3RV2342-4JC10
Thermal Magnetic Circuit Breaker, SIRIUS 3RV2 Series, 63 A, 3 Pole, 690 V, DIN Rail
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type:
- No. of Poles: 3 Pole
- Product Range: SIRIUS 3RV2 Series
- Current Rating: 63A
- Voltage Rating VAC: 690V
- Voltage Rating VDC: -
- Circuit Breaker Mounting: DIN Rail
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 444.65 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV2342-4JC10**
**Data sheet**
Circuit breaker size S3 for starter combination Rated current 63 A N-release 819 A screw terminal Increased switching capacity 100 kA
|**product brand name**|SIRIUS|
|---|---|
|**product designation**|Circuit breaker|
|**design of theproduct**|For starter combinations|
|**product type designation**|3RV2|
|**General technical data**||
|**Product equipment of circuit breaker for motor protection**|Yes|
|**complete unit withprotection device**||
|**size of the circuit-breaker**|S3|
|**size of contactor can be combined company-specific**|S3|
|product function disconnector functionality|Yes|
|product extension auxiliaryswitch|Yes|
|**power loss[W] for rated value of the current**||
|● at AC in hot operatingstate|34 W|
|● at AC in hot operatingstateperpole|11.3 W|
|**type of calculation ofpower loss current-dependent**|quadratic|
|insulation voltage with degree ofpollution 3 at AC rated value|1 000 V|
|**surge voltage resistance rated value**|8 kV|
|**maximumpermissible voltage forprotective separation**||
|● in networks with ungrounded star point between main and|400 V|
|auxiliarycircuit||
|● in networks with grounded star point between main and|400 V|
|auxiliarycircuit||
|**protection class IP**||
|● on the front accordingto IEC 60529|IP20|
|● on the front|IP20|
|● of the terminal|IP00|
|**shock resistance according to IEC 60068-2-27**|25g/ 11 ms Sinus|
|**mechanical service life(operating cycles)**||
|● of the main contacts typical|25 000|
|● of auxiliarycontacts typical|25 000|
|electrical endurance(operatingcycles)typical|25 000|
|**reference code according to IEC 81346-2**|Q|
|**continuous current rated value**|63 A|
|**Substance Prohibitance(day/month/year)**|03/01/2017|
|**SVHC substance name**|Lead CAS-No. 7439-92-1|
|**Net Weight**|2.216 kg|
|**Ambient conditions**||
3RV23424JC10 Page 1/7
Subject to change without notice © Copyright Siemens
5/30/2026
||installation altitude at height above sea level maximum|2 000 m||
|---|---|---|---|
||**ambient temperature**|||
||● duringoperation|-20 ... +60 °C||
||● duringstorage|-50 ... +80 °C||
||● duringtransport|-50 ... +80 °C||
||relative humidityduringoperation|10 ... 95 %||
||**Main circuit**|||
||**number ofpoles for main current circuit**|3||
||**type of voltage for main current circuit**|AC||
||**operating voltage**|||
||● rated value|690 V||
||● rated value|20 ... 690 V||
||● at AC-3 rated value maximum|690 V||
||● at AC-3e rated value maximum|690 V||
||**operating frequency rated value**|50 ... 60 Hz||
||**operational current rated value**|63 A||
||**operational current**|||
||● at AC-3 at 400 V rated value|63 A||
||● at AC-3e at 400 V rated value|63 A||
||**operating power**|||
||● at AC-3|||
||— at 230 V rated value|18.5 kW||
||— at 400 V rated value|30 kW||
||— at 500 V rated value|37 kW||
||— at 690 V rated value|55 kW||
||● at AC-3e|||
||— at 230 V rated value|18.5 kW||
||— at 400 V rated value|30 kW||
||— at 500 V rated value|37 kW||
||— at 690 V rated value|55 kW||
||**operating frequency**|||
||● at AC-3 maximum|15 1/h||
||● at AC-3e maximum|15 1/h||
||**Auxiliary circuit**|||
||**type of voltage for auxiliary and control circuit**|AC/DC||
||**number of NC contacts for auxiliary contacts**|0||
||**number of NO contacts for auxiliary contacts**|0||
||number of CO contacts for auxiliarycontacts|0||
||**Protective and monitoring functions**|||
||**product function**|||
||●ground fault detection|No||
||●phase failure detection|No||
||**design of the overload release**|thermal||
||**protection function thermal overloadprotection(ANSI 49)**|Yes||
||**maximum short-circuit current breaking capacity (Icu)**|||
||● at AC at 240 V rated value|100 kA||
||● at AC at 400 V rated value|100 kA||
||● at AC at 500 V rated value|15 kA||
||● at AC at 690 V rated value|7.5 kA||
||**operating short-circuit current breaking capacity (Ics) at AC**|||
||● at 240 V rated value|100 kA||
||● at 400 V rated value|50 kA||
||● at 500 V rated value|7.5 kA||
||● at 690 V rated value|4 kA||
||response value current of instantaneous short-circuit trip unit|819 A||
||**UL/CSA ratings**|||
||**full-load current(FLA) for 3-phase AC motor**|||
||● at 480 V rated value|63 A||
||● at 600 V rated value|63 A||
3RV23424JC10 Page 2/7
Subject to change without notice © Copyright Siemens
5/30/2026
|**yielded mechanicalperformance[hp]**||
|---|---|
|● for single-phase AC motor||
|— at 110/120 V rated value|5 hp|
|— at 230 V rated value|15 hp|
|● for 3-phase AC motor||
|— at 200/208 V rated value|20 hp|
|— at 220/230 V rated value|25 hp|
|— at 460/480 V rated value|50 hp|
|— at 575/600 V rated value|60 hp|
|**Short-circuit protection**||
|**product function short circuitprotection**|Yes|
|**design of the short-circuit trip**|magnetic|
|**Installation/ mounting/ dimensions**||
|**mounting position**|any|
|**fastening method**|screw and snap-on mountingonto 35 mm DIN rail accordingto DIN EN 60715|
|**Mounting method of circuit breaker for Transformer**<br>**protection, Generator protection and system protection**<br>**optional standard bar mounting**|Yes|
|**height**|165 mm|
|**width**|70 mm|
|**depth**|176 mm|
|**required spacing**||
|● with side-by-side mounting||
|— forwards|0 mm|
|— backwards|0 mm|
|— upwards|150 mm|
|— downwards|150 mm|
|— at the side|0 mm|
|● forgroundedparts||
|— forwards|0 mm|
|— backwards|0 mm|
|— upwards|150 mm|
|— at the side|30 mm|
|— downwards|150 mm|
|● for liveparts||
|— forwards|0 mm|
|— backwards|0 mm|
|— upwards|150 mm|
|— downwards|150 mm|
|— at the side|30 mm|
|● forgroundedparts at 400 V||
|— downwards|70 mm|
|— upwards|70 mm|
|— at the side|10 mm|
|● for liveparts at 400 V||
|— downwards|70 mm|
|— upwards|70 mm|
|— at the side|10 mm|
|● forgroundedparts at 500 V||
|— downwards|110 mm|
|— upwards|110 mm|
|— at the side|10 mm|
|● for liveparts at 500 V||
|— downwards|110 mm|
|— upwards|110 mm|
|— at the side|10 mm|
|● forgroundedparts at 690 V||
|— downwards|150 mm|
|— upwards|150 mm|
3RV23424JC10 Page 3/7
Subject to change without notice © Copyright Siemens
5/30/2026
|— backwards|0 mm|
|---|---|
|— at the side|30 mm|
|— forwards|0 mm|
|● for liveparts at 690 V||
|— downwards|150 mm|
|— upwards|150 mm|
|— backwards|0 mm|
|— at the side|30 mm|
|— forwards|0 mm|
|**Connections/ Terminals**||
|**product component removable terminal for auxiliary and**<br>**control circuit**|No|
|**type of electrical connection**||
|● for main current circuit|screw-type terminals|
|**arrangement of electrical connectors for main current**<br>**circuit**|Top and bottom|
|**type of connectable conductor cross-sections**||
|● for main contacts||
|— solid|2x(2.5 ... 16 mm²)|
|— solid or stranded|2x(2,5 ... 50 mm²), 1x(10 ... 70 mm²)|
|— finelystranded with core endprocessing|2x(2.5 ... 35 mm²), 1x(2.5 ... 50 mm²)|
|— finelystranded without core endprocessing|2x(10 ... 35 mm²), 1x(10 ... 50 mm²)|
|**connectable conductor cross-section for main contacts**||
|● finelystranded with core endprocessing|2.5 ... 50 mm²|
|● finelystranded without core endprocessing|10 ... 50 mm²|
|**AWG number as coded connectable conductor cross**<br>**section for main contacts**|10 ... 2|
|**tightening torque**||
|● for main contacts for ringcable lug|4.5 ... 6 N·m|
|**outer diameter of the usable ring cable lug maximum**|19 mm|
|**tightening torque**||
|● for main contacts with screw-type terminals|4.5 ... 6 N·m|
|**Safety related data**||
|product function suitable for safetyfunction|Yes|
|**suitability for use**||
|● safety-related switchingon|No|
|● safety-related switchingOFF|Yes|
|**service life maximum**|10 a|
|**test wear-related service life necessary**|Yes|
|**proportion of dangerous failures**||
|● with low demand rate accordingto SN 31920|40 %|
|● with high demand rate accordingto SN 31920|50 %|
|**B10 value with high demand rate according to SN 31920**|5 000|
|**failure rate [FIT] with low demand rate according to SN**<br>**31920**|50 FIT|
|ISO 13849||
|**device type according to ISO 13849-1**|3|
|**overdimensioning according to ISO 13849-2 necessary**|Yes|
|IEC 61508||
|**safety device type according to IEC 61508-2**|Type A|
|**T1 value**||
|● for proof test interval or service life according to IEC<br>61508|10 a|
|Electrical Safety||
|**protection class IP on the front according to IEC 60529**|IP20|
|**touch protection on the front according to IEC 60529**|finger-safe, for vertical contact from the front|
|**Display**||
|displayversion for switchingstatus|Handle|
|**Approvals Certificates**||
|Environmental Product Declaration||
3RV23424JC10 Page 4/7
Subject to change without notice © Copyright Siemens
5/30/2026
|● global warming potential [CO2 eq] / during manufacturing||18.5 kg|18.5 kg||||||
|---|---|---|---|---|---|---|---|---|
|● global warming potential [CO2 eq] / during sales||1.24 kg|||||||
|● global warming potential [CO2 eq] / during operation||265 kg|||||||
|● global warming potential [CO2 eq] / after end of life||-1.5 kg|||||||
|● global warming potential [CO2 eq] / total||283.24 kg||283.24 kg|||||
|**Environment**||||**General Product Approval**|||||
|Environmental Con-<br>firmations<br>~~—~~<br>Be<br>eer©|||||||@|{G|
|**General Product Approval**||||||**Test Certificates**|||
|EAL<br>c||||Special Test Certific-<br>ate<br>Type Test Certific-<br>ates/Test Report<br> ~~cho~~|||||
|**Maritime application**|||||||||
|8||||2|||9||
|**other**||||||**Railway**|||
|Miscellaneous<br>Confirmation<br>Miscellaneous<br>Confirmation<br>Special Test Certific-<br>ate<br>~~oo~~|||||||||
|**Further information**<br>~~eC~~|||||||||
|**Information on the packaging**|||||||||
|https://support.industry.siemens.com/cs/ww/en/view/109813875|||||||||
|**Information for data generation and storage**|||||||||
|https://support.industry.siemens.com/cs/ww/en/view/109995012|||||||||
|**Information- and Downloadcenter (Catalogs, Brochures,…)**|||||||||
|https://www.siemens.com/ic10|||||||||
|**Industry Mall (Online ordering system)**|||||||||
|https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2342-4JC10|||||||||
|**Service&Support (Manuals, Certificates, Characteristics, FAQs,...)**|||||||||
|https://support.industry.siemens.com/cs/ww/en/ps/3RV2342-4JC10|||||||||
|**Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)**||||||**Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)**|||
|https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2342-4JC10&lang=en|||||||||
|**Cax online generator**|||||||||
|https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2342-4JC10|||||||||
|**Characteristic curves**|||||||||
|https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no>|||||||||
3RV23424JC10 Page 5/7
Subject to change without notice © Copyright Siemens
5/30/2026
**==> picture [263 x 335] intentionally omitted <==**
**----- Start of picture text -----**<br>
-F<br>I> I> I><br>1/L1 3/L2 5/L3<br>/T1 /T2 /T3<br>2 4 6<br>**----- End of picture text -----**<br>
**last modified:**
**==> picture [30 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
5/5/2026<br>**----- End of picture text -----**<br>
3RV23424JC10 Page 6/7
Subject to change without notice © Copyright Siemens
5/30/2026
3RV23424JC10 Page 7/7
Subject to change without notice © Copyright Siemens
5/30/2026
Updated at March 30, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →