Image not available
Illustrative purposes only
3VA1010-2ED36-0AA0
Thermal Magnetic Circuit Breaker, MCCB, 3VA1, 3P, 16 kA, 415 V, 100 A, Without Auxiliary Contact
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- Product Range: SENTRON 3VA1 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 320.04 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3VA1010-2ED36-0AA0** **Data sheet** circuit breaker 3VA1 IEC Frame 100 breaking capacity class B Icu=16 kA @ 415 V 3-pole, line protection TM210, FTFM, In=100 A overload protection Ir=100 A permanently set short-circuit protection Ii=10 x In terminal connection |abd|circuit breaker 3VA1 IEC Frame 100 breaking capacity class B Icu=16 kA @ 415 V<br>3-pole, line protection TM210, FTFM, In=100 A overload protection Ir=100 A<br>permanently set short-circuit protection Ii=10 x In terminal connection| |---|---| |**Model**|| |product brand name|SENTRON| |product designation|Molded case circuit breaker| |design of theproduct|Lineprotection| |design of the overcurrent release|TM210| |protection function of the overcurrent release|LI| |number of poles|3| |**General technical data**<br>~~|~~|| |insulation voltage / rated value<br>~~|~~|800 V<br>~~|~~| |operatingvoltage / at DC / rated value|500 V| |operatingvoltage / at AC / rated value|690 V| |power loss[W]/ maximum|25 W| |power loss [W] / for rated value of the current / at AC / in hot<br>operatingstate /perpole|8.33 W| |mechanical service life(operatingcycles)/ typical|20 000| |electrical endurance(operatingcycles)/ at AC-1 / at 380/415 V|9 000| |electrical endurance(operatingcycles)/ at AC-1 / at 690 V|6 300| |product feature / for neutral conductors / upgradable/retrofittable<br>/ short-circuit and overloadproof|No| |ground-fault monitoringversion|Without| |product function|| |● communication function|No| |● other measurement function|No| |Net Weight|982g| |**Current**<br>~~|~~|| |operational current<br>~~|~~|~~|~~| |● at 40 °C|100 A| |● at 45 °C|100 A| |● at 50 °C|100 A| |● at 55 °C|98 A| |● at 60 °C|96 A| |● at 65 °C|94 A| |● at 70 °C|91 A| |**Switching capacity according to IEC 60947**<br>~~|~~|| |switchingcapacityclass of the circuit breaker<br>~~|~~|B<br>~~|~~| |maximum short-circuit current breakingcapacity (Icu)|| |● at 240 V|25 kA| |● at 415 V|16 kA| |● at 440 V|8 kA| Subject to change without notice © Copyright Siemens 3VA10102ED360AA0 Page 1/6 6/4/2026 ||● at 500 V|5 kA|| |---|---|---|---| ||● at 690 V|5 kA|| ||operatingshort-circuit current breakingcapacity (Ics)||| ||● at 240 V|25 kA|| ||● at 415 V|16 kA|| ||● at 440 V|8 kA|| ||● at 500 V|5 kA|| ||● at 690 V|5 kA|| ||short-circuit current makingcapacity (Icm)||| ||● at 240 V|52.5 kA|| ||● at 415 V|32 kA|| ||● at 440 V|13.6 kA|| ||● at 500 V|7.5 kA|| ||● at 690 V|7.5 kA|| ||design of short-circuit protection|For switching power values in DC networks, see the 3VA molded case circuit<br>breaker device manual; link to be found under Service & Support in the last<br>chapter|| ||**Adjustable parameters**||| ||product feature / for L-tripping/ can be switched on/off|No|| ||adjustable response value setting current (Ir) / of the L-trip / with<br>I2t characteristic||| ||● minimum|100 A|| ||● maximum|100 A|| ||adjustable response value delay time (tr) / for L-tripping / with I2t<br>characteristic||| ||● minimum|1 s|| ||● maximum|1 s|| ||adjustable response value settingcurrent(Ii)/ for I-tripping||| ||● minimum|1 000 A|| ||● maximum|1 000 A|| ||adjustable settingcurrent(InN)/ for N-tripping||| ||● minimum|0 A|| ||● maximum|0 A|| ||product function /groundingprotection|No|| ||**Mechanical Design**||| ||product component||| ||● undervoltage release|No|| ||● voltage trigger|No|| ||● tripindicator|No|| ||height[in]|5.12 in|| ||height|130 mm|| ||width[in]|3 in|| ||type of connectable conductor cross-sections / of the round<br>conductor terminal / stranded|1 x (1,5 - 70 mm²)|| ||width|76.2 mm|| ||depth[in]|2.76 in|| ||depth|70 mm|| ||**Connections**||| ||arrangement of electrical connectors / for main current circuit|Front terminal|| ||type of electrical connection / for main current circuit|box terminal on both sides|| ||design of the surface / of the connections / on the top of the<br>switch(N, 1, 3, 5)|Silver|| ||design of the surface / of the connections / on the bottom of the<br>switch(N, 2, 4, 6)|Tin|| ||**Auxiliary circuit**||| ||number of CO contacts / for auxiliarycontacts|0|| ||**Accessories**||| ||product extension / optional / motor drive|No|| ||**Environmental conditions**||| ||protection class IP / on the front|IP40|| ||ambient temperature||| Subject to change without notice © Copyright Siemens 3VA10102ED360AA0 Page 2/6 6/4/2026 ● during operation / minimum -25 °C ● during operation / maximum 70 °C ● during storage / minimum -40 °C ● during storage / maximum 80 °C ~~a~~ **Environmental footprint** Environmental Product Declaration(EPD) Yes global warming potential [CO2 eq] / total 190 kg global warming potential [CO2 eq] / during manufacturing 4.67 kg global warming potential [CO2 eq] / during operation 186 kg global warming potential [CO2 eq] / after end of life -0.826 kg **reference code / according to IEC 81346-2** Q ~~ee~~ **Approvals / Certificates General Product Approval** ~~t~~ Miscellaneous t Confirmation **General Product Approval EMV Test Certificates** Miscellaneous Special Test CertificType Test CertificcAca Sf£§ @ ~~TO~~ ate ates/Test Report **Maritime application** - CCS (China Classifica tion Society) **other Environment** Miscellaneous Confirmation Environmental ConEnvironmental Confirmations firmations ~~a ——.~~ TC . QC PASS EPD **Environment** = EPD ~~e~~ **Further information** ~~e~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/lowvoltage/catalogs **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3VA1010-2ED36-0AA0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3VA1010-2ED36-0AA0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)** https://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VA1010-2ED36-0AA0 **CAx-Online-Generator** https://www.siemens.com/cax Subject to change without notice © Copyright Siemens 3VA10102ED360AA0 Page 3/6 6/4/2026 **Tender specifications** https://www.siemens.com/specifications **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **==> picture [203 x 225] intentionally omitted <==** **==> picture [380 x 345] intentionally omitted <==** **----- Start of picture text -----**<br> -Q<br>I>> I>> I>><br>1 3 5<br>2 4 6<br>**----- End of picture text -----**<br> Subject to change without notice © Copyright Siemens 3VA10102ED360AA0 Page 4/6 6/4/2026 **last modified:** 8/7/2025 Subject to change without notice © Copyright Siemens 3VA10102ED360AA0 Page 5/6 6/4/2026 Subject to change without notice © Copyright Siemens 3VA10102ED360AA0 Page 6/6 6/4/2026
Updated at April 27, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 420,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →