Image not available
Illustrative purposes only
3UF7011-1AU00-1
Motor Management System, 4 Inputs, 3 Outputs, 24 VDC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Controller Accessories
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 473.28 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3UF7011-1AU00-1**
**Data sheet**
basic device SIMOCODE pro V PN GP , Ethernet/PROFINET IO, PN system redundancy, OPC UA server, web server, transfer rate 100 Mbps, 2 x bus connection via RJ45, 4 I/3 O freely configurable, Us: 110...240 V AC/DC, input for thermistor connection monostable relay outputs, expandable by 1 expansion module(DM, TM, EM)
|**product brand name**|SIMOCODE|
|---|---|
|**product designation**|Motor management system|
|**design of theproduct**|basic unit 3|
|**product type designation**|pro V PN GP|
|**General technical data**||
|**product function**||
|● current measurement|No|
|● voltage measurement|No|
|● activepower measurement|No|
|● energymeasurement|No|
|● frequencymeasurement|No|
|● bus communication|Yes|
|● data acquisition function|Yes|
|● diagnostics function|Yes|
|●passwordprotection|Yes|
|● test function|Yes|
|● maintenance function|Yes|
|**product component**||
|● input for thermistor connection|Yes|
|● digital input|Yes|
|● input for analogtemperature sensors|No|
|● input forground fault detection|No|
|● relayoutput|Yes|
|**product extension**||
|● temperature monitoringmodule|Yes|
|● current measuringmodule|Yes|
|● current/voltage measuringmodule|No|
|● fail-safe digital I/O module|No|
|●ground-fault monitoringmodule|Yes|
|● decouplingmodule|No|
|● analogI/O module|No|
|● digital I/O module with monostable outputs|Yes|
|● digital I/O module with bistable outputs|No|
|● control unit with display|No|
|● control unit|Yes|
|**apparentpower consumption**|8.3 VA|
|**consumed activepower**|4.5 W|
|insulation voltage with degree ofpollution 3 at AC rated value|300 V|
|**surge voltage resistance rated value**|4 000 V|
Subject to change without notice © Copyright Siemens
3UF70111AU001 Page 1/8
6/1/2026
||**shock resistance**|||
|---|---|---|---|
||**● according to IEC 60068-2-27**|15g/ 11 ms||
|||||
||**● vibration resistance**|1 … 6 Hz / 15 mm; 6 … 500 Hz / 2g||
||**switching capacity current of the NO contacts of the relay**<br>**outputs at AC-15**|||
||● at 24 V|6 A||
||● at 120 V|6 A||
||● at 230 V|3 A||
||**switching capacity current of the NO contacts of the relay**<br>**outputs at DC-13**|||
||● at 24 V|2 A||
||● at 60 V|0.55 A||
||● at 125 V|0.25 A||
||**mechanical service life(operating cycles) typical**|10 000 000||
||electrical endurance(operatingcycles)typical|100 000||
||**buffering time in the event ofpower failure**|0.02 s||
||**reference code according to IEC 81346-2**|F||
||continuous current of the NO contacts of the relayoutputs|||
||● at 50 °C|6 A||
||● at 60 °C|5 A||
||**type of input characteristic**|Type 1 in accordance with EN 61131-2||
||**Substance Prohibitance(day/month/year)**|08/31/2018||
||**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>4,4'-isopropylidenediphenol (Bisphenol A, BPA) CAS-No. 80-05-7<br>2-benzyl-2-dimethylamino-4'-morpholinobutyrophenone CAS-No. 119313-12-1||
||**Net Weight**|0.335 kg||
||**Electromagnetic compatibility**|||
||EMC emitted interference accordingto IEC 60947-1|class A||
||EMC immunityaccordingto IEC 60947-1|corresponds to degree of severity3||
||**conducted interference**|||
||● due to burst accordingto IEC 61000-4-4|2 kV(powerports)/ 1 kV(signalports)||
||● due to conductor-earth surge accordingto IEC 61000-4-5|2 kV||
||● due to conductor-conductor surge according to IEC<br>61000-4-5|1 kV||
||● due to high-frequency radiation according to IEC 61000-<br>4-6|10 V||
||**field-based interference according to IEC 61000-4-3**|10 V/m||
||**electrostatic discharge according to IEC 61000-4-2**|6 kV contact discharge / 8 kV air discharge||
||**conducted HF interference emissions according to**<br>**CISPR11**|corresponds to degree of severity A||
||**field-bound HF interference emission according to CISPR11**|corresponds to degree of severityA||
||**Inputs/ Outputs**|||
||**product function**|||
||●parameterizable inputs|Yes||
||●parameterizable outputs|Yes||
||**number of inputs**|4||
||● for thermistor connection|1||
||number of digital inputs with a common referencepotential|4||
||**digital input version**|||
||● type 1 acc. to IEC 61131|Yes||
||**input voltage at digital input at DC**|||
||● rated value|24 V||
||**number of outputs**|3||
||**number of semiconductor outputs**|0||
||**number of outputs as contact-affected switching element**|3||
||**switching behavior**|monostable||
||**number of relay outputs**|3||
||**type of relay outputs**|Monostable||
Subject to change without notice © Copyright Siemens
3UF70111AU001 Page 2/8
6/1/2026
||**wire length for digital signals maximum**|300 m||
|---|---|---|---|
||**wire length for thermistor connection**|||
||● with conductor cross-section = 0.5 mm² maximum|50 m||
||● with conductor cross-section = 1.5 mm² maximum|150 m||
||● with conductor cross-section = 2.5 mm² maximum|250 m||
||**Protective and monitoring functions**|||
||**product function**|||
||● asymmetrydetection|Yes||
||● blockingcurrent evaluation|Yes||
||●power factor monitoring|No||
||●ground fault detection|Yes||
||●ground-fault monitoring|No||
||●phase failure detection|Yes||
||●phase sequence recognition|No||
||● voltage detection|No||
||● monitoringof number of start operations|Yes||
||● overvoltage detection|No||
||● overcurrent detection 1phase|Yes||
||● undervoltage detection|No||
||● undercurrent detection 1phase|Yes||
||● activepower monitoring|No||
||**product function**|||
||● current detection|Yes||
||● overloadprotection|Yes||
||● evaluation of thermistor motorprotection|Yes||
||**total cold resistance number of sensors in series maximum**|1.5 kΩ||
||**response value of thermoresistor**|3 400 ... 3 800 Ω||
||● of the short-circuit control|9 Ω||
||**release value of thermoresistor**|1 500 ... 1 650 Ω||
||**Motor control functions**|||
||**product function**|||
||●parameterizable overload relay|Yes||
||● circuit breaker control|Yes||
||● direct start|Yes||
||● reverse starting|Yes||
||● star-delta circuit|Yes||
||● star-delta reversingcircuit|No||
||● Dahlander circuit|No||
||● Dahlander reversingcircuit|No||
||●pole-changingswitch circuit|No||
||●pole-changingswitch reversingcircuit|No||
||● slide control|No||
||● valve control|No||
||**Communication/ Protocol**|||
||**protocol is supported**|||
||● PROFIBUS DPprotocol|No||
||● PROFINET IOprotocol|Yes||
||● PROFIsafeprotocol|No||
||● Modbus RTU|No||
||● EtherNet/IP|No||
||● OPC UA Server|Yes||
||● LLDP|Yes||
||● Address Resolution Protocol(ARP)|Yes||
||● SNMP|Yes||
||● HTTPS|Yes||
||● NTP|Yes||
||● Media RedundancyProtocol(MRP)|Yes||
||**product function**|||
||● web server|Yes||
Subject to change without notice © Copyright Siemens
3UF70111AU001 Page 3/8
6/1/2026
|● shared device|No|
|---|---|
|● at the Ethernet interface Autocrossover|Yes|
|● at the Ethernet interface Autonegotiation|Yes|
|● at the Ethernet interface Autosensing|Yes|
|● Media Redundancy Protocol for Planned Duplication<br>(MRPD)|Yes|
|● is supported Device Level Ring (DLR)|No|
|● is supported PROFINET system redundancy (S2)|Yes|
|● supports PROFIenergymeasured values|Yes|
|● supports PROFIenergyshutdown|Yes|
|**transfer rate**|100 Mbit/s|
|**transfer rate maximum**|100 Mbit/s|
|**PROFINET conformity class**|C|
|**identification & maintenance function**||
|● I&M0 - device-specific information|Yes|
|● I&M1 - higher level designation/location designation|Yes|
|● I&M2 - installation date|Yes|
|● I&M3 - comment|Yes|
|type of electrical connection of the communication interface|2x RJ45|
|**Installation/ mounting/ dimensions**||
|**mounting position**|any|
|**fastening method**|screw and snap-on mounting|
|**height**|111 mm|
|**width**|45 mm|
|**depth**|124 mm|
|**required spacing**||
|● top|40 mm|
|● bottom|40 mm|
|● left|0 mm|
|● right|0 mm|
|**Connections/ Terminals**||
|**product component removable terminal for auxiliary and**<br>**control circuit**|Yes|
|**type of electrical connection**||
|● for auxiliaryand control circuit|screw-type terminals|
|**type of connectable conductor cross-sections**||
|● solid|1x(0.5 ... 4.0mm²), 2x(0.5 ... 2.5 mm²)|
|● finelystranded with core endprocessing|1x(0.5 ... 2.5 mm²), 2x(0.5 ... 1.5 mm²)|
|● for AWG cables solid|1x(20 ... 12), 2x(20 ... 14)|
|● for AWG cables stranded|1x(20 ... 14), 2x(20 ... 16)|
|tighteningtorque with screw-type terminals|0.8 ... 1.2 N·m|
|tighteningtorque [lbf·in] with screw-type terminals|7 ... 10.3 lbf·in|
|**Ambient conditions**||
|installation altitude at height above sea level maximum|2 000 m|
|● note|Restrictions apply to higher installation altitudes, see:<br>https://support.industry.siemens.com/cs/document/109995153|
|**ambient temperature**||
|● duringoperation|-25 ... +60 °C|
|● duringstorage|-40 ... +80 °C|
|● duringtransport|-40 ... +80 °C|
|**environmental category**||
|● during operation according to IEC 60721|3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3<br>(no salt mist), 3S2(sand must notget into the devices), 3M6|
|● during storage according to IEC 60721|1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2<br>(sand must notget into the devices), 1M4|
|● duringtransport accordingto IEC 60721|2K2, 2C1, 2S1, 2M2|
|**relative humidity**||
|● duringoperation|5 ... 95 %|
|**contact rating of auxiliary contacts according to UL**|B300 / R300|
|**Short-circuit protection**||
Subject to change without notice © Copyright Siemens
3UF70111AU001 Page 4/8
6/1/2026
|design of short-circuit protection per output<br>~~OO~~|design of short-circuit protection per output<br>~~OO~~|Fuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit-<br>breaker C char.: 1.6 A(IEC 60947-5-1)or 6 A(I_K < 500 A)<br>~~—————OOmO—O—O—O—O—E—O—O—OEOEEE~~|
|---|---|---|
|Electrical Safety<br>~~OO~~<br>~~—————OOmO—O—O—O—O—E—O—O—OEOEEE~~|||
|**touch protection against electrical shock**<br>~~OO~~||finger-safe<br>~~—————OOmO—O—O—O—O—E—O—O—OEOEEE~~|
|**ATEX**<br>~~|~~|||
|**certificate of suitability**<br>~~|~~||~~|~~|
|● IECEx||Yes; IECEx BVS 20.0020|
|● accordingto ATEX directive 2014/34/EU||BVS 06 ATEX F001|
|● accordingto UKCA||ITS21UKEX0464|
|**Galvanic isolation**<br>~~|~~|||
|**(electrically) protective separation according to IEC 60947-1**<br>~~|~~||All circuits with protective separation (double creepage paths and clearances),<br>the information in the "Protective Separation" test report, No. A0258, must be<br>observed(link see further information)<br>~~|~~|
|**design of the electrical isolation**||Protective separation in accordance with IEC 60947-1 for all circuits|
|● note||Test report No. A0258 must be observed<br>(https://support.industry.siemens.com/cs/document/109748152)|
|**Control circuit/ Control**<br>~~|~~|||
|**product function soft starter control**<br>~~|~~||Yes<br>~~|~~|
|**type of voltage of the control supply voltage**||AC/DC|
|**control supply voltage at AC**|||
|● at 50 Hz rated value||110 ... 240 V|
|● at 60 Hz rated value||110 ... 240 V|
|**control supply voltage frequency**|||
|**● 1 rated value**||50 Hz|
|**● 2 rated value**||60 Hz|
|**relative symmetrical tolerance of the control supply voltage**<br>**frequency**||5 %|
|**control supply voltage at DC rated value**||110 ... 240 V|
|**operating range factor control supply voltage rated value at**<br>**DC**|||
|● initial value||0.85|
|● full-scale value||1.1|
|**operating range factor control supply voltage rated value at**<br>**AC at 50 Hz**|||
|● initial value||0.85|
|● full-scale value||1.1|
|**operating range factor control supply voltage rated value at**<br>**AC at 60 Hz**|||
|● initial value||0.85|
|● full-scale value||1.1|
|**inrush currentpeak**|||
|● at 240 V||15 A|
|**duration of inrush currentpeak**|||
|● at 240 V||1 ms|
|**Approvals Certificates**<br>~~ee~~|||
|**Environment**<br>~~ee~~|**General Product Approval**<br>~~ee~~||
**General Product Approval**
**For use in hazardous locations**
**Test Certificates**
Subject to change without notice © Copyright Siemens
3UF70111AU001 Page 5/8
6/1/2026
Miscellaneous Special Test CertificType Test CertificSpecial Test Certificate ates/Test Report ate €x) ~~OO TT~~ **Maritime application other** oe & Toys@ © Rae)iéKE ~~——~~ Confirmation **other Industrial Communication** Confirmation PROFINET ~~E~~ **Further information** ~~S~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3UF7011-1AU00-1 **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3UF7011-1AU00-1 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3UF7011-1AU00-1 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3UF7011-1AU00-1&lang=en
Subject to change without notice © Copyright Siemens
3UF70111AU001 Page 6/8
6/1/2026
**==> picture [428 x 256] intentionally omitted <==**
**----- Start of picture text -----**<br>
-F<br>| SIEMENS<br>|<br>|<br>|<br>|<br>|<br>ER 1, DEVICE at<br>BUS<br>U GEN. FAULT Logic<br>| Syr :f|e Port 1Port 2 SIMOCODE PRO i { wy|<br>|<br>|i B A B A |<br>i 8 1 8 1<br>A1 9 10 4 5 8 1 6<br>IN1 IN2 IN3 IN4 24V OUT1/2 OUT3<br>PE OUT1 OUT2 OUT3<br>A2 SPE T1 T2 2 3 7 -Port1:PN -Port2:PN<br>**----- End of picture text -----**<br>
**last modified:**
4/4/2026
Subject to change without notice © Copyright Siemens
3UF70111AU001 Page 7/8
6/1/2026
Subject to change without notice © Copyright Siemens
3UF70111AU001 Page 8/8
6/1/2026
Updated at April 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →