3RV2711-0KD10
Thermal Magnetic Circuit Breaker, System Protection, 3RV2, 3P, 100 kA, 400 V, 1.25 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- Product Range: SIRIUS 3RV2 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 169.65 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV2711-0KD10** **Data sheet** circuit breaker frame size S00 for system protection with approval circuit breaker UL 489, CSA C22.2 no. 5-02 thermal overload release 1.25 A short-circuit release 16 A screw terminal standard switching capacity |circuit breaker frame size S00 for system protection with approval circuit breaker<br>UL 489, CSA C22.2 no. 5-02 thermal overload release 1.25 A short-circuit release<br>16 A screw terminal standard switching capacity<br>**product brand name**<br>SIRIUS<br>**product designation**<br>Circuit breaker<br>**design of theproduct**<br>For systemprotection accordingto UL 489/CSA C22.2 No. 5<br>**product type designation**<br>3RV2<br>**General technical data**<br>**Product equipment of circuit breaker for motor protection**<br>**complete unit withprotection device**<br>Yes<br>**size of the circuit-breaker**<br>S00<br>product function disconnector functionality<br>Yes<br>product extension auxiliaryswitch<br>Yes<br>**power loss[W] for rated value of the current**<br>● at AC in hot operatingstate<br>5.5 W<br>● at AC in hot operatingstateperpole<br>1.8 W<br>**type of calculation ofpower loss current-dependent**<br>quadratic<br>insulation voltage with degree ofpollution 3 at AC rated value<br>690 V<br>**surge voltage resistance rated value**<br>6 kV<br>**maximumpermissible voltage forprotective separation**<br>● in networks with ungrounded star point between main and<br>auxiliarycircuit<br>400 V<br>● in networks with grounded star point between main and<br>auxiliarycircuit<br>400 V<br>**protection class IP**<br>● on the front accordingto IEC 60529<br>IP20<br>● on the front<br>IP20<br>● of the terminal<br>IP00<br>**shock resistance according to IEC 60068-2-27**<br>25g/ 11 ms(rectangular impulse and sinepulse)<br>**mechanical service life(operating cycles)**<br>● of the main contacts typical<br>100 000<br>● of auxiliarycontacts typical<br>100 000<br>electrical endurance(operatingcycles)typical<br>100 000<br>**reference code according to IEC 81346-2**<br>Q<br>**continuous current rated value**<br>1.25 A<br>**Substance Prohibitance(day/month/year)**<br>10/01/2009<br>**SVHC substance name**<br>Lead CAS-No. 7439-92-1<br>**Net Weight**<br>490g<br>**Ambient conditions**<br>installation altitude at height above sea level maximum<br>2 000 m<br>**ambient temperature**<br>● duringoperation<br>-20 ... +60 °C<br>● duringstorage<br>-50 ... +80 °C<br>● duringtransport<br>-50 ... +80 °C<br>**temperature compensation**<br>-20 ... +60 °C<br>relative humidityduringoperation<br>10 ... 95 %<br>**Main circuit**<br>**number ofpoles for main current circuit**<br>3<br>**type of voltage for main current circuit**<br>AC<br>**operating voltage**<br>● rated value<br>690 V<br>● rated value<br>20 ... 690 V<br>Siemens~~@~~<br>EcoTech|circuit breaker frame size S00 for system protection with approval circuit breaker<br>UL 489, CSA C22.2 no. 5-02 thermal overload release 1.25 A short-circuit release<br>16 A screw terminal standard switching capacity|| |---|---|---| ||SIRIUS|| ||Circuit breaker|| ||For systemprotection accordingto UL 489/CSA C22.2 No. 5|| ||3RV2|| ||3|| ||AC|| |||| ||690 V|| ||20 ... 690 V|| Subject to change without notice © Copyright Siemens 3RV27110KD10 Page 1/5 5/30/2026 ||● at AC-3 rated value maximum|690 V|| |---|---|---|---| ||● at AC-3e rated value maximum|690 V|| ||**operating frequency rated value**|50 ... 60 Hz|| ||**operational current rated value**|1.25 A|| ||**operational current**||| ||● at AC-3 at 400 V rated value|1.25 A|| ||● at AC-3e at 400 V rated value|1.25 A|| ||**operating power**||| ||● at AC-3||| ||— at 230 V rated value|0.2 kW|| ||— at 400 V rated value|0.4 kW|| ||— at 500 V rated value|0.4 kW|| ||— at 690 V rated value|0.8 kW|| ||● at AC-3e||| ||— at 230 V rated value|0.2 kW|| ||— at 400 V rated value|0.4 kW|| ||— at 500 V rated value|0.4 kW|| ||— at 690 V rated value|0.8 kW|| ||**operating frequency**||| ||● at AC-3 maximum|15 1/h|| ||● at AC-3e maximum|15 1/h|| ||**Auxiliary circuit**||| ||**type of voltage for auxiliary and control circuit**|AC/DC|| ||**number of NC contacts for auxiliary contacts**|0|| ||**number of NO contacts for auxiliary contacts**|0|| ||number of CO contacts for auxiliarycontacts|0|| ||**Protective and monitoring functions**||| ||**product function**||| ||●ground fault detection|No|| ||●phase failure detection|No|| ||**design of the overload release**|thermal|| ||**protection function thermal overloadprotection(ANSI 49)**|Yes|| ||**maximum short-circuit current breaking capacity (Icu)**||| ||● at AC at 240 V rated value|100 kA|| ||● at AC at 400 V rated value|100 kA|| ||● at AC at 500 V rated value|100 kA|| ||● at AC at 690 V rated value|100 kA|| ||● at 480 AC Y/277 V accordingto UL 489 rated value|65 kA|| ||**operating short-circuit current breaking capacity (Ics) at AC**||| ||● at 240 V rated value|100 kA|| ||● at 400 V rated value|100 kA|| ||● at 500 V rated value|100 kA|| ||● at 690 V rated value|100 kA|| ||response value current of instantaneous short-circuit trip unit|16 A|| ||**Short-circuit protection**||| ||**product function short circuitprotection**|Yes|| ||**design of the short-circuit trip**|magnetic|| ||**design of the fuse link for IT network for short-circuit**<br>**protection of the main circuit**||| ||● at 500 V|gG 16 A|| ||● at 690 V|gG 16 A|| ||**Installation/ mounting/ dimensions**||| ||**mounting position**|any|| ||**fastening method**|screw and snap-on mountingonto 35 mm DIN rail accordingto DIN EN 60715|| ||**Mounting method of circuit breaker for Transformer**<br>**protection, Generator protection and system protection**<br>**optional standard bar mounting**|Yes|| ||**height**|144 mm|| ||**width**|45 mm|| ||**depth**|97 mm|| Subject to change without notice © Copyright Siemens 3RV27110KD10 Page 2/5 5/30/2026 ||**required spacing**||| |---|---|---|---| ||● forgroundedparts at 400 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|30 mm|| ||● for liveparts at 400 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|30 mm|| ||● forgroundedparts at 500 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|30 mm|| ||● for liveparts at 500 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|30 mm|| ||● forgroundedparts at 690 V||| ||— downwards|70 mm|| ||— upwards|70 mm|| ||— backwards|0 mm|| ||— at the side|30 mm|| ||— forwards|0 mm|| ||● for liveparts at 690 V||| ||— downwards|70 mm|| ||— upwards|70 mm|| ||— backwards|0 mm|| ||— at the side|30 mm|| ||— forwards|0 mm|| ||**Connections/ Terminals**||| ||**product component removable terminal for auxiliary and**<br>**control circuit**|No|| ||**type of electrical connection**||| ||● for main current circuit|screw-type terminals|| ||**arrangement of electrical connectors for main current**<br>**circuit**|Top and bottom|| ||**type of connectable conductor cross-sections**||| ||● for main contacts||| ||— solid or stranded|1 ... 10 mm², max. 2x 10 mm²|| ||— finelystranded with core endprocessing|1 ... 16 mm², max. 6 + 16 mm²|| ||● for AWG cables for main contacts|2x(14 ... 10)|| ||**connectable conductor cross-section for main contacts**||| ||● solid or stranded|1 ... 10 mm²|| ||● finelystranded with core endprocessing|1 ... 16 mm²|| ||**AWG number as coded connectable conductor cross**<br>**section for main contacts**|14 ... 10|| ||**tightening torque**||| ||● for main contacts with screw-type terminals|2.5 ... 3 N·m|| ||**design of screwdriver shaft**|Diameter 5 to 6 mm|| ||**size of the screwdriver tip**|Pozidriv size 2|| ||**design of the thread of the connection screw**||| ||● for main contacts|M4|| ||**Safety related data**||| ||product function suitable for safetyfunction|Yes|| ||**suitability for use**||| ||● safety-related switchingon|No|| ||● safety-related switchingOFF|Yes|| ||**service life maximum**|10 a|| ||**test wear-related service life necessary**|Yes|| ||**proportion of dangerous failures**||| Subject to change without notice © Copyright Siemens 3RV27110KD10 Page 3/5 5/30/2026 |● with low demand rate accordingto SN 31920|40 %|||||| |---|---|---|---|---|---|---| |● with high demand rate accordingto SN 31920|50 %|||||| |**B10 value with high demand rate according to SN 31920**|5 000|||||| |**failure rate [FIT] with low demand rate according to SN**|50 FIT|||||| |**31920**||||||| |ISO 13849<br>**device type according to ISO 13849-1**<br>3<br>~~ee~~||||||| |**overdimensioning according to ISO 13849-2 necessary**|Yes|||||| |IEC 61508<br>**safety device type according to IEC 61508-2**<br>Type A<br>~~a~~||||||| |**T1 value**||||||| |● for proof test interval or service life according to IEC|10 a|||||| |61508||||||| |Electrical Safety<br>**protection class IP on the front according to IEC 60529**<br>IP20<br>~~a~~||||||| |**touch protection on the front according to IEC 60529**|finger-safe, for vertical contact from the front|||er-safe, for vertical contact from the front|er-safe, for vertical contact from the front|| |**Display**<br>~~ee~~||||||| |displayversion for switchingstatus|Handle|||||| |**Approvals Certificates**<br>Environmental Product Declaration<br>~~a~~||||||| |● global warming potential [CO2 eq] / during manufacturing|1.98 kg|||||| |● global warming potential [CO2 eq] / during sales|0.134 kg|||||| |● global warming potential [CO2 eq] / during operation|72.7 kg|||||| |● global warming potential [CO2 eq] / after end of life|-0.116 kg|||||| |● global warming potential [CO2 eq] / total|74.698 kg||74.698 kg|||| |**Environment**|||**General Product Approval**|||| |Environmental Con-||||||| |firmations||||||| |**General Product Approval**||||**Test Certificates**||| |EAL<br>Cf|||UK<br>cA|Type Test Certific-<br>ates/Test Report<br>~~—_—_ ~~||Special Test Certific-<br>ate<br> ~~——~~| |**Maritime application**<br>**other**||||||| |Confirmation<br>2<br>~~-~~|||Miscellaneous<br>~~-~~||Confirmation|Miscellaneous| |Bua<br>-||||||| |**other**<br>**Railway**||||||| |Special Test Certific-<br>ate<br>**Further information**<br>~~|~~<br>QC PASS~~|~~||||||| |**Information on the packaging**||||||| |https://support.industry.siemens.com/cs/ww/en/view/109813875||||||| |**Information for data generation and storage**||||||| |https://support.industry.siemens.com/cs/ww/en/view/109995012||||||| |**Information- and Downloadcenter (Catalogs, Brochures,…)**||||||| |https://www.siemens.com/ic10||||||| |**Industry Mall (Online ordering system)**||||||| |https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2711-0KD10||||||| Subject to change without notice © Copyright Siemens 3RV27110KD10 Page 4/5 5/30/2026 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RV2711-0KD10 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2711-0KD10&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2711-0KD10 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **last modified:** 5/5/2026 Subject to change without notice © Copyright Siemens 3RV27110KD10 Page 5/5 5/30/2026
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →