Image not available
Illustrative purposes only
3RW5546-6HF14
Soft Starter, 3RW Series, Three Phase, 370 A, 200 V to 480 V, 200 kW at 400 V, Screw
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Motor Starters
- SVHC: To Be Advised
- No. of Poles: -
- Power Rating: 355kW
- No. of Phases: Three Phase
- Product Range: SIRIUS 3RW55
- Current Rating: 641A
- IP / NEMA Rating: IP00
- Motor Starter Type: Soft Starter
- Supply Voltage Max: 480VAC
- Supply Voltage Min: 200VAC
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 7221.0 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RW5546-6HF14** **Data sheet** SIRIUS soft starter 200-480 V 370 A, 110-250 V AC, Screw terminals Fail-safe |SIRIUS soft starter 200-480 V 370 A, 110-250 V AC, Screw terminals Fail-safe<br>**product brand name**<br>SIRIUS<br>**product category**<br>Hybrid switchingdevices<br>**product designation**<br>Failsafe soft starters<br>**product type designation**<br>3RW55<br>**manufacturer's article number**<br>● of high feature HMI module usable<br>3RW5980-0HF00<br>● of communication module PROFINET standard usable<br>3RW5980-0CS00<br>● of communication module PROFINET high-feature usable<br>3RW5950-0CH00<br>● of communication module PROFIBUS usable<br>3RW5980-0CP00<br>● of communication module Modbus TCP usable<br>3RW5980-0CT00<br>● of communication module Modbus RTU usable<br>3RW5980-0CR00<br>● of communication module Ethernet/IP<br>3RW5980-0CE00<br>● of circuit breaker usable at 400 V<br>3VA2440-7MN32-0AA0; Type of coordination 1, Iq=65 kA, CLASS 10<br>● of circuit breaker usable at 500 V<br>3VA2440-7MN32-0AA0; Type of coordination 1, Iq=65 kA, CLASS 10<br>● of circuit breaker usable at 400 V at inside-delta circuit<br>3VA2580-6HN32-0AA0; Type of coordination 1, Iq=65 kA, CLASS 10<br>● of circuit breaker usable at 500 V at inside-delta circuit<br>3VA2580-6HN32-0AA0; Type of coordination 1, Iq=65 kA, CLASS 10<br>● of thegG fuse usable upto 690 V<br>2x3NA3365-6; Type of coordination 1, Iq= 65 kA<br>● of thegG fuse usable at inside-delta circuit upto 500 V<br>2x3NA3365-6; Type of coordination 1, Iq= 65 kA<br>● of full range R fuse link for semiconductor protection<br>usable upto 690 V<br>3NE1334-2; Type of coordination 2, Iq=65 kA<br>● of back-up R fuse link for semiconductor protection<br>usable upto 690 V<br>3NE3340-8; Type of coordination 2, Iq=65 kA<br>● of the redundant contactor for applications > SIL 1<br>accordingto EN 62061<br>3TF68<br>● of the redundant contactor for applications > SIL 1 at<br>inside-delta circuit accordingto EN 62061<br>3TF68<br>● of the redundant contactor for applications > SIL 1<br>accordingto EN ISO 13849-1<br>3TF69<br>● of the redundant contactor for applications > SIL 1 at<br>inside-delta circuit accordingto EN ISO 13849-1<br>3TF69<br>**General technical data**<br>**starting voltage [%]**<br>20 ... 100 %<br>**stopping voltage [%]**<br>50 %; non-adjustable<br>**start-up ramp time of soft starter**<br>0 ... 360 s<br>**ramp-down time of soft starter**<br>0 ... 360 s<br>**start torque[%]**<br>10 ... 100 %<br>**stopping torque[%]**<br>10 ... 100 %<br>**torque limitation[%]**<br>20 ... 200 %<br>**current limiting value[%] adjustable**<br>125 ... 800 %<br>**breakaway voltage [%] adjustable**<br>40 ... 100 %<br>**breakaway time adjustable**<br>0 ... 2 s<br>**number ofparameter sets**<br>3<br>**accuracy class**<br>5(based on IEC 61557-12)<br>**certificate of suitability**<br>● CE marking<br>Yes<br>● UL approval<br>Yes<br>● CSA approval<br>Yes<br>**product component**<br>● HMI-High Feature<br>Yes<br>● is supported HMI-High Feature<br>Yes<br>Siemens<br>EcoTech|SIRIUS soft starter 200-480 V 370 A, 110-250 V AC, Screw terminals Fail-safe|| |---|---|---| ||SIRIUS|| ||Hybrid switchingdevices|| ||Failsafe soft starters|| ||3RW55|| |||| ||3RW5980-0HF00|| ||3RW5980-0CS00|| ||3RW5950-0CH00|| ||3RW5980-0CP00|| ||3RW5980-0CT00|| ||3RW5980-0CR00|| ||3RW5980-0CE00|| ||3VA2440-7MN32-0AA0; Type of coordination 1, Iq=65 kA, CLASS 10|| ||3VA2440-7MN32-0AA0; Type of coordination 1, Iq=65 kA, CLASS 10|| ||3VA2580-6HN32-0AA0; Type of coordination 1, Iq=65 kA, CLASS 10|| ||3VA2580-6HN32-0AA0; Type of coordination 1, Iq=65 kA, CLASS 10|| ||2x3NA3365-6; Type of coordination 1, Iq= 65 kA|| ||2x3NA3365-6; Type of coordination 1, Iq= 65 kA|| ||3NE1334-2; Type of coordination 2, Iq=65 kA|| ||3NE3340-8; Type of coordination 2, Iq=65 kA|| ||3TF68|| ||3TF68|| ||3TF69|| ||3TF69|| ||20 ... 100 %|| ||50 %; non-adjustable|| ||0 ... 360 s|| ||0 ... 360 s|| ||10 ... 100 %|| ||10 ... 100 %|| ||20 ... 200 %|| ||125 ... 800 %|| ||40 ... 100 %|| ||0 ... 2 s|| ||3|| ||5(based on IEC 61557-12)|| |||| ||Yes|| ||Yes|| ||Yes|| |||| ||Yes|| ||Yes|| Subject to change without notice © Copyright Siemens 3RW55466HF14 Page 1/7 5/30/2026 |**product feature integrated bypass contact system**|Yes| |---|---| |**number of controlledphases**|3| |**current unbalance limiting value[%]**|10 ... 60 %| |**ground-fault monitoring limiting value[%]**|10 ... 95 %| |**buffering time in the event ofpower failure**|| |● for main current circuit|100 ms| |● for control circuit|100 ms| |**idle time adjustable**|0 ... 255 s| |**insulation voltage rated value**|480 V| |**degree ofpollution**|3, acc. to IEC 60947-4-2| |**impulse voltage rated value**|6 kV| |**blocking voltage of the thyristor maximum**|1 400 V| |**service factor**|1.15| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● between main and auxiliarycircuit|480 V; does not applyfor thermistor connection| |**shock resistance**|15g/ 11 ms, from 6g/ 11 ms withpotential contact lifting| |**vibration resistance**|15 mm upto 6 Hz; 2gupto 500 Hz| |**recovery time after overload trip adjustable**|60 ... 1 800 s| |utilization categoryaccordingto IEC 60947-4-2|AC 53a| |**reference code according to IEC 81346-2**|Q| |**Substance Prohibitance(day/month/year)**|11/22/2019| |**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1<br>6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1<br>Dibutylbis(pentane-2,4-dionato-O,O')tin CAS-No. 22673-19-4<br>Lead titanium trioxide CAS-No. 12060-00-3| |**Net Weight**|12.258 kg| |**product function**|| |● ramp-up (soft starting)|Yes| |● soft stopping|Yes| |● breakaway pulse|Yes| |● adjustable current limitation|Yes| |● creepspeed in both directions of rotation|Yes| |●pumpstop|Yes| |● DC braking|Yes| |● motor heating|Yes| |● min/maxpointer|Yes| |● trace function|Yes| |● intrinsic deviceprotection|Yes| |● motor overload protection|Yes; Full motor protection (thermistor motor protection and electronic motor<br>overload protection) / When using the motor overload protection according to<br>ATEX, an upstream contactor is required in inside-delta circuit.| |● evaluation of thermistor motorprotection|Yes; Type A PTC or Klixon / Thermoclick| |● inside-delta circuit|Yes| |● auto-RESET|Yes| |● manual RESET|Yes| |● remote reset|Yes| |● communication function|Yes| |● operatingmeasured value display|Yes| |● event list|Yes| |● error logbook|Yes| |● via softwareparameterizable|Yes| |● via software configurable|Yes| |● screw terminal|Yes| |● spring-loaded terminal|No| |**● PROFIenergy**|Yes; in connection with the PROFINET Standard and PROFINET High-Feature<br>communication modules| |**● firmware update**|Yes| Subject to change without notice © Copyright Siemens 3RW55466HF14 Page 2/7 5/30/2026 |**● removable terminal for control circuit**|Yes| |---|---| |● voltage ramp|Yes| |● torque control|Yes| |● combined braking|Yes| |● analogoutput|Yes; 4 ... 20 mA(default)/ 0 ... 10 V| |●programmable control inputs/outputs|Yes| |● condition monitoring|Yes| |● automaticparameterisation|Yes| |● application wizards|Yes| |● alternative stoppingmode|Yes| |● emergencyoperation mode|Yes| |● reversingoperation|Yes| |● soft startingat heavystartingconditions|Yes| |**Power Electronics**|| |**operational current**|| |● at 40 °C rated value|370 A| |● at 40 °C rated value minimum|74 A| |● at 50 °C rated value|328 A| |● at 60 °C rated value|300 A| |**operational current at inside-delta circuit**|| |● at 40 °C rated value|641 A| |● at 50 °C rated value|568 A| |● at 60 °C rated value|519 A| |**operating voltage**|| |● rated value|200 ... 480 V| |● at inside-delta circuit rated value|200 ... 480 V| |**relative negative tolerance of the operating voltage**|-15 %| |**relativepositive tolerance of the operating voltage**|10 %| |**relative negative tolerance of the operating voltage at**<br>**inside-delta circuit**|-15 %| |**relative positive tolerance of the operating voltage at**<br>**inside-delta circuit**|10 %| |**operating power for 3-phase motors**|| |● at 230 V at 40 °C rated value|110 kW| |● at 230 V at inside-delta circuit at 40 °C rated value|200 kW| |● at 400 V at 40 °C rated value|200 kW| |● at 400 V at inside-delta circuit at 40 °C rated value|355 kW| |**Operating frequency 1 rated value**|50 Hz| |**Operating frequency 2 rated value**|60 Hz| |**relative negative tolerance of the operating frequency**|-10 %| |**relativepositive tolerance of the operating frequency**|10 %| |**minimum load[%]**|10 %; Relative to set Ie| |**power loss[W] for rated value of the current at AC**|| |● at 40 °C after startup|111 W| |● at 50 °C after startup|98 W| |● at 60 °C after startup|90 W| |**power loss[W] at AC at current limitation 350 %**|| |● at 40 °C duringstartup|5 563 W| |● at 50 °C duringstartup|4 694 W| |● at 60 °C duringstartup|4 145 W| |**type of the motor protection**|Electronic, trippingin the event of thermal overload of the motor| |**Control circuit/ Control**|| |**type of voltage of the control supply voltage**|AC| |**control supply voltage at AC**|| |● at 50 Hz|110 ... 250 V| |● at 60 Hz|110 ... 250 V| |**relative negative tolerance of the control supply voltage at**<br>**AC at 50 Hz**|-15 %| |**relative positive tolerance of the control supply voltage at**<br>**AC at 50 Hz**|10 %| Subject to change without notice © Copyright Siemens 3RW55466HF14 Page 3/7 5/30/2026 ||**relative negative tolerance of the control supply voltage at**<br>**AC at 60 Hz**|-15 %|| |---|---|---|---| ||**relative positive tolerance of the control supply voltage at**<br>**AC at 60 Hz**|10 %|| ||**control supply voltage frequency**|50 ... 60 Hz|| ||**relative negative tolerance of the control supply voltage**<br>**frequency**|-10 %|| ||**relative positive tolerance of the control supply voltage**<br>**frequency**|10 %|| ||**control supply current in standby mode rated value**|100 mA|| ||**holding current in bypass operation rated value**|150 mA|| ||**inrush current by closing the bypass contacts maximum**|0.87 A|| ||inrush current peak at application of control supply voltage<br>maximum|43 A|| ||duration of inrush current peak at application of control supply<br>voltage|1.6 ms|| ||**design of the overvoltage protection**|Varistor|| ||**design of short-circuit protection for control circuit**|4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit<br>breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of<br>scope of supply|| ||**Inputs/ Outputs**||| ||**number of digital inputs**|4|| ||● with fail-safe|1|| ||●parameterizable|4|| ||||| ||**● number of digital outputs**|3|| ||● Number of digital outputs with fail-safe|1|| ||● number of digital outputsparameterizable|2|| ||● number of digital outputs notparameterizable|1|| ||**digital output version**|2 normally-open contacts (NO) / 1 normally-closed contact (NC) / 1 changeover<br>contact(CO)|| ||**number of analog outputs**|1|| ||**switching capacity current of the relay outputs**||| ||● at AC-15 at 250 V rated value|3 A|| ||● at DC-13 at 24 V rated value|1 A|| ||**Response times**||| ||OFF-delay time with safety-related request when switched off<br>via control inputs maximum|100 ms|| ||**Installation/ mounting/ dimensions**||| ||**mounting position**|Vertical(can be rotated +/- 90° and tilted forward or backward +/- 22.5°)|| ||**fastening method**|screw fixing|| ||**height**|393 mm|| ||**width**|210 mm|| ||**depth**|203 mm|| ||required spacingwith side-by-side mounting||| ||● forwards|10 mm|| ||● backwards|0 mm|| ||● upwards|100 mm|| ||● downwards|75 mm|| ||● at the side|5 mm|| ||**weight without packaging**|10.9 kg|| ||**Connections/ Terminals**||| ||**type of electrical connection**||| ||● for main current circuit|busbar connection|| ||● for control circuit|screw-type terminals|| ||**width of connection bar maximum**|45 mm|| ||**wire length for thermistor connection**||| ||● with conductor cross-section = 0.5 mm² maximum|50 m|| ||● with conductor cross-section = 1.5 mm² maximum|150 m|| ||● with conductor cross-section = 2.5 mm² maximum|250 m|| ||**type of connectable conductor cross-sections**||| ||● for DIN cable lug for main contacts stranded|2x (50 ... 240 mm²)|| Subject to change without notice © Copyright Siemens 3RW55466HF14 Page 4/7 5/30/2026 |● for DIN cable lugfor main contacts finelystranded|2x(70 ... 240 mm²)| |---|---| |**type of connectable conductor cross-sections**|| |● for control circuit solid|1x(0.5 ... 4.0 mm²), 2x(0.5 ... 2.5 mm²)| |● for control circuit finelystranded with core endprocessing|1x(0.5 ... 2.5 mm²), 2x(0.5 ... 1.5 mm²)| |● for AWG cables for control circuit solid|1x(20 ... 12), 2x(20 ... 14)| |**wire length**|| |● between soft starter and motor maximum|800 m| |● at the digital inputs at DC maximum|1 000 m| |**tightening torque**|| |● for main contacts with screw-type terminals|14 ... 24 N·m| |● for auxiliary and control contacts with screw-type<br>terminals|0.8 ... 1.2 N·m| |**tightening torque[lbf·in]**|| |● for main contacts with screw-type terminals|124 ... 210 lbf·in| |● for auxiliary and control contacts with screw-type<br>terminals|7 ... 10.3 lbf·in| |**Ambient conditions**|| |installation altitude at height above sea level maximum|2 000 m| |**ambient temperature**|| |● duringoperation|-25 ... +60 °C; Please observe deratingat temperatures of 40 °C or above| |● duringstorage and transport|-40 ... +80 °C| |**environmental category**|| |● during operation according to IEC 60721|3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2<br>(sand must notget into the devices), 3M6| |● during storage according to IEC 60721|1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get<br>inside the devices), 1M4| |● duringtransport accordingto IEC 60721|2K2, 2C1, 2S1, 2M2(max. fall height 0.3 m)| |**Electromagnetic compatibility**|| |**EMC emitted interference**|acc. to IEC 60947-4-2: Class A| |**Communication/ Protocol**|| |**communication module is supported**|| |● PROFINET standard|Yes| |● PROFINET high-feature|Yes| |● EtherNet/IP|Yes| |● Modbus RTU|Yes| |● Modbus TCP|Yes| |● PROFIBUS|Yes| |**UL/CSA ratings**|| |**manufacturer's article number**|| |**● of the fuse**|| |— usable for Standard Faults up to 575/600 V<br>accordingto UL|Type: Class J / L, max. 1200 A; Iq = 18 kA| |— usable for High Faults up to 575/600 V according to<br>UL|Type: Class J / L, max. 1200 A; Iq = 100 kA| |— usable for Standard Faults at inside-delta circuit up<br>to 575/600 V accordingto UL|Type: Class J / L, max. 1200 A; Iq = 18 kA| |— usable for High Faults at inside-delta circuit up to<br>575/600 V accordingto UL|Type: Class J / L, max. 1200 A; Iq = 100 kA| |**operating power[hp] for 3-phase motors**|| |● at 200/208 V at 50 °C rated value|100 hp| |● at 220/230 V at 50 °C rated value|125 hp| |● at 460/480 V at 50 °C rated value|250 hp| |● at 200/208 V at inside-delta circuit at 50 °C rated value|200 hp| |● at 220/230 V at inside-delta circuit at 50 °C rated value|200 hp| |● at 460/480 V at inside-delta circuit at 50 °C rated value|450 hp| |**contact rating of auxiliary contacts according to UL**|R300-B300| |**Safety related data**|| |product function suitable for safetyfunction|Yes| |**suitability for use**|| |● safety-related switchingon|No| |● safety-related switching OFF|Yes| Subject to change without notice © Copyright Siemens 3RW55466HF14 Page 5/7 5/30/2026 |**safe state**|Open load circuit| |---|---| |**function test interval maximum**|1 a| |**diagnostics test interval by internal test function maximum**|1 000 s| |**stop category according to IEC 60204-1**|0| |**B10d value**<br>~~CO~~<br>~~Eee~~|648 000<br>~~Eee~~| |**average diagnostic coverage level(DCavg)**<br>~~CO~~<br>~~Eee~~|90 %<br>~~Eee~~| |**MTTFd**<br>~~CO~~|39 a| |IEC 62061|| |**Safety Integrity Level(SIL) according to IEC 62061**|SIL 1| |PFHD with high demand rate accordingto IEC 62061<br>~~SS~~|1E-6 1/h<br>~~SS~~| |ISO 13849<br>~~SS~~|| |**performance level(PL) according to ISO 13849-1**<br>~~SS~~<br>~~Ee~~|PL c<br>~~SS~~<br>~~Ee~~| |**category according to ISO 13849-1**<br>~~Ee~~|2<br>~~Ee~~| |IEC 61508<br>~~Ee~~|| |**Safety Integrity Level(SIL)**<br>~~Ee~~|~~Ee~~<br>~~re~~| |● accordingto IEC 61508|SIL 1<br>~~re~~| |**safety device type according to IEC 61508-2**|Type B| |**PFHD with high demand rate according to IEC 61508**|1E-6 1/h| |PFDavgwith low demand rate accordingto IEC 61508|0.09| |**Safe failure fraction(SFF)**<br>~~=~~|60 %<br>~~=~~<br>~~==—rt—e—<“<‘“‘“‘“‘SSCSC‘*s~~| |hardware fault tolerance accordingto IEC 61508<br>~~=~~|0<br>~~=~~<br>~~==—rt—e—<“<‘“‘“‘“‘SSCSC‘*s~~| |T1 value of service life accordingto IEC 61508|20 a<br>~~==—rt— e—<“<‘“‘“‘“‘SSCSC‘*s~~| |Electrical Safety|| |**protection class IP on the front according to IEC 60529**|IP00; IP20 with cover| |**touch protection on the front according to IEC 60529**|finger-safe, for vertical contact from the front with cover| |**ATEX**<br>~~Se~~|| |**Safety Integrity Level (SIL) according to IEC 61508 relating**<br>**to ATEX**<br>~~Se~~|SIL 1<br>~~Se~~| |**PFHD with high demand rate according to IEC 61508**<br>**relating to ATEX**<br>~~_—————~~|5E-7 1/h<br>~~_—————~~<br>~~Ll~~<br>~~esis~~| |**PFDavg with low demand rate according to IEC 61508**<br>**relating to ATEX**<br>~~_—————~~<br>~~—=———————~~|0.008<br>~~_—————~~<br>~~Ll~~<br>~~esis~~<br>~~—=———————~~<br>~~ll~~<br>~~ti“rt—Cis~~| |**hardware fault tolerance according to IEC 61508 relating to**<br>**ATEX**<br>~~—=———————~~<br>~~_——OCi———~~|0<br>~~Ll~~<br>~~esis~~<br>~~—=———————~~<br>~~ll~~<br>~~ti“rt—Cis~~<br>~~_——OCi———~~<br>~~ti“Cs~~| |**T1 value for proof test interval or service life according to**<br>**IEC 61508 relating to ATEX**<br>~~_——OCi———~~|3 a<br>~~ll~~<br>~~ti“ rt—Cis~~<br>~~_——OCi———~~<br>~~ti“Cs~~| |**certificate of suitability**|~~ti“ Cs~~| |● ATEX|Yes| |● IECEx|Yes| |● accordingto ATEX directive 2014/34/EU<br>~~———_~~|BVS 18 ATEX F 003 X<br>~~———_~~<br>~~te;~~| |**type of protection according to ATEX directive 2014/34/EU**<br>~~———_~~|II (2)G [Ex eb Gb] [Ex db Gb] [Ex pxb Gb], II (2)D [Ex tb Db] [Ex pxb Db], I (M2)<br>[Ex db Mb]<br>~~———_~~<br>~~te;~~| |**Approvals Certificates**<br>~~te;~~|| |Environmental Product Declaration<br>● global warming potential [CO2 eq] / during manufacturing<br>95.3 kg<br>● global warming potential [CO2 eq] / during sales<br>2.8 kg<br>● global warming potential [CO2 eq] / during operation<br>756 kg<br>● global warming potential [CO2 eq] / after end of life<br>-21 kg<br>● global warming potential [CO2 eq] / total<br>833 kg<br>**Environment**<br>**General Product Approval**|| Subject to change without notice © Copyright Siemens 3RW55466HF14 Page 6/7 5/30/2026 |**Functional Saftey**<br>**Test Certificates**<br>**Maritime application**| |---| |Type Examination Cer-<br>Type Test Certific-| |tificate<br>ates/Test Report| |**Maritime application**<br>**other**| |Confirmation<br>Confirmation<br>**Further information**<br>>~~ee~~| |**Information on the packaging**| |https://support.industry.siemens.com/cs/ww/en/view/109813875| |**Information for data generation and storage**| |https://support.industry.siemens.com/cs/ww/en/view/109995012| |**Information- and Downloadcenter (Catalogs, Brochures,…)**| |https://www.siemens.com/ic10| |**Industry Mall (Online ordering system)**| |https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RW5546-6HF14| |**Service&Support (Manuals, Certificates, Characteristics, FAQs,...)**| |https://support.industry.siemens.com/cs/ww/en/ps/3RW5546-6HF14| |**Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)**| |https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RW5546-6HF14&lang=en| |**Cax online generator**| |https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RW5546-6HF14| |**Characteristic curves**| |https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no>| |**Characteristic: Tripping characteristics, I²t, Let-through current**| |https://support.industry.siemens.com/cs/ww/en/ps/3RW5546-6HF14/char| |**Characteristic: Installation altitude**| |https://www.automation.siemens.com/bilddb/index.aspx?gridview=view2&objkey=G_NSB0_XX_01704&showdetail=true&view=Search| |**Simulation Tool for Soft Starters (STS)**| |https://support.industry.siemens.com/cs/ww/en/view/101494917| **last modified:** 9/5/2025 Subject to change without notice © Copyright Siemens 3RW55466HF14 Page 7/7 5/30/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →