Image not available
Illustrative purposes only
3TK2810-1BA42
Safety Relay, 24 VDC, DPST-NO, SIRIUS Series, DIN Rail, 3 A, Spring Clamp
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Safety Relays
- Product Range: SIRUS 3TK28 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1595.58 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3TK2810-1BA42** **Data sheet** SIRIUS safety relay Safety-oriented Speed monitoring 24 V DC, 45 mm overall width Spring-type terminal EC instantaneous: 2 NO EC delayed: 0 SC: 2 electrical Auto-start/manual start Basic device Maximum achievable PL according to EN 13849-1: e Maximum achievable SIL according to IEC 61508: 3 ||SIRIUS safety relay Safety-oriented Speed monitoring 24 V DC, 45 mm overall<br>width Spring-type terminal EC instantaneous: 2 NO EC delayed: 0 SC: 2 electrical<br>Auto-start/manual start Basic device Maximum achievable PL according to EN<br>13849-1: e Maximum achievable SIL according to IEC 61508: 3| |---|---| |**product brand name**|SIRIUS| |**product designation**|Speed monitor| |**design of theproduct**|standstill and speed monitoring| |**product type designation**|3TK28| |**Product Function**<br>~~|~~|| |**product function**<br>~~|~~|~~|~~| |● automatic start|Yes| |● light barrier monitoring|No| |● standstill monitoring|Yes| |●protective door monitoring|Yes| |● magneticallyoperated switch monitoringNC-NO|No| |● magneticallyoperated switch monitoringNC-NC|No| |● rotation speed monitoring|Yes| |● laser scanner monitoring|No| |● light arraymonitoring|No| |● EMERGENCY OFF function|Yes| |● monitored start-up|Yes| |●pressure-sensitive mat monitoring|No| |**product feature cross-circuit-proof**|Yes| |**suitability for interactionpress control**|No| |**suitability for use**|| |● monitoringof floatingsensors|Yes| |● monitoringof non-floatingsensors|No| |●position switch monitoring|Yes| |● EMERGENCY-OFF circuit monitoring|No| |● valve monitoring|No| |● opto-electronicprotection device monitoring|No| |● tactile sensor monitoring|No| |● magneticallyoperated switch monitoring|No| |●proximityswitch monitoring|Yes| |● safetyswitch|Yes| |● safety-related circuits|Yes| |**General technical data**<br>~~|~~|| |certificate of suitabilityUL approval<br>~~|~~|Yes<br>~~|~~| |**insulation voltage rated value**|300 V| |**surge voltage resistance rated value**|4 000 V| |**protection class IP**|| |● of the enclosure|IP20| |**shock resistance**|8 g / 10 ms| Subject to change without notice © Copyright Siemens 3TK28101BA42 Page 1/6 5/29/2026 |**vibration resistance according to IEC 60068-2-6**|10 ... 55 Hz: 0.35 mm| |---|---| |electrical endurance(operatingcycles)typical|100 000| |**Substance Prohibitance(day/month/year)**|05/01/2012| |**SVHC substance name**|Lead CAS-No. 7439-92-1| |**Net Weight**|0.414 kg| |**Ambient conditions**|| |installation altitude at height above sea level maximum|2 000 m| |● note|installation altitude: 5000 m with derating| |**ambient temperature**|| |● during operation|0 ... 60 °C; from an operating altitude > 2000 m, the maximum permissible<br>temperature is reduced by0.5 °C / 100 m| |● duringstorage|-20 ... +70 °C| |relative humidityduringoperation|10 ... 95 %| |air pressure accordingto SN 31205|90 ... 106 kPa| |**Electromagnetic compatibility**|| |**installation environment regarding EMC**|This product is suitable for Class A environments only. In household<br>environments, this device can cause unwanted radio interference. The user is<br>required to implement appropriate measures in this case.| |**EMC emitted interference**|EN 60947-5-1| |**Safety related data**|| |**stop category according to IEC 60204-1**|0| |IEC 62061|| |SIL Claim Limit(subsystem)accordingto EN 62061|3| |**Safety Integrity Level(SIL) according to IEC 62061**|SIL 3| |PFHD with high demand rate accordingto IEC 62061|3.4E-9 1/h| |ISO 13849|| |categoryaccordingto EN ISO 13849-1|4| |**performance level(PL)**|| |**● according to ISO 13849-1**|PL e| |● for delayed release circuit accordingto ISO 13849-1|e| |IEC 61508|| |**Safety Integrity Level(SIL)**|| |● accordingto IEC 61508|3| |● for delayed release circuit accordingto IEC 61508|SIL3| |**safety device type according to IEC 61508-2**|Type B| |hardware fault tolerance accordingto IEC 61508|1| |T1 value for proof test interval or service life according to IEC<br>61508|20 a| |Electrical Safety|| |**touch protection against electrical shock**|finger-safe| |**Short-circuit protection**|| |design of the fuse link for short-circuit protection of the NO<br>contacts of the relayoutputs required|gL/gG: 4 A| |**Inputs**|| |**design of input**|| |● cascadinginput/functional switching|No| |● feedback input|Yes| |● start input|Yes| |**number of sensor inputs**|| |● 1-channel or 2-channel|0| |● 2-channel|3| |**Outputs**|| |**number of outputs as contact-affected switching element**|| |● as NC contact|| |— for signalingfunction instantaneous contact|0| |— for signalingfunction delayed switching|0| |— safety-related instantaneous contact|0| |— safety-related delayed switching|0| |● as NO contact|| |— for signaling function instantaneous contact|0| Subject to change without notice © Copyright Siemens 3TK28101BA42 Page 2/6 5/29/2026 |— for signalingfunction delayed switching|0| |---|---| |— safety-related instantaneous contact|1| |— safety-related delayed switching|1| |**mechanical service life(operating cycles) typical**|50 000 000| |**thermal current of the switching element with contacts**<br>**maximum**|5 A| |**number of outputs as contact-less semiconductor**<br>**switching element**|| |● for signalingfunction|| |— delayed switching|1| |— instantaneous contact|1| |● safety-related|| |— delayed switching|0| |— instantaneous contact|0| |**switching capacity current of semiconductor outputs**|| |● for signalingfunction at DC-13 at 24 V|0.02 A| |**switching capacity current of the NO contacts of the relay**<br>**outputs at DC-13**|| |● at 24 V|2 A| |● at 115 V|2 A| |**switching capacity current of the NO contacts of the relay**<br>**outputs at AC-15**|| |● at 24 V|3 A| |● at 230 V|3 A| |**switching capacity current of the NC contacts of the relay**<br>**outputs at AC-15**|| |● at 24 V|3 A| |● at 115 V|3 A| |● at 230 V|2 A| |**type of switching output**|optionallyPNP or NPN| |**Encoder**|| |**encoder signal evaluation**|two signal tracks each with inverted signals| |**type of signal level of the encoder**|optionallyTTL, HTL or sin/cos(Ua = 1Vss)| |**type of failure response of the encoder**|high-resistance| |**Proximity switch**|| |**type of voltage of the supply voltage ofproximity switches**|DC| |**supply voltage ofproximity switches**|24 V;provided bythe device| |**current consumption ofproximity switches maximum**|30 mA| |**input voltage forproximity switch minimum**|10 V| |**pulse duration ofproximity switches minimum**|75µs| |**interpulseperiod ofproximity switches minimum**|75µs| |**adjustment range of signal frequency ofproximity switches**|1 Hz ... 2 kHz| |**measuring precision**|+-2 %| |**switching hysteresis**|6.25 %| |**Control circuit/ Control**|| |**type of voltage of the control supply voltage**|DC| |**control supply voltage 1 at DC rated value**|24 V| |**operating range factor control supply voltage rated value of**<br>**magnet coil at DC**|| |● initial value|0.9| |● full-scale value|1.1| |**Installation/ mounting/ dimensions**|| |**mounting position**|any| |**fastening method**|screw and snap-on mounting| |**height**|107.7 mm| |**width**|45 mm| |**depth**|124.3 mm| |**Connections/ Terminals**|| |**type of electrical connection**|spring-loaded terminals| |**type of connectable conductor cross-sections**|| Subject to change without notice © Copyright Siemens 3TK28101BA42 Page 3/6 5/29/2026 |● solid||1x(0.5 ... 4 mm²)|||| |---|---|---|---|---|---| |● finelystranded with core endprocessing||2 x(0.25 ... 1.5 mm²)|||| |● finelystranded without core endprocessing||2x(0.25 ... 1.5 mm²)|||| |● for AWG cables solid||2x(24 ... 16)|||| |● for AWG cables stranded||2x(20 ... 16)|||| |**connectable conductor cross-section**|||||| |● solid||0.25 ... 1.5 mm²|||| |● finelystranded with core endprocessing||0.25 ... 1.5 mm²|||| |● finelystranded without core endprocessing||0.25 ... 1.5 mm²|||| |**AWG number as coded connectable conductor cross**|||||| |**section**|||||| |● solid||24 ... 16|||| |● stranded||24 ... 16|||| |**Approvals Certificates**<br>~~a~~|||||| |**Environment**<br>**General Product Approval**|||||| |Environmental Con-<br>firmations<br>~~—~~<br>FAL<br>«sce<br>~=sCUK|||||| |**Functional Saftey**<br>**Test Certificates**|**other**|||**Railway**|| |Type Examination Cer-<br>Special Test Certific-|Confirmation<br>Confirmation|||Confirmation<br>~~—_~~|| |tificate<br>ate|||||| ~~e~~ **Further information** ~~e~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3TK2810-1BA42 **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3TK2810-1BA42 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3TK2810-1BA42 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3TK2810-1BA42&lang=en Subject to change without notice © Copyright Siemens 3TK28101BA42 Page 4/6 5/29/2026 **==> picture [428 x 572] intentionally omitted <==** **----- Start of picture text -----**<br> 44,8 124,3<br>MCD CDCDCD<br>MDD DCD oT<br>D a EDGID I BADAB G<br>oooo l / > [ i<br>j<br>y<br>U |<br>J<br>=) 2 co<br>b O Ct ; =<br>OOo Ocod Ko) A<br>D O D U DUIDADID I<br>COCOCOCDCDCD LL<br>ODDO<br>COCOCO CODD<br>-F<br>U<br>GND<br>E1<br>E2<br>B A<br>imal<br>8 1<br>109,5<br>A1+ T4 ST MAG T1 EA1 P1 13 23<br>A2- T3 RF1 RF2 T2 EA2 P2 15 25 14 24 LAN<br>**----- End of picture text -----**<br> **last modified:** 5/5/2026 Subject to change without notice © Copyright Siemens 3TK28101BA42 Page 5/6 5/29/2026 Subject to change without notice © Copyright Siemens 3TK28101BA42 Page 6/6 5/29/2026
Updated at April 23, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →