Image not available
Illustrative purposes only
3VA2010-6HM32-0AA0
Electronic Circuit Breaker, MCCB, 3VA2, 3P, 85 kA, 415 V, 100 A, Without Auxiliary Contact
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Electronic Circuit Breakers
- SVHC: To Be Advised
- Trip Time: -
- No. of Poles: 3 Pole
- Product Range: SENTRON 3VA2 Series
- Current Rating: 100A
- Supply Voltage: 690V
- Load Current Max: -
- Circuit Breaker Mounting: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1000.5 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3VA2010-6HM32-0AA0** **Data sheet** circuit breaker 3VA2 IEC Frame 100 breaking capacity class H Icu=85 kA @ 415 V 3-pole, line protection ETU330, LIG, In=100 A overload protection Ir=40 A...100 A short-circuit protection Ii=1.5...12 x In ground-fault protection Ig=0.2...1 x In, tg=0.1/0.3s nut keeper kit |**Model**|| |---|---| |product brand name|SENTRON| |product designation|Molded case circuit breaker| |design of theproduct|Lineprotection| |design of the overcurrent release|ETU330| |protection function of the overcurrent release|LIG| |number of poles|3| |**General technical data**|| |insulation voltage / rated value|800 V| |operatingvoltage / at AC / rated value|690 V| |power loss[W]/ maximum|13.5 W| |power loss [W] / for rated value of the current / at AC / in hot|4.5 W| |operatingstate /perpole|| |mechanical service life(operatingcycles)/ typical|25 000| |electrical endurance(operatingcycles)/ at AC-1 / at 380/415 V|15 000| |electrical endurance(operatingcycles)/ at AC-1 / at 690 V|10 500| |product feature / for neutral conductors / upgradable/retrofittable|No| |/ short-circuit and overloadproof|| |ground-fault monitoringversion|Summation current formation L-conductor| |product function|| |● communication function|No| |● other measurement function|No| |Net Weight|2.105 kg| |**Current**|| |operational current|| |● at 40 °C|100 A| |● at 45 °C|100 A| |● at 50 °C|100 A| |● at 55 °C|100 A| |● at 60 °C|100 A| |● at 65 °C|100 A| |● at 70 °C|100 A| |**Switching capacity according to IEC 60947**|| |switchingcapacityclass of the circuit breaker|H| |maximum short-circuit current breakingcapacity (Icu)|| |● at 240 V|110 kA| Subject to change without notice © Copyright Siemens 3VA20106HM320AA0 Page 1/6 5/30/2026 |● at 415 V|85 kA| |---|---| |● at 440 V|85 kA| |● at 500 V|55 kA| |● at 690 V|2 kA| |operatingshort-circuit current breakingcapacity (Ics)|| |● at 240 V|110 kA| |● at 415 V|85 kA| |● at 440 V|85 kA| |● at 500 V|55 kA| |● at 690 V|2 kA| |short-circuit current makingcapacity (Icm)|| |● at 240 V|242 kA| |● at 415 V|187 kA| |● at 440 V|187 kA| |● at 500 V|121 kA| |● at 690 V|3 kA| |**Adjustable parameters**|| |product feature / for L-tripping/ can be switched on/off|No| |adjustable response value setting current (Ir) / of the L-trip / with<br>I2t characteristic|| |● minimum|40 A| |● maximum|100 A| |adjustable response value delay time (tr) / for L-tripping / with I2t<br>characteristic|| |● minimum|0.5 s| |● maximum|17 s| |adjustable response value settingcurrent(Ii)/ for I-tripping|| |● minimum|150 A| |● maximum|1 200 A| |adjustable current response value current / for G-tripping / with<br>standard characteristic|| |● initial value|20 A| |● full-scale value|100 A| |adjustable response value delay time (tg) / for G-tripping / with<br>I0t characteristic|| |● minimum|0.1 s| |● maximum|0.3 s| |adjustable settingcurrent(InN)/ for N-tripping|| |● minimum|0 A| |● maximum|0 A| |product function /groundingprotection|Yes| |**Mechanical Design**|| |product component|| |● undervoltage release|No| |● voltage trigger|No| |● tripindicator|No| |height[in]|7.13 in| |height|181 mm| |width[in]|4.13 in| |width|105 mm| |depth[in]|3.39 in| |depth|86 mm| |**Connections**|| |arrangement of electrical connectors / for main current circuit|Front terminal| |type of electrical connection / for main current circuit|on both sides nut keeper kit| |type of connectable conductor cross-sections / for flat-bar<br>terminal connection / minimum|13 x 1 mm| |type of connectable conductor cross-sections / for flat-bar<br>terminal connection / maximum|25 x 8 mm| |design of the surface / of the connections / on the top of the<br>switch (N, 1, 3, 5)|tin| Subject to change without notice © Copyright Siemens 3VA20106HM320AA0 Page 2/6 5/30/2026 |design of the surface / of the connections / on the bottom of the|design of the surface / of the connections / on the bottom of the|design of the surface / of the connections / on the bottom of the||tin|||||| |---|---|---|---|---|---|---|---|---|---| |switch(N, 2, 4, 6)|||||||||| |**Auxiliary circuit**<br>~~ee~~|||||||||| |number of CO contacts / for auxiliarycontacts||||0|||||| |**Accessories**<br>~~ee~~|||||||||| |product extension / optional / motor drive||||Yes|||||| |**Environmental conditions**<br>~~ee~~|||||||||| |protection class IP / on the front||||IP40|||||| |ambient temperature|||||||||| |● duringoperation / minimum||||-25 °C|||||| |● duringoperation / maximum||||70 °C|||||| |● duringstorage / minimum||||-40 °C|||||| |● duringstorage / maximum||||80 °C|||||| |**Environmental footprint**<br>~~ee~~|||||||||| |global warming potential[CO2 eq]/ total||||61.814 k||61.814 kg|||| |global warming potential[CO2 eq]/ duringmanufacturing||||14.6 kg|||||| |global warming potential[CO2 eq]/ duringoperation||||48.9 kg|||||| |global warming potential[CO2 eq]/ after end of life||||-2.2 kg|||||| |Siemens Eco Profile(SEP)<br>~~re~~||||Siemens EcoTech|||||| |**reference code / according to IEC 81346-2**||||Q|||||| |**Approvals / Certificates**|||||||||| |**General Product Approval**|||||||||| |||Miscellaneous<br>~~A~~R|||||||Confirmation<br>~~_~~| |**General Product Ap-**<br>**proval**<br>**EMV**||**Test Certificates**|||||||**Maritime application**| |||Miscellaneous||||Special Test Certific-||Type Test Certific-|| ||||||||ate|ates/Test Report|| |**Maritime application**||||||||**other**|| ||||||CCS (China Classifica||CCS (China Classifica-|Miscellaneous|Miscellaneous| ||||||||tion Society)||| |PreriTas|||||||||| |**other**||**Dangerous goods**||||**Environment**|||| |Confirmation<br>~~—~~<br>QC PASS|Transport Information<br>Environmental Con-<br>firmations<br>~~——,_~~©<br>EcoTech||||||||s<br>EPD| |**Environment**|||||||||| |Environmental Con-|||||||||| |firmations|||||||||| |**Further information**<br>**Information on the packaging**<br>~~|~~|||||||||| |https://support.industry.siemens.com/cs/ww/en/view/109813875|||||||||| Subject to change without notice © Copyright Siemens 3VA20106HM320AA0 Page 3/6 5/30/2026 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/lowvoltage/catalogs **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3VA2010-6HM32-0AA0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3VA2010-6HM32-0AA0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)** https://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VA2010-6HM32-0AA0 **CAx-Online-Generator** https://www.siemens.com/cax **Tender specifications** https://www.siemens.com/specifications **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **==> picture [203 x 225] intentionally omitted <==** Subject to change without notice © Copyright Siemens 3VA20106HM320AA0 Page 4/6 5/30/2026 **==> picture [367 x 378] intentionally omitted <==** **----- Start of picture text -----**<br> -Q<br>ELr _ _ _ a ETU330<br>! L<br>I>> I<br>ee<br>G<br>I>> I>> I>><br>P EE<br>:<br>I>> I>> I>><br>| |<br>Hy |<br>| |<br>7 ||<br>|<br>1 |<br>EFB RCD<br>|<br>l is e 7<br>last modified: 4/3/2025 4<br>1 3 5<br>2 4 6 -X2 -X3<br>**----- End of picture text -----**<br> Subject to change without notice © Copyright Siemens 3VA20106HM320AA0 Page 5/6 5/30/2026 Subject to change without notice © Copyright Siemens 3VA20106HM320AA0 Page 6/6 5/30/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →