Image not available
Illustrative purposes only
3UG4651-1AA30
Speed Monitoring Relay, 0.1 RPM to 2200 RPM, 24 V, IP20, 86 mm x 22.5 mm x 102 mm, SIRIUS Series
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type:
- SVHC: To Be Advised
- Product Range: SIRIUS 3UG4 Series
- Current Rating: 4A
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 243.6 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3UG4651-1AA30** **Data sheet** !!! product phase-out !!! the preferred successor is 3UG5651-1CW30 digital monitoring relay speed monitoring from 0.1 to 2200 r/min overshoot and undershoot supply voltage: 24 V AC/DC 50 to 60 Hz DC and AC without electrical isolation to the measuring circuit ON-delay 1 to 900 s tripping delay 0.1 to 99.9 s hysteresis 0.1 to 99 r/min 1 changeover contact with or without fault buffer |a<br>——_<br>mg<br>Paar|!!! product phase-out !!! the preferred successor is 3UG5651-1CW30 digital<br>monitoring relay speed monitoring from 0.1 to 2200 r/min overshoot and<br>undershoot supply voltage: 24 V AC/DC 50 to 60 Hz DC and AC without electrical<br>isolation to the measuring circuit ON-delay 1 to 900 s tripping delay 0.1 to 99.9 s<br>hysteresis 0.1 to 99 r/min 1 changeover contact with or without fault buffer| |---|---| |**product brand name**|SIRIUS| |**product designation**|Speed monitoringrelaywith digital setting| |**product type designation**|3UG4| |**General technical data**|| |**product function**|RPM monitoringrelay| |**design of the display**|LCD| ||| |● apparentpower consumption at AC|| |— at 24 V maximum|2.5 VA| |**insulation voltage**|| |**● for overvoltage category III according to IEC 60664**|| |— with degree ofpollution 3 rated value|300 V| |**degree ofpollution**|3| |type of voltage of the control supplyvoltage|AC/DC| |**surge voltage resistance rated value**|4 kV| |**shock resistance according to IEC 60068-2-27**|sinusoidal half-wave 15g/ 11 ms| |**mechanical service life(operating cycles) typical**|10 000 000| |electrical endurance(operatingcycles)at AC-15 at 230 V typical|100 000| |**reference code according to IEC 81346-2**|K| |**relative repeat accuracy**|1 %| |**Substance Prohibitance(day/month/year)**|05/01/2012| |**SVHC substance name**|Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>Melamine CAS-No. 108-78-1<br>6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1| |**Net Weight**|0.165 kg| |**Product Function**|| |**product function**|| |● standstill monitoring|No| |● rotation speed monitoring|Yes| |● error memory|Yes| |● adjustable open/closed-circuit currentprinciple|Yes| |● external reset|Yes| |● auto-RESET|Yes| |● manual RESET|Yes| |suitabilityfor use safety-related circuits|No| |**Control circuit/ Control**|| |**control supply voltage at AC**|| |● at 50 Hz rated value|24 V| |● at 60 Hz rated value|24 V| 3UG46511AA30 Page 1/4 Subject to change without notice © Copyright Siemens 6/1/2026 |**control supply voltage at DC rated value**|24 V| |---|---| |**operating range factor control supply voltage rated value at**<br>**DC**|| |● initial value|0.8| |● full-scale value|1.1| |**operating range factor control supply voltage rated value at**<br>**AC at 50 Hz**|| |● initial value|1.1| |● full-scale value|0.8| |**operating range factor control supply voltage rated value at**<br>**AC at 60 Hz**|| |● initial value|1.1| |● full-scale value|0.8| |**Measuring circuit**|| |**measurable line frequency**|50 ... 60 Hz| |**adjustable response delay time**|| |● when starting|1 ... 900 s| |● with lower or upper limit violation|0.1 ... 99.9 s| |**buffering time in the event ofpower failure minimum**|10 ms| |**accuracy of digital display**|+/- 1 Digit| |**Precision**|| |**relative metering precision**|10 %| |**Communication/ Protocol**|| |protocol is supported IO-Link protocol|No| |**Auxiliary circuit**|| |number of NC contacts delayed switching|0| |number of NO contacts delayed switching|0| |number of CO contacts delayed switching|1| |**operating frequency with 3RT2 contactor maximum**|5 000 1/h| |**Inputs/ Outputs**|| |design of input feedback input|No| |**number of outputs as contact-affected switching element**|| |● for signalingfunction|| |— instantaneous contact|0| |— delayed switching|1| |● safety-related|| |— delayed switching|0| |— instantaneous contact|0| |**number of outputs as contact-less semiconductor**<br>**switching element**|| |● for signalingfunction|| |— delayed switching|0| |— instantaneous contact|0| |● safety-related|| |— delayed switching|0| |— instantaneous contact|0| |**ampacity of the output relay at AC-15**|| |● at 250 V at 50/60 Hz|3 A| |**ampacity of the output relay at DC-13**|| |● at 24 V|1 A| |● at 125 V|0.2 A| |● at 250 V|0.1 A| |**operational current at 17 V minimum**|5 mA| |**continuous current of the DIAZED fuse link of the output**<br>**relay**|4 A| |**Electromagnetic compatibility**|| |**conducted interference**|| |● due to burst accordingto IEC 61000-4-4|2 kV| |● due to conductor-earth surge accordingto IEC 61000-4-5|2 kV| |● due to conductor-conductor surge according to IEC|1 kV| 3UG46511AA30 Page 2/4 Subject to change without notice © Copyright Siemens 6/1/2026 |61000-4-5|| |---|---| |**field-based interference according to IEC 61000-4-3**|10 V/m| |**electrostatic discharge according to IEC 61000-4-2**|6 kV contact discharge / 8 kV air discharge| |**Galvanic isolation**|| |**galvanic isolation**|| |● between input and output|Yes| |● between the outputs|No| |IEC 61508|| |SafetyIntegrityLevel(SIL)accordingto IEC 61508|without| |Electrical Safety|| |**protection class IP on the front according to IEC 60529**|IP20| |**Connections/ Terminals**|| |**product component removable terminal for auxiliary and**<br>**control circuit**|Yes| |**type of electrical connection**|screw terminal| |**type of connectable conductor cross-sections**|| |● solid|1x(0.5 ... 4 mm²), 2x(0.5 ... 2.5 mm²)| |● finelystranded with core endprocessing|1x(0.5 ... 2.5 mm²), 2x(0.5 ... 1.5 mm²)| |● for AWG cables solid|2x(20 ... 14)| |● for AWG cables stranded|2x(20 ... 14)| |**connectable conductor cross-section**|| |● solid|0.5 ... 4 mm²| |● finelystranded with core endprocessing|0.5 ... 2.5 mm²| |**AWG number as coded connectable conductor cross**<br>**section**|| |● solid|20 ... 14| |● stranded|20 ... 14| |tighteningtorque with screw-type terminals|0.8 ... 1.2 N·m| |**Installation/ mounting/ dimensions**|| |**mounting position**|any| |**fastening method**|screw and snap-on mounting| |**height**|86 mm| |**width**|22.5 mm| |**depth**|102 mm| |**required spacing**|| |● with side-by-side mounting|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|0 mm| |— downwards|0 mm| |— at the side|0 mm| |● forgroundedparts|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|0 mm| |— at the side|0 mm| |— downwards|0 mm| |● for liveparts|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|0 mm| |— downwards|0 mm| |— at the side|0 mm| |**Ambient conditions**|| |installation altitude at height above sea level maximum|2 000 m| |**ambient temperature**|| |● duringoperation|-25 ... +60 °C| |● duringstorage|-40 ... +80 °C| |● during transport|-40 ... +80 °C| 3UG46511AA30 Page 3/4 Subject to change without notice © Copyright Siemens 6/1/2026 **==> picture [510 x 579] intentionally omitted <==** **----- Start of picture text -----**<br> Approvals Certificates<br>SS Environmental Product Declaration<br>● global warming potential [CO2 eq] / during manufacturing 4.44 kg<br>● global warming potential [CO2 eq] / during sales 0.0341 kg<br>● global warming potential [CO2 eq] / during operation 13.7 kg<br>● global warming potential [CO2 eq] / after end of life -1.06 kg<br>● global warming potential [CO2 eq] / total 17.1 kg<br>Environment General Product Approval<br>Environmental Con-<br>firmations<br>—— © UK<br>EPD @ fH ¢E4<br>General Product Ap- EMV Test Certificates Maritime application<br>proval<br>- -<br>Special Test Certific Type Test Certific<br>ate ates/Test Report<br>ce [; &<br>Maritime application other Railway<br>Confirmation Confirmation Special Test Certific-<br>ate<br>ee a<br>e Further information e<br>Information on the packaging<br>https://support.industry.siemens.com/cs/ww/en/view/109813875<br>Information for data generation and storage<br>https://support.industry.siemens.com/cs/ww/en/view/109995012<br>Information- and Downloadcenter (Catalogs, Brochures,…)<br>https://www.siemens.com/ic10<br>Industry Mall (Online ordering system)<br>https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3UG4651-1AA30<br>Cax online generator<br>https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3UG4651-1AA30<br>Service&Support (Manuals, Certificates, Characteristics, FAQs,...)<br>https://support.industry.siemens.com/cs/ww/en/ps/3UG4651-1AA30<br>Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)<br>https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3UG4651-1AA30&lang=en<br>last modified: 4/4/2026<br>**----- End of picture text -----**<br> 3UG46511AA30 Page 4/4 Subject to change without notice © Copyright Siemens 6/1/2026
Updated at March 31, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →