Image not available
Illustrative purposes only
3SK1111-2AW20
Safety Relay, 240 VAC/VDC, 3PST-NO, SPST-NC, SIRIUS Series, DIN Rail, 5 A, Push In
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Safety Relays
- Product Range: SIRIUS 3SK1 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 269.7 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3SK1111-2AW20** **Data sheet** ||SIRIUS safety relay Basic unit Standard series Relay enabling circuits 3 NO<br>contacts plus Relay signaling circuit 1 NC contact Us = 110 - 240 V AC/DC 50/60<br>Hz Spring-type terminal (push-in)| |---|---| |**product brand name**|SIRIUS| |**product category**|Safetyrelays| |**product designation**|safetyrelays| |**design of theproduct**|Relayenablingcircuits| |**product type designation**|3SK1| |**product line**|Standard basic unit| |**Product Function**<br>~~|~~|| |**product functionparameterizable**<br>~~|~~|Sensor floating/ monitored start / automatic start<br>~~|~~| |**product function**|| |● automatic start|Yes| |● light barrier monitoring|No| |●protective door monitoring|Yes| |● magneticallyoperated switch monitoringNC-NO|No| |● magneticallyoperated switch monitoringNC-NC|Yes| |● laser scanner monitoring|No| |● light arraymonitoring|No| |● EMERGENCY OFF function|Yes| |● monitored start-up|Yes| |●pressure-sensitive mat monitoring|No| |**product feature cross-circuit-proof**|Yes| |**suitability for interactionpress control**|No| |**suitability for operation device connector 3ZY12**|No| |**suitability for use**|| |● monitoringof floatingsensors|Yes| |● monitoringof non-floatingsensors|No| |●position switch monitoring|Yes| |● EMERGENCY-OFF circuit monitoring|Yes| |● opto-electronicprotection device monitoring|No| |● magneticallyoperated switch monitoring|No| |● safetyswitch|Yes| |● safety-related circuits|Yes| |**General technical data**<br>~~|~~|| |certificate of suitabilityUL approval<br>~~|~~|Yes<br>~~|~~| |**power loss[W] maximum**|2.5 W| |**insulation voltage rated value**|300 V| |**degree ofpollution**|3| |**overvoltage category**|3| |**surge voltage resistance rated value**|4 000 V| |protection class IP of the enclosure|IP20| |**shock resistance**|10g/ 11 ms| |**vibration resistance according to IEC 60068-2-6**|5 ... 500 Hz: 0.75 mm| |**operating frequency maximum**|360 1/h| |**reference code according to IEC 81346-2**|F| |**Substance Prohibitance(day/month/year)**|11/05/2012| |**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1<br>6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1| 3SK11112AW20 Page 1/5 Subject to change without notice © Copyright Siemens 5/30/2026 ||4,4'-isopropylidenediphenol(Bisphenol A, BPA)CAS-No. 80-05-7| |---|---| |**Net Weight**|0.243 kg| |**Ambient conditions**|| |installation altitude at height above sea level maximum|4 000 m| |● note|Derating, see Product Notification 109792701| |**ambient temperature**|| |● duringoperation|-25 ... +60 °C| |● duringstorage|-40 ... +80 °C| |relative humidityduringoperation|10 ... 95 %| |air pressure accordingto SN 31205|900 ... 1 060 hPa| |**Electromagnetic compatibility**|| |**installation environment regarding EMC**|This product is suitable for Class A environments only. In household<br>environments, this device can cause unwanted radio interference. The user is<br>required to implement appropriate measures in this case.| |**EMC emitted interference**|IEC 60947-5-1, Class A| |**Safety related data**|| |product function suitable for safetyfunction|Yes| |**safe state**|Safetyoutputs switched off| |**test wear-related service life necessary**|Yes| |**function test interval maximum**|1 a| |**stop category according to IEC 60204-1**|0| |IEC 62061|| |SIL Claim Limit(subsystem)accordingto EN 62061|3| |**Safety Integrity Level(SIL)**|| |**● according to IEC 62061**|SIL 3| |● at single-channel evaluation accordingto IEC 62061|1| |● at 2-channel evaluation accordingto IEC 62061|3| |**PFHD with high demand rate according to IEC 62061**|0,0000000015| |ISO 13849|| |categoryaccordingto EN ISO 13849-1|4| |**performance level(PL)**|| |**● according to ISO 13849-1**|PL e| |● at single-channel evaluation accordingto ISO 13849-1|c| |● at 2-channel evaluation accordingto ISO 13849-1|e| |**category**|| |**● according to ISO 13849-1**|4| |● at 2-channel evaluation accordingto ISO 13849-1|4| |**overdimensioning according to ISO 13849-2 necessary**|No| |IEC 61508|| |**Safety Integrity Level(SIL)**|| |● accordingto IEC 61508|3| |● at single-channel evaluation accordingto IEC 61508|1| |● at 2-channel evaluation accordingto IEC 61508|3| |**safety device type according to IEC 61508-2**|Type A| |**Safe failure fraction(SFF)**|99 %| |**hardware fault tolerance**|| |● accordingto IEC 61508|1| |● at single-channel evaluation accordingto IEC 61508|0| |● at 2-channel evaluation accordingto IEC 61508|1| |**T1 value**|| |● of service life accordingto IEC 61508|20 a| |● for proof test interval or service life according to IEC<br>61508|20 a| |Electrical Safety|| |**touch protection against electrical shock**|finger-safe| |**Short-circuit protection**|| |**design of the fuse link**|| |● for short-circuit protection of the NO contacts of the relay<br>outputs required|gL/gG: 6A or circuit breaker type A: 3A or circuit breaker type B: 2A or circuit<br>breaker type C: 1A| |● for short circuit protection of the NC contacts of the relay|Diazed or Neozed fuses, operating class gL/gG: 6 A or MCB type A: 2 A or| 3SK11112AW20 Page 2/5 Subject to change without notice © Copyright Siemens 5/30/2026 |outputs required|MCB type B: 2 A or MCB type C: 1 A| |---|---| |**Inputs**|| |**design of input**|| |● cascadinginput/functional switching|No| |● feedback input|Yes| |● start input|Yes| |pulse duration of the sensor input minimum|150 ms| |number of sensor inputs 1-channel or 2-channel|1| |**Outputs**|| |**number of outputs as contact-affected switching element**|| |● as NC contact|| |— for signalingfunction instantaneous contact|1| |● as NO contact|| |— safety-related instantaneous contact|3| |— safety-related delayed switching|0| |**mechanical service life(operating cycles) typical**|10 000 000| |**thermal current of the switching element with contacts**<br>**maximum**|5 A| |**switching capacity current of the NO contacts of the relay**<br>**outputs at DC-13**|| |● at 24 V|5 A| |● at 115 V|0.2 A| |● at 230 V|0.1 A| |**switching capacity current of the NO contacts of the relay**<br>**outputs at AC-15**|| |● at 115 V|5 A| |● at 230 V|5 A| |**switching capacity current of the NC contacts of the relay**<br>**outputs at DC-13**|| |● at 24 V|1 A| |● at 115 V|0.2 A| |● at 230 V|0.1 A| |**switching capacity current of the NC contacts of the relay**<br>**outputs at AC-15**|| |● at 24 V|2 A| |● at 115 V|1.5 A| |● at 230 V|1.5 A| |**total current maximum**|12 A| |**operational current at 17 V minimum**|5 mA| |**Times**|| |**make time with automatic start**|| |● typical|110 ms| |● at DC maximum|130 ms| |● at AC maximum|130 ms| |**make time with automatic start afterpower failure**|| |● typical|110 ms| |● maximum|130 ms| |**make time with monitored start**|| |● typical|15 ms| |● maximum|15 ms| |**backslide delay time after opening of the safety circuits**<br>**typical**|10 ms| |**backslide delay time in the event ofpower failure**|| |● typical|200 ms| |● maximum|300 ms| |**recovery time after opening of the safety circuits typical**|10 ms| |**recovery time afterpower failure typical**|0.32 s| |**pulse duration**|| |● of the ON pushbutton input minimum|0.015 s| |**Control circuit/ Control**|| 3SK11112AW20 Page 3/5 Subject to change without notice © Copyright Siemens 5/30/2026 |**type of voltage of the control supply voltage**|AC/DC| |---|---| |**control supply voltage at AC**|| |● at 50 Hz rated value|110 ... 240 V| |● at 60 Hz rated value|110 ... 240 V| |**control supply voltage frequency**|| |**● 1 rated value**|50 Hz| |**● 2 rated value**|60 Hz| |**control supply voltage at DC rated value**|110 ... 240 V| |**operating range factor control supply voltage rated value of**|| |**magnet coil at DC**|| |● initial value|0.85| |● full-scale value|1.1| |**operating range factor control supply voltage rated value of**|| |**magnet coil at AC**|| |● at 50 Hz|0.85 ... 1.1| |● at 60 Hz|0.85 ... 1.1| |**Installation/ mounting/ dimensions**<br>~~ee~~|| |**mounting position**|any| |**fastening method**|screw and snap-on mounting| |**height**|100 mm| |**width**|22.5 mm| |**depth**|121.5 mm| |**required spacing**|| ● for grounded parts at the side 5 mm ~~a~~ **Connections/ Terminals type of electrical connection** spring-loaded terminal (push-in) **wire length** ● for total of all sensor circuits with Cu 1.5 mm² and 150 2 000 m nF/km maximum **type of connectable conductor cross-sections** ● solid 1x (0.5 ... 1.5 mm²), 2x (0.5 ... 1.5 mm²) ● finely stranded with core end processing 1x (0.5 ... 1.0 mm²), 2x (0.5 ... 1.0 mm²) ● finely stranded without core end processing 1x (0.5 ... 1.5 mm²), 2x (0.5 ... 1.5 mm²) ● for AWG cables solid 1x (20 ... 16), 2x (20 ... 16) ● for AWG cables stranded 1x (20 ... 16), 2x (20 ... 16) **type of electrical connection plug-in socket** No |**Approvals Certificates**<br>~~ee~~|**Approvals Certificates**<br>~~ee~~|**Approvals Certificates**<br>~~ee~~|**Approvals Certificates**<br>~~ee~~|**Approvals Certificates**<br>~~ee~~|**Approvals Certificates**<br>~~ee~~| |---|---|---|---|---|---| |**Environment**||**General Product Approval**|||| |Environmental Con-|||||| |firmations|||||| |**General Product Ap-**<br>**proval**|**EMV**||**Functional Saftey**|**Test Certificates**|**Maritime application**| ||||Type Examination Cer-|Type Test Certific-|| ||||tificate|ates/Test Report|| |**Maritime application**|||**other**||| |2|||Confirmation<br>~~—~~|Confirmation|| **Railway** 3SK11112AW20 Page 4/5 Subject to change without notice © Copyright Siemens 5/30/2026 Confirmation |**Further information**||| |---|---|---| |**Information on the packaging**||| |https://support.industry.siemens.com/cs/ww/en/view/109813875||| |**Information for data generation and storage**||| |https://support.industry.siemens.com/cs/ww/en/view/109995012||| |**Information- and Downloadcenter (Catalogs, Brochures,…)**||| |https://www.siemens.com/ic10||| |**Industry Mall (Online ordering system)**||| |https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3SK1111-2AW20||| |**Cax online generator**||| |https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3SK1111-2AW20||| |**Service&Support (Manuals, Certificates, Characteristics, FAQs,...)**||| |https://support.industry.siemens.com/cs/ww/en/ps/3SK1111-2AW20||| |**Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)**||| |https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3SK1111-2AW20&lang=en||| |**last modified:**|5/26/2026|G| 3SK11112AW20 Page 5/5 Subject to change without notice © Copyright Siemens 5/30/2026
Updated at April 23, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.