Image not available
Illustrative purposes only
3SK1122-1CB42
Safety Relay, 24 VDC, 4PST-NO, SIRIUS Series, DIN Rail, 2 A, Screw
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Safety Relays
- Product Range: SIRIUS 3SK1 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 257.52 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3SK1122-1CB42** **Data sheet** SIRIUS safety relay Basic unit Advanced series with time delay 0.5-30 s electronic enabling circuits 2 NO instantaneous 2 NO delayed Us = 24 V DC screw terminal |SIRIUS safety relay Basic unit Advanced series with time delay 0.5-30 s electronic<br>enabling circuits 2 NO instantaneous 2 NO delayed Us = 24 V DC screw terminal<br>**product brand name**<br>SIRIUS<br>**product category**<br>Safetyrelays<br>**product designation**<br>safetyrelays<br>**design of theproduct**<br>Solid-state enablingcircuits<br>**product type designation**<br>3SK1<br>**product line**<br>Advanced basic unit<br>**Product Function**<br>**product function parameterizable**<br>sensor floating / sensor non-floating, monitored start-up / automatic start, 1-<br>channel / 2-channel sensor connection, cross-circuit detection, startup testing,<br>antivalent sensors, 2-hand switches, time delay<br>**product function**<br>● automatic start<br>Yes<br>● light barrier monitoring<br>Yes<br>●protective door monitoring<br>Yes<br>● magneticallyoperated switch monitoringNC-NO<br>Yes<br>● magneticallyoperated switch monitoringNC-NC<br>Yes<br>● laser scanner monitoring<br>Yes<br>● light arraymonitoring<br>Yes<br>● EMERGENCY OFF function<br>Yes<br>● monitored start-up<br>Yes<br>●pressure-sensitive mat monitoring<br>No<br>**product feature cross-circuit-proof**<br>Yes<br>**suitability for interactionpress control**<br>Yes<br>**suitability for operation device connector 3ZY12**<br>Yes<br>**suitability for use**<br>● monitoringof floatingsensors<br>Yes<br>● monitoringof non-floatingsensors<br>Yes<br>●position switch monitoring<br>Yes<br>● EMERGENCY-OFF circuit monitoring<br>Yes<br>● opto-electronicprotection device monitoring<br>Yes<br>● magneticallyoperated switch monitoring<br>Yes<br>● safetyswitch<br>Yes<br>● safety-related circuits<br>Yes<br>**General technical data**<br>certificate of suitabilityUL approval<br>Yes<br>**power loss[W] maximum**<br>2 W<br>**insulation voltage rated value**<br>50 V<br>**degree ofpollution**<br>3<br>**overvoltage category**<br>3<br>**surge voltage resistance rated value**<br>800 V<br>~~|~~<br>~~|~~|SIRIUS safety relay Basic unit Advanced series with time delay 0.5-30 s electronic<br>enabling circuits 2 NO instantaneous 2 NO delayed Us = 24 V DC screw terminal|| |---|---|---| ||SIRIUS|| ||Safetyrelays|| ||safetyrelays|| ||Solid-state enablingcircuits|| ||3SK1|| ||Advanced basic unit|| ||Yes<br>~~|~~|| ||2 W|| ||50 V|| ||3|| ||3|| ||800 V|| 3SK11221CB42 Page 1/6 Subject to change without notice © Copyright Siemens 5/30/2026 |protection class IP of the enclosure|IP20| |---|---| |**shock resistance**|10g/ 11 ms| |**vibration resistance according to IEC 60068-2-6**|5 ... 500 Hz: 0.75 mm| |**operating frequency maximum**|2 000 1/h| |**reference code according to IEC 81346-2**|F| |**Substance Prohibitance(day/month/year)**|11/05/2012| |**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1<br>6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1| |**Net Weight**|0.196 kg| |**Ambient conditions**|| |installation altitude at height above sea level maximum|4 000 m| |● note|Derating, see Product Notification 109792701| |**ambient temperature**|| |● duringoperation|-25 ... +60 °C| |● duringstorage|-40 ... +80 °C| |relative humidityduringoperation|10 ... 95 %| |air pressure accordingto SN 31205|900 ... 1 060 hPa| |**Electromagnetic compatibility**|| |**installation environment regarding EMC**|This product is suitable for Class A environments only. In household<br>environments, this device can cause unwanted radio interference. The user is<br>required to implement appropriate measures in this case.| |**EMC emitted interference**|IEC 60947-5-1, Class A| |**Safety related data**|| |product function suitable for safetyfunction|Yes| |**safe state**|Safetyoutputs switched off| |**test wear-related service life necessary**|No| |**diagnostics test interval by internal test function maximum**|600 s| |**stop category according to IEC 60204-1**|0 / 1| |IEC 62061|| |SIL Claim Limit(subsystem)accordingto EN 62061|3| |**Safety Integrity Level(SIL)**|| |**● according to IEC 62061**|SIL 3| |● at single-channel evaluation accordingto IEC 62061|1| |● at 2-channel evaluation accordingto IEC 62061|3| |**PFHD with high demand rate according to IEC 62061**|0,0000000015| |ISO 13849|| |categoryaccordingto EN ISO 13849-1|4| |**performance level(PL)**|| |**● according to ISO 13849-1**|PL e| |● at single-channel evaluation accordingto ISO 13849-1|c| |● at 2-channel evaluation accordingto ISO 13849-1|e| |● for delayed release circuit accordingto ISO 13849-1|e| |**category**|| |**● according to ISO 13849-1**|4| |● at 2-channel evaluation accordingto ISO 13849-1|4| |**overdimensioning according to ISO 13849-2 necessary**|No| |IEC 61508|| |**Safety Integrity Level(SIL)**|| |● accordingto IEC 61508|3| |● for delayed release circuit accordingto IEC 61508|SIL3| |● at single-channel evaluation accordingto IEC 61508|1| |● at 2-channel evaluation accordingto IEC 61508|3| |**safety device type according to IEC 61508-2**|Type B| |**Safe failure fraction(SFF)**|99 %| |**hardware fault tolerance**|| |● accordingto IEC 61508|1| |● at single-channel evaluation according to IEC 61508|0| 3SK11221CB42 Page 2/6 Subject to change without notice © Copyright Siemens 5/30/2026 ||● at 2-channel evaluation accordingto IEC 61508|1|| |---|---|---|---| ||**T1 value**||| ||● of service life accordingto IEC 61508|20 a|| ||● for proof test interval or service life according to IEC<br>61508|20 a|| ||Electrical Safety||| ||**touch protection against electrical shock**|finger-safe|| ||**Short-circuit protection**||| ||**design of the fuse link**||| ||● for short-circuit protection of the NO contacts of the relay<br>outputs required|not required|| ||**Inputs**||| ||**design of input**||| ||● cascadinginput/functional switching|Yes|| ||● feedback input|Yes|| ||● start input|Yes|| ||pulse duration of the sensor input minimum|60 ms|| ||number of sensor inputs 1-channel or 2-channel|1|| ||**Outputs**||| ||**number of outputs as contact-affected switching element**||| ||● as NO contact||| ||— safety-related instantaneous contact|0|| ||— safety-related delayed switching|0|| ||**number of outputs as contact-less semiconductor**<br>**switching element**||| ||● for signalingfunction||| ||— instantaneous contact|0|| ||● safety-related||| ||— delayed switching|2|| ||— instantaneous contact|2|| ||switching capacity current of semiconductor outputs at DC-13 at<br>24 V|2 A|| ||**Times**||| ||**make time with automatic start**||| ||● at DC maximum|85 ms|| ||**make time with automatic start afterpower failure**||| ||● typical|6 500 ms|| ||● maximum|6 500 ms|| ||**make time with monitored start**||| ||● maximum|85 ms|| ||**backslide delay time after opening of the safety circuits**<br>**typical**|40 ms|| ||**adjustable OFF-delay time after opening of the safety**<br>**circuits**|0.5 ... 30 s|| ||**recovery time after opening of the safety circuits typical**|30 ms|| ||**recovery time afterpower failure typical**|6.5 s|| ||**pulse duration**||| ||● of the ON pushbutton input minimum|0.15 s|| ||**Control circuit/ Control**||| ||**type of voltage of the control supply voltage**|DC|| ||**control supply voltage at DC rated value**|24 V|| ||**operating range factor control supply voltage rated value of**<br>**magnet coil at DC**||| ||● initial value|0.8|| ||● full-scale value|1.2|| ||**Installation/ mounting/ dimensions**||| ||**mounting position**|any|| ||**fastening method**|screw and snap-on mounting|| ||**height**|100 mm|| ||**width**|22.5 mm|| ||**depth**|121.5 mm|| 3SK11221CB42 Page 3/6 Subject to change without notice © Copyright Siemens 5/30/2026 ## **required spacing** |● forgrounded parts at the side||5 mm|5 mm|||||| |---|---|---|---|---|---|---|---|---| |**Connections/ Terminals**<br>~~er~~||||||||| |**type of electrical connection**||screw terminal||screw terminal||||| |**wire length**||||||||| |● with Cu 1.5 mm² and 150 nF/km per sensor circuit||4 000 m||4 000 m||||| |maximum||||||||| |**type of connectable conductor cross-sections**||||||||| |● solid||1x(0.5 ... 2.5 mm²), 2x(1.0 ... 1.5 mm²|||1.0 ... 1.5 mm²)|||| |● finelystranded with core endprocessing||1x(0.5 ... 2.5 mm²), 2x(0.5 ... 1.0 mm²|||0.5 ... 1.0 mm²)|||| |● for AWG cables solid||1x(20 ... 14||20 ... 14), 2x(18 ... 16)||||| |● for AWG cables stranded||1x(20 ... 16||20 ... 16), 2x(20 ... 16)||||| |**type of electrical connection plug-in socket**||No||||||| |**Approvals Certificates**<br>~~a~~||||||||| |**Environment**|**General Product Approval**|||||||| |Environmental Con-||||||||| |firmations||||||||| |**General Product Ap-**<br>**proval**<br>**EMV**||||**Functional Saftey**||**Test Certificates**|**Maritime application**|| |||||Type Examination Cer-||Type Test Certific-||| |||||tificate||ates/Test Report||| |**Maritime application**||||**other**||||| |Confirmation<br>Confirmation<br>~~=~~<br>~~Oo~~||||||||| |**Railway**||||||||| |Confirmation||||||||| ~~e~~ **Further information** ~~e~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3SK1122-1CB42 **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3SK1122-1CB42 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3SK1122-1CB42 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3SK1122-1CB42&lang=en 3SK11221CB42 Page 4/6 Subject to change without notice © Copyright Siemens 5/30/2026 **==> picture [511 x 718] intentionally omitted <==** **----- Start of picture text -----**<br> -K<br>1 | Autostart / Monitored Start<br>Logic<br>2 | Cross fault detection OFF / ON<br>3 | 2 single-ch. sensors / 1 double-ch. sensor<br>4 | Startup Test yes / no<br>SET / RESET<br>A1+ INK IN1 T1 PAR IN2 T2 INF INS<br>SYS<br>2- 1 2 t1 t2<br>A Q Q Q Q<br>**----- End of picture text -----**<br> 3SK11221CB42 Page 5/6 Subject to change without notice © Copyright Siemens 5/30/2026 **last modified:** **==> picture [34 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 5/26/2026<br>**----- End of picture text -----**<br> 3SK11221CB42 Page 6/6 Subject to change without notice © Copyright Siemens 5/30/2026
Updated at April 23, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →