Image not available
Illustrative purposes only
3RW5074-2AB04
Soft Starter, 3RW Series, Three Phase, 315 A, 200 V to 480 V, 160 kW at 400 V, Spring Terminal
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Motor Starters
- SVHC: To Be Advised
- No. of Poles: 3 Pole
- Power Rating: 200kW
- No. of Phases: Three Phase
- Product Range: SIRIUS 3RW50
- Current Rating: 315A
- IP / NEMA Rating: IP00, IP20
- Motor Starter Type: Soft Starter
- Supply Voltage Max: 480VAC
- Supply Voltage Min: 200VAC
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 2340.3 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RW5074-2AB04** **Data sheet** SIRIUS soft starter 200-480 V 315 A, 24 V AC/DC Spring-loaded terminals Analog output |SIRIUS soft starter 200-480 V 315 A, 24 V AC/DC Spring-loaded terminals Analog<br>output<br>**product brand name**<br>SIRIUS<br>**product category**<br>Hybrid switchingdevices<br>**product designation**<br>Soft starter<br>**product type designation**<br>3RW50<br>**manufacturer's article number**<br>● of standard HMI module usable<br>3RW5980-0HS01<br>● of high feature HMI module usable<br>3RW5980-0HF00<br>● of communication module PROFINET standard usable<br>3RW5980-0CS00<br>● of communication module PROFIBUS usable<br>3RW5980-0CP00<br>● of communication module Modbus TCP usable<br>3RW5980-0CT00<br>● of communication module Modbus RTU usable<br>3RW5980-0CR00<br>● of communication module Ethernet/IP<br>3RW5980-0CE00<br>● of circuit breaker usable at 400 V<br>3VA2440-7MN32-0AA0; Type of assignment 1, Iq=65 kA<br>● of circuit breaker usable at 500 V<br>3VA2440-7MN32-0AA0; Type of assignment 1, Iq=65 kA<br>● of thegG fuse usable upto 690 V<br>2x3NA3365-6; Type of coordination 1, Iq= 65 kA<br>● of full range R fuse link for semiconductor protection<br>usable upto 690 V<br>3NE1 333-2; Type of coordination 2, Iq=65 kA<br>● of back-up R fuse link for semiconductor protection<br>usable upto 690 V<br>3NE3 335; Type of coordination 2, Iq=65 kA<br>● of line contactor usable upto 480 V<br>3RT1075<br>● of line contactor usable up to 690 V<br>3RT1075<br>**General technical data**<br>**starting voltage [%]**<br>30 ... 100 %<br>**stopping voltage [%]**<br>50 %; non-adjustable<br>**start-up ramp time of soft starter**<br>0 ... 20 s<br>**ramp-down time of soft starter**<br>0 ... 20 s<br>**current limiting value[%] adjustable**<br>130 ... 700 %<br>**certificate of suitability**<br>● CE marking<br>Yes<br>● UL approval<br>Yes<br>● CSA approval<br>Yes<br>**product component**<br>● HMI-High Feature<br>No<br>● is supported HMI-Standard<br>Yes<br>● is supported HMI-High Feature<br>Yes<br>**product feature integrated bypass contact system**<br>Yes<br>**number of controlledphases**<br>2<br>**buffering time in the event ofpower failure**<br>● for main current circuit<br>100 ms<br>● for control circuit<br>100 ms<br>**insulation voltage rated value**<br>600 V<br>**degree ofpollution**<br>3, acc. to IEC 60947-4-2<br>**impulse voltage rated value**<br>6 kV<br>**blocking voltage of the thyristor maximum**<br>1 600 V<br>**service factor**<br>1<br>**surge voltage resistance rated value**<br>6 kV<br>**maximumpermissible voltage forprotective separation**<br>● between main and auxiliary circuit<br>600 V<br>Siemens<br>EcoTech|SIRIUS soft starter 200-480 V 315 A, 24 V AC/DC Spring-loaded terminals Analog<br>output|| |---|---|---| ||SIRIUS|| ||Hybrid switchingdevices|| ||Soft starter|| ||3RW50|| |||| ||3RW5980-0HS01|| ||3RW5980-0HF00|| ||3RW5980-0CS00|| ||3RW5980-0CP00|| ||3RW5980-0CT00|| ||3RW5980-0CR00|| ||3RW5980-0CE00|| ||3VA2440-7MN32-0AA0; Type of assignment 1, Iq=65 kA|| ||3VA2440-7MN32-0AA0; Type of assignment 1, Iq=65 kA|| ||2x3NA3365-6; Type of coordination 1, Iq= 65 kA|| ||3NE1 333-2; Type of coordination 2, Iq=65 kA|| ||3NE3 335; Type of coordination 2, Iq=65 kA|| ||3RT1075|| ||3RT1075|| ||30 ... 100 %|| ||50 %; non-adjustable|| ||0 ... 20 s|| ||0 ... 20 s|| ||130 ... 700 %|| |||| ||Yes|| ||Yes|| ||Yes|| |||| ||No|| ||Yes|| ||Yes|| ||Yes|| ||2|| |||| ||100 ms|| ||100 ms|| ||600 V|| ||3, acc. to IEC 60947-4-2|| ||6 kV|| ||1 600 V|| ||1|| ||6 kV|| |||| ||600 V|| Subject to change without notice © Copyright Siemens 3RW50742AB04 Page 1/7 5/31/2026 ||**shock resistance**|15g/ 11 ms, from 12g/ 11 ms withpotential contact lifting|| |---|---|---|---| ||**vibration resistance**|15 mm to 6 Hz; 2gto 500 Hz|| ||utilization categoryaccordingto IEC 60947-4-2|AC-53a|| ||**reference code according to IEC 81346-2**|Q|| ||**Substance Prohibitance(day/month/year)**|09/23/2019|| ||**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol CAS-No. 79-94-7<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1<br>6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1|| ||**Net Weight**|8.058 kg|| ||**product function**||| ||● ramp-up (soft starting)|Yes|| ||● soft stopping|Yes|| ||● Soft Torque|Yes|| ||● adjustable current limitation|Yes|| ||●pumpstop|Yes|| ||● intrinsic deviceprotection|Yes|| ||● motor overloadprotection|Yes; Electronic motor overloadprotection|| ||● evaluation of thermistor motorprotection|No|| ||● auto-RESET|Yes|| ||● manual RESET|Yes|| ||● remote reset|Yes; Byturningoff the control supplyvoltage|| ||● communication function|Yes|| ||● operatingmeasured value display|Yes; Onlyin conjunction with special accessories|| ||● error logbook|Yes; Onlyin conjunction with special accessories|| ||● via softwareparameterizable|No|| ||● via software configurable|Yes|| ||**● PROFIenergy**|Yes; in connection with the PROFINET Standard communication module|| ||● voltage ramp|Yes|| ||● torque control|No|| ||● analogoutput|Yes; 4 ... 20 mA(default)/ 0 ... 10 V(parameterizable with High Feature HMI)|| ||**Power Electronics**||| ||**operational current**||| ||● at 40 °C rated value|315 A|| ||● at 50 °C rated value|279 A|| ||● at 60 °C rated value|255 A|| ||**operating voltage**||| ||● rated value|200 ... 480 V|| ||**relative negative tolerance of the operating voltage**|-15 %|| ||**relativepositive tolerance of the operating voltage**|10 %|| ||**operating power for 3-phase motors**||| ||● at 230 V at 40 °C rated value|90 kW|| ||● at 400 V at 40 °C rated value|160 kW|| ||**Operating frequency 1 rated value**|50 Hz|| ||**Operating frequency 2 rated value**|60 Hz|| ||**relative negative tolerance of the operating frequency**|-10 %|| ||**relativepositive tolerance of the operating frequency**|10 %|| ||**adjustable motor current**||| ||● at rotarycodingswitch on switchposition 1|135 A|| ||● at rotarycodingswitch on switchposition 2|147 A|| ||● at rotarycodingswitch on switchposition 3|159 A|| ||● at rotarycodingswitch on switchposition 4|171 A|| ||● at rotarycodingswitch on switchposition 5|183 A|| ||● at rotarycodingswitch on switchposition 6|195 A|| ||● at rotarycodingswitch on switchposition 7|207 A|| ||● at rotarycodingswitch on switchposition 8|219 A|| ||● at rotarycodingswitch on switchposition 9|231 A|| ||● at rotary coding switch on switch position 10|243 A|| Subject to change without notice © Copyright Siemens 3RW50742AB04 Page 2/7 5/31/2026 ||● at rotarycodingswitch on switchposition 11|255 A|| |---|---|---|---| ||● at rotarycodingswitch on switchposition 12|267 A|| ||● at rotarycodingswitch on switchposition 13|279 A|| ||● at rotarycodingswitch on switchposition 14|291 A|| ||● at rotarycodingswitch on switchposition 15|303 A|| ||● at rotarycodingswitch on switchposition 16|315 A|| ||● minimum|135 A|| ||**minimum load[%]**|15 %; Relative to smallest settable Ie|| ||**power loss[W] for rated value of the current at AC**||| ||● at 40 °C after startup|36 W|| ||● at 50 °C after startup|29 W|| ||● at 60 °C after startup|24 W|| ||**power loss[W] at AC at current limitation 350 %**||| ||● at 40 °C duringstartup|3 368 W|| ||● at 50 °C duringstartup|2 805 W|| ||● at 60 °C duringstartup|2 455 W|| ||**type of the motor protection**|Electronic, trippingin the event of thermal overload of the motor|| ||**Control circuit/ Control**||| ||**type of voltage of the control supply voltage**|AC/DC|| ||**control supply voltage at AC**||| ||● at 50 Hz rated value|24 V|| ||● at 60 Hz rated value|24 V|| ||**relative negative tolerance of the control supply voltage at**<br>**AC at 50 Hz**|-20 %|| ||**relative positive tolerance of the control supply voltage at**<br>**AC at 50 Hz**|20 %|| ||**relative negative tolerance of the control supply voltage at**<br>**AC at 60 Hz**|-20 %|| ||**relative positive tolerance of the control supply voltage at**<br>**AC at 60 Hz**|20 %|| ||**control supply voltage frequency**|50 ... 60 Hz|| ||**relative negative tolerance of the control supply voltage**<br>**frequency**|-10 %|| ||**relative positive tolerance of the control supply voltage**<br>**frequency**|10 %|| ||**control supply voltage at DC rated value**|24 V|| ||**relative negative tolerance of the control supply voltage at**<br>**DC**|-20 %|| ||**relative positive tolerance of the control supply voltage at**<br>**DC**|20 %|| ||**control supply current in standby mode rated value**|160 mA|| ||**holding current in bypass operation rated value**|490 mA|| ||**inrush current by closing the bypass contacts maximum**|7.6 A|| ||inrush current peak at application of control supply voltage<br>maximum|3.3 A|| ||duration of inrush current peak at application of control supply<br>voltage|12.1 ms|| ||**design of the overvoltage protection**|Varistor|| ||**design of short-circuit protection for control circuit**|4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit<br>breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of<br>scope of supply|| ||**Inputs/ Outputs**||| ||**number of digital inputs**|1|| ||**number of digital outputs**|3|| ||● notparameterizable|2|| ||**digital output version**|2 normally-open contacts(NO)/ 1 changeover contact(CO)|| ||**number of analog outputs**|1|| ||**switching capacity current of the relay outputs**||| ||● at AC-15 at 250 V rated value|3 A|| ||● at DC-13 at 24 V rated value|1 A|| ||**Installation/ mounting/ dimensions**||| ||**mounting position**|with vertical mounting surface +/-90° rotatable, with vertical mounting surface<br>+/- 22.5° tiltable to the front and back|| Subject to change without notice © Copyright Siemens 3RW50742AB04 Page 3/7 5/31/2026 ||**fastening method**|screw fixing|| |---|---|---|---| ||**height**|230 mm|| ||**width**|160 mm|| ||**depth**|282 mm|| ||required spacingwith side-by-side mounting||| ||● forwards|10 mm|| ||● backwards|0 mm|| ||● upwards|100 mm|| ||● downwards|75 mm|| ||● at the side|5 mm|| ||**weight without packaging**|7.3 kg|| ||**Connections/ Terminals**||| ||**type of electrical connection**||| ||● for main current circuit|busbar connection|| ||● for control circuit|spring-loaded terminals|| ||**width of connection bar maximum**|35 mm; with connection cover 3RT1966-4EA1 maximum length 45 mm|| ||**type of connectable conductor cross-sections for main**<br>**contacts for box terminal**||| ||● usingthe front clamping point solid|95 ... 300 mm²|| ||● using the front clamping point finely stranded with core<br>endprocessing|70 ... 240 mm²|| ||● using the front clamping point finely stranded without core<br>endprocessing|70 ... 240 mm²|| ||● usingthe front clamping point stranded|95 ... 300 mm²|| ||● usingthe back clamping point solid|120 ... 240 mm²|| ||● r box terminal usingthe back clamping point|250 ... 500 kcmil|| ||● usingboth clamping points solid|min. 2x 70 mm², max. 2x 240 mm²|| ||● using both clamping points finely stranded with core end<br>processing|min. 2x 50 mm², max. 2x 185 mm²|| ||● using both clamping points finely stranded without core<br>endprocessing|min. 2x 50 mm², max. 2x 185 mm²|| ||● usingboth clamping points stranded|min. 2x 70 mm², max. 2x 240 mm²|| ||● using the back clamping point finely stranded with core<br>endprocessing|120 ... 185 mm²|| ||● using the back clamping point finely stranded without core<br>endprocessing|120 ... 185 mm²|| ||● usingthe back clamping point stranded|120 ... 240 mm²|| ||**type of connectable conductor cross-sections**||| ||● for AWG cables for main current circuit solid|2/0 ... 500 kcmil|| ||● for DIN cable lugfor main contacts stranded|50 ... 240 mm²|| ||● for DIN cable lugfor main contacts finelystranded|70 ... 240 mm²|| ||**type of connectable conductor cross-sections**||| ||● for control circuit solid|2x(0.25 ... 1.5 mm²)|| ||● for control circuit finelystranded with core endprocessing|2x(0.25 ... 1.5 mm²)|| ||● for AWG cables for control circuit solid|2x(24 ... 16)|| ||● for AWG cables for control circuit finely stranded with<br>core endprocessing|2x (24 ... 16)|| ||**wire length**||| ||● between soft starter and motor maximum|800 m|| ||● at the digital inputs at AC maximum|1 000 m|| ||**tightening torque**||| ||● for main contacts with screw-type terminals|14 ... 24 N·m|| ||● for auxiliary and control contacts with screw-type<br>terminals|0.8 ... 1.2 N·m|| ||**tightening torque[lbf·in]**||| ||● for main contacts with screw-type terminals|124 ... 210 lbf·in|| ||● for auxiliary and control contacts with screw-type<br>terminals|7 ... 10.3 lbf·in|| ||**Ambient conditions**||| ||installation altitude at height above sea level maximum|5 000 m|| ||**ambient temperature**||| ||● during operation|-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above|| Subject to change without notice © Copyright Siemens 3RW50742AB04 Page 4/7 5/31/2026 **==> picture [511 x 662] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |● during storage and transport|-40 ... +80 °C| |environmental category| |● during operation according to IEC 60721|3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2| |(sand must not get into the devices), 3M6| |● during storage according to IEC 60721|1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get| |inside the devices), 1M4| |● during transport according to IEC 60721|2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)| |ee|Electromagnetic compatibility| |EMC emitted interference|acc. to IEC 60947-4-2: Class A| |ee|Communication/ Protocol| |communication module is supported| |● PROFINET standard|Yes| |● EtherNet/IP|Yes| |● Modbus RTU|Yes| |● Modbus TCP|Yes| |● PROFIBUS|Yes| |ee|UL/CSA ratings| |manufacturer's article number| |● of circuit breaker| |— usable for High Faults at 460/480 V according to UL|Siemens type: 3VA54, max. 600 A; Iq max = 65 kA| |● of the fuse| |— usable for Standard Faults up to 575/600 V|Type: Class L, max. 1000 A; Iq = 18 kA| |according to UL| |— usable for High Faults up to 575/600 V according to|Type: Class L, max. 1000 A; Iq = 100 kA| |UL| |operating|power [hp] for 3-phase motors| |● at 200/208 V at 50 °C rated value|75 hp| |● at 220/230 V at 50 °C rated value|100 hp| |● at 460/480 V at 50 °C rated value|200 hp| |ee|Electrical Safety| |protection class IP on the front according to IEC 60529|IP00; IP20 with cover| |touch protection on the front according to IEC 60529|finger-safe, for vertical contact from the front with cover| |ATEX| |ee| |Safety Integrity Level (SIL) according to IEC 61508 relating|SIL 1| |to ATEX| |PFHD with high demand rate according to IEC 61508|9E-6 1/h| |relating to ATEX| |PFDavg with low demand rate according to IEC 61508|0.09| |relating to ATEX| |hardware fault tolerance according to IEC 61508 relating to|0| |ATEX| |T1 value for proof test interval or service life according to|3 a| |IEC 61508 relating to ATEX| |certificate of suitability| |● ATEX|Yes| |● IECEx|Yes| |● UKEX|Yes| |Approvals Certificates| |—|Environmental Product Declaration|——| |● global warming potential [CO2 eq] / during manufacturing|87.4 kg| |● global warming potential [CO2 eq] / during sales|2.05 kg| |● global warming potential [CO2 eq] / during operation|407 kg| |● global warming potential [CO2 eq] / after end of life|-32.4 kg| |● global warming potential [CO2 eq] / total|464 kg| |Environment|General Product Approval| **----- End of picture text -----**<br> Environmental Confirmations Subject to change without notice © Copyright Siemens 3RW50742AB04 Page 5/7 5/31/2026 **General Product Approval EMV For use in hazardous locations** cé ca |e ~~©~~ Miscellaneous **Test Certificates Maritime application other** Type Test CertificConfirmation ates/Test Report ~~—e~~ @ 8 ~~=e~~ **other** Confirmation QC PASS ~~—~~ ae **Further information** ~~OO —SCSC;i‘sCCSCiés~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RW5074-2AB04 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RW5074-2AB04 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RW5074-2AB04&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RW5074-2AB04 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **Characteristic: Tripping characteristics, I²t, Let-through current** https://support.industry.siemens.com/cs/ww/en/ps/3RW5074-2AB04/char **Characteristic: Installation altitude** https://www.automation.siemens.com/bilddb/index.aspx?gridview=view2&objkey=G_NSB0_XX_01704&showdetail=true&view=Search **Simulation Tool for Soft Starters (STS)** https://support.industry.siemens.com/cs/ww/en/view/101494917 **last modified:** 4/4/2026 Subject to change without notice © Copyright Siemens 3RW50742AB04 Page 6/7 5/31/2026 Subject to change without notice © Copyright Siemens 3RW50742AB04 Page 7/7 5/31/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →