Image not available
Illustrative purposes only
3UF7000-1AB00-0
Motor Management System, 4 Inputs, 3 Outputs, 24 VDC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type:
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 420.21 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3UF7000-1AB00-0** **Data sheet** basic device SIMOCODE pro C, PROFIBUS DP interface 12 Mbps, RS-485, 4 I/3 O freely configurable, Us: 24 V DC, input for thermistor connection monostable relay outputs |Ga 63 3 cmeh<br>o<br>OoGarearey Ces|basic device SIMOCODE pro C, PROFIBUS DP interface 12 Mbps, RS-485, 4 I/3<br>O freely configurable, Us: 24 V DC, input for thermistor connection monostable<br>relay outputs| |---|---| |**product brand name**|SIMOCODE| |**product designation**|Motor management system| |**design of theproduct**|basic unit 1| |**product type designation**|pro C| |**General technical data**|| |**certificate of suitability**|CE / UL / CSA / CCC / C-Tick (RCM) / GOST / NOM / ATEX / NEPSI / ABS /<br>DNV / GL / LRS / RoHS| |**product function**|| |● current measurement|No| |● voltage measurement|No| |● activepower measurement|No| |● energymeasurement|No| |● frequencymeasurement|No| |● bus communication|Yes| |● data acquisition function|Yes| |● diagnostics function|Yes| |●passwordprotection|Yes| |● test function|Yes| |● maintenance function|Yes| |● MRRT redundancy procedure|No| |**product component**|| |● input for thermistor connection|Yes| |● digital input|Yes| |● input for analogtemperature sensors|No| |● input forground fault detection|No| |● relayoutput|Yes| |**product extension**|| |● temperature monitoringmodule|No| |● current measuringmodule|Yes| |● current/voltage measuringmodule|No| |● fail-safe digital I/O module|No| |●ground-fault monitoringmodule|No| |● decouplingmodule|No| |● analogI/O module|No| |● digital I/O module with monostable outputs|No| |● digital I/O module with bistable outputs|No| |● control unit with display|No| |● control unit|Yes| |**consumed active power**|2.3 W| Subject to change without notice © Copyright Siemens 3UF70001AB000 Page 1/7 6/4/2026 |insulation voltage with degree ofpollution 3 at AC rated value|300 V| |---|---| |**surge voltage resistance rated value**|4 000 V| |**shock resistance**|| |**● according to IEC 60068-2-27**|15g/ 11 ms| ||| |**● vibration resistance**|1 … 6 Hz / 15 mm; 6 … 500 Hz / 2g| |**switching capacity current of the NO contacts of the relay**<br>**outputs at AC-15**|| |● at 24 V|6 A| |● at 120 V|6 A| |● at 230 V|3 A| |**switching capacity current of the NO contacts of the relay**<br>**outputs at DC-13**|| |● at 24 V|2 A| |● at 60 V|0.55 A| |● at 125 V|0.25 A| |**mechanical service life(operating cycles) typical**|10 000 000| |electrical endurance(operatingcycles)typical|100 000| |**buffering time in the event ofpower failure**|0.05 s| |**reference code according to IEC 81346-2**|F| |continuous current of the NO contacts of the relayoutputs|| |● at 50 °C|6 A| |● at 60 °C|5 A| |**type of input characteristic**|Type 1 in accordance with EN 61131-2| |**Substance Prohibitance(day/month/year)**|05/01/2012| |**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1| |**Net Weight**|0.295g| |**Electromagnetic compatibility**|| |EMC emitted interference accordingto IEC 60947-1|class A| |EMC immunityaccordingto IEC 60947-1|corresponds to degree of severity3| |**conducted interference**|| |● due to burst accordingto IEC 61000-4-4|2 kV(powerports)/ 1 kV(signalports)| |● due to conductor-earth surge accordingto IEC 61000-4-5|2 kV| |● due to conductor-conductor surge according to IEC<br>61000-4-5|1 kV| |● due to high-frequency radiation according to IEC 61000-<br>4-6|10 V| |**field-based interference according to IEC 61000-4-3**|10 V/m| |**electrostatic discharge according to IEC 61000-4-2**|6 kV contact discharge / 8 kV air discharge| |**conducted HF interference emissions according to**<br>**CISPR11**|corresponds to degree of severity A| |**field-bound HF interference emission according to CISPR11**|corresponds to degree of severityA| |**Inputs/ Outputs**|| |**product function**|| |●parameterizable inputs|Yes| |●parameterizable outputs|Yes| |**number of inputs**|4| |● for thermistor connection|1| |number of digital inputs with a common referencepotential|4| |**digital input version**|| |● type 1 acc. to IEC 61131|Yes| |**input voltage at digital input at DC**|| |● rated value|24 V| |**number of outputs**|3| |**number of semiconductor outputs**|0| |**number of outputs as contact-affected switching element**|3| |**switching behavior**|monostable| Subject to change without notice © Copyright Siemens 3UF70001AB000 Page 2/7 6/4/2026 ||**number of relay outputs**|3|| |---|---|---|---| ||**type of relay outputs**|Monostable|| ||**wire length for digital signals maximum**|300 m|| ||**wire length for thermistor connection**||| ||● with conductor cross-section = 0.5 mm² maximum|50 m|| ||● with conductor cross-section = 1.5 mm² maximum|150 m|| ||● with conductor cross-section = 2.5 mm² maximum|250 m|| ||**Protective and monitoring functions**||| ||**product function**||| ||● asymmetrydetection|Yes|| ||● blockingcurrent evaluation|Yes|| ||●power factor monitoring|No|| ||●ground fault detection|Yes|| ||●ground-fault monitoring|No|| ||●phase failure detection|Yes|| ||●phase sequence recognition|No|| ||● voltage detection|No|| ||● monitoringof number of start operations|Yes|| ||● overvoltage detection|No|| ||● overcurrent detection 1phase|Yes|| ||● undervoltage detection|No|| ||● undercurrent detection 1phase|Yes|| ||● activepower monitoring|No|| ||**product function**||| ||● current detection|Yes|| ||● overloadprotection|Yes|| ||● evaluation of thermistor motorprotection|Yes|| ||**total cold resistance number of sensors in series maximum**|1.5 kΩ|| ||**response value of thermoresistor**|3 400 ... 3 800 Ω|| ||● of the short-circuit control|9 Ω|| ||**release value of thermoresistor**|1 500 ... 1 650 Ω|| ||**Motor control functions**||| ||**product function**||| ||●parameterizable overload relay|Yes|| ||● circuit breaker control|Yes|| ||● direct start|Yes|| ||● reverse starting|Yes|| ||● star-delta circuit|No|| ||● star-delta reversingcircuit|No|| ||● Dahlander circuit|No|| ||● Dahlander reversingcircuit|No|| ||●pole-changingswitch circuit|No|| ||●pole-changingswitch reversingcircuit|No|| ||● slide control|No|| ||● valve control|No|| ||**Communication/ Protocol**||| ||**protocol is supported**||| ||● PROFIBUS DPprotocol|Yes|| ||● PROFINET IOprotocol|No|| ||● PROFIsafeprotocol|No|| ||● Modbus RTU|No|| ||● EtherNet/IP|No|| ||● OPC UA Server|No|| ||● LLDP|No|| ||● Address Resolution Protocol(ARP)|No|| ||● SNMP|No|| ||● HTTPS|No|| ||● NTP|No|| ||● Media Redundancy Protocol (MRP)|No|| Subject to change without notice © Copyright Siemens 3UF70001AB000 Page 3/7 6/4/2026 |**product function**|| |---|---| |● web server|No| |● shared device|No| |● at the Ethernet interface Autocrossover|No| |● at the Ethernet interface Autonegotiation|No| |● at the Ethernet interface Autosensing|No| |● is supported Device Level Ring (DLR)|No| |● is supported PROFINET system redundancy (S2)|No| |● supports PROFIenergymeasured values|No| |● supports PROFIenergyshutdown|No| |**transfer rate maximum**|12 Mbit/s| |**identification & maintenance function**|| |● I&M0 - device-specific information|Yes| |● I&M1 - higher level designation/location designation|Yes| |● I&M2 - installation date|Yes| |● I&M3 - comment|Yes| |type of electrical connection of the communication interface|9-pin SUB-D socket(12 Mbit)/ screw terminal(1.5 Mbit)| |**Installation/ mounting/ dimensions**|| |**mounting position**|any| |**fastening method**|screw and snap-on mounting| |**height**|111 mm| |**width**|45 mm| |**depth**|95 mm| |**required spacing**|| |● top|40 mm| |● bottom|40 mm| |● left|0 mm| |● right|0 mm| |**Connections/ Terminals**|| |**product component removable terminal for auxiliary and**<br>**control circuit**|Yes| |**type of electrical connection**|| |● for auxiliaryand control circuit|screw-type terminals| |**type of connectable conductor cross-sections**|| |● solid|1x(0.5 ... 4.0mm²), 2x(0.5 ... 2.5 mm²)| |● finelystranded with core endprocessing|1x(0.5 ... 2.5 mm²), 2x(0.5 ... 1.5 mm²)| |● for AWG cables solid|1x(20 ... 12), 2x(20 ... 14)| |● for AWG cables stranded|1x(20 ... 14), 2x(20 ... 16)| |tighteningtorque with screw-type terminals|0.8 ... 1.2 N·m| |tighteningtorque[lbf·in]with screw-type terminals|7 ... 10.3 lbf·in| |**type of connectable conductor cross-sections for**<br>**PROFIBUS wire**|2x 0.34 mm², AWG 22| |**Ambient conditions**|| |installation altitude at height above sea level maximum|2 000 m| |● note|Restrictions apply to higher installation altitudes, see:<br>https://support.industry.siemens.com/cs/document/109995153| |**ambient temperature**|| |● duringoperation|-25 ... +60 °C| |● duringstorage|-40 ... +80 °C| |● duringtransport|-40 ... +80 °C| |**environmental category**|| |● during operation according to IEC 60721|3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3<br>(no salt mist), 3S2(sand must notget into the devices), 3M6| |● during storage according to IEC 60721|1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2<br>(sand must notget into the devices), 1M4| |● duringtransport accordingto IEC 60721|2K2, 2C1, 2S1, 2M2| |**relative humidity**|| |● duringoperation|5 ... 95 %| |**contact rating of auxiliary contacts according to UL**|B300 / R300| |**Short-circuit protection**|| Subject to change without notice © Copyright Siemens 3UF70001AB000 Page 4/7 6/4/2026 |design of short-circuit protection per output|||Fuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit-|Fuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit-|Fuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit-|Fuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit-|| |---|---|---|---|---|---|---|---| ||||breaker C char.: 1.6 A(IEC 60947-5-1)or 6 A(I_K < 500 A|||K < 500 A)|| |Electrical Safety|||||||| |**touch protection against electrical shock**|||finger-safe||||| |**ATEX**<br>~~a~~|||||||| |**certificate of suitability**|||||||| |● accordingto ATEX directive 2014/34/EU|||BVS 06 ATEX F001||||| |● acc. to Equipment and Protective System Intended for|||ITS21UKEX0464, ITS21UKEX0455X||||| |Use in Potentially Explosive Atmospheres Regulations|||||||| |2016(S.I. 2016 No.1107)|||||||| |● accordingto UKCA|||ITS21UKEX0464||||| |**Galvanic isolation**<br>**(electrically) protective separation according to IEC 60947-1**<br>All circuits with protective separation (double creepage paths and clearances),<br>~~a~~|||||||| ||||the information in the "Protective Separation" test report, No. A0258, must be||||| ||||observed(link see further information)||||| |**design of the electrical isolation**|||Protective separation in accordance with IEC 60947-1 for all circuits, up to||||| ||||installation altitude of 2000 m||||| |● note|||Test report No. A0258 must be observed||||| ||||(https://support.industry.siemens.com/cs/document/109748152)||||| |**Control circuit/ Control**<br>**product function soft starter control**<br>No<br>~~ee~~|||||||| |**type of voltage of the control supply voltage**|||DC||||| |**control supply voltage at DC rated value**|||24 V||||| |**control supply voltage 1 at DC rated value**|||24 V||||| |**operating range factor control supply voltage rated value at**|**operating range factor control supply voltage rated value at**||||||| |**DC**|||||||| |● initial value|||0.8||||| |● full-scale value|||1.2||||| |**inrush currentpeak**<br>● at 24 V<br>~~ee~~|||14 A||||| |**duration of inrush currentpeak**|||||||| |● at 24 V|||0.8 ms||||| |**Approvals Certificates**|||||||| |**Environment**|**General Product Approval**||**General Product Approval**||||| |Environmental Con-|||||||| |firmations|||||||| |**General Product Approval**|**EMV**|||**For use in hazardous locations**|**For use in hazardous locations**||| |c<br>eg|kK||@|||€y)|| |**For use in hazardous locations**|**Test Certificates**|||**Maritime application**|||| |Miscellaneous<br>&) ~~~~ ~~|Type Test Certific-<br>ates/Test Report<br>Special Test Certific-<br>ate<br> ~~—~~~ ~~~~~~~|||©|||| |**Maritime application**|**other**|||||**Industrial Commu-**<br>**nication**|| |©|es)|es)|Confirmation<br>es)|Confirmation|||| Subject to change without notice © Copyright Siemens 3UF70001AB000 Page 5/7 6/4/2026 ## **Further information** ## **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3UF7000-1AB00-0 **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3UF7000-1AB00-0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3UF7000-1AB00-0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3UF7000-1AB00-0&lang=en **==> picture [203 x 225] intentionally omitted <==** Subject to change without notice © Copyright Siemens 3UF70001AB000 Page 6/7 6/4/2026 **==> picture [428 x 239] intentionally omitted <==** **----- Start of picture text -----**<br> Jee Je Jee Je Je Je eee<br>-F ~ |------------------<br>SIEMENS<br>|| + IE 7<br>DEVICE . :<br>Logic<br>BUS<br>GEN. FAULT SIMOCODE PRO<br>i k A )<br>E at<br>PROFIBUS DP<br>PROFIBUS DP<br>se ee<br>A1 9 10 4 5 8 1 6<br>IN1 IN2 IN3 IN4 24V OUT1/2 OUT3<br>PE OUT1 OUT2 OUT3<br>A2 SPE T1 T2 2 3 7 A B DP<br>**----- End of picture text -----**<br> **last modified:** 4/4/2026 Subject to change without notice © Copyright Siemens 3UF70001AB000 Page 7/7 6/4/2026
Updated at March 31, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →