Image not available
Illustrative purposes only
3UF7111-1AA01-0
Module, Current Measuring, 3A to 40A, SIRIUS Series, 110 to 690 VAC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Current Sensors
- Product Range: SIRIUS Series
- Sensor Output Type: -
- Current Measuring Range AC: 3A to 40A
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 198.36 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3UF7111-1AA01-0** **Data sheet** Current/voltage measuring module V2; Set current 3...40 A, Voltage measurement up to 690 V, Overall width 45 mm, Straight-through transformer, basic unit required pro V PB, pro V MR, pro V PN or pro V EIP ||Current/voltage measuring module V2; Set current 3...40 A, Voltage measurement<br>up to 690 V, Overall width 45 mm, Straight-through transformer, basic unit required<br>pro V PB, pro V MR, pro V PN or pro V EIP| |---|---| |**product brand name**|SIMOCODE| |**product designation**|Current/voltage measuringmodule| |**product type designation**|IUM| |**General technical data**|| |**measuring procedure**|RMS value measurement| |**size of the circuit-breaker**|S00, S0| |**product function**|| |● current measurement|Yes| |● voltage measurement|Yes| |● activepower measurement|Yes| |● energymeasurement|Yes| |● frequencymeasurement|Yes| |**measuring procedure for current measurement**|TRMS| |**current measuring range extension with external current**<br>**transformers**|Yes| |**measuring procedure for voltage measurement**|TRMS| |**measurable supply voltage between the line conductors at**<br>**AC maximum rated value**|690 V| |**product component**|| |● input for thermistor connection|No| |**consumed activepower**|0.5 W| |**insulation voltage**|| |● with degree ofpollution 3 at AC rated value|690 V| |● for wires of main circuit according to IEC 60947-1 rated<br>value|6 kV| |**surge voltage resistance rated value**|6 000 V| |**shock resistance according to IEC 60068-2-27**|15g/ 11 ms; with basic unit snapped on| |**vibration resistance**|1 … 6 Hz / 15 mm; 6 … 500 Hz / 2g; with basic unit snapped on: 1g| |**reference code according to IEC 81346-2**|F| |**Substance Prohibitance(day/month/year)**|05/28/2009| |**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1| |**Net Weight**|0.194 kg| |**Electromagnetic compatibility**|| |EMC emitted interference accordingto IEC 60947-1|class A| |EMC immunityaccordingto IEC 60947-1|corresponds to degree of severity3| |**conducted interference**|| |● due to burst according to IEC 61000-4-4|2 kV| Subject to change without notice © Copyright Siemens 3UF71111AA010 Page 1/6 5/29/2026 ||● due to conductor-earth surge accordingto IEC 61000-4-5|2 kV|| |---|---|---|---| ||● due to conductor-conductor surge according to IEC<br>61000-4-5|1 kV|| ||**field-based interference according to IEC 61000-4-3**|10 V/m|| ||**Inputs/ Outputs**||| ||**number of outputs as contact-affected switching element**|0|| ||**Protective and monitoring functions**||| ||**product function**||| ||●power factor monitoring|Yes|| ||●ground-fault monitoring|Yes|| ||● voltage detection|Yes|| ||**trip class**|CLASS 5E|| ||**product function**||| ||● current detection|Yes|| ||● overload protection|Yes|| ||**Precision**||| ||**measuring precision**||| ||● of frequency measurement|+/- 1.5 %, 2.25 A ... 80 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos<br>phi(0.5...1), 50/60 Hz, 25 °C|| ||● for current measurement 1|+/- 1.5 %, in range 2.25 A ... 80 A, in range 0.85 x 110 V ... 1.1 x 690 V (line-to-<br>line voltages), 50/60 Hz, 25 °C|| ||● for current measurement 2|+/- 3%, in range 80 A ... 320 A, in range 0.85 x 110 V ... 1.1 x 690 V (line-to-line<br>voltages), 50/60 Hz, 25 °C|| ||● for voltage measurement 1|+/- 1.5 %, in range 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), 50/60 Hz,<br>25 °C|| ||● at cos phi-measurement 1|+/- 1.5 %, 7.5 A ... 230 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos<br>phi(0.5...1), 50/60 Hz, 25 °C|| ||● at cos phi-measurement 2|+/- 5%, 80 A ... 320 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-<br>phi(0.5...1), 50/60 Hz, 25 °C|| ||● for active power measurement 1|+/- 5%, 2.25 A ... 80 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-<br>phi(0.5...1), 50/60 Hz, 25 °C|| ||● for active power measurement 2|+/- 10%, 80 A ... 320 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-<br>phi(0.5...1), 50/60 Hz, 25 °C|| ||● for energy measurement 1|+/- 5%, 2.25 A ... 80 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-<br>phi(0.5...1), 50/60 Hz, 25 °C|| ||● for energy measurement 2|+/- 10%, 80 A ... 320 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-<br>phi(0.5...1), 50/60 Hz, 25 °C|| ||● for apparent power measurement 1|+/- 3%, 2.25 A ... 80 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-<br>phi(0.5...1), 50/60 Hz, 25 °C|| ||● for apparent power measurement 2|+/- 1.5%, 2.25 A ... 80 A, 0.85 x 110 V ... 1.1 x 690 V (line-to-line voltages), cos-<br>phi(0.5...1), 50/60 Hz, 25 °C|| ||**accuracy of ground-fault monitoring**|In the range 30 % .. 120 %/Is: +/- 10 % (Class CI-A), in range 15 % .. 30 % Ie:<br>+/- 25 %(Class CI-B), both values acc. to IEC 60947-1 Annex T|| ||**temperature driftper °C**|0.01 %/°C; Reference temperature: 25°C|| ||**measured variable frequency**|45 ... 65 Hz|| ||**Installation/ mounting/ dimensions**||| ||**mounting position**|any|| ||**fastening method**|screw and snap-on mounting|| ||**height**|84 mm|| ||**width**|45 mm|| ||**depth**|64 mm|| ||**required spacing**||| ||● top|30 mm|| ||● bottom|30 mm|| ||● left|0 mm|| ||● right|0 mm|| ||**diameter of inlet opening**|7.5 mm|| ||**diameter of inlet opening for current measurement**|7.5 mm|| ||**Connections/ Terminals**||| ||**type of electrical connection**||| ||● for main current circuit|straight-through transformers|| ||● for auxiliaryand control circuit|screw-type terminals|| ||**type of electrical connection at the measurement inputs for**|screw-type terminals|| Subject to change without notice © Copyright Siemens 3UF71111AA010 Page 2/6 5/29/2026 ## **voltage** |**voltagegee**|**voltagegee**|| |---|---|---| |**type of connectable conductor cross-sections at the**<br>**measurement inputs for voltage**||| |● finelystranded with core endprocessing||1x(0.25 ... 2.5 mm²), 2x(0.25 ... 1.0 mm²)| |● solid||1x(0.25 ... 2.5 mm²), 2x(0.25 ... 1.0 mm²)| |● for AWG cables solid||1x(24 ... 14), 2x(24 ... 18)| |● for AWG cables stranded||1x(20 ... 14), 2x(20 ... 16)| |**tightening torque at the measurement inputs for voltage**||0.5 ... 0.6 N·m| |**tightening torque [lbf·in] at the measurement inputs for**<br>**voltage**||4.4 ... 5.3 lbf·in| |**Ambient conditions**<br>~~ee~~||| |**installation altitude at height above sea level**<br>~~ee~~||~~ee~~| |● 1 maximum||2 000 m| |● 2 maximum||3 000 m; max. +50 °C(noprotective separation)| |● 3 maximum||4 000 m; max. +40 °C(noprotective separation)| |**ambient temperature**||| |● duringoperation||-25 ... +60 °C| |● duringstorage||-40 ... +80 °C| |● duringtransport||-40 ... +80 °C| |**environmental category**||| |● during operation according to IEC 60721||3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3<br>(no salt mist), 3S2(sand must notget into the devices), 3M6| |● during storage according to IEC 60721||1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2<br>(sand must notget into the devices), 1M4| |● duringtransport accordingto IEC 60721<br>~~re~~||2K2, 2C1, 2S1, 2M2<br>~~re~~| |relative humidityduringoperation<br>~~re~~||10 ... 95 %<br>~~re~~| |**Short-circuit protection**||| |**product function short circuitprotection**<br>~~P|~~||No<br>~~P|~~| |IEC 61508<br>~~P|~~||| |SafetyIntegrityLevel(SIL)accordingto IEC 61508<br>~~P|~~||1<br>~~P|~~| |**ATEX**<br>~~a~~||| |**certificate of suitability**<br>~~a~~||~~a~~| |● accordingto ATEX directive 2014/34/EU||BVS 06 ATEX F001| |● accordingto UKCA||ITS21UKEX0464| |explosion device group and category according to ATEX<br>directive 2014/34/EU||II (2) G, II (2 ) D, I (M2)| |**Galvanic isolation**<br>~~a~~||| |**(electrically) protective separation according to IEC 60947-1**<br>~~a~~||All circuits with protective separation (double creepage paths and clearances),<br>the information in the "Protective Separation" test report, No. A0258, must be<br>observed(link see further information)<br>~~a~~| |**Main circuit**<br>~~ee~~||| |**number ofpoles for main current circuit**<br>~~ee~~||3<br>~~ee~~| |**adjustable current response value current of the current-**<br>**dependent overload release**||3 ... 40 A| |**operating voltage**||| |● at AC||| |— at 50 Hz rated value||110 ... 690 V| |— at 60 Hz rated value<br>~~re~~||110 ... 690 V<br>~~re~~| |**operating frequency rated value**<br>~~re~~||50 ... 60 Hz<br>~~re~~| |**Control circuit/ Control**||| |**type of voltage**||AC| |**inrush current maximum**||400 A; 10 x Io| |**Approvals Certificates**<br>~~rrr~~||| |**Environment**<br>~~rrr~~|**General Product Approval**<br>~~rrr~~|| Subject to change without notice © Copyright Siemens 3UF71111AA010 Page 3/6 5/29/2026 **==> picture [493 x 205] intentionally omitted <==** **----- Start of picture text -----**<br> For use in hazardous locations Test Certificates<br>Miscellaneous Special Test Certific- Type Test Certific- Special Test Certific-<br>ate ates/Test Report ate<br>€x) TT TO<br>Maritime application other<br>© clovesSE ea oO”. ee Confirmation<br>other Industrial Communication<br>Confirmation<br>**----- End of picture text -----**<br> **Further information** ~~i~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3UF7111-1AA01-0 **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3UF7111-1AA01-0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3UF7111-1AA01-0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3UF7111-1AA01-0&lang=en Subject to change without notice © Copyright Siemens 3UF71111AA010 Page 4/6 5/29/2026 Subject to change without notice © Copyright Siemens 3UF71111AA010 Page 5/6 5/29/2026 **==> picture [425 x 381] intentionally omitted <==** **----- Start of picture text -----**<br> i. -,----jJ_-J_J-__-_____-<br>-F<br>SIEMENS<br>|<br>|<br>| im<br>Logic<br>|<br>SIMOCODE PRO<br>|<br>el<br>|<br>|<br>|<br>aee<br>last modified: 4/4/2026 4<br>L1 L2 L3 L1 L2 L3<br>T1 T2 T3<br>**----- End of picture text -----**<br> Subject to change without notice © Copyright Siemens 3UF71111AA010 Page 6/6 5/29/2026
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →