Image not available
Illustrative purposes only
3UF7013-1AB00-0
Motor Management System, 4 Inputs, 3 Outputs, 24 VDC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type:
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 593.34 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3UF7013-1AB00-0** **Data sheet** basic device SIMOCODE pro V EIP, EtherNet/IP, media redundancy, DLR (max. 20 participants) web server, transfer rate 100 Mbps, 2 x bus connection via RJ45, 4 I/3 O freely configurable, Us: 24 V DC, input for thermistor connection monostable relay outputs, expandable by expansion modules |**product brand name**|SIMOCODE| |---|---| |**product designation**|Motor management system| |**design of theproduct**|basic unit 3| |**product type designation**|pro V EIP| |**General technical data**|| |**product function**|| |● current measurement|No| |● voltage measurement|No| |● activepower measurement|Yes| |● energymeasurement|No| |● frequencymeasurement|No| |● bus communication|Yes| |● data acquisition function|Yes| |● diagnostics function|Yes| |●passwordprotection|Yes| |● test function|Yes| |● maintenance function|Yes| |● MRRT redundancy procedure|No| |**product component**|| |● input for thermistor connection|Yes| |● digital input|Yes| |● input for analogtemperature sensors|No| |● input forground fault detection|No| |● relayoutput|Yes| |**product extension**|| |● temperature monitoringmodule|Yes| |● current measuringmodule|Yes| |● current/voltage measuringmodule|Yes| |● fail-safe digital I/O module|Yes| |●ground-fault monitoringmodule|Yes| |● decouplingmodule|Yes| |● analogI/O module|Yes| |● digital I/O module with monostable outputs|Yes| |● digital I/O module with bistable outputs|Yes| |● control unit with display|Yes| |● control unit|Yes| |**consumed activepower**|3.9 W| |insulation voltage with degree ofpollution 3 at AC rated value|300 V| |**surge voltage resistance rated value**|4 000 V| Subject to change without notice © Copyright Siemens 3UF70131AB000 Page 1/7 6/2/2026 ||**shock resistance**||| |---|---|---|---| ||**● according to IEC 60068-2-27**|15g/ 11 ms|| ||||| ||**● vibration resistance**|1 … 6 Hz / 15 mm; 6 … 500 Hz / 2g|| ||**switching capacity current of the NO contacts of the relay**<br>**outputs at AC-15**||| ||● at 24 V|6 A|| ||● at 120 V|6 A|| ||● at 230 V|3 A|| ||**switching capacity current of the NO contacts of the relay**<br>**outputs at DC-13**||| ||● at 24 V|2 A|| ||● at 60 V|0.55 A|| ||● at 125 V|0.25 A|| ||**mechanical service life(operating cycles) typical**|10 000 000|| ||electrical endurance(operatingcycles)typical|100 000|| ||**buffering time in the event ofpower failure**|0.02 s|| ||**reference code according to IEC 81346-2**|F|| ||continuous current of the NO contacts of the relayoutputs||| ||● at 50 °C|6 A|| ||● at 60 °C|5 A|| ||**type of input characteristic**|Type 1 in accordance with EN 61131-2|| ||**Substance Prohibitance(day/month/year)**|03/01/2017|| ||**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1<br>4,4'-isopropylidenediphenol(Bisphenol A, BPA)CAS-No. 80-05-7|| ||**Net Weight**|0.32 kg|| ||**Electromagnetic compatibility**||| ||EMC emitted interference accordingto IEC 60947-1|class A|| ||EMC immunityaccordingto IEC 60947-1|corresponds to degree of severity3|| ||**conducted interference**||| ||● due to burst accordingto IEC 61000-4-4|2 kV(powerports)/ 1 kV(signalports)|| ||● due to conductor-earth surge accordingto IEC 61000-4-5|2 kV|| ||● due to conductor-conductor surge according to IEC<br>61000-4-5|1 kV|| ||● due to high-frequency radiation according to IEC 61000-<br>4-6|10 V|| ||**field-based interference according to IEC 61000-4-3**|10 V/m|| ||**electrostatic discharge according to IEC 61000-4-2**|6 kV contact discharge / 8 kV air discharge|| ||**conducted HF interference emissions according to**<br>**CISPR11**|corresponds to degree of severity A|| ||**field-bound HF interference emission according to CISPR11**|corresponds to degree of severityA|| ||**Inputs/ Outputs**||| ||**product function**||| ||●parameterizable inputs|Yes|| ||●parameterizable outputs|Yes|| ||**number of inputs**|4|| ||● for thermistor connection|1|| ||number of digital inputs with a common referencepotential|4|| ||**digital input version**||| ||● type 1 acc. to IEC 61131|Yes|| ||**input voltage at digital input at DC**||| ||● rated value|24 V|| ||**number of outputs**|3|| ||**number of semiconductor outputs**|0|| ||**number of outputs as contact-affected switching element**|3|| ||**switching behavior**|monostable|| ||**number of relay outputs**|3|| ||**type of relay outputs**|Monostable|| Subject to change without notice © Copyright Siemens 3UF70131AB000 Page 2/7 6/2/2026 ||**wire length for digital signals maximum**|300 m|| |---|---|---|---| ||**wire length for thermistor connection**||| ||● with conductor cross-section = 0.5 mm² maximum|50 m|| ||● with conductor cross-section = 1.5 mm² maximum|150 m|| ||● with conductor cross-section = 2.5 mm² maximum|250 m|| ||**Protective and monitoring functions**||| ||**product function**||| ||● asymmetrydetection|Yes|| ||● blockingcurrent evaluation|Yes|| ||●power factor monitoring|Yes|| ||●ground fault detection|Yes|| ||●ground-fault monitoring|No|| ||●phase failure detection|Yes|| ||●phase sequence recognition|Yes|| ||● voltage detection|Yes|| ||● monitoringof number of start operations|Yes|| ||● overvoltage detection|Yes|| ||● overcurrent detection 1phase|Yes|| ||● undervoltage detection|Yes|| ||● undercurrent detection 1phase|Yes|| ||● activepower monitoring|Yes|| ||**product function**||| ||● current detection|Yes|| ||● overloadprotection|Yes|| ||● evaluation of thermistor motorprotection|Yes|| ||**total cold resistance number of sensors in series maximum**|1.5 kΩ|| ||**response value of thermoresistor**|3 400 ... 3 800 Ω|| ||● of the short-circuit control|9 Ω|| ||**release value of thermoresistor**|1 500 ... 1 650 Ω|| ||**Motor control functions**||| ||**product function**||| ||●parameterizable overload relay|Yes|| ||● circuit breaker control|Yes|| ||● direct start|Yes|| ||● reverse starting|Yes|| ||● star-delta circuit|Yes|| ||● star-delta reversingcircuit|Yes|| ||● Dahlander circuit|Yes|| ||● Dahlander reversingcircuit|Yes|| ||●pole-changingswitch circuit|Yes|| ||●pole-changingswitch reversingcircuit|Yes|| ||● slide control|Yes|| ||● valve control|Yes|| ||**Communication/ Protocol**||| ||**protocol is supported**||| ||● PROFIBUS DPprotocol|No|| ||● PROFINET IOprotocol|No|| ||● PROFIsafeprotocol|No|| ||● Modbus RTU|No|| ||● EtherNet/IP|Yes|| ||● OPC UA Server|No|| ||● LLDP|Yes|| ||● Address Resolution Protocol(ARP)|Yes|| ||● SNMP|Yes|| ||● HTTPS|No|| ||● NTP|Yes|| ||● Media RedundancyProtocol(MRP)|No|| ||**product function**||| ||● web server|Yes|| Subject to change without notice © Copyright Siemens 3UF70131AB000 Page 3/7 6/2/2026 |● shared device|No| |---|---| |● at the Ethernet interface Autocrossover|Yes| |● at the Ethernet interface Autonegotiation|Yes| |● at the Ethernet interface Autosensing|Yes| |● is supported Device Level Ring (DLR)|Yes| |● is supported PROFINET system redundancy (S2)|No| |● supports PROFIenergymeasured values|No| |● supports PROFIenergyshutdown|No| |**transfer rate maximum**|100 Mbit/s| |**identification & maintenance function**|| |● I&M0 - device-specific information|No| |● I&M1 - higher level designation/location designation|No| |● I&M2 - installation date|No| |● I&M3 - comment|No| |type of electrical connection of the communication interface|2x RJ45| |**Installation/ mounting/ dimensions**|| |**mounting position**|any| |**fastening method**|screw and snap-on mounting| |**height**|111 mm| |**width**|45 mm| |**depth**|124 mm| |**required spacing**|| |● top|40 mm| |● bottom|40 mm| |● left|0 mm| |● right|0 mm| |**Connections/ Terminals**|| |**product component removable terminal for auxiliary and**<br>**control circuit**|Yes| |**type of electrical connection**|| |● for auxiliaryand control circuit|screw-type terminals| |**type of connectable conductor cross-sections**|| |● solid|1x(0.5 ... 4.0mm²), 2x(0.5 ... 2.5 mm²)| |● finelystranded with core endprocessing|1x(0.5 ... 2.5 mm²), 2x(0.5 ... 1.5 mm²)| |● for AWG cables solid|1x(20 ... 12), 2x(20 ... 14)| |● for AWG cables stranded|1x(20 ... 14), 2x(20 ... 16)| |tighteningtorque with screw-type terminals|0.8 ... 1.2 N·m| |tighteningtorque [lbf·in] with screw-type terminals|7 ... 10.3 lbf·in| |**Ambient conditions**|| |installation altitude at height above sea level maximum|2 000 m| |● note|Restrictions apply to higher installation altitudes, see:<br>https://support.industry.siemens.com/cs/document/109995153| |**ambient temperature**|| |● duringoperation|-25 ... +60 °C| |● duringstorage|-40 ... +80 °C| |● duringtransport|-40 ... +80 °C| |**environmental category**|| |● during operation according to IEC 60721|3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3<br>(no salt mist), 3S2(sand must notget into the devices), 3M6| |● during storage according to IEC 60721|1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2<br>(sand must notget into the devices), 1M4| |● duringtransport accordingto IEC 60721|2K2, 2C1, 2S1, 2M2| |**relative humidity**|| |● duringoperation|5 ... 95 %| |**contact rating of auxiliary contacts according to UL**|B300 / R300| |**Short-circuit protection**|| |design of short-circuit protection per output|Fuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit-<br>breaker C char.: 1.6 A(IEC 60947-5-1)or 6 A(I_K < 500 A)| |Electrical Safety|| |**touch protection against electrical shock**|finger-safe| Subject to change without notice © Copyright Siemens 3UF70131AB000 Page 4/7 6/2/2026 |**ATEX**<br>~~SS~~|**ATEX**<br>~~SS~~|**ATEX**<br>~~SS~~|**ATEX**<br>~~SS~~|**ATEX**<br>~~SS~~| |---|---|---|---|---| |**certificate of suitability**||||| |● IECEx||Yes; IECEx BVS 20.0020 / IECEx PTB 18.0004X||| |● accordingto ATEX directive 2014/34/EU||BVS 06 ATEX F001, PTB 18 ATEX 5003 X|BVS 06 ATEX F001, PTB 18 ATEX 5003 X|| |● acc. to Equipment and Protective System Intended for||ITS21UKEX0464, ITS21UKEX0455X||| |Use in Potentially Explosive Atmospheres Regulations||||| |2016(S.I. 2016 No.1107)||||| |● accordingto UKCA||ITS21UKEX0464, ITS21UKEX0455X||| |**Galvanic isolation**<br>~~Pn~~||||| |**(electrically) protective separation according to IEC 60947-1**||All circuits with protective separation (double creepage paths and clearances),||| |||the information in the "Protective Separation" test report, No. A0258, must be||| |||observed(link see further information)||| |**design of the electrical isolation**||Protective separation in accordance with IEC 60947-1 for all circuits|aration in accordance with IEC 60947-1 for all circuits|| |● note||Test report No. A0258 must be observed|Test report No. A0258 must be observed|| |||(https://support.industry.siemens.com/cs/document/109748152)||| |**Control circuit/ Control**<br>~~ES~~||||| |**product function soft starter control**||Yes||| |**type of voltage of the control supply voltage**||DC||| |**control supply voltage at DC rated value**||24 V||| |**control supply voltage 1 at DC rated value**||24 V||| |**operating range factor control supply voltage rated value at**|**operating range factor control supply voltage rated value at**|||| |**DC**||||| |● initial value||0.85||| |● full-scale value||1.2||| |**inrush currentpeak**||||| |● at 24 V||17 A||| |**duration of inrush currentpeak**||||| |● at 24 V||1.1 ms||| |**Approvals Certificates**<br>~~ES~~||||| |**Environment**|**General Product Approval**|||| |Environmental Con-||||| |firmations||||| |**General Product Ap-**<br>**proval**<br>**EMV**||**For use in hazardous locations**||| |||||| |**For use in hazardous locations**|**Test Certificates**|||**Maritime application**| |Miscellaneous<br>=|Special Test Certific-<br>ate<br>Type Test Certific-<br>ates/Test Report<br>Special Test Certific-<br>ate<br>~~Ss~~Cr?|||| |**Maritime application**<br>**other**<br>Confirmation<br>Miscellaneous<br>~~=e—~~||||| |**other**||||| Subject to change without notice © Copyright Siemens 3UF70131AB000 Page 5/7 6/2/2026 Confirmation **Further information Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3UF7013-1AB00-0 **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3UF7013-1AB00-0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3UF7013-1AB00-0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3UF7013-1AB00-0&lang=en **==> picture [203 x 225] intentionally omitted <==** Subject to change without notice © Copyright Siemens 3UF70131AB000 Page 6/7 6/2/2026 **==> picture [428 x 255] intentionally omitted <==** **----- Start of picture text -----**<br> -F SIEMENS |<br>| |<br>FR op DEVICE FR<br>BUS<br>U GEN. FAULT Logic |<br>l | |: | |<br>Port 1 SIMOCODE PRO<br>‘ Sy [a Port 2 ima<br>|<br>|<br>|<br>|£ B A B A<br>i 8 1 8 1<br>A1 9 10 4 5 8 1 6<br>IN1 IN2 IN3 IN4 24V OUT1/2 OUT3<br>PE OUT1 OUT2 OUT3<br>A2 SPE T1 T2 2 3 7 -Port1:PN -Port2:PN<br>**----- End of picture text -----**<br> **last modified:** 4/4/2026 Subject to change without notice © Copyright Siemens 3UF70131AB000 Page 7/7 6/2/2026
Updated at March 31, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →