- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- Product Range: SIRIUS 3RV2 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 79.27 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV2411-0CA20** **Data sheet** Circuit breaker size S00 for transformer protection A-release 0.18...0.25 A N- release 5.2 A Spring-type terminal Standard switching capacity |**product brand name**|SIRIUS| |---|---| |**product designation**|Circuit breaker| |**design of theproduct**|For transformerprotection| |**product type designation**|3RV2| |**General technical data**|| |**Product equipment of circuit breaker for motor protection**|Yes| |**complete unit withprotection device**|| |**size of the circuit-breaker**|S00| |**size of contactor can be combined company-specific**|S00, S0| |product function disconnector functionality|Yes| |product extension auxiliaryswitch|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|5.5 W| |● at AC in hot operatingstateperpole|1.8 W| |**type of calculation ofpower loss current-dependent**|quadratic| |insulation voltage with degree ofpollution 3 at AC rated value|690 V| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● in networks with ungrounded star point between main and|400 V| |auxiliarycircuit|| |● in networks with grounded star point between main and|400 V| |auxiliarycircuit|| |**protection class IP**|| |● on the front accordingto IEC 60529|IP20| |● on the front|IP20| |● of the terminal|IP20| |**shock resistance according to IEC 60068-2-27**|25g/ 11 ms| |**mechanical service life(operating cycles)**|| |● of the main contacts typical|100 000| |● of auxiliarycontacts typical|100 000| |electrical endurance(operatingcycles)typical|100 000| |**reference code according to IEC 81346-2**|Q| |**continuous current rated value**|0.25 A| |**Substance Prohibitance(day/month/year)**|10/01/2009| |**SVHC substance name**|Lead CAS-No. 7439-92-1| |**Net Weight**|300g| |**Ambient conditions**|| |installation altitude at height above sea level maximum|2 000 m| |**ambient temperature**|| |● duringoperation|-20 ... +60 °C| |● duringstorage|-50 ... +80 °C| |● duringtransport|-50 ... +80 °C| |**temperature compensation**|-20 ... +60 °C| |relative humidityduringoperation|10 ... 95 %| |**Main circuit**|| |**number ofpoles for main current circuit**|3| |**adjustable current response value current of the current-**|0.18 ... 0.25 A| |**dependent overload release**|| |**type of voltage for main current circuit**|AC| 3RV24110CA20 Page 1/6 Subject to change without notice © Copyright Siemens 5/30/2026 ||**operating voltage**||| |---|---|---|---| ||● rated value|690 V|| ||● rated value|20 ... 690 V|| ||● at AC-3 rated value maximum|690 V|| ||● at AC-3e rated value maximum|690 V|| ||**operating frequency rated value**|50 ... 60 Hz|| ||**operational current rated value**|0.25 A|| ||**operational current**||| ||● at AC-3 at 400 V rated value|0.25 A|| ||● at AC-3e at 400 V rated value|0.25 A|| ||**operating power**||| ||● at AC-3||| ||— at 230 V rated value|0 kW|| ||— at 400 V rated value|0.1 kW|| ||— at 500 V rated value|0.1 kW|| ||— at 690 V rated value|0.1 kW|| ||● at AC-3e||| ||— at 230 V rated value|0 kW|| ||— at 400 V rated value|0.1 kW|| ||— at 500 V rated value|0.1 kW|| ||— at 690 V rated value|0.1 kW|| ||**operating frequency**||| ||● at AC-3 maximum|15 1/h|| ||● at AC-3e maximum|15 1/h|| ||**Auxiliary circuit**||| ||**type of voltage for auxiliary and control circuit**|AC/DC|| ||**number of NC contacts for auxiliary contacts**|0|| ||**number of NO contacts for auxiliary contacts**|0|| ||number of CO contacts for auxiliarycontacts|0|| ||**Protective and monitoring functions**||| ||**product function**||| ||●ground fault detection|No|| ||●phase failure detection|Yes|| ||**trip class**|CLASS 10|| ||**design of the overload release**|thermal|| ||**protection function thermal overloadprotection(ANSI 49)**|Yes|| ||**maximum short-circuit current breaking capacity (Icu)**||| ||● at AC at 240 V rated value|100 kA|| ||● at AC at 400 V rated value|100 kA|| ||● at AC at 500 V rated value|100 kA|| ||● at AC at 690 V rated value|100 kA|| ||**operating short-circuit current breaking capacity (Ics) at AC**||| ||● at 240 V rated value|100 kA|| ||● at 400 V rated value|100 kA|| ||● at 500 V rated value|100 kA|| ||● at 690 V rated value|100 kA|| ||response value current of instantaneous short-circuit trip unit|5.2 A|| ||**UL/CSA ratings**||| ||**full-load current(FLA) for 3-phase AC motor**||| ||● at 480 V rated value|0.25 A|| ||● at 600 V rated value|0.25 A|| ||**UL File Number(CCN)**|E47705(NLRV, NLRV7)|| ||**Short-circuit protection**||| ||**product function short circuitprotection**|Yes|| ||**design of the short-circuit trip**|magnetic|| ||**Installation/ mounting/ dimensions**||| ||**mounting position**|any|| ||**fastening method**|screw and snap-on mountingonto 35 mm DIN rail accordingto DIN EN 60715|| ||**Mounting method of circuit breaker for Transformer**|Yes|| 3RV24110CA20 Page 2/6 Subject to change without notice © Copyright Siemens 5/30/2026 ||**protection, Generator protection and system protection**<br>**optional standard bar mounting**||| |---|---|---|---| ||**height**|106 mm|| ||**width**|45 mm|| ||**depth**|97 mm|| ||**required spacing**||| ||● with side-by-side mounting||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— downwards|50 mm|| ||— at the side|0 mm|| ||● forgroundedparts||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— at the side|30 mm|| ||— downwards|50 mm|| ||● for liveparts||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— downwards|50 mm|| ||— at the side|30 mm|| ||● forgroundedparts at 400 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● for liveparts at 400 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● forgroundedparts at 500 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● for liveparts at 500 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● forgroundedparts at 690 V||| ||— downwards|50 mm|| ||— upwards|50 mm|| ||— backwards|0 mm|| ||— at the side|30 mm|| ||— forwards|0 mm|| ||● for liveparts at 690 V||| ||— downwards|50 mm|| ||— upwards|50 mm|| ||— backwards|0 mm|| ||— at the side|30 mm|| ||— forwards|0 mm|| ||**Connections/ Terminals**||| ||**product component removable terminal for auxiliary and**<br>**control circuit**|No|| ||**type of electrical connection**||| ||● for main current circuit|spring-loaded terminals|| ||**arrangement of electrical connectors for main current**<br>**circuit**|Top and bottom|| ||**type of connectable conductor cross-sections**||| 3RV24110CA20 Page 3/6 Subject to change without notice © Copyright Siemens 5/30/2026 **==> picture [511 x 581] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |● for main contacts| |— solid or stranded|2x (0,5 ... 4 mm²)| |— finely stranded with core end processing|2x (0.5 ... 2.5 mm²)| |— finely stranded without core end processing|2x (0.5 ... 2.5 mm²)| |● for AWG cables for main contacts|2x (20 ... 12)| |connectable conductor cross-section for main contacts| |● solid or stranded|0.5 ... 4 mm²| |● finely stranded with core end processing|0.5 ... 2.5 mm²| |● finely stranded without core end processing|0.5 ... 2.5 mm²| |AWG number as coded connectable conductor cross|20 ... 12| |section for main contacts| |re|design of screwdriver shaft|Diameter 3 mm| |size of the screwdriver tip|3,0 x 0,5 mm| |Safety related data| |product function suitable for safety function|Yes| |suitability for use| |● safety-related switching on|No| |● safety-related switching OFF|Yes| |service life maximum|10 a| |test wear-related service life necessary|Yes| |proportion of dangerous failures| |● with low demand rate according to SN 31920|40 %| |● with high demand rate according to SN 31920|50 %| |B10 value with high demand rate according to SN 31920|5 000| |failure rate [FIT] with low demand rate according to SN|50 FIT| |31920| |ISO 13849| |ee| |a|device type according to ISO 13849-1|3| |overdimensioning according to ISO 13849-2 necessary|Yes| |IEC 61508| |safety device type according to IEC 61508-2|Type A| |T1 value| |● for proof test interval or service life according to IEC|10 a| |61508| |et|Electrical Safety| |protection class IP on the front according to IEC 60529|IP20| |touch protection on the front according to IEC 60529|finger-safe, for vertical contact from the front| |a|Display| |display version for switching status|Handle| |Approvals Certificates| |es|Environmental Product Declaration| |● global warming potential [CO2 eq] / during manufacturing|1.98 kg| |● global warming potential [CO2 eq] / during sales|0.134 kg| |● global warming potential [CO2 eq] / during operation|72.7 kg| |● global warming potential [CO2 eq] / after end of life|-0.116 kg| |● global warming potential [CO2 eq] / total|74.698 kg| |Environment|General Product Approval| **----- End of picture text -----**<br> Environmental Confirmations ~~—~~ see **General Product Approval** **Test Certificates** - Special Test Certific ate 3RV24110CA20 Page 4/6 Subject to change without notice © Copyright Siemens 5/30/2026 |**Test Certificates**<br>**Maritime application**|||| |---|---|---|---| |Type Test Certific-<br>ates/Test Report<br>~~—~~@® 6||ip|| |**Maritime application**<br>**other**|||**Railway**| |Miscellaneous<br>Confirmation<br>eS ~~— —~~|Miscellaneous<br>~~~~ ~~|Ba|Confirmation| |**Railway**|||| |Special Test Certific-|||| |ate|||| |**Further information**<br>~~a~~|||| |**Information on the packaging**|||| |https://support.industry.siemens.com/cs/ww/en/view/109813875|||| |**Information for data generation and storage**|||| |https://support.industry.siemens.com/cs/ww/en/view/109995012|||| |**Information- and Downloadcenter (Catalogs, Brochures,…)**|||| |https://www.siemens.com/ic10|||| |**Industry Mall (Online ordering system)**|||| |https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2411-0CA20|||| |**Service&Support (Manuals, Certificates, Characteristics, FAQs,...)**|||| |https://support.industry.siemens.com/cs/ww/en/ps/3RV2411-0CA20|||| |**Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)**|**Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)**|**Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)**|| |https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2411-0CA20&lang=en|||| |**Cax online generator**|||| |https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2411-0CA20|||| |**Characteristic curves**|||| |https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no>|||| 3RV24110CA20 Page 5/6 Subject to change without notice © Copyright Siemens 5/30/2026 **last modified:** 5/5/2026 3RV24110CA20 Page 6/6 Subject to change without notice © Copyright Siemens 5/30/2026
Updated at April 20, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →