- Manufacturer: SIEMENS
- Product type: Electronic Circuit Breakers
- SVHC: To Be Advised
- Trip Time: -
- No. of Poles: 3 Pole
- Product Range: SENTRON 3VA2 Series
- Current Rating: 100A
- Supply Voltage: 690V
- Load Current Max: -
- Circuit Breaker Mounting: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1583.4 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3VA2010-7KP36-0AA0** **Data sheet** circuit breaker 3VA2 IEC Frame 100 breaking capacity class C Icu=110 kA @ 415 V 3-pole, line protection ETU850, LSI, In=100 A overload protection Ir=40 A...100 A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In neutral conductor protection optionally with external current transformer, up to 160% terminal connection |**Model**|| |---|---| |product brand name|SENTRON| |product designation|Molded case circuit breaker| |design of theproduct|Lineprotection| |design of the overcurrent release|ETU850| |protection function of the overcurrent release|LSI| |number of poles|3| |**General technical data**|| |insulation voltage / rated value|800 V| |operatingvoltage / at AC / rated value|690 V| |power loss[W]/ maximum|7.7 W| |power loss [W] / for rated value of the current / at AC / in hot|2.57 W| |operatingstate /perpole|| |mechanical service life(operatingcycles)/ typical|25 000| |electrical endurance(operatingcycles)/ at AC-1 / at 380/415 V|15 000| |electrical endurance(operatingcycles)/ at AC-1 / at 690 V|10 500| |product feature / for neutral conductors / upgradable/retrofittable|Yes| |/ short-circuit and overloadproof|| |ground-fault monitoringversion|Without| |product function|| |● communication function|Yes| |● other measurement function|Yes| |Net Weight|2.5 kg| |**Current**|| |operational current|| |● at 40 °C|100 A| |● at 45 °C|100 A| |● at 50 °C|100 A| |● at 55 °C|100 A| |● at 60 °C|100 A| |● at 65 °C|100 A| |● at 70 °C|100 A| |**Switching capacity according to IEC 60947**|| |switchingcapacityclass of the circuit breaker|C| |maximum short-circuit current breakingcapacity (Icu)|| |● at 240 V|150 kA| Subject to change without notice © Copyright Siemens 3VA20107KP360AA0 Page 1/4 5/30/2026 |● at 415 V|110 kA| |---|---| |● at 440 V|110 kA| |● at 500 V|85 kA| |● at 690 V|2 kA| |operatingshort-circuit current breakingcapacity (Ics)|| |● at 240 V|150 kA| |● at 415 V|110 kA| |● at 440 V|110 kA| |● at 500 V|85 kA| |● at 690 V|2 kA| |short-circuit current makingcapacity (Icm)|| |● at 240 V|330 kA| |● at 415 V|242 kA| |● at 440 V|242 kA| |● at 500 V|187 kA| |● at 690 V|3 kA| |**Adjustable parameters**|| |product feature / for L-tripping/ can be switched on/off|No| |adjustable response value setting current (Ir) / of the L-trip / with<br>I2t characteristic|| |● minimum|40 A| |● maximum|100 A| |adjustable response value delay time (tr) / for L-tripping / with I2t<br>characteristic|| |● minimum|0.5 s| |● maximum|25 s| |adjustable response value setting current (Isd) / of S-trip / with<br>I0t characteristic|| |● minimum|60 A| |● maximum|1 000 A| |adjustable response value setting current (Isd) / of S-trip / with<br>I2t characteristic|| |● minimum|60 A| |● maximum|1 000 A| |adjustable response value delay time (tsd) / for S-tripping / with<br>I0t characteristic|| |● minimum|0.05 s| |● maximum|0.5 s| |adjustable response value delay time (tsd) / for S-tripping / with<br>I2t characteristic|| |● minimum|0.05 s| |● maximum|0.5 s| |adjustable response value settingcurrent(Ii)/ for I-tripping|| |● minimum|150 A| |● maximum|1 200 A| |adjustable settingcurrent(InN)/ for N-tripping|| |● minimum|20 A| |● maximum|160 A| |design of the N-conductorprotection|adjustable OFF; 20% to 160%| |product function /groundingprotection|No| |**Mechanical Design**|| |product component|| |● undervoltage release|No| |● voltage trigger|No| |● tripindicator|No| |height[in]|7.13 in| |height|181 mm| |width[in]|4.13 in| |type of connectable conductor cross-sections / of the round<br>conductor terminal / stranded|1 x (6 - 120 mm²)| |width|105 mm| Subject to change without notice © Copyright Siemens 3VA20107KP360AA0 Page 2/4 5/30/2026 |depth[in]<br>depth<br>~~re~~|depth[in]<br>depth<br>~~re~~|depth[in]<br>depth<br>~~re~~|3.39 in<br>86 mm|3.39 in<br>86 mm|||| |---|---|---|---|---|---|---|---| |**Connections**|||||||| |arrangement of electrical connectors / for main current circuit|||Front terminal||||| |type of electrical connection / for main current circuit|||double-sided box terminal||||| |design of the surface / of the connections / on the top of the|||tin||||| |switch(N, 1, 3, 5)<br>~~Ce~~|||||||| |design of the surface / of the connections / on the bottom of the|||tin||||| |switch(N, 2, 4, 6)|||||||| |**Auxiliary circuit**|||||||| |number of CO contacts / for auxiliarycontacts|||0||||| |**Accessories**<br>~~er~~|||||||| |product extension / optional / motor drive|||Yes||||| |**Environmental conditions**<br>~~ee~~|||||||| |protection class IP / on the front|||IP40||||| |ambient temperature|||||||| |● duringoperation / minimum|||-25 °C||||| |● duringoperation / maximum|||70 °C||||| |● duringstorage / minimum|||-40 °C||||| |● duringstorage / maximum|||80 °C||||| |**Environmental footprint**<br>~~ee~~|||||||| |global warming potential[CO2 eq]/ total|||61.814 k||61.814 kg||| |global warming potential[CO2 eq]/ duringmanufacturing|||14.6 kg||||| |global warming potential[CO2 eq]/ duringoperation<br>global warming potential[CO2 eq]/ after end of life<br>~~re~~|||48.9 kg<br>-2.2 kg||||| |Siemens Eco Profile(SEP)|||Siemens EcoTech||||| |**reference code / according to IEC 81346-2**|||Q||||| |**Approvals / Certificates**|||||||| |**General Product Approval**|||||||| |aS|Miscellaneous<br>~~— ~~||||A|(§})|Confirmation| |**General Product Ap-**<br>**proval**<br>**EMV**|**Test Certificates**||||||**Maritime application**| |Cc<br>&|Miscellaneous<br>~~~~ ——~~||~~——~~|~~——~~|Special Test Certific-<br>ate<br>Type Test Certific-<br>ates/Test Report<br>~~——~~@||| |**Maritime application**|||||||**other**| |©<br>wv,|z=||||@|CCS (China Classifica-<br>tion Society)<br>~~—~~|Miscellaneous| |**other**|||||**Dangerous goods**|**Environment**|| |Miscellaneous<br>Confirmation|||||Transport Information|Environmental Con-|| |||||||firmations|| |**Environment**|||||||| Subject to change without notice © Copyright Siemens 3VA20107KP360AA0 Page 3/4 5/30/2026 Environmental Confirmations ~~—~~ **Further information** ~~OO~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/lowvoltage/catalogs **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3VA2010-7KP36-0AA0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3VA2010-7KP36-0AA0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)** https://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VA2010-7KP36-0AA0 **CAx-Online-Generator** https://www.siemens.com/cax **Tender specifications** https://www.siemens.com/specifications **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> ~~OO~~ **last modified:** 4/3/2025 Subject to change without notice © Copyright Siemens 3VA20107KP360AA0 Page 4/4 5/30/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →