Image not available
Illustrative purposes only
3SK2112-2AA10
Safety Relay, 24 VDC, SIRIUS Series, DIN Rail, 6.5 A, Push In
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Safety Relays
- Product Range: SIRIUS 3SK2 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 528.09 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3SK2112-2AA10** **Data sheet** SIRIUS safety relay basic unit 3SK2 series 10 F-DI, 2 F-DQ, 1 DQ, 24 V DC Can be parameterized via SIRIUS Safety ES 22.5 mm overall width spring-loaded terminal (push-in) up to SIL 3 (IEC 62061) up to performance level e (ISO 13849-1) output expansions 3SK1, coupling relay 3RQ1 and fail-safe motor starters 3RM1 via device connector connectable |**product brand name**|SIRIUS| |---|---| |**product category**|Safetyrelay| |**product designation**|Base-Unit| |**design of theproduct**|10 F-DI, 2 F-DQ, 1 DQ| |**suitability for use for monitoring of optoelectronic**|Yes| |**protective devices according to IEC 61496-1**|| |**suitability for use**|| |● monitoringof floatingsensors|Yes| |● monitoringof non-floatingsensors|Yes| |●position switch monitoring|Yes| |● EMERGENCY-OFF circuit monitoring|Yes| |● valve monitoring|Yes| |● opto-electronicprotection device monitoring|Yes| |● magneticallyoperated switch monitoring|Yes| |●proximityswitch monitoring|Yes| |● safety-related circuits|Yes| |**General technical data**|| |**product function**|| |● EMERGENCY STOP function|Yes| |●protective door monitoring|Yes| |●protective door monitoringwith tumbler|Yes| |● muting, 2 sensor-parallel|Yes| |● muting, 4 sensor-parallel|Yes| |● muting, 4 sensor-sequential|Yes| |● monitoring parameterizable|Yes| |● evaluation: electro-sensitiveprotective equipment|Yes| |● evaluation: selector switch|Yes| |●pressure-sensitive mat monitoring|Yes| |● evaluation: two-hand operatorpanel|Yes| |● evaluation: enablingswitch|Yes| |● monitored start-up|Yes| |● two-hand control accordingto EN 574|Yes| |**configuration software required**|Yes; SafetyES V1.0 and higher| |**number of function blocks typical**|50| |**insulation voltage rated value**|50 V| |**degree ofpollution**|3| |**surge voltage resistance rated value**|800 V| |**protection class IP**|| |● of the enclosure|IP20| 3SK21122AA10 Page 1/6 Subject to change without notice © Copyright Siemens 5/31/2026 |● of the terminal|IP20| |---|---| |**shock resistance**|15g/ 11 ms| |**vibration resistance according to IEC 60068-2-6**|5 ... 500 Hz: 0.75 mm| |**operating frequency maximum**|2 000 1/h| |**reference code according to IEC 81346-2**|F| |**Substance Prohibitance(day/month/year)**|05/28/2009| |**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1| |**Net Weight**|0.197 kg| |**product function suitable for AS-i Power24V**|No| |**product function diagnostics with CTT2 device**|No| |**Ambient conditions**|| |installation altitude at height above sea level maximum|4 000 m| |**ambient temperature**|| |● duringoperation|-25 ... +60 °C| |● duringstorage|-40 ... +80 °C| |● duringtransport|-40 ... +80 °C| |relative humidityduringoperation|10 ... 95 %| |air pressure accordingto SN 31205|90 ... 106 kPa| |**Electromagnetic compatibility**|| |EMC emitted interference accordingto IEC 60947-1|class A| |**conducted interference**|| |● due to burst accordingto IEC 61000-4-4|2 kV(powerports)/ 1 kV(signalports)| |**field-based interference according to IEC 61000-4-3**|10 V/m| |**electrostatic discharge according to IEC 61000-4-2**|4 kV contact discharge / 8 kV air discharge| |**Safety related data**|| |**test wear-related service life necessary**|No| |**diagnostics test interval by internal test function maximum**|1 000 s| |**stop category according to IEC 60204-1**|0 / 1| |IEC 62061|| |SIL Claim Limit(subsystem)accordingto EN 62061|3| |**Safety Integrity Level(SIL)**|| |**● according to IEC 62061**|SIL 3| |● at single-channel evaluation accordingto IEC 62061|1| |● at 2-channel evaluation accordingto IEC 62061|3| |**PFHD with high demand rate**|| |● accordingto IEC 62061|1E-8 1/h| |ISO 13849|| |performance level(PL)accordingto EN ISO 13849-1|e| |categoryaccordingto EN ISO 13849-1|4| |**performance level(PL)**|| |**● according to ISO 13849-1**|PL e| |● at single-channel evaluation accordingto ISO 13849-1|c| |● at 2-channel evaluation accordingto ISO 13849-1|e| |**category**|| |**● according to ISO 13849-1**|4| |● at 2-channel evaluation accordingto ISO 13849-1|4| |**device type according to ISO 13849-1**|1| |**overdimensioning according to ISO 13849-2 necessary**|No| |IEC 61508|| |**Safety Integrity Level(SIL)**|| |● accordingto IEC 61508|3| |● at single-channel evaluation accordingto IEC 61508|1| |● at 2-channel evaluation accordingto IEC 61508|3| |**PFHD with high demand rate according to IEC 61508**|1E-8 1/h| |PFDavgwith low demand rate accordingto IEC 61508|1.5E-5| |**Safe failure fraction (SFF)**|99 %| 3SK21122AA10 Page 2/6 Subject to change without notice © Copyright Siemens 5/31/2026 |**hardware fault tolerance**|| |---|---| |● accordingto IEC 61508|1| |● at single-channel evaluation accordingto IEC 61508|0| |● at 2-channel evaluation accordingto IEC 61508|1| |**T1 value**|| |● of service life accordingto IEC 61508|20 a| |● for proof test interval or service life according to IEC<br>61508|20 a| |Electrical Safety|| |**touch protection against electrical shock**|finger-safe| |**Inputs/ Outputs**|| |**product function**|| |●parameterizable inputs|Yes| |●parameterizable outputs|Yes| |● at the digital outputs short-circuitprotection|Yes| |**number of inputs**|| |● safety-related|10| |● non-safety-related|0| |**input delay time**|0 ... 150 ms| |**type of digital inputs according to IEC 60947-1**|Type 1| |**ingress aquisition time at digital input maximum**|60 ms| |**input delay time at digital input maximum**|150 ms| |input voltage at digital input at DC rated value|24 V| |**input current at digital input**|| |● for signal <1> typical|2.6 mA| |**number of outputs**|| |● safety-related 2-channel|2| |● for testingcontact-based sensors|2| |number of outputs as contact-affected switching element safety-<br>related|| |● 1-channel|0| |● 2-channel|0| |**number of outputs as contact-less semiconductor**<br>**switching element**|| |● safety-related 2-channel|2| |● non-safety-related|1| |**design of the contactless switching element safety-related**|Ppotential| |**recovery time of the safe outputs**|0 ms| |**readback time maximum**|400 ms| |**light testperiod**|3 ms| |**darkperiod of the common drivers**|3 ms| |switching capacity current of semiconductor outputs at DC-13 at<br>24 V|4 A| |**residual current**|| |● maximum|0.1 mA| |● at digital output with signal <0> maximum|0.1 mA| |**total current maximum**|6.5 A| |voltage dropmaximum|0.5 V| |**wire length of the signal cable**|| |● to the inputs|| |— shielded maximum|1 000 m| |— unshielded maximum|600 m| |● to the outputs|| |— shielded maximum|1 000 m| |— unshielded maximum|600 m| |**Communication/ Protocol**|| |**protocol optional is supported**|| |● PROFIBUS DPprotocol|Yes; when usingthe DP interface module; 64 bit cyclical data| |● PROFINET IOprotocol|Yes; when usingthe PN interface module; 64-bit cyclic data| |protocol is supported AS-Interface protocol|No| 3SK21122AA10 Page 3/6 Subject to change without notice © Copyright Siemens 5/31/2026 |**Control circuit/ Control**<br>~~|~~|**Control circuit/ Control**<br>~~|~~|**Control circuit/ Control**<br>~~|~~|**Control circuit/ Control**<br>~~|~~|**Control circuit/ Control**<br>~~|~~|**Control circuit/ Control**<br>~~|~~|**Control circuit/ Control**<br>~~|~~| |---|---|---|---|---|---|---| |**type of voltage**||DC||||| |**control supply voltage rated value**||24 V||||| |**operating range factor control supply voltage rated value at**||||||| |**DC**||||||| |● initial value||0.85||||| |● full-scale value||1.2||||| |**inrush currentpeak**||||||| |● at 24 V||10 A||||| |**duration of inrush currentpeak**||||||| |● at 24 V<br>~~re~~||1 ms||||| |**operating power rated value**||2.5 W||||| |**Installation/ mounting/ dimensions**||||||| |**mounting position**||any||||| |**fastening method**||Snap-mounted to DIN rail or screw-mounted with additionalpush-in lug||||| |**height**||100 mm||||| |**width**<br>~~ee~~||22.5 mm||||| |**depth**||124.5 mm||||| |**Connections/ Terminals**||||||| |**product function removable terminal**||Yes||||| |**type of electrical connection**||spring-loaded terminal(push-in)||||| |**type of connectable conductor cross-sections**||||||| |● solid||1x(0.5 ... 1.5 mm²||0.5 ... 1.5 mm²), 2x(0.5 ... 1.5 mm²)||| |● finelystranded with core endprocessing||1x(0.5 ... 1.0 mm²||0.5 ... 1.0 mm²), 2x(0.5 ... 1.0 mm²)||| |● for AWG cables solid||1x(20 ... 16), 2x||, 2x(20 ... 16)||| |● for AWG cables stranded||1x(20 ... 16), 2x||, 2x(20 ... 16)||| |connectable conductor cross-section finely stranded with core||0.5 ... 1 mm²||||| |endprocessing||||||| |**AWG number as coded connectable conductor cross**||||||| |**section**||||||| |● solid||20 ... 16||||| |● stranded||20 ... 16||||| |**Approvals Certificates**<br>~~ee~~||||||| |**Environment**<br>**General Product Approval**||||||**EMV**| |Environmental Con-<br>firmations<br>~~—~~<br>@<br>“fA||||Se|cg|[G| |**EMV**<br>**Functional Saftey**<br>**Test Certificates**||**other**||||| |Type Examination Cer-<br>tificate<br>Type Test Certific-<br>ates/Test Report<br>Confirmation<br>Confirmation<br>**Further information**<br>**Information on the packaging**<br>~~re~~<br>~~OO~~<br>~~—C™SCSC“‘CSCOC:C‘isCs~~||||||| |https://support.industry.siemens.com/cs/ww/en/view/109813875||||||| |**Information for data generation and storage**||||||| |https://support.industry.siemens.com/cs/ww/en/view/109995012||||||| |**Information- and Downloadcenter (Catalogs, Brochures,…)**||||||| |https://www.siemens.com/ic10||||||| |**Industry Mall (Online ordering system)**||||||| |https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3SK2112-2AA10||||||| |**Cax online generator**||||||| |https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3SK2112-2AA10||||||| |**Service&Support (Manuals, Certificates, Characteristics, FAQs,...)**||||||| |https://support.industry.siemens.com/cs/ww/en/ps/3SK2112-2AA10||||||| |**Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)**||||**Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)**||| |https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3SK2112-2AA10&lang=en||||||| 3SK21122AA10 Page 4/6 Subject to change without notice © Copyright Siemens 5/31/2026 **==> picture [461 x 356] intentionally omitted <==** **----- Start of picture text -----**<br> -K<br>24V+<br>|<br>|<br>|<br>|<br>|<br>|<br>|<br>|<br>|<br>Logic<br>X1 | |<br>|<br>|<br>|<br>|<br>| |<br>|<br>|<br>|<br>|<br>| - |<br>|<br>last modified: 4/4/2026<br>A1+ T1 F-IN1 F-IN3 F-IN5 F-IN7 F-IN9 T2 F-IN2 F-IN4 F-IN6 F-IN8 F-IN10<br>SYS<br>FE A2-<br>F-Q1 F-Q2 QM1<br>**----- End of picture text -----**<br> 3SK21122AA10 Page 5/6 Subject to change without notice © Copyright Siemens 5/31/2026 3SK21122AA10 Page 6/6 Subject to change without notice © Copyright Siemens 5/31/2026
Updated at April 23, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →