Image not available
Illustrative purposes only
3UF7113-1AA00-0
Module, Current Measuring, 20A to 200A, SIRIUS Series, 110 to 690 VAC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Current Sensors
- Product Range: SIRIUS Series
- Sensor Output Type: -
- Current Measuring Range AC: 20A to 200A
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 318.32 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3UF7113-1AA00-0** **Data sheet** Current/voltage measuring module Set current 20...200 A voltage measurement up to 690 V, overall width 120 mm, straight-through transformer |**product brand name**|SIRIUS| |---|---| |**product designation**|Current/voltage measuringmodule| |**General technical data**<br>~~|~~|| |**size of the circuit-breaker**|S6| |**product function**|| |● current measurement|Yes| |● voltage measurement|Yes| |● activepower measurement|Yes| |● energymeasurement|Yes| |● frequencymeasurement|No| |**current measuring range extension with external current**|No| |**transformers**|| |**measurable supply voltage between the line conductors at**|690 V| |**AC maximum rated value**|| |**product component**|| |● input for thermistor connection|No| |**consumed activepower**|0.3 W| |**insulation voltage**|| |● with degree ofpollution 3 at AC rated value|690 V| |● for wires of main circuit according to IEC 60947-1 rated|6 kV| |value|| |**surge voltage resistance rated value**|8 000 V| |**shock resistance according to IEC 60068-2-27**|15g/ 11 ms| |**vibration resistance**|1 … 6 Hz / 15 mm; 6 … 500 Hz / 2g| |**reference code according to IEC 81346-2**|F| |**Substance Prohibitance(day/month/year)**|05/28/2009| |**SVHC substance name**|Lead monoxide (lead oxide) CAS-No. 1317-36-8| ||2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-| ||10-5| ||Melamine CAS-No. 108-78-1| |**Net Weight**|0.69 kg| |---|---| |**Electromagnetic compatibility**<br>~~|~~|| |EMC emitted interference accordingto IEC 60947-1|class A| |EMC immunityaccordingto IEC 60947-1|corresponds to degree of severity3| |**conducted interference**|| |● due to burst accordingto IEC 61000-4-4|2 kV| |● due to conductor-earth surge accordingto IEC 61000-4-5|2 kV| |● due to conductor-conductor surge according to IEC|1 kV| |61000-4-5|| |**field-based interference according to IEC 61000-4-3**|10 V/m| |**Inputs/ Outputs**<br>~~ee~~|| Subject to change without notice © Copyright Siemens 3UF71131AA000 Page 1/5 6/4/2026 |**number of outputs as contact-affected switching element**|0| |---|---| |**Protective and monitoring functions**|| |**product function**|| |●power factor monitoring|Yes| |●ground-fault monitoring|No| |● voltage detection|Yes| |**trip class**|CLASS 5E| |**product function**|| |● current detection|Yes| |● overload protection|Yes| |**Installation/ mounting/ dimensions**|| |**mounting position**|any| |**fastening method**|screw and snap-on mounting| |**height**|95 mm| |**width**|120 mm| |**depth**|145 mm| |**required spacing**|| |● top|30 mm| |● bottom|30 mm| |● left|0 mm| |● right|0 mm| |**diameter of inlet opening**|25 mm| |**diameter of inlet opening for current measurement**|25 mm| |**Connections/ Terminals**|| |**type of electrical connection**|| |● for main current circuit|straight-through transformers| |● for auxiliaryand control circuit|screw-type terminals| |**type of electrical connection at the measurement inputs for**<br>**voltage**|screw-type terminals| |**type of connectable conductor cross-sections at the**<br>**measurement inputs for voltage**|| |● finelystranded with core endprocessing|1x(0.5 ... 2.5 mm²), 2x(0.5 ... 1.5 mm²)| |● solid|1x(0.5 ... 4 mm²), 2x(0.5 ... 2.5 mm²)| |● for AWG cables solid|1x(20 ... 14), 2x(20 ... 14)| |● for AWG cables stranded|1x(20 ... 14), 2x(20 ... 16)| |**tightening torque at the measurement inputs for voltage**|0.8 ... 1.2 N·m| |**tightening torque [lbf·in] at the measurement inputs for**<br>**voltage**|7 ... 10.3 lbf·in| |**Ambient conditions**|| |**installation altitude at height above sea level**|| |● 1 maximum|2 000 m| |● 2 maximum|3 000 m; max. +50 °C(noprotective separation)| |● 3 maximum|4 000 m; max. +40 °C(noprotective separation)| |**ambient temperature**|| |● duringoperation|-25 ... +60 °C| |● duringstorage|-40 ... +80 °C| |● duringtransport|-40 ... +80 °C| |**environmental category**|| |● during operation according to IEC 60721|3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3<br>(no salt mist), 3S2(sand must notget into the devices), 3M6| |● during storage according to IEC 60721|1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2<br>(sand must notget into the devices), 1M4| |● duringtransport accordingto IEC 60721|2K2, 2C1, 2S1, 2M2| |relative humidityduringoperation|5 ... 95 %| |**Short-circuit protection**|| |**product function short circuitprotection**|No| |IEC 61508|| |SafetyIntegrityLevel(SIL)accordingto IEC 61508|1| |**ATEX**|| |**certificate of suitability**|| Subject to change without notice © Copyright Siemens 3UF71131AA000 Page 2/5 6/4/2026 |● accordingto ATEX directive 2014/34/EU|||BVS 06 ATEX F001|BVS 06 ATEX F001|BVS 06 ATEX F001|||| |---|---|---|---|---|---|---|---|---| |explosion device group and category according to ATEX|||II (2) G, II (2 ) D, I (M2)|II (2) G, II (2 ) D, I (M2)|II (2) G, II (2 ) D, I (M2)|||| |directive 2014/34/EU||||||||| |**Main circuit**<br>~~ee~~||||||||| |**number ofpoles for main current circuit**|||3|||||| |**adjustable current response value current of the current-**|||20 ... 200 A|20 ... 200 A||||| |**dependent overload release**||||||||| |**operating voltage**||||||||| |● at AC||||||||| |— at 50 Hz rated value|||110 ... 690 V|||||| |— at 60 Hz rated value|||110 ... 690 V|||||| |**operating frequency rated value**|||50 ... 60 Hz|50 ... 60 Hz||||| |**Control circuit/ Control**<br>~~ee~~||||||||| |**type of voltage**|||AC|||||| |**Approvals Certificates**<br>~~ee~~||||||||| |**Environment**|**General Product Approval**||**General Product Approval**|||||| |Environmental Con-||||||||| |firmations||||||||| |||||||||| |**General Product Approval**|**EMV**|||||**For use in hazardous locations**|**For use in hazardous locations**|| |Cc<br>ca|kc||||&®|©||| |**For use in hazardous locations**||||**Test Certificates**|**Test Certificates**|||| |€x)<br>CE|Miscellaneous|||Special Test Certific-<br>ate||Type Test Certific-<br>ates/Test Report|Special Test Certific|Special Test Certific-<br>ate| |**Maritime application**||||||**other**||| |e|=||||@|Confirmation<br> G~~l~~||| |**other**<br>**Industrial Communication**||||||||| |Confirmation||||||||| |||||||||| |**Further information**<br>~~ee~~||||||||| |**Information on the packaging**||||||||| |https://support.industry.siemens.com/cs/ww/en/view/109813875||||||||| |**Information for data generation and storage**||||||||| |https://support.industry.siemens.com/cs/ww/en/view/109995012||||||||| |**Information- and Downloadcenter (Catalogs, Brochures,…)**||||||||| |https://www.siemens.com/ic10||||||||| |**Industry Mall (Online ordering system)**||||||||| |https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3UF7113-1AA00-0||||||||| |**Cax online generator**||||||||| |https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3UF7113-1AA00-0||||||||| |**Service&Support (Manuals, Certificates, Characteristics, FAQs,...)**||||||||| Subject to change without notice © Copyright Siemens 3UF71131AA000 Page 3/5 6/4/2026 https://support.industry.siemens.com/cs/ww/en/ps/3UF7113-1AA00-0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3UF7113-1AA00-0&lang=en **==> picture [203 x 225] intentionally omitted <==** **==> picture [432 x 345] intentionally omitted <==** **----- Start of picture text -----**<br> -B<br>Sys<br>Logic<br>SIMOCODE PRO<br>(V) (V) (V)<br>L1 L2 L3 L1 L2 L3<br>T1 T2 T3<br>**----- End of picture text -----**<br> Subject to change without notice © Copyright Siemens 3UF71131AA000 Page 4/5 6/4/2026 **last modified:** 4/4/2026 Subject to change without notice © Copyright Siemens 3UF71131AA000 Page 5/5 6/4/2026
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →