3VA2010-7KP42-0AA0
Electronic Circuit Breaker, MCCB, 3VA2, 4P, 110 kA, 415 V, 100 A, Without Auxiliary Contact
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Electronic Circuit Breakers
- SVHC: To Be Advised
- Trip Time: -
- No. of Poles: 4 Pole
- Product Range: SENTRON 3VA2 Series
- Current Rating: 100A
- Supply Voltage: 690V
- Load Current Max: -
- Circuit Breaker Mounting: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1853.1 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3VA2010-7KP42-0AA0** **Data sheet** circuit breaker 3VA2 IEC Frame 100 breaking capacity class C Icu=110 kA @ 415 V 4-pole, line protection ETU850, LSI, In=100 A overload protection Ir=40 A...100 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In neutral conductor protection adjustable (OFF, up to 100%) nut keeper kit |**Model**|| |---|---| |product brand name|SENTRON| |product designation|Molded case circuit breaker| |design of theproduct|Lineprotection| |design of the overcurrent release|ETU850| |protection function of the overcurrent release|LSI| |number of poles|4| |**General technical data**|| |insulation voltage / rated value|800 V| |operatingvoltage / at AC / rated value|690 V| |power loss[W]/ maximum|7.7 W| |power loss [W] / for rated value of the current / at AC / in hot|2.57 W| |operatingstate /perpole|| |mechanical service life(operatingcycles)/ typical|25 000| |electrical endurance(operatingcycles)/ at AC-1 / at 380/415 V|15 000| |electrical endurance(operatingcycles)/ at AC-1 / at 690 V|10 500| |product feature / for neutral conductors / upgradable/retrofittable|No| |/ short-circuit and overloadproof|| |ground-fault monitoringversion|Without| |product function|| |● communication function|Yes| |● other measurement function|Yes| |Net Weight|3.2 kg| |**Current**|| |operational current|| |● at 40 °C|100 A| |● at 45 °C|100 A| |● at 50 °C|100 A| |● at 55 °C|100 A| |● at 60 °C|100 A| |● at 65 °C|100 A| |● at 70 °C|100 A| |**Switching capacity according to IEC 60947**|| |switchingcapacityclass of the circuit breaker|C| |maximum short-circuit current breakingcapacity (Icu)|| |● at 240 V|150 kA| Subject to change without notice © Copyright Siemens 3VA20107KP420AA0 Page 1/6 5/31/2026 ||● at 415 V|110 kA|| |---|---|---|---| ||● at 440 V|110 kA|| ||● at 500 V|85 kA|| ||● at 690 V|2 kA|| ||operatingshort-circuit current breakingcapacity (Ics)||| ||● at 240 V|150 kA|| ||● at 415 V|110 kA|| ||● at 440 V|110 kA|| ||● at 500 V|85 kA|| ||● at 690 V|2 kA|| ||short-circuit current makingcapacity (Icm)||| ||● at 240 V|330 kA|| ||● at 415 V|242 kA|| ||● at 440 V|242 kA|| ||● at 500 V|187 kA|| ||● at 690 V|3 kA|| ||**Adjustable parameters**||| ||product feature / for L-tripping/ can be switched on/off|No|| ||adjustable response value setting current (Ir) / of the L-trip / with<br>I2t characteristic||| ||● minimum|40 A|| ||● maximum|100 A|| ||adjustable response value delay time (tr) / for L-tripping / with I2t<br>characteristic||| ||● minimum|0.5 s|| ||● maximum|25 s|| ||adjustable response value setting current (Isd) / of S-trip / with<br>I0t characteristic||| ||● minimum|60 A|| ||● maximum|1 000 A|| ||adjustable response value setting current (Isd) / of S-trip / with<br>I2t characteristic||| ||● minimum|60 A|| ||● maximum|1 000 A|| ||adjustable response value delay time (tsd) / for S-tripping / with<br>I0t characteristic||| ||● minimum|0.05 s|| ||● maximum|0.5 s|| ||adjustable response value delay time (tsd) / for S-tripping / with<br>I2t characteristic||| ||● minimum|0.05 s|| ||● maximum|0.5 s|| ||adjustable response value settingcurrent(Ii)/ for I-tripping||| ||● minimum|150 A|| ||● maximum|1 200 A|| ||adjustable settingcurrent(InN)/ for N-tripping||| ||● minimum|20 A|| ||● maximum|100 A|| ||design of the N-conductorprotection|adjustable OFF; 20% to 100%|| ||product function /groundingprotection|No|| ||**Mechanical Design**||| ||product component||| ||● undervoltage release|No|| ||● voltage trigger|No|| ||● tripindicator|No|| ||height[in]|7.13 in|| ||height|181 mm|| ||width[in]|5.51 in|| ||width|140 mm|| ||depth[in]|3.39 in|| ||depth|86 mm|| Subject to change without notice © Copyright Siemens 3VA20107KP420AA0 Page 2/6 5/31/2026 |**Connections**<br>~~ee~~|**Connections**<br>~~ee~~|**Connections**<br>~~ee~~|**Connections**<br>~~ee~~|**Connections**<br>~~ee~~|**Connections**<br>~~ee~~| |---|---|---|---|---|---| |arrangement of electrical connectors / for main current circuit|Front terminal||||| |type of electrical connection / for main current circuit|on both sides nut keeper kit||||| |type of connectable conductor cross-sections / for flat-bar|13 x 1 mm||||| |terminal connection / minimum|||||| |type of connectable conductor cross-sections / for flat-bar|25 x 8 mm||||| |terminal connection / maximum|||||| |design of the surface / of the connections / on the top of the|tin||||| |switch(N, 1, 3, 5)<br>~~So~~|||||| |design of the surface / of the connections / on the bottom of the|tin||||| |switch(N, 2, 4, 6)|||||| |**Auxiliary circuit**|||||| |number of CO contacts / for auxiliarycontacts|0||||| |**Accessories**<br>~~er~~|||||| |product extension / optional / motor drive|Yes||||| |**Environmental conditions**<br>~~ee~~|||||| |protection class IP / on the front|IP40||||| |ambient temperature|||||| |● duringoperation / minimum|-25 °C||||| |● duringoperation / maximum|70 °C||||| |● duringstorage / minimum|-40 °C||||| |● duringstorage / maximum|80 °C||||| |**Environmental footprint**<br>~~ee~~|||||| |global warming potential[CO2 eq]/ total|61.814 k||61.814 kg||| |global warming potential[CO2 eq]/ duringmanufacturing|14.6 kg||||| |global warming potential[CO2 eq]/ duringoperation<br>global warming potential[CO2 eq]/ after end of life<br>~~re~~|48.9 kg<br>-2.2 kg||||| |Siemens Eco Profile(SEP)|Siemens EcoTech||||| |**reference code / according to IEC 81346-2**|Q||||| |**Approvals / Certificates**|||||| |**General Product Approval**|||||| |Miscellaneous<br>~~~~~~|||FAL||Confirmation<br>~~_~~| |**General Product Ap-**<br>**proval**<br>**EMV**<br>**Test Certificates**|||||**Maritime application**| |Miscellaneous<br>Cc<br>&<br>~~~~ ——~~||~~——~~|Special Test Certific-<br>ate<br>Type Test Certific-<br>ates/Test Report<br>~~——~~@||| |**Maritime application**|||||**other**| |©<br>z=<br>wv,|||@|CCS (China Classifica-<br>tion Society)<br>~~—~~|Miscellaneous| |**other**|||**Dangerous goods**|**Environment**|| |Miscellaneous<br>Confirmation|||Transport Information|Environmental Con-|| |||||firmations|| |**Environment**|||||| Subject to change without notice © Copyright Siemens 3VA20107KP420AA0 Page 3/6 5/31/2026 Environmental Confirmations ~~a~~ ## **Further information** **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/lowvoltage/catalogs **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3VA2010-7KP42-0AA0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3VA2010-7KP42-0AA0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)** https://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VA2010-7KP42-0AA0 **CAx-Online-Generator** https://www.siemens.com/cax **Tender specifications** https://www.siemens.com/specifications **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> Subject to change without notice © Copyright Siemens 3VA20107KP420AA0 Page 4/6 5/31/2026 **==> picture [259 x 330] intentionally omitted <==** **----- Start of picture text -----**<br> -Q<br>ctr —~\V_ Ve —~\__ ETU850<br>L<br>I> S<br>- REEEI I> I> I> I> | a I>> I<br>N N<br>PPT |r<br>I>> I>> I>> I>><br>P MF<br>TTT | &<br>——<br>Pp of [|]<br>qf |<br>| [|]<br>¢ |<br>|<br>T |<br>EFB RCD<br>| [|]<br>1 3 5 7<br>N<br>N<br>2 4 6 8 -X2 -X3<br>**----- End of picture text -----**<br> **last modified:** 4/3/2025 Subject to change without notice © Copyright Siemens 3VA20107KP420AA0 Page 5/6 5/31/2026 Subject to change without notice © Copyright Siemens 3VA20107KP420AA0 Page 6/6 5/31/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →