Image not available
Illustrative purposes only
3UF7013-1AU00-0
Motor Management System, 4 Inputs, 3 Outputs, 24 VDC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Controller Accessories
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 504.84 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3UF7013-1AU00-0**
**Data sheet**
basic device SIMOCODE pro V EIP, EtherNet/IP, media redundancy, DLR (max. 20 participants) web server, transfer rate 100 Mbps, 2 x bus connection via RJ45, 4 I/3 O freely configurable, Us: 110...240 V AC/DC, input for thermistor connection monostable relay outputs, expandable by expansion modules
|**product brand name**|SIMOCODE|
|---|---|
|**product designation**|Motor management system|
|**design of theproduct**|basic unit 3|
|**product type designation**|pro V EIP|
|**General technical data**||
|**product function**||
|● current measurement|No|
|● voltage measurement|No|
|● activepower measurement|Yes|
|● energymeasurement|No|
|● frequencymeasurement|No|
|● bus communication|Yes|
|● data acquisition function|Yes|
|● diagnostics function|Yes|
|●passwordprotection|Yes|
|● test function|Yes|
|● maintenance function|Yes|
|● MRRT redundancy procedure|No|
|**product component**||
|● input for thermistor connection|Yes|
|● digital input|Yes|
|● input for analogtemperature sensors|No|
|● input forground fault detection|No|
|● relayoutput|Yes|
|**product extension**||
|● temperature monitoringmodule|Yes|
|● current measuringmodule|Yes|
|● current/voltage measuringmodule|Yes|
|● fail-safe digital I/O module|Yes|
|●ground-fault monitoringmodule|Yes|
|● decouplingmodule|Yes|
|● analogI/O module|Yes|
|● digital I/O module with monostable outputs|Yes|
|● digital I/O module with bistable outputs|Yes|
|● control unit with display|Yes|
|● control unit|Yes|
|**apparentpower consumption**|8.3 VA|
|**consumed activepower**|4.8 W|
|insulation voltage with degree of pollution 3 at AC rated value|300 V|
Subject to change without notice © Copyright Siemens
3UF70131AU000 Page 1/8
5/31/2026
|**surge voltage resistance rated value**|4 000 V|
|---|---|
|**shock resistance**||
|**● according to IEC 60068-2-27**|15g/ 11 ms|
|||
|**● vibration resistance**|1 … 6 Hz / 15 mm; 6 … 500 Hz / 2g|
|**switching capacity current of the NO contacts of the relay**<br>**outputs at AC-15**||
|● at 24 V|6 A|
|● at 120 V|6 A|
|● at 230 V|3 A|
|**switching capacity current of the NO contacts of the relay**<br>**outputs at DC-13**||
|● at 24 V|2 A|
|● at 60 V|0.55 A|
|● at 125 V|0.25 A|
|**mechanical service life(operating cycles) typical**|10 000 000|
|electrical endurance(operatingcycles)typical|100 000|
|**buffering time in the event ofpower failure**|0.02 s|
|**reference code according to IEC 81346-2**|F|
|continuous current of the NO contacts of the relayoutputs||
|● at 50 °C|6 A|
|● at 60 °C|5 A|
|**type of input characteristic**|Type 1 in accordance with EN 61131-2|
|**Substance Prohibitance(day/month/year)**|03/01/2017|
|**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1<br>4,4'-isopropylidenediphenol (Bisphenol A, BPA) CAS-No. 80-05-7<br>2-benzyl-2-dimethylamino-4'-morpholinobutyrophenone CAS-No. 119313-12-1|
|**Net Weight**|0.333 kg|
|**Electromagnetic compatibility**||
|EMC emitted interference accordingto IEC 60947-1|class A|
|EMC immunityaccordingto IEC 60947-1|corresponds to degree of severity3|
|**conducted interference**||
|● due to burst accordingto IEC 61000-4-4|2 kV(powerports)/ 1 kV(signalports)|
|● due to conductor-earth surge accordingto IEC 61000-4-5|2 kV|
|● due to conductor-conductor surge according to IEC<br>61000-4-5|1 kV|
|● due to high-frequency radiation according to IEC 61000-<br>4-6|10 V|
|**field-based interference according to IEC 61000-4-3**|10 V/m|
|**electrostatic discharge according to IEC 61000-4-2**|6 kV contact discharge / 8 kV air discharge|
|**conducted HF interference emissions according to**<br>**CISPR11**|corresponds to degree of severity A|
|**field-bound HF interference emission according to CISPR11**|corresponds to degree of severityA|
|**Inputs/ Outputs**||
|**product function**||
|●parameterizable inputs|Yes|
|●parameterizable outputs|Yes|
|**number of inputs**|4|
|● for thermistor connection|1|
|number of digital inputs with a common referencepotential|4|
|**digital input version**||
|● type 1 acc. to IEC 61131|Yes|
|**input voltage at digital input at DC**||
|● rated value|24 V|
|**number of outputs**|3|
|**number of semiconductor outputs**|0|
|**number of outputs as contact-affected switching element**|3|
|**switching behavior**|monostable|
Subject to change without notice © Copyright Siemens
3UF70131AU000 Page 2/8
5/31/2026
||**number of relay outputs**|3||
|---|---|---|---|
||**type of relay outputs**|Monostable||
||**wire length for digital signals maximum**|300 m||
||**wire length for thermistor connection**|||
||● with conductor cross-section = 0.5 mm² maximum|50 m||
||● with conductor cross-section = 1.5 mm² maximum|150 m||
||● with conductor cross-section = 2.5 mm² maximum|250 m||
||**Protective and monitoring functions**|||
||**product function**|||
||● asymmetrydetection|Yes||
||● blockingcurrent evaluation|Yes||
||●power factor monitoring|Yes||
||●ground fault detection|Yes||
||●ground-fault monitoring|No||
||●phase failure detection|Yes||
||●phase sequence recognition|Yes||
||● voltage detection|Yes||
||● monitoringof number of start operations|Yes||
||● overvoltage detection|Yes||
||● overcurrent detection 1phase|Yes||
||● undervoltage detection|Yes||
||● undercurrent detection 1phase|Yes||
||● activepower monitoring|Yes||
||**product function**|||
||● current detection|Yes||
||● overloadprotection|Yes||
||● evaluation of thermistor motorprotection|Yes||
||**total cold resistance number of sensors in series maximum**|1.5 kΩ||
||**response value of thermoresistor**|3 400 ... 3 800 Ω||
||● of the short-circuit control|9 Ω||
||**release value of thermoresistor**|1 500 ... 1 650 Ω||
||**Motor control functions**|||
||**product function**|||
||●parameterizable overload relay|Yes||
||● circuit breaker control|Yes||
||● direct start|Yes||
||● reverse starting|Yes||
||● star-delta circuit|Yes||
||● star-delta reversingcircuit|Yes||
||● Dahlander circuit|Yes||
||● Dahlander reversingcircuit|Yes||
||●pole-changingswitch circuit|Yes||
||●pole-changingswitch reversingcircuit|Yes||
||● slide control|Yes||
||● valve control|Yes||
||**Communication/ Protocol**|||
||**protocol is supported**|||
||● PROFIBUS DPprotocol|No||
||● PROFINET IOprotocol|No||
||● PROFIsafeprotocol|No||
||● Modbus RTU|No||
||● EtherNet/IP|Yes||
||● OPC UA Server|No||
||● LLDP|Yes||
||● Address Resolution Protocol(ARP)|Yes||
||● SNMP|Yes||
||● HTTPS|No||
||● NTP|Yes||
||● Media Redundancy Protocol (MRP)|No||
Subject to change without notice © Copyright Siemens
3UF70131AU000 Page 3/8
5/31/2026
|**product function**||
|---|---|
|● web server|Yes|
|● shared device|No|
|● at the Ethernet interface Autocrossover|Yes|
|● at the Ethernet interface Autonegotiation|Yes|
|● at the Ethernet interface Autosensing|Yes|
|● is supported Device Level Ring (DLR)|Yes|
|● is supported PROFINET system redundancy (S2)|No|
|● supports PROFIenergymeasured values|No|
|● supports PROFIenergyshutdown|No|
|**transfer rate maximum**|100 Mbit/s|
|**identification & maintenance function**||
|● I&M0 - device-specific information|No|
|● I&M1 - higher level designation/location designation|No|
|● I&M2 - installation date|No|
|● I&M3 - comment|No|
|type of electrical connection of the communication interface|2x RJ45|
|**Installation/ mounting/ dimensions**||
|**mounting position**|any|
|**fastening method**|screw and snap-on mounting|
|**height**|111 mm|
|**width**|45 mm|
|**depth**|124 mm|
|**required spacing**||
|● top|40 mm|
|● bottom|40 mm|
|● left|0 mm|
|● right|0 mm|
|**Connections/ Terminals**||
|**product component removable terminal for auxiliary and**<br>**control circuit**|Yes|
|**type of electrical connection**||
|● for auxiliaryand control circuit|screw-type terminals|
|**type of connectable conductor cross-sections**||
|● solid|1x(0.5 ... 4.0mm²), 2x(0.5 ... 2.5 mm²)|
|● finelystranded with core endprocessing|1x(0.5 ... 2.5 mm²), 2x(0.5 ... 1.5 mm²)|
|● for AWG cables solid|1x(20 ... 12), 2x(20 ... 14)|
|● for AWG cables stranded|1x(20 ... 14), 2x(20 ... 16)|
|tighteningtorque with screw-type terminals|0.8 ... 1.2 N·m|
|tighteningtorque [lbf·in] with screw-type terminals|7 ... 10.3 lbf·in|
|**Ambient conditions**||
|installation altitude at height above sea level maximum|2 000 m|
|● note|Restrictions apply to higher installation altitudes, see:<br>https://support.industry.siemens.com/cs/document/109995153|
|**ambient temperature**||
|● duringoperation|-25 ... +60 °C|
|● duringstorage|-40 ... +80 °C|
|● duringtransport|-40 ... +80 °C|
|**environmental category**||
|● during operation according to IEC 60721|3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3<br>(no salt mist), 3S2(sand must notget into the devices), 3M6|
|● during storage according to IEC 60721|1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2<br>(sand must notget into the devices), 1M4|
|● duringtransport accordingto IEC 60721|2K2, 2C1, 2S1, 2M2|
|**relative humidity**||
|● duringoperation|5 ... 95 %|
|**contact rating of auxiliary contacts according to UL**|B300 / R300|
|**Short-circuit protection**||
|design of short-circuit protection per output|Fuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit-<br>breaker C char.: 1.6 A (IEC 60947-5-1) or 6 A (I_K < 500 A)|
Subject to change without notice © Copyright Siemens
3UF70131AU000 Page 4/8
5/31/2026
|Electrical Safety<br>~~a~~|Electrical Safety<br>~~a~~|Electrical Safety<br>~~a~~|
|---|---|---|
|**touch protection against electrical shock**<br>~~a~~||finger-safe<br>~~a~~|
|**ATEX**<br>~~a~~|||
|**certificate of suitability**<br>~~a~~||~~a~~|
|● IECEx||Yes; IECEx BVS 20.0020 / IECEx PTB 18.0004X|
|● accordingto ATEX directive 2014/34/EU||BVS 06 ATEX F001, PTB 18 ATEX 5003 X|
|● acc. to Equipment and Protective System Intended for<br>Use in Potentially Explosive Atmospheres Regulations<br>2016(S.I. 2016 No.1107)||ITS21UKEX0464, ITS21UKEX0455X|
|● accordingto UKCA||ITS21UKEX0464, ITS21UKEX0455X|
|**Galvanic isolation**<br>~~a~~|||
|**(electrically) protective separation according to IEC 60947-1**<br>~~a~~||All circuits with protective separation (double creepage paths and clearances),<br>the information in the "Protective Separation" test report, No. A0258, must be<br>observed(link see further information)<br>~~a~~|
|**design of the electrical isolation**||Protective separation in accordance with IEC 60947-1 for all circuits|
|● note||Test report No. A0258 must be observed<br>(https://support.industry.siemens.com/cs/document/109748152)|
|**Control circuit/ Control**<br>~~a~~|||
|**product function soft starter control**<br>~~a~~||Yes<br>~~a~~|
|**type of voltage of the control supply voltage**||AC/DC|
|**control supply voltage at AC**|||
|● at 50 Hz rated value||110 ... 240 V|
|● at 60 Hz rated value||110 ... 240 V|
|**control supply voltage frequency**|||
|**● 1 rated value**||50 Hz|
|**● 2 rated value**||60 Hz|
|**relative symmetrical tolerance of the control supply voltage**<br>**frequency**||5 %|
|**control supply voltage at DC rated value**||110 ... 240 V|
|**operating range factor control supply voltage rated value at**<br>**DC**|||
|● initial value||0.85|
|● full-scale value||1.1|
|**operating range factor control supply voltage rated value at**<br>**AC at 50 Hz**|||
|● initial value||0.85|
|● full-scale value||1.1|
|**operating range factor control supply voltage rated value at**<br>**AC at 60 Hz**|||
|● initial value||0.85|
|● full-scale value||1.1|
|**inrush currentpeak**|||
|● at 240 V||5 A|
|**duration of inrush currentpeak**|||
|● at 240 V||1 ms|
|**Approvals Certificates**<br>~~a~~|||
|**Environment**<br>~~a~~|**General Product Approval**<br>~~a~~||
**Maritime application**
Subject to change without notice © Copyright Siemens
3UF70131AU000 Page 5/8
5/31/2026
**==> picture [482 x 183] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Miscellaneous|Special Test Certific-|Type Test Certific-|Special Test Certific-|
|ate|ates/Test Report|ate|
|Maritime application|other|
|Confirmation|Miscellaneous|
|wv|reea|SY|ag)lacpass|
|other|
|Confirmation|
**----- End of picture text -----**<br>
**==> picture [510 x 149] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|L|Further information|S|
|Information on the packaging|
|https://support.industry.siemens.com/cs/ww/en/view/109813875|
|Information for data generation and storage|
|https://support.industry.siemens.com/cs/ww/en/view/109995012|
|Information- and Downloadcenter (Catalogs, Brochures,…)|
|https://www.siemens.com/ic10|
|Industry Mall (Online ordering system)|
|https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3UF7013-1AU00-0|
|Cax online generator|
|https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3UF7013-1AU00-0|
|Service&Support (Manuals, Certificates, Characteristics, FAQs,...)|
|https://support.industry.siemens.com/cs/ww/en/ps/3UF7013-1AU00-0|
|Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)|
|https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3UF7013-1AU00-0&lang=en|
**----- End of picture text -----**<br>
Subject to change without notice © Copyright Siemens
3UF70131AU000 Page 6/8
5/31/2026
**==> picture [428 x 256] intentionally omitted <==**
**----- Start of picture text -----**<br>
-F<br>| SIEMENS<br>|<br>|<br>|<br>|<br>|<br>Ek DEVICE FER<br>BUS<br>U GEN. FAULT Logic<br>| NyA : | Port 1Port 2 SIMOCODE PRO F { rag|<br>|<br>|<br>|<br>| + O B A F B A<br>a 8 1 8 1<br>A1 9 10 4 5 8 1 6<br>IN1 IN2 IN3 IN4 24V OUT1/2 OUT3<br>PE OUT1 OUT2 OUT3<br>A2 SPE T1 T2 2 3 7 -Port1:PN -Port2:PN<br>**----- End of picture text -----**<br>
**last modified:**
4/4/2026
Subject to change without notice © Copyright Siemens
3UF70131AU000 Page 7/8
5/31/2026
Subject to change without notice © Copyright Siemens
3UF70131AU000 Page 8/8
5/31/2026
Updated at April 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →