Image not available
Illustrative purposes only
3RV2411-0EA20
Thermal Magnetic Circuit Breaker, XFMR Protection, 3RV2, 3P, 100 kA, 400 V, 0.4 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- Product Range: SIRIUS 3RV2 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 79.27 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV2411-0EA20** **Data sheet** Circuit breaker size S00 for transformer protection A-release 0.28...0.4 A N-release 8.2 A Spring-type terminal Standard switching capacity |Circuit breaker size S00 for transformer protection A-release 0.28...0.4 A N-release<br>8.2 A Spring-type terminal Standard switching capacity<br>**product brand name**<br>SIRIUS<br>**product designation**<br>Circuit breaker<br>**design of theproduct**<br>For transformerprotection<br>**product type designation**<br>3RV2<br>**General technical data**<br>**Product equipment of circuit breaker for motor protection**<br>**complete unit withprotection device**<br>Yes<br>**size of the circuit-breaker**<br>S00<br>**size of contactor can be combined company-specific**<br>S00, S0<br>product function disconnector functionality<br>Yes<br>product extension auxiliaryswitch<br>Yes<br>**power loss[W] for rated value of the current**<br>● at AC in hot operatingstate<br>5.5 W<br>● at AC in hot operatingstateperpole<br>1.8 W<br>**type of calculation ofpower loss current-dependent**<br>quadratic<br>insulation voltage with degree ofpollution 3 at AC rated value<br>690 V<br>**surge voltage resistance rated value**<br>6 kV<br>**maximumpermissible voltage forprotective separation**<br>● in networks with ungrounded star point between main and<br>auxiliarycircuit<br>400 V<br>● in networks with grounded star point between main and<br>auxiliarycircuit<br>400 V<br>**protection class IP**<br>● on the front accordingto IEC 60529<br>IP20<br>● on the front<br>IP20<br>● of the terminal<br>IP20<br>**shock resistance according to IEC 60068-2-27**<br>25g/ 11 ms<br>**mechanical service life(operating cycles)**<br>● of the main contacts typical<br>100 000<br>● of auxiliarycontacts typical<br>100 000<br>electrical endurance(operatingcycles)typical<br>100 000<br>**reference code according to IEC 81346-2**<br>Q<br>**continuous current rated value**<br>0.4 A<br>**Substance Prohibitance(day/month/year)**<br>10/01/2009<br>**SVHC substance name**<br>Lead CAS-No. 7439-92-1<br>**Net Weight**<br>0.299g<br>**Ambient conditions**<br>installation altitude at height above sea level maximum<br>2 000 m<br>**ambient temperature**<br>● duringoperation<br>-20 ... +60 °C<br>● duringstorage<br>-50 ... +80 °C<br>● duringtransport<br>-50 ... +80 °C<br>**temperature compensation**<br>-20 ... +60 °C<br>relative humidityduringoperation<br>10 ... 95 %<br>**Main circuit**<br>**number ofpoles for main current circuit**<br>3<br>**adjustable current response value current of the current-**<br>0.28 ... 0.4 A<br>~~|~~<br>~~|~~<br>~~|~~|Circuit breaker size S00 for transformer protection A-release 0.28...0.4 A N-release<br>8.2 A Spring-type terminal Standard switching capacity|| |---|---|---| ||SIRIUS|| ||Circuit breaker|| ||For transformerprotection|| ||3RV2|| ||3<br>~~|~~|| ||0.28 ... 0.4 A|| Subject to change without notice © Copyright Siemens 3RV24110EA20 Page 1/5 5/31/2026 ||**dependent overload release**||| |---|---|---|---| ||**type of voltage for main current circuit**|AC|| ||**operating voltage**||| ||● rated value|690 V|| ||● rated value|20 ... 690 V|| ||● at AC-3 rated value maximum|690 V|| ||● at AC-3e rated value maximum|690 V|| ||**operating frequency rated value**|50 ... 60 Hz|| ||**operational current rated value**|0.4 A|| ||**operational current**||| ||● at AC-3 at 400 V rated value|0.4 A|| ||● at AC-3e at 400 V rated value|0.4 A|| ||**operating power**||| ||● at AC-3||| ||— at 230 V rated value|0.1 kW|| ||— at 400 V rated value|0.1 kW|| ||— at 500 V rated value|0.1 kW|| ||— at 690 V rated value|0.2 kW|| ||● at AC-3e||| ||— at 230 V rated value|0.1 kW|| ||— at 400 V rated value|0.1 kW|| ||— at 500 V rated value|0.1 kW|| ||— at 690 V rated value|0.2 kW|| ||**operating frequency**||| ||● at AC-3 maximum|15 1/h|| ||● at AC-3e maximum|15 1/h|| ||**Auxiliary circuit**||| ||**type of voltage for auxiliary and control circuit**|AC/DC|| ||**number of NC contacts for auxiliary contacts**|0|| ||**number of NO contacts for auxiliary contacts**|0|| ||number of CO contacts for auxiliarycontacts|0|| ||**Protective and monitoring functions**||| ||**product function**||| ||●ground fault detection|No|| ||●phase failure detection|Yes|| ||**trip class**|CLASS 10|| ||**design of the overload release**|thermal|| ||**protection function thermal overloadprotection(ANSI 49)**|Yes|| ||**maximum short-circuit current breaking capacity (Icu)**||| ||● at AC at 240 V rated value|100 kA|| ||● at AC at 400 V rated value|100 kA|| ||● at AC at 500 V rated value|100 kA|| ||● at AC at 690 V rated value|100 kA|| ||**operating short-circuit current breaking capacity (Ics) at AC**||| ||● at 240 V rated value|100 kA|| ||● at 400 V rated value|100 kA|| ||● at 500 V rated value|100 kA|| ||● at 690 V rated value|100 kA|| ||response value current of instantaneous short-circuit trip unit|8.2 A|| ||**UL/CSA ratings**||| ||**full-load current(FLA) for 3-phase AC motor**||| ||● at 480 V rated value|0.4 A|| ||● at 600 V rated value|0.4 A|| ||**UL File Number(CCN)**|E47705(NLRV, NLRV7)|| ||**Short-circuit protection**||| ||**product function short circuitprotection**|Yes|| ||**design of the short-circuit trip**|magnetic|| ||**Installation/ mounting/ dimensions**||| ||**mounting position**|any|| Subject to change without notice © Copyright Siemens 3RV24110EA20 Page 2/5 5/31/2026 ||**fastening method**|screw and snap-on mountingonto 35 mm DIN rail accordingto DIN EN 60715|| |---|---|---|---| ||**Mounting method of circuit breaker for Transformer**<br>**protection, Generator protection and system protection**<br>**optional standard bar mounting**|Yes|| ||**height**|106 mm|| ||**width**|45 mm|| ||**depth**|97 mm|| ||**required spacing**||| ||● with side-by-side mounting||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— downwards|50 mm|| ||— at the side|0 mm|| ||● forgroundedparts||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— at the side|30 mm|| ||— downwards|50 mm|| ||● for liveparts||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— downwards|50 mm|| ||— at the side|30 mm|| ||● forgroundedparts at 400 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● for liveparts at 400 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● forgroundedparts at 500 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● for liveparts at 500 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● forgroundedparts at 690 V||| ||— downwards|50 mm|| ||— upwards|50 mm|| ||— backwards|0 mm|| ||— at the side|30 mm|| ||— forwards|0 mm|| ||● for liveparts at 690 V||| ||— downwards|50 mm|| ||— upwards|50 mm|| ||— backwards|0 mm|| ||— at the side|30 mm|| ||— forwards|0 mm|| ||**Connections/ Terminals**||| ||**product component removable terminal for auxiliary and**<br>**control circuit**|No|| ||**type of electrical connection**||| ||● for main current circuit|spring-loaded terminals|| ||**arrangement of electrical connectors for main current**|Top and bottom|| Subject to change without notice © Copyright Siemens 3RV24110EA20 Page 3/5 5/31/2026 **==> picture [512 x 607] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |circuit| |type of connectable conductor cross-sections| |● for main contacts| |— solid or stranded|2x (0,5 ... 4 mm²)| |— finely stranded with core end processing|2x (0.5 ... 2.5 mm²)| |— finely stranded without core end processing|2x (0.5 ... 2.5 mm²)| |● for AWG cables for main contacts|2x (20 ... 12)| |connectable conductor cross-section for main contacts| |● solid or stranded|0.5 ... 4 mm²| |● finely stranded with core end processing|0.5 ... 2.5 mm²| |● finely stranded without core end processing|0.5 ... 2.5 mm²| |AWG number as coded connectable conductor cross|20 ... 12| |section for main contacts| |SS|design of screwdriver shaft|Diameter 3 mm| |size of the screwdriver tip|3,0 x 0,5 mm| |Safety related data| |product function suitable for safety function|Yes| |suitability for use| |● safety-related switching on|No| |● safety-related switching OFF|Yes| |service life maximum|10 a| |test wear-related service life necessary|Yes| |proportion of dangerous failures| |● with low demand rate according to SN 31920|40 %| |● with high demand rate according to SN 31920|50 %| |B10 value with high demand rate according to SN 31920|5 000| |failure rate [FIT] with low demand rate according to SN|50 FIT| |31920| |ISO 13849| |es|device type according to ISO 13849-1|—————————————|3| |overdimensioning according to ISO 13849-2 necessary|Yes| |IEC 61508| |—|safety device type according to IEC 61508-2|Type A| |T1 value| |● for proof test interval or service life according to IEC|10 a| |61508| |Electrical Safety| |—|protection class IP on the front according to IEC 60529|IP20| |touch protection on the front according to IEC 60529|finger-safe, for vertical contact from the front| |||Display| |display version for switching status|Handle| |Approvals Certificates| |ee|Environmental Product Declaration| |● global warming potential [CO2 eq] / during manufacturing|1.98 kg| |● global warming potential [CO2 eq] / during sales|0.134 kg| |● global warming potential [CO2 eq] / during operation|72.7 kg| |● global warming potential [CO2 eq] / after end of life|-0.116 kg| |● global warming potential [CO2 eq] / total|74.698 kg| |Environment|General Product Approval| **----- End of picture text -----**<br> Environmental Confirmations ~~——~~ **General Product Approval** **Test Certificates** Subject to change without notice © Copyright Siemens 3RV24110EA20 Page 4/5 5/31/2026 - Special Test Certific ate ~~———~~ **Test Certificates Maritime application** - Type Test Certific ates/Test Report **Maritime application other Railway** ~~rs~~ Miscellaneous Confirmation Miscellaneous Confirmation **Railway** - Special Test Certific ate ~~e~~ **Further information** ~~e~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2411-0EA20 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RV2411-0EA20 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2411-0EA20&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2411-0EA20 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **last modified:** 5/5/2026 Subject to change without notice © Copyright Siemens 3RV24110EA20 Page 5/5 5/31/2026
Updated at April 27, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →