3VA2010-5KQ36-0AA0
Electronic Circuit Breaker, MCCB, 3VA2, 3P, 55 kA, 415 V, 100 A, Without Auxiliary Contact
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Electronic Circuit Breakers
- SVHC: To Be Advised
- Trip Time: -
- No. of Poles: 3 Pole
- Product Range: SENTRON 3VA2 Series
- Current Rating: 100A
- Supply Voltage: 690V
- Load Current Max: -
- Circuit Breaker Mounting: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1705.2 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3VA2010-5KQ36-0AA0**
**Data sheet**
|circuit breaker 3VA2 IEC Frame 100 breaking capacity class M Icu=55 kA @ 415 V<br>3-pole, line protection ETU860, LSIG, In=100 A overload protection Ir=40 A...100 A<br>short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In neutral conductor protection<br>optionally with external current transformer, up to 160% ground-fault protection,<br>can be switched off Ig=0.2...1 x In, tg=0.05-0.8s terminal connection<br>**Model**<br>product brand name<br>SENTRON<br>product designation<br>Molded case circuit breaker<br>design of theproduct<br>Lineprotection<br>design of the overcurrent release<br>ETU860<br>protection function of the overcurrent release<br>LSIG<br>number of poles<br>3<br>**General technical data**<br>insulation voltage / rated value<br>800 V<br>operatingvoltage / at AC / rated value<br>690 V<br>power loss[W]/ maximum<br>13.5 W<br>power loss [W] / for rated value of the current / at AC / in hot<br>operatingstate /perpole<br>4.5 W<br>mechanical service life(operatingcycles)/ typical<br>25 000<br>electrical endurance(operatingcycles)/ at AC-1 / at 380/415 V<br>15 000<br>electrical endurance(operatingcycles)/ at AC-1 / at 690 V<br>10 500<br>product feature / for neutral conductors / upgradable/retrofittable<br>/ short-circuit and overloadproof<br>Yes<br>ground-fault monitoringversion<br>Summation current formation L-conductor<br>product function<br>● communication function<br>Yes<br>● other measurement function<br>Yes<br>Net Weight<br>2.5 kg<br>**Current**<br>operational current<br>● at 40 °C<br>100 A<br>● at 45 °C<br>100 A<br>● at 50 °C<br>100 A<br>● at 55 °C<br>100 A<br>● at 60 °C<br>100 A<br>● at 65 °C<br>100 A<br>● at 70 °C<br>100 A<br>**Switching capacity according to IEC 60947**<br>switchingcapacityclass of the circuit breaker<br>M<br>maximum short-circuit current breakingcapacity (Icu)<br>● at 240 V<br>85 kA<br>● at 415 V<br>55 kA<br>● at 440 V<br>55 kA<br>● at 500 V<br>36 kA<br>● at 690 V<br>2 kA<br>operatingshort-circuit current breakingcapacity (Ics)<br>● at 240 V<br>85 kA<br>● at 415 V<br>55 kA<br>● at 440 V<br>55 kA<br>● at 500 V<br>36 kA<br>● at 690 V<br>2 kA<br>short-circuit current makingcapacity (Icm)<br>● at 240 V<br>187 kA<br>Siemens~~@~~<br>EcoTech|circuit breaker 3VA2 IEC Frame 100 breaking capacity class M Icu=55 kA @ 415 V<br>3-pole, line protection ETU860, LSIG, In=100 A overload protection Ir=40 A...100 A<br>short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In neutral conductor protection<br>optionally with external current transformer, up to 160% ground-fault protection,<br>can be switched off Ig=0.2...1 x In, tg=0.05-0.8s terminal connection||
|---|---|---|
||M||
||||
||85 kA||
||55 kA||
||55 kA||
||36 kA||
||2 kA||
||||
||85 kA||
||55 kA||
||55 kA||
||36 kA||
||2 kA||
||||
||187 kA||
3VA20105KQ360AA0 Page 1/6
Subject to change without notice © Copyright Siemens
5/30/2026
||● at 415 V|121 kA||
|---|---|---|---|
||● at 440 V|121 kA||
||● at 500 V|75.5 kA||
||● at 690 V|3 kA||
||**Adjustable parameters**|||
||product feature / for L-tripping/ can be switched on/off|No||
||adjustable response value setting current (Ir) / of the L-trip / with<br>I2t characteristic|||
||● minimum|40 A||
||● maximum|100 A||
||adjustable response value delay time (tr) / for L-tripping / with I2t<br>characteristic|||
||● minimum|0.5 s||
||● maximum|25 s||
||adjustable response value setting current (Isd) / of S-trip / with<br>I0t characteristic|||
||● minimum|60 A||
||● maximum|1 000 A||
||adjustable response value setting current (Isd) / of S-trip / with<br>I2t characteristic|||
||● minimum|60 A||
||● maximum|1 000 A||
||adjustable response value delay time (tsd) / for S-tripping / with<br>I0t characteristic|||
||● minimum|0.05 s||
||● maximum|0.5 s||
||adjustable response value delay time (tsd) / for S-tripping / with<br>I2t characteristic|||
||● minimum|0.05 s||
||● maximum|0.5 s||
||adjustable response value settingcurrent(Ii)/ for I-tripping|||
||● minimum|150 A||
||● maximum|1 200 A||
||adjustable current response value current / for G-tripping / with<br>standard characteristic|||
||● initial value|20 A||
||● full-scale value|100 A||
||adjustable response value delay time (tg) / for G-tripping / with<br>I0t characteristic|||
||● minimum|0.05 s||
||● maximum|0.8 s||
||adjustable response value setting current (Ig) / for G-tripping /<br>with I2t characteristic|||
||● minimum|20 A||
||● maximum|100 A||
||adjustable response value delay time (tg) / for G-tripping / with<br>I2t characteristic|||
||● minimum|0.05 s||
||● maximum|0.8 s||
||adjustable settingcurrent(InN)/ for N-tripping|||
||● minimum|20 A||
||● maximum|160 A||
||design of the N-conductorprotection|adjustable OFF; 20% to 160%||
||product function /groundingprotection|Yes||
||**Mechanical Design**|||
||product component|||
||● undervoltage release|No||
||● voltage trigger|No||
||● tripindicator|No||
||height[in]|7.13 in||
||height|181 mm||
||width [in]|4.13 in||
3VA20105KQ360AA0 Page 2/6
Subject to change without notice © Copyright Siemens
5/30/2026
|type of connectable conductor cross-sections / of the round|type of connectable conductor cross-sections / of the round|type of connectable conductor cross-sections / of the round|1 x (6 - 120 mm²)|1 x (6 - 120 mm²)|1 x (6 - 120 mm²)|||
|---|---|---|---|---|---|---|---|
|conductor terminal / stranded||||||||
|width|||105 mm|||||
|depth[in]<br>3.39 in<br>~~re~~||||||||
|depth|||86 mm|||||
|**Connections**||||||||
|arrangement of electrical connectors / for main current circuit|||Front terminal|||||
|type of electrical connection / for main current circuit|||double-sided box terminal|||||
|design of the surface / of the connections / on the top of the|||tin|||||
|switch(N, 1, 3, 5)||||||||
|design of the surface / of the connections / on the bottom of the|||tin|||||
|switch(N, 2, 4, 6)||||||||
|**Auxiliary circuit**<br>~~ee~~||||||||
|number of CO contacts / for auxiliarycontacts|||0|||||
|**Accessories**<br>~~ee~~||||||||
|product extension / optional / motor drive|||Yes|||||
|**Environmental conditions**<br>~~a~~||||||||
|protection class IP / on the front|||IP40|||||
|ambient temperature||||||||
|● duringoperation / minimum|||-25 °C|||||
|● duringoperation / maximum|||70 °C|||||
|● duringstorage / minimum|||-40 °C|||||
|● duringstorage / maximum|||80 °C|||||
|**Environmental footprint**<br>~~a~~||||||||
|global warming potential[CO2 eq]/ total|||61.814 k||61.814 kg|||
|global warming potential[CO2 eq]/ duringmanufacturing|||14.6 kg|||||
|global warming potential[CO2 eq]/ duringoperation|||48.9 kg|||||
|global warming potential[CO2 eq]/ after end of life|||-2.2 kg|||||
|Siemens Eco Profile(SEP)<br>Siemens EcoTech<br>~~re~~||||||||
|**reference code / according to IEC 81346-2**|||Q|||||
|**Approvals / Certificates**||||||||
|**General Product Approval**||||||||
|||Miscellaneous<br>~~~~~~|||FAL||Confirmation<br>~~_~~|
|**General Product Approval**|**EMV**||||**Test Certificates**|||
|UK<br>ca<br>Sf||@|||Miscellaneous<br>~~———_—_ ~~|Special Test Certific-<br>ate<br>Type Test Certific-<br>ates/Test Report<br> ~~os~~||
|**Maritime application**||||||||
||||||||CCS (China Classifica-|
||||||||tion Society)|
|7<br>a2||=|||os|os||
|**other**||||||**Dangerous goods**|**Environment**|
|Miscellaneous<br>Miscellaneous<br>Confirmation<br>~~ss~~||||||Transport Information|Environmental Con-|
||||||||firmations|
**Environment**
3VA20105KQ360AA0 Page 3/6
Subject to change without notice © Copyright Siemens
5/30/2026
firmations ~~—_—~~
## Environmental Confirmations
~~P~~ **Further information Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/lowvoltage/catalogs **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3VA2010-5KQ36-0AA0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3VA2010-5KQ36-0AA0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)** https://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VA2010-5KQ36-0AA0 **CAx-Online-Generator** https://www.siemens.com/cax **Tender specifications** https://www.siemens.com/specifications **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no>
3VA20105KQ360AA0 Page 4/6
Subject to change without notice © Copyright Siemens
5/30/2026
**==> picture [308 x 330] intentionally omitted <==**
**----- Start of picture text -----**<br>
-Q<br>ELr _ _ _ a ETU860<br>L<br>I> S<br>cs ( 5 . x<br>I>> I<br>I> I> I><br>71| |<br>G<br>I>> I>> I>><br>- P MF<br>I>> I>> I>><br>ae<br>f |<br>ft<br>c|<br>|<br>{|<br>N-CT EFB RCD VT<br>l ia P| alata<br>1 3 5<br>2 4 6 -X1 -X2 -X3 -X4<br>**----- End of picture text -----**<br>
**last modified:**
**==> picture [34 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
4/23/2026<br>**----- End of picture text -----**<br>
3VA20105KQ360AA0 Page 5/6
Subject to change without notice © Copyright Siemens
5/30/2026
3VA20105KQ360AA0 Page 6/6
Subject to change without notice © Copyright Siemens
5/30/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →