Image not available
Illustrative purposes only
3RW5055-6AB14
Soft Starter, 3RW Series, Three Phase, 143 A, 200 V to 480 V, 75 kW at 400 V, Screw
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Motor Starters
- SVHC: To Be Advised
- No. of Poles: 3 Pole
- Power Rating: 90kW
- No. of Phases: Three Phase
- Product Range: SIRIUS 3RW50
- Current Rating: 143A
- IP / NEMA Rating: IP00, IP20
- Motor Starter Type: Soft Starter
- Supply Voltage Max: 480VAC
- Supply Voltage Min: 200VAC
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1557.3 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RW5055-6AB14** **Data sheet** SIRIUS soft starter 200-480 V 143 A, 110-250 V AC Screw terminals Analog output |**product brand name**|SIRIUS| |---|---| |**product category**|Hybrid switchingdevices| |**product designation**|Soft starter| |**product type designation**|3RW50| |**manufacturer's article number**|| |● of standard HMI module usable|3RW5980-0HS01| |● of high feature HMI module usable|3RW5980-0HF00| |● of communication module PROFINET standard usable|3RW5980-0CS00| |● of communication module PROFIBUS usable|3RW5980-0CP00| |● of communication module Modbus TCP usable|3RW5980-0CT00| |● of communication module Modbus RTU usable|3RW5980-0CR00| |● of communication module Ethernet/IP|3RW5980-0CE00| |● of circuit breaker usable at 400 V|3VA2220-7MN32-0AA0; Type of assignment 1, Iq=20 kA| |● of circuit breaker usable at 500 V|3VA2220-7MN32-0AA0; Type of assignment 1, Iq=20 kA| |● of thegG fuse usable upto 690 V|3NA3244-6; Type of coordination 1, Iq=65 kA| |● of full range R fuse link for semiconductor protection|3NE1 227-0; Type of coordination 2, Iq=65 kA| |usable upto 690 V|| |● of back-up R fuse link for semiconductor protection|3NE3 334-0B; Type of coordination 2, Iq=65 kA| |usable upto 690 V|| |● of line contactor usable upto 480 V|3RT1055| |● of line contactor usable up to 690 V|3RT1055| |**General technical data**|| |**starting voltage [%]**|30 ... 100 %| |**stopping voltage [%]**|50 %; non-adjustable| |**start-up ramp time of soft starter**|0 ... 20 s| |**ramp-down time of soft starter**|0 ... 20 s| |**current limiting value[%] adjustable**|130 ... 700 %| |**certificate of suitability**|| |● CE marking|Yes| |● UL approval|Yes| |● CSA approval|Yes| |**product component**|| |● HMI-High Feature|No| |● is supported HMI-Standard|Yes| |● is supported HMI-High Feature|Yes| |**product feature integrated bypass contact system**|Yes| |**number of controlled phases**|2| Subject to change without notice © Copyright Siemens 3RW50556AB14 Page 1/9 5/29/2026 ||**buffering time in the event ofpower failure**||| |---|---|---|---| ||● for main current circuit|100 ms|| ||● for control circuit|100 ms|| ||**insulation voltage rated value**|600 V|| ||**degree ofpollution**|3, acc. to IEC 60947-4-2|| ||**impulse voltage rated value**|6 kV|| ||**blocking voltage of the thyristor maximum**|1 400 V|| ||**service factor**|1|| ||**surge voltage resistance rated value**|6 kV|| ||**maximumpermissible voltage forprotective separation**||| ||● between main and auxiliarycircuit|600 V|| ||**shock resistance**|15g/ 11 ms, from 12g/ 11 ms withpotential contact lifting|| ||**vibration resistance**|15 mm to 6 Hz; 2gto 500 Hz|| ||utilization categoryaccordingto IEC 60947-4-2|AC-53a|| ||**reference code according to IEC 81346-2**|Q|| ||**Substance Prohibitance(day/month/year)**|09/23/2019|| ||**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol CAS-No. 79-94-7<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1<br>6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1|| ||**Net Weight**|3.979 kg|| ||**product function**||| ||● ramp-up (soft starting)|Yes|| ||● soft stopping|Yes|| ||● Soft Torque|Yes|| ||● adjustable current limitation|Yes|| ||●pumpstop|Yes|| ||● intrinsic deviceprotection|Yes|| ||● motor overloadprotection|Yes; Electronic motor overloadprotection|| ||● evaluation of thermistor motorprotection|No|| ||● auto-RESET|Yes|| ||● manual RESET|Yes|| ||● remote reset|Yes; Byturningoff the control supplyvoltage|| ||● communication function|Yes|| ||● operatingmeasured value display|Yes; Onlyin conjunction with special accessories|| ||● error logbook|Yes; Onlyin conjunction with special accessories|| ||● via softwareparameterizable|No|| ||● via software configurable|Yes|| ||**● PROFIenergy**|Yes; in connection with the PROFINET Standard communication module|| ||● voltage ramp|Yes|| ||● torque control|No|| ||● analogoutput|Yes; 4 ... 20 mA(default)/ 0 ... 10 V(parameterizable with High Feature HMI)|| ||**Power Electronics**||| ||**operational current**||| ||● at 40 °C rated value|143 A|| ||● at 50 °C rated value|128 A|| ||● at 60 °C rated value|118 A|| ||**operating voltage**||| ||● rated value|200 ... 480 V|| ||**relative negative tolerance of the operating voltage**|-15 %|| ||**relativepositive tolerance of the operating voltage**|10 %|| ||**operating power for 3-phase motors**||| ||● at 230 V at 40 °C rated value|37 kW|| ||● at 400 V at 40 °C rated value|75 kW|| ||**Operating frequency 1 rated value**|50 Hz|| ||**Operating frequency 2 rated value**|60 Hz|| ||**relative negative tolerance of the operating frequency**|-10 %|| ||**relative positive tolerance of the operating frequency**|10 %|| Subject to change without notice © Copyright Siemens 3RW50556AB14 Page 2/9 5/29/2026 ||**adjustable motor current**||| |---|---|---|---| ||● at rotarycodingswitch on switchposition 1|68 A|| ||● at rotarycodingswitch on switchposition 2|73 A|| ||● at rotarycodingswitch on switchposition 3|78 A|| ||● at rotarycodingswitch on switchposition 4|83 A|| ||● at rotarycodingswitch on switchposition 5|88 A|| ||● at rotarycodingswitch on switchposition 6|93 A|| ||● at rotarycodingswitch on switchposition 7|98 A|| ||● at rotarycodingswitch on switchposition 8|103 A|| ||● at rotarycodingswitch on switchposition 9|108 A|| ||● at rotarycodingswitch on switchposition 10|113 A|| ||● at rotarycodingswitch on switchposition 11|118 A|| ||● at rotarycodingswitch on switchposition 12|123 A|| ||● at rotarycodingswitch on switchposition 13|128 A|| ||● at rotarycodingswitch on switchposition 14|133 A|| ||● at rotarycodingswitch on switchposition 15|138 A|| ||● at rotarycodingswitch on switchposition 16|143 A|| ||● minimum|68 A|| ||**minimum load[%]**|15 %; Relative to smallest settable Ie|| ||**power loss[W] for rated value of the current at AC**||| ||● at 40 °C after startup|23 W|| ||● at 50 °C after startup|19 W|| ||● at 60 °C after startup|16 W|| ||**power loss[W] at AC at current limitation 350 %**||| ||● at 40 °C duringstartup|1 336 W|| ||● at 50 °C duringstartup|1 134 W|| ||● at 60 °C duringstartup|1 007 W|| ||**type of the motor protection**|Electronic, trippingin the event of thermal overload of the motor|| ||**Control circuit/ Control**||| ||**type of voltage of the control supply voltage**|AC|| ||**control supply voltage at AC**||| ||● at 50 Hz|110 ... 250 V|| ||● at 60 Hz|110 ... 250 V|| ||**relative negative tolerance of the control supply voltage at**<br>**AC at 50 Hz**|-15 %|| ||**relative positive tolerance of the control supply voltage at**<br>**AC at 50 Hz**|10 %|| ||**relative negative tolerance of the control supply voltage at**<br>**AC at 60 Hz**|-15 %|| ||**relative positive tolerance of the control supply voltage at**<br>**AC at 60 Hz**|10 %|| ||**control supply voltage frequency**|50 ... 60 Hz|| ||**relative negative tolerance of the control supply voltage**<br>**frequency**|-10 %|| ||**relative positive tolerance of the control supply voltage**<br>**frequency**|10 %|| ||**control supply current in standby mode rated value**|30 mA|| ||**holding current in bypass operation rated value**|80 mA|| ||**inrush current by closing the bypass contacts maximum**|2.5 A|| ||inrush current peak at application of control supply voltage<br>maximum|12.2 A|| ||duration of inrush current peak at application of control supply<br>voltage|2.2 ms|| ||**design of the overvoltage protection**|Varistor|| ||**design of short-circuit protection for control circuit**|4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit<br>breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of<br>scope of supply|| ||**Inputs/ Outputs**||| ||**number of digital inputs**|1|| ||**number of digital outputs**|3|| ||● notparameterizable|2|| ||**digital output version**|2 normally-open contacts (NO) / 1 changeover contact (CO)|| Subject to change without notice © Copyright Siemens 3RW50556AB14 Page 3/9 5/29/2026 |**number of analog outputs**|1| |---|---| |**switching capacity current of the relay outputs**|| |● at AC-15 at 250 V rated value|3 A| |● at DC-13 at 24 V rated value|1 A| |**Installation/ mounting/ dimensions**|| |**mounting position**|with vertical mounting surface +/-90° rotatable, with vertical mounting surface<br>+/- 22.5° tiltable to the front and back| |**fastening method**|screw fixing| |**height**|198 mm| |**width**|120 mm| |**depth**|249 mm| |required spacingwith side-by-side mounting|| |● forwards|10 mm| |● backwards|0 mm| |● upwards|100 mm| |● downwards|75 mm| |● at the side|5 mm| |**weight without packaging**|3.2 kg| |**Connections/ Terminals**|| |**type of electrical connection**|| |● for main current circuit|busbar connection| |● for control circuit|screw-type terminals| |**width of connection bar maximum**|25 mm| |**type of connectable conductor cross-sections for main**<br>**contacts for box terminal**|| |● usingthe front clamping point solid|16 ... 120 mm²| |● using the front clamping point finely stranded with core<br>endprocessing|16 ... 120 mm²| |● using the front clamping point finely stranded without core<br>endprocessing|10 ... 120 mm²| |● usingthe front clamping point stranded|16 ... 70 mm²| |● usingthe back clamping point solid|16 ... 120 mm²| |● r box terminal usingthe back clamping point|6 ... 250 kcmil| |● usingboth clamping points solid|max. 1x 95 mm², 1x 120 mm²| |● using both clamping points finely stranded with core end<br>processing|max. 1x 95 mm², 1x 120 mm²| |● using both clamping points finely stranded without core<br>endprocessing|max. 1x 95 mm², 1x 120 mm²| |● usingboth clamping points stranded|max. 2x 120 mm²| |● using the back clamping point finely stranded with core<br>endprocessing|16 ... 120 mm²| |● using the back clamping point finely stranded without core<br>endprocessing|10 ... 120 mm²| |● usingthe back clamping point stranded|16 ... 120 mm²| |**type of connectable conductor cross-sections**|| |● for AWG cables for main current circuit solid|4 ... 250 kcmil| |● for DIN cable lugfor main contacts stranded|16 ... 95 mm²| |● for DIN cable lugfor main contacts finelystranded|25 ... 120 mm²| |**type of connectable conductor cross-sections**|| |● for control circuit solid|1x(0.5 ... 4.0 mm²), 2x(0.5 ... 2.5 mm²)| |● for control circuit finelystranded with core endprocessing|1x(0.5 ... 2.5 mm²), 2x(0.5 ... 1.5 mm²)| |● for AWG cables for control circuit solid|1x(20 ... 12), 2x(20 ... 14)| |**wire length**|| |● between soft starter and motor maximum|800 m| |● at the digital inputs at AC maximum|1 000 m| |**tightening torque**|| |● for main contacts with screw-type terminals|10 ... 14 N·m| |● for auxiliary and control contacts with screw-type<br>terminals|0.8 ... 1.2 N·m| |**tightening torque[lbf·in]**|| |● for main contacts with screw-type terminals|89 ... 124 lbf·in| Subject to change without notice © Copyright Siemens 3RW50556AB14 Page 4/9 5/29/2026 |● for auxiliary and control contacts with screw-type<br>terminals|7 ... 10.3 lbf·in|7 ... 10.3 lbf·in| |---|---|---| |**Ambient conditions**||| |installation altitude at height above sea level maximum|5 000 m|| |**ambient temperature**||| |● duringoperation|-25 ... +60 °C; Please observe deratingat temperatures of 40 °C or above|| |● duringstorage and transport|-40 ... +80 °C|| |**environmental category**||| |● during operation according to IEC 60721|3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2<br>(sand must notget into the devices), 3M6|| |● during storage according to IEC 60721|1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get<br>inside the devices), 1M4|| |● duringtransport accordingto IEC 60721|2K2, 2C1, 2S1, 2M2(max. fall height 0.3 m)|| |**Electromagnetic compatibility**||| |**EMC emitted interference**|acc. to IEC 60947-4-2: Class A|| |**Communication/ Protocol**||| |**communication module is supported**||| |● PROFINET standard|Yes|| |● EtherNet/IP|Yes|| |● Modbus RTU|Yes|| |● Modbus TCP|Yes|| |● PROFIBUS|Yes|| |**UL/CSA ratings**||| |**manufacturer's article number**||| |**● of circuit breaker**||| |— usable for Standard Faults at 460/480 V according<br>to UL|Siemens type: 3VA5225, max. 250 A; Iq = 10 kA|| |**● of the fuse**||| |— usable for Standard Faults up to 575/600 V<br>accordingto UL|Type: Class RK5 / K5, max. 350 A; Iq = 10 kA|| |— usable for High Faults up to 575/600 V according to<br>UL|Type: Class J, max. 350 A; Iq = 100 kA|| |**operating power[hp] for 3-phase motors**||| |● at 200/208 V at 50 °C rated value|40 hp|| |● at 220/230 V at 50 °C rated value|40 hp|| |● at 460/480 V at 50 °C rated value|100 hp|| |Electrical Safety||| |**protection class IP on the front according to IEC 60529**|IP00; IP20 with cover|| |**touch protection on the front according to IEC 60529**|finger-safe, for vertical contact from the front with cover|| |**ATEX**||| |**Safety Integrity Level (SIL) according to IEC 61508 relating**<br>**to ATEX**|SIL 1|| |**PFHD with high demand rate according to IEC 61508**<br>**relating to ATEX**|9E-6 1/h|| |**PFDavg with low demand rate according to IEC 61508**<br>**relating to ATEX**|0.09|| |**hardware fault tolerance according to IEC 61508 relating to**<br>**ATEX**|0|| |**T1 value for proof test interval or service life according to**<br>**IEC 61508 relating to ATEX**|3 a|| |**certificate of suitability**||| |● ATEX|Yes|| |● IECEx|Yes|| |● UKEX|Yes|| |**Approvals Certificates**||| |Environmental Product Declaration||| |● global warming potential [CO2 eq] / during manufacturing<br>31.2 kg<br>● global warming potential [CO2 eq] / during sales<br>0.945 kg<br>● global warming potential [CO2 eq] / during operation<br>316 kg<br>● global warming potential [CO2 eq] / after end of life<br>-2.75 kg<br>● global warming potential [CO2 eq] / total<br>345 kg<br>**Environment**<br>**General Product Approval**|31.2 kg|| ||0.945 kg|| ||316 kg|| ||-2.75 kg|| ||345 kg|| |||**General Product Approval**| Subject to change without notice © Copyright Siemens 3RW50556AB14 Page 5/9 5/29/2026 Environmental Confirmations ~~—~~~ eee Bp © fH **General Product Approval EMV For use in hazardous locations** ce ca kk e ~~T~~ Miscellaneous **Test Certificates Maritime application other** Type Test CertificConfirmation ates/Test Report **other** Confirmation ~~-~~ QC PASS ~~OO—CsrSC“‘:CC‘isCs~~ **Further information Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RW5055-6AB14 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RW5055-6AB14 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RW5055-6AB14&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RW5055-6AB14 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **Characteristic: Tripping characteristics, I²t, Let-through current** https://support.industry.siemens.com/cs/ww/en/ps/3RW5055-6AB14/char **Characteristic: Installation altitude** https://www.automation.siemens.com/bilddb/index.aspx?gridview=view2&objkey=G_NSB0_XX_01704&showdetail=true&view=Search **Simulation Tool for Soft Starters (STS)** https://support.industry.siemens.com/cs/ww/en/view/101494917 Subject to change without notice © Copyright Siemens 3RW50556AB14 Page 6/9 5/29/2026 **==> picture [413 x 224] intentionally omitted <==** **----- Start of picture text -----**<br> -Q<br>AQ I+ AQ U+ AQ-<br>1/L1 3/L2 5/L3 A1 IN 14/24 95<br>ON/RUN BYPASSED<br>2/T1 4/T2 6/T3 A2 13 NO 23 NO 98 NO 96 NC<br>**----- End of picture text -----**<br> **last modified:** 4/4/2026 Subject to change without notice © Copyright Siemens 3RW50556AB14 Page 7/9 5/29/2026 Subject to change without notice © Copyright Siemens 3RW50556AB14 Page 8/9 5/29/2026 Subject to change without notice © Copyright Siemens 3RW50556AB14 Page 9/9 5/29/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →