3VA2010-6KQ36-0AA0
Electronic Circuit Breaker, MCCB, 3VA2, 3P, 85 kA, 415 V, 100 A, Without Auxiliary Contact
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Electronic Circuit Breakers
- SVHC: To Be Advised
- Trip Time: -
- No. of Poles: 3 Pole
- Product Range: SENTRON 3VA2 Series
- Current Rating: 100A
- Supply Voltage: 690V
- Load Current Max: -
- Circuit Breaker Mounting: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1717.0 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3VA2010-6KQ36-0AA0** **Data sheet** |circuit breaker 3VA2 IEC Frame 100 breaking capacity class H Icu=85 kA @ 415 V<br>3-pole, line protection ETU860, LSIG, In=100 A overload protection Ir=40 A...100 A<br>short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In neutral conductor protection<br>optionally with external current transformer, up to 160% ground-fault protection,<br>can be switched off Ig=0.2...1 x In, tg=0.05-0.8s terminal connection<br>**Model**<br>product brand name<br>SENTRON<br>product designation<br>Molded case circuit breaker<br>design of theproduct<br>Lineprotection<br>design of the overcurrent release<br>ETU860<br>protection function of the overcurrent release<br>LSIG<br>number of poles<br>3<br>**General technical data**<br>insulation voltage / rated value<br>800 V<br>operatingvoltage / at AC / rated value<br>690 V<br>power loss[W]/ maximum<br>13.5 W<br>power loss [W] / for rated value of the current / at AC / in hot<br>operatingstate /perpole<br>4.5 W<br>mechanical service life(operatingcycles)/ typical<br>25 000<br>electrical endurance(operatingcycles)/ at AC-1 / at 380/415 V<br>15 000<br>electrical endurance(operatingcycles)/ at AC-1 / at 690 V<br>10 500<br>product feature / for neutral conductors / upgradable/retrofittable<br>/ short-circuit and overloadproof<br>Yes<br>ground-fault monitoringversion<br>Summation current formation L-conductor<br>product function<br>● communication function<br>Yes<br>● other measurement function<br>Yes<br>Net Weight<br>2.5 kg<br>**Current**<br>operational current<br>● at 40 °C<br>100 A<br>● at 45 °C<br>100 A<br>● at 50 °C<br>100 A<br>● at 55 °C<br>100 A<br>● at 60 °C<br>100 A<br>● at 65 °C<br>100 A<br>● at 70 °C<br>100 A<br>**Switching capacity according to IEC 60947**<br>switchingcapacityclass of the circuit breaker<br>H<br>maximum short-circuit current breakingcapacity (Icu)<br>● at 240 V<br>110 kA<br>● at 415 V<br>85 kA<br>● at 440 V<br>85 kA<br>● at 500 V<br>55 kA<br>● at 690 V<br>2 kA<br>operatingshort-circuit current breakingcapacity (Ics)<br>● at 240 V<br>110 kA<br>● at 415 V<br>85 kA<br>● at 440 V<br>85 kA<br>● at 500 V<br>55 kA<br>● at 690 V<br>2 kA<br>short-circuit current makingcapacity (Icm)<br>● at 240 V<br>242 kA<br>Siemens~~@~~<br>EcoTech|circuit breaker 3VA2 IEC Frame 100 breaking capacity class H Icu=85 kA @ 415 V<br>3-pole, line protection ETU860, LSIG, In=100 A overload protection Ir=40 A...100 A<br>short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In neutral conductor protection<br>optionally with external current transformer, up to 160% ground-fault protection,<br>can be switched off Ig=0.2...1 x In, tg=0.05-0.8s terminal connection|| |---|---|---| ||H|| |||| ||110 kA|| ||85 kA|| ||85 kA|| ||55 kA|| ||2 kA|| |||| ||110 kA|| ||85 kA|| ||85 kA|| ||55 kA|| ||2 kA|| |||| ||242 kA|| 3VA20106KQ360AA0 Page 1/4 Subject to change without notice © Copyright Siemens 5/30/2026 ||● at 415 V|187 kA|| |---|---|---|---| ||● at 440 V|187 kA|| ||● at 500 V|121 kA|| ||● at 690 V|3 kA|| ||**Adjustable parameters**||| ||product feature / for L-tripping/ can be switched on/off|No|| ||adjustable response value setting current (Ir) / of the L-trip / with<br>I2t characteristic||| ||● minimum|40 A|| ||● maximum|100 A|| ||adjustable response value delay time (tr) / for L-tripping / with I2t<br>characteristic||| ||● minimum|0.5 s|| ||● maximum|25 s|| ||adjustable response value setting current (Isd) / of S-trip / with<br>I0t characteristic||| ||● minimum|60 A|| ||● maximum|1 000 A|| ||adjustable response value setting current (Isd) / of S-trip / with<br>I2t characteristic||| ||● minimum|60 A|| ||● maximum|1 000 A|| ||adjustable response value delay time (tsd) / for S-tripping / with<br>I0t characteristic||| ||● minimum|0.05 s|| ||● maximum|0.5 s|| ||adjustable response value delay time (tsd) / for S-tripping / with<br>I2t characteristic||| ||● minimum|0.05 s|| ||● maximum|0.5 s|| ||adjustable response value settingcurrent(Ii)/ for I-tripping||| ||● minimum|150 A|| ||● maximum|1 200 A|| ||adjustable current response value current / for G-tripping / with<br>standard characteristic||| ||● initial value|20 A|| ||● full-scale value|100 A|| ||adjustable response value delay time (tg) / for G-tripping / with<br>I0t characteristic||| ||● minimum|0.05 s|| ||● maximum|0.8 s|| ||adjustable response value setting current (Ig) / for G-tripping /<br>with I2t characteristic||| ||● minimum|20 A|| ||● maximum|100 A|| ||adjustable response value delay time (tg) / for G-tripping / with<br>I2t characteristic||| ||● minimum|0.05 s|| ||● maximum|0.8 s|| ||adjustable settingcurrent(InN)/ for N-tripping||| ||● minimum|20 A|| ||● maximum|160 A|| ||design of the N-conductorprotection|adjustable OFF; 20% to 160%|| ||product function /groundingprotection|Yes|| ||**Mechanical Design**||| ||product component||| ||● undervoltage release|No|| ||● voltage trigger|No|| ||● tripindicator|No|| ||height[in]|7.13 in|| ||height|181 mm|| ||width [in]|4.13 in|| 3VA20106KQ360AA0 Page 2/4 Subject to change without notice © Copyright Siemens 5/30/2026 |type of connectable conductor cross-sections / of the round|type of connectable conductor cross-sections / of the round||1 x (6 - 120 mm²)|1 x (6 - 120 mm²)|1 x (6 - 120 mm²)|1 x (6 - 120 mm²)||| |---|---|---|---|---|---|---|---|---| |conductor terminal / stranded||||||||| |width<br>depth[in]<br>~~re~~|||105 mm<br>3.39 in|||||| |depth|||86 mm|||||| |**Connections**||||||||| |arrangement of electrical connectors / for main current circuit|||Front terminal|||||| |type of electrical connection / for main current circuit|||double-sided box terminal|||||| |design of the surface / of the connections / on the top of the|||tin|||||| |switch(N, 1, 3, 5)<br>~~OS~~||||||||| |design of the surface / of the connections / on the bottom of the|||tin|||||| |switch(N, 2, 4, 6)||||||||| |**Auxiliary circuit**||||||||| |number of CO contacts / for auxiliarycontacts|||0|||||| |**Accessories**<br>~~ee~~||||||||| |product extension / optional / motor drive|||Yes|||||| |**Environmental conditions**<br>~~a~~||||||||| |protection class IP / on the front|||IP40|||||| |ambient temperature||||||||| |● duringoperation / minimum|||-25 °C|||||| |● duringoperation / maximum|||70 °C|||||| |● duringstorage / minimum|||-40 °C|||||| |● duringstorage / maximum|||80 °C|||||| |**Environmental footprint**<br>~~a~~||||||||| |global warming potential[CO2 eq]/ total|||61.814 k||61.814 kg|||| |global warming potential[CO2 eq]/ duringmanufacturing|||14.6 kg|||||| |global warming potential[CO2 eq]/ duringoperation<br>global warming potential[CO2 eq]/ after end of life<br>~~re~~|||48.9 kg<br>-2.2 kg|||||| |Siemens Eco Profile(SEP)|||Siemens EcoTech|||||| |**reference code / according to IEC 81346-2**|||Q|||||| |**Approvals / Certificates**||||||||| |**General Product Approval**||||||||| |&|Miscellaneous<br>~~|||||TT|(3)|Confirmation| |**General Product Ap-**<br>**proval**<br>**EMV**|**Test Certificates**|||||||**Maritime application**| |Cc<br>B&B~~~~~~|Miscellaneous<br>Special Test Certific-<br>ate<br>Type Test Certific-<br>ates/Test Report<br>~~~~~~<br>~~—~~<br>®@|||||||| |**Maritime application**||||||||**other**| |©<br>wv|=|||||8|CCS (China Classifica-<br>tion Society)<br>~~—~~|Miscellaneous| |**other**|||||**Dangerous goods**||**Environment**|| |Miscellaneous<br>Confirmation||||Transport Information|||Environmental Con-|| ||||||||firmations|| 3VA20106KQ360AA0 Page 3/4 Subject to change without notice © Copyright Siemens 5/30/2026 **Environment** Environmental Confirmations ~~—~~ ~~OO—C™rSC“‘CNCéiéCs~~ **Further information Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/lowvoltage/catalogs **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3VA2010-6KQ36-0AA0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3VA2010-6KQ36-0AA0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)** https://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VA2010-6KQ36-0AA0 **CAx-Online-Generator** https://www.siemens.com/cax **Tender specifications** https://www.siemens.com/specifications **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> ~~OO~~ **last modified:** 5/25/2025 3VA20106KQ360AA0 Page 4/4 Subject to change without notice © Copyright Siemens 5/30/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →