AA0 Page 1/7 Subject to change without notice © Copyright Siemens 5/30/2026 |● at 415 V|110 kA| |---|---| |● at 440 V|110 kA| |● at 500 V|85 kA| |● at 690 V|2 kA| |operatingshort-circuit current breakingcapacity (Ics)|| |● at 240 V|150 kA| |● at 415 V|110 kA| |● at 440 V|110 kA| |● at 500 V|85 kA| |● at 690 V|2 kA| |short-circuit current makingcapacity (Icm)|| |● at 240 V|330 kA| |● at 415 V|242 kA| |● at 440 V|242 kA| |● at 500 V|187 kA| |● at 690 V|3 kA| |**Adjustable parameters**|| |product feature / for L-tripping/ can be switched on/off|No| |adjustable response value setting current (Ir) / of the L-trip / with<br>I2t characteristic|| |● minimum|40 A| |● maximum|100 A| |adjustable response value delay time (tr) / for L-tripping / with I2t<br>characteristic|| |● minimum|0.5 s| |● maximum|25 s| |adjustable response value setting current (Isd) / of S-trip / with<br>I0t characteristic|| |● minimum|60 A| |● maximum|1 000 A| |adjustable response value setting current (Isd) / of S-trip / with<br>I2t characteristic|| |● minimum|60 A| |● maximum|1 000 A| |adjustable response value delay time (tsd) / for S-tripping / with<br>I0t characteristic|| |● minimum|0.05 s| |● maximum|0.5 s| |adjustable response value delay time (tsd) / for S-tripping / with<br>I2t characteristic|| |● minimum|0.05 s| |● maximum|0.5 s| |adjustable response value settingcurrent(Ii)/ for I-tripping|| |● minimum|150 A| |● maximum|1 200 A| |adjustable current response value current / for G-tripping / with<br>standard characteristic|| |● initial value|20 A| |● full-scale value|100 A| |adjustable response value delay time (tg) / for G-tripping / with<br>I0t characteristic|| |● minimum|0.05 s| |● maximum|0.8 s| |adjustable response value setting current (Ig) / for G-tripping /<br>with I2t characteristic|| |● minimum|20 A| |● maximum|100 A| |adjustable response value delay time (tg) / for G-tripping / with<br>I2t characteristic|| |● minimum|0.05 s| |● maximum|0.8 s| |adjustable setting current (InN) / for N-tripping|| 3VA20107KQ360AA0 Page 2/7 Subject to change without notice © Copyright Siemens 5/30/2026 |● minimum|20 A| |---|---| |● maximum|160 A| |design of the N-conductorprotection<br>~~re~~|adjustable OFF; 20% to 160%<br>~~re~~| |product function /groundingprotection<br>~~re~~|Yes<br>~~re~~| |**Mechanical Design**|| |product component|| |● undervoltage release|No| |● voltage trigger|No| |● tripindicator|No| |height[in]|7.13 in| |height|181 mm| |width[in]|4.13 in| |type of connectable conductor cross-sections / of the round<br>conductor terminal / stranded|1 x (6 - 120 mm²)| |width<br>~~re~~|105 mm<br>~~re~~| |depth[in]<br>~~re~~|3.39 in<br>~~re~~| |depth<br>~~re~~|86 mm<br>~~re~~| |**Connections**|| |arrangement of electrical connectors / for main current circuit|Front terminal| |type of electrical connection / for main current circuit|double-sided box terminal| |design of the surface / of the connections / on the top of the<br>switch(N, 1, 3, 5)|tin| |design of the surface / of the connections / on the bottom of the<br>switch(N, 2, 4, 6)|tin| |**Auxiliary circuit**<br>~~a~~|| |number of CO contacts / for auxiliarycontacts<br>~~a~~|0<br>~~a~~| |**Accessories**<br>~~a~~|| |product extension / optional / motor drive<br>~~a~~|Yes<br>~~a~~| |**Environmental conditions**<br>~~a~~|| |protection class IP / on the front<br>~~a~~|IP40<br>~~a~~| |ambient temperature|| |● duringoperation / minimum|-25 °C| |● duringoperation / maximum|70 °C| |● duringstorage / minimum|-40 °C| |● duringstorage / maximum|80 °C| |**Environmental footprint**<br>~~a~~|| |global warming potential[CO2 eq]/ total<br>~~a~~|61.814 kg<br>~~a~~| |global warming potential[CO2 eq]/ duringmanufacturing|14.6 kg| |global warming potential[CO2 eq]/ duringoperation|48.9 kg| |global warming potential[CO2 eq]/ after end of life<br>~~ee~~|-2.2 kg<br>~~ee~~| |Siemens Eco Profile(SEP)<br>~~ee~~|Siemens EcoTech<br>~~ee~~| |**reference code / according to IEC 81346-2**<br>~~ee~~|Q<br>~~ee~~| |**Approvals / Certificates**|| |**General Product Approval**|| 3VA20107KQ360AA0 Page 3/7 Subject to change without notice © Copyright Siemens 5/30/2026 **==> picture [510 x 429] intentionally omitted <==** **----- Start of picture text -----**<br> CCS (China Classifica- Miscellaneous<br>tion Society)<br>—— Ty Las RMIAS<br>other Dangerous goods Environment<br>Miscellaneous Confirmation Transport Information Environmental Con-<br>—— —____ FRAQC PASS eS firmations siemens ©i<br>Environment<br>Environmental Con-<br>firmations a<br>EPD<br>e Further information s<br>Information on the packaging<br>https://support.industry.siemens.com/cs/ww/en/view/109813875<br>Information for data generation and storage<br>https://support.industry.siemens.com/cs/ww/en/view/109995012<br>Information- and Downloadcenter (Catalogs, Brochures,…)<br>https://www.siemens.com/lowvoltage/catalogs<br>Industry Mall (Online ordering system)<br>https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3VA2010-7KQ36-0AA0<br>Service&Support (Manuals, Certificates, Characteristics, FAQs,...)<br>https://support.industry.siemens.com/cs/ww/en/ps/3VA2010-7KQ36-0AA0<br>Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)<br>https://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VA2010-7KQ36-0AA0<br>CAx-Online-Generator<br>https://www.siemens.com/cax<br>Tender specifications<br>https://www.siemens.com/specifications<br>Characteristic curves<br>https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no><br>**----- End of picture text -----**<br> 3VA20107KQ360AA0 Page 4/7 Subject to change without notice © Copyright Siemens 5/30/2026 **==> picture [308 x 331] intentionally omitted <==** **----- Start of picture text -----**<br> -Q<br>ETU860<br>! L<br>—_<br>I> S<br>5 [5 | | x<br>I>> I<br>I> I> I><br>7| 1 | _<br>G<br>I>> I>> I>><br>O EP P MF<br>;<br>I>> I>> I>><br>oT<br>tt<br>To<br>—><br>N-CT EFB RCD VT<br>:istaian<br>1 3 5<br>2 4 6 -X1 -X2 -X3 -X4<br>**----- End of picture text -----**<br> **last modified:** 5/25/2025 3VA20107KQ360AA0 Page 5/7 Subject to change without notice © Copyright Siemens 5/30/2026 3VA20107KQ360AA0 Page 6/7 Subject to change without notice © Copyright Siemens 5/30/2026 3VA20107KQ360AA0 Page 7/7 Subject to change without notice © Copyright Siemens 5/30/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →