3UF7103-1AA00-0
Module, Current Measuring, 20A to 200A, SIRIUS Series, 110 to 690 VAC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Current Sensors
- Product Range: SIRIUS Series
- Sensor Output Type: -
- Current Measuring Range AC: 20A to 200A
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 223.59 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3UF7103-1AA00-0** **Data sheet** Current measuring module, Set current 20...200 A overall width 120 mm, straightthrough transformer ||Current measuring module, Set current 20...200 A overall width 120 mm, straight-<br>through transformer| |---|---| |**product brand name**|SIMOCODE| |**product designation**|Current measuringmodule| |**product type designation**|IM| |**General technical data**<br>~~|~~|| |**size of the circuit-breaker**<br>~~|~~|S6<br>~~|~~| |**product function**|| |● current measurement|Yes| |● voltage measurement|No| |● activepower measurement|No| |● energymeasurement|No| |● frequencymeasurement|No| |**product component**|| |● input for thermistor connection|No| |**consumed activepower**|0.2 W| |**insulation voltage**|| |● with degree ofpollution 3 at AC rated value|690 V| |● for wires of main circuit according to IEC 60947-1 rated<br>value|8 kV| |**surge voltage resistance rated value**|8 000 V| |**shock resistance according to IEC 60068-2-27**|15g/ 11 ms| |**vibration resistance**|1 … 6 Hz / 15 mm; 6 … 500 Hz / 2g| |**reference code according to IEC 81346-2**|F| |**Substance Prohibitance(day/month/year)**|07/01/2006| |**SVHC substance name**|Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1| |**Net Weight**|634g| |**Electromagnetic compatibility**<br>~~|~~|| |EMC emitted interference accordingto IEC 60947-1<br>~~|~~|class A<br>~~|~~| |EMC immunityaccordingto IEC 60947-1|corresponds to degree of severity3| |**conducted interference**|| |● due to burst accordingto IEC 61000-4-4|2 kV| |● due to conductor-earth surge accordingto IEC 61000-4-5|2 kV| |● due to conductor-conductor surge according to IEC<br>61000-4-5|1 kV| |**field-based interference according to IEC 61000-4-3**|10 V/m| |**Inputs/ Outputs**<br>~~|~~|| |**number of outputs as contact-affected switching element**<br>~~|~~<br>~~OO~~|0<br>~~|~~| |**Protective and monitoring functions**<br>~~OO~~<br>~~—CtSCSC“‘:_CCSC‘iésC~~|| Subject to change without notice © Copyright Siemens 3UF71031AA000 Page 1/5 5/29/2026 |**product function**|| |---|---| |●power factor monitoring|No| |●ground-fault monitoring|No| |● voltage detection|No| |**trip class**|CLASS 5E| |**product function**|| |● current detection|Yes| |● overload protection|Yes| |**Installation/ mounting/ dimensions**|| |**mounting position**|any| |**fastening method**|screw and snap-on mounting| |**height**|95 mm| |**width**|120 mm| |**depth**|145 mm| |**required spacing**|| |● top|30 mm| |● bottom|30 mm| |● left|0 mm| |● right|0 mm| |**diameter of inlet opening**|25 mm| |**diameter of inlet opening for current measurement**|25 mm| |**Connections/ Terminals**|| |**type of electrical connection**|| |● for main current circuit|straight-through transformers| |**Ambient conditions**|| |**installation altitude at height above sea level**|| |● 1 maximum|2 000 m| |● 2 maximum|3 000 m; max. +50 °C(noprotective separation)| |● 3 maximum|4 000 m; max. +40 °C(noprotective separation)| |**ambient temperature**|| |● duringoperation|-25 ... +60 °C| |● duringstorage|-40 ... +80 °C| |● duringtransport|-40 ... +80 °C| |**environmental category**|| |● during operation according to IEC 60721|3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3<br>(no salt mist), 3S2(sand must notget into the devices), 3M6| |● during storage according to IEC 60721|1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2<br>(sand must notget into the devices), 1M4| |● duringtransport accordingto IEC 60721|2K2, 2C1, 2S1, 2M2| |relative humidityduringoperation|5 ... 95 %| |**Short-circuit protection**|| |**product function short circuitprotection**|No| |IEC 61508|| |SafetyIntegrityLevel(SIL)accordingto IEC 61508|1| |**ATEX**|| |**certificate of suitability**|| |● accordingto ATEX directive 2014/34/EU|BVS 06 ATEX F001| |● accordingto UKCA|ITS21UKEX0464| |explosion device group and category according to ATEX<br>directive 2014/34/EU|II (2) G, II (2 ) D, I (M2)| |**Galvanic isolation**|| |**(electrically) protective separation according to IEC 60947-1**|All circuits with protective separation (double creepage paths and clearances),<br>the information in the "Protective Separation" test report, No. A0258, must be<br>observed(link see further information)| |**Main circuit**|| |**number ofpoles for main current circuit**|3| |**adjustable current response value current of the current-**<br>**dependent overload release**|20 ... 200 A| |**operating voltage**|| |● at AC|| Subject to change without notice © Copyright Siemens 3UF71031AA000 Page 2/5 5/29/2026 — at 50 Hz rated value 110 ... 690 V — at 60 Hz rated value 110 ... 690 V **operating frequency rated value** 50 ... 60 Hz **Control circuit/ Control** ~~a~~ **type of voltage** AC ~~a~~ **Approvals Certificates Environment General Product Approval** Environmental Con- ~~—~~ firmations EPDa «&) (us EAL **General Product Approval EMV For use in hazardous locations** Cce UKes Cc @B ® **For use in hazardous locations Test Certificates Maritime application** - - Type Test Certific Special Test Certific ates/Test Report ate €x)= ~~—_——_~~ © = **Maritime application other Industrial Communication** ~~——~~ Confirmation Confirmation —_ Nat QC PASS **Further information Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3UF7103-1AA00-0 **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3UF7103-1AA00-0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3UF7103-1AA00-0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3UF7103-1AA00-0&lang=en Subject to change without notice © Copyright Siemens 3UF71031AA000 Page 3/5 5/29/2026 **==> picture [372 x 378] intentionally omitted <==** **----- Start of picture text -----**<br> _ _ _ oe<br>-F<br>SIEMENS<br>|<br>|<br>|<br>|<br>|<br>Logic / \<br>|<br>| SIMOCODE PRO<br>|<br>_<br>|<br>|<br>|<br>ee _ _ |<br>4/4/2026 4<br>L1 L2 L3<br>T1 T2 T3<br>**----- End of picture text -----**<br> **last modified:** Subject to change without notice © Copyright Siemens 3UF71031AA000 Page 4/5 5/29/2026 Subject to change without notice © Copyright Siemens 3UF71031AA000 Page 5/5 5/29/2026
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →