Image not available
Illustrative purposes only
3SK1112-2BB40
Safety Relay, 24 VDC, SIRIUS Series, DIN Rail, 2 A, Push In
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Safety Relays
- Product Range: SIRIUS 3SK1 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 217.5 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3SK1112-2BB40** **Data sheet** SIRIUS safety relay Basic unit Standard series electronic enabling circuits 2 enabling circuits plus 1 signaling circuit Us = 24 V DC Spring-type terminal (pushin) |'<br>'<br>£|SIRIUS safety relay Basic unit Standard series electronic enabling circuits 2<br>enabling circuits plus 1 signaling circuit Us = 24 V DC Spring-type terminal (push-<br>in)| |---|---| |**product brand name**|SIRIUS| |**product category**|Safetyrelays| |**product designation**|safetyrelays| |**design of theproduct**|Solid-state enablingcircuits| |**product type designation**|3SK1| |**product line**|Standard basic unit| |**Product Function**|| |**product function parameterizable**|sensor floating / sensor non-floating, monitored start-up / automatic start, 1-<br>channel / 2-channel sensor connection, cross-circuit detection, startuptesting| |**product function**|| |● automatic start|Yes| |● light barrier monitoring|Yes| |●protective door monitoring|Yes| |● magneticallyoperated switch monitoringNC-NO|No| |● magneticallyoperated switch monitoringNC-NC|Yes| |● laser scanner monitoring|Yes| |● light arraymonitoring|Yes| |● EMERGENCY OFF function|Yes| |● monitored start-up|Yes| |●pressure-sensitive mat monitoring|No| |**product feature cross-circuit-proof**|Yes| |**suitability for interactionpress control**|No| |**suitability for operation device connector 3ZY12**|No| |**suitability for use**|| |● monitoringof floatingsensors|Yes| |● monitoringof non-floatingsensors|Yes| |●position switch monitoring|Yes| |● EMERGENCY-OFF circuit monitoring|Yes| |● opto-electronicprotection device monitoring|Yes| |● magneticallyoperated switch monitoring|Yes| |● safetyswitch|Yes| |● safety-related circuits|Yes| |**General technical data**|| |certificate of suitabilityUL approval|Yes| |**power loss[W] maximum**|2 W| |**insulation voltage rated value**|50 V| |**degree ofpollution**|3| |**overvoltage category**|3| |**surge voltage resistance rated value**|800 V| 3SK11122BB40 Page 1/6 Subject to change without notice © Copyright Siemens 5/29/2026 |protection class IP of the enclosure|IP20| |---|---| |**shock resistance**|10g/ 11 ms| |**vibration resistance according to IEC 60068-2-6**|5 ... 500 Hz: 0.75 mm| |**operating frequency maximum**|2 000 1/h| |**reference code according to IEC 81346-2**|F| |**Substance Prohibitance(day/month/year)**|11/05/2012| |**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1<br>6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1| |**Net Weight**|0.152 kg| |**Ambient conditions**|| |installation altitude at height above sea level maximum|4 000 m| |● note|Derating, see Product Notification 109792701| |**ambient temperature**|| |● duringoperation|-25 ... +60 °C| |● duringstorage|-40 ... +80 °C| |relative humidityduringoperation|10 ... 95 %| |air pressure accordingto SN 31205|900 ... 1 060 hPa| |**Electromagnetic compatibility**|| |**installation environment regarding EMC**|This product is suitable for Class A environments only. In household<br>environments, this device can cause unwanted radio interference. The user is<br>required to implement appropriate measures in this case.| |**EMC emitted interference**|IEC 60947-5-1, Class A| |**Safety related data**|| |product function suitable for safetyfunction|Yes| |**safe state**|Safetyoutputs switched off| |**test wear-related service life necessary**|No| |**diagnostics test interval by internal test function maximum**|600 s| |**stop category according to IEC 60204-1**|0| |IEC 62061|| |SIL Claim Limit(subsystem)accordingto EN 62061|3| |**Safety Integrity Level(SIL)**|| |**● according to IEC 62061**|SIL 3| |● at single-channel evaluation accordingto IEC 62061|1| |● at 2-channel evaluation accordingto IEC 62061|3| |**PFHD with high demand rate according to IEC 62061**|0,0000000010| |ISO 13849|| |categoryaccordingto EN ISO 13849-1|4| |**performance level(PL)**|| |**● according to ISO 13849-1**|PL e| |● at single-channel evaluation accordingto ISO 13849-1|c| |● at 2-channel evaluation accordingto ISO 13849-1|e| |**category**|| |**● according to ISO 13849-1**|4| |● at 2-channel evaluation accordingto ISO 13849-1|4| |**overdimensioning according to ISO 13849-2 necessary**|No| |IEC 61508|| |**Safety Integrity Level(SIL)**|| |● accordingto IEC 61508|3| |● at single-channel evaluation accordingto IEC 61508|1| |● at 2-channel evaluation accordingto IEC 61508|3| |**safety device type according to IEC 61508-2**|Type B| |**PFHD with high demand rate according to IEC 61508**|0,0000000010| |**Safe failure fraction(SFF)**|99 %| |**hardware fault tolerance**|| |● accordingto IEC 61508|1| |● at single-channel evaluation accordingto IEC 61508|0| |● at 2-channel evaluation according to IEC 61508|1| 3SK11122BB40 Page 2/6 Subject to change without notice © Copyright Siemens 5/29/2026 |**T1 value**|| |---|---| |● of service life accordingto IEC 61508|20 a| |● for proof test interval or service life according to IEC<br>61508|20 a| |Electrical Safety|| |**touch protection against electrical shock**|finger-safe| |**Short-circuit protection**|| |**design of the fuse link**|| |● for short-circuit protection of the NO contacts of the relay<br>outputs required|not required| |**Inputs**|| |**design of input**|| |● cascadinginput/functional switching|Yes| |● feedback input|Yes| |● start input|Yes| |pulse duration of the sensor input minimum|60 ms| |number of sensor inputs 1-channel or 2-channel|1| |**Outputs**|| |**number of outputs as contact-affected switching element**|| |● as NO contact|| |— safety-related instantaneous contact|0| |— safety-related delayed switching|0| |**number of outputs as contact-less semiconductor**<br>**switching element**|| |● for signalingfunction|| |— instantaneous contact|1| |● safety-related|| |— delayed switching|0| |— instantaneous contact|2| |switching capacity current of semiconductor outputs at DC-13 at<br>24 V|2 A| |**Times**|| |**make time with automatic start**|| |● at DC maximum|85 ms| |**make time with automatic start afterpower failure**|| |● typical|6 500 ms| |● maximum|6 500 ms| |**make time with monitored start**|| |● maximum|85 ms| |**backslide delay time after opening of the safety circuits**<br>**typical**|40 ms| |**recovery time after opening of the safety circuits typical**|30 ms| |**recovery time afterpower failure typical**|6.5 s| |**pulse duration**|| |● of the ON pushbutton input minimum|0.15 s| |**Control circuit/ Control**|| |**type of voltage of the control supply voltage**|DC| |**control supply voltage at DC rated value**|24 V| |**operating range factor control supply voltage rated value of**<br>**magnet coil at DC**|| |● initial value|0.8| |● full-scale value|1.2| |**Installation/ mounting/ dimensions**|| |**mounting position**|any| |**fastening method**|screw and snap-on mounting| |**height**|100 mm| |**width**|22.5 mm| |**depth**|91.5 mm| |**required spacing**|| |● for grounded parts at the side|5 mm| 3SK11122BB40 Page 3/6 Subject to change without notice © Copyright Siemens 5/29/2026 ~~re~~ **Connections/ Terminals type of electrical connection** spring-loaded terminal (push-in) **wire length** ● with Cu 1.5 mm² and 150 nF/km per sensor circuit 4 000 m maximum **type of connectable conductor cross-sections** ● solid 1x (0.5 ... 1.5 mm²), 2x (0.5 ... 1.5 mm²) ● finely stranded with core end processing 1x (0.5 ... 1.0 mm²), 2x (0.5 ... 1.0 mm²) ● finely stranded without core end processing 1x (0.5 ... 1.5 mm²), 2x (0.5 ... 1.5 mm²) ● for AWG cables solid 1x (20 ... 16), 2x (20 ... 16) ● for AWG cables stranded 1x (20 ... 16), 2x (20 ... 16) **type of electrical connection plug-in socket** No ~~ee~~ **Approvals Certificates Environment General Product Approval** Environmental Confirmations **General Product ApEMV Functional Saftey Test Certificates Maritime application proval** - - Type Examination Cer Type Test Certific UK ~~———_~~ tificate ates/Test Report **Maritime application other** Confirmation Confirmation - ~~OS~~ **Railway** Confirmation ~~e~~ **Further information** ~~e~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3SK1112-2BB40 **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3SK1112-2BB40 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3SK1112-2BB40 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3SK1112-2BB40&lang=en 3SK11122BB40 Page 4/6 Subject to change without notice © Copyright Siemens 5/29/2026 **==> picture [511 x 718] intentionally omitted <==** **----- Start of picture text -----**<br> -K<br>1 | Autostart / Monitored Start Logic<br>2 | Cross fault detection OFF / ON<br>3 | 2 single-ch. sensors / 1 double-ch. sensor<br>4 | Startup Test yes / no<br>SET / RESET<br>A1+ INK T1 IN1 T2 IN2 INF INS<br>1 2<br>Q Q<br>A2- QM1<br>**----- End of picture text -----**<br> 3SK11122BB40 Page 5/6 Subject to change without notice © Copyright Siemens 5/29/2026 **last modified:** **==> picture [34 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 5/26/2026<br>**----- End of picture text -----**<br> 3SK11122BB40 Page 6/6 Subject to change without notice © Copyright Siemens 5/29/2026
Updated at April 23, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →