Image not available
Illustrative purposes only
3UG4651-2AW30
Speed Monitoring Relay, 0.1 RPM to 2200 RPM, 24 V to 240 V, 86 mm x 22.5 mm x 103 mm, SIRIUS Series
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Controller Accessories
- SVHC: To Be Advised
- Product Range: SIRIUS 3UG4 Series
- Current Rating: 4A
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 275.79 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3UG4651-2AW30** **Data sheet** !!! product phase-out !!! the preferred successor is 3UG5651-2CW30 digital monitoring relay speed monitoring from 0.1 to 2200 r/min overshoot and undershoot 24 to 240 V AC/DC 50 to 60 Hz DC and AC ON-delay 1 to 900 s tripping delay 0.1 to 99.9 s hysteresis 0.1 to 99 r/min 1 changeover contact with or without fault buffer spring-loaded connection system |**product brand name**|SIRIUS| |---|---| |**product designation**|Speed monitoringrelaywith digital setting| |**product type designation**|3UG4| |**General technical data**<br>~~|~~|| |**product function**|RPM monitoringrelay| |**design of the display**|LCD| ||| |● apparentpower consumption at AC|| |— at 24 V maximum|4 VA| |— at 240 V maximum|9 VA| |**insulation voltage**|| |**● for overvoltage category III according to IEC 60664**|| |— with degree ofpollution 3 rated value|300 V| |**degree ofpollution**|3| |type of voltage of the control supplyvoltage|AC/DC| |**surge voltage resistance rated value**|4 kV| |**shock resistance according to IEC 60068-2-27**|sinusoidal half-wave 15g/ 11 ms| |**mechanical service life(operating cycles) typical**|10 000 000| |electrical endurance(operatingcycles)at AC-15 at 230 V typical|100 000| |**reference code according to IEC 81346-2**|K| |**relative repeat accuracy**|1 %| |**Substance Prohibitance(day/month/year)**|05/01/2012| |**SVHC substance name**|Lead CAS-No. 7439-92-1| ||Lead monoxide (lead oxide) CAS-No. 1317-36-8| ||2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-| ||10-5| ||Melamine CAS-No. 108-78-1| ||6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1| |||Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1<br>6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1| |---|---|---| ||**Net Weight**|0.154g| |**Product Function**<br>~~|~~||| ||**product function**|| ||● standstill monitoring|No| ||● rotation speed monitoring|Yes| ||● error memory|Yes| ||● adjustable open/closed-circuit currentprinciple|Yes| ||● external reset|Yes| ||● auto-RESET|Yes| ||● manual RESET|Yes| ||suitabilityfor use safety-related circuits|No| |**Control circuit/ Control**<br>~~OO~~<br>~~—CtrsSCSC“‘CCNC;CCéC~~||| 3UG46512AW30 Page 1/4 Subject to change without notice © Copyright Siemens 6/2/2026 |**control supply voltage at AC**|| |---|---| |● at 50 Hz rated value|24 ... 240 V| |● at 60 Hz rated value|24 ... 240 V| |**control supply voltage at DC rated value**|24 ... 240 V| |**operating range factor control supply voltage rated value at**<br>**DC**|| |● initial value|0.8| |● full-scale value|1.1| |**operating range factor control supply voltage rated value at**<br>**AC at 50 Hz**|| |● initial value|1.1| |● full-scale value|0.8| |**operating range factor control supply voltage rated value at**<br>**AC at 60 Hz**|| |● initial value|1.1| |● full-scale value|0.8| |**Measuring circuit**|| |**measurable line frequency**|50 ... 60 Hz| |**adjustable response delay time**|| |● when starting|1 ... 900 s| |● with lower or upper limit violation|0.1 ... 99.9 s| |**buffering time in the event ofpower failure minimum**|10 ms| |**accuracy of digital display**|+/- 1 Digit| |**Precision**|| |**relative metering precision**|10 %| |**Communication/ Protocol**|| |protocol is supported IO-Link protocol|No| |**Auxiliary circuit**|| |number of NC contacts delayed switching|0| |number of NO contacts delayed switching|0| |number of CO contacts delayed switching|1| |**operating frequency with 3RT2 contactor maximum**|5 000 1/h| |**Inputs/ Outputs**|| |design of input feedback input|No| |**number of outputs as contact-affected switching element**|| |● for signalingfunction|| |— instantaneous contact|0| |— delayed switching|1| |● safety-related|| |— delayed switching|0| |— instantaneous contact|0| |**number of outputs as contact-less semiconductor**<br>**switching element**|| |● for signalingfunction|| |— delayed switching|0| |— instantaneous contact|0| |● safety-related|| |— delayed switching|0| |— instantaneous contact|0| |**ampacity of the output relay at AC-15**|| |● at 250 V at 50/60 Hz|3 A| |**ampacity of the output relay at DC-13**|| |● at 24 V|1 A| |● at 125 V|0.2 A| |● at 250 V|0.1 A| |**operational current at 17 V minimum**|5 mA| |**continuous current of the DIAZED fuse link of the output**<br>**relay**|4 A| |**Electromagnetic compatibility**|| |**conducted interference**|| 3UG46512AW30 Page 2/4 Subject to change without notice © Copyright Siemens 6/2/2026 ||● due to burst accordingto IEC 61000-4-4|2 kV|| |---|---|---|---| ||● due to conductor-earth surge accordingto IEC 61000-4-5|2 kV|| ||● due to conductor-conductor surge according to IEC<br>61000-4-5|1 kV|| ||**field-based interference according to IEC 61000-4-3**|10 V/m|| ||**electrostatic discharge according to IEC 61000-4-2**|6 kV contact discharge / 8 kV air discharge|| ||**Galvanic isolation**||| ||**galvanic isolation**||| ||● between input and output|Yes|| ||● between the outputs|No|| ||IEC 61508||| ||SafetyIntegrityLevel(SIL)accordingto IEC 61508|without|| ||Electrical Safety||| ||**protection class IP on the front according to IEC 60529**|IP20|| ||**Connections/ Terminals**||| ||**product component removable terminal for auxiliary and**<br>**control circuit**|Yes|| ||**type of electrical connection**|spring-loaded terminals|| ||**type of connectable conductor cross-sections**||| ||● solid|2x(0.25 ... 1.5 mm²)|| ||● finelystranded with core endprocessing|2 x(0.25 ... 1.5 mm²)|| ||● finelystranded without core endprocessing|2x(0.25 ... 1.5 mm²)|| ||● for AWG cables solid|2x(24 ... 16)|| ||● for AWG cables stranded|2x(24 ... 16)|| ||**connectable conductor cross-section**||| ||● solid|0.25 ... 1.5 mm²|| ||● finelystranded with core endprocessing|0.25 ... 1.5 mm²|| ||● finelystranded without core endprocessing|0.25 ... 1.5 mm²|| ||**AWG number as coded connectable conductor cross**<br>**section**||| ||● solid|24 ... 16|| ||● stranded|24 ... 16|| ||**Installation/ mounting/ dimensions**||| ||**mounting position**|any|| ||**fastening method**|screw and snap-on mounting|| ||**height**|86 mm|| ||**width**|22.5 mm|| ||**depth**|103 mm|| ||**required spacing**||| ||● with side-by-side mounting||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|0 mm|| ||— downwards|0 mm|| ||— at the side|0 mm|| ||● forgroundedparts||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|0 mm|| ||— at the side|0 mm|| ||— downwards|0 mm|| ||● for liveparts||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|0 mm|| ||— downwards|0 mm|| ||— at the side|0 mm|| ||**Ambient conditions**||| ||installation altitude at height above sea level maximum|2 000 m|| ||**ambient temperature**||| 3UG46512AW30 Page 3/4 Subject to change without notice © Copyright Siemens 6/2/2026 ● during operation -25 ... +60 °C ● during storage -40 ... +80 °C ● during transport -40 ... +80 °C **Approvals Certificates** ~~ee~~ Environmental Product Declaration ● global warming potential [CO2 eq] / during manufacturing 4.44 kg ● global warming potential [CO2 eq] / during sales 0.0341 kg ● global warming potential [CO2 eq] / during operation 13.7 kg ● global warming potential [CO2 eq] / after end of life -1.06 kg ● global warming potential [CO2 eq] / total 17.1 kg **Environment General Product Approval** Environmental Confirmations **General Product ApEMV Test Certificates Maritime application proval** - - Type Test Certific Special Test Certific ates/Test Report ate **Maritime application other Railway** Confirmation Confirmation Special Test Certificate me ce ~~s) i~~ **Further information** ~~(iss~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3UG4651-2AW30 **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3UG4651-2AW30 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3UG4651-2AW30 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3UG4651-2AW30&lang=en **last modified:** 4/4/2026 3UG46512AW30 Page 4/4 Subject to change without notice © Copyright Siemens 6/2/2026
Updated at April 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →