3RW5547-2HF14
Soft Starter, 3RW Series, Three Phase, 470 A, 200 V to 480 V, 250 kW at 400 V, Spring Terminal
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Motor Starters
- SVHC: To Be Advised
- No. of Poles: -
- Power Rating: 400kW
- No. of Phases: Three Phase
- Product Range: SIRIUS 3RW55
- Current Rating: 814A
- IP / NEMA Rating: IP00
- Motor Starter Type: Soft Starter
- Supply Voltage Max: 480VAC
- Supply Voltage Min: 200VAC
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 8508.6 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RW5547-2HF14** **Data sheet** SIRIUS soft starter 200-480 V 470 A, 110-250 V AC, spring-type terminals Failsafe |Siemens<br>EcoTech|SIRIUS soft starter 200-480 V 470 A, 110-250 V AC, spring-type terminals Fail-<br>safe| |---|---| |**product brand name**|SIRIUS| |**product category**|Hybrid switchingdevices| |**product designation**|Failsafe soft starters| |**product type designation**|3RW55| |**manufacturer's article number**|| |● of high feature HMI module usable|3RW5980-0HF00| |● of communication module PROFINET standard usable|3RW5980-0CS00| |● of communication module PROFINET high-feature usable|3RW5950-0CH00| |● of communication module PROFIBUS usable|3RW5980-0CP00| |● of communication module Modbus TCP usable|3RW5980-0CT00| |● of communication module Modbus RTU usable|3RW5980-0CR00| |● of communication module Ethernet/IP|3RW5980-0CE00| |● of circuit breaker usable at 400 V|3VA2450-7MN32-0AA0; Type of coordination 1, Iq=65 kA, CLASS 10| |● of circuit breaker usable at 500 V|3VA2450-7MN32-0AA0; Type of coordination 1, Iq=65 kA, CLASS 10| |● of circuit breaker usable at 400 V at inside-delta circuit|3VA2510-6HN32-0AA0; Type of coordination 1, Iq=65 kA, CLASS 10| |● of circuit breaker usable at 500 V at inside-delta circuit|3VA2510-6HN32-0AA0; Type of coordination 1, Iq=65 kA, CLASS 10| |● of thegG fuse usable upto 690 V|2x3NA3365-6; Type of coordination 1, Iq= 65 kA| |● of thegG fuse usable at inside-delta circuit upto 500 V|2x3NA3365-6; Type of coordination 1, Iq= 65 kA| |● of full range R fuse link for semiconductor protection<br>usable upto 690 V|3NE1436-2; Type of coordination 2, Iq=65 kA| |● of back-up R fuse link for semiconductor protection<br>usable upto 690 V|3NE3340-8; Type of coordination 2, Iq=65 kA| |● of the redundant contactor for applications > SIL 1<br>accordingto EN 62061|3TF69| |● of the redundant contactor for applications > SIL 1 at<br>inside-delta circuit accordingto EN 62061|3TF69| |**General technical data**|| |**starting voltage [%]**|20 ... 100 %| |**stopping voltage [%]**|50 %; non-adjustable| |**start-up ramp time of soft starter**|0 ... 360 s| |**ramp-down time of soft starter**|0 ... 360 s| |**start torque[%]**|10 ... 100 %| |**stopping torque[%]**|10 ... 100 %| |**torque limitation[%]**|20 ... 200 %| |**current limiting value[%] adjustable**|125 ... 800 %| |**breakaway voltage [%] adjustable**|40 ... 100 %| |**breakaway time adjustable**|0 ... 2 s| |**number ofparameter sets**|3| |**accuracy class**|5(based on IEC 61557-12)| |**certificate of suitability**|| |● CE marking|Yes| |● UL approval|Yes| |● CSA approval|Yes| |**product component**|| |● HMI-High Feature|Yes| |● is supported HMI-High Feature|Yes| |**product feature integrated bypass contact system**|Yes| |**number of controlled phases**|3| Subject to change without notice © Copyright Siemens 3RW55472HF14 Page 1/7 5/30/2026 |**current unbalance limiting value[%]**|10 ... 60 %| |---|---| |**ground-fault monitoring limiting value[%]**|10 ... 95 %| |**buffering time in the event ofpower failure**|| |● for main current circuit|100 ms| |● for control circuit|100 ms| |**idle time adjustable**|0 ... 255 s| |**insulation voltage rated value**|480 V| |**degree ofpollution**|3, acc. to IEC 60947-4-2| |**impulse voltage rated value**|6 kV| |**blocking voltage of the thyristor maximum**|1 400 V| |**service factor**|1.15| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● between main and auxiliarycircuit|480 V; does not applyfor thermistor connection| |**shock resistance**|15g/ 11 ms, from 6g/ 11 ms withpotential contact lifting| |**vibration resistance**|15 mm upto 6 Hz; 2gupto 500 Hz| |**recovery time after overload trip adjustable**|60 ... 1 800 s| |utilization categoryaccordingto IEC 60947-4-2|AC 53a| |**reference code according to IEC 81346-2**|Q| |**Substance Prohibitance(day/month/year)**|11/22/2019| |**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1<br>6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1<br>Dibutylbis(pentane-2,4-dionato-O,O')tin CAS-No. 22673-19-4<br>Lead titanium trioxide CAS-No. 12060-00-3| |**Net Weight**|12.211 kg| |**product function**|| |● ramp-up (soft starting)|Yes| |● soft stopping|Yes| |● breakaway pulse|Yes| |● adjustable current limitation|Yes| |● creepspeed in both directions of rotation|Yes| |●pumpstop|Yes| |● DC braking|Yes| |● motor heating|Yes| |● min/maxpointer|Yes| |● trace function|Yes| |● intrinsic deviceprotection|Yes| |● motor overload protection|Yes; Full motor protection (thermistor motor protection and electronic motor<br>overload protection) / When using the motor overload protection according to<br>ATEX, an upstream contactor is required in inside-delta circuit.| |● evaluation of thermistor motorprotection|Yes; Type A PTC or Klixon / Thermoclick| |● inside-delta circuit|Yes| |● auto-RESET|Yes| |● manual RESET|Yes| |● remote reset|Yes| |● communication function|Yes| |● operatingmeasured value display|Yes| |● event list|Yes| |● error logbook|Yes| |● via softwareparameterizable|Yes| |● via software configurable|Yes| |● screw terminal|No| |● spring-loaded terminal|Yes| |**● PROFIenergy**|Yes; in connection with the PROFINET Standard and PROFINET High-Feature<br>communication modules| |**● firmware update**|Yes| |**● removable terminal for control circuit**|Yes| |● voltage ramp|Yes| Subject to change without notice © Copyright Siemens 3RW55472HF14 Page 2/7 5/30/2026 |● torque control|Yes| |---|---| |● combined braking|Yes| |● analogoutput|Yes; 4 ... 20 mA(default)/ 0 ... 10 V| |●programmable control inputs/outputs|Yes| |● condition monitoring|Yes| |● automaticparameterisation|Yes| |● application wizards|Yes| |● alternative stoppingmode|Yes| |● emergencyoperation mode|Yes| |● reversingoperation|Yes| |● soft startingat heavystartingconditions|Yes| |**Power Electronics**|| |**operational current**|| |● at 40 °C rated value|470 A| |● at 40 °C rated value minimum|94 A| |● at 50 °C rated value|416 A| |● at 60 °C rated value|380 A| |**operational current at inside-delta circuit**|| |● at 40 °C rated value|814 A| |● at 50 °C rated value|721 A| |● at 60 °C rated value|658 A| |**operating voltage**|| |● rated value|200 ... 480 V| |● at inside-delta circuit rated value|200 ... 480 V| |**relative negative tolerance of the operating voltage**|-15 %| |**relativepositive tolerance of the operating voltage**|10 %| |**relative negative tolerance of the operating voltage at**<br>**inside-delta circuit**|-15 %| |**relative positive tolerance of the operating voltage at**<br>**inside-delta circuit**|10 %| |**operating power for 3-phase motors**|| |● at 230 V at 40 °C rated value|132 kW| |● at 230 V at inside-delta circuit at 40 °C rated value|250 kW| |● at 400 V at 40 °C rated value|250 kW| |● at 400 V at inside-delta circuit at 40 °C rated value|400 kW| |**Operating frequency 1 rated value**|50 Hz| |**Operating frequency 2 rated value**|60 Hz| |**relative negative tolerance of the operating frequency**|-10 %| |**relativepositive tolerance of the operating frequency**|10 %| |**minimum load[%]**|10 %; Relative to set Ie| |**power loss[W] for rated value of the current at AC**|| |● at 40 °C after startup|141 W| |● at 50 °C after startup|125 W| |● at 60 °C after startup|114 W| |**power loss[W] at AC at current limitation 350 %**|| |● at 40 °C duringstartup|7 651 W| |● at 50 °C duringstartup|6 400 W| |● at 60 °C duringstartup|5 620 W| |**type of the motor protection**|Electronic, trippingin the event of thermal overload of the motor| |**Control circuit/ Control**|| |**type of voltage of the control supply voltage**|AC| |**control supply voltage at AC**|| |● at 50 Hz|110 ... 250 V| |● at 60 Hz|110 ... 250 V| |**relative negative tolerance of the control supply voltage at**<br>**AC at 50 Hz**|-15 %| |**relative positive tolerance of the control supply voltage at**<br>**AC at 50 Hz**|10 %| |**relative negative tolerance of the control supply voltage at**<br>**AC at 60 Hz**|-15 %| Subject to change without notice © Copyright Siemens 3RW55472HF14 Page 3/7 5/30/2026 |**relative positive tolerance of the control supply voltage at**<br>**AC at 60 Hz**|10 %| |---|---| |**control supply voltage frequency**|50 ... 60 Hz| |**relative negative tolerance of the control supply voltage**<br>**frequency**|-10 %| |**relative positive tolerance of the control supply voltage**<br>**frequency**|10 %| |**control supply current in standby mode rated value**|100 mA| |**holding current in bypass operation rated value**|150 mA| |**inrush current by closing the bypass contacts maximum**|0.87 A| |inrush current peak at application of control supply voltage<br>maximum|43 A| |duration of inrush current peak at application of control supply<br>voltage|1.6 ms| |**design of the overvoltage protection**|Varistor| |**design of short-circuit protection for control circuit**|4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit<br>breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of<br>scope of supply| |**Inputs/ Outputs**|| |**number of digital inputs**|4| |● with fail-safe|1| |●parameterizable|4| ||| |**● number of digital outputs**|3| |● Number of digital outputs with fail-safe|1| |● number of digital outputsparameterizable|2| |● number of digital outputs notparameterizable|1| |**digital output version**|2 normally-open contacts (NO) / 1 normally-closed contact (NC) / 1 changeover<br>contact(CO)| |**number of analog outputs**|1| |**switching capacity current of the relay outputs**|| |● at AC-15 at 250 V rated value|3 A| |● at DC-13 at 24 V rated value|1 A| |**Response times**|| |OFF-delay time with safety-related request when switched off<br>via control inputs maximum|100 ms| |**Installation/ mounting/ dimensions**|| |**mounting position**|Vertical(can be rotated +/- 90° and tilted forward or backward +/- 22.5°)| |**fastening method**|screw fixing| |**height**|393 mm| |**width**|210 mm| |**depth**|203 mm| |required spacingwith side-by-side mounting|| |● forwards|10 mm| |● backwards|0 mm| |● upwards|100 mm| |● downwards|75 mm| |● at the side|5 mm| |**weight without packaging**|10.9 kg| |**Connections/ Terminals**|| |**type of electrical connection**|| |● for main current circuit|busbar connection| |● for control circuit|spring-loaded terminals| |**width of connection bar maximum**|45 mm| |**wire length for thermistor connection**|| |● with conductor cross-section = 0.5 mm² maximum|50 m| |● with conductor cross-section = 1.5 mm² maximum|150 m| |● with conductor cross-section = 2.5 mm² maximum|250 m| |**type of connectable conductor cross-sections**|| |● for DIN cable lugfor main contacts stranded|2x(50 ... 240 mm²)| |● for DIN cable lug for main contacts finely stranded|2x (70 ... 240 mm²)| Subject to change without notice © Copyright Siemens 3RW55472HF14 Page 4/7 5/30/2026 |**type of connectable conductor cross-sections**|| |---|---| |● for control circuit solid|2x(0.25 ... 1.5 mm²)| |● for control circuit finelystranded with core endprocessing|2x(0.25 ... 1.5 mm²)| |● for AWG cables for control circuit solid|2x(24 ... 16)| |● for AWG cables for control circuit finely stranded with<br>core endprocessing|2x (24 ... 16)| |**wire length**|| |● between soft starter and motor maximum|800 m| |● at the digital inputs at DC maximum|1 000 m| |**tightening torque**|| |● for main contacts with screw-type terminals|14 ... 24 N·m| |● for auxiliary and control contacts with screw-type<br>terminals|0.8 ... 1.2 N·m| |**tightening torque[lbf·in]**|| |● for main contacts with screw-type terminals|124 ... 210 lbf·in| |● for auxiliary and control contacts with screw-type<br>terminals|7 ... 10.3 lbf·in| |**Ambient conditions**|| |installation altitude at height above sea level maximum|2 000 m| |**ambient temperature**|| |● duringoperation|-25 ... +60 °C; Please observe deratingat temperatures of 40 °C or above| |● duringstorage and transport|-40 ... +80 °C| |**environmental category**|| |● during operation according to IEC 60721|3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2<br>(sand must notget into the devices), 3M6| |● during storage according to IEC 60721|1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get<br>inside the devices), 1M4| |● duringtransport accordingto IEC 60721|2K2, 2C1, 2S1, 2M2(max. fall height 0.3 m)| |**Electromagnetic compatibility**|| |**EMC emitted interference**|acc. to IEC 60947-4-2: Class A| |**Communication/ Protocol**|| |**communication module is supported**|| |● PROFINET standard|Yes| |● PROFINET high-feature|Yes| |● EtherNet/IP|Yes| |● Modbus RTU|Yes| |● Modbus TCP|Yes| |● PROFIBUS|Yes| |**UL/CSA ratings**|| |**manufacturer's article number**|| |**● of the fuse**|| |— usable for Standard Faults up to 575/600 V<br>accordingto UL|Type: Class J / L, max. 1600 A; Iq = 30 kA| |— usable for High Faults up to 575/600 V according to<br>UL|Type: Class J / L, max. 1200 A; Iq = 100 kA| |— usable for Standard Faults at inside-delta circuit up<br>to 575/600 V accordingto UL|Type: Class J / L, max. 1600 A; Iq = 30 kA| |— usable for High Faults at inside-delta circuit up to<br>575/600 V accordingto UL|Type: Class J / L, max. 1200 A; Iq = 100 kA| |**operating power[hp] for 3-phase motors**|| |● at 200/208 V at 50 °C rated value|150 hp| |● at 220/230 V at 50 °C rated value|150 hp| |● at 460/480 V at 50 °C rated value|350 hp| |● at 200/208 V at inside-delta circuit at 50 °C rated value|250 hp| |● at 220/230 V at inside-delta circuit at 50 °C rated value|250 hp| |● at 460/480 V at inside-delta circuit at 50 °C rated value|600 hp| |**contact rating of auxiliary contacts according to UL**|R300-B300| |**Safety related data**|| |product function suitable for safetyfunction|Yes| |**suitability for use**|| |● safety-related switching on|No| Subject to change without notice © Copyright Siemens 3RW55472HF14 Page 5/7 5/30/2026 |● safety-related switchingOFF|Yes| |---|---| |**safe state**|Open load circuit| |**function test interval maximum**|1 a| |**diagnostics test interval by internal test function maximum**|1 000 s| |**stop category according to IEC 60204-1**|0| |**B10d value**<br>~~CO~~<br>~~Eee~~|648 000<br>~~Eee~~| |**average diagnostic coverage level(DCavg)**<br>~~CO~~<br>~~Eee~~|90 %<br>~~Eee~~| |**MTTFd**<br>~~CO~~|39 a| |IEC 62061|| |**Safety Integrity Level(SIL) according to IEC 62061**|SIL 1| |PFHD with high demand rate accordingto IEC 62061<br>~~a~~|1E-6 1/h<br>~~a~~| |ISO 13849<br>~~a~~|| |**performance level(PL) according to ISO 13849-1**<br>~~a~~<br>~~Eee~~|PL c<br>~~a~~<br>~~Eee~~| |**category according to ISO 13849-1**<br>~~Eee~~|2<br>~~Eee~~| |IEC 61508<br>~~Eee~~|| |**Safety Integrity Level(SIL)**<br>~~Eee~~<br>~~————~~|~~Eee~~<br>~~————~~| |● accordingto IEC 61508<br>~~————~~|SIL 1<br>~~————~~| |**safety device type according to IEC 61508-2**<br>~~————~~|Type B<br>~~————~~| |**PFHD with high demand rate according to IEC 61508**|1E-6 1/h| |PFDavgwith low demand rate accordingto IEC 61508|0.09| |**Safe failure fraction(SFF)**<br>~~OO~~<br>~~EEE~~|60 %<br>~~EEE~~| |hardware fault tolerance accordingto IEC 61508<br>~~OO~~<br>~~EEE~~|0<br>~~EEE~~| |T1 value of service life accordingto IEC 61508<br>~~OO~~|20 a| |Electrical Safety|| |**protection class IP on the front according to IEC 60529**|IP00; IP20 with cover| |**touch protection on the front according to IEC 60529**|finger-safe, for vertical contact from the front with cover| |**ATEX**<br>~~ee~~|| |**Safety Integrity Level (SIL) according to IEC 61508 relating**<br>**to ATEX**<br>~~ee~~|SIL 1<br>~~ee~~| |**PFHD with high demand rate according to IEC 61508**<br>**relating to ATEX**<br>~~_——=&E~~<br>~~—E~~|5E-7 1/h<br>~~_——=&E~~<br>~~ll~~<br>~~tt te~~| |**PFDavg with low demand rate according to IEC 61508**<br>**relating to ATEX**<br>~~_——=&E~~<br>~~—E~~<br>~~<_<~~|0.008<br>~~_——=&E~~<br>~~ll~~<br>~~tt te~~<br>~~<_<&##8§€=©=—lLr~~| |**hardware fault tolerance according to IEC 61508 relating to**<br>**ATEX**<br>~~—E~~<br>~~<_<~~<br>~~_———=&E_~~|0<br>~~ll~~<br>~~tt te~~<br>~~<_<&##8§€=©=—lLr~~<br>~~_———=&E_~~<br>~~lll~~<br>~~tt~~<br>~~tits~~| |**T1 value for proof test interval or service life according to**<br>**IEC 61508 relating to ATEX**<br>~~—E~~<br>~~<_<~~<br>~~_———=&E_~~|3 a<br>~~ll~~<br>~~tt te~~<br>~~<_<~~<br>~~_———=&E_~~<br>~~lll~~<br>~~tt~~<br>~~tits~~| |**certificate of suitability**|~~lll~~<br>~~tt~~<br>~~tits~~| |● ATEX|Yes| |● IECEx|Yes| |● accordingto ATEX directive 2014/34/EU<br>~~———EE—=—_~~|BVS 18 ATEX F 003 X<br>~~———EE—=—_~~<br>~~££~~<br>~~#&#&#&§=§888§«§=—Ch~~| |**type of protection according to ATEX directive 2014/34/EU**<br>~~———EE—=—_~~|II (2)G [Ex eb Gb] [Ex db Gb] [Ex pxb Gb], II (2)D [Ex tb Db] [Ex pxb Db], I (M2)<br>[Ex db Mb]<br>~~———EE—=—_~~<br>~~££~~<br>~~#&#&#&§=§888§«§=—Ch~~| |**Approvals Certificates**<br>~~££~~<br>~~#&#&#&§=§ 8 88§«§=—Ch~~|| |Environmental Product Declaration<br>● global warming potential [CO2 eq] / during manufacturing<br>95.3 kg<br>● global warming potential [CO2 eq] / during sales<br>2.8 kg<br>● global warming potential [CO2 eq] / during operation<br>756 kg<br>● global warming potential [CO2 eq] / after end of life<br>-21 kg<br>● global warming potential [CO2 eq] / total<br>833 kg<br>**Environment**<br>**General Product Approval**|| **General Product Approval** **EMV** **For use in hazardous locations** Subject to change without notice © Copyright Siemens 3RW55472HF14 Page 6/7 5/30/2026 |**Functional Saftey**<br>**Test Certificates**<br>**Maritime application**| |---| |Type Examination Cer-<br>Type Test Certific-| |tificate<br>ates/Test Report| |**Maritime application**<br>**other**| |Confirmation<br>Confirmation<br>**Further information**<br>>~~ee~~| |**Information on the packaging**| |https://support.industry.siemens.com/cs/ww/en/view/109813875| |**Information for data generation and storage**| |https://support.industry.siemens.com/cs/ww/en/view/109995012| |**Information- and Downloadcenter (Catalogs, Brochures,…)**| |https://www.siemens.com/ic10| |**Industry Mall (Online ordering system)**| |https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RW5547-2HF14| |**Service&Support (Manuals, Certificates, Characteristics, FAQs,...)**| |https://support.industry.siemens.com/cs/ww/en/ps/3RW5547-2HF14| |**Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)**| |https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RW5547-2HF14&lang=en| |**Cax online generator**| |https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RW5547-2HF14| |**Characteristic curves**| |https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no>| |**Characteristic: Tripping characteristics, I²t, Let-through current**| |https://support.industry.siemens.com/cs/ww/en/ps/3RW5547-2HF14/char| |**Characteristic: Installation altitude**| |https://www.automation.siemens.com/bilddb/index.aspx?gridview=view2&objkey=G_NSB0_XX_01704&showdetail=true&view=Search| |**Simulation Tool for Soft Starters (STS)**| |https://support.industry.siemens.com/cs/ww/en/view/101494917| **last modified:** 9/5/2025 Subject to change without notice © Copyright Siemens 3RW55472HF14 Page 7/7 5/30/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →