Image not available
Illustrative purposes only
3UF7101-1AA00-0
Current Sensor, 2.4 A to 25 A, 110 to 690 VAC, 3 Poles, SIRIUS Series
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Current Sensors
- SVHC: To Be Advised
- Product Range: SIRIUS Series
- Sensor Output Type: -
- Current Measuring Range AC: 2.4A to 25A
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 105.27 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3UF7101-1AA00-0** **Data sheet** Current measuring module, Set current 2.4...25 A Overall width 45 mm, straightthrough transformer |Current measuring module, Set current 2.4...25 A Overall width 45 mm, straight-<br>through transformer<br>**product brand name**<br>SIMOCODE<br>**product designation**<br>Current measuringmodule<br>**product type designation**<br>IM<br>**General technical data**<br>**size of the circuit-breaker**<br>S00, S0<br>**product function**<br>● current measurement<br>Yes<br>● voltage measurement<br>No<br>● activepower measurement<br>No<br>● energymeasurement<br>No<br>● frequencymeasurement<br>No<br>**product component**<br>● input for thermistor connection<br>No<br>**consumed activepower**<br>0.2 W<br>**insulation voltage**<br>● with degree ofpollution 3 at AC rated value<br>690 V<br>● for wires of main circuit according to IEC 60947-1 rated<br>value<br>6 kV<br>**surge voltage resistance rated value**<br>6 000 V<br>**shock resistance according to IEC 60068-2-27**<br>15g/ 11 ms<br>**vibration resistance**<br>1 … 6 Hz / 15 mm; 6 … 500 Hz / 2g<br>**reference code according to IEC 81346-2**<br>F<br>**Substance Prohibitance(day/month/year)**<br>05/28/2009<br>**SVHC substance name**<br>Lead CAS-No. 7439-92-1<br>Lead monoxide(lead oxide)CAS-No. 1317-36-8<br>**Net Weight**<br>0.16 kg<br>**Electromagnetic compatibility**<br>EMC emitted interference accordingto IEC 60947-1<br>class A<br>EMC immunityaccordingto IEC 60947-1<br>corresponds to degree of severity3<br>**conducted interference**<br>● due to burst accordingto IEC 61000-4-4<br>2 kV<br>● due to conductor-earth surge accordingto IEC 61000-4-5<br>2 kV<br>● due to conductor-conductor surge according to IEC<br>61000-4-5<br>1 kV<br>**field-based interference according to IEC 61000-4-3**<br>10 V/m<br>**Inputs/ Outputs**<br>**number of outputs as contact-affected switching element**<br>0<br>**Protective and monitoring functions**<br>**product function**<br>● power factor monitoring<br>No<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~|Current measuring module, Set current 2.4...25 A Overall width 45 mm, straight-<br>through transformer|| |---|---|---| ||SIMOCODE|| ||Current measuringmodule|| ||IM|| ||~~|~~|| ||No|| Subject to change without notice © Copyright Siemens 3UF71011AA000 Page 1/5 5/29/2026 |●ground-fault monitoring|No| |---|---| |● voltage detection|No| |**trip class**|CLASS 5E| |**product function**|| |● current detection|Yes| |● overload protection|Yes| |**Installation/ mounting/ dimensions**|| |**mounting position**|any| |**fastening method**|screw and snap-on mounting| |**height**|84 mm| |**width**|45 mm| |**depth**|45 mm| |**required spacing**|| |● top|30 mm| |● bottom|30 mm| |● left|0 mm| |● right|0 mm| |**diameter of inlet opening**|7.5 mm| |**diameter of inlet opening for current measurement**|7.5 mm| |**Connections/ Terminals**|| |**type of electrical connection**|| |● for main current circuit|straight-through transformers| |**Ambient conditions**|| |**installation altitude at height above sea level**|| |● 1 maximum|2 000 m| |● 2 maximum|3 000 m; max. +50 °C(noprotective separation)| |● 3 maximum|4 000 m; max. +40 °C(noprotective separation)| |**ambient temperature**|| |● duringoperation|-25 ... +60 °C| |● duringstorage|-40 ... +80 °C| |● duringtransport|-40 ... +80 °C| |**environmental category**|| |● during operation according to IEC 60721|3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3<br>(no salt mist), 3S2(sand must notget into the devices), 3M6| |● during storage according to IEC 60721|1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2<br>(sand must notget into the devices), 1M4| |● duringtransport accordingto IEC 60721|2K2, 2C1, 2S1, 2M2| |relative humidityduringoperation|5 ... 95 %| |**Short-circuit protection**|| |**product function short circuitprotection**|No| |IEC 61508|| |SafetyIntegrityLevel(SIL)accordingto IEC 61508|1| |**ATEX**|| |**certificate of suitability**|| |● accordingto ATEX directive 2014/34/EU|BVS 06 ATEX F001| |● accordingto UKCA|ITS21UKEX0464| |explosion device group and category according to ATEX<br>directive 2014/34/EU|II (2) G, II (2 ) D, I (M2)| |**Galvanic isolation**|| |**(electrically) protective separation according to IEC 60947-1**|All circuits with protective separation (double creepage paths and clearances),<br>the information in the "Protective Separation" test report, No. A0258, must be<br>observed(link see further information)| |**Main circuit**|| |**number ofpoles for main current circuit**|3| |**adjustable current response value current of the current-**<br>**dependent overload release**|2.4 ... 25 A| |**operating voltage**|| |● at AC|| |— at 50 Hz rated value|110 ... 690 V| |— at 60 Hz rated value|110 ... 690 V| Subject to change without notice © Copyright Siemens 3UF71011AA000 Page 2/5 5/29/2026 |**operating frequency rated value**<br>50 ... 60 Hz||| |---|---|---| |**Control circuit/ Control**<br>~~ee~~||| |**type of voltage**<br>AC||| |**Approvals Certificates**<br>~~ee~~||| |**Environment**<br>**General Product Approval**||| |Environmental Con-||| |firmations||| |**General Product Approval**<br>**EMV**|**For use in hazardous locations**|**For use in hazardous locations**| |c<br>ef<br>kK<br>@&|®|®&| |**For use in hazardous locations**<br>**Test Certificates**|**Maritime application**|| |Miscellaneous<br>Special Test Certific-<br>ate<br>Type Test Certific-<br>ates/Test Report<br>&)<br>~~~~~~ ~~~~~~" ~~~~~~|©|| |**Maritime application**<br>**other**||**Industrial Commu-**<br>**nication**| |Confirmation|Confirmation|| |**Further information**<br>~~ee~~||| |**Information on the packaging**||| |https://support.industry.siemens.com/cs/ww/en/view/109813875||| |**Information for data generation and storage**||| |https://support.industry.siemens.com/cs/ww/en/view/109995012||| |**Information- and Downloadcenter (Catalogs, Brochures,…)**||| |https://www.siemens.com/ic10||| |**Industry Mall (Online ordering system)**||| |https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3UF7101-1AA00-0||| |**Cax online generator**||| |https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3UF7101-1AA00-0||| |**Service&Support (Manuals, Certificates, Characteristics, FAQs,...)**||| |https://support.industry.siemens.com/cs/ww/en/ps/3UF7101-1AA00-0||| |**Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)**||| |https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3UF7101-1AA00-0&lang=en||| Subject to change without notice © Copyright Siemens 3UF71011AA000 Page 3/5 5/29/2026 **==> picture [372 x 378] intentionally omitted <==** **----- Start of picture text -----**<br> ,-4-4-4------------------<br>-F<br>SIEMENS<br>|<br>|<br>|<br>|<br>| ray<br>Logic<br>|<br>| SIMOCODE PRO<br>|<br>|<br>|<br>a<br>4/4/2026<br>L1 L2 L3<br>T1 T2 T3<br>**----- End of picture text -----**<br> **last modified:** Subject to change without notice © Copyright Siemens 3UF71011AA000 Page 4/5 5/29/2026 Subject to change without notice © Copyright Siemens 3UF71011AA000 Page 5/5 5/29/2026
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →