Image not available
Illustrative purposes only
3RW5513-3HA05
Soft Starter, 3RW Series, Three Phase, 13 A, 200 V to 600 V, 5.5 kW at 400 V, Spring Terminal
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Motor Starters
- SVHC: To Be Advised
- No. of Poles: -
- Power Rating: 5.5kW
- No. of Phases: Three Phase
- Product Range: SIRIUS 3RW55
- Current Rating: 13A
- IP / NEMA Rating: IP20
- Motor Starter Type: Soft Starter
- Supply Voltage Max: 600VAC
- Supply Voltage Min: 200VAC
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1061.4 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RW5513-3HA05** **Data sheet** SIRIUS soft starter 200-600 V 13 A, 24 V AC/DC spring-type terminals |**product brand name**|SIRIUS| |---|---| |**product category**|Hybrid switchingdevices| |**product designation**|Soft starter| |**product type designation**|3RW55| |**manufacturer's article number**|| |● of high feature HMI module usable|3RW5980-0HF00| |● of communication module PROFINET standard usable|3RW5980-0CS00| |● of communication module PROFINET high-feature usable|3RW5950-0CH00| |● of communication module PROFIBUS usable|3RW5980-0CP00| |● of communication module Modbus TCP usable|3RW5980-0CT00| |● of communication module Modbus RTU usable|3RW5980-0CR00| |● of communication module Ethernet/IP|3RW5980-0CE00| |● of circuit breaker usable at 400 V|3RV2032-4TA10; Type of coordination 1, Iq=65 kA, CLASS 10| |● of circuit breaker usable at 500 V|3RV2032-4TA10; Type of coordination 1, Iq=18 kA, CLASS 10| |● of circuit breaker usable at 400 V at inside-delta circuit|3RV2032-4DA10; Type of coordination 1, Iq=65 kA, CLASS 10| |● of circuit breaker usable at 500 V at inside-delta circuit|3RV2032-4DA10; Type of coordination 1, Iq=18 kA, CLASS 10| |● of thegG fuse usable upto 690 V|3NA3820-6; Type of coordination 1, Iq=65 kA| |● of thegG fuse usable at inside-delta circuit upto 500 V|3NA3820-6; Type of coordination 1, Iq=65 kA| |● of full range R fuse link for semiconductor protection|3NE1815-0; Type of coordination 2, Iq=65 kA| |usable upto 690 V|| |● of back-up R fuse link for semiconductor protection|3NE8017-1; Type of coordination 2, Iq=65 kA| |usable up to 690 V|| |**General technical data**|| |**starting voltage [%]**|20 ... 100 %| |**stopping voltage [%]**|50 %; non-adjustable| |**start-up ramp time of soft starter**|0 ... 360 s| |**ramp-down time of soft starter**|0 ... 360 s| |**start torque[%]**|10 ... 100 %| |**stopping torque[%]**|10 ... 100 %| |**torque limitation[%]**|20 ... 200 %| |**current limiting value[%] adjustable**|125 ... 800 %| |**breakaway voltage [%] adjustable**|40 ... 100 %| |**breakaway time adjustable**|0 ... 2 s| |**number ofparameter sets**|3| |**accuracy class**|5(based on IEC 61557-12)| |**certificate of suitability**|| |● CE marking|Yes| Subject to change without notice © Copyright Siemens 3RW55133HA05 Page 1/9 5/30/2026 |● UL approval|Yes| |---|---| |● CSA approval|Yes| |**product component**|| |● HMI-High Feature|Yes| |● is supported HMI-High Feature|Yes| |**product feature integrated bypass contact system**|Yes| |**number of controlledphases**|3| |**current unbalance limiting value[%]**|10 ... 60 %| |**ground-fault monitoring limiting value[%]**|10 ... 95 %| |**buffering time in the event ofpower failure**|| |● for main current circuit|100 ms| |● for control circuit|100 ms| |**idle time adjustable**|0 ... 255 s| |**insulation voltage rated value**|600 V| |**degree ofpollution**|3, acc. to IEC 60947-4-2| |**impulse voltage rated value**|6 kV| |**blocking voltage of the thyristor maximum**|1 600 V| |**service factor**|1.15| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● between main and auxiliarycircuit|600 V; does not applyfor thermistor connection| |**shock resistance**|15g/ 11 ms, from 6g/ 11 ms withpotential contact lifting| |**vibration resistance**|15 mm upto 6 Hz; 2gupto 500 Hz| |**recovery time after overload trip adjustable**|60 ... 1 800 s| |utilization categoryaccordingto IEC 60947-4-2|AC 53a| |**reference code according to IEC 81346-2**|Q| |**Substance Prohibitance(day/month/year)**|02/15/2018| |**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1<br>6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1<br>Dibutylbis(pentane-2,4-dionato-O,O')tin CAS-No. 22673-19-4<br>Diboron trioxide CAS-No. 1303-86-2<br>Lead titanium trioxide CAS-No. 12060-00-3| |**Net Weight**|3.2 kg| |**product function**|| |● ramp-up (soft starting)|Yes| |● soft stopping|Yes| |● breakaway pulse|Yes| |● adjustable current limitation|Yes| |● creepspeed in both directions of rotation|Yes| |●pumpstop|Yes| |● DC braking|Yes| |● motor heating|Yes| |● min/maxpointer|Yes| |● trace function|Yes| |● intrinsic deviceprotection|Yes| |● motor overload protection|Yes; Full motor protection (thermistor motor protection and electronic motor<br>overload protection) / When using the motor overload protection according to<br>ATEX, an upstream contactor is required in inside-delta circuit.| |● evaluation of thermistor motorprotection|Yes; Type A PTC or Klixon / Thermoclick| |● inside-delta circuit|Yes| |● auto-RESET|Yes| |● manual RESET|Yes| |● remote reset|Yes| |● communication function|Yes| |● operatingmeasured value display|Yes| |● event list|Yes| |● error logbook|Yes| |● via software parameterizable|Yes| Subject to change without notice © Copyright Siemens 3RW55133HA05 Page 2/9 5/30/2026 ||● via software configurable|Yes|| |---|---|---|---| ||● screw terminal|No|| ||● spring-loaded terminal|Yes|| ||**● PROFIenergy**|Yes; in connection with the PROFINET Standard and PROFINET High-Feature<br>communication modules|| ||**● firmware update**|Yes|| ||**● removable terminal for control circuit**|Yes|| ||● voltage ramp|Yes|| ||● torque control|Yes|| ||● combined braking|Yes|| ||● analogoutput|Yes; 4 ... 20 mA(default)/ 0 ... 10 V|| ||●programmable control inputs/outputs|Yes|| ||● condition monitoring|Yes|| ||● automaticparameterisation|Yes|| ||● application wizards|Yes|| ||● alternative stoppingmode|Yes|| ||● emergencyoperation mode|Yes|| ||● reversingoperation|Yes|| ||● soft startingat heavystartingconditions|Yes|| ||**Power Electronics**||| ||**operational current**||| ||● at 40 °C rated value|13 A|| ||● at 40 °C rated value minimum|2.5 A|| ||● at 50 °C rated value|11.5 A|| ||● at 60 °C rated value|10.5 A|| ||**operational current at inside-delta circuit**||| ||● at 40 °C rated value|22.5 A|| ||● at 50 °C rated value|19.9 A|| ||● at 60 °C rated value|18.2 A|| ||**operating voltage**||| ||● rated value|200 ... 600 V|| ||● at inside-delta circuit rated value|200 ... 600 V|| ||**relative negative tolerance of the operating voltage**|-15 %|| ||**relativepositive tolerance of the operating voltage**|10 %|| ||**relative negative tolerance of the operating voltage at**<br>**inside-delta circuit**|-15 %|| ||**relative positive tolerance of the operating voltage at**<br>**inside-delta circuit**|10 %|| ||**operating power for 3-phase motors**||| ||● at 230 V at 40 °C rated value|3 kW|| ||● at 230 V at inside-delta circuit at 40 °C rated value|5.5 kW|| ||● at 400 V at 40 °C rated value|5.5 kW|| ||● at 400 V at inside-delta circuit at 40 °C rated value|11 kW|| ||● at 500 V at 40 °C rated value|7.5 kW|| ||● at 500 V at inside-delta circuit at 40 °C rated value|15 kW|| ||**Operating frequency 1 rated value**|50 Hz|| ||**Operating frequency 2 rated value**|60 Hz|| ||**relative negative tolerance of the operating frequency**|-10 %|| ||**relativepositive tolerance of the operating frequency**|10 %|| ||**minimum load[%]**|10 %; Relative to set Ie|| ||**power loss[W] for rated value of the current at AC**||| ||● at 40 °C after startup|4 W|| ||● at 50 °C after startup|3 W|| ||● at 60 °C after startup|3 W|| ||**power loss[W] at AC at current limitation 350 %**||| ||● at 40 °C duringstartup|198 W|| ||● at 50 °C duringstartup|166 W|| ||● at 60 °C duringstartup|148 W|| ||**type of the motor protection**|Electronic, trippingin the event of thermal overload of the motor|| ||**Control circuit/ Control**||| Subject to change without notice © Copyright Siemens 3RW55133HA05 Page 3/9 5/30/2026 |**type of voltage of the control supply voltage**|AC/DC| |---|---| |**control supply voltage at AC**|| |● at 50 Hz rated value|24 V| |● at 60 Hz rated value|24 V| |**relative negative tolerance of the control supply voltage at**<br>**AC at 50 Hz**|-20 %| |**relative positive tolerance of the control supply voltage at**<br>**AC at 50 Hz**|20 %| |**relative negative tolerance of the control supply voltage at**<br>**AC at 60 Hz**|-20 %| |**relative positive tolerance of the control supply voltage at**<br>**AC at 60 Hz**|20 %| |**control supply voltage frequency**|50 ... 60 Hz| |**relative negative tolerance of the control supply voltage**<br>**frequency**|-10 %| |**relative positive tolerance of the control supply voltage**<br>**frequency**|10 %| |**control supply voltage at DC rated value**|24 V| |**relative negative tolerance of the control supply voltage at**<br>**DC**|-20 %| |**relative positive tolerance of the control supply voltage at**<br>**DC**|20 %| |**control supply current in standby mode rated value**|420 mA| |**holding current in bypass operation rated value**|820 mA| |**inrush current by closing the bypass contacts maximum**|0.91 A| |inrush current peak at application of control supply voltage<br>maximum|7.5 A| |duration of inrush current peak at application of control supply<br>voltage|20 ms| |**design of the overvoltage protection**|Varistor| |**design of short-circuit protection for control circuit**|4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit<br>breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of<br>scope of supply| |**Inputs/ Outputs**|| |**number of digital inputs**|4| |●parameterizable|4| ||| |**● number of digital outputs**|4| |● number of digital outputsparameterizable|3| |● number of digital outputs notparameterizable|1| |**digital output version**|3 normally-open contacts(NO)/ 1 changeover contact(CO)| |**number of analog outputs**|1| |**switching capacity current of the relay outputs**|| |● at AC-15 at 250 V rated value|3 A| |● at DC-13 at 24 V rated value|1 A| |**Installation/ mounting/ dimensions**|| |**mounting position**|Vertical(can be rotated +/- 90° and tilted forward or backward +/- 22.5°)| |**fastening method**|screw fixing| |**height**|275 mm| |**width**|170 mm| |**depth**|152 mm| |required spacingwith side-by-side mounting|| |● forwards|10 mm| |● backwards|0 mm| |● upwards|100 mm| |● downwards|75 mm| |● at the side|5 mm| |**weight without packaging**|2.3 kg| |**Connections/ Terminals**|| |**type of electrical connection**|| |● for main current circuit|screw-type terminals| |● for control circuit|spring-loaded terminals| Subject to change without notice © Copyright Siemens 3RW55133HA05 Page 4/9 5/30/2026 ||**wire length for thermistor connection**||| |---|---|---|---| ||● with conductor cross-section = 0.5 mm² maximum|50 m|| ||● with conductor cross-section = 1.5 mm² maximum|150 m|| ||● with conductor cross-section = 2.5 mm² maximum|250 m|| ||**type of connectable conductor cross-sections**||| ||● for main contacts||| ||— solid|2x(1.0 ... 2.5 mm²), 2x(2.5 ... 10 mm²)|| ||— finelystranded with core endprocessing|2x(1.0 ... 2.5 mm²), 2x(2.5 ... 6.0 mm²)|| ||● for AWG cables for main current circuit solid|2x(16 ... 12), 2x(14 ... 8)|| ||**type of connectable conductor cross-sections**||| ||● for control circuit solid|2x(0.25 ... 1.5 mm²)|| ||● for control circuit finelystranded with core endprocessing|2x(0.25 ... 1.5 mm²)|| ||● for AWG cables for control circuit solid|2x(24 ... 16)|| ||● for AWG cables for control circuit finely stranded with<br>core endprocessing|2x (24 ... 16)|| ||**wire length**||| ||● between soft starter and motor maximum|800 m|| ||● at the digital inputs at DC maximum|1 000 m|| ||**Ambient conditions**||| ||installation altitude at height above sea level maximum|5 000 m|| ||**ambient temperature**||| ||● duringoperation|-25 ... +60 °C; Please observe deratingat temperatures of 40 °C or above|| ||● duringstorage and transport|-25 ... +80 °C|| ||**environmental category**||| ||● during operation according to IEC 60721|3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2<br>(sand must notget into the devices), 3M6|| ||● during storage according to IEC 60721|1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get<br>inside the devices), 1M4|| ||● duringtransport accordingto IEC 60721|2K2, 2C1, 2S1, 2M2(max. fall height 0.3 m)|| ||**Electromagnetic compatibility**||| ||**EMC emitted interference**|acc. to IEC 60947-4-2: Class A|| ||**Communication/ Protocol**||| ||**communication module is supported**||| ||● PROFINET standard|Yes|| ||● PROFINET high-feature|No|| ||● EtherNet/IP|No|| ||● Modbus RTU|No|| ||● Modbus TCP|Yes|| ||● PROFIBUS|Yes|| ||**UL/CSA ratings**||| ||**manufacturer's article number**||| ||**● of circuit breaker usable for Standard Faults**||| ||— at 460/480 V accordingto UL|Siemens type: 3RV2742, max. 40 A or 3VA51, max. 40 A; Iq= 5 kA|| ||— 60/480 V accordingto UL|Siemens type: 3RV2742, max. 30 A or 3VA51, max. 35 A; Iqmax = 65 kA|| ||— at 460/480 V at inside-delta circuit accordingto UL|Siemens type: 3RV2742, max. 40 A or 3VA51, max. 40 A; Iq= 5 kA|| ||— 60/480 V at inside-delta circuit accordingto UL|Siemens type: 3RV2742, max. 30 A or 3VA51, max. 35 A; Iqmax = 65 kA|| ||— at 575/600 V accordingto UL|Siemens type: 3RV2742, max. 40 A or 3VA51, max. 40 A; Iq= 5 kA|| ||— 75/600 V at inside-delta circuit accordingto UL|Siemens type: 3RV2742, max. 30 A or 3VA51, max. 35 A; Iqmax = 65 kA|| ||— at 575/600 V at inside-delta circuit accordingto UL|Siemens type: 3RV2742, max. 40 A or 3VA51, max. 40 A; Iq= 5 kA|| ||**● of the fuse**||| ||— usable for Standard Faults up to 575/600 V<br>accordingto UL|Type: Class RK5 / K5, max. 50 A; Iq = 5 kA|| ||— usable for High Faults up to 575/600 V according to<br>UL|Type: Class J / L, max. 50 A; Iq = 100 kA|| ||— usable for Standard Faults at inside-delta circuit up<br>to 575/600 V accordingto UL|Type: Class RK5 / K5, max. 50 A; Iq = 5 kA|| ||— usable for High Faults at inside-delta circuit up to<br>575/600 V accordingto UL|Type: Class J / L, max. 50 A; Iq = 100 kA|| ||**operating power[hp] for 3-phase motors**||| ||● at 200/208 V at 50 °C rated value|2 hp|| ||● at 220/230 V at 50 °C rated value|3 hp|| Subject to change without notice © Copyright Siemens 3RW55133HA05 Page 5/9 5/30/2026 |● at 460/480 V at 50 °C rated value|7.5 hp| |---|---| |● at 575/600 V at 50 °C rated value|10 hp| |● at 200/208 V at inside-delta circuit at 50 °C rated value|5 hp| |● at 220/230 V at inside-delta circuit at 50 °C rated value|5 hp| |● at 460/480 V at inside-delta circuit at 50 °C rated value|10 hp| |● at 575/600 V at inside-delta circuit at 50 °C rated value<br>~~[py~~|15 hp<br>~~[py~~| |**contact rating of auxiliary contacts according to UL**<br>~~[py~~|R300-B300<br>~~[py~~| |Electrical Safety<br>~~[py~~|| |**protection class IP on the front according to IEC 60529**<br>~~[py~~|IP20<br>~~[py~~| |**touch protection on the front according to IEC 60529**|finger-safe, for vertical contact from the front| |**ATEX**<br>~~|~~|| |**Safety Integrity Level (SIL) according to IEC 61508 relating**<br>**to ATEX**<br>~~|~~|SIL 1<br>~~|~~| |**PFHD with high demand rate according to IEC 61508**<br>**relating to ATEX**|5E-7 1/h| |**PFDavg with low demand rate according to IEC 61508**<br>**relating to ATEX**|0.008| |**hardware fault tolerance according to IEC 61508 relating to**<br>**ATEX**|0| |**T1 value for proof test interval or service life according to**<br>**IEC 61508 relating to ATEX**|3 a| |**certificate of suitability**|| |● ATEX|Yes| |● IECEx|Yes| |● accordingto ATEX directive 2014/34/EU|BVS 18 ATEX F 003 X| |**type of protection according to ATEX directive 2014/34/EU**|II (2)G [Ex eb Gb] [Ex db Gb] [Ex pxb Gb], II (2)D [Ex tb Db] [Ex pxb Db], I (M2)<br>[Ex db Mb]| |**Approvals Certificates**<br>~~ee~~|| |Environmental Product Declaration<br>● global warming potential [CO2 eq] / during manufacturing<br>50.8 kg<br>● global warming potential [CO2 eq] / during sales<br>0.827 kg<br>● global warming potential [CO2 eq] / during operation<br>240 kg<br>● global warming potential [CO2 eq] / after end of life<br>-7.11 kg<br>● global warming potential [CO2 eq] / total<br>285 kg<br>**Environment**<br>**General Product Approval**<br>~~ee~~|| Environmental Confirmations **General Product Approval EMV** **For use in hazardous locations** **Test Certificates** **Test Certificates Maritime application** - Type Test Certific ates/Test Report ~~—~~ @ ## **other** Confirmation Confirmation Subject to change without notice © Copyright Siemens 3RW55133HA05 Page 6/9 5/30/2026 **Further information Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RW5513-3HA05 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RW5513-3HA05 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RW5513-3HA05&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RW5513-3HA05 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **Characteristic: Tripping characteristics, I²t, Let-through current** https://support.industry.siemens.com/cs/ww/en/ps/3RW5513-3HA05/char **Characteristic: Installation altitude** https://www.automation.siemens.com/bilddb/index.aspx?gridview=view2&objkey=G_NSB0_XX_01704&showdetail=true&view=Search **Simulation Tool for Soft Starters (STS)** https://support.industry.siemens.com/cs/ww/en/view/101494917 Subject to change without notice © Copyright Siemens 3RW55133HA05 Page 7/9 5/30/2026 **==> picture [405 x 181] intentionally omitted <==** **----- Start of picture text -----**<br> -Q<br>aa — |<br>1/L1 3/L2 5/L3 A1 13 NO 23 NO 95 43 NO L+ M DI 1 DI 2 DI 3 DI 4<br>2/T1 4/T2 6/T3 A2 14 24 98 NO 96 NC 44 AQ I+ AQ U+ AQ- T1 T2<br>**----- End of picture text -----**<br> **last modified:** 9/5/2025 Subject to change without notice © Copyright Siemens 3RW55133HA05 Page 8/9 5/30/2026 Subject to change without notice © Copyright Siemens 3RW55133HA05 Page 9/9 5/30/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →